메뉴 건너뛰기




Volumn 224, Issue 7, 2010, Pages 1435-1454

Force sensing and its application in minimally invasive surgery and therapy: A survey

Author keywords

force sensors; haptics; minimally invasive surgery and therapy; sensing technologies; sensor design

Indexed keywords

FORCE SENSOR; HAPTICS; MINIMALLY INVASIVE SURGERY; SENSING TECHNOLOGY; SENSOR DESIGNS;

EID: 77954835805     PISSN: 09544062     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544062JMES1917     Document Type: Review
Times cited : (172)

References (126)
  • 1
    • 0032168837 scopus 로고    scopus 로고
    • Safety and cost-effectiveness of midcabg in high-risk cabg patients
    • DelRizzo, D. F., Boyd, W. D., and Novick, R. J. Safety and cost-effectiveness of midcabg in high-risk cabg patients. Ann. Thorac. Surg., 1998, 66, 1002-1007.
    • (1998) Ann. Thorac. Surg. , vol.66 , pp. 1002-1007
    • Delrizzo, D.F.1    Boyd, W.D.2    Novick, R.J.3
  • 4
    • 39749088130 scopus 로고    scopus 로고
    • State of the art in force and tactile sensing for minimally invasive surgery
    • Puangmali, P., Altheofer, K., Seneviratne, L. D., Murphy, D., and Dasgupta, P. State of the art in force and tactile sensing for minimally invasive surgery. IEEE Sens. J., 2008, 8(4), 371-381.
    • (2008) IEEE Sens. J. , vol.8 , Issue.4 , pp. 371-381
    • Puangmali, P.1    Altheofer, K.2    Seneviratne, L.D.3    Murphy, D.4    Dasgupta, P.5
  • 5
    • 67651244385 scopus 로고    scopus 로고
    • The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: A current review
    • Van der Meijden, O. A. J. and Schijven, M. P. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surg. Endosc., 2009, 23, 1180-1190.
    • (2009) Surg. Endosc. , vol.23 , pp. 1180-1190
    • Van Der Meijden, O.A.J.1    Schijven, M.P.2
  • 12
    • 9144241800 scopus 로고    scopus 로고
    • Methods for haptic feedback in teleoperated robot-assisted surgery
    • Okamura, A. M.Methods for haptic feedback in teleoperated robot-assisted surgery. Ind. Robot: Int. J., 2004, 31(6), 499-508.
    • (2004) Ind. Robot: Int. J. , vol.31 , Issue.6 , pp. 499-508
    • Okamura, A.M.1
  • 17
    • 11144282530 scopus 로고    scopus 로고
    • Effect of sensory substitution on suture-manipulation forces for robotic surgical systems
    • Kitagawa, M., Dokko, D., Okamura, A. M., and Yuh, D. Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. J. Thorac. Cardiovasc. Surg., 2005, 129(1), 151-158.
    • (2005) J. Thorac. Cardiovasc. Surg. , vol.129 , Issue.1 , pp. 151-158
    • Kitagawa, M.1    Dokko, D.2    Okamura, A.M.3    Yuh, D.4
  • 22
    • 33846044602 scopus 로고    scopus 로고
    • Needle insertion into soft tissue: A survey
    • Abolhassani, N., Patel, R., and Moallem, M. Needle insertion into soft tissue: a survey.Med. Eng. Phys., 2007, 29(4), 413-431.
    • (2007) Med. Eng. Phys. , vol.29 , Issue.4 , pp. 413-431
    • Abolhassani, N.1    Patel, R.2    Moallem, M.3
  • 24
    • 77954841067 scopus 로고    scopus 로고
    • The must-have in robotic heart surgery: Haptic feedback
    • (I-Tech Education and Publishing, Vienna, Austria)
    • Braun, E. U., Mayer, H., Knoll, A., Lange, R., and Bauernschmitt, R. The must-have in robotic heart surgery: haptic feedback. Medical robotics, 2008, pp. 9-20 (I-Tech Education and Publishing, Vienna, Austria).
    • (2008) Medical Robotics , pp. 9-20
    • Braun, E.U.1    Mayer, H.2    Knoll, A.3    Lange, R.4    Bauernschmitt, R.5
  • 26
    • 84974733353 scopus 로고    scopus 로고
    • Analysis of suture manipulation forces for teleoperation with force feedback
    • (Eds T. Dohi and R. Kikinis), Lecture notes in computer science (LNCS) (Tokyo, Japan)
    • Kitagawa, M., Okamura, A. M., Bethea, B. T., Gott, V. L., and Baumgartner,W. A. Analysis of suture manipulation forces for teleoperation with force feedback. In Medical image computing and computer assisted intervention (Eds T. Dohi and R. Kikinis), Lecture notes in computer science (LNCS), vol.2488, 2002, pp. 155-162 (Tokyo, Japan).
    • (2002) Medical Image Computing and Computer Assisted Intervention , vol.2488 , pp. 155-162
    • Kitagawa, M.1    Okamura, A.M.2    Bethea, B.T.3    Gott, V.L.4    Baumgartner, W.A.5
  • 27
    • 0033122728 scopus 로고    scopus 로고
    • Force-feedback grasper helps restore sense of touch in minimally invasive surgery
    • MacFarlane, M., Rosen, J., Hannaford, B., Pellegrini, C., and Sinanan, M. Force-feedback grasper helps restore sense of touch in minimally invasive surgery. J. Gastrointest. Surg., 1999, 3(3), 278-285.
    • (1999) J. Gastrointest. Surg. , vol.3 , Issue.3 , pp. 278-285
    • MacFarlane, M.1    Rosen, J.2    Hannaford, B.3    Pellegrini, C.4    Sinanan, M.5
  • 30
    • 11144258727 scopus 로고    scopus 로고
    • Force feedback plays a significant role in minimally invasive surgery
    • Tholey, G., Desai, J. P., and Castellanos, A. E. Force feedback plays a significant role in minimally invasive surgery. Ann. Surg., 2005, 241(1), 102-109.
    • (2005) Ann. Surg. , vol.241 , Issue.1 , pp. 102-109
    • Tholey, G.1    Desai, J.P.2    Castellanos, A.E.3
  • 31
    • 39049117868 scopus 로고    scopus 로고
    • Development of force measure system for clinical use in minimal access surgery
    • Hanna, G. B., Drew, T., Arnold, G., Fakhry, M., and Cuschieri, A. Development of force measure system for clinical use in minimal access surgery. Surg. Endosc., 2007, 22(2), 467-471.
    • (2007) Surg. Endosc. , vol.22 , Issue.2 , pp. 467-471
    • Hanna, G.B.1    Drew, T.2    Arnold, G.3    Fakhry, M.4    Cuschieri, A.5
  • 32
    • 77954858575 scopus 로고    scopus 로고
    • Force sensing in natural orifice transluminal endoscopic surgery
    • submitted for publication
    • Trejos, A. L., Jayaraman, S., Patel, R. V., Naish, M. D., and Schlachta, C. M. Force sensing in natural orifice transluminal endoscopic surgery. Surg. Endosc., 2009, submitted for publication.
    • (2009) Surg. Endosc.
    • Trejos, A.L.1    Jayaraman, S.2    Patel, R.V.3    Naish, M.D.4    Schlachta, C.M.5
  • 34
    • 0032861335 scopus 로고    scopus 로고
    • Force controlled and teleoperated endoscopic grasper for minimally invasive surgery - Experimental performance evaluation
    • Rosen, J. and Hannaford, B. Force controlled and teleoperated endoscopic grasper for minimally invasive surgery - experimental performance evaluation. IEEE Trans. Biomed. Engng, 1999, 46(10), 1212-1221.
    • (1999) IEEE Trans. Biomed. Engng , vol.46 , Issue.10 , pp. 1212-1221
    • Rosen, J.1    Hannaford, B.2
  • 36
    • 33344474734 scopus 로고    scopus 로고
    • Generalized approach for modeling minimally invasive surgery as a stochastic process using a discrete markov model
    • Rosen, J., Brown, J. D., Chang, L., Sinanan, M., and Hannaford, B. Generalized approach for modeling minimally invasive surgery as a stochastic process using a discrete markov model. IEEE Trans. Biomed. Engng, 2006, 53(3), 399-413.
    • (2006) IEEE Trans. Biomed. Engng , vol.53 , Issue.3 , pp. 399-413
    • Rosen, J.1    Brown, J.D.2    Chang, L.3    Sinanan, M.4    Hannaford, B.5
  • 42
    • 16844371079 scopus 로고    scopus 로고
    • What can the operator actually feel when performing a laparoscopy?
    • Picod, G., Jambon, A. C., Vinatier, D., and Dubois, P. What can the operator actually feel when performing a laparoscopy? Surg. Endosc., 2005, 19, 95-100.
    • (2005) Surg. Endosc. , vol.19 , pp. 95-100
    • Picod, G.1    Jambon, A.C.2    Vinatier, D.3    Dubois, P.4
  • 45
    • 32044466197 scopus 로고    scopus 로고
    • Haptic interaction in robot-assisted endoscopic surgery: A sensorized end-effector
    • Tavakoli, M., Patel, R. V., and Moallem, M. Haptic interaction in robot-assisted endoscopic surgery: a sensorized end-effector. Int. J. Med. Robot. Comput. Assist. Surg., 2005, 1(2), 53-63.
    • (2005) Int. J. Med. Robot. Comput. Assist. Surg. , vol.1 , Issue.2 , pp. 53-63
    • Tavakoli, M.1    Patel, R.V.2    Moallem, M.3
  • 46
    • 35048903089 scopus 로고    scopus 로고
    • Design development, and testing of an automated laparoscopic grasper with 3-D force measurement capability
    • Cambridge, MA, USA, 17-18 June
    • Tholey, G., Pillarisetti, A., Green, W., and Desai, J. P. Design, development, and testing of an automated laparoscopic grasper with 3-D force measurement capability. In Proceedings of the International Symposium on Medical simulation, Cambridge, MA, USA, 17-18 June 2004, pp. 38-48.
    • (2004) Proceedings of the International Symposium on Medical Simulation , pp. 38-48
    • Tholey, G.1    Pillarisetti, A.2    Green, W.3    Desai, J.P.4
  • 49
    • 0036134169 scopus 로고    scopus 로고
    • In vivo measurement of surgical gestures
    • Dubois, P. In vivo measurement of surgical gestures. IEEE Trans. Biomed. Engng, 2002, 49(1), 49-54.
    • (2002) IEEE Trans. Biomed. Engng , vol.49 , Issue.1 , pp. 49-54
    • Dubois, P.1
  • 51
    • 0345255043 scopus 로고    scopus 로고
    • A molecular 2-dof force-sensing instrument for laparoscopic surgery
    • (Eds R. E. Ellis and T. M. Peters), Lecture notes in computer science (LNCS) (Brittany, France)
    • Prasad, S. K., Kitagawa, M., Fischer, G. S., Zand, J., Talamini, M. A., Taylor, R. H., and Okamura, A. M. A molecular 2-dof force-sensing instrument for laparoscopic surgery. In Medical image computing and computer assisted intervention, (Eds R. E. Ellis and T. M. Peters), Lecture notes in computer science (LNCS), vol.2878, 2003, pp. 279-286 (Brittany, France).
    • (2003) Medical Image Computing and Computer Assisted Intervention , vol.2878 , pp. 279-286
    • Prasad, S.K.1    Kitagawa, M.2    Fischer, G.S.3    Zand, J.4    Talamini, M.A.5    Taylor, R.H.6    Okamura, A.M.7
  • 52
    • 34247381516 scopus 로고    scopus 로고
    • Mechatronic design of a new robot force control in minimally invasive surgery
    • Zemiti, N., Morel, G., and Ortmainer, T. Mechatronic design of a new robot force control in minimally invasive surgery. Trans.Mechatronics, 2007, 12(2), 143-151.
    • (2007) Trans. Mechatronics , vol.12 , Issue.2 , pp. 143-151
    • Zemiti, N.1    Morel, G.2    Ortmainer, T.3
  • 54
    • 37549071040 scopus 로고    scopus 로고
    • Friction compensation for enhancing transparency of a teleoperator with compliant transmission
    • Mahvash, M. and Okamura, A. M. Friction compensation for enhancing transparency of a teleoperator with compliant transmission. IEEE Trans. Robot. Autom., 2007, 23(6), 1240-1246.
    • (2007) IEEE Trans. Robot. Autom. , vol.23 , Issue.6 , pp. 1240-1246
    • Mahvash, M.1    Okamura, A.M.2
  • 55
    • 20344383987 scopus 로고    scopus 로고
    • A parallel robotic system with force sensors for percutaneous procedures underCT-guidance
    • (Eds C. Barillot, D. R. Haynor, and P. Hellier), Lecture notes in computer science (LNCS)
    • Maurin, B.,Gangloff, J.,Bayle, B., deMathelin, M.,Piccin, O.,Zanne,P.,Doignon, C., Soler, L., and Gangi, A. A parallel robotic system with force sensors for percutaneous procedures underCT-guidance. InMedical image computing and computer assisted intervention (Eds C. Barillot, D. R. Haynor, and P. Hellier), Lecture notes in computer science (LNCS), vol.3217, 2004, pp. 176-183.
    • (2004) Medical Image Computing and Computer Assisted Intervention , vol.3217 , pp. 176-183
    • Maurin, B.1    Gangloff, J.2    Bayle, B.3    Demathelin, M.4    Piccin, M.5    Zanne, P.6    Doignon, C.7    Soler, L.8    Gangi, A.9
  • 56
    • 20344383988 scopus 로고    scopus 로고
    • Needle force sensor, robust and sensitive detection of the instant of needle puncture
    • Brittany, France, 26-30 September
    • Washio, T. and Chinzei, K. Needle force sensor, robust and sensitive detection of the instant of needle puncture. InMedical image computingandcomputer assisted intervention, Brittany, France, 26-30 September 2004, pp. 113-120.
    • (2004) Medical Image Computingandcomputer Assisted Intervention , pp. 113-120
    • Washio, T.1    Chinzei, K.2
  • 57
    • 84974678912 scopus 로고    scopus 로고
    • Measurement of the tip and friction force acting on a needle during penetration
    • (Eds T. Dohi and R. Kikinis), Lecture notes in computer science (LNCS)
    • Kataoka, H., Washio, T., Chinzei, K., Mizuhara, K., Simone, C., and Okamura, A. Measurement of the tip and friction force acting on a needle during penetration. In Medical image computing and computer assisted intervention (Eds T. Dohi and R. Kikinis), Lecture notes in computer science (LNCS), vol.2488, 2002, pp. 216-223.
    • (2002) Medical Image Computing and Computer Assisted Intervention , vol.2488 , pp. 216-223
    • Kataoka, H.1    Washio, T.2    Chinzei, K.3    Mizuhara, K.4    Simone, C.5    Okamura, A.6
  • 61
    • 55749101894 scopus 로고    scopus 로고
    • A compact and modular laparoscopic grasper with tridirectional force measurement capability
    • Tholey, G. and Desai, J. P. A compact and modular laparoscopic grasper with tridirectional force measurement capability. J. Med. Dev., 2008, 2, 031001-1- 031001-31008
    • (2008) J. Med. Dev. , vol.2 , pp. 0310011-03100131008
    • Tholey, G.1    Desai, J.P.2
  • 62
    • 0142196055 scopus 로고    scopus 로고
    • A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation
    • Berkelman, P. J., Whitcomb, L. L., Taylor, R. H., and Jensen, P. A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation. IEEE Trans. Robot. Autom., 2003, 19(5), 917-922.
    • (2003) IEEE Trans. Robot. Autom. , vol.19 , Issue.5 , pp. 917-922
    • Berkelman, P.J.1    Whitcomb, L.L.2    Taylor, R.H.3    Jensen, P.4
  • 63
    • 0036725078 scopus 로고    scopus 로고
    • A novel six-component force sensor of good measurement isotropy and sensitivities
    • Liu, S. A. and Tzo, H. L. A novel six-component force sensor of good measurement isotropy and sensitivities. Sens. Actuators A, Phys., 2002, 100(2-3), 223-230.
    • (2002) Sens. Actuators A, Phys. , vol.100 , Issue.2-3 , pp. 223-230
    • Liu, S.A.1    Tzo, H.L.2
  • 64
    • 3042824648 scopus 로고    scopus 로고
    • A force-torque sensor based on a stewart platformin a near-singular configuration
    • Ranganath, R., Nair, P. S., Mruthyunjaya, T. S., and Ghosal, A. A force-torque sensor based on a stewart platformin a near-singular configuration.Mech.Mach. Theory, 2004, 39(9), 971-998.
    • (2004) Mech. Mach. Theory , vol.39 , Issue.9 , pp. 971-998
    • Ranganath, R.1    Nair, P.S.2    Mruthyunjaya, T.S.3    Ghosal, A.4
  • 65
    • 0026219524 scopus 로고
    • A systematic design to minimize a performance index for robot force sensors
    • Uchiyama, M., Bayo, E., and Palma-Villalon, E. A systematic design to minimize a performance index for robot force sensors. J. Dyn. Syst. Meas. Control, 1991, 113(3), 388-395.
    • (1991) J. Dyn. Syst. Meas. Control , vol.113 , Issue.3 , pp. 388-395
    • Uchiyama, M.1    Bayo, E.2    Palma-Villalon, E.3
  • 66
    • 0031256904 scopus 로고    scopus 로고
    • Shape optimal design and force sensitivity evaluation of six-axis force sensors
    • Chao, L.-P. and Chen, K.-T. Shape optimal design and force sensitivity evaluation of six-axis force sensors. Sens. Actuators A, Phys., 1997, 63(2), 105-112.
    • (1997) Sens. Actuators A, Phys. , vol.63 , Issue.2 , pp. 105-112
    • Chao, L.-P.1    Chen, K.-T.2
  • 67
    • 0027543025 scopus 로고
    • Mechanical analysis of a novel six-degree-of-freedom wrist force sensor
    • Huang,W., Jiang, H., and Zhou, H. Mechanical analysis of a novel six-degree-of-freedom wrist force sensor. Sens. Actuators A, Phys., 1993, 35, 203-208.
    • (1993) Sens. Actuators A, Phys. , vol.35 , pp. 203-208
    • Huang, W.1    Jiang, H.2    Zhou, H.3
  • 70
    • 77954857542 scopus 로고    scopus 로고
    • US patent no. 6 823 744 B2, Honda giken kogyo kabushiki kaisha, Tokyo (JP), USA
    • Ohsato,T. and Hirabayashi,Y. Six-axis force sensor. US patent no.6 823 744 B2, Honda giken kogyo kabushiki kaisha, Tokyo (JP), USA, 2004.
    • (2004) Six-axis Force Sensor
    • Ohsato, T.1    Hirabayashi, Y.2
  • 71
  • 72
  • 73
    • 33947358665 scopus 로고    scopus 로고
    • Modeling of force sensing and validation of disturbance observer for force control
    • Katsura, S., Matsumoto, Y., and Ohnishi, K. Modeling of force sensing and validation of disturbance observer for force control. IEEE Trans. Ind. Electron., 2007, 54(1), 530-538.
    • (2007) IEEE Trans. Ind. Electron. , vol.54 , Issue.1 , pp. 530-538
    • Katsura, S.1    Matsumoto, Y.2    Ohnishi, K.3
  • 76
    • 77954848829 scopus 로고    scopus 로고
    • A sensorized instrument for skills assessment and training in minimally invasive surgery
    • Trejos, A. L., Patel, R. V., Naish, M. D., and Schlachta, C. M. A sensorized instrument for skills assessment and training in minimally invasive surgery. ASME J. Med. Dev., 2009, 3(4), 041002-1-041002-41012
    • (2009) ASME J. Med. Dev. , vol.3 , Issue.4 , pp. 0410021-04100241012
    • Trejos, A.L.1    Patel, R.V.2    Naish, M.D.3    Schlachta, C.M.4
  • 82
    • 0023965731 scopus 로고
    • An advanced robot system for automated diagnostic tasks through palpation
    • Dario, P. and Bergamasco, M. An advanced robot system for automated diagnostic tasks through palpation. IEEE Trans. Biomed. Engng, 1988, 35(2), 118-126.
    • (1988) IEEE Trans. Biomed. Engng , vol.35 , Issue.2 , pp. 118-126
    • Dario, P.1    Bergamasco, M.2
  • 84
    • 0031598888 scopus 로고    scopus 로고
    • A review on the modelling of piezoelectric sensors and actuators incorporated in intelligent structures
    • Chee, C.Y. K.,Tong, L., and Steven, G. P. A review on the modelling of piezoelectric sensors and actuators incorporated in intelligent structures. J. Intell. Mater. Syst. Struct., 1998, 9(1), 3-19.
    • (1998) J. Intell. Mater. Syst. Struct. , vol.9 , Issue.1 , pp. 3-19
    • Chee, C.Y.K.1    Tong, L.2    Steven, G.P.3
  • 85
  • 86
    • 77954857407 scopus 로고
    • US Patent no. 4 092 854, The Bendix Corporation, USA
    • Henry, J. L. and Ruoff, C. R. J. Multi-axis load cell. US Patent no.4 092 854, The Bendix Corporation, USA, 1978.
    • (1978) Multi-axis Load Cell
    • Henry, J.L.1    Ruoff, C.R.J.2
  • 87
    • 77954857265 scopus 로고    scopus 로고
    • US patent no. US RE36 065 E, Bonneville Scientific incorporation, Salt Lake City, UT, USA
    • Grahn, A. R. Triaxial normal and shear force sensor. US patent no. US RE36 065 E, Bonneville Scientific incorporation, Salt Lake City, UT, USA, 2001.
    • (2001) Triaxial Normal and Shear Force Sensor
    • Grahn, A.R.1
  • 89
    • 0005731216 scopus 로고    scopus 로고
    • Computer-controlled motorized endoscopic grasper for in vivo measurement of soft tissue biomechanical characteristics
    • Newport Beach, CA, 23-26 January
    • Brown, J. D., Rosen, J., Moreyra, M., Sinanan, M., and Hannaford, B. Computer-controlled motorized endoscopic grasper for in vivo measurement of soft tissue biomechanical characteristics. In Medicine meets virtual reality, Newport Beach, CA, 23-26 January 2002, pp. 71-73.
    • (2002) Medicine Meets Virtual Reality , pp. 71-73
    • Brown, J.D.1    Rosen, J.2    Moreyra, M.3    Sinanan, M.4    Hannaford, B.5
  • 90
    • 41949102580 scopus 로고    scopus 로고
    • Biocompatibility: Meeting a key functional requirement of next-generation medical devices
    • Helmus, M. N., Gibbons, D. F., and Cebon, D. Biocompatibility: meeting a key functional requirement of next-generation medical devices. Toxicol. Pathol., 2008, 36(1), 70-80.
    • (2008) Toxicol. Pathol. , vol.36 , Issue.1 , pp. 70-80
    • Helmus, M.N.1    Gibbons, D.F.2    Cebon, D.3
  • 92
    • 0024471452 scopus 로고
    • Sterilization of medical devices: A review
    • Dempsey, D. J. and Thirucote, R. R. Sterilization of medical devices: a review. J. Biomater. Appl., 1988, 3(3), 454-523.
    • (1988) J. Biomater. Appl. , vol.3 , Issue.3 , pp. 454-523
    • Dempsey, D.J.1    Thirucote, R.R.2
  • 93
    • 35548937840 scopus 로고    scopus 로고
    • Ethylene oxide sterilization of medical devices: A review
    • Mendes, G. C. C., Brandão, T. R. S., and Silva, C. L. M. Ethylene oxide sterilization of medical devices: a review. Am. J. Infect. Control, 2007, 35(9), 574-581.
    • (2007) Am. J. Infect. Control , vol.35 , Issue.9 , pp. 574-581
    • Mendes, G.C.C.1    Brandão, T.R.S.2    Silva, C.L.M.3
  • 94
    • 18844364648 scopus 로고    scopus 로고
    • Tactile sensing in intelligent robotic manipulation - A review
    • Tegin, J. and Wikander, J. Tactile sensing in intelligent robotic manipulation - a review. Ind. Robot: Int. J., 2005, 32(1), 64-70.
    • (2005) Ind. Robot: Int. J. , vol.32 , Issue.1 , pp. 64-70
    • Tegin, J.1    Wikander, J.2
  • 95
    • 84945559247 scopus 로고    scopus 로고
    • A miniature instrument tip force sensor for robot/human cooperative microsurgical manipulation with enhanced force feedback
    • Pittsburgh, Pennsylvania, USA, 11-14 October
    • Berkelman, P. J., Whitcomb, L. L., Taylor, R. H., and Jensen, P. A miniature instrument tip force sensor for robot/human cooperative microsurgical manipulation with enhanced force feedback. In Medical image computing and computer assisted intervention, Pittsburgh, Pennsylvania, USA, 11-14 October 2000, pp. 897-906.
    • (2000) Medical Image Computing and Computer Assisted Intervention , pp. 897-906
    • Berkelman, P.J.1    Whitcomb, L.L.2    Taylor, R.H.3    Jensen, P.4
  • 97
    • 14044272239 scopus 로고    scopus 로고
    • Robotic system to evaluate force feedback in minimally invasive computer aided surgery
    • Salt Lake City, Utah, USA, 28 September-2 October
    • Mayer, H., Nagy, I., and Knoll, A. Robotic system to evaluate force feedback in minimally invasive computer aided surgery. In Proceedings of the 2004 ASME Design Engineering Technical Conferences, Salt Lake City, Utah, USA, 28 September-2 October 2004, pp. 361-379.
    • (2004) Proceedings of the 2004 ASME Design Engineering Technical Conferences , pp. 361-379
    • Mayer, H.1    Nagy, I.2    Knoll, A.3
  • 99
    • 32044472140 scopus 로고    scopus 로고
    • A haptic interface for computer-integrated endoscopic surgery and training
    • Tavakoli, M., Patel, R., and Moallem, M. A haptic interface for computer-integrated endoscopic surgery and training.Virtual Real., 2006, 9(2), 160-176.
    • (2006) Virtual Real , vol.9 , Issue.2 , pp. 160-176
    • Tavakoli, M.1    Patel, R.2    Moallem, M.3
  • 110
    • 33947278495 scopus 로고    scopus 로고
    • Development of actuated and sensor integrated forceps for minimally invasive robotic surgery
    • Kuebler, B.,Seibold,U.,andHirzinger,G.Development of actuated and sensor integrated forceps for minimally invasive robotic surgery. Int. J. Med. Robot. Comput. Assist. Surg., 2005, 1(3), 96-107.
    • (2005) Int. J. Med. Robot. Comput. Assist. Surg. , vol.1 , Issue.3 , pp. 96-107
    • Kuebler, B.1    Seibold, U.2    Hirzinger, G.3
  • 111
    • 43249121660 scopus 로고    scopus 로고
    • Development of experimental analysis of a soft compliant tactile microsensor for anthropomorphic artificial hand
    • Beccai, L., Roccella, S., Ascari, L., Valdastri, P., Sieber, A.,Carrozza,M. C.,and Dario,P.Development of experimental analysis of a soft compliant tactile microsensor for anthropomorphic artificial hand. IEEE/ASME Trans. Mechatronics, 2008, 13(2), 158-168.
    • (2008) IEEE/ASME Trans. Mechatronics , vol.13 , Issue.2 , pp. 158-168
    • Beccai, L.1    Roccella, S.2    Ascari, L.3    Valdastri, P.4    Sieber, A.5    Carrozza, M.C.6    Dario, P.7
  • 115
    • 0032605263 scopus 로고    scopus 로고
    • Surgeon-tool force/torque signatures - Evaluation of surgical skills in minimally invasive surgery
    • San Francisco, CA
    • Rosen, J., MacFarlane, M., Richards, C., Hannaford, B., and Sinanan, M. Surgeon-tool force/torque signatures - evaluation of surgical skills in minimally invasive surgery. InMedicine meets virtual reality, San Francisco, CA, 1999, 290-296.
    • (1999) Medicine Meets Virtual Reality , pp. 290-296
    • Rosen, J.1    MacFarlane, M.2    Richards, C.3    Hannaford, B.4    Sinanan, M.5
  • 116
    • 0035032844 scopus 로고    scopus 로고
    • Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills
    • Rosen, J. and Hannaford, B.Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills. IEEE Trans. Biomed. Engng, 2001, 48(5), 579-591.
    • (2001) IEEE Trans. Biomed. Engng , vol.48 , Issue.5 , pp. 579-591
    • Rosen, J.1    Hannaford, B.2
  • 117
    • 0036015580 scopus 로고    scopus 로고
    • Task decomposition of laparoscopic surgery for objective evaluation of surgical residents' learning curve using hiddenmarkov model
    • Rosen, J., Solazzo, M.,Hannaford, B., and Sinanan, M. Task decomposition of laparoscopic surgery for objective evaluation of surgical residents' learning curve using hiddenmarkov model. Comput. Aided Surg., 2002, 7, 49-61.
    • (2002) Comput. Aided Surg. , vol.7 , pp. 49-61
    • Rosen, J.1    Solazzo, M.2    Hannaford, B.3    Sinanan, M.4
  • 119
    • 33744809566 scopus 로고    scopus 로고
    • Contact force measurement of instruments for force-feedback on a surgical robot: Acceleration force cancellations based on acceleration sensor readings
    • (Eds J. Duncan and G. Gerig), Lecture notes in computer science (LNCS) (Palm Springs, CA, USA)
    • Shimachi, S., Kameyama, F., Hakozaki, Y., and Fujiwara, Y. Contact force measurement of instruments for force-feedback on a surgical robot: acceleration force cancellations based on acceleration sensor readings. In Medical image computing and computer assisted intervention (Eds J. Duncan and G. Gerig), Lecture notes in computer science (LNCS), vol.3750, 2005, pp. 97-104 (Palm Springs, CA, USA).
    • (2005) Medical Image Computing and Computer Assisted Intervention , vol.3750 , pp. 97-104
    • Shimachi, S.1    Kameyama, F.2    Hakozaki, Y.3    Fujiwara, Y.4
  • 125
    • 9144268434 scopus 로고    scopus 로고
    • Onsite three dimensional force sensing capability in a laparoscopic grasper
    • Tholey, G., Pillarisetti, A., and Desai, J. P. Onsite three dimensional force sensing capability in a laparoscopic grasper. Ind. Robot Int. J., 2004, 31(6), 509-518.
    • (2004) Ind. Robot Int. J. , vol.31 , Issue.6 , pp. 509-518
    • Tholey, G.1    Pillarisetti, A.2    Desai, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.