메뉴 건너뛰기




Volumn 7, Issue , 2014, Pages 73-86

Flexible sensors for chronic wound management

Author keywords

BioFlex; biosensor; chronic wound; flexible; wound healing

Indexed keywords

BIOCOMPATIBILITY; BIOSENSORS;

EID: 84900388405     PISSN: 19373333     EISSN: 19411189     Source Type: Journal    
DOI: 10.1109/RBME.2013.2295817     Document Type: Article
Times cited : (78)

References (232)
  • 1
    • 58849124929 scopus 로고    scopus 로고
    • Areviewof gene and stem cell therapy in cutaneouswound healing
    • Mar.
    • L. K. Branski, G. G. Gauglitz, D. N. Herndon, and M. G. Jeschke, "Areviewof gene and stem cell therapy in cutaneouswound healing," Burns,vol. 35, no. 2, pp. 171-180, Mar. 2009.
    • (2009) Burns , vol.35 , Issue.2 , pp. 171-180
    • Branski, L.K.1    Gauglitz, G.G.2    Herndon, D.N.3    Jeschke, M.G.4
  • 2
    • 0033517356 scopus 로고    scopus 로고
    • Cutaneous wound healing
    • DOI 10.1056/NEJM199909023411006
    • A. J. Singer and R. A. F. Clark, "Cutaneous wound healing," N. Engl. J.Med., vol. 341, no. 10, pp. 738-746, 1999. (Pubitemid 29407375)
    • (1999) New England Journal of Medicine , vol.341 , Issue.10 , pp. 738-746
    • Singer, A.J.1    Clark, R.A.F.2
  • 3
    • 70350495204 scopus 로고    scopus 로고
    • Best treatment of nonhealing and problematic wounds
    • Aug.
    • E. Fogg, "Best treatment of nonhealing and problematic wounds," J.Amer. Acad. Physician Assist., vol. 22, no. 8, pp. 46-47, Aug. 2009.
    • (2009) J.Amer. Acad. Physician Assist. , vol.22 , Issue.8 , pp. 46-47
    • Fogg, E.1
  • 4
    • 0042627730 scopus 로고    scopus 로고
    • A review of mechanical adjuncts in wound healing: Hydrotherapy, ultrasound, negative pressure therapy, hyperbaric oxygen, and electrostimulation
    • DOI 10.1097/01.SAP.0000058513.10033.6B
    • C. L. Hess, M. A. Howard, and C. E. Attinger, "A review of mechanicaladjuncts in wound healing: Hydrotherapy, ultrasound, negative pressuretherapy, hyperbaric oxygen, and electrostimulation," Ann. Plast. Surg.,vol. 51, no. 2, pp. 210-218, Aug. 2003. (Pubitemid 36944492)
    • (2003) Annals of Plastic Surgery , vol.51 , Issue.2 , pp. 210-218
    • Hess, C.L.1    Howard, M.A.2    Attinger, C.E.3
  • 5
    • 0037132799 scopus 로고    scopus 로고
    • Science, medicine, and the future: Healing chronicwounds
    • Jan.
    • K. G. Harding, "Science, medicine, and the future: Healing chronicwounds," BMJ, vol. 324, no. 7330, pp. 160-163, Jan. 2002.
    • (2002) BMJ , vol.324 , Issue.7330 , pp. 160-163
    • Harding, K.G.1
  • 7
    • 20644472678 scopus 로고    scopus 로고
    • Electrical stimulation for wound healing: A review of evidence from in vitro studies, animal experiments, and clinical trials
    • DOI 10.1177/1534734605275733
    • L. C. Kloth, "Electrical stimulation for wound healing: A review ofevidence from in vitro studies, animal experiments, and clinical trials,"Int. J. Low. Extrem. Wounds, vol. 4, no. 1, pp. 23-44, Mar. 2005. (Pubitemid 41435504)
    • (2005) International Journal of Lower Extremity Wounds , vol.4 , Issue.1 , pp. 23-44
    • Kloth, L.C.1
  • 8
    • 0024993329 scopus 로고
    • Oxygen and wound healing
    • F. B. LaVan and T. K. Hunt, "Oxygen and wound healing," Clin. Plast.Surg., vol. 17, no. 3, pp. 463-472, Jul. 1990. (Pubitemid 20321238)
    • (1990) Clinics in Plastic Surgery , vol.17 , Issue.3 , pp. 463-472
    • La Van, F.B.1    Hunt, T.K.2
  • 9
    • 0030229887 scopus 로고    scopus 로고
    • Promotion of wound healing withelectrical stimulation
    • L. C. Kloth and J. M. McCulloch, "Promotion of wound healing withelectrical stimulation," Adv. Wound Care, vol. 9, no. 5, pp. 42-45.
    • Adv. Wound Care , vol.9 , Issue.5 , pp. 42-45
    • Kloth, L.C.1    McCulloch, J.M.2
  • 10
    • 0041733426 scopus 로고    scopus 로고
    • Electrical stimulation of wound healing
    • Jul.
    • J. C. Ojingwa and R. R. Isseroff, "Electrical stimulation of wound healing,"J. Invest. Dermatol., vol. 121, no. 1, pp. 1-12, Jul. 2003.
    • (2003) J. Invest. Dermatol. , vol.121 , Issue.1 , pp. 1-12
    • Ojingwa, J.C.1    Isseroff, R.R.2
  • 11
    • 37049097142 scopus 로고
    • Synthesis of electrically conducting organic polymers:Halogen derivatives of polyacetylene, (CH) x
    • H. Shirakawa, E. J. Louis, A. G. MacDiarmid, C. K. Chiang, andA. J. Heeger, "Synthesis of electrically conducting organic polymers:Halogen derivatives of polyacetylene, (CH) x," J. Chem. Soc. Chem.Commun., no. 16, pp. 578-580, 1977.
    • (1977) J. Chem. Soc. Chem.Commun. , vol.16 , pp. 578-580
    • Shirakawa, H.1    Louis, E.J.2    MacDiarmid, A.G.3    Chiang, C.K.4    Heeger, A.J.5
  • 13
    • 21544459113 scopus 로고
    • Organic electroluminescent diodes
    • C. W. Tang and S. A. VanSlyke, "Organic electroluminescent diodes,"Appl. Phys. Lett., vol. 51, no. 12, pp. 913-915, 1987.
    • (1987) Appl. Phys. Lett. , vol.51 , Issue.12 , pp. 913-915
    • Tang, C.W.1    Vanslyke, S.A.2
  • 14
    • 0032511040 scopus 로고    scopus 로고
    • Integrated optoelectronic devices based on conjugated polymers
    • DOI 10.1126/science.280.5370.1741
    • H. Sirringhaus, "Integrated optoelectronic devices based on conjugatedpolymers," Science, vol. 280, no. 5370, pp. 1741-1744, Jun. 1998. (Pubitemid 28283495)
    • (1998) Science , vol.280 , Issue.5370 , pp. 1741-1744
    • Sirringhaus, H.1    Tessler, N.2    Friend, R.H.3
  • 16
    • 0031947320 scopus 로고    scopus 로고
    • Soft lithography
    • Mar.
    • Y. Xia and G. M. Whitesides, "Soft Lithography," Angew. Chemie Int.Ed., vol. 37, no. 5, pp. 550-575, Mar. 1998.
    • (1998) Angew. Chemie Int.Ed. , vol.37 , Issue.5 , pp. 550-575
    • Xia, Y.1    Whitesides, G.M.2
  • 17
    • 0034615958 scopus 로고    scopus 로고
    • Monolithic microfabricated valves and pumps by multilayer soft lithography
    • DOI 10.1126/science.288.5463.113
    • M. A. Unger, H.-P. Chou, T. Thorsen, A. Scherer, and S. R. Quake,"Monolithic microfabricated valves and pumps by multilayer soft lithography,"Science, vol. 288, no. 5463, pp. 113-116, Apr. 2000. (Pubitemid 30203039)
    • (2000) Science , vol.288 , Issue.5463 , pp. 113-116
    • Unger, M.A.1    Chou, H.-P.2    Thorsen, T.3    Scherer, A.4    Quake, S.R.5
  • 18
    • 0037131390 scopus 로고    scopus 로고
    • Microfluidic large-scaleintegration
    • Oct.
    • T. Thorsen, S. J. Maerkl, and S. R. Quake, "Microfluidic large-scaleintegration," Science, vol. 298, no. 5593, pp. 580-584, Oct. 2002.
    • (2002) Science , vol.298 , Issue.5593 , pp. 580-584
    • Thorsen, T.1    Maerkl, S.J.2    Quake, S.R.3
  • 19
    • 0032403465 scopus 로고    scopus 로고
    • Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    • Dec.
    • D. C. Duffy, J. C. McDonald, O. J. A. Schueller, and G. M. Whitesides,"Rapid prototyping of microfluidic systems in poly(dimethylsiloxane),"Anal. Chem., vol. 70, no. 23, pp. 4974-4984, Dec. 1998.
    • (1998) Anal. Chem. , vol.70 , Issue.23 , pp. 4974-4984
    • Duffy, D.C.1    McDonald, J.C.2    Schueller, O.J.A.3    Whitesides, G.M.4
  • 20
    • 34250653329 scopus 로고    scopus 로고
    • Microsolidics: Fabrication of three-dimensional metallic microstructures in poly(dimethylsiloxane)
    • DOI 10.1002/adma.200601787
    • A. C. Siegel, D. A. Bruzewicz, D. B. Weibel, and G. M. Whitesides,"Microsolidics: Fabrication of three-dimensional metallic microstructuresin poly(dimethylsiloxane)," Adv. Mater., vol. 19, no. 5, pp. 727-733,Mar. 2007. (Pubitemid 46932842)
    • (2007) Advanced Materials , vol.19 , Issue.5 , pp. 727-733
    • Siegel, A.C.1    Bruzewicz, D.A.2    Weibel, D.B.3    Whitesides, G.M.4
  • 21
  • 23
    • 34748848799 scopus 로고    scopus 로고
    • Stretchable electrodes with high conductivity and photo-patternability
    • DOI 10.1002/adma.200601808
    • M. G. Urdaneta, R. Delille, and E. Smela, "Stretchable electrodes withhigh conductivity and photo-patternability," Adv. Mater., vol. 19, no. 18,pp. 2629-2633, Sep. 2007. (Pubitemid 47481826)
    • (2007) Advanced Materials , vol.19 , Issue.18 , pp. 2629-2633
    • Urdaneta, M.G.1    Delille, R.2    Smela, E.3
  • 27
    • 77950214388 scopus 로고    scopus 로고
    • Materials and mechanics forstretchable electronics
    • Mar.
    • J. A. Rogers, T. Someya, and Y. Huang, "Materials and mechanics forstretchable electronics," Science, vol. 327, no. 5973, pp. 1603-1607,Mar. 2010.
    • (2010) Science , vol.327 , Issue.5973 , pp. 1603-1607
    • Rogers, J.A.1    Someya, T.2    Huang, Y.3
  • 30
    • 0031613733 scopus 로고    scopus 로고
    • Wound management: A literature review
    • M. E. Lait and L. N. Smith, "Wound management: A literature review,"J. Clin. Nurs., vol. 7, no. 1, pp. 11-17, Jan. 1998. (Pubitemid 128705013)
    • (1998) Journal of Clinical Nursing , vol.7 , Issue.1 , pp. 11-17
    • Lait, M.E.1    Smith, L.N.2
  • 31
    • 0035114073 scopus 로고    scopus 로고
    • Moist wound healing with occlusive dressings: A clinical focus
    • DOI 10.1046/j.1524-4725.2001.00299.x
    • W. H. Eaglstein, "Moist wound healing with occlusive dressings: A clinicalfocus," Dermatol. Surg., vol. 27, no. 2, pp. 175-181, Mar. 2001. (Pubitemid 32167928)
    • (2001) Dermatologic Surgery , vol.27 , Issue.2 , pp. 175-181
    • Eaglstein, W.H.1
  • 33
    • 80053400855 scopus 로고    scopus 로고
    • Wound dressings: Principles and practice
    • Oct.
    • T. Abdelrahman and H. Newton, "Wound dressings: Principles and practice,"Surgery, vol. 29, no. 10, pp. 491-495, Oct. 2011.
    • (2011) Surgery , vol.29 , Issue.10 , pp. 491-495
    • Abdelrahman, T.1    Newton, H.2
  • 35
    • 47349117778 scopus 로고    scopus 로고
    • A systematicreview of silver-releasing dressings in the management of infectedchronic wounds
    • Aug.
    • S.-F. Lo, M. Hayter, C.-J. Chang, W.-Y. Hu, and L.-L. Lee, "A systematicreview of silver-releasing dressings in the management of infectedchronic wounds," J. Clin. Nurs., vol. 17, no. 15, pp. 1973-1985, Aug.2008.
    • (2008) J. Clin. Nurs. , vol.17 , Issue.15 , pp. 1973-1985
    • Lo, S.-F.1    Hayter, M.2    Chang, C.-J.3    Hu, W.-Y.4    Lee, L.-L.5
  • 36
    • 80052887806 scopus 로고    scopus 로고
    • Nanomedicine nanotechnology inmedicine
    • Sep.
    • P. Boisseau and B. Loubaton, "Nanomedicine, nanotechnology inmedicine," Comptes Rendus Phys., vol. 12, no. 7, pp. 620-636, Sep.2011.
    • (2011) Comptes Rendus Phys. , vol.12 , Issue.7 , pp. 620-636
    • Boisseau, P.1    Loubaton, B.2
  • 37
    • 84868214913 scopus 로고    scopus 로고
    • Polymeric microdevices fortransdermal and subcutaneous drug delivery
    • Nov.
    • M. Ochoa, C. Mousoulis, and B. Ziaie, "Polymeric microdevices fortransdermal and subcutaneous drug delivery," Adv. Drug Deliv. Rev.,vol. 64, no. 14, pp. 1603-1616, Nov. 2012.
    • (2012) Adv. Drug Deliv. Rev. , vol.64 , Issue.14 , pp. 1603-1616
    • Ochoa, M.1    Mousoulis, C.2    Ziaie, B.3
  • 38
    • 84900431839 scopus 로고    scopus 로고
    • Applicationsof modern sensors and wireless technology in effective wound management
    • Oct.
    • N. Mehmood, A. Hariz, R. Fitridge, and N. H. Voelcker, "Applicationsof modern sensors and wireless technology in effective wound management,"J. Biomed. Mater. Res. B, pp. 1-11, Oct. 2013.
    • J. Biomed. Mater. Res. B , vol.2013 , pp. 1-11
    • Mehmood, N.1    Hariz, A.2    Fitridge, R.3    Voelcker, N.H.4
  • 40
    • 0035178205 scopus 로고    scopus 로고
    • Cost and cost effectivenessof venous and pressure ulcer protocols of care
    • M. D. Kerstein, E. Gemmen, L. van Rijswijk, C. H. Lyder, T. Phillips,G. Xakellis, K. Golden, and C. Harrington, "Cost and cost effectivenessof venous and pressure ulcer protocols of care," Dis. Manag. Heal.Outcomes, vol. 9, no. 11, pp. 651-636, 2001.
    • (2001) Dis. Manag. Heal.Outcomes , vol.9 , Issue.11 , pp. 651-636
    • Kerstein, M.D.1    Gemmen, E.2    Van Rijswijk, L.3    Lyder, C.H.4
  • 41
    • 0023409624 scopus 로고
    • Anin vitro assessment of wound dressing conformability
    • Sep.
    • D. Queen, J. H. Evans, J. D.Gaylor, J. M. Courtney, andW. H. Reid, "Anin vitro assessment of wound dressing conformability," Biomaterials,vol. 8, no. 5, pp. 372-376, Sep. 1987.
    • (1987) Biomaterials , vol.8 , Issue.5 , pp. 372-376
    • Queen, D.1    Evans, J.H.2    Gaylor, J.D.3    Courtney, J.M.4    Reid, W.H.5
  • 43
    • 34548643276 scopus 로고    scopus 로고
    • A review of moisture-control dressings in wound care
    • Nov.
    • D. W. Brett, "A review of moisture-control dressings in wound care,"J. Wound, Ostomy Cont. Nurs., vol. 33, no. 6, pp. S3-S8, Nov. 2006.
    • (2006) J. Wound, Ostomy Cont. Nurs. , vol.33 , Issue.6
    • Brett, D.W.1
  • 45
    • 84857944649 scopus 로고    scopus 로고
    • Engineers are from PDMSland,biologists are from polystyrenia
    • Apr.
    • E. Berthier, E. W. K. Young, and D. Beebe, "Engineers are from PDMSland,biologists are from polystyrenia," Lab Chip, vol. 12, no. 7,pp. 1224-1237, Apr. 2012.
    • (2012) Lab Chip , vol.12 , Issue.7 , pp. 1224-1237
    • Berthier, E.1    Young, E.W.K.2    Beebe, D.3
  • 46
    • 84864237663 scopus 로고    scopus 로고
    • Rapid prototyping for biomedicalengineering: Current capabilities and challenges
    • Jan.
    • A. D. Lantada and P. L. Morgado, "Rapid prototyping for biomedicalengineering: Current capabilities and challenges," Annu. Rev. Biomed.Eng., vol. 14, pp. 73-96, Jan. 2012.
    • (2012) Annu. Rev. Biomed.Eng. , vol.14 , pp. 73-96
    • Lantada, A.D.1    Morgado, P.L.2
  • 49
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • DOI 10.1002/elps.200305584
    • S. K. Sia and G. M. Whitesides, "Microfluidic devices fabricated inpoly(dimethylsiloxane) for biological studies," Electrophoresis, vol. 24,no. 21, pp. 3563-3576, Nov. 2003. (Pubitemid 38089159)
    • (2003) Electrophoresis , vol.24 , Issue.21 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2
  • 51
    • 38049057110 scopus 로고    scopus 로고
    • A multiaxial stretchable interconnectusing liquid-alloy-filled elastomeric microchannels
    • H.-J. Kim, C. Son, and B. Ziaie, "A multiaxial stretchable interconnectusing liquid-alloy-filled elastomeric microchannels," Appl. Phys. Lett.,vol. 92, no. 1, pp. 011904-1-011904-3, 2008.
    • (2008) Appl. Phys. Lett. , vol.92 , Issue.1 , pp. 0119041-0119043
    • Kim, H.-J.1    Son, C.2    Ziaie, B.3
  • 52
    • 84900444035 scopus 로고    scopus 로고
    • Specialty Coating Systems [Online]. Available
    • Specialty Coating Systems. (2011). SCS Parylene properties [Online]. Available: http://scscoatings.com/docs/brochures/parylene-properties.pdf
    • (2011) SCS Parylene Properties
  • 53
    • 4344595818 scopus 로고    scopus 로고
    • Parylenemicromolding, a rapid andlow-cost fabricationmethod for parylenemicrochannel
    • Sep.
    • H. Noh,Y. Huang, and P. J.Hesketh, "Parylenemicromolding, a rapid andlow-cost fabricationmethod for parylenemicrochannel," Sens. ActuatorsB, Chem., vol. 102, no. 1, pp. 78-85, Sep. 2004.
    • (2004) Sens. ActuatorsB, Chem. , vol.102 , Issue.1 , pp. 78-85
    • Noh, H.1    Huang, Y.2    Hesketh, P.J.3
  • 54
    • 33744965618 scopus 로고    scopus 로고
    • Design, fabrication and characterizationof monolithic embedded parylene microchannels in siliconsubstrate
    • P. J. Chen, C. Y. Shih, and Y. C. Tai, "Design, fabrication and characterizationof monolithic embedded parylene microchannels in siliconsubstrate," Lab Chip, vol. 6, no. 6, pp. 803-810, 2006.
    • (2006) Lab Chip , vol.6 , Issue.6 , pp. 803-810
    • Chen, P.J.1    Shih, C.Y.2    Tai, Y.C.3
  • 55
    • 57649097199 scopus 로고    scopus 로고
    • Floating-disk parylenemicrovalves for self-pressure-regulating flowcontrols
    • P. J. Chen, D. C. Rodger, M. S. Humayun, and Y. C. Tai, "Floating-Disk ParyleneMicrovalves for Self-Pressure-Regulating FlowControls,"J. Microelectromech. Syst., vol. 17, no. 6. pp. 1352-1361, 2008.
    • (2008) J. Microelectromech. Syst. , vol.17 , Issue.6 , pp. 1352-1361
    • Chen, P.J.1    Rodger, D.C.2    Humayun, M.S.3    Tai, Y.C.4
  • 56
    • 77951882314 scopus 로고    scopus 로고
    • A lowpower, on demand electrothermal valve for wirelessdrug delivery applications
    • Jan.
    • P.-Y. Li, T. K. Givrad, R. Sheybani, D. P. Holschneider, J.-M. I. Maarek,and E.Meng, "A lowpower, on demand electrothermal valve for wirelessdrug delivery applications," Lab Chip, vol. 10, no. 1, pp. 101-110, Jan.2010.
    • (2010) Lab Chip , vol.10 , Issue.1 , pp. 101-110
    • Li, P.-Y.1    Givrad, T.K.2    Sheybani, R.3    Holschneider, D.P.4    Maarekand, J.-M.I.5    Meng, E.6
  • 57
    • 34147139992 scopus 로고    scopus 로고
    • Surface-micromachined parylene dual valves for on-chip unpowered microflow regulation
    • DOI 10.1109/JMEMS.2006.889534
    • P. Chen, D. C. Rodger, E. M. Meng, M. S. Humayun, and Y.-C. Tai,"Surface-micromachined parylene dual valves for on-chip unpoweredmicroflow regulation," J. Microelectromech. Syst., vol. 16, no. 2, pp.223-231, 2007. (Pubitemid 46564198)
    • (2007) Journal of Microelectromechanical Systems , vol.16 , Issue.2 , pp. 223-231
    • Chen, P.-J.1    Rodger, D.C.2    Meng, E.M.3    Humayun, M.S.4    Tai, Y.-C.5
  • 58
    • 78751705934 scopus 로고    scopus 로고
    • Flexible parylene-basedmicroelectrode arrays for high resolution EMGrecordings in freely movingsmall animals
    • Feb.
    • C. Metallo, R. D. White, and B. A. Trimmer, "Flexible parylene-basedmicroelectrode arrays for high resolution EMGrecordings in freely movingsmall animals," J. Neurosci. Methods, vol. 195, no. 2, pp. 176-184,Feb. 2011.
    • (2011) J. Neurosci. Methods , vol.195 , Issue.2 , pp. 176-184
    • Metallo, C.1    White, R.D.2    Trimmer, B.A.3
  • 59
    • 28744454887 scopus 로고    scopus 로고
    • Nanopowder molding method for creating implantable high-aspect-ratio electrodes on thin flexible substrates
    • DOI 10.1016/j.biomaterials.2005.10.030, PII S0142961205010045
    • Z. Hu, D. M. Zhou, R. Greenberg, and T. Thundat, "Nanopowder moldingmethod for creating implantable high-aspect-ratio electrodes on thinflexible substrates," Biomaterials, vol. 27, no. 9, pp. 2009-2017, Mar.2006. (Pubitemid 41759494)
    • (2006) Biomaterials , vol.27 , Issue.9 , pp. 2009-2017
    • Hu, Z.1    Zhou, D.M.2    Greenberg, R.3    Thundat, T.4
  • 63
    • 77957949842 scopus 로고    scopus 로고
    • Simultaneous recording of ECoG and intracortical neuronalactivity using a flexible multichannel electrode-mesh in visualcortex
    • Jan.
    • H. Toda, T. Suzuki, H. Sawahata, K. Majima, Y. Kamitani, andI. Hasegawa, "Simultaneous recording of ECoG and intracortical neuronalactivity using a flexible multichannel electrode-mesh in visualcortex," Neuroimage, vol. 54, no. 1, pp. 203-212, Jan. 2011.
    • (2011) Neuroimage , vol.54 , Issue.1 , pp. 203-212
    • Toda, H.1    Suzuki, T.2    Sawahata, H.3    Majima, K.4    Kamitani, Y.5    Hasegawa, I.6
  • 64
    • 84900425571 scopus 로고    scopus 로고
    • Thin-Film microelectrode arrays for biomedical applications
    • D. Zhou and E. Greenbaum,Eds. New York, NY, USA: Springer
    • K. C. Cheung, "Thin-Film microelectrode arrays for biomedical applications,"in Implantable Neural Prostheses 2, D. Zhou and E. Greenbaum,Eds. New York, NY, USA: Springer, 2010.
    • (2010) Implantable Neural Prostheses , pp. 2
    • Cheung, K.C.1
  • 66
    • 47649131551 scopus 로고    scopus 로고
    • Fabrication ofmicro sensors on aflexible substrate
    • Sep.
    • C.-Y. Lee, G.-W.Wu, andW.-J. Hsieh, "Fabrication ofmicro sensors on aflexible substrate," Sens. Actuators A, Phys., vol. 147, no. 1, pp. 173-176,Sep. 2008.
    • (2008) Sens. Actuators A, Phys. , vol.147 , Issue.1 , pp. 173-176
    • Lee, C.-Y.1    Wu, G.-W.2    Hsieh, W.-J.3
  • 68
    • 67849132111 scopus 로고    scopus 로고
    • AMEMS-based flexible multichannel ECoG-electrode array
    • Jun.
    • B. Rubehn, C. Bosman, R. Oostenveld, P. Fries, and T. Stieglitz, "AMEMS-based flexible multichannel ECoG-electrode array," J. NeuralEng., vol. 6, no. 3, p. 036003, Jun. 2009.
    • (2009) J. NeuralEng. , vol.6 , Issue.3 , pp. 036003
    • Rubehn, B.1    Bosman, C.2    Oostenveld, R.3    Fries, P.4    Stieglitz, T.5
  • 69
    • 48049086101 scopus 로고    scopus 로고
    • Characterizationof flexible ECoG electrode arrays for chronic recording in awakerats
    • Aug.
    • J. D. Yeager, D. J. Phillips, D. M. Rector, and D. F. Bahr, "Characterizationof flexible ECoG electrode arrays for chronic recording in awakerats," J. Neurosci. Methods, vol. 173, no. 2, pp. 279-285, Aug. 2008.
    • (2008) J. Neurosci. Methods , vol.173 , Issue.2 , pp. 279-285
    • Yeager, J.D.1    Phillips, D.J.2    Rector, D.M.3    Bahr, D.F.4
  • 71
    • 79959695192 scopus 로고    scopus 로고
    • A flexiblepH sensor based on the iridium oxide sensing film
    • Sep.
    • W.-D. Huang, H. Cao, S. Deb, M. Chiao, and J. C. Chiao, "A flexiblepH sensor based on the iridium oxide sensing film," Sens. Actuators A,Phys., vol. 169, no. 1, pp. 1-11, Sep. 2011.
    • (2011) Sens. Actuators A,Phys. , vol.169 , Issue.1 , pp. 1-11
    • Huang, W.-D.1    Cao, H.2    Deb, S.3    Chiao, M.4    Chiao, J.C.5
  • 72
    • 84876708632 scopus 로고    scopus 로고
    • Development of nanoparticle film-based multi-axial tactile sensors forbiomedical applications
    • Jul.
    • D. Alvares, L. Wieczorek, B. Raguse, F. Ladouceur, and N. H. Lovell,"Development of nanoparticle film-based multi-axial tactile sensors forbiomedical applications," Sens. Actuators A, Phys., vol. 196, pp. 38-47,Jul. 2013.
    • (2013) Sens. Actuators A, Phys. , vol.196 , pp. 38-47
    • Alvares, D.1    Wieczorek, L.2    Raguse, B.3    Ladouceur, F.4    Lovell, N.H.5
  • 73
    • 84875988822 scopus 로고    scopus 로고
    • A novel flexibleroom temperature ethanol gas sensor based on SnO2 doped polydiallyldimethylammoniumchloride
    • Jan.
    • S. Zhan, D. Li, S. Liang, X. Chen, and X. Li, "A novel flexibleroom temperature ethanol gas sensor based on SnO2 doped polydiallyldimethylammoniumchloride," Sens. (Basel), vol. 13, no. 4,pp. 4378-4389, Jan. 2013.
    • (2013) Sens. (Basel) , vol.13 , Issue.4 , pp. 4378-4389
    • Zhan, S.1    Li, D.2    Liang, S.3    Chen, X.4    Li, X.5
  • 75
    • 43249093667 scopus 로고    scopus 로고
    • The effect of glow discharge plasma on the surface properties of Poly (ethylene terephthalate) (PET) film
    • DOI 10.1016/j.surfcoat.2008.03.015, PII S0257897208001904
    • K. Pandiyaraj, V. Selvarajan, R. Deshmukh, and M. Bousmina, "The effectof glow discharge plasma on the surface properties of Poly (ethyleneterephthalate) (PET) film," Surf. Coatings Technol., vol. 202, no. 17,pp. 4218-4226, May 2008. (Pubitemid 351650218)
    • (2008) Surface and Coatings Technology , vol.202 , Issue.17 , pp. 4218-4226
    • Pandiyaraj, K.N.1    Selvarajan, V.2    Deshmukh, R.R.3    Bousmina, M.4
  • 77
    • 84868214913 scopus 로고    scopus 로고
    • Polymeric microdevices fortransdermal and subcutaneous drug delivery
    • Nov.
    • M. Ochoa, C. Mousoulis, and B. Ziaie, "Polymeric microdevices fortransdermal and subcutaneous drug delivery," Adv. Drug Deliv. Rev.,vol. 64, no. 14, pp. 1603-1616, Nov. 2012.
    • (2012) Adv. Drug Deliv. Rev. , vol.64 , Issue.14 , pp. 1603-1616
    • Ochoa, M.1    Mousoulis, C.2    Ziaie, B.3
  • 78
    • 0036678844 scopus 로고    scopus 로고
    • Soft, conformable electrical contacts fororganic semiconductors: High-resolution plastic circuits by lamination
    • Aug.
    • Y. Loo, T. Someya, K. W. Baldwin, Z. Bao, P. Ho, A. Dodabalapur,H. E. Katz, and J. A. Rogers, "Soft, conformable electrical contacts fororganic semiconductors: High-resolution plastic circuits by lamination,"PNAS, vol. 99, no. 16, pp. 10252-10256, Aug. 2002.
    • (2002) PNAS , vol.99 , Issue.16 , pp. 10252-10256
    • Loo, Y.1    Someya, T.2    Baldwin, K.W.3    Bao, Z.4    Ho, P.5    Dodabalapur, A.6    Katz, H.E.7    Rogers, J.A.8
  • 79
    • 77956430820 scopus 로고    scopus 로고
    • Roll-to-roll production of 30-inchgraphene films for transparent electrodes
    • Aug. Jun.
    • S. Bae, H. Kim, Y. Lee, X. Xu, J.-S. Park, Y. Zheng, J. Balakrishnan,T. Lei, H. Ri Kim, Y. Il Song, Y.-J. Kim, K. S. Kim, B. Ö zyilmaz,J.-H. Ahn, B. H. Hong, and S. Iijima, "Roll-to-roll production of 30-inchgraphene films for transparent electrodes," Nat. Nanotechnol., vol. 5,no. Aug., pp. 1-5, Jun. 2010.
    • (2010) Nat. Nanotechnol. , vol.5
    • Bae, S.1    Kim, H.2    Lee, Y.3    Xu, X.4    Park, J.-S.5    Zheng, Y.6
  • 81
    • 79952177518 scopus 로고    scopus 로고
    • Laser-treatedhydrophobic paper: An inexpensive microfluidic platform
    • Mar.
    • G. Chitnis, Z. Ding, C. Chang, C. A. Savran, and B. Ziaie, "Laser-treatedhydrophobic paper: An inexpensive microfluidic platform," Lab Chip,vol. 11, no. 6, pp. 1161-1165, Mar. 2011.
    • (2011) Lab Chip , vol.11 , Issue.6 , pp. 1161-1165
    • Chitnis, G.1    Ding, Z.2    Chang, C.3    Savran, C.A.4    Ziaie, B.5
  • 82
    • 84867471840 scopus 로고    scopus 로고
    • Waterproof active paper via laser surface micropatterningof magnetic nanoparticles
    • Sep.
    • G. Chitnis and B. Ziaie, "Waterproof active paper via laser surface micropatterningof magnetic nanoparticles," ACS Appl. Mater. Interfaces,vol. 4, no. 9, pp. 4435-4439, Sep. 2012.
    • (2012) ACS Appl. Mater. Interfaces , vol.4 , Issue.9 , pp. 4435-4439
    • Chitnis, G.1    Ziaie, B.2
  • 83
    • 33750275570 scopus 로고    scopus 로고
    • Polymers as biomaterials for tissue engineering and controlled drug delivery
    • DOI 10.1007/b137240, Tissue Engineering I
    • L. S. Nair and C. T. Laurencin, "Polymers as biomaterials for tissue engineeringand controlled drug delivery," Adv. Biochem. Eng. Biotechnol.,vol. 102, pp. 47-90, Jan. 2006. (Pubitemid 44608153)
    • (2006) Advances in Biochemical Engineering/Biotechnology , vol.102 , pp. 47-90
    • Nair, L.S.1    Laurencin, C.T.2
  • 84
    • 10644228534 scopus 로고    scopus 로고
    • Bioabsorbable implant material review
    • DOI 10.1053/j.otsm.2004.07.015, PII S1060187204000541
    • P. B. Maurus and C. C. Kaeding, "Bioabsorbable implant material review,"Oper. Tech. Sports Med., vol. 12, no. 3, pp. 158-160, Jul. 2004. (Pubitemid 39654753)
    • (2004) Operative Techniques in Sports Medicine , vol.12 , Issue.3 , pp. 158-160
    • Maurus, P.B.1    Kaeding, C.C.2
  • 86
    • 34247273993 scopus 로고    scopus 로고
    • Patterned paper as a platform for inexpensive, low-volume, portable bioassays
    • DOI 10.1002/anie.200603817
    • A. W. Martinez, S. T. Phillips, M. J. Butte, and G. M. Whitesides, "Patternedpaper as a platform for inexpensive, low-volume, portable bioassays,"Angew. Chem. Int. Ed. Engl., vol. 46, no. 8, pp. 1318-1320, Jan.2007. (Pubitemid 46981385)
    • (2007) Angewandte Chemie - International Edition , vol.46 , Issue.8 , pp. 1318-1320
    • Martinez, A.W.1    Phillips, S.T.2    Butte, M.J.3    Whitesides, G.M.4
  • 87
    • 77956328100 scopus 로고    scopus 로고
    • Programmable diagnostic devicesmade from paper and tape
    • Oct.
    • A. W. Martinez, S. T. Phillips, Z. Nie, C.-M. Cheng, E. Carrilho,B. J. Wiley, and G. M. Whitesides, "Programmable diagnostic devicesmade from paper and tape," Lab Chip, vol. 10, no. 19, pp. 2499-2504,Oct. 2010.
    • (2010) Lab Chip , vol.10 , Issue.19 , pp. 2499-2504
    • Martinez, A.W.1    Phillips, S.T.2    Nie, Z.3    Cheng, C.-M.4
  • 88
    • 79952312661 scopus 로고    scopus 로고
    • Microfluidics formedical diagnostics and biosensors
    • Apr.
    • C. Rivet, H. Lee, A. Hirsch, S. Hamilton, and H. Lu, "Microfluidics formedical diagnostics and biosensors," Chem. Eng. Sci., vol. 66, no. 7,pp. 1490-1507, Apr. 2011.
    • (2011) Chem. Eng. Sci. , vol.66 , Issue.7 , pp. 1490-1507
    • Rivet, C.1    Lee, H.2    Hirsch, A.3    Hamilton, S.4    Lu, H.5
  • 89
    • 0037144243 scopus 로고    scopus 로고
    • An all-organic sensor-transistor based on a novel electrochemical transducer concept printed electrochemical sensors on paper
    • DOI 10.1016/S0925-4005(02)00170-3, PII S0925400502001703
    • D. Nilsson, "An all-organic sensor-transistor based on a novel electrochemicaltransducer concept printed electrochemical sensors on paper,"Sens. Actuators B, Chem., vol. 86, pp. 193-197, Sep. 2002. (Pubitemid 35011392)
    • (2002) Sensors and Actuators, B: Chemical , vol.86 , Issue.2-3 , pp. 193-197
    • Nilsson, D.1    Kugler, T.2    Svensson, P.-O.3    Berggren, M.4
  • 90
    • 84878130967 scopus 로고    scopus 로고
    • CO2 laser cutting and ablative etching for the fabrication of paper-baseddevices
    • Jun.
    • P. Spicar-Mihalic, B. Toley, J. Houghtaling, T. Liang, P. Yager, and E. Fu,"CO2 laser cutting and ablative etching for the fabrication of paper-baseddevices," J. Micromech. Microeng., vol. 23, no. 6, p. 067003, Jun. 2013.
    • (2013) J. Micromech. Microeng. , vol.23 , Issue.6 , pp. 067003
    • Spicar-Mihalic, P.1    Toley, B.2    Houghtaling, J.3    Liang, T.4    Yager, P.5    Fu, E.6
  • 92
    • 80051681351 scopus 로고    scopus 로고
    • Pen-on-paper flexible electronics
    • Aug.
    • A. Russo, B. Y. Ahn, J. J. Adams, E. B. Duoss, J. T. Bernhard, andJ. A. Lewis, "Pen-on-paper flexible electronics," Adv. Mater., vol. 23,no. 30, pp. 3426-3430, Aug. 2011.
    • (2011) Adv. Mater. , vol.23 , Issue.30 , pp. 3426-3430
    • Russo, A.1    Ahn, B.Y.2    Adams, J.J.3    Duoss, E.B.4
  • 93
    • 17144404895 scopus 로고    scopus 로고
    • Health properties of resistant starch
    • DOI 10.1111/j.1467-3010.2005.00481.x
    • A. P. Nugent, "Health properties of resistant starch," Nutr. Bull., vol. 30,no. 1, pp. 27-54, Mar. 2005. (Pubitemid 40514552)
    • (2005) Nutrition Bulletin , vol.30 , Issue.1 , pp. 27-54
    • Nugent, A.P.1
  • 94
    • 0036206262 scopus 로고    scopus 로고
    • Starch-based biodegradable hydrogels with potential biomedical applications as drug delivery systems
    • DOI 10.1016/S0142-9612(01)00322-2, PII S0142961201003222
    • C. Elvira, J. F. Mano, J. San Roḿan, and R. L. Reis, "Starch-basedbiodegradable hydrogels with potential biomedical applications as drugdelivery systems," Biomaterials, vol. 23, no. 9, pp. 1955-1966, May2002. (Pubitemid 34251069)
    • (2002) Biomaterials , vol.23 , Issue.9 , pp. 1955-1966
    • Elvira, C.1    Mano, J.F.2    San Roman, J.3    Reis, R.L.4
  • 97
    • 84881479937 scopus 로고    scopus 로고
    • Stretchable nanoparticle conductors withself-organized conductive pathways
    • Aug.
    • Y. Kim, J. Zhu, B. Yeom, M. Di Prima, X. Su, J.-G. Kim, S. J. Yoo,C. Uher, and N. A. Kotov, "Stretchable nanoparticle conductors withself-organized conductive pathways," Nature, vol. 500, no. 7460, pp. 59-63, Aug. 2013.
    • (2013) Nature , vol.500 , Issue.7460 , pp. 59-63
    • Kim, Y.1    Zhu, J.2    Yeom, B.3    Di Prima, M.4    Su, X.5    Kim, J.-G.6    Yooc. Uher, S.J.7    Kotov, N.A.8
  • 98
    • 84884129394 scopus 로고    scopus 로고
    • Aflexible multifunctional sensor based on carbon nanotube/ polyurethanecomposite,"
    • IEEE Oct.
    • P. Slobodian, P. Riha, R. Benlikaya, P. Svoboda, and D. Petras, "Aflexible multifunctional sensor based on carbon nanotube/ polyurethanecomposite," IEEE Sens. J., vol. 13, no. 10, pp. 4045-4048, Oct.2013.
    • (2013) Sens. J. , vol.13 , Issue.10 , pp. 4045-4048
    • Slobodian, P.1    Riha, P.2    Benlikaya, R.3    Svoboda, P.4    Petras, D.5
  • 99
    • 84880080526 scopus 로고    scopus 로고
    • A resistive-type sensor based on flexiblemulti-walled carbon nanotubes and polyacrylic acid composite films
    • Sep.
    • J. Lee, D. Cho, and Y. Jeong, "A resistive-type sensor based on flexiblemulti-walled carbon nanotubes and polyacrylic acid composite films,"Solid State Electron., vol. 87, pp. 80-84, Sep. 2013.
    • (2013) Solid State Electron. , vol.87 , pp. 80-84
    • Lee, J.1    Cho, D.2    Jeong, Y.3
  • 100
    • 84879318834 scopus 로고    scopus 로고
    • Chemical sensing using electrospunpolymer/carbon nanotube composite nanofibers with printed-onelectrodes
    • Sep.
    • L. Han, A. L. Andrady, and D. S. Ensor, "Chemical sensing using electrospunpolymer/carbon nanotube composite nanofibers with printed-onelectrodes," Sens. Actuators B, Chem., vol. 186, pp. 52-55, Sep. 2013.
    • (2013) Sens. Actuators B, Chem. , vol.186 , pp. 52-55
    • Han, L.1    Andrady, A.L.2    Ensor, D.S.3
  • 101
    • 77951755595 scopus 로고    scopus 로고
    • Flexible temperature sensor array based on a graphitepolydimethylsiloxanecomposite
    • Jan.
    • W.-P. Shih, L.-C. Tsao, C.-W. Lee, M.-Y. Cheng, C. Chang, Y.-J. Yang,and K.-C. Fan, "Flexible temperature sensor array based on a graphitepolydimethylsiloxanecomposite," Sens. (Basel), vol. 10, no. 4, pp. 3597-3610, Jan. 2010.
    • (2010) Sens. (Basel) , vol.10 , Issue.4 , pp. 3597-3610
    • Shih, W.-P.1    Tsao, L.-C.2    Lee, C.-W.3    Cheng, M.-Y.4    Chang, C.5    Yangand, Y.-J.6    Fan, K.-C.7
  • 102
    • 79951510813 scopus 로고    scopus 로고
    • Flexible humidity and temperaturesensor based on cellulose-polypyrrole nanocomposite
    • Feb.
    • S. K. Mahadeva, S. Yun, and J. Kim, "Flexible humidity and temperaturesensor based on cellulose-polypyrrole nanocomposite," Sens. ActuatorsA, Phys., vol. 165, no. 2, pp. 194-199, Feb. 2011.
    • (2011) Sens. ActuatorsA, Phys. , vol.165 , Issue.2 , pp. 194-199
    • Mahadeva, S.K.1    Yun, S.2    Kim, J.3
  • 103
    • 40449133508 scopus 로고    scopus 로고
    • Composites of intrinsically conducting polymers as sensing nanomaterials
    • DOI 10.1021/cr068112h
    • D. W. Hatchett andM. Josowicz, "Composites of intrinsically conductingpolymers as sensing nanomaterials," Chem. Rev., vol. 108, no. 2, pp. 746-769, Feb. 2008. (Pubitemid 351350390)
    • (2008) Chemical Reviews , vol.108 , Issue.2 , pp. 746-769
    • Hatchett, D.W.1    Josowicz, M.2
  • 104
    • 1642452594 scopus 로고    scopus 로고
    • Hard and soft micromachining for BioMEMS: Review of techniques and examples of applications in microfluidics and drug delivery
    • DOI 10.1016/j.addr.2003.09.001
    • B. Ziaie, A. Baldi, M. Lei, Y. Gu, and R. A. Siegel, "Hard and softmicromachining for BioMEMS: Review of techniques and examples ofapplications in microfluidics and drug delivery," Adv. Drug Deliv. Rev.,vol. 56, no. 2, pp. 145-172, Feb. 2004. (Pubitemid 38114928)
    • (2004) Advanced Drug Delivery Reviews , vol.56 , Issue.2 , pp. 145-172
    • Ziaie, B.1    Baldi, A.2    Lei, M.3    Gu, Y.4    Siegel, R.A.5
  • 105
    • 0033876850 scopus 로고    scopus 로고
    • Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
    • DOI 10.1109/84.825780
    • B. H. Jo, L. M. Van Lerberghe, K. M. Motsegood, and D. J. Beebe,"Three-dimensional micro-channel fabrication in polydimethylsiloxane(PDMS) elastomer," J. Microelectromech. Syst., vol. 9, no. 1, pp. 76-81,2000. (Pubitemid 30581709)
    • (2000) Journal of Microelectromechanical Systems , vol.9 , Issue.1 , pp. 76-81
    • Jo, B.-H.1    Van Lerberghe, L.M.2    Motsegood, K.M.3    Beebe, D.J.4
  • 106
    • 41249087117 scopus 로고    scopus 로고
    • MEMS-based micropumps in drug delivery and biomedical applications
    • DOI 10.1016/j.snb.2007.10.064, PII S0925400507009148
    • A. Nisar, N. Afzulpurkar, B. Mahaisavariya, and A. Tuantranont, "MEMS-based micropumps in drug delivery and biomedical applications, "Sens. Actuators B, Chem., vol. 130, no. 2, pp. 917-942, Mar.2008. (Pubitemid 351444729)
    • (2008) Sensors and Actuators, B: Chemical , vol.130 , Issue.2 , pp. 917-942
    • Nisar, A.1    Afzulpurkar, N.2    Mahaisavariya, B.3    Tuantranont, A.4
  • 108
    • 77950917762 scopus 로고    scopus 로고
    • Functionalized superhydrophobic biomimetic chitosan-based films
    • May
    • W. Song, V. S. Gaware, Ö . V. Rúnarsson, M. Másson, and J. F. Mano,"Functionalized superhydrophobic biomimetic chitosan-based films,"Carbohydr. Polym., vol. 81, no. 1, pp. 140-144, May 2010.
    • (2010) Carbohydr. Polym. , vol.81 , Issue.1 , pp. 140-144
    • Song, W.1
  • 109
    • 77952616543 scopus 로고    scopus 로고
    • Lab-On-A-foil: Microfluidics on thin and flexible films
    • Jun.
    • M. Focke, D. Kosse, C. M̈uller, H. Reinecke, R. Zengerle, and F. vonStetten, "Lab-on-a-foil: Microfluidics on thin and flexible films," LabChip, vol. 10, no. 11, pp. 1365-1386, Jun. 2010.
    • (2010) LabChip , vol.10 , Issue.11 , pp. 1365-1386
    • Focke, M.1    Kosse, D.2    M̈uller, C.3    Reinecke, H.4    Zengerle, R.5    Vonstetten, F.6
  • 110
    • 84875763032 scopus 로고    scopus 로고
    • The third decade of microfluidics
    • A. Lee, "The third decade of microfluidics,". (2013). Lab Chip, vol. 13,no. 9, pp. 1660-1661, 2013.
    • (2013) Lab Chip , vol.13 , Issue.9 , pp. 1660-1661
    • Lee, A.1
  • 111
    • 58149378331 scopus 로고    scopus 로고
    • Threedimensionalmicrofluidic devices fabricated in layered paper and tape
    • Dec.
    • A. W. Martinez, S. T. Phillips, and G. M. Whitesides, "Threedimensionalmicrofluidic devices fabricated in layered paper and tape,"Proc. Natl. Acad. Sci. USA, vol. 105, no. 50, pp. 19606-19611, Dec.2008.
    • (2008) Proc. Natl. Acad. Sci. USA , vol.105 , Issue.50 , pp. 19606-19611
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3
  • 112
    • 34247273993 scopus 로고    scopus 로고
    • Patterned paper as a platform for inexpensive, low-volume, portable bioassays
    • DOI 10.1002/anie.200603817
    • A. W. Martinez, S. T. Phillips, M. J. Butte, and G. M. Whitesides, "Patternedpaper as a platform for inexpensive, low-volume, portable bioassays,"Angew. Chem. Int. Ed. Engl., vol. 46, no. 8, pp. 1318-1320, Jan.2007. (Pubitemid 46981385)
    • (2007) Angewandte Chemie - International Edition , vol.46 , Issue.8 , pp. 1318-1320
    • Martinez, A.W.1    Phillips, S.T.2    Butte, M.J.3    Whitesides, G.M.4
  • 113
    • 78049416195 scopus 로고    scopus 로고
    • A reliable method for bondingpolydimethylsiloxane (PDMS) to polymethylmethacrylate (PMMA) andits application in micropumps
    • Nov.
    • H. Y. Tan,W. K. Loke, and N.-T. Nguyen, "A reliable method for bondingpolydimethylsiloxane (PDMS) to polymethylmethacrylate (PMMA) andits application in micropumps," Sens. Actuators B Chem., vol. 151, no. 1,pp. 133-139, Nov. 2010.
    • (2010) Sens. Actuators B Chem. , vol.151 , Issue.1 , pp. 133-139
    • Tan, H.Y.1    Loke, W.K.2    Nguyen, N.-T.3
  • 114
    • 0042040751 scopus 로고    scopus 로고
    • 2-laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems
    • DOI 10.1039/b206409j
    • H. Klank, J. P.Kutter, and O. Geschke, "CO(2)-laser micromachining andback-end processing for rapid production of PMMA-based microfluidicsystems, " Lab Chip, vol. 2, no. 4, pp. 242-246, Nov. 2002. (Pubitemid 37254487)
    • (2002) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.2 , Issue.4 , pp. 242-246
    • Klank, H.1    Kutter, J.P.2    Geschke, O.3
  • 116
    • 80054966334 scopus 로고    scopus 로고
    • Rapid prototypingpolymers for microfluidic devices and high pressure injections
    • Nov.
    • E. Sollier, C. Murray, P. Maoddi, and D. Di Carlo, "Rapid prototypingpolymers for microfluidic devices and high pressure injections," LabChip, vol. 11, no. 22, pp. 3752-3765, Nov. 2011.
    • (2011) LabChip , vol.11 , Issue.22 , pp. 3752-3765
    • Sollier, E.1    Murray, C.2    Maoddi, P.3    Di Carlo, D.4
  • 118
    • 84908202398 scopus 로고
    • Plasma etching and modification of organic polymers
    • F. D. Egitto, "Plasma etching and modification of organic polymers,"Pure Appl. Chem, vol. 62, no. 9, pp. 1699-1708, 1990.
    • (1990) Pure Appl. Chem , vol.62 , Issue.9 , pp. 1699-1708
    • Egitto, F.D.1
  • 119
    • 11144236389 scopus 로고    scopus 로고
    • A BioMEMS review: MEMS technology for physiologically integrated devices
    • DOI 10.1109/JPROC.2003.820534, Biomedical Applications for Mems and Microfluidics
    • A. C. R. Grayson, R. S. Shawgo, A. M. Johnson, N. T. Flynn, Y. Li,M. J. Cima, and R. Langer, "A BioMEMS review: MEMS technologyfor physiologically integrated devices," Proc. IEEE, vol. 92, no. 1, pp. 6-21, Jan. 2004. (Pubitemid 40890769)
    • (2004) Proceedings of the IEEE , vol.92 , Issue.1 , pp. 6-21
    • Grayson, A.C.R.1    Shawgo, R.S.2    Johnson, A.M.3    Flynn, N.T.4    Li, Y.5    Cima, M.J.6    Langer, R.7
  • 120
    • 60449112624 scopus 로고    scopus 로고
    • A biaxial stretchable interconnect with liquidalloy-covered joints on elastomeric substrate
    • Feb.
    • T. Maleki and B. Ziaie, "A biaxial stretchable interconnect with liquidalloy-covered joints on elastomeric substrate," J. Microelectromech.Syst., vol. 18, no. 1, pp. 138-146, Feb. 2009.
    • (2009) J. Microelectromech.Syst. , vol.18 , Issue.1 , pp. 138-146
    • Maleki, T.1    Ziaie, B.2
  • 121
    • 77952402826 scopus 로고    scopus 로고
    • A novel approach to useof elastomer for monitoring of pressure using plastic optical fiber
    • Apr.
    • A. Kulkarni, H. Kim, J. Choi, and T. Kim, "A novel approach to useof elastomer for monitoring of pressure using plastic optical fiber," Rev.Sci. Instrum., vol. 81, no. 4, p. 045108, Apr. 2010.
    • (2010) Rev.Sci. Instrum. , vol.81 , Issue.4 , pp. 045108
    • Kulkarni, A.1    Kim, H.2    Choi, J.3    Kim, T.4
  • 122
    • 0036155610 scopus 로고    scopus 로고
    • A polydimethylsiloxane (PDMS) deformable diffraction grating for monitoring of local pressure in microfluidic devices
    • DOI 10.1088/0960-1317/12/1/301, PII S0960131702210578
    • K. Hosokawa, K. Hanada, and R. Maeda, "A polydimethylsiloxane(PDMS) deformable diffraction grating for monitoring of local pressurein microfluidic devices," J. Micromech. Microeng., vol. 12, no. 1,pp. 1-6, 2002. (Pubitemid 34090227)
    • (2002) Journal of Micromechanics and Microengineering , vol.12 , Issue.1 , pp. 1-6
    • Hosokawa, K.1    Hanada, K.2    Maeda, R.3
  • 123
    • 31944444177 scopus 로고    scopus 로고
    • Micro-actuators: When artificial muscles made of nematic liquid crystal elastomers meet soft lithography
    • DOI 10.1021/ja0575070
    • A. Buguin, M. Li, P. Silberzan, B. Ladoux, and P. Keller, "Micro-Actuators: When artificial muscles made of nematic liquid crystal elastomersmeet soft lithography," J. Am. Chem. Soc., vol. 128, no. 4, pp.1088-1089, 2006. (Pubitemid 43190616)
    • (2006) Journal of the American Chemical Society , vol.128 , Issue.4 , pp. 1088-1089
    • Buguin, A.1    Li, M.-H.2    Silberzan, P.3    Ladoux, B.4    Keller, P.5
  • 125
    • 55349131660 scopus 로고    scopus 로고
    • Performance characteristics of a polypyrrole modifiedpolydimethylsiloxane (PDMS) membrane based microfluidic pump
    • Nov.
    • J. H. Kim, K. T. Lau, R. Shepherd,Y.Wu, G.Wallace, D. Diamond, J. Ho,and K. Tong, "Performance characteristics of a polypyrrole modifiedpolydimethylsiloxane (PDMS) membrane based microfluidic pump,"Sens. Actuators A, Phys., vol. 148, no. 1, pp. 239-244, Nov. 2008.
    • (2008) Sens. Actuators A, Phys. , vol.148 , Issue.1 , pp. 239-244
    • Kim, J.H.1    Lau, K.T.2    Shepherd, R.3    Wu, Y.4    Wallace, G.5    Diamond, D.6    Hoand, J.7    Tong, K.8
  • 126
    • 79551696342 scopus 로고    scopus 로고
    • A batch-fabricated lasermicromachinedPDMS actuator with stamped carbon grease electrodes
    • Feb.
    • T. Maleki, G. Chitnis, and B. Ziaie, "A batch-fabricated lasermicromachinedPDMS actuator with stamped carbon grease electrodes,"J. Micromech. Microeng., vol. 21, no. 2, p. 027002, Feb. 2011.
    • (2011) J. Micromech. Microeng. , vol.21 , Issue.2 , pp. 027002
    • Maleki, T.1    Chitnis, G.2    Ziaie, B.3
  • 127
    • 75149182255 scopus 로고    scopus 로고
    • Low-cost rapid prototyping of flexiblemicrofluidic devices using a desktop digital craft cutter
    • Feb.
    • P. K. Yuen and V. N. Goral, "Low-cost rapid prototyping of flexiblemicrofluidic devices using a desktop digital craft cutter," Lab Chip,vol. 10, no. 3, pp. 384-387, Feb. 2010.
    • (2010) Lab Chip , vol.10 , Issue.3 , pp. 384-387
    • Yuen, P.K.1    Goral, V.N.2
  • 129
    • 84878160704 scopus 로고    scopus 로고
    • A low-cost rapid prototypingmethod for metal electrode fabrication using a CO2 laser cutter
    • Apr.
    • A. Toossi, M. Daneshmand, and D. Sameoto, "A low-cost rapid prototypingmethod for metal electrode fabrication using a CO2 laser cutter,"J. Micromech. Microeng., vol. 23, no. 4, p. 047001, Apr. 2013.
    • (2013) J. Micromech. Microeng. , vol.23 , Issue.4 , pp. 047001
    • Toossi, A.1    Daneshmand, M.2    Sameoto, D.3
  • 130
    • 0033878862 scopus 로고    scopus 로고
    • Laser ablation machining of metal/polymer composite materials
    • DOI 10.1016/S0169-4332(99)00391-8
    • A. Slocombe and L. Li, "Laser ablation machining of metal r polymercomposite materials," Appl. Surf. Sci., vol. 154-155, pp. 617-621, 2000. (Pubitemid 30573106)
    • (2000) Applied Surface Science , vol.154 , pp. 617-621
    • Slocombe, A.1    Li, L.2
  • 131
    • 79952177518 scopus 로고    scopus 로고
    • Lasertreatedhydrophobic paper: An inexpensive microfluidic platform
    • Mar.
    • G. Chitnis, Z. Ding, C.-L. Chang, C. A. Savran, and B. Ziaie, "Lasertreatedhydrophobic paper: An inexpensive microfluidic platform,"Lab Chip, vol. 11, no. 6, pp. 1161-1165, Mar. 2011.
    • (2011) Lab Chip , vol.11 , Issue.6 , pp. 1161-1165
    • Chitnis, G.1    Ding, Z.2    Chang, C.-L.3    Savran, C.A.4    Ziaie, B.5
  • 132
    • 77049107803 scopus 로고    scopus 로고
    • InkjetPrinting-Process and its applications
    • M. Singh, H. M. Haverinen, P. Dhagat, and G. E. Jabbour, "InkjetPrinting-Process and its applications," Adv. Mater., vol. 22, no. 6,pp. 673-685, 2010.
    • (2010) Adv. Mater. , vol.22 , Issue.6 , pp. 673-685
    • Singh, M.1    Haverinen, H.M.2    Dhagat, P.3    Jabbour, G.E.4
  • 136
    • 84866355664 scopus 로고    scopus 로고
    • Rapid casting of patterned vascular networksfor perfusable engineered three-dimensional tissues
    • Sep.
    • J. S. Miller, K. R. Stevens, M. T. Yang, B. M. Baker, D.-H. T. Nguyen,D. M. Cohen, E. Toro, A. A. Chen, P. A. Galie, X. Yu, R. Chaturvedi,S. N. Bhatia, and C. S. Chen, "Rapid casting of patterned vascular networksfor perfusable engineered three-dimensional tissues," Nat. Mater.,vol. 11, no. 9, pp. 768-774, Sep. 2012.
    • (2012) Nat. Mater. , vol.11 , Issue.9 , pp. 768-774
    • Miller, J.S.1    Stevens, K.R.2    Yang, M.T.3
  • 137
    • 84890048290 scopus 로고    scopus 로고
    • Three-dimensional drug printing:A structured review
    • 2013
    • I. D. Ursan, L. Chiu, and A. Pierce, "Three-dimensional drug printing:A structured review," J. Amer. Pharm. Assoc. (2003), vol. 53, no. 2,pp. 136-144, 2013.
    • (2003) J. Amer. Pharm. Assoc. , vol.53 , Issue.2 , pp. 136-144
    • Ursan, I.D.1    Chiu, L.2    Pierce, A.3
  • 138
    • 84862869528 scopus 로고    scopus 로고
    • A review of trends and limitations in hydrogel-rapid prototypingfor tissue engineering
    • Sep.
    • T. Billiet, M. Vandenhaute, J. Schelfhout, S. Van Vlierberghe, andP. Dubruel, "A review of trends and limitations in hydrogel-rapid prototypingfor tissue engineering," Biomaterials, vol. 33, no. 26, pp. 6020-6041, Sep. 2012.
    • (2012) Biomaterials , vol.33 , Issue.26 , pp. 6020-6041
    • Billiet, T.1    Vandenhaute, M.2    Schelfhout, J.3    Vlierberghe, S.V.4    Dubruel, P.5
  • 139
    • 33846450633 scopus 로고    scopus 로고
    • Influence of pH on wound-healing: A new perspective for wound-therapy?
    • DOI 10.1007/s00403-006-0713-x
    • L. A. Schneider, A. Korber, S. Grabbe, and J. Dissemond, "Influence ofpH on wound-healing: A new perspective for wound-therapy?"," Arch.Dermatol. Res., vol. 298, no. 9, pp. 413-20, Feb. 2007. (Pubitemid 46144202)
    • (2007) Archives of Dermatological Research , vol.298 , Issue.9 , pp. 413-420
    • Schneider, L.A.1    Korber, A.2    Grabbe, S.3    Dissemond, J.4
  • 142
    • 0027068213 scopus 로고
    • Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications
    • DOI 10.1016/0956-5663(92)85056-G
    • G. Urban, G. Jobst, F. Keplinger, E. Aschauer, O. Tilado, R. Fasching,and F. Kohl, "Miniaturized multi-enzyme biosensors integrated with pHsensors on flexible polymer carriers for in vivo applications," Biosens.Bioelectron., vol. 7, no. 10, pp. 733-739, Jan. 1992. (Pubitemid 23038819)
    • (1992) Biosensors and Bioelectronics , vol.7 , Issue.10 , pp. 733-739
    • Urban, G.1    Jobst, G.2    Keplinger, F.3    Aschauer, E.4    Tilado, O.5    Fasching, R.6    Kohl, F.7
  • 143
    • 0028531672 scopus 로고
    • A solid-state pH sensorbased on a Nafion-coated iridium oxide indicator electrode and apolymer-based silver chloride reference electrode
    • Oct.
    • P. J. Kinlen, J. E. Heider, and D. E. Hubbard, "A solid-state pH sensorbased on a Nafion-coated iridium oxide indicator electrode and apolymer-based silver chloride reference electrode," Sens. Actuators B,Chem., vol. 22, no. 1, pp. 13-25, Oct. 1994.
    • (1994) Sens. Actuators B,Chem. , vol.22 , Issue.1 , pp. 13-25
    • Kinlen, P.J.1    Heider, J.E.2    Hubbard, D.E.3
  • 145
    • 79959695192 scopus 로고    scopus 로고
    • A flexiblepH sensor based on the iridium oxide sensing film
    • Sep.
    • W.-D. Huang, H. Cao, S. Deb, M. Chiao, and J. C. Chiao, "A flexiblepH sensor based on the iridium oxide sensing film," Sens. Actuators A,Phys., vol. 169, no. 1, pp. 1-11, Sep. 2011.
    • (2011) Sens. Actuators A,Phys. , vol.169 , Issue.1 , pp. 1-11
    • Huang, W.-D.1    Cao, H.2    Deb, S.3    Chiao, M.4    Chiao, J.C.5
  • 146
    • 69249222622 scopus 로고    scopus 로고
    • Phosphoricacid and pHsensors based on polyaniline films
    • Jan.
    • M. M. Ayad, N. a. Salahuddin, M. O. Alghaysh, and R. M. Issa, "Phosphoricacid and pHsensors based on polyaniline films," Curr. Appl. Phys.,vol. 10, no. 1, pp. 235-240, Jan. 2010.
    • (2010) Curr. Appl. Phys. , vol.10 , Issue.1 , pp. 235-240
    • Ayad, M.M.1    Salahuddin, N.2    Alghaysh, M.O.3    Issa, R.M.4
  • 147
    • 84880949876 scopus 로고    scopus 로고
    • Printed composite electrodes for in-situ wound pH monitoring
    • Jul.
    • D. Sharp, "Printed composite electrodes for in-situ wound pH monitoring,"Biosens. Bioelectron., vol. 50 C, pp. 399-405, Jul. 2013.
    • (2013) Biosens. Bioelectron. , vol.50 C , pp. 399-405
    • Sharp, D.1
  • 148
    • 84883761135 scopus 로고    scopus 로고
    • Sol-Gel iridium oxide-based pH sensor array on flexiblepolyimide substrate
    • Oct.
    • C. M. Nguyen, W.-D. Huang, S. Rao, H. Cao, U. Tata, M. Chiao, andJ.-C. Chiao, "Sol-Gel iridium oxide-based pH sensor array on flexiblepolyimide substrate," IEEE Sens. J., vol. 13, no. 10, pp. 3857-3864, Oct.2013.
    • (2013) IEEE Sens. J. , vol.13 , Issue.10 , pp. 3857-3864
    • Nguyen, C.M.1    Huang, W.-D.2    Rao, S.3    Cao, H.4    Tata, U.5    Chiao, M.6    Chiao, J.-C.7
  • 149
    • 77953658901 scopus 로고    scopus 로고
    • Screenprinted electrochemical platforms for pHsensing
    • D. K. Kampouris, R. O. Kadara, N. Jenkinson, and C. E. Banks, "Screenprinted electrochemical platforms for pHsensing," Anal.Methods, vol. 1,no. 1, pp. 25-28, 2009.
    • (2009) Anal.Methods , vol.1 , Issue.1 , pp. 25-28
    • Kampouris, D.K.1    Kadara, R.O.2    Jenkinson, N.3    Banks, C.E.4
  • 150
    • 70349718271 scopus 로고    scopus 로고
    • Review paper:Materials and techniques for in vivo pH monitoring
    • O. Korostynska, K. Arshak, E. Gill, and A. Arshak, "Review paper:Materials and techniques for in vivo pH monitoring," IEEE Sens. J.,vol. 8, no. 1, pp. 20-28, 2008.
    • (2008) IEEE Sens. J. , vol.8 , Issue.1 , pp. 20-28
    • Korostynska, O.1    Arshak, K.2    Gill, E.3    Arshak, A.4
  • 151
    • 84900392115 scopus 로고    scopus 로고
    • An overview ofpH sensors based on iridium oxide: Fabrication and application
    • S. Kakooei, M. C. Ismail, and B. Ari-wahjoedi, "An overview ofpH sensors based on iridium oxide: Fabrication and application," Int.J. Mater. Sci. Innov., vol. 1, no. 1, pp. 62-72, 2013.
    • (2013) Int.J. Mater. Sci. Innov. , vol.1 , Issue.1 , pp. 62-72
    • Kakooei, S.1    Ismail, M.C.2    Ari-Wahjoedi, B.3
  • 152
    • 77953145049 scopus 로고    scopus 로고
    • Metal oxides and ion-exchanging surfaces as pH sensorsin liquids: State-Of-The-Art and outlook
    • P. Kurzweil, "Metal oxides and ion-exchanging surfaces as pH sensorsin liquids: State-of-the-art and outlook," Sensors, vol. 9, no. 6, pp. 4955-4985, 2009.
    • (2009) Sensors , vol.9 , Issue.6 , pp. 4955-4985
    • Kurzweil, P.1
  • 153
    • 33746033374 scopus 로고    scopus 로고
    • PH electrodesconstructed from polyaniline/zeolite and polypyrrole/zeolite conductiveblends
    • Aug.
    • P. Malkaj, E. Dalas, E. Vitoratos, and S. Sakkopoulos, "pH electrodesconstructed from polyaniline/zeolite and polypyrrole/zeolite conductiveblends," J. Appl. Polym. Sci., vol. 101, no. 3, pp. 1853-1856, Aug.2006.
    • (2006) J. Appl. Polym. Sci. , vol.101 , Issue.3 , pp. 1853-1856
    • Malkaj, P.1    Dalas, E.2    Vitoratos, E.3    Sakkopoulos, S.4
  • 154
    • 40849088341 scopus 로고    scopus 로고
    • Review on hydrogel-based pH sensors and microsensors
    • A. Richter, G. Paschew, S. Klatt, J. Lienig, K. Arndt, and H. P. Adler,"Review on hydrogel-based pH sensors and microsensors," Sensors,vol. 8, no. 1, pp. 561-581, 2008.
    • (2008) Sensors , vol.8 , Issue.1 , pp. 561-581
    • Richter, A.1    Paschew, G.2    Klatt, S.3    Lienig, J.4    Arndt, K.5    Adler, H.P.6
  • 155
    • 71749102388 scopus 로고    scopus 로고
    • A hydrogel-based passive wireless sensorusing a flex-circuit inductive transducer
    • Oct.
    • V. Sridhar and K. Takahata, "A hydrogel-based passive wireless sensorusing a flex-circuit inductive transducer," Sens. Actuators A, Phys.,vol. 155, no. 1, pp. 58-65, Oct. 2009.
    • (2009) Sens. Actuators A, Phys. , vol.155 , Issue.1 , pp. 58-65
    • Sridhar, V.1    Takahata, K.2
  • 156
    • 84859865117 scopus 로고    scopus 로고
    • Miniaturized textilebasedmulti-layer ph-sensor for wound monitoring applications
    • Jan.
    • A. Nocke, A. Schr̈oter, C. Cherif, and G. Gerlach, "Miniaturized textilebasedmulti-layer ph-sensor for wound monitoring applications," AutexRes. J., vol. 12, no. 1, pp. 20-22, Jan. 2012.
    • (2012) AutexRes. J. , vol.12 , Issue.1 , pp. 20-22
    • Nocke, A.1    Schr̈oter, A.2    Cherif, C.3    Gerlach, G.4
  • 158
    • 1642269211 scopus 로고    scopus 로고
    • Oxygen in Wound Healing - More than a Nutrient
    • DOI 10.1007/s00268-003-7400-2
    • A. A. Tandara and T. A. Mustoe, "Oxygen in wound healing-more thana nutrient," World J. Surg., vol. 28, no. 3, pp. 294-300, Mar. 2004. (Pubitemid 38375532)
    • (2004) World Journal of Surgery , vol.28 , Issue.3 , pp. 294-300
    • Tandara, A.A.1    Mustoe, T.A.2
  • 159
    • 16644399934 scopus 로고    scopus 로고
    • Hyperbaric oxygen therapy in extremity trauma
    • J. E. Greensmith, "Hyperbaric oxygen therapy in extremity trauma,"J. Amer. Acad. Orthop. Surg., vol. 12, no. 6, pp. 376-384.
    • J. Amer. Acad. Orthop. Surg. , vol.12 , Issue.6 , pp. 376-384
    • Greensmith, J.E.1
  • 160
    • 1642415178 scopus 로고    scopus 로고
    • Clinical hyperbaric oxygen therapy, wound perfusion, and transcutaneous oximetry
    • DOI 10.1007/s00268-003-7401-1
    • J. H. A. Niinikoski, "Clinical hyperbaric oxygen therapy, wound perfusion,and transcutaneous oximetry," World J. Surg., vol. 28, no. 3,pp. 307-311, Mar. 2004. (Pubitemid 38375534)
    • (2004) World Journal of Surgery , vol.28 , Issue.3 , pp. 307-311
    • Niinikoski, J.H.A.1
  • 161
    • 84878796540 scopus 로고    scopus 로고
    • An evaluation of the efficacy of transdermalcontinuous oxygen therapy in patients with recalcitrant diabetic footulcer
    • D. Kemp andM. Hermans, "An evaluation of the efficacy of transdermalcontinuous oxygen therapy in patients with recalcitrant diabetic footulcer," J. Diabet. Foot Complicat., vol. 3, no. 1, pp. 6-12, 2011.
    • (2011) J. Diabet. Foot Complicat. , vol.3 , Issue.1 , pp. 6-12
    • Kemp, D.1    Hermans, M.2
  • 166
    • 19744380575 scopus 로고    scopus 로고
    • A wearable oxygen sensor for transcutaneous blood gas monitoring at the conjunctiva
    • DOI 10.1016/j.snb.2004.12.099, PII S0925400505000535
    • S. Iguchi, K.Mitsubayashi, T. Uehara, and M. Ogawa, "A wearable oxygensensor for transcutaneous blood gas monitoring at the conjunctiva, "Sens. Actuators B, Chem., vol. 108, no. 1-2, pp. 733-737, Jul. 2005. (Pubitemid 40743767)
    • (2005) Sensors and Actuators, B: Chemical , vol.108 , Issue.1-2 SPEC. ISS. , pp. 733-737
    • Iguchi, S.1    Mitsubayashi, K.2    Uehara, T.3    Ogawa, M.4
  • 167
    • 84880171641 scopus 로고    scopus 로고
    • Enhanced performance of flexible ZnO nanowire basedroom-temperature oxygen sensors by piezotronic effect
    • Jul.
    • S. Niu, Y. Hu, X. Wen, Y. Zhou, F. Zhang, L. Lin, S. Wang, andZ. L. Wang, "Enhanced performance of flexible ZnO nanowire basedroom-temperature oxygen sensors by piezotronic effect," Adv. Mater.,vol. 25, no. 27, pp. 3701-3706, Jul. 2013.
    • (2013) Adv. Mater. , vol.25 , Issue.27 , pp. 3701-3706
    • Niu, S.1    Hu, Y.2    Wen, X.3    Zhou, Y.4    Zhang, F.5    Lin, L.6    Wang Andz. L Wang, S.7
  • 168
    • 0027941043 scopus 로고
    • Overview of wound healing in a moistenvironment
    • Jan.
    • C. K. Field and M. D. Kerstein, "Overview of wound healing in a moistenvironment," Amer. J. Surg., vol. 167, no. 1, pp. S2-S6, Jan. 1994.
    • (1994) Amer. J. Surg. , vol.167 , Issue.1
    • Field, C.K.1    Kerstein, M.D.2
  • 170
    • 78650981743 scopus 로고    scopus 로고
    • Moisture and wound healing (Int́er̂et d'unOnguent Chinois (MEBO) dans le Maintient Local de l'Humidit́e)"
    • B. S. Atiyeh, S. N. Hayek, "Moisture and wound healing (Int́er̂et d'unOnguent Chinois (MEBO) dans le Maintient Local de l'Humidit́e)," J.des Plaies et Cicatrisation, vol. 9, pp. 7-11, 2005.
    • (2005) J.Des Plaies et Cicatrisation , vol.9 , pp. 7-11
    • Atiyeh, B.S.1    Hayek, S.N.2
  • 171
    • 33947724621 scopus 로고    scopus 로고
    • The role of moisturebalance in wound healing
    • Jan.
    • D. Okan, K. Woo, E. A. Ayello, and G. Sibbald, "The role of moisturebalance in wound healing," Adv. SkinWound Care, vol. 20, no. 1, pp. 39-53, Jan. 2007.
    • (2007) Adv. SkinWound Care , vol.20 , Issue.1 , pp. 39-53
    • Okan, D.1    Woo, K.2    Ayello, E.A.3    Sibbald, G.4
  • 172
    • 79952488807 scopus 로고    scopus 로고
    • Fully transparent andflexible humidity sensors fabricated by layer-by-layer self-assembly ofthin film of poly(2-acrylamido-2-methylpropane sulfonate) and its saltcomplex
    • Mar.
    • P.-G. Su, W.-C. Li, J.-Y. Tseng, and C.-J. Ho, "Fully transparent andflexible humidity sensors fabricated by layer-by-layer self-assembly ofthin film of poly(2-acrylamido-2-methylpropane sulfonate) and its saltcomplex," Sens. Actuators B, Chem., vol. 153, no. 1, pp. 29-36, Mar.2011.
    • (2011) Sens. Actuators B, Chem. , vol.153 , Issue.1 , pp. 29-36
    • Su, P.-G.1    Li, W.-C.2    Tseng, J.-Y.3    Ho, C.-J.4
  • 174
    • 38949173539 scopus 로고    scopus 로고
    • 2 nanoparticles- polypyrrole-poly-[3-(methacrylamino)propyl] trimethyl ammonium chloride composite materials
    • DOI 10.1016/j.snb.2007.09.011, PII S0925400507006934
    • P.-G. Su and C.-P. Wang, "Flexible humidity sensor basedon TiO2 nanoparticles-polypyrrole-poly [3-(methacrylamino)propyl]trimethyl ammonium chloride composite materials," Sens. Actuators B,Chem., vol. 129, no. 2, pp. 538-543, Feb. 2008. (Pubitemid 351221261)
    • (2008) Sensors and Actuators, B: Chemical , vol.129 , Issue.2 , pp. 538-543
    • Su, P.-G.1    Wang, C.-P.2
  • 175
    • 84858701895 scopus 로고    scopus 로고
    • Electrical and sensing properties of a flexiblehumidity sensor made of polyamidoamine dendrimer-Au nanoparticles
    • Apr.
    • P.-G. Su and C.-C. Shiu, "Electrical and sensing properties of a flexiblehumidity sensor made of polyamidoamine dendrimer-Au nanoparticles, "Sens. Actuators B, Chem., vol. 165, no. 1, pp. 151-156, Apr.2012.
    • (2012) Sens. Actuators B, Chem. , vol.165 , Issue.1 , pp. 151-156
    • Su, P.-G.1    Shiu, C.-C.2
  • 176
    • 48349130893 scopus 로고    scopus 로고
    • Integrated temperature, humidityand gas sensors on flexible substrates for low-power applications
    • A. Oprea, N. B̂arsan, and U. Weimar, "Integrated temperature, humidityand gas sensors on flexible substrates for low-power applications,"in Proc. Sensors, 2007, 2007, pp. 158-161.
    • (2007) Proc. Sensors , vol.2007 , pp. 158-161
    • Oprea, A.1    B̂arsan, N.2    Weimar, U.3
  • 177
    • 84877766104 scopus 로고    scopus 로고
    • Preparation of flexible resistivemicro-humidity sensors and their humidity-sensing properties
    • Jul.
    • D.-I. Lim, J.-R. Cha, and M.-S. Gong, "Preparation of flexible resistivemicro-humidity sensors and their humidity-sensing properties," Sens.Actuators B, Chem., vol. 183, pp. 574-582, Jul. 2013.
    • (2013) Sens.Actuators B, Chem. , vol.183 , pp. 574-582
    • Lim, D.-I.1    Cha, J.-R.2    Gong, M.-S.3
  • 179
    • 34247602501 scopus 로고    scopus 로고
    • Novel flexible resistive-type humidity sensor
    • DOI 10.1016/j.snb.2006.11.015, PII S0925400506007635
    • P.-G. Su and C.-S.Wang, "Novel flexible resistive-type humidity sensor,"Sens. Actuators B, Chem., vol. 123, no. 2, pp. 1071-1076, May 2007. (Pubitemid 46678801)
    • (2007) Sensors and Actuators, B: Chemical , vol.123 , Issue.2 , pp. 1071-1076
    • Su, P.-G.1    Wang, C.-S.2
  • 180
    • 70350075811 scopus 로고    scopus 로고
    • Monitoringmoisture without disturbing the wound dressing
    • D. Mccoll, M. Macdougall, L. Watret, and P. Connolly, "Monitoringmoisture without disturbing the wound dressing," Wounds, UK, vol. 5,no. 3, pp. 2-6, 2009.
    • (2009) Wounds, UK , vol.5 , Issue.3 , pp. 2-6
    • McColl, D.1    MacDougall, M.2    Watret, L.3    Connolly, P.4
  • 183
    • 84855452001 scopus 로고    scopus 로고
    • A clinical investigation into the relationshipbetween increased periwound skin temperature and local woundinfection in patients with chronic leg ulcers
    • Aug.
    • M. Fierheller and R. G. Sibbald, "A clinical investigation into the relationshipbetween increased periwound skin temperature and local woundinfection in patients with chronic leg ulcers," Adv. Skin Wound Care,vol. 23, no. 8, pp. 369-379, Aug. 2010.
    • (2010) Adv. Skin Wound Care , vol.23 , Issue.8 , pp. 369-379
    • Fierheller, M.1    Sibbald, R.G.2
  • 184
    • 78049512144 scopus 로고    scopus 로고
    • Woundinflammatory index: A 'proof of concept' study to assess wound healingtrajectory
    • Jul.
    • M. Bharara, J. Schoess, A. Nouvong, and D. G. Armstrong, "Woundinflammatory index: A 'proof of concept' study to assess wound healingtrajectory," J. Diabetes Sci. Technol., vol. 4, no. 4, pp. 773-779, Jul.2010.
    • (2010) J. Diabetes Sci. Technol. , vol.4 , Issue.4 , pp. 773-779
    • Bharara, M.1    Schoess, J.2    Nouvong, A.3    Armstrong, D.G.4
  • 185
    • 0031017104 scopus 로고    scopus 로고
    • Infrared dermal thermometry for the high-risk diabeticfoot
    • Feb.
    • D. G. Armstrong, L. A. Lavery, P. J. Liswood, W. F. Todd, andJ. A. Tredwell, "Infrared dermal thermometry for the high-risk diabeticfoot," Phys. Ther., vol. 77, no. 2, pp. 169-175, Feb. 1997.
    • (1997) Phys. Ther. , vol.77 , Issue.2 , pp. 169-175
    • Armstrong, D.G.1    Lavery, L.A.2    Liswood, P.J.3    Todd, W.F.4    Tredwell, J.A.5
  • 186
    • 3142749615 scopus 로고    scopus 로고
    • A new fabricationprocess for a flexible skin with temperature sensor array and itsapplications
    • Apr.
    • L. Gwo-Bin, H. Fu-Chun, L. Chia-Yen, and M. Jiun-Jih, "A new fabricationprocess for a flexible skin with temperature sensor array and itsapplications," Acta Mech. Sin., vol. 20, no. 2, pp. 140-145, Apr. 2004.
    • (2004) Acta Mech. Sin. , vol.20 , Issue.2 , pp. 140-145
    • Gwo-Bin, L.1    Fu-Chun, H.2    Chia-Yen, L.3    Jiun-Jih, M.4
  • 187
    • 36949032337 scopus 로고    scopus 로고
    • Miniaturized flexible temperature sensor
    • DOI 10.1109/JMEMS.2007.908437
    • Y. Moser and M. A. M. Gijs, "Miniaturized flexible temperature sensor,"J. Microelectromech. Syst., vol. 16, no. 6, pp. 1349-1354, Dec. 2007. (Pubitemid 350239127)
    • (2007) Journal of Microelectromechanical Systems , vol.16 , Issue.6 , pp. 1349-1354
    • Moser, Y.1    Gijs, M.A.M.2
  • 188
    • 34147171421 scopus 로고    scopus 로고
    • A cost-effective flexible MEMS technique for temperature sensing
    • DOI 10.1016/j.mejo.2007.01.022, PII S0026269207000377
    • S. Xiao, L. Che, X. Li, and Y. Wang, "A cost-effective flexible MEMStechnique for temperature sensing," Microelectron. J., vol. 38, no. 3,pp. 360-364, Mar. 2007. (Pubitemid 46559979)
    • (2007) Microelectronics Journal , vol.38 , Issue.3 , pp. 360-364
    • Xiao, S.1    Che, L.F.2    Li, X.3    Wang, Y.4
  • 190
    • 77957989896 scopus 로고    scopus 로고
    • Flexible temperature sensorson fibers
    • Jan.
    • M. Sibinski, M. Jakubowska, and M. Sloma, "Flexible temperature sensorson fibers," Sens. (Basel), vol. 10, no. 9, pp. 7934-7946, Jan. 2010.
    • (2010) Sens. (Basel) , vol.10 , Issue.9 , pp. 7934-7946
    • Sibinski, M.1    Jakubowska, M.2    Sloma, M.3
  • 191
    • 81155123663 scopus 로고    scopus 로고
    • A review ofthe role of mechanical forces in cutaneous wound healing
    • Dec.
    • R. Agha, R. Ogawa, G. Pietramaggiori, and D. P. Orgill, "A review ofthe role of mechanical forces in cutaneous wound healing," J. Surg. Res.,vol. 171, no. 2, pp. 700-708, Dec. 2011.
    • (2011) J. Surg. Res. , vol.171 , Issue.2 , pp. 700-708
    • Agha, R.1    Ogawa, R.2    Pietramaggiori, G.3    Orgill, D.P.4
  • 192
    • 0023852604 scopus 로고
    • The effect of mechanical stress on soft and hard tissue repair; A review
    • J. D. Urschel, P. G. Scott, and H. T.Williams, "The effect of mechanicalstress on soft and hard tissue repair: A review,"Br. J. Plast. Surg., vol. 41,no. 2, pp. 182-186, Mar. 1988. (Pubitemid 18068360)
    • (1988) British Journal of Plastic Surgery , vol.41 , Issue.2 , pp. 182-186
    • Urschel, J.D.1    Scott, P.G.2    Williams, H.T.G.3
  • 193
    • 0025936186 scopus 로고
    • Theeffect of mechanical stress on healing skin wounds: An experimentalstudy in rabbits using tissue expansion
    • Oct.
    • E. J. Timmenga,T. T. Andreassen, H. J. Houthoff, and P. J.Klopper, "Theeffect of mechanical stress on healing skin wounds: An experimentalstudy in rabbits using tissue expansion,"Br. J. Plast. Surg., vol. 44, no. 7,pp. 514-519, Oct. 1991.
    • (1991) Br. J. Plast. Surg. , vol.44 , Issue.7 , pp. 514-519
    • Timmengat, T.1    Andreassen, E.J.2    Houthoff, H.J.3    Klopper, P.J.4
  • 194
    • 84877656391 scopus 로고    scopus 로고
    • Flexible PZT thin film tactilesensor for biomedical monitoring
    • Jan.
    • H.-J. Tseng, W.-C. Tian, and W.-J. Wu, "Flexible PZT thin film tactilesensor for biomedical monitoring," Sens. (Basel), vol. 13, no. 5, pp. 5478-5492, Jan. 2013.
    • (2013) Sens. (Basel) , vol.13 , Issue.5 , pp. 5478-5492
    • Tseng, H.-J.1    Tian, W.-C.2    Wu, W.-J.3
  • 195
    • 64649083401 scopus 로고    scopus 로고
    • Flexible dome and bump shapepiezoelectric tactile sensors using PVDF-TrFE copolymer
    • Apr.
    • A. Gorton, M. J. Schulz, and C. H. Ahn, "Flexible dome and bump shapepiezoelectric tactile sensors using PVDF-TrFE copolymer," J. Microelectromech.Syst., vol. 17, no. 2, pp. 334-341, Apr. 2008.
    • (2008) J. Microelectromech.Syst. , vol.17 , Issue.2 , pp. 334-341
    • Gorton, A.1    Schulz, M.J.2    Ahn, C.H.3
  • 196
    • 79952534082 scopus 로고    scopus 로고
    • The developmentof a highly twistable tactile sensing array with stretchable helical electrodes
    • Apr.
    • M.-Y. Cheng, C.-M. Tsao, Y.-Z. Lai, and Y.-J. Yang, "The developmentof a highly twistable tactile sensing array with stretchable helical electrodes,"Sens. Actuators A, Phys., vol. 166, no. 2, pp. 226-233, Apr.2011.
    • (2011) Sens. Actuators A, Phys. , vol.166 , Issue.2 , pp. 226-233
    • Cheng, M.-Y.1    Tsao, C.-M.2    Lai, Y.-Z.3    Yang, Y.-J.4
  • 197
    • 84860383259 scopus 로고    scopus 로고
    • Flexible microfluidicnormal force sensor skin for tactile feedback
    • Jun.
    • R. D. PonceWong, J. D. Posner, and V. J. Santos, "Flexible microfluidicnormal force sensor skin for tactile feedback," Sens. Actuators A, Phys.,vol. 179, pp. 62-69, Jun. 2012.
    • (2012) Sens. Actuators A, Phys. , vol.179 , pp. 62-69
    • Poncewong, R.D.1    Posner, J.D.2    Santos, V.J.3
  • 198
    • 84860367849 scopus 로고    scopus 로고
    • A review of tactilesensing technologies with applications in biomedical engineering
    • Jun.
    • M. I. Tiwana, S. J. Redmond, and N. H. Lovell, "A review of tactilesensing technologies with applications in biomedical engineering," Sens.Actuators A, Phys., vol. 179, pp. 17-31, Jun. 2012.
    • (2012) Sens.Actuators A, Phys. , vol.179 , pp. 17-31
    • Tiwana, M.I.1    Redmond, S.J.2    Lovell, N.H.3
  • 199
    • 79955925136 scopus 로고    scopus 로고
    • Tactile sensing for dexterousin-hand manipulation in robotics-A review
    • Jun.
    • H.Yousef,M. Boukallel, andK.Althoefer, "Tactile sensing for dexterousin-hand manipulation in robotics-A review," Sens. Actuators A, Phys.,vol. 167, no. 2, pp. 171-187, Jun. 2011.
    • (2011) Sens. Actuators A, Phys. , vol.167 , Issue.2 , pp. 171-187
    • Yousef, H.1    Boukallel, M.2    Althoefer, K.3
  • 200
    • 84870313772 scopus 로고    scopus 로고
    • Roll-to-Roll fabricationof large area functional organic materials
    • Jan.
    • R. R. Søndergaard, M. Ḧosel, and F. C. Krebs, "Roll-to-Roll fabricationof large area functional organic materials," J. Polym. Sci. Part B Polym.Phys., vol. 51, no. 1, pp. 16-34, Jan. 2013.
    • (2013) J. Polym. Sci. Part B Polym.Phys. , vol.51 , Issue.1 , pp. 16-34
    • Søndergaard, R.R.1    Ḧosel, M.2    Krebs, F.C.3
  • 201
    • 84872103465 scopus 로고    scopus 로고
    • High-rate, roll-to-roll nanomanufacturingof flexible systems
    • Oct.
    • K. P. Cooper and R. F.Wachter, "High-rate, roll-to-roll nanomanufacturingof flexible systems," in Proc. SPIE, Oct. 2012, vol. 8466, no. 202,pp. 846602-1-846602-7.
    • (2012) Proc. SPIE , vol.8466 , Issue.202 , pp. 8466021-8466027
    • Cooper, K.P.1    Wachter, R.F.2
  • 202
    • 23744435844 scopus 로고    scopus 로고
    • Flexible electronics and displays: High-resolution, roll-to-roll, projection lithography and photoablation processing technologies for high-throughput production
    • DOI 10.1109/JPROC.2005.851505
    • K. Jain,M. Klosner,M. Zemel, and S. Raghunandan, "Flexible electronicsand displays: High-Resolution, roll-to-roll, projection lithography andphotoablation processing technologies for high-throughput production,"Proc. IEEE, vol. 93, no. 8, pp. 1500-1510, Aug. 2005. (Pubitemid 41118782)
    • (2005) Proceedings of the IEEE , vol.93 , Issue.8 , pp. 1500-1510
    • Jain, K.1    Klosner, M.2    Zemel, M.3    Raghunandan, S.4
  • 203
    • 84900447133 scopus 로고    scopus 로고
    • Johnson & Johnson Inc. [Online]. Available
    • Johnson & Johnson Inc. (2013). Gauze pads. [Online]. Available: http://www.jnjredcross.com/first-aid-cover-gauze
    • (2013) Gauze Pads
  • 204
    • 84900461995 scopus 로고    scopus 로고
    • 3M [Online]. Available
    • 3M. (2013). 3MT M TegadermT M Transparent Film Roll 16002. [Online]. Available: http://solutions.3 m.com/wps/portal/3M/en-US/3MSWC/Skin-Wound-Care/ ProductDirectory/NewCatalog/?N=42949-25477&rt=d
    • (2013) 3MT M TegadermT M Transparent Film Roll 16002
  • 205
    • 84900411796 scopus 로고    scopus 로고
    • 3M [Online].Available
    • 3M. (2013). 3MT M TegadermT M Hydrocolloid Dressing. [Online].Available: http://solutions.3 m.com/wps/portal/3M/en-US/3MSWC/Skin-Wound-Care/ ProductDirectory/NewCatalog/?/All-3M-Products/Industry-and-Professionals/ Medical-Supplies-Software/Critical-Chronic-Care?N =6219+4294929281&rt=d
    • (2013) 3MT M TegadermT M Hydrocolloid Dressing
  • 206
    • 84900421228 scopus 로고    scopus 로고
    • ConvaTec Inc. [Online].Available:
    • ConvaTec Inc. (2013). Convatec Aquacell Foam Dressing. [Online].Available: http://ep.yimg.com/ay/yhst-128880362216497/convatecaquacel- foam-dressings-all-sizes-1.jpg
    • (2013) Convatec Aquacell Foam Dressing
  • 207
    • 84900418284 scopus 로고    scopus 로고
    • ALGICELL Ag. [Online]. Available
    • Derma Sciences Inc. (2013). ALGICELL Ag. [Online]. Available:http://www. wondbedekkers.nl/spring-medical/algicell-ag.jpg
    • (2013) Derma Sciences Inc.
  • 208
    • 84900450757 scopus 로고    scopus 로고
    • M̈olnlycke Health Care Inc. [Online]. Available ala/ALA289100-HRE01. JPG
    • M̈olnlycke Health Care Inc. (2013). Mepitel OneWith Soft Silicone Technology. [Online]. Available: http://www.medline.com/media/catalog/sku/ala/ ALA289100-HRE01.JPG
    • (2013) Mepitel OneWith Soft Silicone Technology
  • 210
    • 84900438136 scopus 로고    scopus 로고
    • Universal Laser Systems Inc. [Online].Available
    • Universal Laser Systems, Inc. (2013). PLS6MW Platform. [Online].Available: http://www.ulsinc.com/downloads/spec-sheets/PLS6MW-platform. pdf
    • (2013) PLS6MW Platform
  • 211
    • 84884607395 scopus 로고    scopus 로고
    • Stratasys Ltd. [Online]. Available
    • Stratasys Ltd. (2013). 3D Printers. [Online]. Available: http://www.stratasys.com/3d-printers/
    • (2013) 3D Printers
  • 212
    • 0346846662 scopus 로고    scopus 로고
    • Biocompatibility of polyimide microelectrode array for retinal stimulation
    • DOI 10.1016/j.msec.2003.09.019
    • J.-M. Seo, S. J. Kim, H. Chung, E. T. Kim, H. G. Yu, and Y. S. Yu, "Biocompatibilityof polyimide microelectrode array for retinal stimulation,"Mater. Sci. Eng. C, vol. 24, no. 1-2, pp. 185-189, Jan. 2004. (Pubitemid 38005747)
    • (2004) Materials Science and Engineering C , vol.24 , Issue.1-2 , pp. 185-189
    • Seo, J.-M.1    Kim, S.J.2    Chung, H.3    Kim, E.T.4    Yu, H.G.5    Yu, Y.S.6
  • 213
    • 0016332605 scopus 로고
    • Gaseous transfer coefficientsin membranes
    • Dec.
    • S. T. Hwang, C. K. Choi, and K. Kammermeyer, "Gaseous transfer coefficientsin membranes," Sep. Sci., vol. 9, no. 6, pp. 461-478, Dec.1974.
    • (1974) Sep. Sci. , vol.9 , Issue.6 , pp. 461-478
    • Hwang, S.T.1    Choi, C.K.2    Kammermeyer, K.3
  • 217
    • 78650509587 scopus 로고    scopus 로고
    • Filter paper with selective absorption andseparation of liquids that differ in surface tension
    • Mar.
    • S. Wang, M. Li, and Q. Lu, "Filter paper with selective absorption andseparation of liquids that differ in surface tension," ACS Appl. Mater.Interfaces, vol. 2, no. 3, pp. 677-683, Mar. 2010.
    • (2010) ACS Appl. Mater.Interfaces , vol.2 , Issue.3 , pp. 677-683
    • Wang, S.1    Li, M.2    Lu, Q.3
  • 218
    • 0002659636 scopus 로고
    • Model for the moisture quenching of solidmatrixphosphorescence via the Young's modulus of filter paper
    • Jan.
    • J. Chen and R. J. Hurtubise, "Model for the moisture quenching of solidmatrixphosphorescence via the Young's modulus of filter paper," Appl.Spectrosc., vol. 49, no. 1, pp. 98-104, Jan. 1995.
    • (1995) Appl.Spectrosc. , vol.49 , Issue.1 , pp. 98-104
    • Chen, J.1    Hurtubise, R.J.2
  • 219
    • 84866981245 scopus 로고    scopus 로고
    • Recent advancesin paper-based sensors
    • Jan.
    • D. D. Liana, B. Raguse, J. J. Gooding, and E. Chow, "Recent advancesin paper-based sensors," Sens. (Basel), vol. 12, no. 9, pp. 11505-11526,Jan. 2012.
    • (2012) Sens. (Basel) , vol.12 , Issue.9 , pp. 11505-11526
    • Liana, D.D.1    Raguse, B.2    Gooding, J.J.3    Chow, E.4
  • 220
    • 0031126418 scopus 로고    scopus 로고
    • Water vapor permeability of biodegradable polymers
    • R. Shogren, "Water vapor permeability of biodegradable polymers,"J. Environ. Polym. Degrad., vol. 5, no. 2, pp. 91-95, Apr. 1997. (Pubitemid 27450025)
    • (1997) Journal of Environmental Polymer Degradation , vol.5 , Issue.2 , pp. 91-95
    • Shogren, R.1
  • 221
    • 0025844005 scopus 로고
    • Glass transition temperature of copolyesters of PET, PEN and PHB as determined by dynamic mechanical analysis
    • DOI 10.1016/0032-3861(91)90396-Z
    • D. Chen and H. G. Zachmann, "Glass transition temperature ofcopolyesters of PET, PEN and PHB as determined by dynamic mechanicalanalysis, " Polymer (Guildf), vol. 32, no. 9, pp. 1612-1621, Jan.1991. (Pubitemid 21683312)
    • (1991) Polymer , vol.32 , Issue.9 , pp. 1612-1621
    • Chen, D.1    Zachmann, H.G.2
  • 222
    • 0030540991 scopus 로고    scopus 로고
    • Long-term in vivo performance and biocompatibility of poly(vinyl alcohol) hydrogel macrocapsules for hybrid-type artificial pancreas
    • DOI 10.1016/S0142-9612(96)00076-2, PII S0142961296000762
    • K. Burczak, E. Gamian, and A. Kochman, "Long-term in vivo performanceand biocompatibility of poly(vinyl alcohol) hydrogel macrocapsulesfor hybrid-type artificial pancreas," Biomaterials, vol. 17, no. 24,pp. 2351-2356, Jan. 1996. (Pubitemid 26421740)
    • (1996) Biomaterials , vol.17 , Issue.24 , pp. 2351-2356
    • Burczak, K.1    Gamian, E.2    Kochman, A.3
  • 223
    • 80055080501 scopus 로고    scopus 로고
    • Mechanical characterizations of castPoly(3,4-ethylenedioxythiophene): Poly(styrenesulfonate)/polyvinyl alcoholthin films
    • Nov.
    • C. Chen, A. Torrents, L. Kulinsky, R. D. Nelson, M. J. Madou,L. Valdevit, and J. C. LaRue, "Mechanical characterizations of castPoly(3,4- ethylenedioxythiophene):Poly(styrenesulfonate)/polyvinyl alcoholthin films," Synth. Met., vol. 161, no. 21-22, pp. 2259-2267, Nov.2011.
    • (2011) Synth. Met. , vol.161 , Issue.21-22 , pp. 2259-2267
    • Chen, C.1    Torrents, A.2    Kulinsky, L.3    Nelson, R.D.4    Madou, M.J.5    Valdevit, L.6    Larue, J.C.7
  • 224
    • 8744254433 scopus 로고    scopus 로고
    • A literature review of poly(lactic acid)
    • D. Garlotta, "A literature reviewof poly (lactic acid)," J. Polym. Environ.,vol. 9, no. 2, pp. 63-84, 2001. (Pubitemid 33818548)
    • (2001) Journal of Polymers and the Environment , vol.9 , Issue.2 , pp. 63-84
    • Garlotta, D.1
  • 226
    • 77957002693 scopus 로고    scopus 로고
    • Inkjet printing of functional and structural materials: Fluidproperty requirements, feature stability, and resolution
    • Jun.
    • B. Derby, "Inkjet printing of functional and structural materials: Fluidproperty requirements, feature stability, and resolution," Annu. Rev.Mater. Res., vol. 40, no. 1, pp. 395-414, Jun. 2010.
    • (2010) Annu. Rev.Mater. Res. , vol.40 , Issue.1 , pp. 395-414
    • Derby, B.1
  • 227
    • 0034773430 scopus 로고    scopus 로고
    • Inkjet printing for materials and devices
    • DOI 10.1021/cm0101632
    • P. Calvert, "Inkjet printing for materials and devices," Chem. Mater.,vol. 13, no. 10, pp. 3299-3305, Oct. 2001. (Pubitemid 32999277)
    • (2001) Chemistry of Materials , vol.13 , Issue.10 , pp. 3299-3305
    • Calvert, P.1
  • 228
    • 84865202010 scopus 로고    scopus 로고
    • Configurable3D-printed millifluidic and microfluidic 'lab on a chip' reactionwaredevices
    • Sep.
    • P. J. Kitson, M. H. Rosnes, V. Sans, V. Dragone, and L. Cronin, "Configurable3D-printed millifluidic and microfluidic 'lab on a chip' reactionwaredevices," Lab Chip, vol. 12, no. 18, pp. 3267-3271, Sep. 2012.
    • (2012) Lab Chip , vol.12 , Issue.18 , pp. 3267-3271
    • Kitson, P.J.1    Rosnes, M.H.2    Sans, V.3    Dragone, V.4    Cronin, L.5
  • 229
    • 54249141877 scopus 로고    scopus 로고
    • The significance of surface pH in chronic wounds
    • G. Gethin, "The significance of surface pH in chronic wounds," WoundsUK, vol. 3, no. 3, pp. 52-55, 2007.
    • (2007) WoundsUK , vol.3 , Issue.3 , pp. 52-55
    • Gethin, G.1
  • 230
    • 58649103319 scopus 로고    scopus 로고
    • Wound healing essentials: Let there be oxygen
    • C. K. Sen, "Wound healing essentials: Let there be oxygen," WoundRepair Regen., vol. 17, no. 1, pp. 1-18, 2010.
    • (2010) WoundRepair Regen. , vol.17 , Issue.1 , pp. 1-18
    • Sen, C.K.1
  • 231
    • 35148889325 scopus 로고    scopus 로고
    • Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study
    • DOI 10.1016/j.ijsu.2007.02.008, PII S1743919107000350
    • D. McColl, B. Cartlidge, and P. Connolly, "Real-time monitoring ofmoisture levels in wound dressings in vitro: An experimental study," Int.J. Surg., vol. 5, no. 5, pp. 316-322, Oct. 2007. (Pubitemid 47539997)
    • (2007) International Journal of Surgery , vol.5 , Issue.5 , pp. 316-322
    • McColl, D.1    Cartlidge, B.2    Connolly, P.3
  • 232
    • 0029239625 scopus 로고
    • In vitroassessment of water vapour transmission of synthetic wound dressings
    • Jan.
    • P. Wu, A. C. Fisher, P. P. Foo, D. Queen, and J. D. S. Gaylor, "In vitroassessment of water vapour transmission of synthetic wound dressings,"Biomaterials, vol. 16, no. 3, pp. 171-175, Jan. 1995.
    • (1995) Biomaterials , vol.16 , Issue.3 , pp. 171-175
    • Wu, P.1    Fisher, A.C.2    Foo, P.P.3    Queen, D.4    Gaylor, J.D.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.