Volumn 165, Issue 1, 2011, Pages 86-93

A novel thermo-pneumatic peristaltic micropump with low temperature elevation on working fluid

Author keywords

MEMS; Microfluidic device; Micropump; Peristaltic; Thermo pneumatic

Indexed keywords

APPLIED VOLTAGES; CONVENTIONAL DESIGN; DNA CHIP; LOW TEMPERATURES; MICRO PUMP; MICRO-FLUIDIC DEVICES; MICROMACHINING TECHNIQUES; OPERATIONAL CONDITIONS; PERISTALTIC; PERISTALTIC MICROPUMPS; POINT OF CARE; PROTEIN CHIP; PUMPING AREA; PUMPING PERFORMANCE; SMALL SIZE; TEMPERATURE ELEVATION; THERMO-PNEUMATIC; WORKING FLUID;

EID: 79951773017     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2010.02.018     Document Type: Conference Paper
Times cited : (62)

References (22)
  • 1
    • 34447299421 scopus 로고    scopus 로고
    • Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
    • DOI 10.1016/j.biotechadv.2007.05.003, PII S0734975007000687
    • C. Zang, D. Xing, and Y. Li Micropumps, microvalves, and micromixers within PCR microfluidic chips: advances and trends Biotechnol. Adv. 25 2007 483 514 (Pubitemid 47049789)
    • (2007) Biotechnology Advances , vol.25 , Issue.5 , pp. 483-514
    • Zhang, C.1    Xing, D.2    Li, Y.3
  • 4
    • 52649112314 scopus 로고    scopus 로고
    • A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump
    • N.J. Graf, and M.T. Bowser A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump Lab Chip 8 2008 1664 1670
    • (2008) Lab Chip , vol.8 , pp. 1664-1670
    • Graf, N.J.1    Bowser, M.T.2
  • 6
    • 14744282731 scopus 로고    scopus 로고
    • Fabrication and characterization of a bidirectional valveless peristaltic micropump and its application to a flow-type immunoanalysis
    • DOI 10.1016/j.snb.2004.04.081, PII S0925400504002667, The 17th European Conference on Solid-State Transducers, University of Minho, Guimares, Portugal, September 21-24, 2003
    • D.-S. Lee, H.C. Yoon, and J.S. Ko Fabrication and characterization of a bidirectional valveless peristaltic micropump and its application to a flow-type immunoanalysis Sens. Actuat. B 103 2004 409 415 (Pubitemid 40329238)
    • (2004) Sensors and Actuators, B: Chemical , vol.103 , Issue.1-2 , pp. 409-415
    • Lee, D.-S.1    Yoon, H.C.2    Ko, J.S.3
  • 7
    • 59949084950 scopus 로고    scopus 로고
    • Effect of actuation sequence on flow rates of peristaltic micropumps with PZT actuators
    • L.-S. Jang, K. Shu, Y.-C. Yu, Y.-J. Li, and C.-H. Chen Effect of actuation sequence on flow rates of peristaltic micropumps with PZT actuators Biomed. Microdevices 11 2009 173 181
    • (2009) Biomed. Microdevices , vol.11 , pp. 173-181
    • Jang, L.-S.1    Shu, K.2    Yu, Y.-C.3    Li, Y.-J.4    Chen, C.-H.5
  • 8
    • 58149181346 scopus 로고    scopus 로고
    • Optimization design of multi-material micropump using finite element method
    • M. Zhu, P. Kirby, M. Wacklerle, M. Herz, and M. Richter Optimization design of multi-material micropump using finite element method Sens. Actuat. A 149 2009 130 135
    • (2009) Sens. Actuat. A , vol.149 , pp. 130-135
    • Zhu, M.1    Kirby, P.2    Wacklerle, M.3    Herz, M.4    Richter, M.5
  • 9
    • 42549155224 scopus 로고    scopus 로고
    • A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistance
    • S.B. Huang, M.H. Wu, Z. Cui, and G.B. Lee A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistance J. Micromech. Microeng. 18 2008 045008
    • (2008) J. Micromech. Microeng. , vol.18 , pp. 045008
    • Huang, S.B.1    Wu, M.H.2    Cui, Z.3    Lee, G.B.4
  • 10
    • 0034615958 scopus 로고    scopus 로고
    • Monolithic microfabricated valves and pumps by multilayer soft lithography
    • DOI 10.1126/science.288.5463.113
    • M.A. Unger, H.-P. Chou, T. Thorsen, A. Scherer, and S.R. Quake Monolithic microfabricated valves and pumps by multilater soft lithography Science 288 2000 113 116 (Pubitemid 30203039)
    • (2000) Science , vol.288 , Issue.5463 , pp. 113-116
    • Unger, M.A.1    Chou, H.-P.2    Thorsen, T.3    Scherer, A.4    Quake, S.R.5
  • 15
    • 69749094726 scopus 로고    scopus 로고
    • Design and simulation of a novel electrostatic peristaltic micromachined pump for drug delivery applications
    • M.M. Teymoori, and E. Abbaspour-Sani Design and simulation of a novel electrostatic peristaltic micromachined pump for drug delivery applications Sens. Actuat. A 117 2005 222 229
    • (2005) Sens. Actuat. A , vol.117 , pp. 222-229
    • Teymoori, M.M.1    Abbaspour-Sani, E.2
  • 19
  • 20
    • 61849164047 scopus 로고    scopus 로고
    • Development and characterization of thermopneumatic peristaltic micropumps
    • Y.-J. Yang, and H.-H. Liao Development and characterization of thermopneumatic peristaltic micropumps J. Micromech. Microeng. 19 2009 025003
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 025003
    • Yang, Y.-J.1    Liao, H.-H.2
  • 22
    • 62249096225 scopus 로고    scopus 로고
    • Current micropump technologies and their biomedical applications
    • F. Amirouche, Y. Zhou, and T. Johnson Current micropump technologies and their biomedical applications Microsyst. Technol. 15 2009 647 666
    • (2009) Microsyst. Technol. , vol.15 , pp. 647-666
    • Amirouche, F.1    Zhou, Y.2    Johnson, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.