1
-
-
0031924387
-
Transdermal drug delivery
-
Apr.
-
Y. N. Kalia, V. Merino, and R. H. Guy, "Transdermal drug delivery," in Dermatol. Clin., Apr. 1998, vol. 16.
-
(1998)
Dermatol. Clin.
, vol.16
-
-
Kalia, Y.N.1
Merino, V.2
Guy, R.H.3
-
2
-
-
0013229597
-
Three-dimensional hollow microneedle and microtube arrays
-
Sendai, Japan
-
D. V. McAllister, F. Cros, S. P. Davis, L. M. Matta, M. R. Prausnitz, and M. G. Allen, "Three-dimensional hollow microneedle and microtube arrays," in Proc. 10th International Conference on Solid-State Sensors and Actuators, Sendai, Japan, 1999.
-
(1999)
Proc. 10th International Conference on Solid-State Sensors and Actuators
-
-
McAllister, D.V.1
Cros, F.2
Davis, S.P.3
Matta, L.M.4
Prausnitz, M.R.5
Allen, M.G.6
-
4
-
-
0038704932
-
Polymer micro needles with through-going capillaries
-
J. M. Ramsey and A. van den Berg, Eds.
-
A. E. Guber, H. D. Dittrich, M. Heckele, D. Herrmann, A. Musilija, W. Pfleging, and Th. Schaller, "Polymer micro needles with through-going capillaries," in Micro Total Analysis Systems 2001, J. M. Ramsey and A. van den Berg, Eds., pp. 155-156.
-
(2001)
Micro Total Analysis Systems 2001
, pp. 155-156
-
-
Guber, A.E.1
Dittrich, H.D.2
Heckele, M.3
Herrmann, D.4
Musilija, A.5
Pfleging, W.6
Schaller, Th.7
-
5
-
-
0037690577
-
Microneedle array for transermal bio-fluid sampling and drug delivery
-
J. M. Ramsey and A. van den Berg, Eds.
-
E. Mukerjee, S. D. Collins, R. L. Smith, and R. Isseroff, "Microneedle array for transermal bio-fluid sampling and drug delivery," in Micro Total Analysis Systems 2001, J. M. Ramsey and A. van den Berg, Eds., pp. 379-380.
-
(2001)
Micro Total Analysis Systems 2001
, pp. 379-380
-
-
Mukerjee, E.1
Collins, S.D.2
Smith, R.L.3
Isseroff, R.4
-
6
-
-
0038366642
-
Integrated micro- and nanofluidics: Silicon revisited
-
J. M. Ramsey and A. van den Berg, Eds.
-
A. van den Berg, "Integrated micro- and nanofluidics: silicon revisited," in Micro Total Analysis Systems 2001, J. M. Ramsey and A. van den Berg, Eds., pp. 207-209.
-
(2001)
Micro Total Analysis Systems 2001
, pp. 207-209
-
-
Van den Berg, A.1
-
7
-
-
0031214943
-
A multichannel neural probe for selective chemical delivery at the cellular level
-
Aug.
-
J. Chen, K. D. Wise, J. F. Hetke, and S. C. Bledsoe Jr., "A multichannel neural probe for selective chemical delivery at the cellular level," IEEE Trans. Biomed. Eng., vol. 44, Aug. 1997.
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
-
-
Chen, J.1
Wise, K.D.2
Hetke, J.F.3
Bledsoe S.C., Jr.4
-
8
-
-
0037980694
-
Polymolding: Two wafer polysilicon micromolding of closed-flow passages for microneedles and microfluidic devices
-
Hilton Head Island, SC
-
N. H. Talbot and A. P. Pisano, "Polymolding: two wafer polysilicon micromolding of closed-flow passages for microneedles and microfluidic devices," in Soil-State Sensor and Actuator Workshop, Hilton Head Island, SC, 1998.
-
(1998)
Soil-State Sensor and Actuator Workshop
-
-
Talbot, N.H.1
Pisano, A.P.2
-
9
-
-
20544449011
-
Microneedles and micro-lancets fabricated using SOI wafers and isotropic etching
-
Boston, MA
-
K. S. Lebouitz and A. P. Pisano, "Microneedles and micro-lancets fabricated using SOI wafers and isotropic etching," in Meet. Electrochem. Soc., Boston, MA, 1998.
-
(1998)
Meet. Electrochem. Soc.
-
-
Lebouitz, K.S.1
Pisano, A.P.2
-
11
-
-
0033230574
-
Micromachined needle array for drug delivery or fluid extraction
-
Nov./Dec.
-
J. D. Brazzle, I. Papautsky, and A. B. Frazier, "Micromachined needle array for drug delivery or fluid extraction," IEEE Eng. Med. Biol., Nov./Dec. 1999.
-
(1999)
IEEE Eng. Med. Biol.
-
-
Brazzle, J.D.1
Papautsky, I.2
Frazier, A.B.3
-
12
-
-
0038029168
-
Silicon, parylene, and silicon/parylene microneedles for strength amd toughness
-
Munich, Germany
-
P. A. Stupar and A. P. Pisano, "Silicon, parylene, and silicon/parylene microneedles for strength amd toughness," in Proc. 11th Int. Conf. on Solid-State Sensors and Actuators, Munich, Germany, 2001.
-
(2001)
Proc. 11th Int. Conf. on Solid-State Sensors and Actuators
-
-
Stupar, P.A.1
Pisano, A.P.2
-
13
-
-
0038029169
-
Fabrication of a micro needle for a trace blood test
-
Munich, Germany
-
K. Oka, S. Aoyagi, Y. Isono, G. Hashiguchi, and H. Fujita, "Fabrication of a micro needle for a trace blood test," in Proc. 11th Int. Conf. on Solid-State Sensors and Actuators, Munich, Germany, 2001.
-
(2001)
Proc. 11th Int. Conf. on Solid-State Sensors and Actuators
-
-
Oka, K.1
Aoyagi, S.2
Isono, Y.3
Hashiguchi, G.4
Fujita, H.5
-
14
-
-
0035279245
-
Micromachined electrodes for biopotential measurements
-
Mar.
-
P. Griss, P. Enoksson, H. K. Tolvanen-Laakso, P. Meriläinen, S. Ollmar, and G. Stemme, "Micromachined electrodes for biopotential measurements," J. Microelectromech. Syst., vol. 10, pp. 10-16, Mar. 2001.
-
(2001)
J. Microelectromech. Syst.
, vol.10
, pp. 10-16
-
-
Griss, P.1
Enoksson, P.2
Tolvanen-Laakso, H.K.3
Meriläinen, P.4
Ollmar, S.5
Stemme, G.6
-
15
-
-
0036141555
-
Micromachined barbed spikes for mechanical chip attachment
-
to be published
-
P. Griss, P. Enoksson, and G. Stemme, "Micromachined barbed spikes for mechanical chip attachment," Sens. Actuators: A Phys., to be published.
-
Sens. Actuators: A Phys.
-
-
Griss, P.1
Enoksson, P.2
Stemme, G.3
-
16
-
-
0038367341
-
-
German patent DE4 241 045
-
F. Larmer and A. Schilp, German patent DE4 241 045.
-
-
-
Larmer, F.1
Schilp, A.2
-
17
-
-
0031177557
-
Microchannels for applications in liquid dosing and flow-rate measurements
-
M. Richter and P. Woias, "Microchannels for applications in liquid dosing and flow-rate measurements," Sens. Actuators: A Phys., vol. 62, 1997.
-
(1997)
Sens. Actuators: A Phys.
, vol.62
-
-
Richter, M.1
Woias, P.2
|