Volumn 31, Issue 1, 2015, Pages 25-42

Minimally invasive monitoring

Author keywords

Arterial pressure; Cardiac output; Hemodynamic monitoring; Pulse contour analysis; Thermodilution; Vascular resistance

Indexed keywords

ARTERIAL PRESSURE WAVEFORM ANALYSIS; ARTERIAL PRESSURE WAVEFORM ANALYSIS DEVICE; BLOOD PRESSURE MEASUREMENT; CARDIOVASCULAR MONITORING DEVICE; HEART OUTPUT; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; MINIMALLY INVASIVE MONITORING; MINIMALLY INVASIVE PROCEDURE; PRESSURE RECORDING ANALYTICAL METHOD; REVIEW; BLOOD PRESSURE; DEVICES; HEMODYNAMICS; PHOTOELECTRIC PLETHYSMOGRAPHY; PHYSIOLOGIC MONITORING; PHYSIOLOGY; PROCEDURES;

EID: 84915748309     PISSN: 07490704     EISSN: 15578232     Source Type: Journal    
DOI: 10.1016/j.ccc.2014.08.002     Document Type: Review
Times cited : (29)

References (110)
  • 2
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • Wesseling K.H., Jansen J.R., Settels J.J., et al. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. JAppl Physiol (1985) 1993, 74:2566-2573.
    • (1993) JAppl Physiol (1985) , vol.74 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.2    Settels, J.J.3
  • 3
    • 0032734448 scopus 로고    scopus 로고
    • Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution
    • Goedje O., Hoeke K., Lichtwarck-Aschoff M., et al. Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. Crit Care Med 1999, 27:2407-2412.
    • (1999) Crit Care Med , vol.27 , pp. 2407-2412
    • Goedje, O.1    Hoeke, K.2    Lichtwarck-Aschoff, M.3
  • 4
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives
    • Reuter D.A., Huang C., Edrich T., et al. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg 2010, 110:799-811.
    • (2010) Anesth Analg , vol.110 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3
  • 5
    • 80052023330 scopus 로고    scopus 로고
    • Precision of the transpulmonary thermodilution measurements
    • Monnet X., Persichini R., Ktari M., et al. Precision of the transpulmonary thermodilution measurements. Crit Care 2011, 15:R204.
    • (2011) Crit Care , vol.15 , pp. R204
    • Monnet, X.1    Persichini, R.2    Ktari, M.3
  • 6
    • 84892041975 scopus 로고    scopus 로고
    • Clinical utility of extravascular lung water measurements
    • Springer-Verlag, Berlin; Heidelberg (Germany); New York, J.L. Vincent (Ed.)
    • Monnet X., Teboul J.L. Clinical utility of extravascular lung water measurements. Yearbook of intensive care and emergency medicine 2009, 433-442. Springer-Verlag, Berlin; Heidelberg (Germany); New York. J.L. Vincent (Ed.).
    • (2009) Yearbook of intensive care and emergency medicine , pp. 433-442
    • Monnet, X.1    Teboul, J.L.2
  • 7
    • 73449127209 scopus 로고    scopus 로고
    • Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function
    • Jabot J., Monnet X., Lamia B., et al. Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function. Crit Care Med 2009, 37:2913-2918.
    • (2009) Crit Care Med , vol.37 , pp. 2913-2918
    • Jabot, J.1    Monnet, X.2    Lamia, B.3
  • 8
    • 79952965623 scopus 로고    scopus 로고
    • Complications related to less-invasive haemodynamic monitoring
    • Belda F.J., Aguilar G., Teboul J.L., et al. Complications related to less-invasive haemodynamic monitoring. Br J Anaesth 2011, 106:482-486.
    • (2011) Br J Anaesth , vol.106 , pp. 482-486
    • Belda, F.J.1    Aguilar, G.2    Teboul, J.L.3
  • 9
    • 38549151697 scopus 로고    scopus 로고
    • Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
    • Hamzaoui O., Monnet X., Richard C., et al. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008, 36:434-440.
    • (2008) Crit Care Med , vol.36 , pp. 434-440
    • Hamzaoui, O.1    Monnet, X.2    Richard, C.3
  • 10
    • 0030832772 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: a comparison with thermodilution
    • Linton R., Band D., O'Brien T., et al. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med 1997, 25:1796-1800.
    • (1997) Crit Care Med , vol.25 , pp. 1796-1800
    • Linton, R.1    Band, D.2    O'Brien, T.3
  • 11
    • 0030831649 scopus 로고    scopus 로고
    • Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
    • Kurita T., Morita K., Kato S., et al. Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesth 1997, 79:770-775.
    • (1997) Br J Anaesth , vol.79 , pp. 770-775
    • Kurita, T.1    Morita, K.2    Kato, S.3
  • 12
    • 60449102439 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique
    • Cecconi M., Dawson D., Grounds R.M., et al. Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009, 35:498-504.
    • (2009) Intensive Care Med , vol.35 , pp. 498-504
    • Cecconi, M.1    Dawson, D.2    Grounds, R.M.3
  • 13
    • 0021249532 scopus 로고
    • The static elastic properties of 45 human thoracic and 20 abdominal aortas invitro and the parameters of a new model
    • Langewouters G.J., Wesseling K.H., Goedhard W.J. The static elastic properties of 45 human thoracic and 20 abdominal aortas invitro and the parameters of a new model. JBiomech 1984, 17:425-435.
    • (1984) JBiomech , vol.17 , pp. 425-435
    • Langewouters, G.J.1    Wesseling, K.H.2    Goedhard, W.J.3
  • 14
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    • De Backer D., Marx G., Tan A., et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med 2011, 37:233-240.
    • (2011) Intensive Care Med , vol.37 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3
  • 15
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano S.M., Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002, 30:1834-1841.
    • (2002) Crit Care Med , vol.30 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 16
    • 78549248199 scopus 로고    scopus 로고
    • Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
    • Hadian M., Kim H.K., Severyn D.A., et al. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010, 14:R212.
    • (2010) Crit Care , vol.14 , pp. R212
    • Hadian, M.1    Kim, H.K.2    Severyn, D.A.3
  • 17
    • 1942454804 scopus 로고    scopus 로고
    • Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output
    • Bein B., Worthmann F., Tonner P.H., et al. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output. JCardiothorac Vasc Anesth 2004, 18:185-189.
    • (2004) JCardiothorac Vasc Anesth , vol.18 , pp. 185-189
    • Bein, B.1    Worthmann, F.2    Tonner, P.H.3
  • 18
    • 0032817727 scopus 로고    scopus 로고
    • Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    • Buhre W., Weyland A., Kazmaier S., et al. Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. JCardiothorac Vasc Anesth 1999, 13:437-440.
    • (1999) JCardiothorac Vasc Anesth , vol.13 , pp. 437-440
    • Buhre, W.1    Weyland, A.2    Kazmaier, S.3
  • 19
    • 20444419379 scopus 로고    scopus 로고
    • Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysis
    • Felbinger T.W., Reuter D.A., Eltzschig H.K., et al. Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysis. JClin Anesth 2005, 17:241-248.
    • (2005) JClin Anesth , vol.17 , pp. 241-248
    • Felbinger, T.W.1    Reuter, D.A.2    Eltzschig, H.K.3
  • 20
    • 0036095676 scopus 로고    scopus 로고
    • Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: evaluation of a new algorithm
    • Felbinger T.W., Reuter D.A., Eltzschig H.K., et al. Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: evaluation of a new algorithm. JClin Anesth 2002, 14:296-301.
    • (2002) JClin Anesth , vol.14 , pp. 296-301
    • Felbinger, T.W.1    Reuter, D.A.2    Eltzschig, H.K.3
  • 21
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O., Hoke K., Goetz A.E., et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 2002, 30:52-58.
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3
  • 22
    • 0042482769 scopus 로고    scopus 로고
    • Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients
    • Rodig G., Prasser C., Keyl C., et al. Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients. Br J Anaesth 1999, 82:525-530.
    • (1999) Br J Anaesth , vol.82 , pp. 525-530
    • Rodig, G.1    Prasser, C.2    Keyl, C.3
  • 23
    • 0033998711 scopus 로고    scopus 로고
    • Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery
    • Zollner C., Haller M., Weis M., et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery. JCardiothorac Vasc Anesth 2000, 14:125-129.
    • (2000) JCardiothorac Vasc Anesth , vol.14 , pp. 125-129
    • Zollner, C.1    Haller, M.2    Weis, M.3
  • 24
    • 62849122288 scopus 로고    scopus 로고
    • Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients
    • Monnet X., Osman D., Ridel C., et al. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med 2009, 37:951-956.
    • (2009) Crit Care Med , vol.37 , pp. 951-956
    • Monnet, X.1    Osman, D.2    Ridel, C.3
  • 25
    • 38849093827 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique
    • Costa M.G., Della Rocca G., Chiarandini P., et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2008, 34:257-263.
    • (2008) Intensive Care Med , vol.34 , pp. 257-263
    • Costa, M.G.1    Della Rocca, G.2    Chiarandini, P.3
  • 26
    • 38649127605 scopus 로고    scopus 로고
    • Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting
    • Missant C., Rex S., Wouters P.F. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Eur J Anaesthesiol 2008, 25:243-248.
    • (2008) Eur J Anaesthesiol , vol.25 , pp. 243-248
    • Missant, C.1    Rex, S.2    Wouters, P.F.3
  • 27
    • 24944439222 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement
    • Pittman J., Bar-Yosef S., SumPing J., et al. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 2005, 33:2015-2021.
    • (2005) Crit Care Med , vol.33 , pp. 2015-2021
    • Pittman, J.1    Bar-Yosef, S.2    SumPing, J.3
  • 28
    • 84887731414 scopus 로고    scopus 로고
    • Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
    • Bendjelid K., Marx G., Kiefer N., et al. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients. Br J Anaesth 2013, 111:573-579.
    • (2013) Br J Anaesth , vol.111 , pp. 573-579
    • Bendjelid, K.1    Marx, G.2    Kiefer, N.3
  • 29
    • 34548266524 scopus 로고    scopus 로고
    • Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    • Button D., Weibel L., Reuthebuch O., et al. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007, 99:329-336.
    • (2007) Br J Anaesth , vol.99 , pp. 329-336
    • Button, D.1    Weibel, L.2    Reuthebuch, O.3
  • 30
    • 36649018972 scopus 로고    scopus 로고
    • Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
    • Cannesson M., Attof Y., Rosamel P., et al. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol 2007, 24:832-839.
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 832-839
    • Cannesson, M.1    Attof, Y.2    Rosamel, P.3
  • 31
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • de Waal E.E., Kalkman C.J., Rex S., et al. Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007, 35:1904-1909.
    • (2007) Crit Care Med , vol.35 , pp. 1904-1909
    • de Waal, E.E.1    Kalkman, C.J.2    Rex, S.3
  • 32
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J., Boldt J., Schollhorn T., et al. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007, 98:176-182.
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3
  • 33
    • 62849098504 scopus 로고    scopus 로고
    • Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients
    • Senn A., Button D., Zollinger A., et al. Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients. Crit Care 2009, 13:R32.
    • (2009) Crit Care , vol.13 , pp. R32
    • Senn, A.1    Button, D.2    Zollinger, A.3
  • 34
    • 79960454563 scopus 로고    scopus 로고
    • Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography
    • McLean A.S., Huang S.J., Kot M., et al. Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography. Anaesth Intensive Care 2011, 39:590-598.
    • (2011) Anaesth Intensive Care , vol.39 , pp. 590-598
    • McLean, A.S.1    Huang, S.J.2    Kot, M.3
  • 35
    • 34648831355 scopus 로고    scopus 로고
    • Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform
    • Lorsomradee S., Cromheecke S., De Hert S.G. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. JCardiothorac Vasc Anesth 2007, 21:636-643.
    • (2007) JCardiothorac Vasc Anesth , vol.21 , pp. 636-643
    • Lorsomradee, S.1    Cromheecke, S.2    De Hert, S.G.3
  • 36
    • 57349199888 scopus 로고    scopus 로고
    • Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
    • Biancofiore G., Critchley L.A., Lee A., et al. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth 2009, 102:47-54.
    • (2009) Br J Anaesth , vol.102 , pp. 47-54
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3
  • 37
    • 52149101592 scopus 로고    scopus 로고
    • Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions
    • Della Rocca G., Costa M.G., Chiarandini P., et al. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. JCardiothorac Vasc Anesth 2008, 22:681-687.
    • (2008) JCardiothorac Vasc Anesth , vol.22 , pp. 681-687
    • Della Rocca, G.1    Costa, M.G.2    Chiarandini, P.3
  • 38
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • Biais M., Nouette-Gaulain K., Cottenceau V., et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008, 106:1480-1486.
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 39
    • 77953638305 scopus 로고    scopus 로고
    • Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation
    • Krejci V., Vannucci A., Abbas A., et al. Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation. Liver Transpl 2010, 16:773-782.
    • (2010) Liver Transpl , vol.16 , pp. 773-782
    • Krejci, V.1    Vannucci, A.2    Abbas, A.3
  • 40
    • 80052641970 scopus 로고    scopus 로고
    • Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage
    • Junttila E.K., Koskenkari J.K., Ohtonen P.P., et al. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage. Br J Anaesth 2011, 107:581-586.
    • (2011) Br J Anaesth , vol.107 , pp. 581-586
    • Junttila, E.K.1    Koskenkari, J.K.2    Ohtonen, P.P.3
  • 41
    • 77953245170 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices
    • Monnet X., Anguel N., Naudin B., et al. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care 2010, 14:R109.
    • (2010) Crit Care , vol.14 , pp. R109
    • Monnet, X.1    Anguel, N.2    Naudin, B.3
  • 42
    • 80053301861 scopus 로고    scopus 로고
    • The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal Doppler cardiac output measurements
    • Meng L., Phuong Tran N., Alexander B.S., et al. The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal Doppler cardiac output measurements. Anesth Analg 2011, 113:751-757.
    • (2011) Anesth Analg , vol.113 , pp. 751-757
    • Meng, L.1    Phuong Tran, N.2    Alexander, B.S.3
  • 43
    • 84858433268 scopus 로고    scopus 로고
    • Third-generation FloTrac/Vigileo does not reliably track the changes in cardiac output induced by norepinephrine in critically ill patients
    • Monnet X., Anguel N., Jozwiak M., et al. Third-generation FloTrac/Vigileo does not reliably track the changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth 2012, 108:615-622.
    • (2012) Br J Anaesth , vol.108 , pp. 615-622
    • Monnet, X.1    Anguel, N.2    Jozwiak, M.3
  • 44
    • 80052230646 scopus 로고    scopus 로고
    • Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery
    • Biancofiore G., Critchley L.A., Lee A., et al. Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg 2011, 113:515-522.
    • (2011) Anesth Analg , vol.113 , pp. 515-522
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3
  • 45
    • 84863248542 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device
    • Su B.C., Tsai Y.F., Chen C.Y., et al. Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device. Transplant Proc 2012, 44:424-428.
    • (2012) Transplant Proc , vol.44 , pp. 424-428
    • Su, B.C.1    Tsai, Y.F.2    Chen, C.Y.3
  • 46
    • 84863233378 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation
    • Tsai Y.F., Su B.C., Lin C.C., et al. Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation. Transplant Proc 2012, 44:433-437.
    • (2012) Transplant Proc , vol.44 , pp. 433-437
    • Tsai, Y.F.1    Su, B.C.2    Lin, C.C.3
  • 47
    • 79957512361 scopus 로고    scopus 로고
    • Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy
    • Metzelder S., Coburn M., Fries M., et al. Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy. Br J Anaesth 2011, 106:776-784.
    • (2011) Br J Anaesth , vol.106 , pp. 776-784
    • Metzelder, S.1    Coburn, M.2    Fries, M.3
  • 48
    • 84888291923 scopus 로고    scopus 로고
    • Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach
    • Desebbe O., Henaine R., Keller G., et al. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach. JCardiothorac Vasc Anesth 2013, 27:1122-1127.
    • (2013) JCardiothorac Vasc Anesth , vol.27 , pp. 1122-1127
    • Desebbe, O.1    Henaine, R.2    Keller, G.3
  • 49
    • 84880528583 scopus 로고    scopus 로고
    • Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes
    • Suehiro K., Tanaka K., Funao T., et al. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth 2013, 111:170-177.
    • (2013) Br J Anaesth , vol.111 , pp. 170-177
    • Suehiro, K.1    Tanaka, K.2    Funao, T.3
  • 50
    • 84884212768 scopus 로고    scopus 로고
    • Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease
    • Petzoldt M., Riedel C., Braeunig J., et al. Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease. Intensive Care Med 2013, 39:601-611.
    • (2013) Intensive Care Med , vol.39 , pp. 601-611
    • Petzoldt, M.1    Riedel, C.2    Braeunig, J.3
  • 51
    • 82255192417 scopus 로고    scopus 로고
    • An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation
    • Scolletta S., Franchi F., Taccone F.S., et al. An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Anesth Analg 2011, 113:1389-1395.
    • (2011) Anesth Analg , vol.113 , pp. 1389-1395
    • Scolletta, S.1    Franchi, F.2    Taccone, F.S.3
  • 52
    • 84863096128 scopus 로고    scopus 로고
    • Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output
    • Vasdev S., Chauhan S., Choudhury M., et al. Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output. JClin Monit Comput 2012, 26:115-120.
    • (2012) JClin Monit Comput , vol.26 , pp. 115-120
    • Vasdev, S.1    Chauhan, S.2    Choudhury, M.3
  • 53
    • 77950019418 scopus 로고    scopus 로고
    • Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?
    • Schramm S., Albrecht E., Frascarolo P., et al. Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?. JCardiothorac Vasc Anesth 2010, 24:250-256.
    • (2010) JCardiothorac Vasc Anesth , vol.24 , pp. 250-256
    • Schramm, S.1    Albrecht, E.2    Frascarolo, P.3
  • 54
    • 79952062181 scopus 로고    scopus 로고
    • Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery
    • Broch O., Renner J., Hocker J., et al. Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery. Crit Care 2011, 15:R76.
    • (2011) Crit Care , vol.15 , pp. R76
    • Broch, O.1    Renner, J.2    Hocker, J.3
  • 55
    • 84874382964 scopus 로고    scopus 로고
    • Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ)
    • Nordstrom J., Hallsjo-Sander C., Shore R., et al. Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ). Br J Anaesth 2013, 110:374-380.
    • (2013) Br J Anaesth , vol.110 , pp. 374-380
    • Nordstrom, J.1    Hallsjo-Sander, C.2    Shore, R.3
  • 56
    • 79960547791 scopus 로고    scopus 로고
    • Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients
    • Franchi F., Silvestri R., Cubattoli L., et al. Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients. Br J Anaesth 2011, 107:202-208.
    • (2011) Br J Anaesth , vol.107 , pp. 202-208
    • Franchi, F.1    Silvestri, R.2    Cubattoli, L.3
  • 57
    • 77950020487 scopus 로고    scopus 로고
    • Cardiac index validation using the pressure recording analytic method in unstable patients
    • Zangrillo A., Maj G., Monaco F., et al. Cardiac index validation using the pressure recording analytic method in unstable patients. JCardiothorac Vasc Anesth 2010, 24:265-269.
    • (2010) JCardiothorac Vasc Anesth , vol.24 , pp. 265-269
    • Zangrillo, A.1    Maj, G.2    Monaco, F.3
  • 58
    • 84888299071 scopus 로고    scopus 로고
    • Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery
    • Barile L., Landoni G., Pieri M., et al. Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery. JCardiothorac Vasc Anesth 2013, 27:1108-1113.
    • (2013) JCardiothorac Vasc Anesth , vol.27 , pp. 1108-1113
    • Barile, L.1    Landoni, G.2    Pieri, M.3
  • 59
    • 79952935360 scopus 로고    scopus 로고
    • Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients
    • Paarmann H., Groesdonk H.V., Sedemund-Adib B., et al. Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients. Br J Anaesth 2011, 106:475-481.
    • (2011) Br J Anaesth , vol.106 , pp. 475-481
    • Paarmann, H.1    Groesdonk, H.V.2    Sedemund-Adib, B.3
  • 60
    • 84875363951 scopus 로고    scopus 로고
    • Assessment of volume responsiveness during mechanical ventilation: recent advances
    • Monnet X., Teboul J.L. Assessment of volume responsiveness during mechanical ventilation: recent advances. Crit Care 2013, 17:217.
    • (2013) Crit Care , vol.17 , pp. 217
    • Monnet, X.1    Teboul, J.L.2
  • 61
    • 68149163176 scopus 로고    scopus 로고
    • Acomparison of stroke volume variation measured by the LiDCOplus and FloTrac-Vigileo system
    • de Wilde R.B., Geerts B.F., van den Berg P.C., et al. Acomparison of stroke volume variation measured by the LiDCOplus and FloTrac-Vigileo system. Anaesthesia 2009, 64:1004-1009.
    • (2009) Anaesthesia , vol.64 , pp. 1004-1009
    • de Wilde, R.B.1    Geerts, B.F.2    van den Berg, P.C.3
  • 62
    • 0036217518 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • Pinsky M.R. Functional hemodynamic monitoring. Intensive Care Med 2002, 28:386-388.
    • (2002) Intensive Care Med , vol.28 , pp. 386-388
    • Pinsky, M.R.1
  • 63
    • 84865213001 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices
    • Monnet X., Dres M., Ferre A., et al. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth 2012, 109:330-338.
    • (2012) Br J Anaesth , vol.109 , pp. 330-338
    • Monnet, X.1    Dres, M.2    Ferre, A.3
  • 64
    • 84872741283 scopus 로고    scopus 로고
    • Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine
    • Monnet X., Guerin L., Jozwiak M., et al. Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anaesth 2013, 110:207-213.
    • (2013) Br J Anaesth , vol.110 , pp. 207-213
    • Monnet, X.1    Guerin, L.2    Jozwiak, M.3
  • 65
    • 34548544992 scopus 로고    scopus 로고
    • Limitations of arterial pulse pressure variation and left ventricular stroke volume variation in estimating cardiac pre-load during open heart surgery
    • Rex S., Schalte G., Schroth S., et al. Limitations of arterial pulse pressure variation and left ventricular stroke volume variation in estimating cardiac pre-load during open heart surgery. Acta Anaesthesiol Scand 2007, 51:1258-1267.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 1258-1267
    • Rex, S.1    Schalte, G.2    Schroth, S.3
  • 66
    • 0842284105 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    • Marx G., Cope T., McCrossan L., et al. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesthesiol 2004, 21:132-138.
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 132-138
    • Marx, G.1    Cope, T.2    McCrossan, L.3
  • 67
    • 84878308280 scopus 로고    scopus 로고
    • Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection
    • Vos J.J., Kalmar A.F., Struys M.M., et al. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection. Br J Anaesth 2013, 110:940-946.
    • (2013) Br J Anaesth , vol.110 , pp. 940-946
    • Vos, J.J.1    Kalmar, A.F.2    Struys, M.M.3
  • 68
    • 84885923598 scopus 로고    scopus 로고
    • Comparison of an automated respiratory systolic variation test with dynamic preload indicators to predict fluid responsiveness after major surgery
    • Trepte C.J., Eichhorn V., Haas S.A., et al. Comparison of an automated respiratory systolic variation test with dynamic preload indicators to predict fluid responsiveness after major surgery. Br J Anaesth 2013, 111:736-742.
    • (2013) Br J Anaesth , vol.111 , pp. 736-742
    • Trepte, C.J.1    Eichhorn, V.2    Haas, S.A.3
  • 69
    • 56449113016 scopus 로고    scopus 로고
    • Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    • Biais M., Nouette-Gaulain K., Cottenceau V., et al. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 2008, 101:761-768.
    • (2008) Br J Anaesth , vol.101 , pp. 761-768
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 70
    • 0035080242 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • Berkenstadt H., Margalit N., Hadani M., et al. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001, 92:984-989.
    • (2001) Anesth Analg , vol.92 , pp. 984-989
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3
  • 71
    • 84876542543 scopus 로고    scopus 로고
    • Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position
    • Yang S.Y., Shim J.K., Song Y., et al. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position. Br J Anaesth 2013, 110:713-720.
    • (2013) Br J Anaesth , vol.110 , pp. 713-720
    • Yang, S.Y.1    Shim, J.K.2    Song, Y.3
  • 72
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system
    • Hofer C.K., Senn A., Weibel L., et al. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care 2008, 12:R82.
    • (2008) Crit Care , vol.12 , pp. R82
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3
  • 73
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • Reuter D.A., Kirchner A., Felbinger T.W., et al. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003, 31:1399-1404.
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3
  • 74
    • 71749103572 scopus 로고    scopus 로고
    • Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery
    • Derichard A., Robin E., Tavernier B., et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth 2009, 103:678-684.
    • (2009) Br J Anaesth , vol.103 , pp. 678-684
    • Derichard, A.1    Robin, E.2    Tavernier, B.3
  • 75
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • Hofer C.K., Muller S.M., Furrer L., et al. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005, 128:848-854.
    • (2005) Chest , vol.128 , pp. 848-854
    • Hofer, C.K.1    Muller, S.M.2    Furrer, L.3
  • 76
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • Cannesson M., Musard H., Desebbe O., et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 2009, 108:513-517.
    • (2009) Anesth Analg , vol.108 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3
  • 77
    • 24744434154 scopus 로고    scopus 로고
    • Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
    • Wiesenack C., Fiegl C., Keyser A., et al. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol 2005, 22:658-665.
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 658-665
    • Wiesenack, C.1    Fiegl, C.2    Keyser, A.3
  • 78
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter D.A., Felbinger T.W., Schmidt C., et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002, 28:392-398.
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3
  • 79
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • Biais M., Bernard O., Ha J.C., et al. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth 2010, 104:407-413.
    • (2010) Br J Anaesth , vol.104 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3
  • 80
    • 28844464011 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators
    • Preisman S., Kogan S., Berkenstadt H., et al. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators. Br J Anaesth 2005, 95:746-755.
    • (2005) Br J Anaesth , vol.95 , pp. 746-755
    • Preisman, S.1    Kogan, S.2    Berkenstadt, H.3
  • 82
    • 84055160934 scopus 로고    scopus 로고
    • Passive leg raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance
    • Monnet X., Bleibtreu A., Ferré A., et al. Passive leg raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med 2012, 40:152-157.
    • (2012) Crit Care Med , vol.40 , pp. 152-157
    • Monnet, X.1    Bleibtreu, A.2    Ferré, A.3
  • 83
    • 84884211341 scopus 로고    scopus 로고
    • End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test
    • Monnet X., Bataille A., Magalhaes E., et al. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med 2013, 39:93-100.
    • (2013) Intensive Care Med , vol.39 , pp. 93-100
    • Monnet, X.1    Bataille, A.2    Magalhaes, E.3
  • 84
    • 79953221766 scopus 로고    scopus 로고
    • Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients
    • Monnet X., Jabot J., Maizel J., et al. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med 2011, 39:689-694.
    • (2011) Crit Care Med , vol.39 , pp. 689-694
    • Monnet, X.1    Jabot, J.2    Maizel, J.3
  • 85
    • 84880530079 scopus 로고    scopus 로고
    • End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome
    • Silva S., Jozwiak M., Teboul J.L., et al. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med 2013, 41:1692-1701.
    • (2013) Crit Care Med , vol.41 , pp. 1692-1701
    • Silva, S.1    Jozwiak, M.2    Teboul, J.L.3
  • 86
    • 84855817728 scopus 로고    scopus 로고
    • Clinical review: update on hemodynamic monitoring - a consensus of 16
    • Vincent J.L., Rhodes A., Perel A., et al. Clinical review: update on hemodynamic monitoring - a consensus of 16. Crit Care 2011, 15:229.
    • (2011) Crit Care , vol.15 , pp. 229
    • Vincent, J.L.1    Rhodes, A.2    Perel, A.3
  • 87
    • 84883521100 scopus 로고    scopus 로고
    • Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study
    • Salzwedel C., Puig J., Carstens A., et al. Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study. Crit Care 2013, 17:R191.
    • (2013) Crit Care , vol.17 , pp. R191
    • Salzwedel, C.1    Puig, J.2    Carstens, A.3
  • 88
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    • Benes J., Chytra I., Altmann P., et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care 2010, 14:R118.
    • (2010) Crit Care , vol.14 , pp. R118
    • Benes, J.1    Chytra, I.2    Altmann, P.3
  • 89
    • 79957547490 scopus 로고    scopus 로고
    • Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
    • Cecconi M., Fasano N., Langiano N., et al. Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia. Crit Care 2011, 15:R132.
    • (2011) Crit Care , vol.15 , pp. R132
    • Cecconi, M.1    Fasano, N.2    Langiano, N.3
  • 90
    • 79958110885 scopus 로고    scopus 로고
    • Asystematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • Hamilton M.A., Cecconi M., Rhodes A. Asystematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg 2011, 112:1392-1402.
    • (2011) Anesth Analg , vol.112 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 91
    • 84868379180 scopus 로고    scopus 로고
    • The transpulmonary thermodilution technique
    • Sakka S.G., Reuter D.A., Perel A. The transpulmonary thermodilution technique. JClin Monit Comput 2012, 26:347-353.
    • (2012) JClin Monit Comput , vol.26 , pp. 347-353
    • Sakka, S.G.1    Reuter, D.A.2    Perel, A.3
  • 93
    • 77956931912 scopus 로고    scopus 로고
    • Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
    • Hofhuizen C.M., Lemson J., Hemelaar A.E., et al. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery. Br J Anaesth 2010, 105:493-500.
    • (2010) Br J Anaesth , vol.105 , pp. 493-500
    • Hofhuizen, C.M.1    Lemson, J.2    Hemelaar, A.E.3
  • 94
    • 78049488760 scopus 로고    scopus 로고
    • Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    • Bogert L.W., Wesseling K.H., Schraa O., et al. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia 2010, 65:1119-1125.
    • (2010) Anaesthesia , vol.65 , pp. 1119-1125
    • Bogert, L.W.1    Wesseling, K.H.2    Schraa, O.3
  • 95
    • 79959854628 scopus 로고    scopus 로고
    • Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index
    • Broch O., Bein B., Gruenewald M., et al. Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand 2011, 55:686-693.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 686-693
    • Broch, O.1    Bein, B.2    Gruenewald, M.3
  • 97
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with Nexfin
    • Martina J.R., Westerhof B.E., van Goudoever J., et al. Noninvasive continuous arterial blood pressure monitoring with Nexfin. Anesthesiology 2012, 116(5):1092-1103.
    • (2012) Anesthesiology , vol.116 , Issue.5 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    van Goudoever, J.3
  • 98
    • 80052213181 scopus 로고    scopus 로고
    • Noninvasive continuous or intermittent blood pressure and heart rate patient monitoring in the ED
    • Nowak R.M., Sen A., Garcia A.J., et al. Noninvasive continuous or intermittent blood pressure and heart rate patient monitoring in the ED. Am J Emerg Med 2011, 29:782-789.
    • (2011) Am J Emerg Med , vol.29 , pp. 782-789
    • Nowak, R.M.1    Sen, A.2    Garcia, A.J.3
  • 99
    • 78049508402 scopus 로고    scopus 로고
    • Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology
    • Maggi R., Viscardi V., Furukawa T., et al. Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology. Europace 2010, 12:1616-1622.
    • (2010) Europace , vol.12 , pp. 1616-1622
    • Maggi, R.1    Viscardi, V.2    Furukawa, T.3
  • 100
    • 84867900309 scopus 로고    scopus 로고
    • The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge
    • Monnet X., Picard F., Lidzborski E., et al. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit Care 2012, 16:R212.
    • (2012) Crit Care , vol.16 , pp. R212
    • Monnet, X.1    Picard, F.2    Lidzborski, E.3
  • 101
    • 0015147582 scopus 로고
    • An artificial arterial system for pumping hearts
    • Westerhof N., Elzinga G., Sipkema P. An artificial arterial system for pumping hearts. JAppl Physiol 1971, 31:776-781.
    • (1971) JAppl Physiol , vol.31 , pp. 776-781
    • Westerhof, N.1    Elzinga, G.2    Sipkema, P.3
  • 102
    • 84858342283 scopus 로고    scopus 로고
    • Acomparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery
    • Broch O., Renner J., Gruenewald M., et al. Acomparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia 2012, 67:377-383.
    • (2012) Anaesthesia , vol.67 , pp. 377-383
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 103
    • 84861144517 scopus 로고    scopus 로고
    • Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler
    • Chen G., Meng L., Alexander B., et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler. JClin Anesth 2012, 24:275-283.
    • (2012) JClin Anesth , vol.24 , pp. 275-283
    • Chen, G.1    Meng, L.2    Alexander, B.3
  • 104
    • 84861121516 scopus 로고    scopus 로고
    • Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output
    • van der Spoel A.G., Voogel A.J., Folkers A., et al. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. JClin Anesth 2012, 24:304-309.
    • (2012) JClin Anesth , vol.24 , pp. 304-309
    • van der Spoel, A.G.1    Voogel, A.J.2    Folkers, A.3
  • 105
    • 78650435075 scopus 로고    scopus 로고
    • Comparison of a non-invasive arterial pulse contour technique and echo Doppler aorta velocity-time integral on stroke volume changes in optimization of cardiac resynchronization therapy
    • van Geldorp I.E., Delhaas T., Hermans B., et al. Comparison of a non-invasive arterial pulse contour technique and echo Doppler aorta velocity-time integral on stroke volume changes in optimization of cardiac resynchronization therapy. Europace 2011, 13:87-95.
    • (2011) Europace , vol.13 , pp. 87-95
    • van Geldorp, I.E.1    Delhaas, T.2    Hermans, B.3
  • 106
    • 70449646306 scopus 로고    scopus 로고
    • Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
    • Stover J.F., Stocker R., Lenherr R., et al. Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 2009, 9:6.
    • (2009) BMC Anesthesiol , vol.9 , pp. 6
    • Stover, J.F.1    Stocker, R.2    Lenherr, R.3
  • 107
    • 83155181481 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis
    • Bartels S.A., Stok W.J., Bezemer R., et al. Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis. JClin Monit Comput 2011, 25:315-321.
    • (2011) JClin Monit Comput , vol.25 , pp. 315-321
    • Bartels, S.A.1    Stok, W.J.2    Bezemer, R.3
  • 108
    • 84881370424 scopus 로고    scopus 로고
    • Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output
    • Bubenek-Turconi S.I., Craciun M., Miclea I., et al. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg 2013, 117:366-372.
    • (2013) Anesth Analg , vol.117 , pp. 366-372
    • Bubenek-Turconi, S.I.1    Craciun, M.2    Miclea, I.3
  • 109
    • 84866350766 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery
    • Fischer M.O., Avram R., Carjaliu I., et al. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth 2012, 109(4):514-521.
    • (2012) Br J Anaesth , vol.109 , Issue.4 , pp. 514-521
    • Fischer, M.O.1    Avram, R.2    Carjaliu, I.3
  • 110
    • 84882236591 scopus 로고    scopus 로고
    • Evaluation of cardiac output in intensive care using a non-invasive arterial pulse contour technique (Nexfin(®)) compared with echocardiography
    • Taton O., Fagnoul D., De Backer D., et al. Evaluation of cardiac output in intensive care using a non-invasive arterial pulse contour technique (Nexfin(®)) compared with echocardiography. Anaesthesia 2013, 68:917-923.
    • (2013) Anaesthesia , vol.68 , pp. 917-923
    • Taton, O.1    Fagnoul, D.2    De Backer, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.