메뉴 건너뛰기




Volumn 17, Issue 3, 2011, Pages 296-302

Pulmonary artery catheter monitoring in 2011

Author keywords

cardiac output; pulmonary artery catheter; pulmonary hypertension; right ventricular failure; weaning from mechanical ventilation

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; CRITICALLY ILL PATIENT; HEART FAILURE; HEART OUTPUT; HEART RIGHT VENTRICLE FAILURE; HEMODYNAMIC MONITORING; HUMAN; LUNG ARTERY PRESSURE; OXYGENATION; PUBLISHING; PULMONARY ARTERY CATHETER; PULMONARY ARTERY OCCLUSION; PULMONARY HYPERTENSION; SHOCK; VALIDATION PROCESS;

EID: 79955631501     PISSN: 10705295     EISSN: 15317072     Source Type: Journal    
DOI: 10.1097/MCC.0b013e3283466b85     Document Type: Article
Times cited : (51)

References (46)
  • 2
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • DOI 10.1016/S0140-6736(05)67061-4, PII S0140673605670614
    • Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005; 366:472-477. (Pubitemid 41111695)
    • (2005) Lancet , vol.366 , Issue.9484 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3    Ashcroft, J.4    Jones, C.M.5    Elbourne, D.6    Brampton, W.7    Williams, D.8    Young, D.9    Rowan, K.10
  • 4
    • 77958004569 scopus 로고    scopus 로고
    • Medical and surgical treatment of acute right ventricular failure
    • Lahm T, McCaslin CA, Wozniak TC, et al. Medical and surgical treatment of acute right ventricular failure. J Am Coll Cardiol 2010; 56:1435-1446.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1435-1446
    • Lahm, T.1    McCaslin, C.A.2    Wozniak, T.C.3
  • 5
    • 78149278970 scopus 로고    scopus 로고
    • Clinical review: Practical recommen-dations on the management of perioperative heart failure in cardiac surgery
    • Mebazaa A, Pitsis AA, Rudiger A, et al. Clinical review: practical recommen-dations on the management of perioperative heart failure in cardiac surgery. Crit Care 2010; 14:201.
    • (2010) Crit Care , vol.14 , pp. 201
    • Mebazaa, A.1    Pitsis, A.A.2    Rudiger, A.3
  • 6
    • 79955582037 scopus 로고    scopus 로고
    • Pulmonary artery catheter: Balance between safe and optimal use
    • Chiche JD, Moreno R, Putensen C, Rhodes A editors; Berlin: Medizinish Wissenschaftliche Verlagsgesellschaft
    • Teboul JL, Monnet X, Richard C. Pulmonary artery catheter: balance between safe and optimal use; in Patient Safety and Quality of Care in Intensive care Medicine: Chiche JD, Moreno R, Putensen C, Rhodes A editors; Berlin: Medizinish Wissenschaftliche Verlagsgesellschaft; 2009 pp 475-484.
    • (2009) Patient Safety and Quality of Care in Intensive Care Medicine , pp. 475-484
    • Teboul, J.L.1    Monnet, X.2    Richard, C.3
  • 7
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: Basics, limits, and perspectives
    • Reuter DA, Huang C, Edrich T, et al. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg 2010; 110:799-811.
    • (2010) Anesth Analg , vol.110 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3
  • 9
    • 77956197011 scopus 로고    scopus 로고
    • Right ventricular function evaluation in acute respiratory distress syndrome: Back to the future
    • Vieillard-Baron A, Bouferrache K, Charron C. Right ventricular function evaluation in acute respiratory distress syndrome: back to the future. Crit Care Med 2010; 38:1909-1910.
    • (2010) Crit Care Med , vol.38 , pp. 1909-1910
    • Vieillard-Baron, A.1    Bouferrache, K.2    Charron, C.3
  • 10
    • 4644290657 scopus 로고    scopus 로고
    • Treatment of pulmonary arterial hypertension
    • Humbert M, Sitbon O, Simonneau G. Treatment of pulmonary arterial hypertension. N Engl J Med 2004; 351:1425-1436.
    • (2004) N Engl J Med , vol.351 , pp. 1425-1436
    • Humbert, M.1    Sitbon, O.2    Simonneau, G.3
  • 11
    • 65249161113 scopus 로고    scopus 로고
    • Accuracy of doppler echocardio-graphy in the hemodynamic assessment of pulmonary hypertension
    • Fisher MR, Forfia PR, Chamera E, et al. Accuracy of Doppler echocardio-graphy in the hemodynamic assessment of pulmonary hypertension. Am J Respir Crit Care Med 2009; 179:615-621.
    • (2009) Am J Respir Crit Care Med , vol.179 , pp. 615-621
    • Fisher, M.R.1    Forfia, P.R.2    Chamera, E.3
  • 12
    • 58549083739 scopus 로고    scopus 로고
    • Incidence and prognostic value of right ventricular failure in acute respiratory distress syndrome
    • Osman D, Monnet X, Castelain V, et al. Incidence and prognostic value of right ventricular failure in acute respiratory distress syndrome. Intensive Care Med 2009; 35:69-76.
    • (2009) Intensive Care Med , vol.35 , pp. 69-76
    • Osman, D.1    Monnet, X.2    Castelain, V.3
  • 13
    • 77649203752 scopus 로고    scopus 로고
    • Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: Systematic review and meta-analysis
    • Briel M, Meade M, Mercat A, et al. Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: systematic review and meta-analysis. JAMA 2010; 303:865-873.
    • (2010) JAMA , vol.303 , pp. 865-873
    • Briel, M.1    Meade, M.2    Mercat, A.3
  • 15
    • 77249093975 scopus 로고    scopus 로고
    • Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: Importance of the volume status
    • Fougeres E, Teboul JL, Richard C, et al. Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: importance of the volume status. Crit Care Med 2010; 38:802-807.
    • (2010) Crit Care Med , vol.38 , pp. 802-807
    • Fougeres, E.1    Teboul, J.L.2    Richard, C.3
  • 16
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15:85-91. (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 17
    • 79955575487 scopus 로고    scopus 로고
    • The inaccuracy of doppler echocardiographic estimates of PAPs in patients with pulmonary hypertension: Implications for clinical practice
    • [Epub ahead of print]
    • Rich JD, Shah SJ, Swamy R, et al. The inaccuracy of Doppler echocardiographic estimates of PAPs in patients with pulmonary hypertension: implications for clinical practice. Chest 2010. [Epub ahead of print]
    • (2010) Chest
    • Rich, J.D.1    Shah, S.J.2    Swamy, R.3
  • 18
    • 78649335297 scopus 로고    scopus 로고
    • Can echocardiographic evaluation of cardiopulmonary hemodynamics decrease right heart catheterizations in end-stage heart failure patients awaiting transplantation?
    • Kuppahally SS, Michaels AD, Tandar A, et al. Can echocardiographic evaluation of cardiopulmonary hemodynamics decrease right heart catheterizations in end-stage heart failure patients awaiting transplantation? Am J Cardiol 2010; 106:1657-1662.
    • (2010) Am J Cardiol , vol.106 , pp. 1657-1662
    • Kuppahally, S.S.1    Michaels, A.D.2    Tandar, A.3
  • 19
    • 14644415523 scopus 로고    scopus 로고
    • Increased pulmonary venous resistance contributes to increased pulmonary artery diastolic-pulmonary wedge pressure gradient in acute respiratory distress syndrome
    • DOI 10.1097/00000542-200503000-00016
    • Her C, Mandy S, Bairamian M. Increased pulmonary venous resistance contributes to increased pulmonary artery diastolic-pulmonary wedge pressure gradient in acute respiratory distress syndrome. Anesthesiology 2005; 102:574-580. (Pubitemid 40315148)
    • (2005) Anesthesiology , vol.102 , Issue.3 , pp. 574-580
    • Her, C.1    Mandy, S.2    Bairamian, M.3
  • 20
    • 0026520979 scopus 로고
    • Bedside evaluation of the resistance of large and medium pulmonary veins in various lung diseases
    • Teboul JL, Andrivet P, Ansquer M, et al. Bedside evaluation of the resistance of large and medium pulmonary veins in various lung diseases. J Appl Physiol 1992; 72:998-1003.
    • (1992) J Appl Physiol , vol.72 , pp. 998-1003
    • Teboul, J.L.1    Andrivet, P.2    Ansquer, M.3
  • 22
    • 77957008940 scopus 로고    scopus 로고
    • Increased pulmonary venous resistance in morbidly obese patients without daytime hypoxia: Clinical utility of the pulmonary artery catheter
    • Her C, Cerabona T, Baek SH, Shin SW. Increased pulmonary venous resistance in morbidly obese patients without daytime hypoxia: clinical utility of the pulmonary artery catheter. Anesthesiology 2010; 113:552-559.
    • (2010) Anesthesiology , vol.113 , pp. 552-559
    • Her, C.1    Cerabona, T.2    Baek, S.H.3    Shin, S.W.4
  • 23
    • 78149270921 scopus 로고    scopus 로고
    • Weaning failure of cardiac origin: Recent advances
    • Teboul JL, Monnet X, Richard C. Weaning failure of cardiac origin: recent advances. Crit Care 2010; 14:211.
    • (2010) Crit Care , vol.14 , pp. 211
    • Teboul, J.L.1    Monnet, X.2    Richard, C.3
  • 24
    • 77954387228 scopus 로고    scopus 로고
    • Physiological comparison of three spontaneous breathing trials in difficult-to-wean patients
    • Cabello B, Thille AW, Roche-Campo F, et al. Physiological comparison of three spontaneous breathing trials in difficult-to-wean patients. Intensive Care Med 2010; 36:1171-1179.
    • (2010) Intensive Care Med , vol.36 , pp. 1171-1179
    • Cabello, B.1    Thille, A.W.2    Roche-Campo, F.3
  • 25
    • 78650585959 scopus 로고    scopus 로고
    • Nitroglycerin can facilitate weaning of difficult-to-wean COPD patients: A prospective interventional nonrandomized study
    • Routsi C, Stanopoulos I, Zakynthinos E, et al. Nitroglycerin can facilitate weaning of difficult-to-wean COPD patients: a prospective interventional nonrandomized study. Crit Care 2010; 14:R204.
    • (2010) Crit Care , vol.14
    • Routsi, C.1    Stanopoulos, I.2    Zakynthinos, E.3
  • 27
    • 67650483327 scopus 로고    scopus 로고
    • Echocardiographic diagnosis of pulmonary artery occlusion pressure elevation during weaning from mechanical ventilation
    • Lamia B, Maizel J, Ochagavia A, et al. Echocardiographic diagnosis of pulmonary artery occlusion pressure elevation during weaning from mechanical ventilation. Crit Care Med 2009; 37:1696-1701.
    • (2009) Crit Care Med , vol.37 , pp. 1696-1701
    • Lamia, B.1    Maizel, J.2    Ochagavia, A.3
  • 28
    • 46149095773 scopus 로고    scopus 로고
    • Increase in plasma protein concentration for diagnosing weaning-induced pulmonary oedema
    • DOI 10.1007/s00134-008-1038-3
    • Anguel N, Monnet X, Osman D, et al. Increase in plasma protein concentration for diagnosing weaning-induced pulmonary oedema. Intensive Care Med 2008; 34:1231-1238. (Pubitemid 351904293)
    • (2008) Intensive Care Medicine , vol.34 , Issue.7 , pp. 1231-1238
    • Anguel, N.1    Monnet, X.2    Osman, D.3    Castelain, V.4    Richard, C.5    Teboul, J.-L.6
  • 29
    • 27944490692 scopus 로고    scopus 로고
    • Weaning failure from cardiovascular origin
    • DOI 10.1007/s00134-005-2698-x
    • Richard C, Teboul JL. Weaning failure from cardiovascular origin. Intensive Care Med 2005; 31:1605-1607. (Pubitemid 41677233)
    • (2005) Intensive Care Medicine , vol.31 , Issue.12 , pp. 1605-1607
    • Richard, C.1    Teboul, J.L.2
  • 30
    • 0032434106 scopus 로고    scopus 로고
    • Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof
    • Jubran A, Mathru M, Dries D, Tobin MJ. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof. Am J Respir Crit Care Med 1998; 158:1763-1769. (Pubitemid 29008812)
    • (1998) American Journal of Respiratory and Critical Care Medicine , vol.158 , Issue.6 , pp. 1763-1769
    • Jubran, A.1    Mathru, M.2    Dries, D.3    Tobin, M.J.4
  • 31
    • 0027427633 scopus 로고
    • A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients
    • DOI 10.1001/jama.270.22.2699
    • Boyd O, Grounds RM, Bennett ED. A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 1993; 270:2699-2707. (Pubitemid 23350967)
    • (1993) Journal of the American Medical Association , vol.270 , Issue.22 , pp. 2699-2707
    • Boyd, O.1    Grounds, R.M.2    Bennett, E.D.3
  • 32
    • 0036342470 scopus 로고    scopus 로고
    • Meta-analysis of hemodynamic optimization in high-risk patients
    • Kern JW, Shoemaker WC. Meta-analysis of hemodynamic optimization in high-risk patients. Crit Care Med 2002; 30:1686-1692. (Pubitemid 34879575)
    • (2002) Critical Care Medicine , vol.30 , Issue.8 , pp. 1686-1692
    • Kern, J.W.1    Shoemaker, W.C.2
  • 33
    • 77956022598 scopus 로고    scopus 로고
    • Prognostic studies of perioperative risk: Robust methodology is needed
    • Grocott MP, Pearse RM. Prognostic studies of perioperative risk: robust methodology is needed. Br J Anaesth 2010; 105:243-245.
    • (2010) Br J Anaesth , vol.105 , pp. 243-245
    • Grocott, M.P.1    Pearse, R.M.2
  • 34
    • 79958103972 scopus 로고    scopus 로고
    • A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • [Epub ahead of print]
    • Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg 2010. [Epub ahead of print]
    • (2010) Anesth Analg
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 35
    • 0032734448 scopus 로고    scopus 로고
    • Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    • Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al. Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. Crit Care Med 1999; 27:2407-2412.
    • (1999) Crit Care Med , vol.27 , pp. 2407-2412
    • Goedje, O.1    Hoeke, K.2    Lichtwarck-Aschoff, M.3
  • 36
    • 0032847442 scopus 로고    scopus 로고
    • Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    • DOI 10.1007/s001340050962
    • Sakka SG, Reinhart K, Meier-Hellmann A. Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients. Intensive Care Med 1999; 25:843-846. (Pubitemid 29410653)
    • (1999) Intensive Care Medicine , vol.25 , Issue.8 , pp. 843-846
    • Sakka, S.G.1    Reinhart, K.2    Meier-Hellmann, A.3
  • 37
    • 59649127189 scopus 로고    scopus 로고
    • Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: Validation of a novel method
    • Friesecke S, Heinrich A, Abel P, Felix SB. Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: validation of a novel method. Crit Care Med 2009; 37:119-123.
    • (2009) Crit Care Med , vol.37 , pp. 119-123
    • Friesecke, S.1    Heinrich, A.2    Abel, P.3    Felix, S.B.4
  • 38
    • 0037865718 scopus 로고    scopus 로고
    • Cardiovascular monitoring tools: Use and misuse
    • DOI 10.1097/00075198-200306000-00010
    • Bellomo R, Uchino S. Cardiovascular monitoring tools: use and misuse. Curr Opin Crit Care 2003; 9:225-229. (Pubitemid 36667820)
    • (2003) Current Opinion in Critical Care , vol.9 , Issue.3 , pp. 225-229
    • Bellomo, R.1    Uchino, S.2
  • 39
    • 38549151697 scopus 로고    scopus 로고
    • Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
    • DOI 10.1097/01.CCM.OB013E318161FEC4, PII 0000324620080200000010
    • Hamzaoui O, Monnet X, Richard C, et al. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-h calibration-free period. Crit Care Med 2008; 36:434-440. (Pubitemid 351158616)
    • (2008) Critical Care Medicine , vol.36 , Issue.2 , pp. 434-440
    • Hamzaoui, O.1    Monnet, X.2    Richard, C.3    Osman, D.4    Chemla, D.5    Teboul, J.-L.6
  • 40
    • 72449201516 scopus 로고    scopus 로고
    • Tracking changes in cardiac output: Methodological considerations for the validation of monitoring devices
    • Squara P, Cecconi M, Rhodes A, et al. Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices. Intensive Care Med 2009; 35:1801-1808.
    • (2009) Intensive Care Med , vol.35 , pp. 1801-1808
    • Squara, P.1    Cecconi, M.2    Rhodes, A.3
  • 41
    • 78149469431 scopus 로고    scopus 로고
    • A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
    • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010; 111:1180-1192.
    • (2010) Anesth Analg , vol.111 , pp. 1180-1192
    • Critchley, L.A.1    Lee, A.2    Ho, A.M.3
  • 42
    • 57349199888 scopus 로고    scopus 로고
    • Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
    • Biancofiore G, Critchley LA, Lee A, et al. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth 2009; 102:47-54.
    • (2009) Br J Anaesth , vol.102 , pp. 47-54
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3
  • 45
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients
    • De Backer D, Marx G, Tan A, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med 2011; 37:233-240.
    • (2011) Intensive Care Med , vol.37 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3
  • 46
    • 78049343101 scopus 로고    scopus 로고
    • Minimally invasive measurement of cardiac output during surgery and critical care: A meta-analysis of accuracy and precision
    • Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 2010; 113:1220-1235.
    • (2010) Anesthesiology , vol.113 , pp. 1220-1235
    • Peyton, P.J.1    Chong, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.