-
1
-
-
0020544528
-
Cyclic changes in arterial pulse during respiratory support
-
Jardin F, Farcot JC, Gueret P, et al: Cyclic changes in arterial pulse during respiratory support. Circulation 1983; 83:266-274
-
(1983)
Circulation
, vol.83
, pp. 266-274
-
-
Jardin, F.1
Farcot, J.C.2
Gueret, P.3
-
2
-
-
0032420373
-
Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients
-
Perel A: Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Anesthesiology 1998; 89:1309-1310
-
(1998)
Anesthesiology
, vol.89
, pp. 1309-1310
-
-
Perel, A.1
-
3
-
-
0023605206
-
Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
-
Perel A, Pizov R, Cotev S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987; 67:498-502
-
(1987)
Anesthesiology
, vol.67
, pp. 498-502
-
-
Perel, A.1
Pizov, R.2
Cotev, S.3
-
4
-
-
0032437998
-
Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
-
Tavernier B, Makhotine O, Lebuffe G, et al: Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89:1313-1321
-
(1998)
Anesthesiology
, vol.89
, pp. 1313-1321
-
-
Tavernier, B.1
Makhotine, O.2
Lebuffe, G.3
-
5
-
-
0033924592
-
Relation between respiratory changes in arterial pressure and fluid responsiveness in septic patients with acute circulatory failure
-
Michard F, Boussat S, Chemla D, et al: Relation between respiratory changes in arterial pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162:134-138
-
(2000)
Am J Respir Crit Care Med
, vol.162
, pp. 134-138
-
-
Michard, F.1
Boussat, S.2
Chemla, D.3
-
6
-
-
0000649849
-
Schätzung des Schlagvolumens des menschlichen Herzens aufgrund der Wellenund Windkesseltheorie
-
Frank O: Schätzung des Schlagvolumens des menschlichen Herzens aufgrund der Wellenund Windkesseltheorie. Z Biol 1930; 90:405
-
(1930)
Z Biol
, vol.90
, pp. 405
-
-
Frank, O.1
-
7
-
-
0014508574
-
Pressure-flow studies in man. An evaluation of the duration of the phases of systole
-
Harley A, Starmer CF, Greenfield JC Jr: Pressure-flow studies in man. An evaluation of the duration of the phases of systole. J Clin Invest 1969; 48:895-905
-
(1969)
J Clin Invest
, vol.48
, pp. 895-905
-
-
Harley, A.1
Starmer, C.F.2
Greenfield J.C., Jr.3
-
8
-
-
0002765004
-
A simple device for the continuous measurement of cardiac output
-
Wesseling KH, de Wit B, Weber JA, et al: A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Phys 1983; 5:16-52
-
(1983)
Adv Cardiovasc Phys
, vol.5
, pp. 16-52
-
-
Wesseling, K.H.1
De Wit, B.2
Weber, J.A.3
-
9
-
-
0032734448
-
Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
-
Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al: Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution. Crit Care Med 1999; 27:2407-2412
-
(1999)
Crit Care Med
, vol.27
, pp. 2407-2412
-
-
Goedje, O.1
Hoeke, K.2
Lichtwarck-Aschoff, M.3
-
10
-
-
0036152801
-
Reliability of a new algorithm for continuous cardiac output determination by pulse contour analysis during hemodynamic instability
-
Goedje O, Hoeke K, Goetz AE, et al: Reliability of a new algorithm for continuous cardiac output determination by pulse contour analysis during hemodynamic instability. Crit Care Med 2002; 30:52-59
-
(2002)
Crit Care Med
, vol.30
, pp. 52-59
-
-
Goedje, O.1
Hoeke, K.2
Goetz, A.E.3
-
11
-
-
0036095676
-
Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm
-
Felbinger TW, Reuter DA, Eltzschig HK, et al: Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm. J Clin Anesth 2002; 14:296-301
-
(2002)
J Clin Anesth
, vol.14
, pp. 296-301
-
-
Felbinger, T.W.1
Reuter, D.A.2
Eltzschig, H.K.3
-
12
-
-
0036137453
-
Optimising fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations: A comparison to aortic systolic pressure variations
-
Reuter DA, Felbinger TW, Kilger E, et al: Optimising fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations: A comparison to aortic systolic pressure variations. Br J Anaesth 2002; 88:124-126
-
(2002)
Br J Anaesth
, vol.88
, pp. 124-126
-
-
Reuter, D.A.1
Felbinger, T.W.2
Kilger, E.3
-
13
-
-
0035080242
-
Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
-
Berkenstadt C, Margalit N, Hadani M, et al: Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001; 92:984-989
-
(2001)
Anesth Analg
, vol.92
, pp. 984-989
-
-
Berkenstadt, C.1
Margalit, N.2
Hadani, M.3
-
14
-
-
0036219991
-
Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
-
Reuter DA, Felbinger TW, Schmidt C, et al: Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28:392-398
-
(2002)
Intensive Care Med
, vol.28
, pp. 392-398
-
-
Reuter, D.A.1
Felbinger, T.W.2
Schmidt, C.3
-
15
-
-
0028334544
-
Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery
-
Hoeft A, Schorn B, Weyland A, et al: Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery. Anesthesiology 1994; 81:76-86
-
(1994)
Anesthesiology
, vol.81
, pp. 76-86
-
-
Hoeft, A.1
Schorn, B.2
Weyland, A.3
-
16
-
-
0025209848
-
Comparison of transesophageal echocardiographic and scintigraphic estimates of left ventricular end-diastolic volume index and ejection fraction in patients following coronary artery bypass grafting
-
Urbanowicz JH, Shaaban MJ, Cohen NH, et al: Comparison of transesophageal echocardiographic and scintigraphic estimates of left ventricular end-diastolic volume index and ejection fraction in patients following coronary artery bypass grafting. Anesthesiology 1990; 72:607-612
-
(1990)
Anesthesiology
, vol.72
, pp. 607-612
-
-
Urbanowicz, J.H.1
Shaaban, M.J.2
Cohen, N.H.3
-
17
-
-
0022446919
-
Validation of quantitative intraoperative transesophageal echocardiography
-
Konstadt SN, Thys D, Mindich BP, et al: Validation of quantitative intraoperative transesophageal echocardiography. Anesthesiology 1986; 65:418-421
-
(1986)
Anesthesiology
, vol.65
, pp. 418-421
-
-
Konstadt, S.N.1
Thys, D.2
Mindich, B.P.3
-
18
-
-
0036174275
-
Transesophageal echocardiography: Perioperative evaluation of valvular function
-
Eltzschig HK, Goetz AE, Schroeder TH, et al: Transesophageal echocardiography: Perioperative evaluation of valvular function. Anaesthesist 2002; 51:81-102
-
(2002)
Anaesthesist
, vol.51
, pp. 81-102
-
-
Eltzschig, H.K.1
Goetz, A.E.2
Schroeder, T.H.3
-
19
-
-
0036258148
-
American Society of Echocardiography and Society of Cardiovascular Anesthesiologists task force guidelines for training in perioperative echocardiography
-
Cahalan MK, Abel M, Goldman M, et al: American Society of Echocardiography and Society of Cardiovascular Anesthesiologists task force guidelines for training in perioperative echocardiography. Anesth Analg 2002; 94:1384-1388
-
(2002)
Anesth Analg
, vol.94
, pp. 1384-1388
-
-
Cahalan, M.K.1
Abel, M.2
Goldman, M.3
-
20
-
-
0020083498
-
The meaning and use of the area under a receiver operating characteristic (ROC) curve
-
Hanley JA, McNeil BJ: The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982; 143:29-36
-
(1982)
Radiology
, vol.143
, pp. 29-36
-
-
Hanley, J.A.1
McNeil, B.J.2
-
21
-
-
0020524559
-
A method of comparing the areas under receiver operating characteristic curves derived from the same cases
-
Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983; 148:839-843
-
(1983)
Radiology
, vol.148
, pp. 839-843
-
-
Hanley, J.A.1
McNeil, B.J.2
-
22
-
-
0032988086
-
Clinical use of changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
-
Michard F, Boussat S, Chemla D, et al: Clinical use of changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 1999; 159:935-939
-
(1999)
Am J Respir Crit Care Med
, vol.159
, pp. 935-939
-
-
Michard, F.1
Boussat, S.2
Chemla, D.3
-
23
-
-
0036283553
-
Predicting fluid responsiveness in ICU patients: A critical analysis of evidence
-
Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: A critical analysis of evidence: Chest 2002; 121:2000-2008
-
(2002)
Chest
, vol.121
, pp. 2000-2008
-
-
Michard, F.1
Teboul, J.L.2
-
24
-
-
0032913033
-
Contraction-relaxation coupling and impaired left ventricular performance in coronary surgery patients
-
De Hert SG, Gillebert TC, Ten Broecke PW, et al: Contraction-relaxation coupling and impaired left ventricular performance in coronary surgery patients. Anesthesiology 1999; 90:748-757
-
(1999)
Anesthesiology
, vol.90
, pp. 748-757
-
-
De Hert, S.G.1
Gillebert, T.C.2
Ten Broecke, P.W.3
-
25
-
-
0028288427
-
The failing human heart is unable to use the Frank-Starling mechanism
-
Schwinger RH, Böhm M, Koch A, et al: The failing human heart is unable to use the Frank-Starling mechanism. Circ Res 1994; 74:959-969
-
(1994)
Circ Res
, vol.74
, pp. 959-969
-
-
Schwinger, R.H.1
Böhm, M.2
Koch, A.3
-
26
-
-
0029965043
-
Transesophageal echocardiography: An objective tool in defining maximum ventricular response to intravenous fluid therapy
-
Swenson JD, Harkin C, Pace NL, et al: Transesophageal echocardiography: An objective tool in defining maximum ventricular response to intravenous fluid therapy. Anesth Analg 1996; 83:1149-1153
-
(1996)
Anesth Analg
, vol.83
, pp. 1149-1153
-
-
Swenson, J.D.1
Harkin, C.2
Pace, N.L.3
-
27
-
-
0028100054
-
Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function
-
Cheung AT, Savino JS, Weiss SJ, et al: Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function. Anesthesiology 1994; 81:376-387
-
(1994)
Anesthesiology
, vol.81
, pp. 376-387
-
-
Cheung, A.T.1
Savino, J.S.2
Weiss, S.J.3
|