메뉴 건너뛰기




Volumn 44, Issue 2, 2012, Pages 424-428

Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: Validity of a third-generation device

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTERIAL PRESSURE; ARTICLE; CLINICAL ARTICLE; FEMALE; HEART OUTPUT; HEMODYNAMIC MONITORING; HUMAN; LIVER TRANSPLANTATION; MALE; MEASUREMENT ERROR; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; SYSTEMIC VASCULAR RESISTANCE; THERMODILUTION; WAVEFORM;

EID: 84863248542     PISSN: 00411345     EISSN: 18732623     Source Type: Journal    
DOI: 10.1016/j.transproceed.2011.12.036     Document Type: Article
Times cited : (31)

References (22)
  • 1
    • 48949120197 scopus 로고    scopus 로고
    • Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation
    • B.C. Su, H.P. Yu, M.W. Yang Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation Liver Transpl 14 2008 1029
    • (2008) Liver Transpl , vol.14 , pp. 1029
    • Su, B.C.1    Yu, H.P.2    Yang, M.W.3
  • 2
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • J. Mayer, J. Boldt, T. Schollhorn Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery Br J Anaesth 98 2007 176
    • (2007) Br J Anaesth , vol.98 , pp. 176
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3
  • 3
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac cardiac output monitoring system
    • H.I. Opdam, L. Wan, R. Bellomo A pilot assessment of the FloTrac cardiac output monitoring system Intensive Care Med 33 2007 344
    • (2007) Intensive Care Med , vol.33 , pp. 344
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3
  • 4
    • 84863239952 scopus 로고    scopus 로고
    • Evaluation of an uncalibrated arterial pulse contour cardiac output monitor system in cirrhotic patients undergoing liver surgery
    • G. Biancofiore, L.A.H. Critchley, A. Lee Evaluation of an uncalibrated arterial pulse contour cardiac output monitor system in cirrhotic patients undergoing liver surgery Br J Anaesth 103 2009 185
    • (2009) Br J Anaesth , vol.103 , pp. 185
    • Biancofiore, G.1    Critchley, L.A.H.2    Lee, A.3
  • 5
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • B. Matthieu, N.G. Karine, C. Vincent Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis Anesth Analg 106 2008 1480
    • (2008) Anesth Analg , vol.106 , pp. 1480
    • Matthieu, B.1    Karine, N.G.2    Vincent, C.3
  • 6
    • 77953638305 scopus 로고    scopus 로고
    • Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation
    • V. Krejci, A. Vannucci, A. Abbas Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation Liver Transpl 16 2010 773
    • (2010) Liver Transpl , vol.16 , pp. 773
    • Krejci, V.1    Vannucci, A.2    Abbas, A.3
  • 7
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients
    • D. De Backer, G. Marx, A. Tan Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients Intensive Care Med 37 2011 233
    • (2011) Intensive Care Med , vol.37 , pp. 233
    • De Backer, D.1    Marx, G.2    Tan, A.3
  • 8
    • 70450224488 scopus 로고    scopus 로고
    • The accuracy of the Vigileo/FloTrac system has been improvedfollow-up after a software update: A blinded comparative study of 30 cardiosurgical patients
    • A. Zimmermann, J. Steinwedner, S. Hofbauer The accuracy of the Vigileo/FloTrac system has been improvedfollow-up after a software update: a blinded comparative study of 30 cardiosurgical patients J Cardiothorac Vasc Anesth 19 2009 929
    • (2009) J Cardiothorac Vasc Anesth , vol.19 , pp. 929
    • Zimmermann, A.1    Steinwedner, J.2    Hofbauer, S.3
  • 9
    • 70449475939 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform
    • J. Mayer, S. Suttner Cardiac output derived from arterial pressure waveform Curr Opin Anaesthesiol 22 2009 804
    • (2009) Curr Opin Anaesthesiol , vol.22 , pp. 804
    • Mayer, J.1    Suttner, S.2
  • 10
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • L. Lin A concordance correlation coefficient to evaluate reproducibility Biometrics 45 1989 255
    • (1989) Biometrics , vol.45 , pp. 255
    • Lin, L.1
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J.M. Bland, D.G. Altman Measuring agreement in method comparison studies Stat Methods Med Res 8 1999 135
    • (1999) Stat Methods Med Res , vol.8 , pp. 135
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 34548208591 scopus 로고    scopus 로고
    • Using the Bland-Altman method to measure agreement with repeated measures
    • P.S. Myles, J. Cui Using the Bland-Altman method to measure agreement with repeated measures Br J Anaesth 99 2007 309
    • (2007) Br J Anaesth , vol.99 , pp. 309
    • Myles, P.S.1    Cui, J.2
  • 13
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • L.A. Critchley, J.A. Critchley A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 1999 85
    • (1999) J Clin Monit Comput , vol.15 , pp. 85
    • Critchley, L.A.1    Critchley, J.A.2
  • 14
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac cardiac output monitoring system
    • H.I. Opdam, L. Wan, R. Bellmo A pilot assessment of the FloTrac cardiac output monitoring system Intensive Care Med 33 2007 344
    • (2007) Intensive Care Med , vol.33 , pp. 344
    • Opdam, H.I.1    Wan, L.2    Bellmo, R.3
  • 15
    • 65649112876 scopus 로고    scopus 로고
    • Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: A review and meta-analysis
    • J. Mayer, J. Boldt, R. Poland Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis J Cardiothorac Vasc Anesth 23 2009 401
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 401
    • Mayer, J.1    Boldt, J.2    Poland, R.3
  • 16
    • 79957512361 scopus 로고    scopus 로고
    • Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy
    • S. Metzelder, M. Coburn, M. Fries Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy Br J Anaesth 106 2011 776
    • (2011) Br J Anaesth , vol.106 , pp. 776
    • Metzelder, S.1    Coburn, M.2    Fries, M.3
  • 17
    • 33644892769 scopus 로고    scopus 로고
    • Cardiopulmonary complications in chronic liver disease
    • S. Moller, J.H. Henriksen Cardiopulmonary complications in chronic liver disease World J Gastroenterol 12 2005 526
    • (2005) World J Gastroenterol , vol.12 , pp. 526
    • Moller, S.1    Henriksen, J.H.2
  • 18
    • 0036920202 scopus 로고    scopus 로고
    • Hyperdynamic circulation in liver cirrhosis: Not peripheral vasodilatation but "splanchnic steal
    • D.E. Newby, P.C. Hayes Hyperdynamic circulation in liver cirrhosis: not peripheral vasodilatation but "splanchnic steal" QJM 95 2002 827
    • (2002) QJM , vol.95 , pp. 827
    • Newby, D.E.1    Hayes, P.C.2
  • 19
    • 77950019418 scopus 로고    scopus 로고
    • Validity of an arterial pressure waveform analysis device: Does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?
    • S. Schramm, E. Alvrecht, P. Frascarolo Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements? J Cardiothorac Vasc Anesth 24 2010 250
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 250
    • Schramm, S.1    Alvrecht, E.2    Frascarolo, P.3
  • 20
    • 77950022940 scopus 로고    scopus 로고
    • Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: An evaluation in cardiac surgery patients
    • C.K. Hofer, D. Button, L. Weibel Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients J Cardiothorac Vasc Anesth 24 2010 257
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 257
    • Hofer, C.K.1    Button, D.2    Weibel, L.3
  • 21
    • 22944441604 scopus 로고    scopus 로고
    • Radial to femoral arterial blood pressure differences during liver transplantation
    • D. Arnal, I. Garutti, J. Perez-Pena Radial to femoral arterial blood pressure differences during liver transplantation Anaesthesia 60 2005 766
    • (2005) Anaesthesia , vol.60 , pp. 766
    • Arnal, D.1    Garutti, I.2    Perez-Pena, J.3
  • 22
    • 77949730294 scopus 로고    scopus 로고
    • Assessment of a cardiac output devise using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution
    • J.B. Hamm, B.V. Nguyen, G. Kiss Assessment of a cardiac output devise using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution Anaesth Intensive Care 38 2010 295
    • (2010) Anaesth Intensive Care , vol.38 , pp. 295
    • Hamm, J.B.1    Nguyen, B.V.2    Kiss, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.