메뉴 건너뛰기




Volumn 35, Issue 3, 2009, Pages 498-504

Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique

Author keywords

Cardiovascular monitoring; Methodology; Statistics

Indexed keywords

LITHIUM;

EID: 60449102439     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-008-1292-4     Document Type: Article
Times cited : (76)

References (27)
  • 2
    • 33845321475 scopus 로고    scopus 로고
    • Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]
    • R Pearse D Dawson J Fawcett A Rhodes RM Grounds ED Bennett 2005 Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445] Crit Care 9 R687 R693
    • (2005) Crit Care , vol.9
    • Pearse, R.1    Dawson, D.2    Fawcett, J.3    Rhodes, A.4    Grounds, R.M.5    Bennett, E.D.6
  • 3
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • HJ Swan W Ganz J Forrester H Marcus G Diamond D Chonette 1970 Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter N Engl J Med 283 447 451
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3    Marcus, H.4    Diamond, G.5    Chonette, D.6
  • 7
    • 0027219058 scopus 로고
    • A new method of measuring cardiac output in man using lithium dilution
    • RA Linton DM Band KM Haire 1993 A new method of measuring cardiac output in man using lithium dilution Br J Anaesth 71 262 266
    • (1993) Br J Anaesth , vol.71 , pp. 262-266
    • Linton, R.A.1    Band, D.M.2    Haire, K.M.3
  • 8
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • JM Bland DG Altman 1999 Measuring agreement in method comparison studies Stat Methods Med Res 8 135 160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0022617227 scopus 로고
    • Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
    • JR Jansen A Versprille 1986 Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation Intensive Care Med 12 71 79
    • (1986) Intensive Care Med , vol.12 , pp. 71-79
    • Jansen, J.R.1    Versprille, A.2
  • 16
    • 0029153813 scopus 로고
    • The thermodilution method for the clinical assessment of cardiac output
    • JR Jansen 1995 The thermodilution method for the clinical assessment of cardiac output Intensive Care Med 21 691 697
    • (1995) Intensive Care Med , vol.21 , pp. 691-697
    • Jansen, J.R.1
  • 17
    • 0036785350 scopus 로고    scopus 로고
    • Thermodilution cardiac output. Cold vs room temperature injectate and the importance of measuring the injectate temperature in the right atrium
    • PG Berthelsen N Eldrup LB Nilsson JP Rasmussen 2002 Thermodilution cardiac output. Cold vs room temperature injectate and the importance of measuring the injectate temperature in the right atrium Acta Anaesthesiol Scand 46 1103 1110
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 1103-1110
    • Berthelsen, P.G.1    Eldrup, N.2    Nilsson, L.B.3    Rasmussen, J.P.4
  • 20
    • 2942564478 scopus 로고    scopus 로고
    • Equipment review: An appraisal of the LiDCO plus method of measuring cardiac output
    • RM Pearse K Ikram J Barry 2004 Equipment review: an appraisal of the LiDCO plus method of measuring cardiac output Crit Care 8 190 195
    • (2004) Crit Care , vol.8 , pp. 190-195
    • Pearse, R.M.1    Ikram, K.2    Barry, J.3
  • 22
    • 0036014538 scopus 로고    scopus 로고
    • Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: An indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output
    • MM Jonas SJ Tanser 2002 Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output Curr Opin Crit Care 8 257 261
    • (2002) Curr Opin Crit Care , vol.8 , pp. 257-261
    • Jonas, M.M.1    Tanser, S.J.2
  • 23
    • 0033503137 scopus 로고    scopus 로고
    • A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride
    • MM Jonas FE Kelly RA Linton DM Band TK O'Brien NW Linton 1999 A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride J Clin Monit Comput 15 525 528
    • (1999) J Clin Monit Comput , vol.15 , pp. 525-528
    • Jonas, M.M.1    Kelly, F.E.2    Linton, R.A.3    Band, D.M.4    O'Brien, T.K.5    Linton, N.W.6
  • 26
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • LA Critchley JA Critchley 1999 A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 85 91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 27
    • 34249000391 scopus 로고    scopus 로고
    • Methodologies for assessing agreement between two methods of clinical measurement: Are we as good as we think we are?
    • M Cecconi M Grounds A Rhodes 2007 Methodologies for assessing agreement between two methods of clinical measurement: are we as good as we think we are? Curr Opin Crit Care 13 294 296
    • (2007) Curr Opin Crit Care , vol.13 , pp. 294-296
    • Cecconi, M.1    Grounds, M.2    Rhodes, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.