메뉴 건너뛰기




Volumn 27, Issue 6, 2013, Pages 1108-1113

Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery

Author keywords

anesthesia; atrial fibrillation; cardiac index; cardiac surgery; high risk patients; intensive care; PRAM; pressure recording analytic method; pulmonary artery catheter; thermodilution; unstable patients

Indexed keywords

INOTROPIC AGENT;

EID: 84888299071     PISSN: 10530770     EISSN: 15328422     Source Type: Journal    
DOI: 10.1053/j.jvca.2013.02.016     Document Type: Article
Times cited : (22)

References (26)
  • 2
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • J.D. Sandham, R.D. Hull, and R.F. Brunt A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients N Engl J Med 348 2003 5 14
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brunt, R.F.3
  • 3
    • 0344234439 scopus 로고    scopus 로고
    • Perioperative management and monitoring in anaesthesia
    • W. Buhre, and R. Rossaint Perioperative management and monitoring in anaesthesia Lancet 362 2003 1839 1846
    • (2003) Lancet , vol.362 , pp. 1839-1846
    • Buhre, W.1    Rossaint, R.2
  • 5
    • 34249089562 scopus 로고    scopus 로고
    • What technique should i use to measure cardiac output?
    • C.K. Hofer, M.T. Ganter, and A. Zollinger What technique should I use to measure cardiac output? Curr Opin Crit Care 13 2007 308 317
    • (2007) Curr Opin Crit Care , vol.13 , pp. 308-317
    • Hofer, C.K.1    Ganter, M.T.2    Zollinger, A.3
  • 7
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • S.M. Romano, and M. Pistolesi Assessment of cardiac output from systemic arterial pressure in humans Crit Care Med 30 2002 1834 1841
    • (2002) Crit Care Med , vol.30 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 8
    • 77950020487 scopus 로고    scopus 로고
    • Cardiac index validation using the pressure recording analytic method in unstable patients
    • A. Zangrillo, G. Maj, and F. Monaco Cardiac index validation using the pressure recording analytic method in unstable patients J Cardiothorac Vasc Anesth 24 2010 265 269
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 265-269
    • Zangrillo, A.1    Maj, G.2    Monaco, F.3
  • 9
    • 79957734925 scopus 로고    scopus 로고
    • Cardiac index assessment by the pressure recording analytic method in unstable patients with atrial fibrillation
    • G. Maj, F. Monaco, and G. Landoni Cardiac index assessment by the pressure recording analytic method in unstable patients with atrial fibrillation J Cardiothorac Vasc Anesth 25 2011 476 480
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 476-480
    • Maj, G.1    Monaco, F.2    Landoni, G.3
  • 10
    • 82255192417 scopus 로고    scopus 로고
    • An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation
    • S. Scolletta, F. Franchi, and F.S. Taccone An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation Anesth Analg 113 2011 1389 1395
    • (2011) Anesth Analg , vol.113 , pp. 1389-1395
    • Scolletta, S.1    Franchi, F.2    Taccone, F.S.3
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J.M. Bland, and D.G. Altman Measuring agreement in method comparison studies Stat Methods Med Res 8 1999 135 160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • L.A. Critchley, and J.A. Critchley A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 1999 85 91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 13
    • 79958110885 scopus 로고    scopus 로고
    • Systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • M.A. Hamilton, M. Cecconi, and A. Rhodes Systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients Anesth Analg 112 2011 1392 1402
    • (2011) Anesth Analg , vol.112 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 14
    • 70449475939 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform
    • J. Mayer, and S. Suttner Cardiac output derived from arterial pressure waveform Curr Opin Anaesthesiol 22 2009 804 808
    • (2009) Curr Opin Anaesthesiol , vol.22 , pp. 804-808
    • Mayer, J.1    Suttner, S.2
  • 15
    • 4143134234 scopus 로고    scopus 로고
    • Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    • P. Giomarelli, B. Biagioli, and S. Scolletta Cardiac output monitoring by pressure recording analytical method in cardiac surgery Eur J Cardiothorac Surg 26 2004 515 520
    • (2004) Eur J Cardiothorac Surg , vol.26 , pp. 515-520
    • Giomarelli, P.1    Biagioli, B.2    Scolletta, S.3
  • 16
    • 23844520689 scopus 로고    scopus 로고
    • Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states
    • S. Scolletta, S.M. Romano, and B. Biagioli Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states Br J Anaesth 95 2005 159 165
    • (2005) Br J Anaesth , vol.95 , pp. 159-165
    • Scolletta, S.1    Romano, S.M.2    Biagioli, B.3
  • 17
    • 34347398471 scopus 로고    scopus 로고
    • Pulse wave analysis to assess systemic blood flow during mechanical biventricular support
    • S. Scolletta, I.D. Gregoric, and L. Muzzi Pulse wave analysis to assess systemic blood flow during mechanical biventricular support Perfusion 22 2007 63 66
    • (2007) Perfusion , vol.22 , pp. 63-66
    • Scolletta, S.1    Gregoric, I.D.2    Muzzi, L.3
  • 18
    • 33645779232 scopus 로고    scopus 로고
    • Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation
    • S.M. Romano, S. Scolletta, and I. Olivotto Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation Perfusion 21 2006 109 116
    • (2006) Perfusion , vol.21 , pp. 109-116
    • Romano, S.M.1    Scolletta, S.2    Olivotto, I.3
  • 19
    • 48749118713 scopus 로고    scopus 로고
    • Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method
    • T. Balderi, F. Forfori, and V. Marra Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method Obes Surg 18 2008 1007 1014
    • (2008) Obes Surg , vol.18 , pp. 1007-1014
    • Balderi, T.1    Forfori, F.2    Marra, V.3
  • 20
    • 48749109474 scopus 로고    scopus 로고
    • Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient
    • D.P. Bernstein Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient Obes Surg 18 2008 1015 1021
    • (2008) Obes Surg , vol.18 , pp. 1015-1021
    • Bernstein, D.P.1
  • 21
    • 43549100903 scopus 로고    scopus 로고
    • Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiography
    • M. Calamandrei, L. Mirabile, and S. Muschetta Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiography Pediatr Crit Care Med 9 2008 310 312
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 310-312
    • Calamandrei, M.1    Mirabile, L.2    Muschetta, S.3
  • 22
    • 79959664305 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device
    • S. Scolletta, F. Miraldi, and S.M. Romano Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device Interact Cardiovasc Thorac Surg 13 2011 52 56
    • (2011) Interact Cardiovasc Thorac Surg , vol.13 , pp. 52-56
    • Scolletta, S.1    Miraldi, F.2    Romano, S.M.3
  • 23
    • 70449503614 scopus 로고    scopus 로고
    • Cardiac efficiency improvement after slow continuous ultrafiltration is assessed by beat-to-beat minimally invasive monitoring in congestive heart failure patients: A preliminary report
    • C. Giglioli, D. Landi, and G.F. Gensini Cardiac efficiency improvement after slow continuous ultrafiltration is assessed by beat-to-beat minimally invasive monitoring in congestive heart failure patients: A preliminary report Blood Purif 29 2010 44 51
    • (2010) Blood Purif , vol.29 , pp. 44-51
    • Giglioli, C.1    Landi, D.2    Gensini, G.F.3
  • 24
    • 79952935360 scopus 로고    scopus 로고
    • Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients
    • H. Paarmann, H.V. Groesdonk, and B. Sedemund-Adib Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients Br J Anaesth 106 2011 475 481
    • (2011) Br J Anaesth , vol.106 , pp. 475-481
    • Paarmann, H.1    Groesdonk, H.V.2    Sedemund-Adib, B.3
  • 25
    • 15944386360 scopus 로고    scopus 로고
    • Precision of bolus thermodilution cardiac output measurements in patients with atrial fibrillation
    • M. Ostergaard, L.B. Nilsson, and J.C. Nilsson Precision of bolus thermodilution cardiac output measurements in patients with atrial fibrillation Acta Anaesthesiol Scand 49 2005 366 372
    • (2005) Acta Anaesthesiol Scand , vol.49 , pp. 366-372
    • Ostergaard, M.1    Nilsson, L.B.2    Nilsson, J.C.3
  • 26
    • 77950019418 scopus 로고    scopus 로고
    • Validity of an arterial pressure waveform analysis device: Does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?
    • S. Schramm, E. Albrecht, and P. Frascarolo Validity of an arterial pressure waveform analysis device: Does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements? J Cardiothorac Vasc Anesth 24 2010 250 256
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 250-256
    • Schramm, S.1    Albrecht, E.2    Frascarolo, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.