메뉴 건너뛰기




Volumn 32, Issue 1, 2004, Pages 171-177

Bioabsorbable implants: Review of clinical experience in orthopedic surgery

Author keywords

Biodegradable; Bioresorbable; Polyglycolic acid; Polyglyconate; Polylactic acid

Indexed keywords

BIORESORBABLE; POLYACTIC ACID; POLYGLYCOLIC ACID; POLYGLYCONATE;

EID: 2942592481     PISSN: 00906964     EISSN: None     Source Type: Journal    
DOI: 10.1023/B:ABME.0000007802.59936.fc     Document Type: Review
Times cited : (180)

References (59)
  • 1
    • 0031172250 scopus 로고    scopus 로고
    • Technique to control pH in the vicinity of biodegrading PLA-PGA implants
    • Agrawal, C. M., and K. A. Athanasiou. Technique to control pH in the vicinity of biodegrading PLA-PGA implants. J. Biomed. Mater. Res. 38:105-114, 1997.
    • (1997) J. Biomed. Mater. Res. , vol.38 , pp. 105-114
    • Agrawal, C.M.1    Athanasiou, K.A.2
  • 2
    • 0036828516 scopus 로고    scopus 로고
    • Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up
    • Bach, F. D., R. Y. Carlier, J. B. Elis, D. M. Mompoint, A. Feyday, O. Judet, P. Beaufils, and C. Vallee. Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up. Radiology 225:541-550, 2002.
    • (2002) Radiology , vol.225 , pp. 541-550
    • Bach, F.D.1    Carlier, R.Y.2    Elis, J.B.3    Mompoint, D.M.4    Feyday, A.5    Judet, O.6    Beaufils, P.7    Vallee, C.8
  • 3
    • 0032962290 scopus 로고    scopus 로고
    • Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation
    • Barber, F. A. Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation. Arthroscopy 15:360-367, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 360-367
    • Barber, F.A.1
  • 4
    • 2942529922 scopus 로고    scopus 로고
    • Resorbable materials for arthroscopic fixation: A product guide
    • Barber, F. A. Resorbable materials for arthroscopic fixation: A product guide. Orthopedic Spec. Ed. 8:29-37, 2002.
    • (2002) Orthopedic Spec. Ed. , vol.8 , pp. 29-37
    • Barber, F.A.1
  • 5
    • 0028786512 scopus 로고
    • Preliminary results of an absorbable interference screw
    • Barber, F. A., B. F. Elrod, D. A. McGuire, and L. E. Paulos. Preliminary results of an absorbable interference screw. Arthroscopy 11:537-548, 1995.
    • (1995) Arthroscopy , vol.11 , pp. 537-548
    • Barber, F.A.1    Elrod, B.F.2    McGuire, D.A.3    Paulos, L.E.4
  • 7
    • 0033985852 scopus 로고    scopus 로고
    • A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial
    • Benedetto, K. P., M. Fellinger, T. E. Lim, J. M. Passler, J. L. Schoen, and W. J. Willems. A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41-48, 2000.
    • (2000) Arthroscopy , vol.16 , pp. 41-48
    • Benedetto, K.P.1    Fellinger, M.2    Lim, T.E.3    Passler, J.M.4    Schoen, J.L.5    Willems, W.J.6
  • 8
    • 0028878553 scopus 로고
    • Late degradation tissue response to poly(l-lactide) bone plates and screws
    • Bergsma, J. E., W. C. de Bruijn, F. R. Rozema, R. R. M. Bos, and G. Boering. Late degradation tissue response to poly(l-lactide) bone plates and screws. Biomaterials 16:25-31, 1995.
    • (1995) Biomaterials , vol.16 , pp. 25-31
    • Bergsma, J.E.1    De Bruijn, W.C.2    Rozema, F.R.3    Bos, R.R.M.4    Boering, G.5
  • 9
    • 0030954702 scopus 로고    scopus 로고
    • A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery
    • Bessho, K., T. Iiluka, and K.-I. Murakami. A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery. J. Oral Maxillofac. Surg. 55:941-945, 1997.
    • (1997) J. Oral Maxillofac. Surg. , vol.55 , pp. 941-945
    • Bessho, K.1    Iiluka, T.2    Murakami, K.-I.3
  • 10
    • 0029809720 scopus 로고    scopus 로고
    • Metallic or absorbable fracture fixation devices: A cost minimization analysis
    • Bostman, O. M. Metallic or absorbable fracture fixation devices: A cost minimization analysis. Clin. Orthop. 329:233-239, 1996.
    • (1996) Clin. Orthop. , vol.329 , pp. 233-239
    • Bostman, O.M.1
  • 12
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reactions to bioabsorbable fixation devices
    • Bostman, O. M., and H. K. Pihlajamaki. Adverse tissue reactions to bioabsorbable fixation devices. Clin. Orthop. 216-227, 2000.
    • (2000) Clin. Orthop. , vol.216 , Issue.227
    • Bostman, O.M.1    Pihlajamaki, H.K.2
  • 13
    • 0034068873 scopus 로고    scopus 로고
    • An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction
    • Bottoni, C. R., T. M. DeBerardina, E. W. Fester, D. Mitchell, and B. J. Penrod. An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 16:395-398, 2000.
    • (2000) Arthroscopy , vol.16 , pp. 395-398
    • Bottoni, C.R.1    Deberardina, T.M.2    Fester, E.W.3    Mitchell, D.4    Penrod, B.J.5
  • 14
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Bucholz, R. W., S. Henry, and M. B. Henley. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J. Bone Joint Surg. Am. 76:319-324, 1994.
    • (1994) J. Bone Joint Surg. Am. , vol.76 , pp. 319-324
    • Bucholz, R.W.1    Henry, S.2    Henley, M.B.3
  • 15
    • 0033985333 scopus 로고    scopus 로고
    • Foreign-body reaction to the bioabsorbable suretac device
    • Burkart, A., A. B. Imhoff, and E. Roscher. Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy 16:91-95, 2000.
    • (2000) Arthroscopy , vol.16 , pp. 91-95
    • Burkart, A.1    Imhoff, A.B.2    Roscher, E.3
  • 16
    • 0026473093 scopus 로고
    • Biodegradable rods versus kirschner wire fixation of wrist fractures: A randomised trial
    • Casteleyn, P. P., F. Handelberg, and P. Haentjens. Biodegradable rods versus kirschner wire fixation of wrist fractures: A randomised trial. J. Bone Joint Surg. Br. 74:858-861, 1992.
    • (1992) J. Bone Joint Surg. Br. , vol.74 , pp. 858-861
    • Casteleyn, P.P.1    Handelberg, F.2    Haentjens, P.3
  • 18
    • 0015076420 scopus 로고
    • Fracture reduction using a biodegradable material, polylactic acid
    • Cutright, D. E., E. E. Hunsuck, and J. D. Beasley. Fracture reduction using a biodegradable material, polylactic acid. J. Oral Surg. 29:393-397, 1971.
    • (1971) J. Oral Surg. , vol.29 , pp. 393-397
    • Cutright, D.E.1    Hunsuck, E.E.2    Beasley, J.D.3
  • 20
    • 0036716221 scopus 로고    scopus 로고
    • Clinical evaluation of meniscus repair with a bioabsorbable arrow: A 2-to 3-year followup study
    • Ellerman, A., R. Siebold, J. U. Buelow, and C. Sobau. Clinical evaluation of meniscus repair with a bioabsorbable arrow: A 2-to 3-year followup study. Knee. Surg. Sports Traumatol. Arthrosc. 10:289-293, 2002.
    • (2002) Knee. Surg. Sports Traumatol. Arthrosc. , vol.10 , pp. 289-293
    • Ellerman, A.1    Siebold, R.2    Buelow, J.U.3    Sobau, C.4
  • 21
    • 0024835916 scopus 로고
    • Fracture fixation with biodegradable rods: Forty-one cases of sever ankle fractures
    • Hirvensalo, E. Fracture fixation with biodegradable rods: Forty-one cases of sever ankle fractures. Acta Orthop. Scand. 60:601-606, 1989.
    • (1989) Acta Orthop. Scand. , vol.60 , pp. 601-606
    • Hirvensalo, E.1
  • 22
    • 0028918524 scopus 로고
    • Biodegradable implants in traumatology: A review on the state-of-the-art
    • Hofmann, G. O. Biodegradable implants in traumatology: A review on the state-of-the-art. Arch. Orthop. Trauma Surg. 114:123-132, 1995.
    • (1995) Arch. Orthop. Trauma Surg. , vol.114 , pp. 123-132
    • Hofmann, G.O.1
  • 23
    • 0030939672 scopus 로고    scopus 로고
    • Polyglycolide bioabsorbable screws in the treatment of ankle fractures
    • Hovis, W. D., and R. W. Bucholz, Polyglycolide bioabsorbable screws in the treatment of ankle fractures. Foot Ankle Int. 18:128-131, 1997.
    • (1997) Foot Ankle Int. , vol.18 , pp. 128-131
    • Hovis, W.D.1    Bucholz, R.W.2
  • 24
    • 0036056819 scopus 로고    scopus 로고
    • Treatment of syndesmotic disruptions of the ankle with bioabsorable screw fixation
    • Hovis, W. D., B. W. Kaiser, J. T. Watson, and R. W. Bucholz. Treatment of syndesmotic disruptions of the ankle with bioabsorable screw fixation. J. Bone Joint Surg. Am. 84:26-31, 2002.
    • (2002) J. Bone Joint Surg. Am. , vol.84 , pp. 26-31
    • Hovis, W.D.1    Kaiser, B.W.2    Watson, J.T.3    Bucholz, R.W.4
  • 27
    • 0036932999 scopus 로고    scopus 로고
    • Complications in the fisrt 1043 operations where self-reinforced poly-L-lactide implants were used solely for tissue fixation in orthopedics and traumatology
    • Juutilainen, T., E. Hirvensalo, E. K. Partio, H. Patiala, P. Tormala, and P. Rokkanen. Complications in the fisrt 1043 operations where self-reinforced poly-L-lactide implants were used solely for tissue fixation in orthopedics and traumatology. Int. Orthop. 26:122-125, 2002.
    • (2002) Int. Orthop. , vol.26 , pp. 122-125
    • Juutilainen, T.1    Hirvensalo, E.2    Partio, E.K.3    Patiala, H.4    Tormala, P.5    Rokkanen, P.6
  • 28
    • 0032134717 scopus 로고    scopus 로고
    • Operative treatment of displaced intra-articular fractures of the calcaneus using absorbable internal fixation: A prospective study of twenty-five fractures
    • Kankare, J. Operative treatment of displaced intra-articular fractures of the calcaneus using absorbable internal fixation: A prospective study of twenty-five fractures. J. Orthop. Trauma 12:413-419, 1998.
    • (1998) J. Orthop. Trauma , vol.12 , pp. 413-419
    • Kankare, J.1
  • 30
    • 0002680486 scopus 로고    scopus 로고
    • Bioresorbable and bioerodable materials
    • edited by B. D. Ratner, A. S. Huffman, F. J. Schoen, and J. E. Lemons. San Diego, CA: Elsevier
    • Kohn, J., and R. Langer. Bioresorbable and bioerodable materials. In: Biomaterials Science: An Introduction to Materials in Medicine, edited by B. D. Ratner, A. S. Huffman, F. J. Schoen, and J. E. Lemons. San Diego, CA: Elsevier, 1996, pp. 64-72.
    • (1996) Biomaterials Science: An Introduction to Materials in Medicine , pp. 64-72
    • Kohn, J.1    Langer, R.2
  • 33
    • 0033062398 scopus 로고    scopus 로고
    • Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone
    • Lajtai, G. L., K. Humer, G. Aitzemuller, F. Unger, I. Noszian, and E. Orthner. Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone. Arthroscopy 15:481-488, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 481-488
    • Lajtai, G.L.1    Humer, K.2    Aitzemuller, G.3    Unger, F.4    Noszian, I.5    Orthner, E.6
  • 34
    • 0037316690 scopus 로고    scopus 로고
    • Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures: A prospective clinical trial of two amorphous 1-/dl-lactide copolymer 2-mm miniplate systems
    • Landes, C. A., S. Kriener, M. Menzer, and A. F. Kovacs. Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures: A prospective clinical trial of two amorphous 1-/dl-lactide copolymer 2-mm miniplate systems. Plast. Reconstr. Surg. 111:601-610, 2003.
    • (2003) Plast. Reconstr. Surg. , vol.111 , pp. 601-610
    • Landes, C.A.1    Kriener, S.2    Menzer, M.3    Kovacs, A.F.4
  • 35
    • 0037229413 scopus 로고    scopus 로고
    • Tendon transfer fixation in the foot and ankle: A biomechanical study evaluating two sizes of pilot holes for bioabsorbable screws
    • Louden, K. W., C. G. Ambrose, S. G. Beaty, W. C. McGarvey, and T. O. Clanton. Tendon transfer fixation in the foot and ankle: A biomechanical study evaluating two sizes of pilot holes for bioabsorbable screws. Foot Ankle Int. 24:67-72, 2003.
    • (2003) Foot Ankle Int. , vol.24 , pp. 67-72
    • Louden, K.W.1    Ambrose, C.G.2    Beaty, S.G.3    McGarvey, W.C.4    Clanton, T.O.5
  • 36
    • 63549137294 scopus 로고    scopus 로고
    • Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction
    • MacDonald, P., and S. Arneja. Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 19:E54, 2003.
    • (2003) Arthroscopy , vol.19
    • Macdonald, P.1    Arneja, S.2
  • 37
    • 0032957063 scopus 로고    scopus 로고
    • Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation
    • Martinek, V., and N. F. Friederich. Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317-320, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 317-320
    • Martinek, V.1    Friederich, N.F.2
  • 38
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    • McGuire, D. A., F. A. Barber, B. F. Elrod, and L. E. Paulos. Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15:463-473, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3    Paulos, L.E.4
  • 39
    • 0034580276 scopus 로고    scopus 로고
    • Synthetic biodegradable polymers as orthopedic devices
    • Middleton, J. C., and A. J. Tipton. Synthetic biodegradable polymers as orthopedic devices. Biomaterials 21:2335-2346, 2000.
    • (2000) Biomaterials , vol.21 , pp. 2335-2346
    • Middleton, J.C.1    Tipton, A.J.2
  • 40
    • 0035059546 scopus 로고    scopus 로고
    • Intraosseous bioabsorbable poly-L-lactic acid screw presenting as a late foreign-body reaction: A case report
    • Mosier-LaClair, S., H. Pike, and G. Pomeroy. Intraosseous bioabsorbable poly-L-lactic acid screw presenting as a late foreign-body reaction: A case report. Foot Ankle Int. 22:247-251, 2001.
    • (2001) Foot Ankle Int. , vol.22 , pp. 247-251
    • Mosier-Laclair, S.1    Pike, H.2    Pomeroy, G.3
  • 41
    • 0036348607 scopus 로고    scopus 로고
    • Osteolysis after open shoulder stabilization using a new bioresorbable bone anchor: A prospective, non-randomized clinical trial
    • Muller, M., M. J. Kaab, C. Villiger, and P. Holzach. Osteolysis after open shoulder stabilization using a new bioresorbable bone anchor: A prospective, non-randomized clinical trial. Injury 33:30-36, 2002.
    • (2002) Injury , vol.33 , pp. 30-36
    • Muller, M.1    Kaab, M.J.2    Villiger, C.3    Holzach, P.4
  • 42
    • 0027537539 scopus 로고
    • Intraosseous cellular response to biodegradable fracture fixation screws made of polyglycolide or polylactide
    • Paivarinta, U., O. Bostman, A. Majola, T. Toivonen, P. Tormala, and P. Rokkanen. Intraosseous cellular response to biodegradable fracture fixation screws made of polyglycolide or polylactide. Arch. Orthop. Trauma Surg. 112:71-74, 1993.
    • (1993) Arch. Orthop. Trauma Surg. , vol.112 , pp. 71-74
    • Paivarinta, U.1    Bostman, O.2    Majola, A.3    Toivonen, T.4    Tormala, P.5    Rokkanen, P.6
  • 44
    • 0031036032 scopus 로고    scopus 로고
    • Osteolytic changes after polyglycolide pin fixation in chevron osteotomy
    • Pelto-Vasenius, K., E. Hirvensalo, J. Vasenius, and P. Rokkanen. Osteolytic changes after polyglycolide pin fixation in chevron osteotomy. Foot Ankle Int. 18:21-25, 1997.
    • (1997) Foot Ankle Int. , vol.18 , pp. 21-25
    • Pelto-Vasenius, K.1    Hirvensalo, E.2    Vasenius, J.3    Rokkanen, P.4
  • 45
    • 0030015909 scopus 로고    scopus 로고
    • Bioresorbable implants - Practical considerations
    • Pietrzak, W. S., D. Sarver, and M. Verstynen. Bioresorbable implants - practical considerations. Bone 19:1098-1198, 1996.
    • (1996) Bone , vol.19 , pp. 1098-1198
    • Pietrzak, W.S.1    Sarver, D.2    Verstynen, M.3
  • 46
    • 0037491290 scopus 로고    scopus 로고
    • Tendon transfer fixation: Comparing a tendon to tendon technique vs. Bioabsorbable interference-fit screw fixation
    • Sabonghy, E. P., R. M. Wood, C. G. Ambrose, W. C. McGarvey, and T. O. Clanton. Tendon transfer fixation: Comparing a tendon to tendon technique vs. Bioabsorbable interference-fit screw fixation. Foot Ankle Int. 24:260-262, 2003.
    • (2003) Foot Ankle Int. , vol.24 , pp. 260-262
    • Sabonghy, E.P.1    Wood, R.M.2    Ambrose, C.G.3    McGarvey, W.C.4    Clanton, T.O.5
  • 47
    • 0034820029 scopus 로고    scopus 로고
    • Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel
    • Selby, J. B., D. L. Johnson, P. Hester, and D. N. M. Caborn. Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am. J. Sports Med. 29:614-619, 2001.
    • (2001) Am. J. Sports Med. , vol.29 , pp. 614-619
    • Selby, J.B.1    Johnson, D.L.2    Hester, P.3    Caborn, D.N.M.4
  • 48
    • 34047228962 scopus 로고    scopus 로고
    • Broken poly-L-lactic acid interference screw after ligament reconstruction
    • Shafer, B. L., and P. T. Simonian. Broken poly-L-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35, 2002.
    • (2002) Arthroscopy , vol.18
    • Shafer, B.L.1    Simonian, P.T.2
  • 49
    • 0027315403 scopus 로고
    • Arthroscopic shoulder stabilization: A role for biodegradable materials
    • Speer, K. P., and R. F. Warren. Arthroscopic shoulder stabilization: A role for biodegradable materials. Clin. Orthop. 291:67-74, 1993.
    • (1993) Clin. Orthop. , vol.291 , pp. 67-74
    • Speer, K.P.1    Warren, R.F.2
  • 50
    • 0030903593 scopus 로고    scopus 로고
    • Clinical degradation and biocompatibility or different bioabsorbable interference screws: A report of 6 cases
    • Stahelin, A. C., A. Weiler, H. Rufenacht, R. Hoffman, A. Geissmann, and R. Feinstein. Clinical degradation and biocompatibility or different bioabsorbable interference screws: A report of 6 cases. Arthroscopy 13:238-244, 1997.
    • (1997) Arthroscopy , vol.13 , pp. 238-244
    • Stahelin, A.C.1    Weiler, A.2    Rufenacht, H.3    Hoffman, R.4    Geissmann, A.5    Feinstein, R.6
  • 51
    • 0031949295 scopus 로고    scopus 로고
    • A 5-year in vitro and in vivo study of the biodegradation of polylactide plates
    • Suuronen, R., T. Pohjonen, J. Hietanen, and C. Lindqvist. A 5-year in vitro and in vivo study of the biodegradation of polylactide plates. J. Oral. Maxillofac. Surg. 56:604-614, 1998.
    • (1998) J. Oral. Maxillofac. Surg. , vol.56 , pp. 604-614
    • Suuronen, R.1    Pohjonen, T.2    Hietanen, J.3    Lindqvist, C.4
  • 52
    • 0031970510 scopus 로고    scopus 로고
    • Foreign body gonitis caused by a broken poly-L-lactic acid screw
    • Takizawa, T., S. Akizuki, H. Horiuchi, and Y. Yasukawa. Foreign body gonitis caused by a broken poly-L-lactic acid screw. Arthroscopy 14:329-330, 1998.
    • (1998) Arthroscopy , vol.14 , pp. 329-330
    • Takizawa, T.1    Akizuki, S.2    Horiuchi, H.3    Yasukawa, Y.4
  • 55
    • 0033023293 scopus 로고    scopus 로고
    • Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after cruciate ligament reconstruction
    • Warden, W. H., R. Friedman, L. M. Teresi, and D. W. Jackson. Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after cruciate ligament reconstruction. Arthroscopy 15:474-480, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 474-480
    • Warden, W.H.1    Friedman, R.2    Teresi, L.M.3    Jackson, D.W.4
  • 56
    • 0036488211 scopus 로고    scopus 로고
    • Tendon healing in a bone tunnel. Part ii: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep
    • Weiler, A., R. F. G. Hoffmann, H. J. Bail, O. Rehm, and N. P. Sudkamp. Tendon healing in a bone tunnel. Part ii: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18:124-135, 2002.
    • (2002) Arthroscopy , vol.18 , pp. 124-135
    • Weiler, A.1    Hoffmann, R.F.G.2    Bail, H.J.3    Rehm, O.4    Sudkamp, N.P.5
  • 57
    • 0031931882 scopus 로고    scopus 로고
    • Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone
    • Weiler, A., R. F. G. Hoffmann, A. C. Stahelin, H. J. Bail, C. J. Siepe, and N. P. Sudkamp. Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone. Arthroscopy 14:29-37, 1998.
    • (1998) Arthroscopy , vol.14 , pp. 29-37
    • Weiler, A.1    Hoffmann, R.F.G.2    Stahelin, A.C.3    Bail, H.J.4    Siepe, C.J.5    Sudkamp, N.P.6
  • 58
    • 0036488127 scopus 로고    scopus 로고
    • Tendon healing in a bone tunnel. Part 1: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep
    • Weiler, A., R. Peine, A. Pashmineh-Azar, C. Abel, N. P. Sudkamp, and R. F. G. Hoffmann. Tendon healing in a bone tunnel. Part 1: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18:113-123, 2002.
    • (2002) Arthroscopy , vol.18 , pp. 113-123
    • Weiler, A.1    Peine, R.2    Pashmineh-Azar, A.3    Abel, C.4    Sudkamp, N.P.5    Hoffmann, R.F.G.6
  • 59
    • 0036357684 scopus 로고    scopus 로고
    • Secondary intraarticular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction
    • Werner, A., A. Wild, A Ilg, and R. Karauspe. Secondary intraarticular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg. Sports Traumatol. Arthrosc. 10:30-32, 2002.
    • (2002) Knee Surg. Sports Traumatol. Arthrosc. , vol.10 , pp. 30-32
    • Werner, A.1    Wild, A.2    Ilg, A.3    Karauspe, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.