메뉴 건너뛰기




Volumn 21, Issue 5, 2011, Pages

Capacitive micromachined ultrasonic transducers for medical imaging and therapy

Author keywords

[No Author keywords available]

Indexed keywords

ABLATIVE THERAPY; AIR-COUPLED; BASIC STRUCTURE; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCER; FABRICATION PROCESS; FRONT END ELECTRONICS; FUNCTIONAL IMAGING; HYBRID APPROACH; MEDICAL DIAGNOSTICS; MICRO ELECTRO MECHANICAL SYSTEM; OPERATING PRINCIPLES; THERAPEUTIC APPLICATION; TRANSDUCER ARRAY;

EID: 79955877535     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/21/5/054004     Document Type: Article
Times cited : (281)

References (51)
  • 1
    • 0028739970 scopus 로고
    • A surface micromachined electrostatic ultrasonic air transducer
    • Haller M I and Khuri-Yakub B T 1994 A surface micromachined electrostatic ultrasonic air transducer Proc. IEEE Ultrason. Symp. pp 1241-4
    • (1994) Proc. IEEE Ultrason. Symp. , pp. 1241-1244
    • Haller, M.I.1    Khuri-Yakub, B.T.2
  • 2
    • 79955812457 scopus 로고    scopus 로고
    • www.hitachi-medical.co.jp/medix/pdf/vol51/P31-34.pdf
  • 9
    • 17344390056 scopus 로고    scopus 로고
    • Micromachined capacitive ultrasonic transducers fabricated using silicon on insulator wafers
    • DOI 10.1016/S0167-9317(02)00423-9, PII S0167931702004239
    • Cianci E, Foglietti V, Caliano G and Pappalardo M 2002 Micromachined capacitive ultrasonic transducers fabricated using silicon on insulator wafers Microelectron. Eng. 61-62 1025-9 (Pubitemid 34613478)
    • (2002) Microelectronic Engineering , vol.61-62 , pp. 1025-1029
    • Cianci, E.1    Foglietti, V.2    Caliano, G.3    Pappalardo, M.4
  • 10
    • 0037387686 scopus 로고    scopus 로고
    • Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding
    • Huang Y, Ergun A S, Haeggström E, Badi M H and Khuri-Yakub B T 2003 Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding IEEE/ASME J. Microelectromech. Syst. 12 128-37
    • (2003) IEEE/ASME J. Microelectromech. Syst. , vol.12 , pp. 128-137
    • Huang Y, E.1
  • 26
    • 48149096016 scopus 로고    scopus 로고
    • Characterization of fabrication related gap-height variations in capacitive micromachined ultrasonic transducers
    • Lin D S, Zhuang X, Wong S H, Ergun A S, Kupnik M and Khuri-Yakub B T 2007 Characterization of fabrication related gap-height variations in capacitive micromachined ultrasonic transducers Proc. IEEE Ultrason. Symp. pp 523-6
    • (2007) Proc. IEEE Ultrason. Symp. , pp. 523-526
    • Lin, D.S.1    Zhuang, X.2    Wong, S.H.3    Ergun, A.S.4    Kupnik, M.5    Khuri-Yakub, B.T.6
  • 29
    • 50149091980 scopus 로고    scopus 로고
    • Fabricating capacitive micromachined ultrasonic transducers with direct wafer-bonding and LOCOS technology
    • Park K K, Lee H J, Kupnik M, Oralkan and Khuri-Yakub B T 2008 Fabricating capacitive micromachined ultrasonic transducers with direct wafer-bonding and LOCOS technology Proc. IEEE MEMS Conf. pp 339-42
    • (2008) Proc. IEEE MEMS Conf. , pp. 339-342
    • Park, K.K.1    Lee, H.J.2    Kupnik, M.3    Oralkan4    Khuri-Yakub, B.T.5
  • 32
    • 80054073886 scopus 로고    scopus 로고
    • CMUT with substrate-embedded springs for non-flexural plate movement
    • Nikoozadeh A and Khuri-Yakub P T 2010 CMUT with substrate-embedded springs for non-flexural plate movement Proc. IEEE Ultrason. Symp. submitted
    • (2010) Proc. IEEE Ultrason. Symp.
    • Nikoozadeh, A.1    Khuri-Yakub, P.T.2
  • 33
    • 60349121064 scopus 로고    scopus 로고
    • Capacitive micromachined ultrasonic transducers with piston-shaped membranes: Fabrication and experimental characterization
    • Huang Y, Zhuang X, Hæggstrom E O, Ergun A S, Cheng C-H and Khuri-Yakub B T 2009 Capacitive micromachined ultrasonic transducers with piston-shaped membranes: fabrication and experimental characterization IEEE Trans. Ultrason. Ferroelectr. Freq. Control 56 136-45
    • (2009) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.56 , pp. 136-145
    • Huang Y, Z.1
  • 34
    • 80054047597 scopus 로고    scopus 로고
    • Forward-looking intracardiac imaging catheters using fully integrated CMUT arrays
    • Nikoozadeh A et al 2010 Forward-looking intracardiac imaging catheters using fully integrated CMUT arrays Proc. IEEE Ultrason. Symp. submitted
    • (2010) Proc. IEEE Ultrason. Symp.
    • Nikoozadeh, A.1
  • 35
    • 73949119977 scopus 로고    scopus 로고
    • Three-dimensional photoacoustic imaging using a two-dimensional CMUT array
    • Vaithilingam S et al 2009 Three-dimensional photoacoustic imaging using a two-dimensional CMUT array IEEE Trans. Ultrason. Ferroelectr. Freq. Control 56 2411-19
    • (2009) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.56 , pp. 2411-2419
    • Vaithilingam, S.1
  • 39
    • 21644470582 scopus 로고    scopus 로고
    • Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics
    • U3-E-1, Proceedings - 2004 IEEE Ultrasonics Symposium: A Conference of the IEEE International Ultrasonics, Ferroelectrics, and Frequency Control Society, UFFC-S
    • Daft C, Calmes S, da Graca D, Patel K, Wagner P and Ladabaum I 2004 Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics Proc. IEEE Ultrason. Symp. pp 493-6 (Pubitemid 40927164)
    • (2004) Proceedings - IEEE Ultrasonics Symposium , vol.1 , pp. 493-496
    • Daft, C.1    Calmes, S.2    Graca, D.D.3    Patel, K.4    Wagner, P.5    Ladabaum, I.6
  • 41
  • 44
    • 4143113640 scopus 로고    scopus 로고
    • Real-time in vivo imaging with capacitive micromachined ultrasound transducer (CMUT) linear arrays
    • Mills D M and Smith L S 2003 Real-time in vivo imaging with capacitive micromachined ultrasound transducer (CMUT) linear arrays Proc. IEEE Ultrason. Symp. pp 568-71
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 568-571
    • Mills, D.M.1    Smith, L.S.2
  • 45
    • 4143053716 scopus 로고    scopus 로고
    • Fully sampled matrix transducer for real time 3D ultrasonic imaging
    • Savord B and Solomon R 2003 Fully sampled matrix transducer for real time 3D ultrasonic imaging Proc. IEEE Ultrason. Symp. pp 945-9
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 945-949
    • Savord, B.1    Solomon, R.2
  • 47
    • 0036883372 scopus 로고    scopus 로고
    • Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging
    • Wang Y, Stephens D N and O'Donnell M 2002 Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging IEEE Trans. Ultrason. Ferroelectr. Freq. Control 49 1652-64
    • (2002) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.49 , pp. 1652-1664
    • Wang, Y.1    Stephens, D.N.2    O'Donnell, M.3
  • 51
    • 0031649731 scopus 로고    scopus 로고
    • Lifetime estimates and unique failure mechanisms of the digital micromirror device (DMD)
    • Douglass M R 1998 Lifetime estimates and unique failure mechanisms of the digital micromirror device (DMD) Proc. IRPS 9-16
    • (1998) Proc. IRPS , pp. 9-16
    • Douglass, M.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.