메뉴 건너뛰기




Volumn 25, Issue 3, 2008, Pages 243-248

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO™) and Doppler echocardiography during off-pump coronary artery bypass grafting

Author keywords

Cardiac output; Coronary artery bypass grafting; Coronary artery bypass off pump; Physiologic monitoring; Surgery cardiac

Indexed keywords

DOBUTAMINE; LORAZEPAM; MIDAZOLAM; PANCURONIUM; PROPOFOL; SUFENTANIL;

EID: 38649127605     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1017/S0265021507002979     Document Type: Article
Times cited : (37)

References (25)
  • 2
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors Jr AF, Speroff T, Dawson NV et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996; 276: 889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors Jr, A.F.1    Speroff, T.2    Dawson, N.V.3
  • 3
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003; 348: 5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 4
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005; 366: 472-477.
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 5
    • 33646898476 scopus 로고    scopus 로고
    • Clinical outcomes of low-risk patients undergoing beating-heart surgery with or without pulmonary artery catheterization
    • Resano FG, Kapetanakis EI, Hill PC, Haile E, Corso PJ. Clinical outcomes of low-risk patients undergoing beating-heart surgery with or without pulmonary artery catheterization. J Cardiothorac Vasc Anesth 2006; 20: 300-306.
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 300-306
    • Resano, F.G.1    Kapetanakis, E.I.2    Hill, P.C.3    Haile, E.4    Corso, P.J.5
  • 6
    • 33646949522 scopus 로고    scopus 로고
    • Clinical outcomes in patients undergoing elective coronary artery bypass graft surgery with and without utilization of pulmonary artery catheter-generated data
    • Djaiani G, Karski J, Yudin M et al. Clinical outcomes in patients undergoing elective coronary artery bypass graft surgery with and without utilization of pulmonary artery catheter-generated data. J Cardiothorac Vasc Anesth 2006; 20: 307-310.
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 307-310
    • Djaiani, G.1    Karski, J.2    Yudin, M.3
  • 7
    • 0032817727 scopus 로고    scopus 로고
    • Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    • Buhre W, Weyland A, Kazmaier S et al. Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1999; 13: 437-440.
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 437-440
    • Buhre, W.1    Weyland, A.2    Kazmaier, S.3
  • 8
    • 17444415335 scopus 로고    scopus 로고
    • Cardiac output monitoring using a brachial arterial catheter during off-pump coronary artery bypass grafting
    • Wouters PF, Quaghebeur B, Sergeant P et al. Cardiac output monitoring using a brachial arterial catheter during off-pump coronary artery bypass grafting. J Cardiothorac Vasc Anesth 2005; 19: 160-164.
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , pp. 160-164
    • Wouters, P.F.1    Quaghebeur, B.2    Sergeant, P.3
  • 9
    • 0346099351 scopus 로고    scopus 로고
    • A comparison of CardioQ and thermodilution cardiac output during off-pump coronary artery surgery
    • Hullett B, Gibbs N, Weightman W, Thackray M, Newman M. A comparison of CardioQ and thermodilution cardiac output during off-pump coronary artery surgery. J Cardiothorac Vasc Anesth 2003; 17: 728-732.
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 728-732
    • Hullett, B.1    Gibbs, N.2    Weightman, W.3    Thackray, M.4    Newman, M.5
  • 10
    • 10044230318 scopus 로고    scopus 로고
    • Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution
    • Bettex DA, Hinselmann V, Hellermann JP, Janni R, Schmid ER. Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution. Anaesthesia 2004; 59: 1184-1192S.
    • (2004) Anaesthesia , vol.59
    • Bettex, D.A.1    Hinselmann, V.2    Hellermann, J.P.3    Janni, R.4    Schmid, E.R.5
  • 11
    • 0027515924 scopus 로고
    • Transgastric continuous-wave Doppler to determine cardiac output
    • Katz WE, Gasior TA, Quinlan JJ, Gorcsan 3rd J. Transgastric continuous-wave Doppler to determine cardiac output. Am J Cardiol 1993; 71: 853-857.
    • (1993) Am J Cardiol , vol.71 , pp. 853-857
    • Katz, W.E.1    Gasior, T.A.2    Quinlan, J.J.3    Gorcsan 3rd, J.4
  • 12
    • 0028355287 scopus 로고
    • Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve
    • Darmon PL, Hillel Z, Mogtader A, Mindich B, Thys D. Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve. Anesthesiology 1994; 80: 796-805.
    • (1994) Anesthesiology , vol.80 , pp. 796-805
    • Darmon, P.L.1    Hillel, Z.2    Mogtader, A.3    Mindich, B.4    Thys, D.5
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 15
    • 0036744725 scopus 로고    scopus 로고
    • Cardiac output measurement during cardiac surgery: Esophageal Doppler versus pulmonary artery catheter
    • Su NY, Huang CJ, Tsai P, Hsu YW, Hung YC, Cheng CR. Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter. Acta Anaesthesiol Sin 2002; 40: 127-133.
    • (2002) Acta Anaesthesiol Sin , vol.40 , pp. 127-133
    • Su, N.Y.1    Huang, C.J.2    Tsai, P.3    Hsu, Y.W.4    Hung, Y.C.5    Cheng, C.R.6
  • 16
    • 1942454804 scopus 로고    scopus 로고
    • Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output
    • Bein B, Worthmann F, Tonner PH et al. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output. J Cardiothorac Vasc Anesth 2004; 18: 185-189.
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , pp. 185-189
    • Bein, B.1    Worthmann, F.2    Tonner, P.H.3
  • 17
    • 33748923649 scopus 로고    scopus 로고
    • Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery
    • Halvorsen PS, Espinoza A, Lundblad R et al. Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery. Acta Anaesthesiol Scand 2006; 50: 1050-1057.
    • (2006) Acta Anaesthesiol Scand , vol.50 , pp. 1050-1057
    • Halvorsen, P.S.1    Espinoza, A.2    Lundblad, R.3
  • 19
    • 0038110704 scopus 로고    scopus 로고
    • Relationship between aortic-to-radial arterial pressure gradient after cardiopulmonary bypass and changes in arterial elasticity
    • Kanazawa M, Fukuyama H, Kinefuchi Y, Takiguchi M, Suzuki T. Relationship between aortic-to-radial arterial pressure gradient after cardiopulmonary bypass and changes in arterial elasticity. Anesthesiology 2003; 99: 48-53.
    • (2003) Anesthesiology , vol.99 , pp. 48-53
    • Kanazawa, M.1    Fukuyama, H.2    Kinefuchi, Y.3    Takiguchi, M.4    Suzuki, T.5
  • 20
    • 21244503107 scopus 로고    scopus 로고
    • Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB
    • Yamashita K, Nishiyama T, Yokoyama T, Abe H, Manabe M. Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB. Can J Anaesth 2005; 52: 530-534.
    • (2005) Can J Anaesth , vol.52 , pp. 530-534
    • Yamashita, K.1    Nishiyama, T.2    Yokoyama, T.3    Abe, H.4    Manabe, M.5
  • 21
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982; 126: 1001-1004.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 22
    • 0030757635 scopus 로고    scopus 로고
    • Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution
    • Estagnasie P, Djedaini K, Mier L, Coste F, Dreyfuss D. Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution. Intensive Care Med 1997; 23: 753-759.
    • (1997) Intensive Care Med , vol.23 , pp. 753-759
    • Estagnasie, P.1    Djedaini, K.2    Mier, L.3    Coste, F.4    Dreyfuss, D.5
  • 23
    • 0035064663 scopus 로고    scopus 로고
    • Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb
    • Linton NW, Linton RA. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001; 86: 486-496.
    • (2001) Br J Anaesth , vol.86 , pp. 486-496
    • Linton, N.W.1    Linton, R.A.2
  • 25
    • 0030832772 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A comparison with thermodilution
    • Linton R, Band D, O'Brien T, Jonas MM, Linton NW. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med 1997; 25: 1796-1800.
    • (1997) Crit Care Med , vol.25 , pp. 1796-1800
    • Linton, R.1    Band, D.2    O'Brien, T.3    Jonas, M.M.4    Linton, N.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.