메뉴 건너뛰기




Volumn 10, Issue 3, 2010, Pages 91-108

Design, fabrication and analysis of silicon hollow microneedles for transdermal drug delivery system for treatment of hemodynamic dysfunctions

Author keywords

Computational fluid dynamic (CFD) analysis; Deep reactive ion etching (DRIE); Drug delivery; Hollow silicon microneedle; Multifield analysis; Transdermal drug delivery (TDD)

Indexed keywords

SILICON;

EID: 77958488997     PISSN: 15678822     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10558-010-9100-5     Document Type: Article
Times cited : (71)

References (56)
  • 1
    • 4344712955 scopus 로고    scopus 로고
    • Geometrical effects in mechanical characterizing of microneedle for biomedical applications
    • 10.1016/j.snb.2004.04.024
    • P Aggarwal CR Johnston 2004 Geometrical effects in mechanical characterizing of microneedle for biomedical applications Sens Actuators B 102 226 234 10.1016/j.snb.2004.04.024
    • (2004) Sens Actuators B , vol.102 , pp. 226-234
    • Aggarwal, P.1    Johnston, C.R.2
  • 3
    • 77958456523 scopus 로고
    • ANSI/IEEE Std 176. IEEE standard on piezoelectricity. IEEE
    • ANSI/IEEE Std 176. IEEE standard on piezoelectricity. IEEE; 1987. http://standards.ieee.org/reading/ieee/std-public/description/ultrasonics/ 176-1987-desc.html.
    • (1987)
  • 4
    • 40949162429 scopus 로고    scopus 로고
    • Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis
    • DOI 10.1016/j.sna.2007.06.007, PII S0924424707004499
    • S Aoyagi, et al. 2008 Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis Sens Actuators A 143 20 28 10.1016/j.sna.2007.06.007 (Pubitemid 351417355)
    • (2008) Sensors and Actuators, A: Physical , vol.143 , Issue.1 , pp. 20-28
    • Aoyagi, S.1    Izumi, H.2    Fukuda, M.3
  • 5
    • 55649101168 scopus 로고    scopus 로고
    • Micro-scale devices for transdermal drug delivery
    • 1:CAS:528:DC%2BD1cXhtlOnurjO10.1016/j.ijpharm.2008.08.03218805472
    • A Arora MR Prausnitzc, et al. 2008 Micro-scale devices for transdermal drug delivery Int J Pharm 364 227 236 1:CAS:528:DC%2BD1cXhtlOnurjO 10.1016/j.ijpharm.2008.08.032 18805472
    • (2008) Int J Pharm , vol.364 , pp. 227-236
    • Arora, A.1    Prausnitzc, M.R.2
  • 6
    • 0034902043 scopus 로고    scopus 로고
    • Novel mechanisms and devices to enable successful transdermal drug delivery
    • DOI 10.1016/S0928-0987(01)00167-1, PII S0928098701001671
    • BW Barry 2001 Novel mechanisms and devices to enable successful transdermal drug delivery Eur J Pharm Sci 14 101 114 1:CAS:528: DC%2BD3MXlslGnsLY%3D 10.1016/S0928-0987(01)00167-1 11500256 (Pubitemid 32737532)
    • (2001) European Journal of Pharmaceutical Sciences , vol.14 , Issue.2 , pp. 101-114
    • Barry, B.W.1
  • 8
    • 0022559397 scopus 로고
    • Solid-state electrodes for multichannel multiplexed intracortical neuronal recording
    • 1:STN:280:DyaL287ms1GlsA%3D%3D 10.1109/TBME.1986.325895 3957372
    • SL BeMent, et al. 1986 Solid-state electrodes for multichannel multiplexed intracortical neuronal recording IEEE Trans Biomed Eng 33 2 230 241 1:STN:280:DyaL287ms1GlsA%3D%3D 10.1109/TBME.1986.325895 3957372
    • (1986) IEEE Trans Biomed Eng , vol.33 , Issue.2 , pp. 230-241
    • Bement, S.L.1
  • 9
    • 77649235080 scopus 로고    scopus 로고
    • Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications
    • doi: 10.1007/s10404-009-0467-9
    • Bodhale DW, Nisar A, Afzulpurkar N. Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications. Microfluid Nanofluid. 2009. doi: 10.1007/s10404-009-0467-9.
    • (2009) Microfluid Nanofluid
    • Bodhale, D.W.1    Nisar, A.2    Afzulpurkar, N.3
  • 10
    • 33645286192 scopus 로고    scopus 로고
    • Dermal and transdermal drug delivery systems: Current and future prospects
    • 1:CAS:528:DC%2BD28XislCku70%3D 10.1080/10717540500455975 16556569
    • MB Brown GP Martin, et al. 2006 Dermal and transdermal drug delivery systems: current and future prospects Drug Deliv 13 175 187 1:CAS:528: DC%2BD28XislCku70%3D 10.1080/10717540500455975 16556569
    • (2006) Drug Deliv , vol.13 , pp. 175-187
    • Brown, M.B.1    Martin, G.P.2
  • 11
    • 0035209251 scopus 로고    scopus 로고
    • Pulsatile drug delivery systems
    • 1:CAS:528:DC%2BD3MXptlCqsbg%3D 11763497
    • T Bussemer I Otto R Bodmeier 2001 Pulsatile drug delivery systems Crit Rev Ther Drug Carrier Syst 18 5 433 458 1:CAS:528:DC%2BD3MXptlCqsbg%3D 11763497
    • (2001) Crit Rev Ther Drug Carrier Syst , vol.18 , Issue.5 , pp. 433-458
    • Bussemer, T.1    Otto, I.2    Bodmeier, R.3
  • 12
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
    • 1:STN:280:DyaK38%2FjvFKkug%3D%3D 10.1109/10.83588 1937509
    • PK Campbell, et al. 1991 A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array IEEE Trans Biomed Eng 38 8 758 768 1:STN:280:DyaK38%2FjvFKkug%3D%3D 10.1109/10.83588 1937509
    • (1991) IEEE Trans Biomed Eng , vol.38 , Issue.8 , pp. 758-768
    • Campbell, P.K.1
  • 13
    • 0031214943 scopus 로고    scopus 로고
    • A multichannel neural probe for selective chemical delivery at the cellular level
    • DOI 10.1109/10.605435, PII S0018929497053548
    • J Chen, et al. 1997 A multichannel neural probe for selective chemical delivery at the cellular level IEEE Trans Biomed Eng 44 8 760 769 1:STN:280:DyaK2szpvVyjtg%3D%3D 10.1109/10.605435 9254989 (Pubitemid 27314086)
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.8 , pp. 760-769
    • Chen, J.1    Wise, K.D.2    Hetke, J.F.3    Bledsoe Jr., S.C.4
  • 14
    • 34347376804 scopus 로고    scopus 로고
    • Study on a piezoelectric micropump for the controlled drug delivery system
    • DOI 10.1007/s10404-006-0137-0
    • Q Cui C Liu F Xuan 2007 Study on a piezoelectric micropump for the controlled drug delivery system Microfluid Nanofluidics 3 4 377 390 10.1007/s10404-006-0137-0 (Pubitemid 47023670)
    • (2007) Microfluidics and Nanofluidics , vol.3 , Issue.4 , pp. 377-390
    • Cui, Q.1    Liu, C.2    Zha, X.F.3
  • 15
    • 17444378993 scopus 로고    scopus 로고
    • Simulation of a piezoelectrically actuated valveless micropump
    • DOI 10.1088/0964-1726/14/2/014
    • B Fan G Song F Hussain 2005 Simulation of piezoelectrically actuated valveless micropump J Smart Mater Struct 14 400 405 10.1088/0964-1726/14/2/014 (Pubitemid 40541032)
    • (2005) Smart Materials and Structures , vol.14 , Issue.2 , pp. 400-405
    • Fan, B.1    Song, G.2    Hussain, F.3
  • 16
    • 0034888339 scopus 로고    scopus 로고
    • Resistance forces acting on suture needles
    • DOI 10.1016/S0021-9290(01)00099-9, PII S0021929001000999
    • TB Frick, et al. 2001 Resistance forces acting on suture needles J Biomech 34 1335 1340 1:STN:280:DC%2BD3MvnvFaitA%3D%3D 10.1016/S0021-9290(01) 00099-9 11522313 (Pubitemid 32750643)
    • (2001) Journal of Biomechanics , vol.34 , Issue.10 , pp. 1335-1340
    • Frick, T.B.1    Marucci, D.D.2    Cartmill, J.A.3    Martin, C.J.4    Walsh, W.R.5
  • 17
    • 0742301752 scopus 로고    scopus 로고
    • Silicon micromachined hollow microneedles for transdermal liquid transport
    • Gardeniers HJGE, et al. Silicon micromachined hollow microneedles for transdermal liquid transport. J Microelctromech Syst. 2003;12(6).
    • (2003) J Microelctromech Syst. , vol.12 , Issue.6
    • Hjge, G.1
  • 19
    • 4143098131 scopus 로고    scopus 로고
    • Parameters influencing pulsed flow mixing in microchannels
    • DOI 10.1021/ac049813m
    • I Glasgow S Lieber N Aubry 2004 Parameters influencing pulsed flow mixing in microchannels Anal Chem 76 4825 4832 1:CAS:528:DC%2BD2cXlsVyku7Y%3D 10.1021/ac049813m 15307794 (Pubitemid 39089138)
    • (2004) Analytical Chemistry , vol.76 , Issue.16 , pp. 4825-4832
    • Glasgow, I.1    Lieber, S.2    Aubry, N.3
  • 23
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out of plane microneedles for microfluidics transdermal liquid transfer
    • 10.1109/JMEMS.2003.809959
    • P Griss, et al. 2003 Side-opened out of plane microneedles for microfluidics transdermal liquid transfer J Microelectromech Syst 12 3 296 301 10.1109/JMEMS.2003.809959
    • (2003) J Microelectromech Syst , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1
  • 25
    • 0031699257 scopus 로고    scopus 로고
    • Micro machined needles for the transdermal drug delivery of drugs
    • Henry S, et al. Micro machined needles for the transdermal drug delivery of drugs. In: Proceedings of IEEE workshop MEMS. 1998. p. 494-98.
    • (1998) Proceedings of IEEE Workshop MEMS , pp. 494-498
    • Henry, S.1
  • 26
    • 33845597458 scopus 로고    scopus 로고
    • Modeling and experimental validation of a piezoelectric micropump with novel no-moving-part valves
    • DOI 10.1016/j.sna.2006.01.049, PII S0924424706002913
    • I Izzo D Accoto A Menciassi L Schmitt P Dario 2007 Modelling and experimental validation of a piezoelectric micropump with novel no-moving-part valves Sens Actuators A 133 128 140 10.1016/j.sna.2006.01.049 (Pubitemid 44937595)
    • (2007) Sensors and Actuators, A: Physical , vol.133 , Issue.1 , pp. 128-140
    • Izzo, I.1    Accoto, D.2    Menciassi, A.3    Schmitt, L.4    Dario, P.5
  • 29
    • 0742288421 scopus 로고    scopus 로고
    • Discovery of transdermal penetration enhancers by high-throughput screening
    • DOI 10.1038/nbt928
    • P Karande A Jain, et al. 2004 Discovery of transdermal penetration enhancers by high- throughput screening Nat Biotechnol 22 192 197 1:CAS:528:DC%2BD2cXnvFeisQ%3D%3D 10.1038/nbt928 14704682 (Pubitemid 38160534)
    • (2004) Nature Biotechnology , vol.22 , Issue.2 , pp. 192-197
    • Karande, P.1    Jain, A.2    Mitragotri, S.3
  • 30
    • 84945121522 scopus 로고    scopus 로고
    • Design and fabrication of coupled microneedle array and insertion guide array for safe penetration through skin
    • Khumpuang S, et al. Design and fabrication of coupled microneedle array and insertion guide array for safe penetration through skin. In: International symposium of micromechatronics and human science. 2003.
    • (2003) International Symposium of Micromechatronics and Human Science
    • Khumpuang, S.1
  • 31
    • 2342632586 scopus 로고    scopus 로고
    • A tapered hollow metallic microneedle array using backside exposure of SU-8
    • 1:CAS:528:DC%2BD2cXks1Sitro%3D 10.1088/0960-1317/14/4/021
    • K Kim D Park H Lu K-H Kim JB Lee 2004 A tapered hollow metallic microneedle array using backside exposure of SU-8 J Micromech Microeng 14 597 603 1:CAS:528:DC%2BD2cXks1Sitro%3D 10.1088/0960-1317/14/4/021
    • (2004) J Micromech Microeng , vol.14 , pp. 597-603
    • Kim, K.1    Park, D.2    Lu, H.3    Kim, K.-H.4    Lee, J.B.5
  • 32
    • 77958463966 scopus 로고    scopus 로고
    • A compact and disposable transdermal drug delivery system
    • I-34012 Basovizza-Trieste, Italy
    • Matteucci M, et al. A compact and disposable transdermal drug delivery system. Sincrotrone Trieste, I-34012 Basovizza-Trieste, Italy. 2008.
    • (2008) Sincrotrone Trieste
    • Matteucci, M.1
  • 33
    • 24144465860 scopus 로고    scopus 로고
    • A novel fabrication method of a microneedle array using inclined deep x-ray exposure
    • DOI 10.1088/0960-1317/15/5/002
    • SJ Moon SS Lee 2005 A novel fabrication method of a microneedle array using inclined deep x-ray exposure J Micromech Microeng 15 903 911 1:CAS:528:DC%2BD2MXlslKmtbg%3D 10.1088/0960-1317/15/5/002 (Pubitemid 41237418)
    • (2005) Journal of Micromechanics and Microengineering , vol.15 , Issue.5 , pp. 903-911
    • Moon, S.J.1    Lee, S.S.2
  • 34
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • 10.1016/j.sna.2003.11.008
    • EV Mukherjee, et al. 2004 Microneedle array for transdermal biological fluid extraction and in situ analysis Sens Actuators A 114 267 275 10.1016/j.sna.2003.11.008
    • (2004) Sens Actuators A , vol.114 , pp. 267-275
    • Mukherjee, E.V.1
  • 36
    • 58549089879 scopus 로고    scopus 로고
    • Three dimensional transient multifield analysis of a piezoelectric micropump for drug delivery system for treatment of hemodynamic dysfunctions
    • 10.1007/s10558-008-9060-1 19030990
    • A Nisar N Afzulpurkar A Tuantranont B Mahaisavariya 2008 Three dimensional transient multifield analysis of a piezoelectric micropump for drug delivery system for treatment of hemodynamic dysfunctions Cardiovasc Eng 8 4 203 218 10.1007/s10558-008-9060-1 19030990
    • (2008) Cardiovasc Eng , vol.8 , Issue.4 , pp. 203-218
    • Nisar, A.1    Afzulpurkar, N.2    Tuantranont, A.3    Mahaisavariya, B.4
  • 38
    • 4344679112 scopus 로고    scopus 로고
    • In-plane single-crystal-silicon microneedles for minimally invasive micro fluidic systems
    • 10.1016/j.sna.2003.12.029
    • SJ Paik, et al. 2004 In-plane single-crystal-silicon microneedles for minimally invasive micro fluidic systems Sens Actuators A 114 276 284 10.1016/j.sna.2003.12.029
    • (2004) Sens Actuators A , vol.114 , pp. 276-284
    • Paik, S.J.1
  • 40
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
    • DOI 10.1016/j.jconrel.2005.02.002
    • JH Park MG Allen MR Prausnitz 2005 Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery J Control Release 104 1 51 66 1:CAS:528:DC%2BD2MXjvVClsLg%3D 10.1016/j.jconrel.2005.02.002 15866334 (Pubitemid 40615235)
    • (2005) Journal of Controlled Release , vol.104 , Issue.1 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 41
    • 1542358759 scopus 로고    scopus 로고
    • Microneedles for transdermal drug delivery
    • DOI 10.1016/j.addr.2003.10.023, PII S0169409X03002394
    • MR Prausnitz 2004 Microneedles for transdermal drug delivery Adv Drug Deliv Rev 56 581 587 1:CAS:528:DC%2BD2cXhvFWqsbw%3D 10.1016/j.addr.2003.10.023 15019747 (Pubitemid 38326934)
    • (2004) Advanced Drug Delivery Reviews , vol.56 , Issue.5 , pp. 581-587
    • Prausnitz, M.R.1
  • 42
    • 0028334473 scopus 로고
    • Liposomes and niosomes as topical drug carriers: Dermal and transdermal drug delivery
    • DOI 10.1016/0168-3659(94)90039-6
    • H Schreier J Bouwstra 1994 Liposomes and niosomes as topical drug carriers-dermal and transdermal drug-delivery J Control Release 30 1 15 1:CAS:528:DyaK2cXktFOktbk%3D 10.1016/0168-3659(94)90039-6 (Pubitemid 24173173)
    • (1994) Journal of Controlled Release , vol.30 , Issue.1 , pp. 1-15
    • Schreier, H.1
  • 43
    • 28044473874 scopus 로고    scopus 로고
    • Emerging strategies for the transdermal delivery of peptide and protein drugs
    • DOI 10.1517/17425247.2.3.533
    • YB Schuetz A Naik, et al. 2005 Emerging strategies for the transdermal delivery of peptide and protein drugs Expert Opin Drug Deliv 2 533 548 1:CAS:528:DC%2BD2MXlsFShsbc%3D 10.1517/17425247.2.3.533 16296773 (Pubitemid 41683226)
    • (2005) Expert Opinion on Drug Delivery , vol.2 , Issue.3 , pp. 533-548
    • Schuetz, Y.B.1    Naik, A.2    Guy, R.H.3    Kalia, Y.N.4
  • 44
    • 50049125622 scopus 로고    scopus 로고
    • Fabrication and mechanical characterization of microneedle array for cell surgery
    • Shibata T, et al. Fabrication and mechanical characterization of microneedle array for cell surgery. In: Actuators and microsystems conference. 2007. p. 719-22.
    • (2007) Actuators and Microsystems Conference , pp. 719-722
    • Shibata, T.1
  • 45
    • 84952647272 scopus 로고    scopus 로고
    • Fluid injection through out-of-plane microneedles. Micro technologies in medicine and biology
    • Berkeley, CA
    • Stoeber B, Liepmann D. Fluid injection through out-of-plane microneedles. Micro technologies in medicine and biology. In: 1st annual international conference. Berkeley, CA. 2000.
    • (2000) 1st Annual International Conference
    • Stoeber, B.1    Liepmann, D.2
  • 47
    • 33745100774 scopus 로고    scopus 로고
    • Numerical characterization of the flow rectification of dynamic microdiffusers
    • DOI 10.1088/0960-1317/16/7/030, PII S096013170614231X, 030
    • C Sun K Huang 2006 Numerical characterization of the flow rectification of dynamic microdiffusers J Micromech Microeng 16 1331 1339 10.1088/0960-1317/ 16/7/030 (Pubitemid 43884513)
    • (2006) Journal of Micromechanics and Microengineering , vol.16 , Issue.7 , pp. 1331-1339
    • Sun, C.-L.1    Huang, K.H.2
  • 49
    • 46149105693 scopus 로고    scopus 로고
    • A novel fabrication approach for microneedles using silicon micromachining technology
    • Wang X, et al. A novel fabrication approach for microneedles using silicon micromachining technology. In: 1st IEEE international conference on NEMS. 2006. p. 545-49.
    • (2006) 1st IEEE International Conference on NEMS , pp. 545-549
    • Wang, X.1
  • 50
    • 33947713082 scopus 로고    scopus 로고
    • Unsteady analysis of microvalves with no moving parts
    • C Wang T Leu J Sun 2007 Unsteady analysis of microvalves with no moving parts J Mech 23 9 14
    • (2007) J Mech , vol.23 , pp. 9-14
    • Wang, C.1    Leu, T.2    Sun, J.3
  • 51
    • 24944508964 scopus 로고    scopus 로고
    • Silicon microneedle electrode array with temperature monitoring for electroporation
    • N Wilke, et al. 2005 Silicon microneedle electrode array with temperature monitoring for electroporation Sens Actuators A 1090 123-124 319 325
    • (2005) Sens Actuators A , vol.1090 , Issue.123-124 , pp. 319-325
    • Wilke, N.1
  • 52
    • 22144493011 scopus 로고    scopus 로고
    • Process optimization and characterization of silicon microneedles fabricated by wet etch technology
    • 1:CAS:528:DC%2BD2MXmtFGgurc%3D
    • N Wilke, et al. 2005 Process optimization and characterization of silicon microneedles fabricated by wet etch technology Micro Electron J 36 650 656 1:CAS:528:DC%2BD2MXmtFGgurc%3D
    • (2005) Micro Electron J , vol.36 , pp. 650-656
    • Wilke, N.1
  • 53
    • 0033617085 scopus 로고    scopus 로고
    • Numerical investigation of a laminar pulsating flow in a rectangular duct
    • DOI 10.1002/(SICI)1097-0363(19990430)29:8<935::AID-FLD823>3.0.CO;2- C
    • A Yakhot M Arad G Ben-Dor 1999 Numerical investigation of a laminar pulsating flow in a rectangular duct Int J Numer Methods Fluids 29 935 950 10.1002/(SICI)1097-0363(19990430)29:8<935::AID-FLD823>3.0.CO;2-C (Pubitemid 29360799)
    • (1999) International Journal for Numerical Methods in Fluids , vol.29 , Issue.8 , pp. 935-950
    • Yakhot, A.1    Arad, M.2    Ben-Dor, G.3
  • 55
    • 0008670190 scopus 로고    scopus 로고
    • Micro fabricated polysilicon microneedles for minimally invasive biomedical devices
    • 10.1023/A:1009907306184
    • JD Zahn, et al. 2000 Micro fabricated polysilicon microneedles for minimally invasive biomedical devices Biomed Microdevices 2 295 303 10.1023/A:1009907306184
    • (2000) Biomed Microdevices , vol.2 , pp. 295-303
    • Zahn, J.D.1
  • 56
    • 4544350495 scopus 로고    scopus 로고
    • Continuous on-chip micropumping for microneedle enhanced drug delivery
    • DOI 10.1023/B:BMMD.0000042047.83433.96
    • JD Zahn, et al. 2004 Continuous on-chip micropumping for microneedle enhanced drug delivery Biomed Microdevices 6 3 183 190 1:CAS:528: DC%2BD2cXns1ert7w%3D 10.1023/B:BMMD.0000042047.83433.96 15377827 (Pubitemid 39256164)
    • (2004) Biomedical Microdevices , vol.6 , Issue.3 , pp. 183-190
    • Zahn, J.D.1    Deshmukh, A.2    Pisano, A.P.3    Liepmann, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.