메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1306-1309

A novel mask-less method of fabricating high aspect ratio microneedles for blood sampling

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD SAMPLING; MICRO-NEEDLES;

EID: 51349149670     PISSN: 05695503     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ECTC.2008.4550144     Document Type: Conference Paper
Times cited : (12)

References (13)
  • 3
    • 0030314258 scopus 로고    scopus 로고
    • H. M. Heise, Technology for non-invasive monitoring of glucose, In: Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Part 5 (of 5), Oct 31-Nov 3, Amsterdam, Netherlands, 1996.
    • H. M. Heise, "Technology for non-invasive monitoring of glucose," In: Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Part 5 (of 5), Oct 31-Nov 3, Amsterdam, Netherlands, 1996.
  • 4
    • 51349161784 scopus 로고    scopus 로고
    • http://www.hamiltoncomp.com/newdev/syringes/
  • 6
    • 84885514736 scopus 로고    scopus 로고
    • S. M. Chandrasekaran, S.K.; Frazier, A.B., Autonomous microneedle system for biochemical analysis, presented at TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th Innational Conference on, 2003, 2003.
    • S. M. Chandrasekaran, S.K.; Frazier, A.B., "Autonomous microneedle system for biochemical analysis," presented at TRANSDUCERS, Solid-State Sensors, Actuators and Microsystems, 12th Innational Conference on, 2003, 2003.
  • 11
    • 0037871729 scopus 로고    scopus 로고
    • Side-Opened Out-of-Plane Microneedles for Microfluidic Transdermal Liquid Transfer
    • P. Griss and G. Stemme, "Side-Opened Out-of-Plane Microneedles for Microfluidic Transdermal Liquid Transfer," Journal of MicroelectromechanicalSystems, vol. 12, pp. 296-301, 2003.
    • (2003) Journal of MicroelectromechanicalSystems , vol.12 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 12
    • 0026205082 scopus 로고
    • A Silicon-Based, Three Dimensional Neural Interface: Manufacturing Processes for an Intra cortical Electrode Array
    • August
    • P. K. Campbell, K. E. Jones, R. J. Huber, K. W. Horch, R. A. Normann, "A Silicon-Based, Three Dimensional Neural Interface: Manufacturing Processes for an Intra cortical Electrode Array", IEEE Transaction on Biomedical Engineering, Vol. 38, No. 38, August 1991, 758-768.
    • (1991) IEEE Transaction on Biomedical Engineering , vol.38 , Issue.38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.