메뉴 건너뛰기




Volumn 174, Issue 1, 2012, Pages 96-102

A 3D printed dry electrode for ECG/EEG recording

Author keywords

3D printed dry electrode; Bioelectric signal recording; Electrocardiogram (ECG); Electroencephalogram (EEG)

Indexed keywords

3-D PRINTING; 3D PRINTERS; ADHESION PROMOTION; AG/AGCL; BIOELECTRIC SIGNALS; CAPABLE DESIGN; DRY ELECTRODE; ELECTROCARDIOGRAM (ECG); ELECTRODE CHARACTERIZATION; ELECTRODE MODELS; ELECTROENCEPHALOGRAM (EEG); HIGH PRECISION; LOW COSTS; MASS PRODUCTION; METALLIZATION PROCESS; WHOLE PROCESS;

EID: 84855880072     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2011.12.017     Document Type: Article
Times cited : (205)

References (17)
  • 1
    • 0034048104 scopus 로고    scopus 로고
    • A direct comparison of wet, dry and insulating bioelectric recording electrodes
    • DOI 10.1088/0967-3334/21/2/307, PII S0967333400090511
    • A. Searle, and L. Kirkup A direct comparison of wet, dry and insulating bioelectric recording electrodes Physiol. Meas. 21 2000 271 283 (Pubitemid 30353435)
    • (2000) Physiological Measurement , vol.21 , Issue.2 , pp. 271-283
    • Searle, A.1    Kirkup, L.2
  • 6
    • 41549116003 scopus 로고    scopus 로고
    • Flexible polymeric dry electrodes for the long-term monitoring of ECG
    • J.Y. Baek, J.H. An, J.M. Chio, K.S. Park, and S.H. Lee Flexible polymeric dry electrodes for the long-term monitoring of ECG Sens. Actuators A 143 2008 423 429
    • (2008) Sens. Actuators A , vol.143 , pp. 423-429
    • Baek, J.Y.1    An, J.H.2    Chio, J.M.3    Park, K.S.4    Lee, S.H.5
  • 10
    • 19944387297 scopus 로고    scopus 로고
    • Friction and wear studies of human hair and skin
    • DOI 10.1016/j.wear.2004.12.026, PII S0043164804004533, 15th International Conference on Wear of Materials
    • B. Bhushan, G. Wei, and P. Haddad Friction and wear studies of human hair and skin Wear 259 2005 1012 1021 (Pubitemid 40758990)
    • (2005) Wear , vol.259 , Issue.7-12 , pp. 1012-1021
    • Bhushan, B.1    Wei, G.2    Haddad, P.3
  • 11
  • 14
    • 0035109061 scopus 로고    scopus 로고
    • Scalp electrode impedance, infection risk, and EEG data quality
    • DOI 10.1016/S1388-2457(00)00533-2, PII S1388245700005332
    • T.C. Ferree, P. Luu, G.S. Russell, and D.M. Tucker Scalp electrode impedance, infection risk, and EEG data quality Clin. Neurophysiol. 112 2001 536 544 (Pubitemid 32166936)
    • (2001) Clinical Neurophysiology , vol.112 , Issue.3 , pp. 536-544
    • Ferree, T.C.1    Luu, P.2    Russell, G.S.3    Tucker, D.M.4
  • 17
    • 15944382768 scopus 로고    scopus 로고
    • Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
    • DOI 10.1016/j.clinph.2004.10.001
    • P. Tallgren, S. Vanhataloa, K. Kailaa, and J. Voipio Evaluation of commercially available electrodes and gels for recording of slow EEG potentials Clin. Neurophysiol. 116 2005 799 806 (Pubitemid 40431997)
    • (2005) Clinical Neurophysiology , vol.116 , Issue.4 , pp. 799-806
    • Tallgren, P.1    Vanhatalo, S.2    Kaila, K.3    Voipio, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.