Volumn 110, Issue 5, 2013, Pages 713-720

Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position

Author keywords

fluids, i.v.; heart, cardiac output; monitoring, arterial pressure; position, prone

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSTURE; CLINICAL ARTICLE; CLINICAL TRIAL; CORRECTED FLOW TIME; FEMALE; FLUID THERAPY; HEART PRELOAD; HEART STROKE VOLUME; HUMAN; MALE; PREDICTIVE VALIDITY; PREDICTOR VARIABLE; PRIORITY JOURNAL; PROSPECTIVE STUDY; PULSE PRESSURE; PULSE PRESSURE VARIATION; SENSITIVITY AND SPECIFICITY; SPINE FUSION; SPINE SURGERY; SUPINE POSITION; VALIDATION STUDY;

EID: 84876542543     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aes475     Document Type: Article
Times cited : (61)

References (30)
  • 1
    • 12144287425 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
    • Kumar A, Anel R, Bunnell E, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32: 691-9
    • (2004) Crit Care Med , vol.32 , pp. 691-699
    • Kumar, A.1    Anel, R.2    Bunnell, E.3
  • 2
    • 71749103572 scopus 로고    scopus 로고
    • Automated pulse pressure and stroke volume variations from radial artery: Evaluation during major abdominal surgery
    • Derichard A, Robin E, Tavernier B, et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth 2009; 103: 678-84
    • (2009) Br J Anaesth , vol.103 , pp. 678-684
    • Derichard, A.1    Robin, E.2    Tavernier, B.3
  • 3
    • 67849114322 scopus 로고    scopus 로고
    • A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography
    • Biais M, Nouette-Gaulain K, Roullet S, Quinart A, Revel P, Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiography. Anesth Analg 2009; 109: 466-9
    • (2009) Anesth Analg , vol.109 , pp. 466-469
    • Biais, M.1    Nouette-Gaulain, K.2    Roullet, S.3    Quinart, A.4    Revel, P.5    Sztark, F.6
  • 4
    • 27744442396 scopus 로고    scopus 로고
    • Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery
    • Wakeling HG, McFall MR, Jenkins CS, et al. Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. Br J Anaesth 2005; 95: 634-42
    • (2005) Br J Anaesth , vol.95 , pp. 634-642
    • Wakeling, H.G.1    McFall, M.R.2    Jenkins, C.S.3
  • 5
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, et al. Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007; 99: 343-8
    • (2007) Br J Anaesth , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3
  • 6
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • quiz 49-5
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103: 419-28; quiz 49-5
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 7
    • 2942683043 scopus 로고    scopus 로고
    • Effects of mid-line thoracotomy on the interaction between mechanical ventilation and cardiac filling during cardiac surgery
    • Reuter DA, Goresch T, Goepfert MS, Wildhirt SM, Kilger E, Goetz AE. Effects of mid-line thoracotomy on the interaction between mechanical ventilation and cardiac filling during cardiac surgery. Br J Anaesth 2004; 92: 808-13
    • (2004) Br J Anaesth , vol.92 , pp. 808-813
    • Reuter, D.A.1    Goresch, T.2    Goepfert, M.S.3    Wildhirt, S.M.4    Kilger, E.5    Goetz, A.E.6
  • 8
    • 77951205433 scopus 로고    scopus 로고
    • The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness
    • Muller L, Louart G, Bousquet PJ, et al. The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med 2010; 36: 496-503
    • (2010) Intensive Care Med , vol.36 , pp. 496-503
    • Muller, L.1    Louart, G.2    Bousquet, P.J.3
  • 9
    • 54549110342 scopus 로고    scopus 로고
    • Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation
    • Kim HK, Pinsky MR. Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation. Crit Care Med 2008; 36: 2858-62
    • (2008) Crit Care Med , vol.36 , pp. 2858-2862
    • Kim, H.K.1    Pinsky, M.R.2
  • 10
    • 0025995952 scopus 로고
    • Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects
    • Singer M, Allen MJ, Webb AR, Bennett ED. Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 1991; 19: 1138-45
    • (1991) Crit Care Med , vol.19 , pp. 1138-1145
    • Singer, M.1    Allen, M.J.2    Webb, A.R.3    Bennett, E.D.4
  • 11
    • 33744819988 scopus 로고    scopus 로고
    • Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: An echocardiographic study
    • discussion 94
    • Dharmavaram S, Jellish WS, Nockels RP, et al. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine (Phila Pa 1976) 2006; 31: 1388-93; discussion 94
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 1388-1393
    • Dharmavaram, S.1    Jellish, W.S.2    Nockels, R.P.3
  • 13
    • 0036792321 scopus 로고    scopus 로고
    • Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery
    • Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 2002; 97: 820-6
    • (2002) Anesthesiology , vol.97 , pp. 820-826
    • Gan, T.J.1    Soppitt, A.2    Maroof, M.3
  • 14
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. Br Med J 1997; 315: 909-12
    • (1997) Br Med J , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 15
    • 84856769201 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in septic shock patients: Comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    • Khwannimit B, Bhurayanontachai R. Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation. Eur J Anaesthesiol 2012; 29: 64-9
    • (2012) Eur J Anaesthesiol , vol.29 , pp. 64-69
    • Khwannimit, B.1    Bhurayanontachai, R.2
  • 16
    • 80054862153 scopus 로고    scopus 로고
    • Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume
    • Mesquida J, Kim HK, Pinsky MR. Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med 2011; 37: 1672-9
    • (2011) Intensive Care Med , vol.37 , pp. 1672-1679
    • Mesquida, J.1    Kim, H.K.2    Pinsky, M.R.3
  • 17
    • 84860157495 scopus 로고    scopus 로고
    • Functional haemodynamic monitoring: The value of SVV as measured by the LiDCORapid in predicting fluid responsiveness in high risk vascular surgical patients
    • Willars C, Dada A, Hughes T, Green D. Functional haemodynamic monitoring: the value of SVV as measured by the LiDCORapid in predicting fluid responsiveness in high risk vascular surgical patients. Int J Surg 2012; 10: 148-52
    • (2012) Int J Surg , vol.10 , pp. 148-152
    • Willars, C.1    Dada, A.2    Hughes, T.3    Green, D.4
  • 18
    • 79959854628 scopus 로고    scopus 로고
    • Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index
    • Broch O, Bein B, Gruenewald M, et al. Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand 2011; 55: 686-93
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 686-693
    • Broch, O.1    Bein, B.2    Gruenewald, M.3
  • 19
    • 78651494522 scopus 로고    scopus 로고
    • Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: An experimental study
    • Jacques D, Bendjelid K, Duperret S, Colling J, Piriou V, Viale JP. Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study. Crit Care 2011; 15: R33
    • (2011) Crit Care , vol.15
    • Jacques, D.1    Bendjelid, K.2    Duperret, S.3    Colling, J.4    Piriou, V.5    Viale, J.P.6
  • 20
    • 64149097210 scopus 로고    scopus 로고
    • Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    • Renner J, Gruenewald M, Quaden R, et al. Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med 2009; 37: 650-8
    • (2009) Crit Care Med , vol.37 , pp. 650-658
    • Renner, J.1    Gruenewald, M.2    Quaden, R.3
  • 21
    • 33846284531 scopus 로고    scopus 로고
    • Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs
    • Duperret S, Lhuillier F, Piriou V, et al. Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs. Intensive Care Med 2007; 33: 163-71
    • (2007) Intensive Care Med , vol.33 , pp. 163-171
    • Duperret, S.1    Lhuillier, F.2    Piriou, V.3
  • 22
    • 25144499106 scopus 로고    scopus 로고
    • Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    • Monnet X, Rienzo M, Osman D, et al. Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med 2005; 31: 1195-201
    • (2005) Intensive Care Med , vol.31 , pp. 1195-1201
    • Monnet, X.1    Rienzo, M.2    Osman, D.3
  • 23
    • 36849055073 scopus 로고    scopus 로고
    • Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery
    • Abbas SM, Hill AG. Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 2008; 63: 44-51
    • (2008) Anaesthesia , vol.63 , pp. 44-51
    • Abbas, S.M.1    Hill, A.G.2
  • 26
    • 69349094653 scopus 로고    scopus 로고
    • Assessing fluid responsiveness in critically ill patients: False-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle
    • Mahjoub Y, Pila C, Friggeri A, et al. Assessing fluid responsiveness in critically ill patients: false-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle. Crit Care Med 2009; 37: 2570-5
    • (2009) Crit Care Med , vol.37 , pp. 2570-2575
    • Mahjoub, Y.1    Pila, C.2    Friggeri, A.3
  • 27
    • 69349104951 scopus 로고    scopus 로고
    • Preload responsiveness or right ventricular dysfunction
    • Vieillard-Baron A, Charron C. Preload responsiveness or right ventricular dysfunction? Crit Care Med 2009; 37: 2662-3.
    • (2009) Crit Care Med , vol.37 , pp. 2662-2663
    • Vieillard-Baron, A.1    Charron, C.2
  • 28
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth 2010; 104: 407-13
    • (2010) Br J Anaesth , vol.104 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3    Degryse, C.4    Sztark, F.5
  • 30
    • 33749254838 scopus 로고    scopus 로고
    • Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume
    • Gunn SR, Kim HK, Harrigan PW, Pinsky MR. Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume. Intensive Care Med 2006; 32: 1537-46
    • (2006) Intensive Care Med , vol.32 , pp. 1537-1546
    • Gunn, S.R.1    Kim, H.K.2    Harrigan, P.W.3    Pinsky, M.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.