메뉴 건너뛰기




Volumn 15, Issue 7, 2009, Pages 1073-1082

Design and fabrication of MEMS-based microneedle arrays for medical applications

Author keywords

[No Author keywords available]

Indexed keywords

BLIND HOLES; CYLINDRICAL BODIES; ETCH STOP; FLUID FLOW; MICRONEEDLE ARRAYS; NEEDLE LENGTH; SHARP TIP;

EID: 67650417889     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-009-0883-5     Document Type: Article
Times cited : (57)

References (49)
  • 2
    • 3042822474 scopus 로고    scopus 로고
    • Microfabricated silicon microneedles for nonviral cutaneous gene delivery
    • 10.1111/j.1365-2133.2004.05921.x
    • F Chabri K Bouris T Jones 2004 Microfabricated silicon microneedles for nonviral cutaneous gene delivery Br J Dermatol 150 869 877 10.1111/j.1365-2133. 2004.05921.x
    • (2004) Br J Dermatol , vol.150 , pp. 869-877
    • Chabri, F.1    Bouris, K.2    Jones, T.3
  • 4
    • 0037699910 scopus 로고    scopus 로고
    • Surface micromachined metallic microneedles
    • 10.1109/JMEMS.2003.809951
    • S Chandrasekaran JD Brazzle AB Frazier 2003 Surface micromachined metallic microneedles J Microelectromech Syst 12 3 281 288 10.1109/JMEMS.2003. 809951
    • (2003) J Microelectromech Syst , vol.12 , Issue.3 , pp. 281-288
    • Chandrasekaran, S.1    Brazzle, J.D.2    Frazier, A.B.3
  • 5
    • 0040451916 scopus 로고
    • A multichannel neural probe for selective chemical delivery at the cellular level
    • Hilton Head, SC
    • Chen J, Wise KD (1994) A multichannel neural probe for selective chemical delivery at the cellular level. Solid state sensor and actuator workshop, Hilton Head, SC., pp 256-259
    • (1994) Solid State Sensor and Actuator Workshop , pp. 256-259
    • Chen, J.1    Wise, K.D.2
  • 6
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force
    • 10.1016/j.jbiomech.2003.12.010
    • SP Davis BJ Landis ZH Adams MG Allen MR Prausnitz 2004 Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force J Biomech 37 8 1155 1163 10.1016/j.jbiomech.2003.12.010
    • (2004) J Biomech , vol.37 , Issue.8 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 9
    • 0742301752 scopus 로고    scopus 로고
    • A silicon micromachined hollow microneedles for transdermal liquid transport
    • 10.1109/JMEMS.2003.820293
    • HJGE Gardeniers R Luttge EJW Berenschot 2003 A silicon micromachined hollow microneedles for transdermal liquid transport J Microelectromech Syst 12 6 855 862 10.1109/JMEMS.2003.820293
    • (2003) J Microelectromech Syst , vol.12 , Issue.6 , pp. 855-862
    • Gardeniers, H.J.G.E.1    Luttge, R.2    Berenschot, E.J.W.3
  • 11
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • 10.1109/JMEMS.2003.809959
    • P Griss G Stemme 2003 Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer J Microelectromech Syst 12 3 296 301 10.1109/JMEMS.2003.809959
    • (2003) J Microelectromech Syst , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 12
    • 0029085936 scopus 로고
    • Needle phobia: a neglected diagnosis
    • J Hamilton 1995 Needle phobia: a neglected diagnosis J Fam Pract 41 169 175
    • (1995) J Fam Pract , vol.41 , pp. 169-175
    • Hamilton, J.1
  • 14
    • 2342632586 scopus 로고    scopus 로고
    • A tapered hollow metallic microneedle array using backside exposure of SU-8
    • 10.1088/0960-1317/14/4/021
    • K Kabseog SP Daniel ML Hong 2004 A tapered hollow metallic microneedle array using backside exposure of SU-8 J Micromech Microeng 14 597 603 10.1088/0960-1317/14/4/021
    • (2004) J Micromech Microeng , vol.14 , pp. 597-603
    • Kabseog, K.1    Daniel, S.P.2    Hong, M.L.3
  • 17
    • 21644444347 scopus 로고    scopus 로고
    • Novel-shaped microneedle arrays for multiple uses of Bio-medical applications
    • F2.6, 2004 7th International Conference on Solid-State and Integrated Circuits Technology Proceedings, ICSICT 2004
    • Khumpuang S, Susumu S (2004) Novel-shaped microneedle arrays for multiple uses of bio-medical applications, vol 3. In: Proceedings of 7th international conference on solid-state and integrated circuit's technology, pp 1780-1783 (Pubitemid 40931363)
    • (2004) International Conference on Solid-State and Integrated Circuits Technology Proceedings, ICSICT , vol.3 , pp. 1780-1783
    • Khumpuang, S.1    Susumu, S.2
  • 18
    • 67650401266 scopus 로고    scopus 로고
    • Using a study of skin to teach stress and strain in high school physics, anatomy and physiology, and engineering
    • Klein SS (2006) Using a study of skin to teach stress and strain in high school physics, anatomy and physiology, and engineering. In: Proceedings of the 9th international conference on engineering education
    • (2006) Proceedings of the 9th International Conference on Engineering Education
    • Klein, S.S.1
  • 19
    • 2942722611 scopus 로고    scopus 로고
    • A novel polymer microneedle arrays and PDMS micromolding technique
    • Kuo SC, Chou (2004) A novel polymer microneedle arrays and PDMS micromolding technique. Tamkang J Sci Eng 7(2):95-98
    • (2004) Tamkang J Sci Eng , vol.7 , Issue.2 , pp. 95-98
    • Kuo, S.C.1
  • 20
    • 0032580354 scopus 로고    scopus 로고
    • Drug delivery and targeting
    • Langer R (1998) Drug delivery and targeting. Nature 392(6679)(Suppl):5-10 (Pubitemid 28215187)
    • (1998) Nature , vol.392 , Issue.SUPPL. , pp. 5-10
    • Langer, R.1
  • 23
    • 32244440926 scopus 로고    scopus 로고
    • Microinfusion using hollow microneedles
    • 10.1007/s11095-005-8498-8
    • W Martanto JS Moore O Kashlan 2006 Microinfusion using hollow microneedles Pharm Res 23 1 104 113 10.1007/s11095-005-8498-8
    • (2006) Pharm Res , vol.23 , Issue.1 , pp. 104-113
    • Martanto, W.1    Moore, J.S.2    Kashlan, O.3
  • 24
    • 0034578084 scopus 로고    scopus 로고
    • Microfabricated microneedles for gene and drug delivery
    • 10.1146/annurev.bioeng.2.1.289
    • DV McAllister MG Allen MR Prausnitz 2000 Microfabricated microneedles for gene and drug delivery Annu Rev Biomed Eng 2 289 313 10.1146/annurev.bioeng.2. 1.289
    • (2000) Annu Rev Biomed Eng , vol.2 , pp. 289-313
    • McAllister, D.V.1    Allen, M.G.2    Prausnitz, M.R.3
  • 25
    • 0344270926 scopus 로고    scopus 로고
    • Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: fabrication methods and transport studies
    • 10.1073/pnas.2331316100
    • DV McAllister PM Wang SP Davis 2003 Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: fabrication methods and transport studies Proc Natl Acad Sci USA 100 24 13755 13760 10.1073/pnas.2331316100
    • (2003) Proc Natl Acad Sci USA , vol.100 , Issue.24 , pp. 13755-13760
    • McAllister, D.V.1    Wang, P.M.2    Davis, S.P.3
  • 26
    • 0036105150 scopus 로고    scopus 로고
    • Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery
    • 10.1038/nm0402-415
    • JA Mikszta JB Alarcon JM Brittingham 2002 Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery Nat Med 8 415 419 10.1038/nm0402-415
    • (2002) Nat Med , vol.8 , pp. 415-419
    • Mikszta, J.A.1    Alarcon, J.B.2    Brittingham, J.M.3
  • 27
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • 10.1016/j.sna.2003.11.008
    • EV Mukerjee SD Collins RR Isseroff RL Smith 2004 Microneedle array for transdermal biological fluid extraction and in situ analysis Sensors Actuators A Phys 114 267 275 10.1016/j.sna.2003.11.008
    • (2004) Sensors Actuators A Phys , vol.114 , pp. 267-275
    • Mukerjee, E.V.1    Collins, S.D.2    Isseroff, R.R.3    Smith, R.L.4
  • 28
    • 0022863439 scopus 로고
    • IMPLANTABLE MULTIELECTRODE ARRAY WITH ON-CHIP SIGNAL PROCESSING.
    • K Najafi K Wise 1986 An implantable multielectrode array with on-chip signal processing IEEE J Solid-State Circuits SC-21 1035 1044 10.1109/JSSC.1986.1052646 (Pubitemid 17500540)
    • (1986) IEEE Journal of Solid-State Circuits , vol.SC-21 , Issue.6 , pp. 1035-1044
    • Najafi Khalil1    Wise Kensall, D.2
  • 30
    • 33645213642 scopus 로고    scopus 로고
    • Fabrication and characterization of microfluidic probes
    • 10.1016/j.jconrel.2005.11.018
    • KB Neeves CT Lo 2006 Fabrication and characterization of microfluidic probes J Control Release 111 252 262 10.1016/j.jconrel.2005.11.018
    • (2006) J Control Release , vol.111 , pp. 252-262
    • Neeves, K.B.1    Lo, C.T.2
  • 31
    • 33744461297 scopus 로고    scopus 로고
    • A review of microvalves
    • 10.1088/0960-1317/16/5/R01
    • KW Oh CH Ahn 2006 A review of microvalves J Micromech Microeng 16 5 R13 R39 10.1088/0960-1317/16/5/R01
    • (2006) J Micromech Microeng , vol.16 , Issue.5
    • Oh, K.W.1    Ahn, C.H.2
  • 33
    • 1542358759 scopus 로고    scopus 로고
    • Microneedles for transdermal drug delivery
    • 10.1016/j.addr.2003.10.023
    • MR Prausnitz 2004 Microneedles for transdermal drug delivery Adv Drug Deliv Rev 56 581 587 10.1016/j.addr.2003.10.023
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 581-587
    • Prausnitz, M.R.1
  • 35
    • 18144397536 scopus 로고    scopus 로고
    • Microsystems for drug and gene delivery
    • 10.1109/JPROC.2003.820542
    • ML Reed WK Lye 2004 Microsystems for drug and gene delivery Proc IEEE 92 1 56 75 10.1109/JPROC.2003.820542
    • (2004) Proc IEEE , vol.92 , Issue.1 , pp. 56-75
    • Reed, M.L.1    Lye, W.K.2
  • 36
    • 33847301400 scopus 로고    scopus 로고
    • Polymeric microneedle fabrication using a microinjection molding technique
    • 10.1007/s00542-006-0204-1
    • F Sammoura J Kang YM Heo TS Jung L Lin 2007 Polymeric microneedle fabrication using a microinjection molding technique Microsyst Technol 13 517 522 10.1007/s00542-006-0204-1
    • (2007) Microsyst Technol , vol.13 , pp. 517-522
    • Sammoura, F.1    Kang, J.2    Heo, Y.M.3    Jung, T.S.4    Lin, L.5
  • 37
    • 14844345011 scopus 로고    scopus 로고
    • Noninvasive and minimally invasive methods for transdermal glucose monitoring
    • 10.1089/dia.2005.7.174
    • A Sieg RH Guy MB Delgado-Charro 2005 Noninvasive and minimally invasive methods for transdermal glucose monitoring Diabetes Technol Ther 7 1 174 197 10.1089/dia.2005.7.174
    • (2005) Diabetes Technol Ther , vol.7 , Issue.1 , pp. 174-197
    • Sieg, A.1    Guy, R.H.2    Delgado-Charro, M.B.3
  • 38
    • 17444403584 scopus 로고    scopus 로고
    • Clinical microneedle injection of methyl nicotinate: stratum corneum penetration
    • 10.1111/j.1600-0846.2005.00107.x
    • RK Sivamani B Stoeber CC Wu 2005 Clinical microneedle injection of methyl nicotinate: stratum corneum penetration Skin Res Technol 11 152 156 10.1111/j.1600-0846.2005.00107.x
    • (2005) Skin Res Technol , vol.11 , pp. 152-156
    • Sivamani, R.K.1    Stoeber, B.2    Wu, C.C.3
  • 39
    • 0034467470 scopus 로고    scopus 로고
    • The use of silicon microfabrication technology in painless blood glucose monitoring
    • 10.1089/15209150050501961
    • WH Smart K Subramanian 2000 The use of silicon microfabrication technology in painless blood glucose monitoring Diabetes Technol Ther 2 4 549 559 10.1089/15209150050501961
    • (2000) Diabetes Technol Ther , vol.2 , Issue.4 , pp. 549-559
    • Smart, W.H.1    Subramanian, K.2
  • 42
    • 0040451922 scopus 로고    scopus 로고
    • Hypodermic injection. The world book encyclopedia
    • The World Book Encyclopedia
    • The World Book Encyclopedia 1999 Hypodermic injection. The world book encyclopedia World Book Chic 9 480 481
    • (1999) World Book Chic , vol.9 , pp. 480-481
  • 44
    • 33646148967 scopus 로고    scopus 로고
    • Precise microinjection into skin using hollow microneedles
    • 10.1038/sj.jid.5700150
    • PM Wang M Cornwell 2006 Precise microinjection into skin using hollow microneedles J Invest Dermatol 126 1080 1087 10.1038/sj.jid.5700150
    • (2006) J Invest Dermatol , vol.126 , pp. 1080-1087
    • Wang, P.M.1    Cornwell, M.2
  • 48
    • 0011884070 scopus 로고    scopus 로고
    • Bulk silicon holding structures of fibers for the micromachined optical devices
    • Hong Kong
    • Zhang P, Wu G, et al. (2000) Bulk silicon holding structures of fibers for the micromachined optical devices. In: International symposium smart structures and microsystems, Hong Kong, B3-B4
    • (2000) International Symposium Smart Structures and Microsystems
    • Zhang P1    Wu G2
  • 49
    • 74349087776 scopus 로고    scopus 로고
    • Modeling of drug delivery into tissues with a microneedle array using mixture theory
    • in press
    • Zhang R, Zhang P, Dalton C, Jullien GA (2009) Modeling of drug delivery into tissues with a microneedle array using mixture theory. Biomech Model Mechanobiol (in press)
    • (2009) Biomech Model Mechanobiol
    • Zhang, R.1    Zhang, P.2    Dalton, C.3    Jullien, G.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.