메뉴 건너뛰기




Volumn 16, Issue 6, 2010, Pages 773-782

Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ALGORITHM; ARTERIAL PRESSURE; ARTICLE; CALIBRATION; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; CORRELATION ANALYSIS; FEMALE; HEART INDEX; HEART OUTPUT; HUMAN; INTERMETHOD COMPARISON; LIVER TRANSPLANTATION; MALE; MEASUREMENT; MONITOR; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY; SYSTEMIC VASCULAR RESISTANCE; THERMODILUTION; VALIDATION STUDY;

EID: 77953638305     PISSN: 15276465     EISSN: 15276473     Source Type: Journal    
DOI: 10.1002/lt.22056     Document Type: Article
Times cited : (58)

References (32)
  • 1
    • 33144458362 scopus 로고    scopus 로고
    • Arterial hypertension in cirrhosis: Arterial compliance, volume distribution, and central haemodynamics
    • Henriksen JH, Fuglsang S, Bendtsen F, Moller S. Arterial hypertension in cirrhosis: arterial compliance, volume distribution, and central haemodynamics. Gut 2006;55: 380-387.
    • (2006) Gut , vol.55 , pp. 380-387
    • Henriksen, J.H.1    Fuglsang, S.2    Bendtsen, F.3    Moller, S.4
  • 2
    • 33644892769 scopus 로고    scopus 로고
    • Cardiopulmonary complications in chronic liver disease
    • Moller S, Henriksen JH. Cardiopulmonary complications in chronic liver disease. World J Gastroenterol 2006;12: 526-538. (Pubitemid 43380781)
    • (2006) World Journal of Gastroenterology , vol.12 , Issue.4 , pp. 526-538
    • Moller, S.1    Henriksen, J.H.2
  • 3
    • 0027252852 scopus 로고
    • Hemodynamic monitoring during orthotopic liver transplantation
    • De Wolf A. Hemodynamic monitoring during orthotopic liver transplantation. Transplant Proc 1993;25: 1863-1864. (Pubitemid 23125121)
    • (1993) Transplantation Proceedings , vol.25 , Issue.2 , pp. 1863-1864
    • De Wolf, A.1
  • 4
    • 33749587013 scopus 로고    scopus 로고
    • Perioperative assessment of the cardiovascular system in ESLD and transplantation
    • De Wolf AM. Perioperative assessment of the cardiovascular system in ESLD and transplantation. Int Anesthesiol Clin 2006;44:59-78.
    • (2006) Int Anesthesiol Clin , vol.44 , pp. 59-78
    • De Wolf, A.M.1
  • 5
    • 48949120285 scopus 로고    scopus 로고
    • Pulmonary artery catheter: Rest in peace? Not just quite yet
    • De Wolf AM. Pulmonary artery catheter: rest in peace? Not just quite yet. Liver Transpl 2008;14:917-918.
    • (2008) Liver Transpl , vol.14 , pp. 917-918
    • De Wolf, A.M.1
  • 6
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003;348:5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3    Knox, L.4    Pineo, G.F.5    Doig, C.J.6
  • 8
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients
    • Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA 1996;276:889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors Jr., A.F.1    Speroff, T.2    Dawson, N.V.3    Thomas, C.4    Harrell Jr., F.E.5    Wagner, D.6
  • 9
    • 33646711601 scopus 로고    scopus 로고
    • Arterial pulse power analysis: The LiDCO™ plus system
    • Pinsky MR, Payen D, eds. Berlin, Germany: Springer Verlag; Update in Intensive Care and Emergency Medicine 42
    • Rhodes A, Sunderland R. Arterial pulse power analysis: the LiDCO™ plus system. In: Pinsky MR, Payen D, eds. Functional Hemodynamic Monitoring. Berlin, Germany: Springer Verlag; 2005:183-192. Update in Intensive Care and Emergency Medicine 42.
    • (2005) Functional Hemodynamic Monitoring. , pp. 183-192
    • Rhodes, A.1    Sunderland, R.2
  • 10
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac output determination from the arterial pressure wave clinical testing of a novel algorithm that does not require calibration
    • Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007;21:3-7.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 3-7
    • Manecke Jr., G.R.1    Auger, W.R.2
  • 11
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008;106: 1480-1486.
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Vallet, A.4    Cochard, J.F.5    Revel, P.6    Sztark, F.7
  • 12
    • 57349199888 scopus 로고    scopus 로고
    • Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
    • Biancofiore G, Critchley LA, Lee A, Bindi L, Bisa M, Esposito M, et al. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth 2009;102:47-54.
    • (2009) Br J Anaesth , vol.102 , pp. 47-54
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3    Bindi, L.4    Bisa, M.5    Esposito, M.6
  • 13
    • 38849093827 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs. lithium dilution technique
    • Costa MG, Della Rocca G, Chiarandini P, Mattelig S, Pompei L, Barriga MS, et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2008;34:257-263.
    • (2008) Intensive Care Med , vol.34 , pp. 257-263
    • Costa, M.G.1    Della Rocca, G.2    Chiarandini, P.3    Mattelig, S.4    Pompei, L.5    Barriga, M.S.6
  • 14
    • 0036800148 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A clinical assessment of central venous and peripheral venous indicator injection
    • Garcia-Rodriguez C, Pittman J, Cassell CH, Sum-Ping J, El-Moalem H, Young C, Mark JB. Lithium dilution cardiac output measurement: a clinical assessment of central venous and peripheral venous indicator injection. Crit Care Med 2002;30:2199-2204. (Pubitemid 35191567)
    • (2002) Critical Care Medicine , vol.30 , Issue.10 , pp. 2199-2204
    • Garcia-Rodriguez, C.1    Pittman, J.2    Cassell, C.H.3    Sum-Ping, J.4    El-Moalem, H.5    Young, C.6    Mark, J.B.7
  • 15
    • 0033503137 scopus 로고    scopus 로고
    • A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride
    • Jonas MM, Kelly FE, Linton RA, Band DM, O'Brien TK, Linton NW. A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride. J Clin Monit Comput 1999;15:525-528.
    • (1999) J Clin Monit Comput , vol.15 , pp. 525-528
    • Jonas, M.M.1    Kelly, F.E.2    Linton, R.A.3    Band, D.M.4    O'Brien, T.K.5    Linton, N.W.6
  • 16
    • 0027219058 scopus 로고
    • A new method of measuring cardiac output in man using lithium dilution
    • Linton RA, Band DM, Haire KM. A new method of measuring cardiac output in man using lithium dilution. Br J Anaesth 1993;71:262-266.
    • (1993) Br J Anaesth , vol.71 , pp. 262-266
    • Linton, R.A.1    Band, D.M.2    Haire, K.M.3
  • 17
    • 0030832772 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A comparison with thermodilution
    • Linton R, Band D, O'Brien T, Jonas M, Leach R. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med 1997;25: 1796-1800.
    • (1997) Crit Care Med , vol.25 , pp. 1796-1800
    • Linton, R.1    Band, D.2    O'Brien, T.3    Jonas, M.4    Leach, R.5
  • 18
    • 0030831649 scopus 로고    scopus 로고
    • Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
    • Kurita T, Morita K, Kato S, Kikura M, Horie M, Ikeda K. Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesth 1997;79: 770-775. (Pubitemid 27514069)
    • (1997) British Journal of Anaesthesia , vol.79 , Issue.6 , pp. 770-775
    • Kurita, T.1    Morita, K.2    Kato, S.3    Kikura, M.4    Horie, M.5    Ikeda, K.6
  • 19
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999;15:85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 20
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143:29-36. (Pubitemid 12142173)
    • (1982) Radiology , vol.143 , Issue.1 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 21
    • 0036920202 scopus 로고    scopus 로고
    • Hyperdynamic circulation in liver cirrhosis: Not peripheral vasodilatation but 'splanchnic steal'
    • Newby DE, Hayes PC. Hyperdynamic circulation in liver cirrhosis: not peripheral vasodilatation but 'splanchnic steal'. QJM 2002;95:827-830.
    • (2002) QJM , vol.95 , pp. 827-830
    • Newby, D.E.1    Hayes, P.C.2
  • 22
    • 0036094487 scopus 로고    scopus 로고
    • Evaluation of the splanchnic circulation with indocyanine green pharmacokinetics in liver transplant patients
    • Niemann CU, Yost CS, Mandell S, Henthorn TK. Evaluation of the splanchnic circulation with indocyanine green pharmacokinetics in liver transplant patients. Liver Transpl 2002;8:476-481.
    • (2002) Liver Transpl , vol.8 , pp. 476-481
    • Niemann, C.U.1    Yost, C.S.2    Mandell, S.3    Henthorn, T.K.4
  • 23
    • 41549163951 scopus 로고    scopus 로고
    • A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
    • Cecconi M, Fawcett J, Grounds RM, Rhodes A. A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008;8:3.
    • (2008) BMC Anesthesiol , vol.8 , pp. 3
    • Cecconi, M.1    Fawcett, J.2    Grounds, R.M.3    Rhodes, A.4
  • 24
    • 65649112876 scopus 로고    scopus 로고
    • Continuous arterial pressure waveform-based cardiac output using the Flo-Trac/FloTrac-Vigileo: A review and meta-analysis
    • Meyer J, Boldt J, Poland R, Peterson A, Manecke GR. Continuous arterial pressure waveform-based cardiac output using the Flo-Trac/FloTrac-Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth 2009;23:401-406.
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 401-406
    • Meyer, J.1    Boldt, J.2    Poland, R.3    Peterson, A.4    Manecke, G.R.5
  • 25
    • 34548266524 scopus 로고    scopus 로고
    • Clinical evaluation of the FloTrac/FloTrac-Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    • Button D, Weibel L, Reuthebuch O, Genoni M, Zollinger A, Hofer CK. Clinical evaluation of the FloTrac/FloTrac-Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007;99:329-336.
    • (2007) Br J Anaesth , vol.99 , pp. 329-336
    • Button, D.1    Weibel, L.2    Reuthebuch, O.3    Genoni, M.4    Zollinger, A.5    Hofer, C.K.6
  • 26
    • 36448936056 scopus 로고    scopus 로고
    • Evaluation of an improved algorithm for arterial pressure-based cardiac output assessment without external calibration [7]
    • DOI 10.1007/s00134-007-0859-9
    • Prasser C, Trabold B, Schwab A, Keyl C, Ziegler S, Wiesenack C. Evaluation of an improved algorithm for arterial pressure-based cardiac output assessment without external calibration. Intensive Care Med 2007;33: 2223-2225. (Pubitemid 350164566)
    • (2007) Intensive Care Medicine , vol.33 , Issue.12 , pp. 2223-2225
    • Prasser, C.1    Trabold, B.2    Schwab, A.3    Keyl, C.4    Ziegler, S.5    Wiesenack, C.6
  • 28
    • 34250372951 scopus 로고    scopus 로고
    • Comparison of femoral arterial blood pressure with radial arterial blood pressure and noninvasive upper arm blood pressure in the reperfusion period during liver transplantation
    • Shin BS, Kim GS, Ko JS, Gwak MS, Yang CS, Hahm TS, Lee S-K. Comparison of femoral arterial blood pressure with radial arterial blood pressure and noninvasive upper arm blood pressure in the reperfusion period during liver transplantation. Transplant Proc 2007;39: 1326-1328.
    • (2007) Transplant Proc , vol.39 , pp. 1326-1328
    • Shin, B.S.1    Kim, G.S.2    Ko, J.S.3    Gwak, M.S.4    Yang, C.S.5    Hahm, T.S.6    Lee, S.-K.7
  • 29
    • 20644447575 scopus 로고    scopus 로고
    • New technologies for measuring cardiac output: The future?
    • Rhodes A, Grounds RM. New technologies for measuring cardiac output: the future? Curr Opin Crit Care 2005; 11:224-226.
    • (2005) Curr Opin Crit Care , vol.11 , pp. 224-226
    • Rhodes, A.1    Grounds, R.M.2
  • 30
    • 0035064663 scopus 로고    scopus 로고
    • Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb
    • Linton NW, Linton RA. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001;86:486-496.
    • (2001) Br J Anaesth , vol.86 , pp. 486-496
    • Linton, N.W.1    Linton, R.A.2
  • 31
    • 0021076099 scopus 로고
    • Cardiac output by thermodilution technique. Effect of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient
    • Elkayam U, Berkley R, Azen S, Weber L, Geva B, Henry WL. Cardiac output by thermodilution technique. Effect of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient. Chest 1983;84: 418-422.
    • (1983) Chest , vol.84 , pp. 418-422
    • Elkayam, U.1    Berkley, R.2    Azen, S.3    Weber, L.4    Geva, B.5    Henry, W.L.6
  • 32
    • 0026628714 scopus 로고
    • Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass
    • Bazaral MG, Petre J, Novoa R. Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 1992;77:31-33.
    • (1992) Anesthesiology , vol.77 , pp. 31-33
    • Bazaral, M.G.1    Petre, J.2    Novoa, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.