메뉴 건너뛰기




Volumn 6, Issue 4, 1997, Pages 337-346

Microfabricated lamb wave device based on PZT sol-gel thin film for mechanical transport of solid particles and liquids

(7)  Luginbuhl, Philippe a,d   Collins, Scott D a,b,d,e,f,g,h,i,j   Racine, Georges André a,d   Grétillat, Marc Alexis a,d   De Rooij, Nicolaas F a,c,k,l,m,n   Brooks, Keith G c,o,p   Setter, Nava c,p,q,r,s,t,u  


Author keywords

Flexural plate waves; Lamb wave acoustic transducers; Micropump; Microtransport; PZT sol gel thin film

Indexed keywords

ACOUSTIC TRANSDUCERS; FABRICATION; LIQUIDS; MICROMACHINING; PIEZOELECTRIC MATERIALS; PIEZOELECTRIC TRANSDUCERS; SENSORS; SILICON NITRIDE; SOL-GELS; THIN FILMS;

EID: 0031354318     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/84.650131     Document Type: Article
Times cited : (88)

References (35)
  • 1
    • 0027703107 scopus 로고
    • Acoustic wave microsensors
    • J. W. Grate, S. J. Martin, and R. M. White, "Acoustic wave microsensors," Anal. Chem., vol. 65, pp. 940A-958A and 987A-996A, 1993.
    • (1993) Anal. Chem. , vol.65
    • Grate, J.W.1    Martin, S.J.2    White, R.M.3
  • 2
    • 33845559687 scopus 로고
    • Surface acoustic wave probe for chemical analysis
    • H. Wohltjen and R. Dessy, "Surface acoustic wave probe for chemical analysis," Anal. Chem., vol. 51, pp. 1458-1475, 1979.
    • (1979) Anal. Chem. , vol.51 , pp. 1458-1475
    • Wohltjen, H.1    Dessy, R.2
  • 3
    • 0017556722 scopus 로고
    • Applications of the piezoelectric crystal detector in analytical chemistry
    • J. Hlavay and G. G. Guilbault, "Applications of the piezoelectric crystal detector in analytical chemistry," Anal. Chem., vol. 49, pp. 1890-1898, 1977.
    • (1977) Anal. Chem. , vol.49 , pp. 1890-1898
    • Hlavay, J.1    Guilbault, G.G.2
  • 4
    • 0028497346 scopus 로고
    • Flow sensors based on surface acoustic waves
    • F. G. Joshi, "Flow sensors based on surface acoustic waves," Sens. Actuators, vol. A-44, pp. 191-197, 1994.
    • (1994) Sens. Actuators , vol.A-44 , pp. 191-197
    • Joshi, F.G.1
  • 5
    • 0024897159 scopus 로고
    • Characterization of SH acoustic plate mode liquid sensors
    • S. J. Martin, A. J. Ricco, T. M. Niemczyk, and G. C. Frye, "Characterization of SH acoustic plate mode liquid sensors," Sens. Actuators, vol. 20, pp. 253-268, 1989.
    • (1989) Sens. Actuators , vol.20 , pp. 253-268
    • Martin, S.J.1    Ricco, A.J.2    Niemczyk, T.M.3    Frye, G.C.4
  • 7
    • 0343978078 scopus 로고
    • Generation and detection of ultrasonic Lamb waves in a thin deposited film by using interdigital transducers
    • K. Uozumi, K. Ohsone, and R. M. White, "Generation and detection of ultrasonic Lamb waves in a thin deposited film by using interdigital transducers," Appl. Phys. Lett., vol. 43, no. 10, pp. 917-919, 1983.
    • (1983) Appl. Phys. Lett. , vol.43 , Issue.10 , pp. 917-919
    • Uozumi, K.1    Ohsone, K.2    White, R.M.3
  • 9
    • 0344747568 scopus 로고
    • An ultrasonic flexuralplate-wave sensor for measurement of diffusion in gels
    • A. W. Wang, B. J. Costello, and R. M. White, "An ultrasonic flexuralplate-wave sensor for measurement of diffusion in gels," Anal. Chem., vol. 65, pp. 1639-1642, 1993.
    • (1993) Anal. Chem. , vol.65 , pp. 1639-1642
    • Wang, A.W.1    Costello, B.J.2    White, R.M.3
  • 10
    • 0028430348 scopus 로고
    • Evaluation of liquid properties using a silicon Lamb wave sensor
    • M. J. Vellekoop, G. W. Lubking, P. M. Sarro, and A. Venema, "Evaluation of liquid properties using a silicon Lamb wave sensor," Sens. Actuators, vol. A, no. 43, pp. 175-180, 1994.
    • (1994) Sens. Actuators , vol.A , Issue.43 , pp. 175-180
    • Vellekoop, M.J.1    Lubking, G.W.2    Sarro, P.M.3    Venema, A.4
  • 11
    • 0000919566 scopus 로고
    • Ultrasonically induced microtransport
    • R. M. Moroney, R. M. White, and R. T. Howe, "Ultrasonically induced microtransport," Appl. Phys. Lett., vol. 59, pp. 774-776, 1991.
    • (1991) Appl. Phys. Lett. , vol.59 , pp. 774-776
    • Moroney, R.M.1    White, R.M.2    Howe, R.T.3
  • 12
    • 0028742106 scopus 로고
    • Flexural-plate waves for sensors and micropumps
    • Dec.
    • S. W. Wenzel, B. J. Costello, and R. M. White, "Flexural-plate waves for sensors and micropumps," Sensors Mag., vol. 11, pp. 47-49, Dec. 1994.
    • (1994) Sensors Mag. , vol.11 , pp. 47-49
    • Wenzel, S.W.1    Costello, B.J.2    White, R.M.3
  • 13
    • 0043058551 scopus 로고
    • Silicon-based ultrasonic microsensors and micropumps
    • R. M. White, "Silicon-based ultrasonic microsensors and micropumps," Integrated Ferroelectrics, vol. 7, pp. 353-358, 1995.
    • (1995) Integrated Ferroelectrics , vol.7 , pp. 353-358
    • White, R.M.1
  • 17
    • 36549104035 scopus 로고
    • 3 thin films deposited from multi-element metal targets
    • 3 thin films deposited from multi-element metal targets," J. Appl. Phys., vol. 64, no. 3, pp. 1484-1493, 1988.
    • (1988) J. Appl. Phys. , vol.64 , Issue.3 , pp. 1484-1493
    • Sreenivas, K.1    Sayer, M.2
  • 22
    • 0029536533 scopus 로고
    • Microelectromechanical systems based on ferroelectric thin films
    • D. L. Polla, "Microelectromechanical systems based on ferroelectric thin films," Microelectron. Eng., vol. 29, pp. 51-58, 1995.
    • (1995) Microelectron. Eng. , vol.29 , pp. 51-58
    • Polla, D.L.1
  • 27
    • 0003048396 scopus 로고
    • 3 thin films by in-situ reactive sputtering on micromachined membranes for micromechanical applications
    • 3 thin films by in-situ reactive sputtering on micromachined membranes for micromechanical applications," in Bri. Ceramics Proc., vol. 54, 1995, pp. 206-213.
    • (1995) Bri. Ceramics Proc. , vol.54 , pp. 206-213
    • Maeder, T.1    Muralt, P.2    Kohli, M.3    Kholkin, A.4    Setter, N.5
  • 29
    • 0040284325 scopus 로고
    • New York: Wiley, ch. 3
    • S. M. Sze, Semiconductor Sensors. New York: Wiley, 1994, ch. 3, pp. 97-151.
    • (1994) Semiconductor Sensors , pp. 97-151
    • Sze, S.M.1
  • 30
    • 0024941006 scopus 로고
    • Ultrasonic plate wave for biochemical measurements
    • Montreal, Canada, Oct.
    • B. J. Costello, B. A. Martin, and R. M. White, "Ultrasonic plate wave for biochemical measurements," in Proc. IEEE Ultrasonics Symp., Montreal, Canada, Oct. 1989, pp. 977-981.
    • (1989) Proc. IEEE Ultrasonics Symp. , pp. 977-981
    • Costello, B.J.1    Martin, B.A.2    White, R.M.3
  • 31
    • 0024034427 scopus 로고
    • A multisensor employing an ultrasonic Lamb-wave oscillator
    • S. W. Wenzel and R. M. White, "A multisensor employing an ultrasonic Lamb-wave oscillator," IEEE Trans. Electron Devices, vol. 35, no. 6, pp. 735-743, 1988.
    • (1988) IEEE Trans. Electron Devices , vol.35 , Issue.6 , pp. 735-743
    • Wenzel, S.W.1    White, R.M.2
  • 33
    • 0030193126 scopus 로고    scopus 로고
    • Degradation mechanisms in ferroelectric and high-permittivity perovskites
    • July
    • W. L. Warren, D. Dimos, and R. M. Waser, "Degradation mechanisms in ferroelectric and high-permittivity perovskites," MRS (Material Research Soc.) Bull., vol. 21, no. 7, pp. 40-45, July 1996.
    • (1996) MRS (Material Research Soc.) Bull. , vol.21 , Issue.7 , pp. 40-45
    • Warren, W.L.1    Dimos, D.2    Waser, R.M.3
  • 34
    • 0038410769 scopus 로고
    • Effect of top metallization on the fatigue and retention properties of sol-gel PZT thin films
    • G. Teowee, C. D. Baertlein, E. A. Kneer, J. M. Boulton, and D. R. Uhlmann, "Effect of top metallization on the fatigue and retention properties of sol-gel PZT thin films," Integrated Ferroelectrics, vol. 7, pp. 149-160, 1995.
    • (1995) Integrated Ferroelectrics , vol.7 , pp. 149-160
    • Teowee, G.1    Baertlein, C.D.2    Kneer, E.A.3    Boulton, J.M.4    Uhlmann, D.R.5
  • 35
    • 0028741156 scopus 로고
    • Acoustically driven flow in flexural plate wave devices: Theory and experiment
    • C. E. Bradley and R. M. White, "Acoustically driven flow in flexural plate wave devices: Theory and experiment," in Proc. IEEE Ultrasonics Symp., 1994, pp. 593-597.
    • (1994) Proc. IEEE Ultrasonics Symp. , pp. 593-597
    • Bradley, C.E.1    White, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.