1
-
-
28844501315
-
Threeand 4-dimensional ultrasound in obstetrics and gynecology: Proceedings of the American Institute of Ultrasound in Medicine Consensus Conference
-
B. R. Benacerraf, C. B. Benson, A. Z. Abuhamad, J. A. Copel, J. S. Abramowicz, G. R. Devore, P. M. Doubilet, W. Lee, A. S. Lev-Toaff, E. Merz, T. R. Nelson, M. J. O'Neill, A. K. Parsons, L. D. Platt, D. H. Pretorius, and I. E. Timor-Tritsch, "Threeand 4-dimensional ultrasound in obstetrics and gynecology: Proceedings of the American Institute of Ultrasound in Medicine Consensus Conference," J. Ultrasound Med., vol. 24, no. 12, pp. 1587-1597, 2005.
-
(2005)
J. Ultrasound Med.
, vol.24
, Issue.12
, pp. 1587-1597
-
-
Benacerraf, B.R.1
Benson, C.B.2
Abuhamad, A.Z.3
Copel, J.A.4
Abramowicz, J.S.5
Devore, G.R.6
Doubilet, P.M.7
Lee, W.8
Lev-Toaff, A.S.9
Merz, E.10
Nelson, T.R.11
O'neill, M.J.12
Parsons, A.K.13
Platt, L.D.14
Pretorius, D.H.15
Timor-Tritsch, I.E.16
-
2
-
-
0000566101
-
Fabrication and characterization of transducer elements in two-dimensional arrays for medical ultrasound imaging
-
D. Turnbull and F. Foster, "Fabrication and characterization of transducer elements in two-dimensional arrays for medical ultrasound imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, no. 4, pp. 464-475, 1992.
-
(1992)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.39
, Issue.4
, pp. 464-475
-
-
Turnbull, D.1
Foster, F.2
-
3
-
-
0032072173
-
Characterizing ultrasonic transducers using radiation efficiency and reception noise figure
-
T. Rhyne, "Characterizing ultrasonic transducers using radiation efficiency and reception noise figure," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, no. 3, pp. 559-566, 1998.
-
(1998)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.45
, Issue.3
, pp. 559-566
-
-
Rhyne, T.1
-
4
-
-
13844256295
-
Coherentarray imaging using phased subarrays. Part I: Basic principles
-
J. Johnson, M. Karaman, and B. T. Khuri-Yakub, "Coherentarray imaging using phased subarrays. Part I: Basic principles," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 1, pp. 37-50, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.1
, pp. 37-50
-
-
Johnson, J.1
Karaman, M.2
Khuri-Yakub, B.T.3
-
5
-
-
33847135726
-
Reconfigurable arrays for portable ultrasound
-
R. Fisher, K. Thomenius, R. Wodnicki, R. Thomas, S. Cogan, C. Hazard, W. Lee, D. Mills, B. Khuri-Yakub, A. Ergun, and G. Yaralioglu, "Reconfigurable arrays for portable ultrasound," in Proc. IEEE Ultrason. Symp., vol. 1, 2005, pp. 495-499.
-
(2005)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 495-499
-
-
Fisher, R.1
Thomenius, K.2
Wodnicki, R.3
Thomas, R.4
Cogan, S.5
Hazard, C.6
Lee, W.7
Mills, D.8
Khuri-Yakub, B.9
Ergun, A.10
Yaralioglu, G.11
-
6
-
-
0038155505
-
A multichannel pipeline analog-to-digital converter for an integrated 3-D ultrasound imaging system
-
K. Kaviani, O. Oralkan, P. Khuri-Yakub, and B. Wooley, "A multichannel pipeline analog-to-digital converter for an integrated 3-D ultrasound imaging system," IEEE J. Solid-State Circuits, vol. 38, no. 7, pp. 1266-1270, 2003.
-
(2003)
IEEE J. Solid-State Circuits
, vol.38
, Issue.7
, pp. 1266-1270
-
-
Kaviani, K.1
Oralkan, O.2
Khuri-Yakub, P.3
Wooley, B.4
-
7
-
-
40549104896
-
Two approaches to electronically scanned 3D imaging using cMUTs
-
C. M. W. Daft, S. Panda, P. A. Wagner, and I. Ladabaum, "Two approaches to electronically scanned 3D imaging using cMUTs," in Proc. IEEE Ultrason. Symp., 2006, pp. 685-688.
-
(2006)
Proc. IEEE Ultrason. Symp.
, pp. 685-688
-
-
Daft, C.M.W.1
Panda, S.2
Wagner, P.A.3
Ladabaum, I.4
-
8
-
-
0027840841
-
VLSI circuits for adaptive digital beamforming in ultrasound imaging
-
M. Karaman, A. Atalar, and H. Koymen, "VLSI circuits for adaptive digital beamforming in ultrasound imaging," IEEE Trans. Med. Imag., vol. 12, no. 4, pp. 711-720, 1993.
-
(1993)
IEEE Trans. Med. Imag.
, vol.12
, Issue.4
, pp. 711-720
-
-
Karaman, M.1
Atalar, A.2
Koymen, H.3
-
9
-
-
15844367336
-
Coded excitation for diagnostic ultrasound: A system developer's perspective
-
R. Chiao and X. Hao, "Coded excitation for diagnostic ultrasound: A system developer's perspective," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 2, pp. 160-170, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.2
, pp. 160-170
-
-
Chiao, R.1
Hao, X.2
-
10
-
-
21644470582
-
Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics
-
C. Daft, S. Calmes, D. da Graca, K. Patel, P. Wagner, and I. Ladabaum, "Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics," in Proc. IEEE Ultrason. Symp., vol. 1, 2004, pp. 493-496.
-
(2004)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 493-496
-
-
Daft, C.1
Calmes, S.2
Da Graca, D.3
Patel, K.4
Wagner, P.5
Ladabaum, I.6
-
11
-
-
4143053716
-
Fully sampled matrix transducer for real time 3D ultrasonic imaging
-
B. Savord and R. Solomon, "Fully sampled matrix transducer for real time 3D ultrasonic imaging," in Proc. IEEE Ultrason. Symp., vol. 1, 2003, pp. 945-953.
-
(2003)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 945-953
-
-
Savord, B.1
Solomon, R.2
-
12
-
-
0033899427
-
Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process
-
P. C. Eccardt and K. Niederer, "Micromachined ultrasound transducers with improved coupling factors from a CMOS compatible process," Ultrasonics, vol. 38, no. 1-8, pp. 774-780, 2000.
-
(2000)
Ultrasonics
, vol.38
, Issue.1-8
, pp. 774-780
-
-
Eccardt, P.C.1
Niederer, K.2
-
13
-
-
0035731025
-
Cost-effective and manufacturable route to the fabrication of high-density 2D micromachined ultrasonic transducer arrays and (CMOS) signal conditioning electronics on the same silicon substrate
-
R. A. Noble, R. R. Davies, M. M. Day, L. Koker, D. O. King, K.M. Brunson, A. R. D. Jones, J. S. McIntosh, D. A. Hutchins, T. J. Robertson, and P. Saul, "Cost-effective and manufacturable route to the fabrication of high-density 2D micromachined ultrasonic transducer arrays and (CMOS) signal conditioning electronics on the same silicon substrate," in Proc. IEEE Ultrason. Symp., vol. 2, 2001, pp. 941-944.
-
(2001)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 941-944
-
-
Noble, R.A.1
Davies, R.R.2
Day, M.M.3
Koker, L.4
King, D.O.5
Brunson, K.M.6
Jones, A.R.D.7
McIntosh, J.S.8
Hutchins, D.A.9
Robertson, T.J.10
Saul, P.11
-
14
-
-
0041886817
-
Front-end processor using BBD distributed delay-sum architecture for micromachined ultrasonic sensor array
-
Y. Mo, T. Tanaka, K. Inoue, K. Yamashita, and Y. Suzuki, "Front-end processor using BBD distributed delay-sum architecture for micromachined ultrasonic sensor array," J. Microelectromech. Syst., vol. 12, no. 4, pp. 506-512, 2003.
-
(2003)
J. Microelectromech. Syst.
, vol.12
, Issue.4
, pp. 506-512
-
-
Mo, Y.1
Tanaka, T.2
Inoue, K.3
Yamashita, K.4
Suzuki, Y.5
-
15
-
-
33847116793
-
CMUTs and electronics for 2D and 3D imaging: Monolithic integration, in-handle chip sets and system implications
-
C. Daft, P. Wagner, B. Bymaster, S. Panda, K. Patel, and I. Ladabaum, "cMUTs and electronics for 2D and 3D imaging: Monolithic integration, in-handle chip sets and system implications," in Proc. IEEE Ultrason. Symp., vol. 1, 2005, pp. 463-474.
-
(2005)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 463-474
-
-
Daft, C.1
Wagner, P.2
Bymaster, B.3
Panda, S.4
Patel, K.5
Ladabaum, I.6
-
16
-
-
0028542341
-
CMOS chip for invasive ultrasound imaging
-
W. C. Black, Jr. and D. N. Stephens, "CMOS chip for invasive ultrasound imaging," IEEE J. Solid-State Circuits, vol. 29, no. 11, pp. 1381-1387, 1994.
-
(1994)
IEEE J. Solid-State Circuits
, vol.29
, Issue.11
, pp. 1381-1387
-
-
Black Jr., W.C.1
Stephens, D.N.2
-
17
-
-
0030363815
-
A 2.5 MHz 2D array with Z-axis backing
-
M. Greenstein, P. Lum, H. Yoshida, and M. Seyed-Bolorforosh, "A 2.5 MHz 2D array with Z-axis backing," in Proc. IEEE Ultrason. Symp., vol. 2, 1996, pp. 1513-1516.
-
(1996)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 1513-1516
-
-
Greenstein, M.1
Lum, P.2
Yoshida, H.3
Seyed-Bolorforosh, M.4
-
18
-
-
0032012560
-
Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection
-
R. Davidsen and S. Smith, "Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, no. 2, pp. 338-348, 1998.
-
(1998)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.45
, Issue.2
, pp. 338-348
-
-
Davidsen, R.1
Smith, S.2
-
19
-
-
0027703127
-
Two-dimensional array transducers using thick film connection technology
-
S. Smith and E. Light, "Two-dimensional array transducers using thick film connection technology," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 40, no. 6, pp. 727-734, 1993.
-
(1993)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.40
, Issue.6
, pp. 727-734
-
-
Smith, S.1
Light, E.2
-
20
-
-
0031233540
-
A demountable interconnect system for a 50 × 50 ultrasonic imaging transducer array
-
L. Daane and M. Greenstein, "A demountable interconnect system for a 50 × 50 ultrasonic imaging transducer array," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 5, pp. 978-982, 1997.
-
(1997)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.44
, Issue.5
, pp. 978-982
-
-
Daane, L.1
Greenstein, M.2
-
21
-
-
0033718864
-
Highdensity flexible interconnect for two-dimensional ultrasound arrays
-
J. Fiering, P. Hultman, W. Lee, E. Light, and S. Smith, "Highdensity flexible interconnect for two-dimensional ultrasound arrays," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 47, no. 3, pp. 764-770, 2000.
-
(2000)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.47
, Issue.3
, pp. 764-770
-
-
Fiering, J.1
Hultman, P.2
Lee, W.3
Light, E.4
Smith, S.5
-
22
-
-
8344252796
-
A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography
-
W. Lee, S. Idriss, P. Wolf, and S. Smith, "A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 51, no. 10, pp. 1334-1346, 2004.
-
(2004)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.51
, Issue.10
, pp. 1334-1346
-
-
Lee, W.1
Idriss, S.2
Wolf, P.3
Smith, S.4
-
23
-
-
33644859258
-
Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
-
I. Cicek, A. Bozkurt, and M. Karaman, "Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 12, pp. 2235-2241, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.12
, pp. 2235-2241
-
-
Cicek, I.1
Bozkurt, A.2
Karaman, M.3
-
24
-
-
40549133343
-
A low-noise front-end circuit for 2D cMUT arrays
-
U. Guler and A. Bozkurt, "A low-noise front-end circuit for 2D cMUT arrays," in Proc. IEEE Ultrason. Symp., 2006, pp. 689-692.
-
(2006)
Proc. IEEE Ultrason. Symp.
, pp. 689-692
-
-
Guler, U.1
Bozkurt, A.2
-
25
-
-
40549101466
-
Floating-gate based CMUT sensing circuit using capacitive feedback charge amplifier
-
S.-Y. Peng, M. Qureshi, A. Basu, R. Guldiken, F. Degertekin, and P. Hasler, "Floating-gate based CMUT sensing circuit using capacitive feedback charge amplifier," in Proc. IEEE Ultrason. Symp., 2006, pp. 2425-2428.
-
(2006)
Proc. IEEE Ultrason. Symp.
, pp. 2425-2428
-
-
Peng, S.-Y.1
Qureshi, M.2
Basu, A.3
Guldiken, R.4
Degertekin, F.5
Hasler, P.6
-
26
-
-
0034579981
-
An efficient electrical addressing method using through-wafer vias for two-dimensional ultrasonic arrays
-
C. Cheng, E. Chow, X. Jin, S. Ergun, and B. Khuri-Yakub, "An efficient electrical addressing method using through-wafer vias for two-dimensional ultrasonic arrays," in Proc. IEEE Ultrason. Symp., 2000, pp. 1179-1182.
-
(2000)
Proc. IEEE Ultrason. Symp.
, pp. 1179-1182
-
-
Cheng, C.1
Chow, E.2
Jin, X.3
Ergun, S.4
Khuri-Yakub, B.5
-
27
-
-
17644394942
-
Real-time 3D transesophageal echocardiography
-
E. Pua, S. Idriss, P. Wolf, and S. Smith, "Real-time 3D transesophageal echocardiography," Ultrason. Imag., vol. 26, pp. 217-232, 2004.
-
(2004)
Ultrason. Imag.
, vol.26
, pp. 217-232
-
-
Pua, E.1
Idriss, S.2
Wolf, P.3
Smith, S.4
-
28
-
-
0034813298
-
Real-time threedimensional intracardiac echocardiography
-
E. Light, S. Idriss, P. Wolf, and S. Smith, "Real-time threedimensional intracardiac echocardiography," Ultrasound Med. Biol., vol. 27, no. 9, pp. 1177-1183, 2001.
-
(2001)
Ultrasound Med. Biol.
, vol.27
, Issue.9
, pp. 1177-1183
-
-
Light, E.1
Idriss, S.2
Wolf, P.3
Smith, S.4
-
29
-
-
4143049306
-
Improved equivalent circuit and finite element method modeling of capacitive micromachined ultrasonic transducers
-
G. Yaralioglu, M. Badi, A. Ergun, and B. Khuri-Yakub, "Improved equivalent circuit and finite element method modeling of capacitive micromachined ultrasonic transducers," in Proc. IEEE Ultrason. Symp., vol. 1, 2003, pp. 469-472.
-
(2003)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 469-472
-
-
Yaralioglu, G.1
Badi, M.2
Ergun, A.3
Khuri-Yakub, B.4
-
30
-
-
21644445650
-
Analytical calculation of collapse voltage of CMUT membrane [capacitive micromachined ultrasonic transducers]
-
A. Nikoozadeh, B. Bayram, G. Yaralioglu, and B. Khuri-Yakub, "Analytical calculation of collapse voltage of CMUT membrane [capacitive micromachined ultrasonic transducers]," in Proc. IEEE Ultrason. Symp., vol. 1, 2004, pp. 256-259.
-
(2004)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 256-259
-
-
Nikoozadeh, A.1
Bayram, B.2
Yaralioglu, G.3
Khuri-Yakub, B.4
-
31
-
-
33644849050
-
Finite-element analysis of capacitive micromachined ultrasonic transducers
-
G. Yaralioglu, S. Ergun, and B. Khuri-Yakub, "Finite-element analysis of capacitive micromachined ultrasonic transducers," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 12, pp. 2185-2198, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.12
, pp. 2185-2198
-
-
Yaralioglu, G.1
Ergun, S.2
Khuri-Yakub, B.3
-
32
-
-
0032162663
-
The microfabrication of capacitive ultrasonic transducers
-
X. Jin, I. Ladabaum, and B. Khuri-Yakub, "The microfabrication of capacitive ultrasonic transducers," J. Microelectromech. Syst., vol. 7, no. 3, pp. 295-302, 1998.
-
(1998)
J. Microelectromech. Syst.
, vol.7
, Issue.3
, pp. 295-302
-
-
Jin, X.1
Ladabaum, I.2
Khuri-Yakub, B.3
-
33
-
-
33644863891
-
Capacitive micromachined ultrasonic transducers: Fabrication technology
-
A. Ergun, Y. Huang, X. Zhuang, O. Oralkan, G. Yarahoglu, and B. Khuri-Yakub, "Capacitive micromachined ultrasonic transducers: Fabrication technology," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 12, pp. 2242-2258, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.12
, pp. 2242-2258
-
-
Ergun, A.1
Huang, Y.2
Zhuang, X.3
Oralkan, O.4
Yarahoglu, G.5
Khuri-Yakub, B.6
-
34
-
-
0012074770
-
Electrical through-wafer interconnects with 0.05 pico farads parasitic capacitance on 400 μm thick silicon substrates
-
presented at, Hilton Head Island, SC
-
C.-H. Cheng, A. Ergun, and B. Khuri-Yakub, "Electrical through-wafer interconnects with 0.05 pico farads parasitic capacitance on 400 μm thick silicon substrates," presented at Tech. Dig. Solid-State Sensor, Actuator, and Microsystems Workshop, Hilton Head Island, SC, 2002, pp. 157-160.
-
(2002)
Tech. Dig. Solid-State Sensor, Actuator, and Microsystems Workshop
, pp. 157-160
-
-
Cheng, C.-H.1
Ergun, A.2
Khuri-Yakub, B.3
-
35
-
-
40549112101
-
-
Ph.D. dissertation, Department of Electrical Engineering, Stanford University, Stanford, CA
-
O. Oralkan, "Acoustical imaging using capacitive micromachined ultrasonic transducer arrays: Devices, circuits, and systems," Ph.D. dissertation, Department of Electrical Engineering, Stanford University, Stanford, CA, 2004.
-
(2004)
Acoustical Imaging Using Capacitive Micromachined Ultrasonic Transducer Arrays: Devices, Circuits, and Systems
-
-
Oralkan, O.1
-
36
-
-
85057115507
-
5 V-to-75 v CMOS output interface circuits
-
p. 283
-
M. Declerq, M. Schubert, and F. Clement, "5 V-to-75 V CMOS output interface circuits," in Proc. IEEE Int. Solid-State Circuits Conf., 1993, pp. 162-163, p. 283.
-
(1993)
Proc. IEEE Int. Solid-State Circuits Conf.
, pp. 162-163
-
-
Declerq, M.1
Schubert, M.2
Clement, F.3
-
38
-
-
84873997324
-
-
Analog Devices. Analog Devices, Inc., Boston, MA
-
Analog Devices, "AD8067 high gain bandwidth product, precision fastFET op amp data sheet," Analog Devices, Inc., Boston, MA, 2006.
-
(2006)
AD8067 High Gain Bandwidth Product Precision FastFET Op Amp Data Sheet
-
-
-
39
-
-
11944272343
-
Finepitch wafer bumping and assembly for high density detector systems
-
A. Huffman, R. LaBennett, S. Bonafede, and C. Statler, "Finepitch wafer bumping and assembly for high density detector systems," in Conf. Rec. IEEE Nucl. Sci. Symp., vol. 5, 2003, pp. 3522-3526.
-
(2003)
Conf. Rec. IEEE Nucl. Sci. Symp.
, vol.5
, pp. 3522-3526
-
-
Huffman, A.1
Labennett, R.2
Bonafede, S.3
Statler, C.4
-
41
-
-
72749124084
-
-
Precision Interconnect. Tyco Electronic Corp., Berwyn, PA
-
Precision Interconnect, "MODULUS3 cable assemblies data sheet," Tyco Electronic Corp., Berwyn, PA, 2004.
-
(2004)
MODULUS3 Cable Assemblies Data Sheet
-
-
-
42
-
-
0020330145
-
Sensitivity considerations for PVDF hydrophones using the spot-poled membrane design
-
G. Harris, "Sensitivity considerations for PVDF hydrophones using the spot-poled membrane design," IEEE Trans. Sonics Ultrason., vol. 29, no. 6, pp. 370-376, 1982.
-
(1982)
IEEE Trans. Sonics Ultrason.
, vol.29
, Issue.6
, pp. 370-376
-
-
Harris, G.1
-
43
-
-
34247492054
-
Biocompatible coatings for CMUTs in a harsh, aqueous environment
-
X. Zhuang, A. Nikoozadeh, M. Beasley, G. Yaralioglu, B. Khuri- Yakub, and B. L. Pruitt, "Biocompatible coatings for CMUTs in a harsh, aqueous environment," J. Microelectromech. Syst., vol. 17, no. 5, pp. 994-1001, 2007.
-
(2007)
J. Microelectromech. Syst.
, vol.17
, Issue.5
, pp. 994-1001
-
-
Zhuang, X.1
Nikoozadeh, A.2
Beasley, M.3
Yaralioglu, G.4
Khuri-Yakub, B.5
Pruitt, B.L.6
-
44
-
-
0033295240
-
Micromachined transducer design for minimized generation of surface waves
-
K. Niederer, P.-C. Eccardt, H. Meixner, and R. Lerch, "Micromachined transducer design for minimized generation of surface waves," in Proc. IEEE Ultrason. Symp., vol. 2, 1999, pp. 1137-1139.
-
(1999)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 1137-1139
-
-
Niederer, K.1
Eccardt, P.-C.2
Meixner, H.3
Lerch, R.4
-
45
-
-
0034579921
-
Time-domain models of MUT array cross-talk in silicon substrates
-
G. Wojcik, J. Mould, P. Reynolds, A. Fitzgerald, P. Wagner, and I. Ladabaum, "Time-domain models of MUT array cross-talk in silicon substrates," in Proc. IEEE Ultrason. Symp., vol. 1, 2000, pp. 909-914.
-
(2000)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 909-914
-
-
Wojcik, G.1
Mould, J.2
Reynolds, P.3
Fitzgerald, A.4
Wagner, P.5
Ladabaum, I.6
-
46
-
-
33847103168
-
Analysis of crosstalk between fluid coupled cmut membranes
-
P.-C. Eccardt, A. Lohfink, and H.-G. Garssen, "Analysis of crosstalk between fluid coupled cmut membranes," in Proc. IEEE Ultrason. Symp., vol. 1, 2005, pp. 593-596.
-
(2005)
Proc. IEEE Ultrason. Symp.
, vol.1
, pp. 593-596
-
-
Eccardt, P.-C.1
Lohfink, A.2
Garssen, H.-G.3
-
47
-
-
33644855948
-
Acoustic coupling in capacitive microfabricated ultrasonic transducers: Modeling and experiments
-
A. Caronti, A. Savoia, G. Caliano, and M. Pappalardo, "Acoustic coupling in capacitive microfabricated ultrasonic transducers: Modeling and experiments," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 12, pp. 2220-2234, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.52
, Issue.12
, pp. 2220-2234
-
-
Caronti, A.1
Savoia, A.2
Caliano, G.3
Pappalardo, M.4
-
48
-
-
33847720790
-
Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays
-
B. Bayram, M. Kupnik, G. G. Yaralioglu, Ö. Oralkan, A. S. Ergun, D.-S. Lin, S. H. Wong, and B. T. Khuri-Yakub, "Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 54, no. 2, pp. 418-430, 2007.
-
(2007)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.54
, Issue.2
, pp. 418-430
-
-
Bayram, B.1
Kupnik, M.2
Yaralioglu, G.G.3
Oralkan, O.4
Ergun, A.S.5
Lin, D.-S.6
Wong, S.H.7
Khuri-Yakub, B.T.8
-
49
-
-
33847126930
-
An endoscopic imaging system based on a twodimensional CMUT array: Real-time imaging results
-
I. O. Wygant, X. Zhuang, D. T. Yeh, S. Vaithilingam, A. Nikoozadeh, O. Oralkan, A. S. Ergun, M. Karaman, and B. T. Khuri-Yakub, "An endoscopic imaging system based on a twodimensional CMUT array: Real-time imaging results," in Proc. IEEE Ultrason. Symp., vol. 2, 2005, pp. 792-795.
-
(2005)
Proc. IEEE Ultrason. Symp.
, vol.2
, pp. 792-795
-
-
Wygant, I.O.1
Zhuang, X.2
Yeh, D.T.3
Vaithilingam, S.4
Nikoozadeh, A.5
Oralkan, O.6
Ergun, A.S.7
Karaman, M.8
Khuri-Yakub, B.T.9
-
50
-
-
15044352366
-
OsiriX: An open-source software for navigating in multidimensional DICOM images
-
A. Rosset, L. Spadola, and O. Ratib, "OsiriX: An open-source software for navigating in multidimensional DICOM images," J. Digit. Imag., vol. V17, no. 3, pp. 205-216, 2004.
-
(2004)
J. Digit. Imag.
, vol.17
, Issue.3
, pp. 205-216
-
-
Rosset, A.1
Spadola, L.2
Ratib, O.3
-
51
-
-
33745363333
-
Beamforming and hardware design for a multichannel frontend integrated circuit for real-time 3D catheter-based ultrasonic imaging
-
I. Wygant, M. Karaman, O. Oralkan, and B. Khuri-Yakub, "Beamforming and hardware design for a multichannel frontend integrated circuit for real-time 3D catheter-based ultrasonic imaging," in Proc. SPIE Med. Imag. Conf., vol. 6147, 2006, pp. 1-8.
-
(2006)
Proc. SPIE Med. Imag. Conf.
, vol.6147
, pp. 1-8
-
-
Wygant, I.1
Karaman, M.2
Oralkan, O.3
Khuri-Yakub, B.4
-
52
-
-
0036827072
-
Capacitive micromachined ultrasonic transducers: Next-generation arrays for acoustic imaging?
-
Ö. Oralkan, A. S. Ergun, J. A. Johnson, M. Karaman, U. Demirci, K. Kaviani, T. H. Lee, and B. T. Khuri-Yakub, "Capacitive micromachined ultrasonic transducers: Next-generation arrays for acoustic imaging?," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 49, no. 11, pp. 1596-1610, 2002.
-
(2002)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.49
, Issue.11
, pp. 1596-1610
-
-
Oralkan, O.1
Ergun, A.S.2
Johnson, J.A.3
Karaman, M.4
Demirci, U.5
Kaviani, K.6
Lee, T.H.7
Khuri-Yakub, B.T.8
-
53
-
-
0003569609
-
-
Englewood Cliffs, NJ: Prentice-Hall, Inc.
-
G. S. Kino, Acoustic Waves: Devices, Imaging, and Analog Signal Processing. Englewood Cliffs, NJ: Prentice-Hall, Inc., 1987.
-
(1987)
Acoustic Waves: Devices, Imaging, and Analog Signal Processing
-
-
Kino, G.S.1
-
54
-
-
84873989877
-
-
Trondhejm, Norway: Emantec
-
B. A. J. Angelsen, Ultrasound Imaging: Waves, Signals, and Signal Processing. vol. 1, Trondhejm, Norway: Emantec, 2000.
-
(2000)
Ultrasound Imaging: Waves, Signals, and Signal Processing.
, vol.1
-
-
Angelsen, B.A.J.1
|