메뉴 건너뛰기




Volumn 13, Issue 4, 1999, Pages 437-440

Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting

Author keywords

Cardiac surgery; Continuous cardiac output; Pulse contour analysis

Indexed keywords

SODIUM CHLORIDE;

EID: 0032817727     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(99)90216-1     Document Type: Article
Times cited : (133)

References (18)
  • 1
    • 0026650088 scopus 로고
    • Continuous cardiac output measurements in critically ill patients
    • Iberti TJ, Silverstein JH: Continuous cardiac output measurements in critically ill patients. J Cardiothorac Vasc Anesth 6:267, 1992
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 267
    • Iberti, T.J.1    Silverstein, J.H.2
  • 2
    • 0028605517 scopus 로고
    • Comparison of cardiac output measurement by continuous thermodilution with electromagnetrometry in adult cardiac surgical patients
    • Hogue CW Jr, Rosenbloom M, McCawley C, Lappas DG: Comparison of cardiac output measurement by continuous thermodilution with electromagnetrometry in adult cardiac surgical patients. J Cardiothorac Vasc Anesth 8:631-635, 1994
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 631-635
    • Hogue Jr., C.W.1    Rosenbloom, M.2    McCawley, C.3    Lappas, D.G.4
  • 3
    • 0025306085 scopus 로고
    • Continuous measurement of cardiac output based on the Pick principle in cardiac anesthesia
    • Rieke H, Weyland A, Hoeft A, et al: Continuous measurement of cardiac output based on the Pick principle in cardiac anesthesia. Anaesthesist 39:13-21, 1990
    • (1990) Anaesthesist , vol.39 , pp. 13-21
    • Rieke, H.1    Weyland, A.2    Hoeft, A.3
  • 4
    • 0029893410 scopus 로고    scopus 로고
    • Minimally invasive direct coronary artery bypass (MIDCAB): Surgical techniques and anesthetic considerations
    • Greenspun HG, Adourian UA, Fonger JD, Fan JS: Minimally invasive direct coronary artery bypass (MIDCAB): Surgical techniques and anesthetic considerations. J Cardiothorac Vasc Anesth 10:507-509, 1996
    • (1996) J Cardiothorac Vasc Anesth , vol.10 , pp. 507-509
    • Greenspun, H.G.1    Adourian, U.A.2    Fonger, J.D.3    Fan, J.S.4
  • 5
    • 0029937462 scopus 로고    scopus 로고
    • Anesthetic considerations for patients undergoing minimally invasive coronary artery bypass surgery: Ministernotomy and minithoracotomy approaches
    • Gayes JM, Emery RW, Nissen MD: Anesthetic considerations for patients undergoing minimally invasive coronary artery bypass surgery: Ministernotomy and minithoracotomy approaches. J Cardiothorac Vasc Anesth 10:531-535, 1996
    • (1996) J Cardiothorac Vasc Anesth , vol.10 , pp. 531-535
    • Gayes, J.M.1    Emery, R.W.2    Nissen, M.D.3
  • 6
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • Yelderman ML: Continuous measurement of cardiac output with the use of stochastic system identification techniques. J Clin Monit 6:322-332, 1990
    • (1990) J Clin Monit , vol.6 , pp. 322-332
    • Yelderman, M.L.1
  • 7
    • 0026695419 scopus 로고
    • Continuous thermodilution cardiac output measurements in intensive care unit patients
    • Yelderman ML, Ramsay MA, Quinn MD, et al: Continuous thermodilution cardiac output measurements in intensive care unit patients. J Cardiothorac Vasc Anesth 6:270-274, 1992
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 270-274
    • Yelderman, M.L.1    Ramsay, M.A.2    Quinn, M.D.3
  • 9
    • 0027525172 scopus 로고
    • Arterial pulse contour analysis trending of cardiac output: Hemodynamic manipulations during cerebral arteriovenous malformation resection
    • Weissman C, Ornstein E, Young WL: Arterial pulse contour analysis trending of cardiac output: Hemodynamic manipulations during cerebral arteriovenous malformation resection. J Clin Monit 9:347-353, 1993
    • (1993) J Clin Monit , vol.9 , pp. 347-353
    • Weissman, C.1    Ornstein, E.2    Young, W.L.3
  • 10
    • 0027143983 scopus 로고
    • Pulse contour cardiac output in surgical intensive care unit patients
    • Tannenbaum GA, Mathews D, Weissman C: Pulse contour cardiac output in surgical intensive care unit patients. J Clin Anesth 5:471-478, 1993
    • (1993) J Clin Anesth , vol.5 , pp. 471-478
    • Tannenbaum, G.A.1    Mathews, D.2    Weissman, C.3
  • 11
    • 0029090208 scopus 로고
    • Continuous measurement of cardiac output with pulse contour analysis
    • Irlbeck M, Forst H, Briegel J, et al: Continuous measurement of cardiac output with pulse contour analysis. Anaesthesist 44:493-500, 1995
    • (1995) Anaesthesist , vol.44 , pp. 493-500
    • Irlbeck, M.1    Forst, H.2    Briegel, J.3
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0025166460 scopus 로고
    • Non-invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation
    • Spahn DR, Schmid ER, Tornic M, et al: Non-invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation. J Cardiothorac Vasc Anesth 4:46-59, 1990
    • (1990) J Cardiothorac Vasc Anesth , vol.4 , pp. 46-59
    • Spahn, D.R.1    Schmid, E.R.2    Tornic, M.3
  • 15
    • 0025221173 scopus 로고
    • An adequate strategy for the thermodilution technique in patients during mechanical ventilation
    • Jansen JR, Schreuder JJ, Settels JJ, et al: An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med 16:422-425, 1990
    • (1990) Intensive Care Med , vol.16 , pp. 422-425
    • Jansen, J.R.1    Schreuder, J.J.2    Settels, J.J.3
  • 16
    • 0025914221 scopus 로고
    • Continuous determination of cardiac output using a flow-directed Doppler pulmonary artery catheter
    • Segal J, Gaudiani V, Nishimura T: Continuous determination of cardiac output using a flow-directed Doppler pulmonary artery catheter. J Cardiothorac Vasc Anesth 5:309-315, 1991
    • (1991) J Cardiothorac Vasc Anesth , vol.5 , pp. 309-315
    • Segal, J.1    Gaudiani, V.2    Nishimura, T.3
  • 17
    • 0029826711 scopus 로고    scopus 로고
    • Cardiac output determination with transpulmonary thermodilution. An alternative to pulmonary catheterization?
    • von Spiegel T, Wietasch G, Bürsch J, Hoeft A: Cardiac output determination with transpulmonary thermodilution. An alternative to pulmonary catheterization? Anaesthesist 45:1045-1050, 1996
    • (1996) Anaesthesist , vol.45 , pp. 1045-1050
    • Von Spiegel, T.1    Wietasch, G.2    Bürsch, J.3    Hoeft, A.4
  • 18
    • 0001789280 scopus 로고
    • Transpulmonary indicator dilution: An alternative approach for hemodynamic monitoring
    • Vincent JL (ed): Berlin, Germany, Springer
    • Hoeft A: Transpulmonary indicator dilution: An alternative approach for hemodynamic monitoring, in Vincent JL (ed): Yearbook of Intensive Care and Emergency Medicine. Berlin, Germany, Springer, 1995, pp 593-605
    • (1995) Yearbook of Intensive Care and Emergency Medicine , pp. 593-605
    • Hoeft, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.