3
-
-
79959734451
-
Fabrication and analysis of tapered tip silicon microneedles for mems based drug delivery system
-
Ashraf, M.W.; Tayyaba, S.; Afzulpurkar, N.; Nisar, A. Fabrication and analysis of tapered tip silicon microneedles for mems based drug delivery system. Sens. Transducer 2010, 122, 158-173.
-
(2010)
Sens. Transducer
, vol.122
, pp. 158-173
-
-
Ashraf, M.W.1
Tayyaba, S.2
Afzulpurkar, N.3
Nisar, A.4
-
4
-
-
77958488997
-
Design, fabrication and analysis of silicon hollow microneedles for transdermal drug delivery system for Treatment of Hemodynamic Dysfunctions Cardiovasc
-
Ashraf, M.W.; Tayyaba, S.; Nisar, A.; Afzulpurkar, N.; Bodhale, D.W.; Lomas, T.; Poyai, A.; Tuantranont, A. Design, fabrication and analysis of silicon hollow microneedles for transdermal drug delivery system for Treatment of Hemodynamic Dysfunctions Cardiovasc. Eng. J. 2010, 3, 91-108.
-
(2010)
Eng. J.
, vol.3
, pp. 91-108
-
-
Ashraf, M.W.1
Tayyaba, S.2
Nisar, A.3
Afzulpurkar, N.4
Bodhale, D.W.5
Lomas, T.6
Poyai, A.7
Tuantranont, A.8
-
7
-
-
0036705876
-
BioMEMS for drug delivery
-
Shawgo, S.R.; Amy, C.; Grayson, R.; Yawen, L. Cima, J.M. BioMEMS for drug delivery. Curr. Opin. Solid-State Mater. Sci. 2002, 6, 329-334.
-
(2002)
Curr. Opin. Solid-State Mater. Sci.
, vol.6
, pp. 329-334
-
-
Shawgo, S.R.1
Amy, C.2
Grayson, R.3
Yawen, L.4
Cima, J.M.5
-
8
-
-
1642534297
-
Electronic MEMS for triggered delivery
-
Amy, C.; Grayson, R.; Shawgo, R.S.; Li, Y.; Cima, M.J. Electronic MEMS for triggered delivery. Adv. Drug Deliv. Rev. 2004, 56, 173-184.
-
(2004)
Adv. Drug Deliv. Rev.
, vol.56
, pp. 173-184
-
-
Amy, C.1
Grayson, R.2
Shawgo, R.S.3
Li, Y.4
Cima, M.J.5
-
9
-
-
33646862381
-
Application of micro and nano electromechanical devices to drug delivery
-
Staples, M.; Daniel, K.; Cima, M.J.; Langer, R. Application of micro and nano electromechanical devices to drug delivery. Pharm. Res. 2006, 23, 847-863.
-
(2006)
Pharm. Res.
, vol.23
, pp. 847-863
-
-
Staples, M.1
Daniel, K.2
Cima, M.J.3
Langer, R.4
-
11
-
-
13244251242
-
Micropumps-past, progress and future prospects
-
Woias, P. Micropumps-past, progress and future prospects. Sens. Actuators B 2005, 105, 28-38.
-
(2005)
Sens. Actuators B
, vol.105
, pp. 28-38
-
-
Woias, P.1
-
12
-
-
33847359977
-
Review of MEMS based drug delivery and dosing systems
-
Tsai, N.C.; Sue, C.Y. Review of MEMS based drug delivery and dosing systems. Sens. Actuators A 2007, 134, 555-564.
-
(2007)
Sens. Actuators A
, vol.134
, pp. 555-564
-
-
Tsai, N.C.1
Sue, C.Y.2
-
13
-
-
41249087117
-
MEMS-based micropumps in drug delivery and biomedical applications
-
Nisar, A.; Afzulpurkar, N.; Mahaisavariya, B.; Tuantranont, A. MEMS-based micropumps in drug delivery and biomedical applications. Sens. Actuators B 2008, 130, 917-942.
-
(2008)
Sens. Actuators B
, vol.130
, pp. 917-942
-
-
Nisar, A.1
Afzulpurkar, N.2
Mahaisavariya, B.3
Tuantranont, A.4
-
14
-
-
62249096225
-
Current micropump technologies and their biomedical applications
-
Amirouche, F.; Zhou, Y.; Johnson. T. Current micropump technologies and their biomedical applications. Microsyst. Technol. 2009, 15, 647-666.
-
(2009)
Microsyst. Technol.
, vol.15
, pp. 647-666
-
-
Amirouche, F.1
Zhou, Y.2
Johnson, T.3
-
15
-
-
11144236389
-
A BioMEMS review: MEMS technology for physiologically integrated devices
-
Grayson, A.R.; Shawgo, R.S.; Johnson, A.M.; Flynn, N.T.; Yawen, L.; Cima, M.J.; Langer, R. A BioMEMS review: MEMS technology for physiologically integrated devices. Proc. IEEE 2004, 92, 6-21.
-
(2004)
Proc. IEEE
, vol.92
, pp. 6-21
-
-
Grayson, A.R.1
Shawgo, R.S.2
Johnson, A.M.3
Flynn, N.T.4
Yawen, L.5
Cima, M.J.6
Langer, R.7
-
16
-
-
79959762928
-
A review of MEMS drug delivery in medical application, Biomed 06
-
Karman, S.; Ibrahim, F.; Soin, N. A review of MEMS drug delivery in medical application, Biomed 06. Proc. IFMBE 2007, 15, 312-315.
-
(2007)
Proc. IFMBE
, vol.15
, pp. 312-315
-
-
Karman, S.1
Ibrahim, F.2
Soin, N.3
-
17
-
-
79959728841
-
An review of MEMS-Based microneedles technology developments
-
doi:1671-4776.0.2005-04-002
-
Bao-jian, X.; Qing-hui, J.; Jian-long, Z. An review of MEMS-Based microneedles technology developments. Micronanoelectron. Technol. 2005, 4, doi:1671-4776.0.2005-04-002.
-
(2005)
Micronanoelectron. Technol.
, vol.4
-
-
Bao-jian, X.1
Qing-hui, J.2
Jian-long, Z.3
-
18
-
-
77952331272
-
Microneedle-Based Automated Therapy for Diabetes Mellitus
-
Khanna, P.; Storm, J.A.; Malone, J.I.; Bhansali, S. Microneedle-Based Automated Therapy for Diabetes Mellitus. J. Diabetes Sci. Technol. 2008, 2, 1122-1129.
-
(2008)
J. Diabetes Sci. Technol.
, vol.2
, pp. 1122-1129
-
-
Khanna, P.1
Storm, J.A.2
Malone, J.I.3
Bhansali, S.4
-
20
-
-
0027695246
-
A valveless diffuser/nozzle based fluid pump
-
Stemme, E.; Stemme, G. A valveless diffuser/nozzle based fluid pump. Sens. Actuators A 1993, 39, 159-167.
-
(1993)
Sens. Actuators A
, vol.39
, pp. 159-167
-
-
Stemme, E.1
Stemme, G.2
-
21
-
-
0038038662
-
-
McGraw Hill Inc.: Columbus, OH, USA
-
White, F.M. Fluid Mechanics, International Student Edition; McGraw Hill Inc.: Columbus, OH, USA, 1979; pp. 161-162.
-
(1979)
Fluid Mechanics, International Student Edition
, pp. 161-162
-
-
White, F.M.1
-
22
-
-
0024101674
-
A piezoelectric micropump based on micromachining of silicon
-
Van Lintel, H.T.G.; Van de Pol, F.C.M.; Bouwstra, S. A piezoelectric micropump based on micromachining of silicon. Sens. Actuators A 1988, 15, 153-168.
-
(1988)
Sens. Actuators A
, vol.15
, pp. 153-168
-
-
van Lintel, H.T.G.1
van de Pol, F.C.M.2
Bouwstra, S.3
-
23
-
-
0024860591
-
Normally close microvalve and micropump fabricated on a silicon wafer
-
In, Salt Lake City, UT, USA, 20-22 February
-
Esashi, M.; Shoji, S.; Nakano, A. Normally close microvalve and micropump fabricated on a silicon wafer. In Proceedings of IEEE Micro Electro Mechanical Systems, An Investigation of Micro Structures, Sensors, Actuators Machines and Robots, Salt Lake City, UT, USA, 20-22 February 1989; pp. 29-34.
-
(1989)
Proceedings of IEEE Micro Electro Mechanical Systems, An Investigation of Micro Structures, Sensors, Actuators Machines and Robots
, pp. 29-34
-
-
Esashi, M.1
Shoji, S.2
Nakano, A.3
-
24
-
-
0029275289
-
A valve-less planar fluid pump with two pump chambers, Sens
-
Olsson, A.; Stemme, G.; Stemme, E. A valve-less planar fluid pump with two pump chambers, Sens. Actuators A 1995, 47, 549-556.
-
(1995)
Actuators A
, vol.47
, pp. 549-556
-
-
Olsson, A.1
Stemme, G.2
Stemme, E.3
-
25
-
-
0042638062
-
A novel micromachined pump based on thick film piezoelectric actuation
-
Koch, M.; Harris, N.; Evans, A.G.R.; White, N.M.; Brunnschweiler, A. A novel micromachined pump based on thick film piezoelectric actuation. Sens. Actuators A 1998, 70, 98-103.
-
(1998)
Sens. Actuators A
, vol.70
, pp. 98-103
-
-
Koch, M.1
Harris, N.2
Evans, A.G.R.3
White, N.M.4
Brunnschweiler, A.5
-
26
-
-
0036646584
-
Self-aligning gas/liquid micropump
-
Schabmueller, C.G.J.; Koch, M.; Mokhtari, M.E.; Evans, A.G.R.; Brunnschweiler, A.; Sehr, H. Self-aligning gas/liquid micropump. J. Micromech. Microeng. 2002, 12, 420-424.
-
(2002)
J. Micromech. Microeng.
, vol.12
, pp. 420-424
-
-
Schabmueller, C.G.J.1
Koch, M.2
Mokhtari, M.E.3
Evans, A.G.R.4
Brunnschweiler, A.5
Sehr, H.6
-
27
-
-
18844370104
-
Piezoelectrically actuated dome-shaped diaphragm micropump
-
Feng, G.H.; Kim, E.S. Piezoelectrically actuated dome-shaped diaphragm micropump. J. Microelectromech. Syst. 2005, 14, 92-199.
-
(2005)
J. Microelectromech. Syst.
, vol.14
, pp. 92-199
-
-
Feng, G.H.1
Kim, E.S.2
-
28
-
-
33750098742
-
Pressure independent micropump with piezoelectric valves for low flow drug delivery systems
-
In, Istanbul, Turkey, 22-26 January
-
Geipel, A.; Doll, A.; Goldschmidtboing, F.; Jantscheff, P.; Esser, N.; Massing, U.; Woias, P. Pressure independent micropump with piezoelectric valves for low flow drug delivery systems. In Proceedings of 19th IEEE International Conference on Micro Electro Mechanical Systems, 2006, Istanbul, Turkey, 22-26 January 2006; pp. 786-789.
-
(2006)
Proceedings of 19th IEEE International Conference on Micro Electro Mechanical Systems, 2006
, pp. 786-789
-
-
Geipel, A.1
Doll, A.2
Goldschmidtboing, F.3
Jantscheff, P.4
Esser, N.5
Massing, U.6
Woias, P.7
-
29
-
-
71549161129
-
Normally-closed peristaltic micropump with re-usable actuator and disposable fluidic chip
-
Trenkle, F.; Haeberle, S.; Zengerle, R. Normally-closed peristaltic micropump with re-usable actuator and disposable fluidic chip. Procedia Chem. 2009, 1, 1515-1518.
-
(2009)
Procedia Chem.
, vol.1
, pp. 1515-1518
-
-
Trenkle, F.1
Haeberle, S.2
Zengerle, R.3
-
30
-
-
73549091972
-
Piezoeletric Micropump for Drug Delivery System Fabricated Using Two Optical Masks
-
Johari, J.; Yunas, J.; Yeopmajlis, B. Piezoeletric Micropump for Drug Delivery System Fabricated Using Two Optical Masks. Adv. Mat. Res. 2009, 74, 279-282.
-
(2009)
Adv. Mat. Res.
, vol.74
, pp. 279-282
-
-
Johari, J.1
Yunas, J.2
Yeopmajlis, B.3
-
31
-
-
71749118966
-
Asymmetrical flow effect applied to pumping performance of simple duct channel
-
Wang, C.; Leu, T.; Sun, J. Asymmetrical flow effect applied to pumping performance of simple duct channel. Sens. Actuators A 2009, 155, 203-209.
-
(2009)
Sens. Actuators A
, vol.155
, pp. 203-209
-
-
Wang, C.1
Leu, T.2
Sun, J.3
-
32
-
-
77956262633
-
A dynamic piezoelectric micropumping phenomenon
-
Ali, M. Y.; Kuang, C.; Khan, J.; Wang, G. A dynamic piezoelectric micropumping phenomenon. Microfluid. Nanofluid. 2010, 9, 385-396.
-
(2010)
Microfluid. Nanofluid.
, vol.9
, pp. 385-396
-
-
Ali, M.Y.1
Kuang, C.2
Khan, J.3
Wang, G.4
-
33
-
-
77957653051
-
A disposable piezoelectric micropump with high performance for closed-loop insulin therapy system
-
Liu, G.; Shen, C.; Yang, Z.; Cai, X.; Zhang, H. A disposable piezoelectric micropump with high performance for closed-loop insulin therapy system. Sens. Actuators A 2010, 163, 291-296.
-
(2010)
Sens. Actuators A
, vol.163
, pp. 291-296
-
-
Liu, G.1
Shen, C.2
Yang, Z.3
Cai, X.4
Zhang, H.5
-
34
-
-
0025807422
-
Surface-machined Micromechanical Membrane Pump
-
In, Nara, Japan, 30 January-2 February
-
Judy, J.W.; Tamagawa, T.; Polla, D.L. Surface-machined Micromechanical Membrane Pump. In Proceedings of the IEEE Micro Electro Mechanical systems, Nara, Japan, 30 January-2 February 1991; pp. 182-186.
-
(1991)
Proceedings of the IEEE Micro Electro Mechanical systems
, pp. 182-186
-
-
Judy, J.W.1
Tamagawa, T.2
Polla, D.L.3
-
35
-
-
0027041292
-
A Micro Membrane Pump with Electrostatic Actuation
-
In, Travemunde, Germany, 4-7 February
-
Zengerle, R.; Richter, A.; Sandmaier, H. A Micro Membrane Pump with Electrostatic Actuation. In Proceedings of Micro Electro Mechanical Systems 1992, An Investigation of Micro Structures, Sensors, Actuators, Machines and Robot. IEEE, Travemunde, Germany, 4-7 February 1992; pp. 19-24.
-
(1992)
Proceedings of Micro Electro Mechanical Systems 1992, An Investigation of Micro Structures, Sensors, Actuators, Machines and Robot. IEEE
, pp. 19-24
-
-
Zengerle, R.1
Richter, A.2
Sandmaier, H.3
-
36
-
-
0034998412
-
The dual diaphragm pump
-
In, Interlaken, Switzerland, 21-25 January
-
Cabuz, C.; Herb, W.R.; Cabuz, E.I.; Lu, S.T. The dual diaphragm pump. In Proceedings of the 14th IEEE International Conference on Micro Electro Mechanical Systems, Interlaken, Switzerland, 21-25 January 2001; pp. 519-522.
-
(2001)
Proceedings of the 14th IEEE International Conference on Micro Electro Mechanical Systems
, pp. 519-522
-
-
Cabuz, C.1
Herb, W.R.2
Cabuz, E.I.3
Lu, S.T.4
-
37
-
-
27944476693
-
A membrane micropump electrostatically actuated across the working fluid
-
Machauf, A.; Nemirovsky, Y.; Dinnar, U. A membrane micropump electrostatically actuated across the working fluid. J. Micromech. Microeng. 2005, 15, 2309-2316.
-
(2005)
J. Micromech. Microeng.
, vol.15
, pp. 2309-2316
-
-
McHauf, A.1
Nemirovsky, Y.2
Dinnar, U.3
-
38
-
-
33847291851
-
Theoretical and experimental performance of a high frequency gas micropump
-
Astle, A.A.; Kim, H.S.; Bernal, L.P.; Najafi, K.; Washabaugh, P.D. Theoretical and experimental performance of a high frequency gas micropump. Sens. Actuators A 2006, 134, 245-256.
-
(2006)
Sens. Actuators A
, vol.134
, pp. 245-256
-
-
Astle, A.A.1
Kim, H.S.2
Bernal, L.P.3
Najafi, K.4
Washabaugh, P.D.5
-
39
-
-
79959768591
-
Adaptive gas pumping by colntrolled timing of active microvalves in peristaltic micropumps
-
In, Denver, CO, USA, 21-25 June
-
Lee, S.; Yee, S.Y.; Besharatian, A.; Kim, H.; Bernal, L.P.; Najafi, K. Adaptive gas pumping by colntrolled timing of active microvalves in peristaltic micropumps. In Proceedings of Transducers, Denver, CO, USA, 21-25 June 2009.
-
(2009)
Proceedings of Transducers
-
-
Lee, S.1
Yee, S.Y.2
Besharatian, A.3
Kim, H.4
Bernal, L.P.5
Najafi, K.6
-
41
-
-
77957949799
-
Modeling of a Micropump Membrane with Electrostatic Actuator
-
In, Shenyang, China, 27-29 March
-
Lil., L.; Zhu, R.; Zhou, Z.; Ren, J. Modeling of a Micropump Membrane with Electrostatic Actuator. In Proceedings of 2nd International Conference on Advanced Computer Control (ICACC), Shenyang, China, 27-29 March 2010.
-
(2010)
Proceedings of 2nd International Conference on Advanced Computer Control (ICACC)
-
-
Lil, L.1
Zhu, R.2
Zhou, Z.3
Ren, J.4
-
42
-
-
0025698116
-
A thermopneumatic micropump based on microengineering techniques
-
Van de Pol, F.C.M.; van Lintel, H.T.G.; Elwenspoek, M.; Fluitman, J.H.J. A thermopneumatic micropump based on microengineering techniques. Sens. Actuators A 1990, 21, 198-202.
-
(1990)
Sens. Actuators A
, vol.21
, pp. 198-202
-
-
van de Pol, F.C.M.1
van Lintel, H.T.G.2
Elwenspoek, M.3
Fluitman, J.H.J.4
-
43
-
-
0033741496
-
Fabrication and test of a thermopneumatic micropump with a corrugated p diaphragm, Sens
-
Jeong, O.C.; Yang, S.S. Fabrication and test of a thermopneumatic micropump with a corrugated p diaphragm, Sens. Actuators 2000, 83, 249-255.
-
(2000)
Actuators
, vol.83
, pp. 249-255
-
-
Jeong, O.C.1
Yang, S.S.2
-
44
-
-
4544257923
-
A thermopneumatic dispensing micropump
-
Cooney, C.G.; Towe, B.C. A thermopneumatic dispensing micropump. Sens. Actuators A 2004, 116, 519-524.
-
(2004)
Sens. Actuators A
, vol.116
, pp. 519-524
-
-
Cooney, C.G.1
Towe, B.C.2
-
45
-
-
17644400484
-
A disposable thermopneumatic actuated micropump stacked with PDMS layers and ITO coated glass, Sens
-
Kim, J.H.; Na, K.H.; Kang, C.J.; Kim, Y.S. A disposable thermopneumatic actuated micropump stacked with PDMS layers and ITO coated glass, Sens. Actuators A 2005, 120, 365-369.
-
(2005)
Actuators A
, vol.120
, pp. 365-369
-
-
Kim, J.H.1
Na, K.H.2
Kang, C.J.3
Kim, Y.S.4
-
46
-
-
42549148752
-
Fabrication of a peristaltic micro pump with novel cascaded actuators
-
Jeong, O.C.; Konishi, S. Fabrication of a peristaltic micro pump with novel cascaded actuators. J. Micromech. Microeng. 2008, 18, 025022.
-
(2008)
J. Micromech. Microeng.
, vol.18
, pp. 025022
-
-
Jeong, O.C.1
Konishi, S.2
-
47
-
-
79951773017
-
A novel thermo-pneumatic peristaltic micropump with low temperature elevation on working fluid
-
Chia, B.T.; Liao, H.; Yang, Y. A novel thermo-pneumatic peristaltic micropump with low temperature elevation on working fluid. Sens. Actuators A 2010, 165, 86-93.
-
(2010)
Sens. Actuators A
, vol.165
, pp. 86-93
-
-
Chia, B.T.1
Liao, H.2
Yang, Y.3
-
48
-
-
78049416195
-
A reliable method for bonding polydimethylsiloxane (PDMS) to polymethylmethacrylate (PMMA) and its application in micropumps
-
Tan, H.Y.; Loke, W.K.; Nguyen, N. A reliable method for bonding polydimethylsiloxane (PDMS) to polymethylmethacrylate (PMMA) and its application in micropumps. Sens. Actuators B 2010, 151, 133-139.
-
(2010)
Sens. Actuators B
, vol.151
, pp. 133-139
-
-
Tan, H.Y.1
Loke, W.K.2
Nguyen, N.3
-
49
-
-
0000115145
-
A Bi-directional Magnetic Micropump on a Silicon Wafer
-
In, Hilton Head Island, SC, USA, 3-6 June
-
Zheng, W.; Ahn, C.H. A Bi-directional Magnetic Micropump on a Silicon Wafer. In Proceedings of Technical Digest Solid-State Sensor and Actuator Workshop 1996, Hilton Head Island, SC, USA, 3-6 June 1996.
-
(1996)
Proceedings of Technical Digest Solid-State Sensor and Actuator Workshop 1996
-
-
Zheng, W.1
Ahn, C.H.2
-
50
-
-
0141907969
-
A plastic micropump constructed with conventional techniques and materials
-
Bohm, S.; Olthuis, W.; Bergveld, P. A plastic micropump constructed with conventional techniques and materials. Sens. Actuators A 1999, 77, 223-228.
-
(1999)
Sens. Actuators A
, vol.77
, pp. 223-228
-
-
Bohm, S.1
Olthuis, W.2
Bergveld, P.3
-
51
-
-
0033731832
-
Design, optimization and simulation on microelectromagnetic pump
-
Gong, Q.; Zhou, Z.; Yang, Y.; Wang, X. Design, optimization and simulation on microelectromagnetic pump. Sens. Actuators A 2000, 83, 200-207.
-
(2000)
Sens. Actuators A
, vol.83
, pp. 200-207
-
-
Gong, Q.1
Zhou, Z.2
Yang, Y.3
Wang, X.4
-
52
-
-
22244473350
-
A PMMA valveless micropump using electromagnetic actuation
-
Yamahata, C.; Lotto, C.; Al Assaf, E.; Gijs, M.A.M. A PMMA valveless micropump using electromagnetic actuation. Microfluid. Nanofluid. 2005, 1, 197-207.
-
(2005)
Microfluid. Nanofluid.
, vol.1
, pp. 197-207
-
-
Yamahata, C.1
Lotto, C.2
Al Assaf, E.3
Gijs, M.A.M.4
-
53
-
-
28344441846
-
Analysis and fabrication process of an electromagnetically actuated valveless micropump with two parallel flexible diaphragms
-
Su, Y.; Chen, W.; Cui, F.; Zhang, W. Analysis and fabrication process of an electromagnetically actuated valveless micropump with two parallel flexible diaphragms. Proc. IMechE 2005, 219, 1007-1014.
-
(2005)
Proc. IMechE
, vol.219
, pp. 1007-1014
-
-
Su, Y.1
Chen, W.2
Cui, F.3
Zhang, W.4
-
54
-
-
33744505794
-
Electro-magnetically Actuated Minute Polymer Pump Fabricated using Packaging Technology
-
Balaji, G.; Singh, S.; Ananthasuresh, G.K. Electro-magnetically Actuated Minute Polymer Pump Fabricated using Packaging Technology. J. Phys. 2006, 34, 258-263.
-
(2006)
J. Phys.
, vol.34
, pp. 258-263
-
-
Balaji, G.1
Singh, S.2
Ananthasuresh, G.K.3
-
55
-
-
34547335027
-
Design and fabrication process of electromagnetically actuated valveless micropump with two parallel flexible diaphragms
-
Yu-feng, S.U.; Wen-yuan, C.; Feng, C.; Wei-ping, Z. Design and fabrication process of electromagnetically actuated valveless micropump with two parallel flexible diaphragms. J. Shanghai Univ. 2007, 11, 79-83.
-
(2007)
J. Shanghai Univ.
, vol.11
, pp. 79-83
-
-
Yu-feng, S.U.1
Wen-yuan, C.2
Feng, C.3
Wei-ping, Z.4
-
56
-
-
44149097421
-
Miniaturized PMMA ball-valve micropump with cylindrical electromagnetic actuator
-
Shen, M.; Yamahata, C.; Gijs, M.A.M. Miniaturized PMMA ball-valve micropump with cylindrical electromagnetic actuator. Microelectr. Eng. 2008, 85, 1104-1107.
-
(2008)
Microelectr. Eng.
, vol.85
, pp. 1104-1107
-
-
Shen, M.1
Yamahata, C.2
Gijs, M.A.M.3
-
57
-
-
77957153529
-
Development of a novel electromagnetic pump for biomedical applications
-
Al-Halhouli, A.T.; Kilani, M.I.; Büttgenbacha, S. Development of a novel electromagnetic pump for biomedical applications. Sens. Actuators A 2010, 162, 172-176.
-
(2010)
Sens. Actuators A
, vol.162
, pp. 172-176
-
-
Al-Halhouli, A.T.1
Kilani, M.I.2
Büttgenbacha, S.3
-
58
-
-
33845905561
-
A silicon membrane micropump with integrated bimetallic actuator
-
Zhan, C.; Lo, T.; Liu, L.P. A silicon membrane micropump with integrated bimetallic actuator. Chin. J. Electron. 1996, 5, 29-35.
-
(1996)
Chin. J. Electron.
, vol.5
, pp. 29-35
-
-
Zhan, C.1
Lo, T.2
Liu, L.P.3
-
59
-
-
0013445574
-
A Novel Thermally Actuated Silicon Micropump
-
In, Nagoya, Japan, 5-8 October
-
Zou, J.X.; Ye, Y.Z.; Zhou, Y.; Yang, Y. A Novel Thermally Actuated Silicon Micropump. In Proceedings of International Symposium on Micromechatronics and Human Science, Nagoya, Japan, 5-8 October 1997.
-
(1997)
Proceedings of International Symposium on Micromechatronics and Human Science
-
-
Zou, J.X.1
Ye, Y.Z.2
Zhou, Y.3
Yang, Y.4
-
60
-
-
0032226793
-
The Study of Single Chip Integrated Microfluidic System
-
In, Beijing, China, 21-23 October
-
Pang, J.; Zou, Q.; Tan, Z.; Qian, X.; Liu, L.; Li, Z. The Study of Single Chip Integrated Microfluidic System. In Proceedings of 5th International Conference on Solid State and Integrated Circuit Technology, Beijing, China, 21-23 October 1998; pp. 895-898.
-
(1998)
Proceedings of 5th International Conference on Solid State and Integrated Circuit Technology
, pp. 895-898
-
-
Pang, J.1
Zou, Q.2
Tan, Z.3
Qian, X.4
Liu, L.5
Li, Z.6
-
61
-
-
79959767770
-
Bimetallic Thermally Actuated Micropump
-
In, Atlanta, GA, USA, 17-22 November
-
Yang, Y.; Zhaoying, Z.; Xiongying, Y.; Xiaoning, J. Bimetallic Thermally Actuated Micropump. In Proceedings of International Mechnical Engineering Congross and Exposition (ASME 1996), Atlanta, GA, USA, 17-22 November 1996.
-
(1996)
Proceedings of International Mechnical Engineering Congross and Exposition (ASME 1996)
-
-
Yang, Y.1
Zhaoying, Z.2
Xiongying, Y.3
Xiaoning, J.4
-
62
-
-
0030381989
-
Design and Experiments of Micropump Using ICPF Actuator
-
In, Nagoya, Japan, 2-4 October
-
Guo, S.; Nakamura, T.; Fukuda, T.; Oguro, K. Design and Experiments of Micropump Using ICPF Actuator. In Proceedings of 7th International IEEE Symposium on Micro Machine and Human Science, Nagoya, Japan, 2-4 October 1996; pp. 235-240.
-
(1996)
Proceedings of 7th International IEEE Symposium on Micro Machine and Human Science
, pp. 235-240
-
-
Guo, S.1
Nakamura, T.2
Fukuda, T.3
Oguro, K.4
-
63
-
-
0032655715
-
Soft Micromanipulation Device with Multiple Degrees of Freedom Consisting of High Polymer Gel Actuators
-
In, Orlando, FL, USA, 17-21 January
-
Tadokoro, S.; Yamagami, S.; Ozawa, M. Soft Micromanipulation Device with Multiple Degrees of Freedom Consisting of High Polymer Gel Actuators. In Proceedings of IEEE International Conference on Microelectromechanical Systems, Orlando, FL, USA, 17-21 January 1999; pp. 37-42.
-
(1999)
Proceedings of IEEE International Conference on Microelectromechanical Systems
, pp. 37-42
-
-
Tadokoro, S.1
Yamagami, S.2
Ozawa, M.3
-
64
-
-
0344014253
-
Polymer Based New Type of Micropump for Biomedical Applications
-
In, Taipei, Taiwan, 14-19 September
-
Guo, S.; Asaka, K. Polymer Based New Type of Micropump for Biomedical Applications. In Proceedings of IEEE Conference on Robotics & Automation, Taipei, Taiwan, 14-19 September 2003; pp. 1830-1835.
-
(2003)
Proceedings of IEEE Conference on Robotics & Automation
, pp. 1830-1835
-
-
Guo, S.1
Asaka, K.2
-
65
-
-
38149053640
-
Design, fabrication, and experimental characterization of a flap valve IPMC micropump with a flexibly supported diaphragm
-
Nguyen, T.T.; Goo, N.S.; Nguyen, V.K.; Yoo, Y.; Park, S. Design, fabrication, and experimental characterization of a flap valve IPMC micropump with a flexibly supported diaphragm. Sens. Actuators A 2008, 141, 640-648.
-
(2008)
Sens. Actuators A
, vol.141
, pp. 640-648
-
-
Nguyen, T.T.1
Goo, N.S.2
Nguyen, V.K.3
Yoo, Y.4
Park, S.5
-
66
-
-
43549084778
-
Integrated IMPC/PVDF sensory actuator and its validation in feedback control
-
Chen, Z.; Kwon, K.; Tan, X. Integrated IMPC/PVDF sensory actuator and its validation in feedback control. Sens. Actuators A 2008, 144, 231-241.
-
(2008)
Sens. Actuators A
, vol.144
, pp. 231-241
-
-
Chen, Z.1
Kwon, K.2
Tan, X.3
-
67
-
-
76349085171
-
A novel diaphragm micropump actuated by conjugated polymer petals: Fabrication, modeling, and experimental results
-
Fang, T.; Tan, X. A novel diaphragm micropump actuated by conjugated polymer petals: Fabrication, modeling, and experimental results. Sens. Actuators A 2010, 158, 121-131.
-
(2010)
Sens. Actuators A
, vol.158
, pp. 121-131
-
-
Fang, T.1
Tan, X.2
-
68
-
-
0037340987
-
A phase change type of micropump with aluminum flap valves
-
Sim, W.Y.; Yoon, H.J.; Jeong, O.C.; Yang, S.S. A phase change type of micropump with aluminum flap valves. J. Micromech. Microeng. 2003, 13, 286-294.
-
(2003)
J. Micromech. Microeng.
, vol.13
, pp. 286-294
-
-
Sim, W.Y.1
Yoon, H.J.2
Jeong, O.C.3
Yang, S.S.4
-
69
-
-
27544440977
-
A Polymeric Paraffin Micropump with Active Valves for High Pressure Microfluidics
-
In, Seoul, Korea, 5-9 June
-
Boden, R.; Lehto, M.; Simu, U.; Thornell, G.; Hjort, K.; Schweitz, J.A. A Polymeric Paraffin Micropump with Active Valves for High Pressure Microfluidics. In Proceedings of 13th International Conference on Solid State Sensors, Actuators and Microsystems, Seoul, Korea, 5-9 June 2005; pp. 201-204.
-
(2005)
Proceedings of 13th International Conference on Solid State Sensors, Actuators and Microsystems
, pp. 201-204
-
-
Boden, R.1
Lehto, M.2
Simu, U.3
Thornell, G.4
Hjort, K.5
Schweitz, J.A.6
-
71
-
-
0032099409
-
Thin-film shapememory alloy actuated micropumps
-
Benard, W.L.; Kahn, H.; Heuer, A.H.; Huff, M.A. Thin-film shapememory alloy actuated micropumps. J. Microelectromech. Syst. 1998, 7, 245-251.
-
(1998)
J. Microelectromech. Syst.
, vol.7
, pp. 245-251
-
-
Benard, W.L.1
Kahn, H.2
Heuer, A.H.3
Huff, M.A.4
-
72
-
-
0034833238
-
Fabrication of TiNi shape memory micropump
-
Makino, E.; Mitsuya, T.; Shibata, T. Fabrication of TiNi shape memory micropump. Sens. Actuators A 2001, 88, 256-262.
-
(2001)
Sens. Actuators A
, vol.88
, pp. 256-262
-
-
Makino, E.1
Mitsuya, T.2
Shibata, T.3
-
73
-
-
0035948960
-
Characteristics and fabrication of NiTi/Si diaphragm micropump
-
Xu, D.; Wang, L.; Ding, G.; Zhou, Y.; Yu, A.; Cai, B. Characteristics and fabrication of NiTi/Si diaphragm micropump. Sens. Actuators A 2001, 93, 87-92.
-
(2001)
Sens. Actuators A
, vol.93
, pp. 87-92
-
-
Xu, D.1
Wang, L.2
Ding, G.3
Zhou, Y.4
Yu, A.5
Cai, B.6
-
74
-
-
3042678975
-
SMA Actuator Based Novel Type of Micropump for Biomedical Application
-
In, Takamatsu, Japan, 26 April-1 May
-
Shuxiang, G.; Fukuda, T. SMA Actuator Based Novel Type of Micropump for Biomedical Application. In Proceedings of IEEE International Conference Robotics and Automation, Takamatsu, Japan, 26 April-1 May 2004; Volume 2, pp. 1616-1621.
-
(2004)
Proceedings of IEEE International Conference Robotics and Automation
, vol.2
, pp. 1616-1621
-
-
Shuxiang, G.1
Fukuda, T.2
-
75
-
-
33646835775
-
A TiNiCu thin film micropump made by magnetron Co-sputtered method
-
Zhang, H.J.; Qiu, C.J. A TiNiCu thin film micropump made by magnetron Co-sputtered method. Mat. Trans. 2006, 47, 532-535.
-
(2006)
Mat. Trans.
, vol.47
, pp. 532-535
-
-
Zhang, H.J.1
Qiu, C.J.2
-
76
-
-
79959738638
-
The performance evaluation of SMA Spring as actuator for gripping manipulation
-
Setiawan, M.A. The performance evaluation of SMA Spring as actuator for gripping manipulation. J. Teknik Elektro 2007, 7, 110-120.
-
(2007)
J. Teknik Elektro
, vol.7
, pp. 110-120
-
-
Setiawan, M.A.1
-
77
-
-
58149181346
-
Optimization design of multi-material micropump using finite element method
-
Zhu, M.; Kirby, P.; Wacklerle, M.; Herz, M.; Richter, M. Optimization design of multi-material micropump using finite element method. Sens. Actuators A 2009, 149, 130-135.
-
(2009)
Sens. Actuators A
, vol.149
, pp. 130-135
-
-
Zhu, M.1
Kirby, P.2
Wacklerle, M.3
Herz, M.4
Richter, M.5
-
78
-
-
79955919116
-
Simulation and verification of a piezoelectrically actuated diaphragm for check valve micropump design
-
in press
-
Kang, J.; Auner, G.W. Simulation and verification of a piezoelectrically actuated diaphragm for check valve micropump design. Sens. Actuators A 2011, in press.
-
(2011)
Sens. Actuators A
-
-
Kang, J.1
Auner, G.W.2
-
79
-
-
79955655748
-
Magnetic active-valve micropump actuated by a rotating magnetic assembly
-
Shen, M.; Dovat, L.; Gijs, M.A.M. Magnetic active-valve micropump actuated by a rotating magnetic assembly. Sens. Actuators B 2009, 154, 52-58.
-
(2009)
Sens. Actuators B
, vol.154
, pp. 52-58
-
-
Shen, M.1
Dovat, L.2
Gijs, M.A.M.3
-
80
-
-
69749094726
-
Design and simulation of a novel electrostatic peristaltic micromachined pump for drug delivery applications
-
Teymoori, M.M.; Abbaspour-Sani, E. Design and simulation of a novel electrostatic peristaltic micromachined pump for drug delivery applications. Sens. Actuators A 2005, 117, 222-229.
-
(2005)
Sens. Actuators A
, vol.117
, pp. 222-229
-
-
Teymoori, M.M.1
Abbaspour-Sani, E.2
-
81
-
-
0035888368
-
Fabrication and characterization of electroosmotic micropumps
-
Zeng, S.; Chen, C.H.; Mikkelsen, J.C.; Santiago, J.G. Fabrication and characterization of electroosmotic micropumps. Sens. Actuators B 2001, 79, 107-114.
-
(2001)
Sens. Actuators B
, vol.79
, pp. 107-114
-
-
Zeng, S.1
Chen, C.H.2
Mikkelsen, J.C.3
Santiago, J.G.4
-
82
-
-
27544458637
-
High Pressure Electroosmotic Pump Packed with Uniform Silica Nanosphers
-
In, Seoul, Korea, 5-9 June
-
Takemori, Y.; Horiike, S.; Nishimoto, T.; Nakanishi, H.; Yoshida, T. High Pressure Electroosmotic Pump Packed with Uniform Silica Nanosphers. In Proceedings of 13th International Conference on Solid State Sensors, Actuators and Microsystems, Seoul, Korea, 5-9 June 2005.
-
(2005)
Proceedings of 13th International Conference on Solid State Sensors, Actuators and Microsystems
-
-
Takemori, Y.1
Horiike, S.2
Nishimoto, T.3
Nakanishi, H.4
Yoshida, T.5
-
83
-
-
33846042197
-
Numerical study of electroosmotic (EO) flow in microfabricated EO pump with overlapped electrical double layer (EDL)
-
Hu, J.S.; Chao, C.Y.H. Numerical study of electroosmotic (EO) flow in microfabricated EO pump with overlapped electrical double layer (EDL). Int. J. Refrig. 2007, 30, 290-298.
-
(2007)
Int. J. Refrig.
, vol.30
, pp. 290-298
-
-
Hu, J.S.1
Chao, C.Y.H.2
-
84
-
-
33751421230
-
A water-activated pump for portable microfluidic applications
-
Good, B.T.; Bowman, C.N.; Davis, R.T. A water-activated pump for portable microfluidic applications. J. Colloid Interface Sci. 2007, 305, 239-249.
-
(2007)
J. Colloid Interface Sci.
, vol.305
, pp. 239-249
-
-
Good, B.T.1
Bowman, C.N.2
Davis, R.T.3
-
85
-
-
36148988796
-
Biodegradable microosmotic pump for long term and controlled release of basic fibroblast growth factor
-
Ryu, W.H.; Huang, Z.; Prinz, F.B. Goodman, S.B. Fasching, R. Biodegradable microosmotic pump for long term and controlled release of basic fibroblast growth factor. J. Control. Release 2007, 124, 98-105.
-
(2007)
J. Control. Release
, vol.124
, pp. 98-105
-
-
Ryu, W.H.1
Huang, Z.2
Prinz, F.B.3
Goodman, S.B.4
Fasching, R.5
-
86
-
-
34250200073
-
Massively parallel microfluidic pump
-
Yairi, M.; Richter, C. Massively parallel microfluidic pump. Sens. Actuators A 2007, 137, 350-356.
-
(2007)
Sens. Actuators A
, vol.137
, pp. 350-356
-
-
Yairi, M.1
Richter, C.2
-
87
-
-
41549093279
-
High pressure electroosmotic pump based on a packed bed planar microchip
-
Borowsky, J.; Lu, Q.; Collins, G.E. High pressure electroosmotic pump based on a packed bed planar microchip. Sens. Actuators B 2008, 131, 333-339.
-
(2008)
Sens. Actuators B
, vol.131
, pp. 333-339
-
-
Borowsky, J.1
Lu, Q.2
Collins, G.E.3
-
88
-
-
58149202232
-
Electroosmotic pumps for microflow analysis
-
Wang, X.; Wang, S.; Gendhar, B.; Cheng, C.; Byun, C.K.; Li, G.; Zhao, M.; Liu, S. Electroosmotic pumps for microflow analysis. Trends Anal. Chem. 2009, 28, 64-74.
-
(2009)
Trends Anal. Chem.
, vol.28
, pp. 64-74
-
-
Wang, X.1
Wang, S.2
Gendhar, B.3
Cheng, C.4
Byun, C.K.5
Li, G.6
Zhao, M.7
Liu, S.8
-
89
-
-
0036773089
-
A surface tension driven micropump for low voltage and low power operations
-
Yun, K.S.; Cho, I.J.; Bu, J.U.; Kim, C.J.; Yoon, E. A surface tension driven micropump for low voltage and low power operations. J. MEMS 2002, 11, 454-461.
-
(2002)
J. MEMS
, vol.11
, pp. 454-461
-
-
Yun, K.S.1
Cho, I.J.2
Bu, J.U.3
Kim, C.J.4
Yoon, E.5
-
90
-
-
4344584026
-
Electrowetting-based pico-liter liquid actuation in a glass-tube microinjector
-
Hoshino, K.; Triteyaprasert, S.; Matsumoto, K.; Shimoyama, I. Electrowetting-based pico-liter liquid actuation in a glass-tube microinjector. Sens. Actuators A 2004, 114, 473-477.
-
(2004)
Sens. Actuators A
, vol.114
, pp. 473-477
-
-
Hoshino, K.1
Triteyaprasert, S.2
Matsumoto, K.3
Shimoyama, I.4
-
91
-
-
0001110847
-
An investigation of electrowetting based microactuation
-
Colgate, E.D.; Matsumoto, H. An investigation of electrowetting based microactuation. J. Vac. Sci. Technol. A 1990, 4, 3625-3633.
-
(1990)
J. Vac. Sci. Technol. A
, vol.4
, pp. 3625-3633
-
-
Colgate, E.D.1
Matsumoto, H.2
-
92
-
-
77649238688
-
Driving characteristics of the electrowetting-on-dielectric device using atomic-layer-deposited aluminum oxide as the dielectric
-
Chang, J.; Choi, D.Y.; Han, S.; Pak, J.J. Driving characteristics of the electrowetting-on-dielectric device using atomic-layer-deposited aluminum oxide as the dielectric. Microfluid. Nanofluid. 2010, 8, 269-273.
-
(2010)
Microfluid. Nanofluid.
, vol.8
, pp. 269-273
-
-
Chang, J.1
Choi, D.Y.2
Han, S.3
Pak, J.J.4
-
93
-
-
0037144306
-
Areversible electrochemical nanosyringe pump and some considerations to realize low power consumption
-
Suzuki, H.; Yoneyama, R. Areversible electrochemical nanosyringe pump and some considerations to realize low power consumption. Sens. Actuators B 2002, 86, 242-250.
-
(2002)
Sens. Actuators B
, vol.86
, pp. 242-250
-
-
Suzuki, H.1
Yoneyama, R.2
-
94
-
-
0242489278
-
Integrated microfluidic system with electrochemically actuated on-chip pumps and valves
-
Suzuki, H.; Yoneyama, R. Integrated microfluidic system with electrochemically actuated on-chip pumps and valves. Sens. Actuators B 2003, 96, 38-45.
-
(2003)
Sens. Actuators B
, vol.96
, pp. 38-45
-
-
Suzuki, H.1
Yoneyama, R.2
-
95
-
-
15244362598
-
Development of an artificial synapse using an electrochemical micropump
-
Yoshimi, Y.; Shinoda, K.; Mishima, M.; Nakao, K.; Munekane, K. Development of an artificial synapse using an electrochemical micropump. J. Artif. Organs 2004, 7, 210-215.
-
(2004)
J. Artif. Organs
, vol.7
, pp. 210-215
-
-
Yoshimi, Y.1
Shinoda, K.2
Mishima, M.3
Nakao, K.4
Munekane, K.5
-
96
-
-
55349131660
-
Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump
-
Kim, J.H.; Laua, K.T.; Shepherd, R.; Wu, Y.; Wallace, G.; Diamond, D. Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump. Sens. Actuators A 2008, 148, 239-244.
-
(2008)
Sens. Actuators A
, vol.148
, pp. 239-244
-
-
Kim, J.H.1
Laua, K.T.2
Shepherd, R.3
Wu, Y.4
Wallace, G.5
Diamond, D.6
-
97
-
-
0036126479
-
An evaporation-based disposable micropump concept for continuous monitoring applications
-
Effenhauser, C.S.; Harttig, H.; Kramer, P. An evaporation-based disposable micropump concept for continuous monitoring applications. Biomed. Microdev. 2002, 4, 27-33.
-
(2002)
Biomed. Microdev.
, vol.4
, pp. 27-33
-
-
Effenhauser, C.S.1
Harttig, H.2
Kramer, P.3
-
98
-
-
0037340697
-
Transpirationbased micropump for delivering continuous ultra low flow rates
-
Namasivayam, V.; Larson, R.G.; Burke, D.T.; Burns, M.A. Transpirationbased micropump for delivering continuous ultra low flow rates. J. Micromech. Microeng. 2003, 13, 261-271.
-
(2003)
J. Micromech. Microeng.
, vol.13
, pp. 261-271
-
-
Namasivayam, V.1
Larson, R.G.2
Burke, D.T.3
Burns, M.A.4
-
99
-
-
30644476531
-
The use of a micropump based on capillary and evaporation effects in a microfluidic flow injection chemiluminescence system
-
Guan, Y.; Xua, Z.; Dai, J.; Fang, Z. The use of a micropump based on capillary and evaporation effects in a microfluidic flow injection chemiluminescence system. Talanta 2006, 68, 1384-1389.
-
(2006)
Talanta
, vol.68
, pp. 1384-1389
-
-
Guan, Y.1
Xua, Z.2
Dai, J.3
Fang, Z.4
-
100
-
-
44149085942
-
Evaporation based micro pump integrated into a scanning force microscope probe
-
Heuck, F.; Hug, T.; Akiyama, T.; Frederix, P.L.T.M.; Engel, A.; Meister, A.; Heinzelmann, H.; de Rooij, N.F.; Staufer, U. Evaporation based micro pump integrated into a scanning force microscope probe. Microelectr. Eng. 2008, 85, 1302-1305.
-
(2008)
Microelectr. Eng.
, vol.85
, pp. 1302-1305
-
-
Heuck, F.1
Hug, T.2
Akiyama, T.3
Frederix, P.L.T.M.4
Engel, A.5
Meister, A.6
Heinzelmann, H.7
de Rooij, N.F.8
Staufer, U.9
-
101
-
-
0035006727
-
A Thermal Bubble Actuated Micro Nozzle-diffuser Pump
-
In, Interlaken, Switzerland, 21-25 January
-
Tsai, J.H.; Lin, L.; A Thermal Bubble Actuated Micro Nozzle-diffuser Pump. In Proceedings of 14th IEEE International Conference Microelectromechanical Systems, Interlaken, Switzerland, 21-25 January 2001; pp. 409-412.
-
(2001)
Proceedings of 14th IEEE International Conference Microelectromechanical Systems
, pp. 409-412
-
-
Tsai, J.H.1
Lin, L.2
-
102
-
-
0036544174
-
Active microfluidic mixture and gas bubble filter driven by thermal bubble micropump
-
Tsai, J.H.; Lin, L. Active microfluidic mixture and gas bubble filter driven by thermal bubble micropump. Sens. Actuators A 2002, 97-98, 665-671.
-
(2002)
Sens. Actuators A
, vol.97-98
, pp. 665-671
-
-
Tsai, J.H.1
Lin, L.2
-
103
-
-
33845714919
-
A collapsing bubble-induced micropump: An experimental study
-
Lew, K.S.F.; Klaseboer, E.; Khoo, B.C. A collapsing bubble-induced micropump: An experimental study. Sens. Actuators A 2007, 133, 161-172.
-
(2007)
Sens. Actuators A
, vol.133
, pp. 161-172
-
-
Lew, K.S.F.1
Klaseboer, E.2
Khoo, B.C.3
-
104
-
-
33847144967
-
Fabrication and testing of bubble powered micropumps using embedded microheater
-
Jung, J.Y.; Kwak, H.Y. Fabrication and testing of bubble powered micropumps using embedded microheater. Microfluid. Nanofluid. 2007, 3, 161-169.
-
(2007)
Microfluid. Nanofluid.
, vol.3
, pp. 161-169
-
-
Jung, J.Y.1
Kwak, H.Y.2
-
105
-
-
35148814582
-
An Electrolysis-Bubble-Actuated micropump based on the roughness gradient design of hydrophobic surface
-
Cheng, C.M.; Liu, C.H. An Electrolysis-Bubble-Actuated micropump based on the roughness gradient design of hydrophobic surface. J. Microelectromech. Syst. 2007, 16, 1095-1105.
-
(2007)
J. Microelectromech. Syst.
, vol.16
, pp. 1095-1105
-
-
Cheng, C.M.1
Liu, C.H.2
-
106
-
-
78049475961
-
A bubble-activated micropump with high-frequency flow reversal
-
Chan, S.C.; Chen, C.R.; Liu, C.H. A bubble-activated micropump with high-frequency flow reversal. Sens. Actuators A 2010, 163, 501-509.
-
(2010)
Sens. Actuators A
, vol.163
, pp. 501-509
-
-
Chan, S.C.1
Chen, C.R.2
Liu, C.H.3
-
107
-
-
0033882554
-
Theoretical and experimental study of MHD (magnetohydrodynamic) micropump
-
Jang, J.; Lee, S.S. Theoretical and experimental study of MHD (magnetohydrodynamic) micropump. Sens. Actuators A 2000, 80, 84-89.
-
(2000)
Sens. Actuators A
, vol.80
, pp. 84-89
-
-
Jang, J.1
Lee, S.S.2
-
108
-
-
0037204021
-
Magneto Hydrodynamic (MHD) pump fabricated with ceramic tapes
-
Zhong, J.; Yi, M.; Bau, H.H. Magneto Hydrodynamic (MHD) pump fabricated with ceramic tapes. Sens. Actuators A 2002, 96, 59-66.
-
(2002)
Sens. Actuators A
, vol.96
, pp. 59-66
-
-
Zhong, J.1
Yi, M.2
Bau, H.H.3
-
109
-
-
0038587423
-
A circular ac magnetohydrodynamic micropump for chromatographic applications
-
Eijkel, J.C.T.; Dalton, C.; Hayden, C.J.; Burt, J.P.H.; Manz, A. A circular ac magnetohydrodynamic micropump for chromatographic applications. Sens. Actuators B 2003, 92, 215-221.
-
(2003)
Sens. Actuators B
, vol.92
, pp. 215-221
-
-
Eijkel, J.C.T.1
Dalton, C.2
Hayden, C.J.3
Burt, J.P.H.4
Manz, A.5
-
110
-
-
33847047812
-
Electroosmosis and thermal effects in Magnetohydrodynamic (MHD) micropumps using 3D MHD equations
-
Patel, V.; Kassegne, S.K. Electroosmosis and thermal effects in Magnetohydrodynamic (MHD) micropumps using 3D MHD equations. Sens. Actuators B 2007, 122, 42-52.
-
(2007)
Sens. Actuators B
, vol.122
, pp. 42-52
-
-
Patel, V.1
Kassegne, S.K.2
-
111
-
-
41949098834
-
Numerical Computation of Fluid Flow in a Magnetohydrodynamic Micropump
-
Duwairi, H.M.; Abdullah, M. Numerical Computation of Fluid Flow in a Magnetohydrodynamic Micropump. Turkish J. Eng. Env. Sci. 2008, 32, 1-5.
-
(2008)
Turkish J. Eng. Env. Sci.
, vol.32
, pp. 1-5
-
-
Duwairi, H.M.1
Abdullah, M.2
-
112
-
-
79951515959
-
Development of the MHD micropump with mixing function
-
Kang, H.; Choi, B. Development of the MHD micropump with mixing function. Sens. Actuators A 2010, 165, 439-445.
-
(2010)
Sens. Actuators A
, vol.165
, pp. 439-445
-
-
Kang, H.1
Choi, B.2
-
113
-
-
0000919566
-
Microtransport induced by ultrasonic lamb waves
-
Moroney, R.M.; White, R.M.; Howe, R.T. Microtransport induced by ultrasonic lamb waves. Appl. Phys. Lett. 1991, 59, 774-776.
-
(1991)
Appl. Phys. Lett.
, vol.59
, pp. 774-776
-
-
Moroney, R.M.1
White, R.M.2
Howe, R.T.3
-
114
-
-
0033345558
-
Design and optimization of an ultrasonic flexural plate wave micropump using numerical simulation
-
Nguyen, N.T.; White, R.M. Design and optimization of an ultrasonic flexural plate wave micropump using numerical simulation. Sens. Actuators A 1999, 77, 229-236.
-
(1999)
Sens. Actuators A
, vol.77
, pp. 229-236
-
-
Nguyen, N.T.1
White, R.M.2
-
115
-
-
0033900270
-
Integrated flow sensor for insitu measurement and control of acoustic streaming in flexural plate wave micropumps
-
Nguyen, N.T.; Meng, A.H.; Black, J.; White, R.M. Integrated flow sensor for insitu measurement and control of acoustic streaming in flexural plate wave micropumps. Sens. Actuators A 2000, 79, 115-121.
-
(2000)
Sens. Actuators A
, vol.79
, pp. 115-121
-
-
Nguyen, N.T.1
Meng, A.H.2
Black, J.3
White, R.M.4
-
116
-
-
0006402341
-
Focused flow micropump using ultrasonic flexural plate waves
-
Meng, A.H.; Nguyen, N.T.; White, R.M. Focused flow micropump using ultrasonic flexural plate waves. Biomed. Microdevices 2000, 2-3, 169-174.
-
(2000)
Biomed. Microdevices
, vol.2-3
, pp. 169-174
-
-
Meng, A.H.1
Nguyen, N.T.2
White, R.M.3
-
117
-
-
22844450447
-
Microfluidic circulatory flows induced by resonant vibration of diaphragms
-
Jang, L.S.; Chao, S.H.; Holl, M.R.; Meldrum, D.R. Microfluidic circulatory flows induced by resonant vibration of diaphragms. Sens. Actuators A 2005, 122, 141-148.
-
(2005)
Sens. Actuators A
, vol.122
, pp. 141-148
-
-
Jang, L.S.1
Chao, S.H.2
Holl, M.R.3
Meldrum, D.R.4
-
118
-
-
77951144661
-
Enhancement in Ultrasonic Micro-Transport Using Focused Inter-Digital Transducers in a Surface Acoustic Wave Device: Fluid-Structure Interaction Study
-
In, Christchurch, New Zealand, 25-28 October
-
Singh, R.; Bhethanabotla, V.R. Enhancement in Ultrasonic Micro-Transport Using Focused Inter-Digital Transducers in a Surface Acoustic Wave Device: Fluid-Structure Interaction Study. In Proceedings of IEEE Sensors, Christchurch, New Zealand, 25-28 October 2009.
-
(2009)
Proceedings of IEEE Sensors
-
-
Singh, R.1
Bhethanabotla, V.R.2
-
119
-
-
0025598707
-
An Electrohydrodynamic Micropump
-
In, Napa Valley, CA, USA, 11-14 February
-
Richter, A.; Sandmaier, H. An Electrohydrodynamic Micropump. In Proceedings of IEEE Microelectromechanical Systems, Napa Valley, CA, USA, 11-14 February 1990; pp. 99-104.
-
(1990)
Proceedings of IEEE Microelectromechanical Systems
, pp. 99-104
-
-
Richter, A.1
Sandmaier, H.2
-
120
-
-
0027084127
-
Pumping of Water Solutions in Microfabricated Electrohydrodynamic Systems
-
In, Travemunde, Germany, 4-7 February
-
Fuhr, G.; Hagedorn, R.; Muller, T.; Benecke, W.; Wagner, B. Pumping of Water Solutions in Microfabricated Electrohydrodynamic Systems. In Proceedings of IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots MEMS, Travemunde, Germany, 4-7 February 1992; pp. 25-30.
-
(1992)
Proceedings of IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots MEMS
, pp. 25-30
-
-
Fuhr, G.1
Hagedorn, R.2
Muller, T.3
Benecke, W.4
Wagner, B.5
-
121
-
-
0035278846
-
An Electrohydrodynamic polarization micropump for electronic cooling
-
Darabi, J.; Ohadi, M. M.; DeVoe, D. An Electrohydrodynamic polarization micropump for electronic cooling. J. Microelectromech. Syst. 2001, 10, 98-106.
-
(2001)
J. Microelectromech. Syst.
, vol.10
, pp. 98-106
-
-
Darabi, J.1
Ohadi, M.M.2
DeVoe, D.3
-
122
-
-
0036906211
-
Design, fabrication and testing of an electrohydrodynamic ion drag micropump
-
Darabi, J.; Rada, M.; Ohadi, M.; Lawler, J. Design, fabrication and testing of an electrohydrodynamic ion drag micropump. J. Microelectromech. Syst. 2002, 11, 684-690.
-
(2002)
J. Microelectromech. Syst.
, vol.11
, pp. 684-690
-
-
Darabi, J.1
Rada, M.2
Ohadi, M.3
Lawler, J.4
-
123
-
-
0442280356
-
The micro ion drag pump using indium-tin-oxide (ITO) electrodes to resist aging
-
Yang, L.J.; Wang, J.M.; Huang, Y.L. The micro ion drag pump using indium-tin-oxide (ITO) electrodes to resist aging. Sens. Actuators A 2004, 111, 118-122.
-
(2004)
Sens. Actuators A
, vol.111
, pp. 118-122
-
-
Yang, L.J.1
Wang, J.M.2
Huang, Y.L.3
-
124
-
-
22844435540
-
3D numerical micro-cooling analysis for an electrohydrodynamic micro-pump
-
Lin, C.W.; Jang, J.Y. 3D numerical micro-cooling analysis for an electrohydrodynamic micro-pump. Sens. Actuators A 2005, 122, 167-176.
-
(2005)
Sens. Actuators A
, vol.122
, pp. 167-176
-
-
Lin, C.W.1
Jang, J.Y.2
-
125
-
-
32844454930
-
CFD modeling of an ion-drag micropump
-
Darabi, J.; Rhodes, C. CFD modeling of an ion-drag micropump. Sens. Actuators A 2006, 127, 94-103.
-
(2006)
Sens. Actuators A
, vol.127
, pp. 94-103
-
-
Darabi, J.1
Rhodes, C.2
-
126
-
-
33847371990
-
Induction electrohydrodynamics micropump for high heat flux cooling
-
Singhal, V.; Garimella, S.V. Induction electrohydrodynamics micropump for high heat flux cooling. Sens. Actuators A 2007, 134, 650-659.
-
(2007)
Sens. Actuators A
, vol.134
, pp. 650-659
-
-
Singhal, V.1
Garimella, S.V.2
-
127
-
-
65949113622
-
EHD Micropump using Pyrolyzed Polymer 3-D Carbon Mesh Electrodes
-
In, Sorrento, Italy, 25-29 January
-
Wakui, D.; Imai, N.; Nagaura, Y.; Sato, H.; Sekiguchi, T.; Konishi, S.; Shoji, S.; Homma, T.; EHD Micropump using Pyrolyzed Polymer 3-D Carbon Mesh Electrodes. In Proceedings of 22nd IEEE International Conference on Micro Electro Mechanical Systems, Sorrento, Italy, 25-29 January 2009; pp. 499-502.
-
(2009)
Proceedings of 22nd IEEE International Conference on Micro Electro Mechanical Systems
, pp. 499-502
-
-
Wakui, D.1
Imai, N.2
Nagaura, Y.3
Sato, H.4
Sekiguchi, T.5
Konishi, S.6
Shoji, S.7
Homma, T.8
-
128
-
-
77957661674
-
A two-liquid electroosmotic pump using low applied voltage and power
-
Litster, S.; Suss, M.E. Santiago, J.G. A two-liquid electroosmotic pump using low applied voltage and power. Sens. Actuators A 2010, 163, 311-314.
-
(2010)
Sens. Actuators A
, vol.163
, pp. 311-314
-
-
Litster, S.1
Suss, M.E.2
Santiago, J.G.3
-
129
-
-
71649094859
-
An osmotic micro-pump integrated on a microfluidic chip for perfusion cell culture
-
Xu, Z.; Yang, C.; Liua, C.; Zhou, Z.; Fang, J.; Wang, J.; An osmotic micro-pump integrated on a microfluidic chip for perfusion cell culture. Talanta 2010, 80, 1088-1093.
-
(2010)
Talanta
, vol.80
, pp. 1088-1093
-
-
Xu, Z.1
Yang, C.2
Liua, C.3
Zhou, Z.4
Fang, J.5
Wang, J.6
-
130
-
-
70349617461
-
A study on the MHD (magnetohydrodynamic) micropump with side-walled electrodes
-
Lim, S.; Choi, B. A study on the MHD (magnetohydrodynamic) micropump with side-walled electrodes. J. Mech. Sci. Technol. 2009, 23, 739-749.
-
(2009)
J. Mech. Sci. Technol.
, vol.23
, pp. 739-749
-
-
Lim, S.1
Choi, B.2
-
131
-
-
0031354318
-
Microfabricated lamb wave device based on PZT sol-gel thin film for mechanical transport of solid particles and liquids
-
Luginbuhl, P. Microfabricated lamb wave device based on PZT sol-gel thin film for mechanical transport of solid particles and liquids. J. Microelectromech. Syst. 1997, 6, 337-345.
-
(1997)
J. Microelectromech. Syst.
, vol.6
, pp. 337-345
-
-
Luginbuhl, P.1
-
132
-
-
0026205082
-
A silicon-based three dimensional neural interface: Manufacturing processes for an intracortical electrode array
-
Campbell, P.K.; Jones, K.E.; Huber, R.J.; Horch, K.W.; Normann, R.A. A silicon-based three dimensional neural interface: Manufacturing processes for an intracortical electrode array. IEEE Trans. Biomed. Eng. 1991, 38, 758-768.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 758-768
-
-
Campbell, P.K.1
Jones, K.E.2
Huber, R.J.3
Horch, K.W.4
Normann, R.A.5
-
133
-
-
77649235080
-
Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications
-
Bodhale, D.W.; Nisar, A.; Afzulpurkar, N. Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications. Microfluid. Nanofluid. 2010, 8, 373-392.
-
(2010)
Microfluid. Nanofluid.
, vol.8
, pp. 373-392
-
-
Bodhale, D.W.1
Nisar, A.2
Afzulpurkar, N.3
-
134
-
-
0022863439
-
An implantable multielectrode array with on-chip signal processing
-
Najafi, K.; Wise, K. An implantable multielectrode array with on-chip signal processing. IEEE J. Solid-State Circ 1986, 21, 1035-1044.
-
(1986)
IEEE J. Solid-State Circ
, vol.21
, pp. 1035-1044
-
-
Najafi, K.1
Wise, K.2
-
135
-
-
0031214943
-
A multichannel neural probe for selective chemical delivery at the cellular level
-
Chen, J.; Wise, K.; Hetke, J.; Bledsoe, S. A multichannel neural probe for selective chemical delivery at the cellular level. IEEE Trans. Biomed. Eng. 1997, 44, 760-769.
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
, pp. 760-769
-
-
Chen, J.1
Wise, K.2
Hetke, J.3
Bledsoe, S.4
-
136
-
-
0034055301
-
A high-yield microassembly structure for three dimensional microelectrode arrays
-
Bai, Q.; Wise, K.; Anderson, D. A high-yield microassembly structure for three dimensional microelectrode arrays. IEEE Trans. Biomed. Eng. 2000, 47, 281-289.
-
(2000)
IEEE Trans. Biomed. Eng.
, vol.47
, pp. 281-289
-
-
Bai, Q.1
Wise, K.2
Anderson, D.3
-
137
-
-
0040451922
-
Hypodermic injection. The world book encyclopedia
-
The World Book Encyclopedia
-
The World Book Encyclopedia. Hypodermic injection. The world book encyclopedia. World Book Chic 1999, 9, 480-481.
-
(1999)
World Book Chic
, vol.9
, pp. 480-481
-
-
-
140
-
-
84945532041
-
-
Available online:, (accessed on 27 April 2011)
-
Zosano Pharma. Available online: http://www.zosanopharma.com (accessed on 27 April 2011).
-
Zosano Pharma
-
-
-
141
-
-
70350231749
-
Demonstrated solid-state stability of parathyroid hormone PTH(1-34) coated on a novel transdermal microprojection delivery system
-
Ameri, M.; Daddona, P.; Maa, Y. Demonstrated solid-state stability of parathyroid hormone PTH(1-34) coated on a novel transdermal microprojection delivery system. Pharm. Res. 2009, 26, 2454-2463.
-
(2009)
Pharm. Res.
, vol.26
, pp. 2454-2463
-
-
Ameri, M.1
Daddona, P.2
Maa, Y.3
-
142
-
-
77949270202
-
Parathyroid hormone PTH(1-34) formulation that enables uniform coating on a novel transdermal microprojection delivery system
-
Ameri, M.; Daddona, P.; Maa, Y. Parathyroid hormone PTH(1-34) formulation that enables uniform coating on a novel transdermal microprojection delivery system. Pharm. Res. 2009, 27, 303-313.
-
(2009)
Pharm. Res.
, vol.27
, pp. 303-313
-
-
Ameri, M.1
Daddona, P.2
Maa, Y.3
-
143
-
-
0027845301
-
An ion milling pattern transfer technique for fabrication of three-dimensional micromechanical structures
-
Dizon, R.; Han, H.; Russell, A.; Reed, M. An ion milling pattern transfer technique for fabrication of three-dimensional micromechanical structures. J. Microelectromech. Syst. 1993, 2, 151-159.
-
(1993)
J. Microelectromech. Syst.
, vol.2
, pp. 151-159
-
-
Dizon, R.1
Han, H.2
Russell, A.3
Reed, M.4
-
144
-
-
0031852494
-
Microfabricated microneedles: A novel approach to transdermal drug delivery
-
Henry, S.; McAllister, D.; Allen, M.; Prausnitz, M. Microfabricated microneedles: A novel approach to transdermal drug delivery. J. Pharm. Sci. 1998, 87, 922-925.
-
(1998)
J. Pharm. Sci.
, vol.87
, pp. 922-925
-
-
Henry, S.1
McAllister, D.2
Allen, M.3
Prausnitz, M.4
-
145
-
-
79959770638
-
DNA injection into cell conglomerates by micromachined hollow microcapillary arrays
-
In, Sendai, Japan, 7-10 June
-
Chun, K.; Hashiguchi, G.; Toshioyoshi, H.; Pioufle, B.; Ishikawa, J.; Murakami, Y.; Tamiya, E.; Kikuchi, Y.; Fujita, H. DNA injection into cell conglomerates by micromachined hollow microcapillary arrays. In Proceedings of Digital Transducers, 10th International Conference Solid-State Sensors and Actuators, Sendai, Japan, 7-10 June 1999; pp. 41-47.
-
(1999)
Proceedings of Digital Transducers, 10th International Conference Solid-State Sensors and Actuators
, pp. 41-47
-
-
Chun, K.1
Hashiguchi, G.2
Toshioyoshi, H.3
Pioufle, B.4
Ishikawa, J.5
Murakami, Y.6
Tamiya, E.7
Kikuchi, Y.8
Fujita, H.9
-
146
-
-
0036544241
-
Fabrication of a microneedle for a trace blood test
-
Oka, K.; Aoyagi, S.; Arai, Y.; Isono, Y.; Hashiguchi, G.; Fujita, H. Fabrication of a microneedle for a trace blood test. Sens. Actuators A 2002, 97-98, 478-485.
-
(2002)
Sens. Actuators A
, vol.97-98
, pp. 478-485
-
-
Oka, K.1
Aoyagi, S.2
Arai, Y.3
Isono, Y.4
Hashiguchi, G.5
Fujita, H.6
-
147
-
-
0038029170
-
Hollow metallic micromachined needle arrays
-
Brazzle, J.; Papautsky, I.; Frazier, B. Hollow metallic micromachined needle arrays. J. Biomed. Devices 2000, 2, 197-205.
-
(2000)
J. Biomed. Devices
, vol.2
, pp. 197-205
-
-
Brazzle, J.1
Papautsky, I.2
Frazier, B.3
-
148
-
-
0038547999
-
Surface micromachined metallic microneedles
-
Chandrasekaran, S.; Brazzle, J.D.; Frazier, A.B. Surface micromachined metallic microneedles. J. Microelectromech. Syst. 2003, 12, 289-295.
-
(2003)
J. Microelectromech. Syst.
, vol.12
, pp. 289-295
-
-
Chandrasekaran, S.1
Brazzle, J.D.2
Frazier, A.B.3
-
149
-
-
0037699910
-
Characterization of surface micromachined metallic microneedles
-
Chandrasekaran, S.; Frazier, A.B. Characterization of surface micromachined metallic microneedles. J. Microelectromech. Syst. 2003, 12, 281-288.
-
(2003)
J. Microelectromech. Syst.
, vol.12
, pp. 281-288
-
-
Chandrasekaran, S.1
Frazier, A.B.2
-
150
-
-
2442578286
-
Design, Fabrication and Testing of a MEMS Syringe
-
In, Hilton Head Island, SC, USA, 2-6 June
-
Stoeber, B.; Liepmann, D. Design, Fabrication and Testing of a MEMS Syringe. In Proceedings of Solid-State Sensors, Actuator and Microsystems Workshop, Hilton Head Island, SC, USA, 2-6 June 2002; pp. 77-80.
-
(2002)
Proceedings of Solid-State Sensors, Actuator and Microsystems Workshop
, pp. 77-80
-
-
Stoeber, B.1
Liepmann, D.2
-
151
-
-
0028806620
-
Genetic transformation of nematodes using arrays of micromechanical piercing structures
-
Hashmi, S.; Ling, P.; Hashmi, G.; Reed, M.; Gaugler, R.; Trimmer, W. Genetic transformation of nematodes using arrays of micromechanical piercing structures. Biotechniques 1995, 19, 766-770.
-
(1995)
Biotechniques
, vol.19
, pp. 766-770
-
-
Hashmi, S.1
Ling, P.2
Hashmi, G.3
Reed, M.4
Gaugler, R.5
Trimmer, W.6
-
152
-
-
78649616098
-
Medical prototyping using two photon polymerization
-
Narayan, J.R.; Doraiswamy, A.; Chrisey, D.B.; Chichkov, B.N. Medical prototyping using two photon polymerization. Materialstoday 2010, 12, 43-48.
-
(2010)
Materialstoday
, vol.12
, pp. 43-48
-
-
Narayan, J.R.1
Doraiswamy, A.2
Chrisey, D.B.3
Chichkov, B.N.4
-
153
-
-
48749105332
-
Microneedle-based drug delivery: Studies on delivery parameters and biocompatibility
-
Wu, Y.; Qiu, Y.; Zhang, S.; Qin, G.; Gao, Y. Microneedle-based drug delivery: Studies on delivery parameters and biocompatibility. Biomed. Microdevices 2008, 10, 601-610.
-
(2008)
Biomed. Microdevices
, vol.10
, pp. 601-610
-
-
Wu, Y.1
Qiu, Y.2
Zhang, S.3
Qin, G.4
Gao, Y.5
-
154
-
-
57849157314
-
Microneedle mediated delivery of nanoparticles into human skin
-
Coulman, S.A.; Ansteyb, A.; Gateleyb, C.; Morrisseyc, A.; McLoughlind, P.; Allendera, C.; Birchalla, J.C. Microneedle mediated delivery of nanoparticles into human skin. Int. J. Pharm. 2009, 366, 190-200.
-
(2009)
Int. J. Pharm.
, vol.366
, pp. 190-200
-
-
Coulman, S.A.1
Ansteyb, A.2
Gateleyb, C.3
Morrisseyc, A.4
McLoughlind, P.5
Allendera, C.6
Birchalla, J.C.7
-
155
-
-
59949083746
-
Clinical administration of microneedles: Skin puncture, pain and sensation
-
Haq, M.I.; Smith, E.; John, D.N.; Kalavala, M.; Edwards, C.; Anstey, A.; Morrissey, A.; Birchall, J.C. Clinical administration of microneedles: skin puncture, pain and sensation. Biomed. Microdevices 2009, 11, 35-47.
-
(2009)
Biomed. Microdevices
, vol.11
, pp. 35-47
-
-
Haq, M.I.1
Smith, E.2
John, D.N.3
Kalavala, M.4
Edwards, C.5
Anstey, A.6
Morrissey, A.7
Birchall, J.C.8
-
156
-
-
48149083798
-
Influence of the delivery systems using a microneedle array on the permeation of a hydrophilic molecule, calcein
-
Oh, J.H.; Park, H.H.; Do.; K.Y.; Han, M.; Hyun, D.H.; Kim, C.G.; Kim, C.H.; Lee, S.S.; Hwang, S.J.; Shin, S.C.; Cho, C.W. Influence of the delivery systems using a microneedle array on the permeation of a hydrophilic molecule, calcein, Eur. J. Pharm. Biopharm. 2008, 69, 1040-1045.
-
(2008)
Eur. J. Pharm. Biopharm.
, vol.69
, pp. 1040-1045
-
-
Oh, J.H.1
Park, H.H.2
Do, K.Y.3
Han, M.4
Hyun, D.H.5
Kim, C.G.6
Kim, C.H.7
Lee, S.S.8
Hwang, S.J.9
Shin, S.C.10
Cho, C.W.11
-
157
-
-
84952647272
-
Fluid Injection Through Out-of-plane Microneedles
-
In, Berkeley, CA, USA, 12-14 October
-
Stoeber, B.; Liepmann, D. Fluid Injection Through Out-of-plane Microneedles. In Proceedings of 1st Annual International Conference on Microtechnologies in Medicine and Biology, Berkeley, CA, USA, 12-14 October 2000.
-
(2000)
Proceedings of 1st Annual International Conference on Microtechnologies in Medicine and Biology
-
-
Stoeber, B.1
Liepmann, D.2
-
158
-
-
0037871729
-
Side-opened out-of-plane microneedles for microfluidics transdermal liquid transfer
-
Griss, P.; Stemme, G. Side-opened out-of-plane microneedles for microfluidics transdermal liquid transfer. J Microelectromech. Syst. 2003, 12, 296-301.
-
(2003)
J Microelectromech. Syst.
, vol.12
, pp. 296-301
-
-
Griss, P.1
Stemme, G.2
-
159
-
-
4344679112
-
In-plane single-crystal-silicon microneedles for minimally invasive microfluidic systems
-
Paik, S.J.; Byuna, S.; Lima, J.M.; Park, Y.; Leea, A.; Chungb, S.; Changa, J.; Chuna, K.; Cho, D. In-plane single-crystal-silicon microneedles for minimally invasive microfluidic systems. Sens. Actuators A 2004, 114, 276-284.
-
(2004)
Sens. Actuators A
, vol.114
, pp. 276-284
-
-
Paik, S.J.1
Byuna, S.2
Lima, J.M.3
Park, Y.4
Leea, A.5
Chungb, S.6
Changa, J.7
Chuna, K.8
Cho, D.9
-
160
-
-
24944508964
-
Silicon microneedle electrode array with temperature monitoring for electroporation
-
Wilke, N.; Hibert, C.; O'Brien, J.; Morrissey, A. Silicon microneedle electrode array with temperature monitoring for electroporation. Sens. Actuators A 2005, 123-124, 319-325.
-
(2005)
Sens. Actuators A
, vol.123-124
, pp. 319-325
-
-
Wilke, N.1
Hibert, C.2
O'Brien, J.3
Morrissey, A.4
-
161
-
-
34250724391
-
Insertion Force Estimation of Various Microneedle Array-type Structures Fabricated by a Microstereolithography Apparatus
-
In, Busan, Korea, 18-21 October
-
Choi, J.W.; Park, I.B.; Ha, Y.M.; Jung, M.G.; Lee, S.D.; Lee, S.H. Insertion Force Estimation of Various Microneedle Array-type Structures Fabricated by a Microstereolithography Apparatus. In Proceedings of International Joint Conference SICE-ICASE, Busan, Korea, 18-21 October 2006; pp. 3678-3681.
-
(2006)
Proceedings of International Joint Conference SICE-ICASE
, pp. 3678-3681
-
-
Choi, J.W.1
Park, I.B.2
Ha, Y.M.3
Jung, M.G.4
Lee, S.D.5
Lee, S.H.6
-
162
-
-
50049125622
-
Fabrication and mechanical characterization of microneedle array for cell surgery
-
In, Transducers, Lyon, France, 10-14 June
-
Shibata, T.; Nakanishi, A.; Sakai, T.; Kato, N.; Kawashima, T.; Mineta, T.; Makino, E. Fabrication and mechanical characterization of microneedle array for cell surgery. In Proceedings of Solid-State Sensors, Actuators and Microsystems Conference, Transducers, Lyon, France, 10-14 June 2007; pp. 719-722.
-
(2007)
Proceedings of Solid-State Sensors, Actuators and Microsystems Conference
, pp. 719-722
-
-
Shibata, T.1
Nakanishi, A.2
Sakai, T.3
Kato, N.4
Kawashima, T.5
Mineta, T.6
Makino, E.7
-
164
-
-
2942592481
-
Bioabsorbable implants, review of clinical experience in orthopedic surgery
-
Ambrose, C.G.; Clanto, T.O. Bioabsorbable implants, review of clinical experience in orthopedic surgery. Ann. Biomed. Eng. 2004, 32, 171-177.
-
(2004)
Ann. Biomed. Eng.
, vol.32
, pp. 171-177
-
-
Ambrose, C.G.1
Clanto, T.O.2
-
165
-
-
18144410179
-
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
-
Park, J.H.; Allen, M.G.; Prausnitz, M.R. Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery. J. Control. Release 2005, 104, 51-66.
-
(2005)
J. Control. Release
, vol.104
, pp. 51-66
-
-
Park, J.H.1
Allen, M.G.2
Prausnitz, M.R.3
-
166
-
-
40949162429
-
Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis
-
Aoyagi, S.; Izumi, H.; Fukuda, M. Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis. Sens. Actuators A 2008, 143, 20-28.
-
(2008)
Sens. Actuators A
, vol.143
, pp. 20-28
-
-
Aoyagi, S.1
Izumi, H.2
Fukuda, M.3
-
167
-
-
58549106105
-
Intrascleral drug delivery to the eye using hollow microneedles
-
Jiang, J.; Moore, J.S.; Edelhauser, H.F.; Prausnitz, M.R. Intrascleral drug delivery to the eye using hollow microneedles. Pharm. Res. 2009, 26, 395-403.
-
(2009)
Pharm. Res.
, vol.26
, pp. 395-403
-
-
Jiang, J.1
Moore, J.S.2
Edelhauser, H.F.3
Prausnitz, M.R.4
-
168
-
-
34147180022
-
Bulk micromachined Titanium microneedles
-
Parker, E.R.; Rao, M.P.; Turner, K.L.; Meinhart, C.D.; MacDonald, N.C.; Bulk micromachined Titanium microneedles. J. Microelectromech. Syst. 2007, 16, 2, 289-295.
-
(2007)
J. Microelectromech. Syst.
, vol.16
, Issue.2
, pp. 289-295
-
-
Parker, E.R.1
Rao, M.P.2
Turner, K.L.3
Meinhart, C.D.4
McDonald, N.C.5
-
169
-
-
34047171295
-
Implantation mechanics of tungsten microneedles into peripheral nerve truks
-
Yoshida, K.; Lewinsky, I.; Nielsen, M.; Hylleberg, M. Implantation mechanics of tungsten microneedles into peripheral nerve truks. Med. Bio. Eng. Comput. 2007, 45, 413-420.
-
(2007)
Med. Bio. Eng. Comput.
, vol.45
, pp. 413-420
-
-
Yoshida, K.1
Lewinsky, I.2
Nielsen, M.3
Hylleberg, M.4
-
170
-
-
79959750231
-
Optimization of Fabrication Process for MEMS based Microneedles Using ICP Etching Technology
-
In, Changsha, China, 14-15 December
-
Ashraf, M.W.; Tayyaba, S.; Afzulpurkar, N.; Nisar, A. Punyasai, C.; Saejok, K.; Supadech, J.; Atthi, N.; Hruanun, C.; Poyai, A. Optimization of Fabrication Process for MEMS based Microneedles Using ICP Etching Technology. In Proceedings of 6th international Conference on MEMS, Nano and Smart System (ICMENS), Changsha, China, 14-15 December 2010; pp. 356-359.
-
(2010)
Proceedings of 6th international Conference on MEMS, Nano and Smart System (ICMENS)
, pp. 356-359
-
-
Ashraf, M.W.1
Tayyaba, S.2
Afzulpurkar, N.3
Nisar, A.4
Punyasai, C.5
Saejok, K.6
Supadech, J.7
Atthi, N.8
Hruanun, C.9
Poyai, A.10
-
171
-
-
32544456007
-
Development of Blood Extraction System for Health Monitoring System
-
Tsuchiya, K.; Nakanishi, N.; Uetsuji, Y.; Nakamachi, E. Development of Blood Extraction System for Health Monitoring System. Biomed. Devices 2005, 7, 347-353.
-
(2005)
Biomed. Devices
, vol.7
, pp. 347-353
-
-
Tsuchiya, K.1
Nakanishi, N.2
Uetsuji, Y.3
Nakamachi, E.4
-
172
-
-
67349252458
-
Microneedles arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice
-
Ding, Z.; Verbaan, F.J.; Bivas-Benita, M.; Bungener, L.; Huckriede, A.; van den Berg, D.G.; Kersten, G.; Bouwstra, J.A. Microneedles arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice. J. Control. Release 2009, 136, 71-78.
-
(2009)
J. Control. Release
, vol.136
, pp. 71-78
-
-
Ding, Z.1
Verbaan, F.J.2
Bivas-Benita, M.3
Bungener, L.4
Huckriede, A.5
van den Berg, D.G.6
Kersten, G.7
Bouwstra, J.A.8
-
173
-
-
77149175967
-
Sonophoretic enhanced microneedles array (SEMA)-improving the efficiency of transdermal drug delivery
-
Chen, B.; Wei, J.; Iliescu, C. Sonophoretic enhanced microneedles array (SEMA)-improving the efficiency of transdermal drug delivery. Sens. Actuators B 2010, 145, 54-60.
-
(2010)
Sens. Actuators B
, vol.145
, pp. 54-60
-
-
Chen, B.1
Wei, J.2
Iliescu, C.3
-
174
-
-
78349312540
-
Penetration and distribution of PLGA nanoparticles in the human skin treated with microneedles
-
Zhang, W.; Gao, J.; Zhu, Q.; Zhang, M.; Ding, X.; Wang, X.; Hou, X.; Fan, W.; Ding, B.; Wu, X.; Wang, X.; Gao, S. Penetration and distribution of PLGA nanoparticles in the human skin treated with microneedles. Int. J. Pharm. 2010, 402, 205-212.
-
(2010)
Int. J. Pharm.
, vol.402
, pp. 205-212
-
-
Zhang, W.1
Gao, J.2
Zhu, Q.3
Zhang, M.4
Ding, X.5
Wang, X.6
Hou, X.7
Fan, W.8
Ding, B.9
Wu, X.10
Wang, X.11
Gao, S.12
-
175
-
-
67650417889
-
Design and fabrication of MEMS based microneedle arrays for medical applications
-
Zhang, P.; Dalton, C.; Jullien, G.A. Design and fabrication of MEMS based microneedle arrays for medical applications. Microsyst. Technol. 2009, 15, 1073-1082.
-
(2009)
Microsyst. Technol.
, vol.15
, pp. 1073-1082
-
-
Zhang, P.1
Dalton, C.2
Jullien, G.A.3
-
176
-
-
63049113180
-
A microfabricated electrode with Hollow microneedles for ECG measurement
-
Yu, L.M.; Tay, F.E.H.; Guo, D.G.; Xu, L.; Yap, K.L. A microfabricated electrode with Hollow microneedles for ECG measurement. Sens. Actuators A 2009, 151, 17-22.
-
(2009)
Sens. Actuators A
, vol.151
, pp. 17-22
-
-
Yu, L.M.1
Tay, F.E.H.2
Guo, D.G.3
Xu, L.4
Yap, K.L.5
-
177
-
-
44249091951
-
Silicon microneedle array with biodegradable tip for transdermal drug delivery
-
Chen, B.; Wei, J.; Tay, F.E.H. Silicon microneedle array with biodegradable tip for transdermal drug delivery. Microsyst. Technol. 2008, 14, 1015-1019.
-
(2008)
Microsyst. Technol.
, vol.14
, pp. 1015-1019
-
-
Chen, B.1
Wei, J.2
Tay, F.E.H.3
-
178
-
-
40349099997
-
Membrane-seald hollow microneedles and related administration schemes for transdermal drug delivery
-
Roxhed, N.; Griss, P.; Stemme, G. Membrane-seald hollow microneedles and related administration schemes for transdermal drug delivery. Biomed. Microdevices 2008, 10, 271-279.
-
(2008)
Biomed. Microdevices
, vol.10
, pp. 271-279
-
-
Roxhed, N.1
Griss, P.2
Stemme, G.3
-
179
-
-
51349149670
-
A novel mask-less method of fabricating high aspect ratio microneedles for blood sampling
-
In, Lake Buena Vista, FL, USA, 27-30 May
-
Bhandari, R.; Negi, S.; Solzbacher, F. A novel mask-less method of fabricating high aspect ratio microneedles for blood sampling. In Proceedings of IEEE 58th Electronic Components and Technology Conference, Lake Buena Vista, FL, USA, 27-30 May 2008; pp. 1306-1309.
-
(2008)
Proceedings of IEEE 58th Electronic Components and Technology Conference
, pp. 1306-1309
-
-
Bhandari, R.1
Negi, S.2
Solzbacher, F.3
-
180
-
-
47349128121
-
Microneedle-mediated Intradermal delivery of 5-aminolevulinic acid: Potential for enhanced topical photodynamic therapy
-
Donnelly, R.F.; Morrow, D.I.J.; McCarron, P.A.; Woolfson, A.D.; Morrissey, A.; Juzenas, P.; Juzeniene, A.; Lani, V.; McCarthy, H.O.; Moan, J. Microneedle-mediated Intradermal delivery of 5-aminolevulinic acid: Potential for enhanced topical photodynamic therapy. J. Control. Release 2008, 129, 154-162.
-
(2008)
J. Control. Release
, vol.129
, pp. 154-162
-
-
Donnelly, R.F.1
Morrow, D.I.J.2
McCarron, P.A.3
Woolfson, A.D.4
Morrissey, A.5
Juzenas, P.6
Juzeniene, A.7
Lani, V.8
McCarthy, H.O.9
Moan, J.10
-
181
-
-
40049112272
-
Dissolving microneedles for transdermal drug delivery
-
Lee, J.W.; Park, J.H.; Prausnitz, M.R. Dissolving microneedles for transdermal drug delivery. Biomaterials 2008, 29, 2113-2124.
-
(2008)
Biomaterials
, vol.29
, pp. 2113-2124
-
-
Lee, J.W.1
Park, J.H.2
Prausnitz, M.R.3
-
182
-
-
77957280275
-
A microneedle roller for transdermal drug delivery
-
Park, J.H.; Choi, S.; Seo, S.; Choy, Y.B.; Prausnitz, M.R. A microneedle roller for transdermal drug delivery. Eur. J. Pharm. Biopharm. 2010, 76, 282-289.
-
(2010)
Eur. J. Pharm. Biopharm.
, vol.76
, pp. 282-289
-
-
Park, J.H.1
Choi, S.2
Seo, S.3
Choy, Y.B.4
Prausnitz, M.R.5
-
183
-
-
77957019129
-
Effects of microneedle length, densty, insertion time and multiple applications on human skin barrier function: Assessments by transdermal water loss
-
Gomaa, Y.A.; Morrow, D.I.J.; Garland, M.J.; Donnelly, R.F.; El-Khordagui, L.K. Effects of microneedle length, densty, insertion time and multiple applications on human skin barrier function: Assessments by transdermal water loss. Toxicol. in Vitro 2010, 24, 1971-1978.
-
(2010)
Toxicol. in Vitro
, vol.24
, pp. 1971-1978
-
-
Gomaa, Y.A.1
Morrow, D.I.J.2
Garland, M.J.3
Donnelly, R.F.4
El-Khordagui, L.K.5
-
184
-
-
78649636402
-
Microneedle-mediated Intradermal nanopartile delivery: Potential for ehnaced local administration of hydrophobic pre-formed photosensitisers
-
Donnelly, R.F.; Morrow, D.I.J.; Fay, F.; Scott, C.J.; Abdelghany, S.; Sing, R.R.T.; Garland, M.J.; Woolfson, A.D. Microneedle-mediated Intradermal nanopartile delivery: Potential for ehnaced local administration of hydrophobic pre-formed photosensitisers. Photodiagn. Photodynam. 2010, 7, 222-231.
-
(2010)
Photodiagn. Photodynam.
, vol.7
, pp. 222-231
-
-
Donnelly, R.F.1
Morrow, D.I.J.2
Fay, F.3
Scott, C.J.4
Abdelghany, S.5
Sing, R.R.T.6
Garland, M.J.7
Woolfson, A.D.8
-
185
-
-
67349210360
-
Poly vinyl alcohol re-usable masters for microneedles replication
-
Matteucci, M.; Fanetti, M.; Casella, M.; Gramatica, F.; Gavioli, L.; Tormen, M.; Grenci, G.; Angelis, F.D.; Fabrizio, E.D. Poly vinyl alcohol re-usable masters for microneedles replication. Microelectron. Eng. 2009, 86, 752-756.
-
(2009)
Microelectron. Eng.
, vol.86
, pp. 752-756
-
-
Matteucci, M.1
Fanetti, M.2
Casella, M.3
Gramatica, F.4
Gavioli, L.5
Tormen, M.6
Grenci, G.7
Angelis, F.D.8
Fabrizio, E.D.9
-
186
-
-
60849112814
-
Improvement in antigen-delivery using fabrication of a grooves-embedded microneedle array
-
Han, M.H.; Kim, D.K.; Kang, S.H.; Yoon, H.R.; Kim, B.Y.; Lee, S.S.; Kim, K.D.; Lee, H.G. Improvement in antigen-delivery using fabrication of a grooves-embedded microneedle array. Sens. Actuators B 2009, 137, 274-280.
-
(2009)
Sens. Actuators B
, vol.137
, pp. 274-280
-
-
Han, M.H.1
Kim, D.K.2
Kang, S.H.3
Yoon, H.R.4
Kim, B.Y.5
Lee, S.S.6
Kim, K.D.7
Lee, H.G.8
-
187
-
-
70549093175
-
Mass producible and biocompatible microneedle patch and functional verification of its usefulness for transdermal drug delivery
-
Jin, C.Y.; Han, M.H.; Lee, S.S. Mass producible and biocompatible microneedle patch and functional verification of its usefulness for transdermal drug delivery. Biomed. Microdevices 2009, 11, 1195-1203.
-
(2009)
Biomed. Microdevices
, vol.11
, pp. 1195-1203
-
-
Jin, C.Y.1
Han, M.H.2
Lee, S.S.3
-
188
-
-
38349107723
-
A novel microdevice for the treatment of hydrocephalus: Design and fabrication of an array of microvales and microneedles
-
Emam, M.; Abashiya, Y.; Chareunsack, B.; Skordos, J.; Oh, J.H.; Choi, Y.; Kralick, F.; Noh, H. A novel microdevice for the treatment of hydrocephalus: design and fabrication of an array of microvales and microneedles. Microsyst. Technol. 2008, 14, 371-378.
-
(2008)
Microsyst. Technol.
, vol.14
, pp. 371-378
-
-
Emam, M.1
Abashiya, Y.2
Chareunsack, B.3
Skordos, J.4
Oh, J.H.5
Choi, Y.6
Kralick, F.7
Noh, H.8
-
189
-
-
34548126886
-
Fabrication of Microneedles
-
In, Bangkok, Thailand, 16-19 January
-
Hsu, C.C.; Chen, Y.T.; Tsai, C.H.; Kangl, S.W. Fabrication of Microneedles. In Proceedings of 2nd IEEE International Conference on Nano/Micro Engineered and Molicular System, Bangkok, Thailand, 16-19 January 2007; pp. 639-642.
-
(2007)
Proceedings of 2nd IEEE International Conference on Nano/Micro Engineered and Molicular System
, pp. 639-642
-
-
Hsu, C.C.1
Chen, Y.T.2
Tsai, C.H.3
Kangl, S.W.4
-
190
-
-
76749169710
-
Formulation and coating of microneedles with inactivated influenza virus to improve vaccine stability and immunogenicity
-
Kim, Y.C.; Quan, F.S.; Compans, R.W.; Kang, S.M.; Prausnitz, M.R. Formulation and coating of microneedles with inactivated influenza virus to improve vaccine stability and immunogenicity. J. Control. Release 2010, 142, 187-195.
-
(2010)
J. Control. Release
, vol.142
, pp. 187-195
-
-
Kim, Y.C.1
Quan, F.S.2
Compans, R.W.3
Kang, S.M.4
Prausnitz, M.R.5
-
191
-
-
76949106929
-
Micromachning of a newly designed AFM probe integrated with hollow microneedle for cellular function analysis
-
Kato, N.; Kawashima, T.; Shibata, T.; Mineta, T.; Makino, E. Micromachning of a newly designed AFM probe integrated with hollow microneedle for cellular function analysis. Microelectr. Eng. 2010, 87, 1185-1189.
-
(2010)
Microelectr. Eng.
, vol.87
, pp. 1185-1189
-
-
Kato, N.1
Kawashima, T.2
Shibata, T.3
Mineta, T.4
Makino, E.5
-
192
-
-
50249101742
-
On A Microfabricated Ti-alloy-based Microneedle Array for Transdermal Drug Delivery
-
In, Sanya, China, 6-9 January
-
Hou, W.; Das, B.; Jiang, Y.; Qian, S.; Zheng, X.; Yang, J.; Pi, X.; Liu, H.; Zheng, J.; Zhang, Y. On A Microfabricated Ti-alloy-based Microneedle Array for Transdermal Drug Delivery, In Proceedings of 3rd IEEE International Conference on Nano/Micro Engineered and Molecular System, Sanya, China, 6-9 January 2008; pp. 453-456.
-
(2008)
Proceedings of 3rd IEEE International Conference on Nano/Micro Engineered and Molecular System
, pp. 453-456
-
-
Hou, W.1
Das, B.2
Jiang, Y.3
Qian, S.4
Zheng, X.5
Yang, J.6
Pi, X.7
Liu, H.8
Zheng, J.9
Zhang, Y.10
-
193
-
-
38049146196
-
Characterization of Solid Maltose Microneedles and their Use for Transdermal Delivery
-
Kolli, C.S.; Banga, A.K. Characterization of Solid Maltose Microneedles and their Use for Transdermal Delivery. Pharm. Res. 2008, 25, 104-113.
-
(2008)
Pharm. Res.
, vol.25
, pp. 104-113
-
-
Kolli, C.S.1
Banga, A.K.2
-
194
-
-
42749084964
-
Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method
-
Verbaan, F.J.; Bal, S.M.; van den Berg, d.j.; Dijksman, J.A.; van Hecke, M.; Verpoorten, H.; van den Berg, A.; Luttge, R.; Bouwstra, J.A. Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method. J. Control. Release 2008, 128, 80-88.
-
(2008)
J. Control. Release
, vol.128
, pp. 80-88
-
-
Verbaan, F.J.1
Bal, S.M.2
van den Berg, D.J.3
Dijksman, J.A.4
van Hecke, M.5
Verpoorten, H.6
van den Berg, A.7
Luttge, R.8
Bouwstra, J.A.9
-
195
-
-
33845773955
-
High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector
-
Kim, K.; Lee, J.; High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector. Microsyst. Technol. 2007, 13, 231-235.
-
(2007)
Microsyst. Technol.
, vol.13
, pp. 231-235
-
-
Kim, K.1
Lee, J.2
-
196
-
-
0004253046
-
-
4th ed.; Prentice Hall: Upper Saddle River, NJ, USA
-
Gere, J.; Timoshenko, S. Mechanics of Materials, 4th ed.; Prentice Hall: Upper Saddle River, NJ, USA, 1999.
-
(1999)
Mechanics of Materials
-
-
Gere, J.1
Timoshenko, S.2
-
197
-
-
0008670190
-
Micro fabricated polysilicon microneedles for minimally invasive biomedical devices
-
Zahn, J.D.; Talbot, N.H.; Liepmann, D.; Pisano, A.P. Micro fabricated polysilicon microneedles for minimally invasive biomedical devices. Biomed. Microdevices 2000, 2, 295-303.
-
(2000)
Biomed. Microdevices
, vol.2
, pp. 295-303
-
-
Zahn, J.D.1
Talbot, N.H.2
Liepmann, D.3
Pisano, A.P.4
-
198
-
-
4344712955
-
Geomertrical effects in mechanical characterizing of microneedle for biomedical applications
-
Aggarwal, P.; Johnston, C.R. Geomertrical effects in mechanical characterizing of microneedle for biomedical applications. Sens. Actuators B 2004, 102, 226-234.
-
(2004)
Sens. Actuators B
, vol.102
, pp. 226-234
-
-
Aggarwal, P.1
Johnston, C.R.2
-
199
-
-
0034888339
-
Resistance forces acting on suture needles
-
Frick, T.B.; Maruccia, D.D.; Cartmill, J.A.; Martin, C.J.; Walsh, W.R. Resistance forces acting on suture needles. J. Biomech. 2001, 34, 1335-1340.
-
(2001)
J. Biomech.
, vol.34
, pp. 1335-1340
-
-
Frick, T.B.1
Maruccia, D.D.2
Cartmill, J.A.3
Martin, C.J.4
Walsh, W.R.5
-
200
-
-
33845761961
-
Geometrical Strengthening and tip-sharping of a microneedle array fabricated by X-ray lithography
-
Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S. Geometrical Strengthening and tip-sharping of a microneedle array fabricated by X-ray lithography. Microsyst. Technol. 2007, 13, 209-214.
-
(2007)
Microsyst. Technol.
, vol.13
, pp. 209-214
-
-
Khumpuang, S.1
Horade, M.2
Fujioka, K.3
Sugiyama, S.4
-
201
-
-
18744377499
-
Hollow metal microneedles for insulin delivery to diabetic rats
-
Davis, S.P.; Martanto, W.; Allen, M.G.; Prausnitz, M.R. Hollow metal microneedles for insulin delivery to diabetic rats. IEEE Trans. Biomed. Eng. 2005, 52, 909-915.
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, pp. 909-915
-
-
Davis, S.P.1
Martanto, W.2
Allen, M.G.3
Prausnitz, M.R.4
-
202
-
-
78149425158
-
MEMS based Polymeric Drug Delivery System
-
In, Toronto, Canada, 21-24 August
-
Ashraf, M.W.; Tayyaba, S.; Afzulpurkar, N. MEMS based Polymeric Drug Delivery System. In Proceedings of 6th IEEE Conference on Automation Science and Engineering (CASE), Toronto, Canada, 21-24 August 2010; pp. 192-197.
-
(2010)
Proceedings of 6th IEEE Conference on Automation Science and Engineering (CASE)
, pp. 192-197
-
-
Ashraf, M.W.1
Tayyaba, S.2
Afzulpurkar, N.3
-
203
-
-
14744302241
-
A unique fabrication approach for microneedles using coherent porous silicon technology
-
Rajaraman, S.; Henderson, H.T. A unique fabrication approach for microneedles using coherent porous silicon technology. Sens. Actuators B 2005, 105, 443-448.
-
(2005)
Sens. Actuators B
, vol.105
, pp. 443-448
-
-
Rajaraman, S.1
Henderson, H.T.2
-
204
-
-
33847301400
-
Polymeric microneedle fabrication using a microinjection molding technique
-
Sammoura, F.; Kang, J.; Heo, Y.; Jung, T.; Lin, L. Polymeric microneedle fabrication using a microinjection molding technique. Microsyst. Technol. 2007, 13, 517-522.
-
(2007)
Microsyst. Technol.
, vol.13
, pp. 517-522
-
-
Sammoura, F.1
Kang, J.2
Heo, Y.3
Jung, T.4
Lin, L.5
-
205
-
-
78649802326
-
Improved DNA vaccination by skin-targeted delivery using dry-coated densely-packed microprojection arrays
-
Chen, X.; Kask, A.S.; Crichton, M.L.; McNeilly, C.; Yukiko, S.; Dong, L.; Marshak, J.O.; Jarrahian, C.; Fernando, G.J.P.; Chen, D.; Koelle, D.M.; Kendall, M.A.F. Improved DNA vaccination by skin-targeted delivery using dry-coated densely-packed microprojection arrays. J. Control. Release 2010, 148, 327-333.
-
(2010)
J. Control. Release
, vol.148
, pp. 327-333
-
-
Chen, X.1
Kask, A.S.2
Crichton, M.L.3
McNeilly, C.4
Yukiko, S.5
Dong, L.6
Marshak, J.O.7
Jarrahian, C.8
Fernando, G.J.P.9
Chen, D.10
Koelle, D.M.11
Kendall, M.A.F.12
-
206
-
-
77955307328
-
In vitro permeation of a pegylated naltrexone prodrug across microneedle-treated skin
-
Milewski, M.; Yerramreddy, T.R.; Ghosh, P.; Crooks, P.A.; Stinchcomb, A.L. In vitro permeation of a pegylated naltrexone prodrug across microneedle-treated skin. J. Control. Release 2010, 146, 37-44.
-
(2010)
J. Control. Release
, vol.146
, pp. 37-44
-
-
Milewski, M.1
Yerramreddy, T.R.2
Ghosh, P.3
Crooks, P.A.4
Stinchcomb, A.L.5
-
207
-
-
78650593789
-
Variation in microneedle geometry to increase the shear strength
-
Khann, P.; Silv, H.; Bhansali, S. Variation in microneedle geometry to increase the shear strength. Proc. Eng. 2010, 5, 977-980.
-
(2010)
Proc. Eng.
, vol.5
, pp. 977-980
-
-
Khann, P.1
Silv, H.2
Bhansali, S.3
-
208
-
-
77957019574
-
Influence of microneedle shape on the transport of a fluorescent dye into human skin in vivo
-
Bal, S.M.; Kruithof, A.C.; Zwier, R.; Dietz, E.; Bouwstra, J.A.; Lademann, J.; Meinke, M.C. Influence of microneedle shape on the transport of a fluorescent dye into human skin in vivo. J. Control. Release 2010, 147, 218-224.
-
(2010)
J. Control. Release
, vol.147
, pp. 218-224
-
-
Bal, S.M.1
Kruithof, A.C.2
Zwier, R.3
Dietz, E.4
Bouwstra, J.A.5
Lademann, J.6
Meinke, M.C.7
-
209
-
-
78049472743
-
Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution
-
Donnelly, R.F.; Garland, M.J.; Morrow, D.I.J.; Migalska, K.; Singh, T.R.R.; Majithiya, R.; Woolfson, A.D. Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution. J. Control. Release 2010, 147, 333-341.
-
(2010)
J. Control. Release
, vol.147
, pp. 333-341
-
-
Donnelly, R.F.1
Garland, M.J.2
Morrow, D.I.J.3
Migalska, K.4
Singh, T.R.R.5
Majithiya, R.6
Woolfson, A.D.7
-
210
-
-
77950044549
-
The effect of strain rate on the precision of penetration of short densely-packed microprojection array patches coated with vaccine
-
Crichton, M.L.; Ansaldo, A.; Chen, X.; Prowa, T.W.; Fernando, G.J.P.; Kendall, M.A.F. The effect of strain rate on the precision of penetration of short densely-packed microprojection array patches coated with vaccine. Biomaterials 2010, 31, 4562-4572.
-
(2010)
Biomaterials
, vol.31
, pp. 4562-4572
-
-
Crichton, M.L.1
Ansaldo, A.2
Chen, X.3
Prowa, T.W.4
Fernando, G.J.P.5
Kendall, M.A.F.6
-
211
-
-
77955509491
-
Influenza virus-like particles coated onto microneedles can elicit stimulatory effects on Langerhans cells in human skin
-
Pearton, M.; Kang, S.M.; Song, J.M.; Kim, Y.C.; Quan, F.S.; Anstey, A.; Ivory, M.; Prausnitz, M.R.; Compans, R.W.; Birchall, J.C. Influenza virus-like particles coated onto microneedles can elicit stimulatory effects on Langerhans cells in human skin. Vaccine 2010, 28, 6104-6113.
-
(2010)
Vaccine
, vol.28
, pp. 6104-6113
-
-
Pearton, M.1
Kang, S.M.2
Song, J.M.3
Kim, Y.C.4
Quan, F.S.5
Anstey, A.6
Ivory, M.7
Prausnitz, M.R.8
Compans, R.W.9
Birchall, J.C.10
-
212
-
-
77349091986
-
Super-short solid silicon microneedles for transdermal drug delivery applications international
-
Li, W.-Z.; Hou, M.-R.; Zhou, J.-P.; Zhou, Y.-Q.; Hao, B.-H.; Liu, T.; Zhang, Y. Super-short solid silicon microneedles for transdermal drug delivery applications international. J. Pharm. 2010, 389, 122-129.
-
(2010)
J. Pharm.
, vol.389
, pp. 122-129
-
-
Li, W.-Z.1
Hou, M.-R.2
Zhou, J.-P.3
Zhou, Y.-Q.4
Hao, B.-H.5
Liu, T.6
Zhang, Y.7
-
214
-
-
77955983468
-
Transdermal drug delivery by in-skin electroporation using a microneedle array
-
Yan, K.; Todo, H.; Sugibayashi, K. Transdermal drug delivery by in-skin electroporation using a microneedle array. Int. J. Pharm. 2010, 397, 77-83.
-
(2010)
Int. J. Pharm.
, vol.397
, pp. 77-83
-
-
Yan, K.1
Todo, H.2
Sugibayashi, K.3
-
215
-
-
77952886320
-
Evaluation needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery
-
Yan, G.; Warner, K.S.; Zhang, J.; Sharma, S.; Gale, B.K. Evaluation needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery. Int. J. Pharm. 2010, 391, 7-12.
-
(2010)
Int. J. Pharm.
, vol.391
, pp. 7-12
-
-
Yan, G.1
Warner, K.S.2
Zhang, J.3
Sharma, S.4
Gale, B.K.5
-
216
-
-
77958150939
-
Improve protection against avian influenza H5N1 virus by a single vaccination with virus-like particles in skin using microneedles
-
Song, J.M.; Kim, Y.C.; Barlow, P.G.; Hossain, M.J.; Park, K.M.; Donis, R.O.; Prausnitz, M.R.; Compans, R.W.; Kang, S.M. Improve protection against avian influenza H5N1 virus by a single vaccination with virus-like particles in skin using microneedles. Antivir. Res. 2010, 88, 244-247.
-
(2010)
Antivir. Res.
, vol.88
, pp. 244-247
-
-
Song, J.M.1
Kim, Y.C.2
Barlow, P.G.3
Hossain, M.J.4
Park, K.M.5
Donis, R.O.6
Prausnitz, M.R.7
Compans, R.W.8
Kang, S.M.9
-
217
-
-
77952744825
-
Transdermal delivery of insulin using microneedle rollers in vivo
-
Zhou, C.P.; Liu, Y.L.; Wang, H.L.; Zhang, P.X.; Zhang, J.L. Transdermal delivery of insulin using microneedle rollers in vivo. Int. J. Pharm. 2010, 392, 127-133.
-
(2010)
Int. J. Pharm.
, vol.392
, pp. 127-133
-
-
Zhou, C.P.1
Liu, Y.L.2
Wang, H.L.3
Zhang, P.X.4
Zhang, J.L.5
-
218
-
-
78049454969
-
Dose sparing enabled by skin immunization with influenza virus-like particle vaccine using microneedles
-
Quan, F.S.; Kim, Y.C.; Compans, R.W.; Prausnitz, M.R.; Kang, S.M. Dose sparing enabled by skin immunization with influenza virus-like particle vaccine using microneedles. J. Control. Release 2010, 147, 326-332.
-
(2010)
J. Control. Release
, vol.147
, pp. 326-332
-
-
Quan, F.S.1
Kim, Y.C.2
Compans, R.W.3
Prausnitz, M.R.4
Kang, S.M.5
-
219
-
-
0035209251
-
Pulsatile drug delivery systems
-
Bussemer, T.; Otto, I.; Bodmeier, R. Pulsatile drug delivery systems. Crit. Rev. Ther. Drug Carrier Syst. 2001, 18, 433-458.
-
(2001)
Crit. Rev. Ther. Drug Carrier Syst.
, vol.18
, pp. 433-458
-
-
Bussemer, T.1
Otto, I.2
Bodmeier, R.3
-
220
-
-
60449115335
-
Development of an OAPCP-micropump liquid cooling system in a laptop
-
Ma, H.K.; Chen, B.R.; Gao, J.J.; Lin, C.Y. Development of an OAPCP-micropump liquid cooling system in a laptop. Int. Commun. Heat Mass Transf. 2009, 36, 225-232.
-
(2009)
Int. Commun. Heat Mass Transf.
, vol.36
, pp. 225-232
-
-
Ma, H.K.1
Chen, B.R.2
Gao, J.J.3
Lin, C.Y.4
-
221
-
-
29144530170
-
Electroactive polymer based microfluidic pump
-
Xia, F.; Tadigadapa, S.; Zhang, Q.M. Electroactive polymer based microfluidic pump. Sens. Actuators A 2006, 125, 346-352.
-
(2006)
Sens. Actuators A
, vol.125
, pp. 346-352
-
-
Xia, F.1
Tadigadapa, S.2
Zhang, Q.M.3
-
222
-
-
34047227032
-
Fabrication and drive test of pneumatic PDMS micro pump
-
Jeong, O.C.; Konishi, S.; Fabrication and drive test of pneumatic PDMS micro pump. Sens. Actuators A 2007, 135, 849-856.
-
(2007)
Sens. Actuators A
, vol.135
, pp. 849-856
-
-
Jeong, O.C.1
Konishi, S.2
-
223
-
-
43049119081
-
Micropump with TiNi shape memory diaphragm actuator
-
Makino, E.; Shibata, T. Micropump with TiNi shape memory diaphragm actuator. J. Surface Finish. Soc. Jpn. 2005, 56, 213-218.
-
(2005)
J. Surface Finish. Soc. Jpn.
, vol.56
, pp. 213-218
-
-
Makino, E.1
Shibata, T.2
-
224
-
-
78650361129
-
MEMS based System for Drug Delivery
-
In, Islamabad, Pakistan, 18-19 October
-
Ashraf, M. W.; Tayyaba, S.; Nisar, A.; Afzulpurkar, N. MEMS based System for Drug Delivery. In Proceedings of 6th International Conference on Emerging Technologies (ICET), Islamabad, Pakistan, 18-19 October, 2010; pp. 82-87.
-
(2010)
Proceedings of 6th International Conference on Emerging Technologies (ICET)
, pp. 82-87
-
-
Ashraf, M.W.1
Tayyaba, S.2
Nisar, A.3
Afzulpurkar, N.4
-
225
-
-
33847309199
-
Microsystem for Injection of Insulin and Monitoring of Glucose Concentration
-
In, Irvine, CA, USA, 30 October-3 November
-
Kabata, A.; Suzuki, H. Microsystem for Injection of Insulin and Monitoring of Glucose Concentration. In Proceedings of 5th International Conference on Sensors, Irvine, CA, USA, 30 October-3 November 2005; pp. 171-174.
-
(2005)
Proceedings of 5th International Conference on Sensors
, pp. 171-174
-
-
Kabata, A.1
Suzuki, H.2
-
226
-
-
71449120273
-
An Electrolysis-bubble-actuated micropump using electrowetting on dielectric (EWOD) for 1XN micro-sample switches
-
In, Denver, CO, USA, 21-25 June
-
Yang, S.C.; Liu, C.H. An Electrolysis-bubble-actuated micropump using electrowetting on dielectric (EWOD) for 1XN micro-sample switches. In Proceedings of Transducers, Denver, CO, USA, 21-25 June 2009; pp. 2018-2021.
-
(2009)
Proceedings of Transducers
, pp. 2018-2021
-
-
Yang, S.C.1
Liu, C.H.2
-
227
-
-
33845584145
-
A PZT Insulin Pump Integrated with a Silicon Micro Needle Array for Transdermal Drug Delivery
-
In, San Diego, CA, USA, 30 May-2 June
-
Ma, B.; Liu, S.; Gan, Z.; Liu, G.; Cai, X.; Zhang, H.; Yang, Z. A PZT Insulin Pump Integrated with a Silicon Micro Needle Array for Transdermal Drug Delivery. In Proceedings of 56th Electronic Components and Technology Conference, San Diego, CA, USA, 30 May-2 June 2006; pp. 667-681.
-
(2006)
Proceedings of 56th Electronic Components and Technology Conference
, pp. 667-681
-
-
Ma, B.1
Liu, S.2
Gan, Z.3
Liu, G.4
Cai, X.5
Zhang, H.6
Yang, Z.7
-
228
-
-
78649263298
-
Design and Simulation of Double Lumen Polymeric Microneedles for Blood Transport
-
In, Singapore, 10-12 September
-
Tayyaba, S.; Ashraf, M.W.; Afzulpurkar, N. Design and Simulation of Double Lumen Polymeric Microneedles for Blood Transport. In Proceedings of International Conference on Mechanical and Electrical Technology (ICMET), Singapore, 10-12 September 2010; pp. 615-618.
-
(2010)
Proceedings of International Conference on Mechanical and Electrical Technology (ICMET)
, pp. 615-618
-
-
Tayyaba, S.1
Ashraf, M.W.2
Afzulpurkar, N.3
-
229
-
-
0042564493
-
Micropackaging technologies for integrated microsystems: Applications to MEMS and MOEMS
-
doi:10.1117/12.484953
-
Najafi, K. Micropackaging technologies for integrated microsystems: Applications to MEMS and MOEMS. Proc. SPIE 2003, 4979, doi:10.1117/12.484953.
-
(2003)
Proc. SPIE
, vol.4979
-
-
Najafi, K.1
-
230
-
-
84855986043
-
-
Available online:, (accessed on 27 April 2011)
-
3M. Available online: http://solutions.3m.com/wps/portal/3M/en_WW/DrugDeliverySystems/DDSD (accessed on 27 April 2011).
-
3M
-
-
-
231
-
-
78651228601
-
Microneedles in clinical practice-an exploratory study into the opinions of healthcare professionals and the public
-
Birchall, J.C.; Clemo, R.; Anstey, A.; John, D.N. Microneedles in clinical practice-an exploratory study into the opinions of healthcare professionals and the public. Pharm. Res. 2011, 28, 95-106.
-
(2011)
Pharm. Res.
, vol.28
, pp. 95-106
-
-
Birchall, J.C.1
Clemo, R.2
Anstey, A.3
John, D.N.4
|