메뉴 건너뛰기




Volumn , Issue , 2002, Pages 68-74

The role of force feedback in surgery: Analysis of blunt dissection

Author keywords

Arteries; Force feedback; Haptic interfaces; Hospitals; Minimally invasive surgery; Performance analysis; Robots; Surges; Surgical instruments; Telerobotics

Indexed keywords

DISSECTION; HAPTIC INTERFACES; HOSPITALS; INDUSTRIAL ROBOTS; MICE (COMPUTER PERIPHERALS); REMOTE CONTROL; ROBOTICS; ROBOTS; SURGERY; TISSUE; TRANSPLANTATION (SURGICAL); VIRTUAL REALITY;

EID: 84949786063     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/HAPTIC.2002.998943     Document Type: Conference Paper
Times cited : (316)

References (16)
  • 1
    • 0032168486 scopus 로고    scopus 로고
    • Computer-assisted telemanipulation: An enabling technology for endoscopic coronary artery bypass
    • H. Shennib, A. Bastawisy, M. J. Mack, and F. H. Moll, "Computer-assisted telemanipulation: An enabling technology for endoscopic coronary artery bypass, " Ann Thorac Surg, vol. 66, pp. 1060-3., 1998.
    • (1998) Ann Thorac Surg , vol.66 , pp. 1060-1063
    • Shennib, H.1    Bastawisy, A.2    Mack, M.J.3    Moll, F.H.4
  • 2
    • 0032168413 scopus 로고    scopus 로고
    • Robotically assisted microsurgery for endoscopic coronary artery bypass grafting
    • E. R. Stephenson, Jr., S. Sankholkar, C. T. Ducko, and R. J. Damiano, Jr., "Robotically assisted microsurgery for endoscopic coronary artery bypass grafting, " Ann Thorac Surg, vol. 66, pp. 1064-7., 1998.
    • (1998) Ann Thorac Surg , vol.66 , pp. 1064-1067
    • Stephenson, E.R.1    Sankholkar, S.2    Ducko, C.T.3    Damiano, R.J.4
  • 4
    • 0039842187 scopus 로고    scopus 로고
    • Operator performance in surgical telemanipulation
    • A. Kazi, "Operator performance in surgical telemanipulation, " Presence, vol. 10, pp. 495-510, 2001.
    • (2001) Presence , vol.10 , pp. 495-510
    • Kazi, A.1
  • 10
    • 0032861335 scopus 로고    scopus 로고
    • Force controlled and teleoperated endoscopic grasper for minimally invasive surgeryexperimental performance evaluation
    • J. Rosen, B. Hannaford, M. P. MacFarlane, and M. N. Sinanan, "Force controlled and teleoperated endoscopic grasper for minimally invasive surgeryexperimental performance evaluation, " IEEE Transactions on Biomedical Engineering, vol. 46, pp. 1212-21, 1999.
    • (1999) IEEE Transactions on Biomedical Engineering , vol.46 , pp. 1212-1221
    • Rosen, J.1    Hannaford, B.2    MacFarlane, M.P.3    Sinanan, M.N.4
  • 13
    • 0023154439 scopus 로고
    • Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip
    • R. S. Johansson and G. Westling, "Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip, " Exp Brain Res, vol. 66, pp. 141-54, 1987.
    • (1987) Exp Brain Res , vol.66 , pp. 141-154
    • Johansson, R.S.1    Westling, G.2
  • 15
    • 0002552326 scopus 로고
    • Sensing and manipulation problems in endoscopic surgery
    • F. Tendick, R. Jennings, G. Tharp, and L. Stark, "Sensing and Manipulation Problems in Endoscopic Surgery, " Presence, vol. 2, pp. 66-81, 1993.
    • (1993) Presence , vol.2 , pp. 66-81
    • Tendick, F.1    Jennings, R.2    Tharp, G.3    Stark, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.