-
1
-
-
33747622101
-
Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion
-
Bjornsson C.S., Oh S.J., Al-Kofahi Y.A., Lim Y.J., Smith K.L., Turner J.N., et al. Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion. J Neural Eng 3 (2006) 196-207
-
(2006)
J Neural Eng
, vol.3
, pp. 196-207
-
-
Bjornsson, C.S.1
Oh, S.J.2
Al-Kofahi, Y.A.3
Lim, Y.J.4
Smith, K.L.5
Turner, J.N.6
-
2
-
-
33846585141
-
Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
-
Cheung K.C., Renaud P., Tanila H., and Djupsund K. Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. Biosens Bioelectron 22 (2007) 1783-1790
-
(2007)
Biosens Bioelectron
, vol.22
, pp. 1783-1790
-
-
Cheung, K.C.1
Renaud, P.2
Tanila, H.3
Djupsund, K.4
-
3
-
-
0032148208
-
Adhesion and debonding of multi-layer thin film structures
-
Dauskardt R.H., Lane M., Ma Q., and Krishna N. Adhesion and debonding of multi-layer thin film structures. Eng Fract Mech 61 (1998) 141-162
-
(1998)
Eng Fract Mech
, vol.61
, pp. 141-162
-
-
Dauskardt, R.H.1
Lane, M.2
Ma, Q.3
Krishna, N.4
-
4
-
-
0014445808
-
Adhesion mechanism of gold-underlayer film combinations to oxide substrates
-
Haq K.E., Behrndt K.H., and Kobin I. Adhesion mechanism of gold-underlayer film combinations to oxide substrates. J Vac Sci Technol A 6 (1969) 148-152
-
(1969)
J Vac Sci Technol A
, vol.6
, pp. 148-152
-
-
Haq, K.E.1
Behrndt, K.H.2
Kobin, I.3
-
5
-
-
0025413793
-
Flexible miniature cables for long-term connection to implantable sensors
-
Hetke J.F., Najafi K., and Wise K.D. Flexible miniature cables for long-term connection to implantable sensors. Sens Actuators A21-A23 (1990) 999-1002
-
(1990)
Sens Actuators
, vol.A21-A23
, pp. 999-1002
-
-
Hetke, J.F.1
Najafi, K.2
Wise, K.D.3
-
6
-
-
33646147137
-
A MEMS fabricated flexible electrode array for recording surface field potentials
-
Hollenberg B.A., Richards C.D., Richards R., Bahr D.F., and Rector D.M. A MEMS fabricated flexible electrode array for recording surface field potentials. J Neurosci Methods 153 1 (2006) 147-153
-
(2006)
J Neurosci Methods
, vol.153
, Issue.1
, pp. 147-153
-
-
Hollenberg, B.A.1
Richards, C.D.2
Richards, R.3
Bahr, D.F.4
Rector, D.M.5
-
7
-
-
23844447327
-
Initiation and arrest of an interfacial crack in a four-point bend test
-
Huang Z., Suo Z., Xu G., He J., Prévost J.H., and Sukumar N. Initiation and arrest of an interfacial crack in a four-point bend test. Eng Fract Mech 72 (2005) 2584-2601
-
(2005)
Eng Fract Mech
, vol.72
, pp. 2584-2601
-
-
Huang, Z.1
Suo, Z.2
Xu, G.3
He, J.4
Prévost, J.H.5
Sukumar, N.6
-
8
-
-
0142153732
-
Four-point bend adhesion measurements of copper and permalloy systems
-
Hughey M.P., Morris D.J., Cook R.F., Bozeman S.P., Kelly B.L., Chakravarty S., et al. Four-point bend adhesion measurements of copper and permalloy systems. Eng Fract Mech 71 (2004) 245-261
-
(2004)
Eng Fract Mech
, vol.71
, pp. 245-261
-
-
Hughey, M.P.1
Morris, D.J.2
Cook, R.F.3
Bozeman, S.P.4
Kelly, B.L.5
Chakravarty, S.6
-
9
-
-
0036641732
-
The effect of sputtered interface metallic layers on reinforced core laminate making build-up structures
-
Jalonen P., and Tuominen A. The effect of sputtered interface metallic layers on reinforced core laminate making build-up structures. Microelectron Reliab 42 (2002) 1075-1079
-
(2002)
Microelectron Reliab
, vol.42
, pp. 1075-1079
-
-
Jalonen, P.1
Tuominen, A.2
-
10
-
-
0032821985
-
Spatiotemporal organization of fast (>200 Hz) electrical oscillations in rat vibrissa/barrel cortex
-
Jones M.S., and Barth D.S. Spatiotemporal organization of fast (>200 Hz) electrical oscillations in rat vibrissa/barrel cortex. J Neurophysiol 82 3 (1999) 1599-1609
-
(1999)
J Neurophysiol
, vol.82
, Issue.3
, pp. 1599-1609
-
-
Jones, M.S.1
Barth, D.S.2
-
11
-
-
0033812509
-
Intracellular correlates of fast (>200 Hz) electrical oscillations in rat somatosensory cortex
-
Jones M.S., MacDonald K.D., Choi B., Dudek F.E., and Barth D.S. Intracellular correlates of fast (>200 Hz) electrical oscillations in rat somatosensory cortex. J Neurophysiol 84 3 (2000) 1505-1518
-
(2000)
J Neurophysiol
, vol.84
, Issue.3
, pp. 1505-1518
-
-
Jones, M.S.1
MacDonald, K.D.2
Choi, B.3
Dudek, F.E.4
Barth, D.S.5
-
12
-
-
34247095495
-
Switchable polymer-based thin film coils as a power module for wireless neural interfaces
-
Kim S., Zoschke K., Klein M., Black D., Buschick K., Toepper M., et al. Switchable polymer-based thin film coils as a power module for wireless neural interfaces. Sens Actuators A: Phys 136 1 (2007) 467-474
-
(2007)
Sens Actuators A: Phys
, vol.136
, Issue.1
, pp. 467-474
-
-
Kim, S.1
Zoschke, K.2
Klein, M.3
Black, D.4
Buschick, K.5
Toepper, M.6
-
13
-
-
0345085514
-
The delamination of polymeric coatings from steel. Part 2: First stage of delamination, effect of type and concentration of cations on delamination, chemical analysis of the interface
-
Leng A., Streckel H., and Stratmann M. The delamination of polymeric coatings from steel. Part 2: First stage of delamination, effect of type and concentration of cations on delamination, chemical analysis of the interface. Corros Sci 41 (1999) 579-597
-
(1999)
Corros Sci
, vol.41
, pp. 579-597
-
-
Leng, A.1
Streckel, H.2
Stratmann, M.3
-
14
-
-
0345603127
-
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
-
Lawrence S.M., Dhillon G.S., and Horch K.W. Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode. J Neurosci Methods 131 (2003) 9-26
-
(2003)
J Neurosci Methods
, vol.131
, pp. 9-26
-
-
Lawrence, S.M.1
Dhillon, G.S.2
Horch, K.W.3
-
15
-
-
2042530135
-
Thin film platinum cuff electrodes for neurostimulation: in vitro approach of safe neurostimulation parameters
-
Mailley S., Hyland M., Mailley P., McLaughlin J.A., and McAdams E.T. Thin film platinum cuff electrodes for neurostimulation: in vitro approach of safe neurostimulation parameters. Bioelectrochemistry 63 (2004) 359-364
-
(2004)
Bioelectrochemistry
, vol.63
, pp. 359-364
-
-
Mailley, S.1
Hyland, M.2
Mailley, P.3
McLaughlin, J.A.4
McAdams, E.T.5
-
16
-
-
0035372012
-
Biocompatability and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium
-
Matsuno H., Yokoyama A., Watari F., Uo M., and Kawasaki T. Biocompatability and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials 22 (2001) 1253-1262
-
(2001)
Biomaterials
, vol.22
, pp. 1253-1262
-
-
Matsuno, H.1
Yokoyama, A.2
Watari, F.3
Uo, M.4
Kawasaki, T.5
-
17
-
-
0034655830
-
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
-
Maynard E.M., Fernandez E., and Normann R.A. A technique to prevent dural adhesions to chronically implanted microelectrode arrays. J Neurosci Methods 97 (2000) 93-101
-
(2000)
J Neurosci Methods
, vol.97
, pp. 93-101
-
-
Maynard, E.M.1
Fernandez, E.2
Normann, R.A.3
-
18
-
-
12344323809
-
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
-
Merrill D.R., Bikson M., and Jefferys J.G.R. Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods 141 (2005) 171-198
-
(2005)
J Neurosci Methods
, vol.141
, pp. 171-198
-
-
Merrill, D.R.1
Bikson, M.2
Jefferys, J.G.R.3
-
19
-
-
0030382632
-
Effect of oxygen plasma etching on adhesion between polyimide films and metal
-
Nakamura Y., Suzuki Y., and Watanabe Y. Effect of oxygen plasma etching on adhesion between polyimide films and metal. Thin Solid Films 290-291 (1996) 367-369
-
(1996)
Thin Solid Films
, vol.290-291
, pp. 367-369
-
-
Nakamura, Y.1
Suzuki, Y.2
Watanabe, Y.3
-
20
-
-
77949362605
-
Somatic motor and sensory representation in the cerebral cortex of man as studied by electrical stimulation
-
Penfield W., and Boldrey E. Somatic motor and sensory representation in the cerebral cortex of man as studied by electrical stimulation. Brain 60 (1937) 389-443
-
(1937)
Brain
, vol.60
, pp. 389-443
-
-
Penfield, W.1
Boldrey, E.2
-
21
-
-
26444445003
-
Response of brain tissue to chronically implanted neural electrode
-
Polikov V.S., Tresco P.A., and Reichert W.M. Response of brain tissue to chronically implanted neural electrode. J Neurosci Methods 148 (2005) 1-18
-
(2005)
J Neurosci Methods
, vol.148
, pp. 1-18
-
-
Polikov, V.S.1
Tresco, P.A.2
Reichert, W.M.3
-
22
-
-
0343915102
-
Diffusion at the polymer coating/metal interface
-
Pommersheim J., Nguyen T., Zhang Z., Lin C., and Cation. Diffusion at the polymer coating/metal interface. J Adhes Sci Technol 9 7 (1995) 935-951
-
(1995)
J Adhes Sci Technol
, vol.9
, Issue.7
, pp. 935-951
-
-
Pommersheim, J.1
Nguyen, T.2
Zhang, Z.3
Lin, C.4
Cation5
-
23
-
-
0036955568
-
Texture discrimination and unit recordings in the rat whisker/barrel system
-
Prigg T., Goldreich D., Carvell G.E., and Simons D.J. Texture discrimination and unit recordings in the rat whisker/barrel system. Physiol Behav 77 (2002) 671-675
-
(2002)
Physiol Behav
, vol.77
, pp. 671-675
-
-
Prigg, T.1
Goldreich, D.2
Carvell, G.E.3
Simons, D.J.4
-
24
-
-
0035713302
-
Continuous image and electrophysiological recording with real time processing and control
-
Rector D.M., and George J.S. Continuous image and electrophysiological recording with real time processing and control. Methods 25 2 (2001) 151-163
-
(2001)
Methods
, vol.25
, Issue.2
, pp. 151-163
-
-
Rector, D.M.1
George, J.S.2
-
25
-
-
0027703631
-
Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue
-
Schmidt S., Horch K., and Normann R. Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue. J Biomed Mater Res 27 11 (1993) 1393-1399
-
(1993)
J Biomed Mater Res
, vol.27
, Issue.11
, pp. 1393-1399
-
-
Schmidt, S.1
Horch, K.2
Normann, R.3
-
26
-
-
14744288765
-
Electrotherapy of tumour cells using fl{ligature}exible electrode arrays
-
Soden D., Morrissey A., Collins C., Piggott J., Larkin J., Norman A., et al. Electrotherapy of tumour cells using fl{ligature}exible electrode arrays. Sens Actuators B 103 (2004) 219-224
-
(2004)
Sens Actuators B
, vol.103
, pp. 219-224
-
-
Soden, D.1
Morrissey, A.2
Collins, C.3
Piggott, J.4
Larkin, J.5
Norman, A.6
-
27
-
-
0033163778
-
Implantable microsystems: polyimide-based neuroprostheses for interfacing nerves
-
Stieglitz T., and Meyer J.U. Implantable microsystems: polyimide-based neuroprostheses for interfacing nerves. Med Device Technol 10 6 (1999) 28-30
-
(1999)
Med Device Technol
, vol.10
, Issue.6
, pp. 28-30
-
-
Stieglitz, T.1
Meyer, J.U.2
-
28
-
-
0036015967
-
A biohybrid system to interface peripheral nerves after traumatic lesions: design of a high channel sieve electrode
-
Stieglitz T., Ruf H.H., Gross M., Schuettler M., and Meyer J.U. A biohybrid system to interface peripheral nerves after traumatic lesions: design of a high channel sieve electrode. Biosen Bioelectron 17 (2002) 685-696
-
(2002)
Biosen Bioelectron
, vol.17
, pp. 685-696
-
-
Stieglitz, T.1
Ruf, H.H.2
Gross, M.3
Schuettler, M.4
Meyer, J.U.5
-
29
-
-
0003215353
-
Long-term recording from single neurons in brain of unrestrained mammals
-
Strumwasser F. Long-term recording from single neurons in brain of unrestrained mammals. Science 127 3296 (1958) 469-470
-
(1958)
Science
, vol.127
, Issue.3296
, pp. 469-470
-
-
Strumwasser, F.1
-
30
-
-
5444250489
-
Solution-based assembly of conductive gold film on flexible polymer substrates
-
Supriya L., and Claus R.O. Solution-based assembly of conductive gold film on flexible polymer substrates. Langmuir 20 (2004) 8870-8876
-
(2004)
Langmuir
, vol.20
, pp. 8870-8876
-
-
Supriya, L.1
Claus, R.O.2
-
31
-
-
0042160197
-
Brain responses to micro-machined silicon devices
-
Szarowski D.H., Andersen M.D., Retterer S., Spence A.J., Isaacson M., Craighead H.G., et al. Brain responses to micro-machined silicon devices. Brain Res 983 (2003) 23-35
-
(2003)
Brain Res
, vol.983
, pp. 23-35
-
-
Szarowski, D.H.1
Andersen, M.D.2
Retterer, S.3
Spence, A.J.4
Isaacson, M.5
Craighead, H.G.6
-
32
-
-
0014955657
-
The structural organization of layer IV in the somatosensory region (SI) of mouse cerebral cortex
-
Woolsey T.A., and Van der Loos H. The structural organization of layer IV in the somatosensory region (SI) of mouse cerebral cortex. Brain Res 17 (1970) 205-242
-
(1970)
Brain Res
, vol.17
, pp. 205-242
-
-
Woolsey, T.A.1
Van der Loos, H.2
-
33
-
-
63449140043
-
-
Yeager JD, Bahr DF, Rector DM, Richards CD, Richards RF. Design and development of metal-polymer film systems for flexible electrodes used in cortical mapping. ASM MPMD Proc; Medical Device Materials IV: Proceedings of the Materials and Processes for Medical Devices 2007, ASM International, 2008, ISBN: 0-87170-861-2, in press.
-
Yeager JD, Bahr DF, Rector DM, Richards CD, Richards RF. Design and development of metal-polymer film systems for flexible electrodes used in cortical mapping. ASM MPMD Proc; Medical Device Materials IV: Proceedings of the Materials and Processes for Medical Devices 2007, ASM International, 2008, ISBN: 0-87170-861-2, in press.
-
-
-
|