메뉴 건너뛰기




Volumn , Issue , 2010, Pages 82-87

MEMS based system for drug delivery

Author keywords

Finite element analysis; Hollow silicon microneedles; Piezoelectric micropump; Transdermal drug delivery

Indexed keywords

CONTROL ELECTRONICS; DRUG DELIVERY SYSTEM; ESSENTIAL COMPONENT; FINITE ELEMENT ANALYSIS; FLUID FLOW; FLUID SOLIDS; HOLLOW SILICON MICRONEEDLES; MECHANICAL STRENGTH; MICRO PUMP; MICRO-ELECTRO-MECHANICAL; MICRONEEDLES; NEW DESIGN; OPERATIONAL PARAMETERS; OUT-OF-PLANE; PIEZOELECTRIC MICROPUMPS; SILICON MICRONEEDLES; TRANSDERMAL DRUG DELIVERY; TRANSDERMAL DRUG DELIVERY SYSTEMS; VALVELESS MICROPUMPS;

EID: 78650361129     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICET.2010.5638375     Document Type: Conference Paper
Times cited : (6)

References (16)
  • 2
    • 1542358759 scopus 로고    scopus 로고
    • Microneedles for transdermal drug delivery
    • M. R. Prausnitz, "Microneedles for transdermal drug delivery", Adv Drug Deliv Rev 56:581-587, 2004.
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 581-587
    • Prausnitz, M.R.1
  • 3
    • 0028806620 scopus 로고
    • Genetic transformation of nematodes using arrays of micromechanical piercing structures
    • S. Hashmi, "Genetic transformation of nematodes using arrays of micromechanical piercing structures", BioTechniques 19, pp, 766-770, 1995.
    • (1995) BioTechniques , vol.19 , pp. 766-770
    • Hashmi, S.1
  • 4
    • 0031852494 scopus 로고    scopus 로고
    • Microfabricated microneedles: A novel method to increase transdermal drug delivery
    • S. Henry, "Microfabricated microneedles: a novel method to increase transdermal drug delivery", J. Pharm. Sci. 87, pp. 922-925, 1998.
    • (1998) J. Pharm. Sci. , vol.87 , pp. 922-925
    • Henry, S.1
  • 5
    • 0026205082 scopus 로고
    • A silicon-based, threedimensional neural interface: Manufacturing processes for an intracortical electrode array
    • P. K Campbell, K. E. Jones, R. J. Huber, K. W. Horch and R. A. Normann, "A silicon-based, threedimensional neural interface: manufacturing processes for an intracortical electrode array", IEEE Trans Biomed Eng 38(8), pp.758-768, 1991.
    • (1991) IEEE Trans Biomed Eng , vol.38 , Issue.8 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 6
    • 0032598155 scopus 로고    scopus 로고
    • Optimization design of a piezoelectric micropump
    • Mu YH, Hung NP, Ngoi KA., "Optimization design of a piezoelectric micropump", Int JAdv Manuf Technol., 15, pp. 573-6., 1999
    • (1999) Int JAdv Manuf Technol. , vol.15 , pp. 573-576
    • Mu, Y.H.1    Hung, N.P.2    Ngoi, K.A.3
  • 7
    • 0035980452 scopus 로고    scopus 로고
    • Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology
    • Cao L, Mantell Susan, Polla Dennis, "Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology",. Sens Actuators A Phys, 94, pp. 117-25, 2001.
    • (2001) Sens Actuators A Phys , vol.94 , pp. 117-25
    • Cao, L.1    Mantell, S.2    Polla, D.3
  • 8
    • 33845713196 scopus 로고    scopus 로고
    • Simulations and analysis of a piezoelectric micropump
    • Wang B, Chu X, Li E, Li L., "Simulations and analysis of a piezoelectric micropump", Ultrasonics, 44, pp. 643-6, 2006.
    • (2006) Ultrasonics , vol.44 , pp. 643-646
    • Wang, B.1    Chu, X.2    Li, E.3    Li, L.4
  • 9
    • 0034251181 scopus 로고    scopus 로고
    • Numerical and experimental studies of flat walled diffuser elements for valveless micropumps
    • Olsson A, and Stemme E., "Numerical and experimental studies of flat walled diffuser elements for valveless micropumps",. Sens Actuators A Phys, 84, pp. 165-75, 2000.
    • (2000) Sens Actuators A Phys , vol.84 , pp. 165-75
    • Olsson, A.1    Stemme, E.2
  • 10
    • 0035975581 scopus 로고    scopus 로고
    • Analytical solutions for the dynamic analysis of a valveless micropump: A membranefluid coupling study
    • Pan L, Nguyen T, Liu GR, Lam KY, Jiang T., "Analytical solutions for the dynamic analysis of a valveless micropump: a membranefluid coupling study", Sens Actuators A Phys, 93, pp.173-81, 2001.
    • (2001) Sens Actuators A Phys , vol.93 , pp. 173-81
    • Pan, L.1    Nguyen, T.2    Liu, G.R.3    Lam, K.Y.4    Jiang, T.5
  • 11
    • 17444378993 scopus 로고    scopus 로고
    • Simulation of piezoelectrically actuated valveless micropump
    • Fan B, Song G, Hussain F., "Simulation of piezoelectrically actuated valveless micropump", J Smart Mater Struct., 14, pp. 400-5. 2005.
    • (2005) J Smart Mater Struct. , vol.14 , pp. 400-405
    • Fan, B.1    Song, G.2    Hussain, F.3
  • 12
    • 34347376804 scopus 로고    scopus 로고
    • Study on a piezoelectric micropump for the controlled drug delivery system
    • Cui Q, Liu C, Xuan F., "Study on a piezoelectric micropump for the controlled drug delivery system", Microfluid Nanofluidics, 3(4) pp.377-90, 2007.
    • (2007) Microfluid Nanofluidics , vol.3 , Issue.4 , pp. 377-390
    • Cui, Q.1    Liu, C.2    Xuan, F.3
  • 15
    • 4344712955 scopus 로고    scopus 로고
    • Geomertrical effects in mechanical characterizing of microneedle for biomedical applications
    • Aggarwal P and Johnston CR (2004) Geomertrical effects in mechanical characterizing of microneedle for biomedical applications. Sens Actuators B 102:226-234
    • (2004) Sens Actuators B , vol.102 , pp. 226-234
    • Aggarwal, P.1    Johnston, C.R.2
  • 16
    • 24944508964 scopus 로고    scopus 로고
    • Silicon microneedle electrode array with temperature monitoring for electroporation
    • N. Wilke, C. Hibert, J. O'Brien, and A. Morrissey, "Silicon microneedle electrode array with temperature monitoring for electroporation", Sensors and Actuators A 123-124, pp. 319- 325, 2005.
    • (2005) Sensors and Actuators A , vol.123-124 , pp. 319-325
    • Wilke, N.1    Hibert, C.2    O'brien, J.3    Morrissey, A.4