메뉴 건너뛰기




Volumn 25, Issue 5, 2011, Pages 315-321

Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis

Author keywords

Cardiac output; Exercise; Hemodynamic monitoring; Innocor; Nexfin; Pulmonary blood flow; Pulse contour analysis; Respired gas analysis; Volume clamp plethysmography

Indexed keywords

CARDIAC OUTPUT; EXERCISE; INNOCOR; NEXFIN; PULMONARY BLOOD FLOW; PULSE-CONTOUR ANALYSIS;

EID: 83155181481     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-011-9310-4     Document Type: Article
Times cited : (38)

References (31)
  • 1
    • 27444433897 scopus 로고    scopus 로고
    • Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation [1]
    • DOI 10.1016/j.jacc.2005.08.005, PII S0735109705017924
    • Agostoni P, Cattadori G, Apostolo A, Contini M, Palermo P, Marenzi G, Wasserman K. Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 2005; 46(9): 1779-1781. (Pubitemid 41531639)
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.9 , pp. 1779-1781
    • Agostoni, P.1    Cattadori, G.2    Apostolo, A.3    Contini, M.4    Palermo, P.5    Marenzi, G.6    Wasserman, K.7
  • 2
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970; 283(9): 447-451.
    • (1970) N Engl J Med , vol.283 , Issue.9 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3    Marcus, H.4    Diamond, G.5    Chonette, D.6
  • 3
    • 0002049738 scopus 로고
    • Über die Messung des Blutquantums in den Herzventrikeln
    • Fick A. Über die Messung des Blutquantums in den Herzventrikeln. Sitzung Phys med Gesell Würzburg 1870; 14-16.
    • (1870) Sitzung Phys Med Gesell Würzburg , pp. 14-16
    • Fick, A.1
  • 4
    • 78650833522 scopus 로고    scopus 로고
    • Cardiac output monitoring: Is there a gold standard and how do the newer technologies compare?
    • Pugsley J, Lerner AB. Cardiac output monitoring: is there a gold standard and how do the newer technologies compare?. Semin Cardiothorac Vasc Anesth 2010; 14(4): 274-282.
    • (2010) Semin Cardiothorac Vasc Anesth , vol.14 , Issue.4 , pp. 274-282
    • Pugsley, J.1    Lerner, A.B.2
  • 6
    • 0036345861 scopus 로고    scopus 로고
    • Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output
    • Remmen JJ, Aengevaeren WR, Verheugt FW, van ver Werf T, Luijten HE, Bos A, Jansen RW. Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output. Clin Sci (Lond) 2002; 103(2): 143-149.
    • (2002) Clin Sci (Lond) , vol.103 , Issue.2 , pp. 143-149
    • Remmen, J.J.1    Aengevaeren, W.R.2    Verheugt, F.W.3    Van Ver Werf, T.4    Luijten, H.E.5    Bos, A.6    Jansen, R.W.7
  • 8
    • 0033035143 scopus 로고    scopus 로고
    • 2 rebreathing
    • DOI 10.1046/j.1365-2281.1999.00166.x
    • Houtman S, Oeseburg B, Hopman MT. Non-invasive cardiac output assessment during moderate exercise: pulse contour compared with CO2 rebreathing. Clin Physiol 1999; 19(3): 230-237. (Pubitemid 29248551)
    • (1999) Clinical Physiology , vol.19 , Issue.3 , pp. 230-237
    • Houtman, S.1    Oeseburg, B.2    Hopman, M.T.E.3
  • 9
    • 2142713077 scopus 로고    scopus 로고
    • Correction of cardiac output obtained by Modelflow® from finger pulse pressure profiles with a respiratory method in humans
    • DOI 10.1042/CS20030302
    • Tam E, Azabji Kenfack M, Cautero M, Lador F, Antonutto G, di Prampero PE, Ferretti G, Capelli C. Correction of cardiac output obtained by Modelflow from finger pulse pressure profiles with a respiratory method in humans. Clin Sci 2004; 106(4): 371-376. (Pubitemid 38553584)
    • (2004) Clinical Science , vol.106 , Issue.4 , pp. 371-376
    • Tam, E.1    Azabji Kenfack, M.2    Cautero, M.3    Lador, F.4    Antonutto, G.5    Di Prampero, P.E.6    Ferretti, G.7    Capelli, C.8
  • 10
    • 2142700056 scopus 로고    scopus 로고
    • Cardiac output by Modelflow® method from intra-arterial and fingertip pulse pressure profiles
    • DOI 10.1042/CS20030303
    • Azabji Kenfack M, Lador F, Licker M, Moia C, Tam E, Capelli C, Morel D, Ferretti G. Cardiac output by Modelflow method from intra-arterial and fingertip pulse pressure profiles. Clin Sci 2004; 106(4): 365-369. (Pubitemid 38553583)
    • (2004) Clinical Science , vol.106 , Issue.4 , pp. 365-369
    • Azabji Kenfack, M.1    Lador, F.2    Licker, M.3    Moia, C.4    Tam, E.5    Capelli, C.6    Morel, D.7    Ferretti, G.8
  • 12
    • 0030991029 scopus 로고    scopus 로고
    • Cardiac output estimated noninvasively from oxygen uptake during exercise
    • Stringer WW, Hansen JE, Wasserman K. Cardiac output estimated noninvasively from oxygen uptake during exercise. J Appl Physiol 1997; 82(3): 908-912. (Pubitemid 27123273)
    • (1997) Journal of Applied Physiology , vol.82 , Issue.3 , pp. 908-912
    • Stringer, W.W.1    Hansen, J.E.2    Wasserman, K.3
  • 13
    • 0026436852 scopus 로고
    • Criteria for set point estimation in the volume clamp method of blood pressure measurement
    • Penáz J. Criteria for set point estimation in the volume clamp method of blood pressure measurement. Physiol Res 1992; 41(1): 5-10.
    • (1992) Physiol Res , vol.41 , Issue.1 , pp. 5-10
    • Penáz, J.1
  • 16
    • 0033974708 scopus 로고    scopus 로고
    • Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow
    • Christensen P, Clemensen P, Andersen PK, Henneberg SW. Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow. Crit Care Med 2000; 28(1): 51-56. (Pubitemid 30091028)
    • (2000) Critical Care Medicine , vol.28 , Issue.1 , pp. 51-56
    • Christensen, P.1    Clemensen, P.2    Andersen, P.K.3    Henneberg, S.W.4
  • 17
    • 0017362189 scopus 로고
    • Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements
    • Triebwasser JH, Johnson RI, Burpo RP, Campbell JC, Reardon WC, Blomqvist CG. Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements. Aviat Space Environ Med 1977; 48(3): 203-209. (Pubitemid 8072442)
    • (1977) Aviation Space and Environmental Medicine , vol.48 , Issue.3 , pp. 203-209
    • Triebwasser, J.H.1    Johnson Jr., R.L.2    Burpo, R.P.3
  • 18
    • 18244361864 scopus 로고    scopus 로고
    • Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
    • DOI 10.1042/CS20010158
    • Gabrielsen A, Videbaek R, Schou M, Damgaard M, Kastrup J, Norsk P. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci 2002; 102(2): 247-252. (Pubitemid 34185053)
    • (2002) Clinical Science , vol.102 , Issue.2 , pp. 247-252
    • Gabrielsen, A.1    VidebaeK, R.2    Schou, M.3    Damgaard, M.4    Kastrup, J.5    Norsk, P.6
  • 19
    • 20944450900 scopus 로고    scopus 로고
    • Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen fick method in measurement of pulmonary blood flow
    • DOI 10.1007/s10877-005-1589-6
    • Peyton PJ, Thompson B. Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen Fick method in measurement of pulmonary blood flow. J Clin Monit Comput 2005; 18(5-6): 373-378. (Pubitemid 40867423)
    • (2004) Journal of Clinical Monitoring and Computing , vol.18 , Issue.5-6 , pp. 373-378
    • Peyton, P.J.1    Thompson, B.2
  • 20
    • 68349125545 scopus 로고    scopus 로고
    • Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique
    • Peyton PJ, Bailey M, Thompson BR. Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique. J Clin Monit Comput 2009; 23(4): 233-236.
    • (2009) J Clin Monit Comput , vol.23 , Issue.4 , pp. 233-236
    • Peyton, P.J.1    Bailey, M.2    Thompson, B.R.3
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, DG Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15(2): 85-91. (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 23
    • 78049343101 scopus 로고    scopus 로고
    • Minimally invasive measurement of cardiac output during surgery and critical care: A meta-analysis of accuracy and precision
    • Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 2010; 113(5): 1220-1235.
    • (2010) Anesthesiology , vol.113 , Issue.5 , pp. 1220-1235
    • Peyton, P.J.1    Chong, S.W.2
  • 25
    • 68349110713 scopus 로고    scopus 로고
    • Noninvasive determination of cardiac output by the inert-gas-rebreathing method-comparison with cardiovascular magnetic resonance imaging
    • Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ. Noninvasive determination of cardiac output by the inert-gas-rebreathing method-comparison with cardiovascular magnetic resonance imaging. Cardiology 2009; 114(4): 247-254.
    • (2009) Cardiology , vol.114 , Issue.4 , pp. 247-254
    • Saur, J.1    Fluechter, S.2    Trinkmann, F.3    Papavassiliu, T.4    Schoenberg, S.5    Weissmann, J.6    Haghi, D.7    Borggrefe, M.8    Kaden, J.J.9
  • 27
  • 28
    • 0034869820 scopus 로고    scopus 로고
    • A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    • DOI 10.1093/bja/87.2.212
    • Jansen JR, Schreuder JJ, Mulier JP, Smith NT, Settels JJ, Wesseling KH. A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 2001; 87(2): 212-222. (Pubitemid 32750529)
    • (2001) British Journal of Anaesthesia , vol.87 , Issue.2 , pp. 212-222
    • Jansen, J.R.C.1    Schreuder, J.J.2    Mulier, J.P.3    Smith, N.T.4    Settels, J.J.5    Wesseling, K.H.6
  • 30
    • 0036385496 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    • Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Chest 2002; 122(3): 990-997.
    • (2002) Chest , vol.122 , Issue.3 , pp. 990-997
    • Dhingra, V.K.1    Fenwick, J.C.2    Walley, K.R.3    Chittock, D.R.4    Ronco, J.J.5