메뉴 건너뛰기




Volumn 56, Issue 1, 2009, Pages 182-192

Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame

Author keywords

[No Author keywords available]

Indexed keywords

2-D ARRAYS; A CENTERS; AMPLITUDE DISTRIBUTIONS; ARRAY ELEMENTS; BULK SILICONS; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS; CHIP BONDINGS; CONDUCTIVE SILICONS; DEVICE LAYERS; ELECTRICAL CONNECTIONS; ELECTRICAL INTERCONNECTS; FRACTIONAL BAND WIDTHS; FRAME STRUCTURES; MECHANICAL SUPPORTS; ON WAFERS; PULSE ECHOES; SILICON ON INSULATORS; SILICON PILLARS; SUPPORTING FRAMES; THROUGH-WAFER VIAS; TRANSDUCER SURFACES; TRENCH ISOLATIONS; ULTRASOUND IMAGING; VIA FABRICATIONS; VIABLE SOLUTIONS;

EID: 60349099308     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2009.1018     Document Type: Article
Times cited : (35)

References (48)
  • 1
    • 21644450947 scopus 로고    scopus 로고
    • Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays
    • D. M. Mills, "Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays," in Proc. IEEE Ultrasonics Symp., 2004, pp. 384-390.
    • (2004) Proc. IEEE Ultrasonics Symp , pp. 384-390
    • Mills, D.M.1
  • 3
    • 33645065119 scopus 로고    scopus 로고
    • Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
    • Feb
    • F. L. Degertekin, R. O. Guldiken, and M. Karaman, "Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 2, pp. 474-482, Feb. 2006.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , Issue.2 , pp. 474-482
    • Degertekin, F.L.1    Guldiken, R.O.2    Karaman, M.3
  • 4
    • 33746809101 scopus 로고    scopus 로고
    • 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications
    • Jun
    • D. T. Yeh, O. Oralkan, I. O. Wygant, M. O'Donnell, and B. T. Khuri-Yakub, "3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 6, pp. 1202-1211, Jun. 2006.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , Issue.6 , pp. 1202-1211
    • Yeh, D.T.1    Oralkan, O.2    Wygant, I.O.3    O'Donnell, M.4    Khuri-Yakub, B.T.5
  • 9
    • 60349090548 scopus 로고    scopus 로고
    • Fabrication of flexible transducer arrays with through-wafer electrical interconnects based on trench refilling with PDMS
    • Apr
    • X. Zhuang, D.-S. Lin, O. Oralkan, and B. T. Khuri-Yakub, "Fabrication of flexible transducer arrays with through-wafer electrical interconnects based on trench refilling with PDMS," IEEE/ASME J. Microelectromech. Syst., vol. 17, pp. 446-452, Apr. 2008.
    • (2008) IEEE/ASME J. Microelectromech. Syst , vol.17 , pp. 446-452
    • Zhuang, X.1    Lin, D.-S.2    Oralkan, O.3    Khuri-Yakub, B.T.4
  • 12
    • 43349106944 scopus 로고    scopus 로고
    • Advantages of capacitive micromachined ultrasonics transducers (CMUTs) for high intensity focused ultrasound (HIFU)
    • S. H. Wong, M. Kupnik, K. Butts-Pauly, and B. T. Khuri-Yakub, "Advantages of capacitive micromachined ultrasonics transducers (CMUTs) for high intensity focused ultrasound (HIFU)," in Proc. IEEE Ultrasonics Symp., 2007, pp. 1313-1316.
    • (2007) Proc. IEEE Ultrasonics Symp , pp. 1313-1316
    • Wong, S.H.1    Kupnik, M.2    Butts-Pauly, K.3    Khuri-Yakub, B.T.4
  • 14
    • 33645068877 scopus 로고    scopus 로고
    • CMUTS with dual electrode structure for improved transmit and receive performance
    • Feb
    • R. O. Guldiken, J. McLean, and F. L. Degertekin, "CMUTS with dual electrode structure for improved transmit and receive performance," IEEE Trans. Ultrason. Eerroelectr. Freq. Control, vol. 53, no. 2, pp. 483-491, Feb. 2006.
    • (2006) IEEE Trans. Ultrason. Eerroelectr. Freq. Control , vol.53 , Issue.2 , pp. 483-491
    • Guldiken, R.O.1    McLean, J.2    Degertekin, F.L.3
  • 16
    • 33847169475 scopus 로고    scopus 로고
    • Improving the performance of capacitive micromachined ultrasound transducers using modified membrane and support structures
    • S. Zhou, P. Reynolds, and J. A. Hossack, "Improving the performance of capacitive micromachined ultrasound transducers using modified membrane and support structures," in Proc. IEEE Ultrasonics Symp., 2005, pp. 1925-1928.
    • (2005) Proc. IEEE Ultrasonics Symp , pp. 1925-1928
    • Zhou, S.1    Reynolds, P.2    Hossack, J.A.3
  • 17
    • 39649099361 scopus 로고    scopus 로고
    • Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts
    • Mar
    • Y. Huang, X. Zhuang, E. O. Haeggstrom, A. S. Ergun, C.-H. Cheng, and B. T. Khuri-Yakub, "Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts," Ultrasonics, vol. 48, no. 1, pp. 74-81, Mar. 2008.
    • (2008) Ultrasonics , vol.48 , Issue.1 , pp. 74-81
    • Huang, Y.1    Zhuang, X.2    Haeggstrom, E.O.3    Ergun, A.S.4    Cheng, C.-H.5    Khuri-Yakub, B.T.6
  • 19
    • 0035731025 scopus 로고    scopus 로고
    • Cost-effective and manufacturable route to the fabrication of high-density 2D micromachined ultrasonic transducer arrays and (CMOS) signal conditioning electronics on the same silicon substrate
    • R. A. Noble, R. R. Davies, M. M. Day, L. Koker, D. O. King, K. M. Brunson, A. R. D. Jones, J. S. Mcintosh, D. A. Hutchins, T. J. Robertson, and P. Saul, "Cost-effective and manufacturable route to the fabrication of high-density 2D micromachined ultrasonic transducer arrays and (CMOS) signal conditioning electronics on the same silicon substrate," in Proc. IEEE Ultrasonics Symp., 2001, pp. 941-944.
    • (2001) Proc. IEEE Ultrasonics Symp , pp. 941-944
    • Noble, R.A.1    Davies, R.R.2    Day, M.M.3    Koker, L.4    King, D.O.5    Brunson, K.M.6    Jones, A.R.D.7    Mcintosh, J.S.8    Hutchins, D.A.9    Robertson, T.J.10    Saul, P.11
  • 21
    • 21644470582 scopus 로고    scopus 로고
    • Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics
    • C. Daft, S. Calmes, D. da Graca, K. Patel, P. Wagner, and I. Ladabaum, "Microfabricated ultrasonic transducers monolithically integrated with high voltage electronics," in Proc. IEEE Ultrasonics Symp., 2004. pp. 493-496.
    • (2004) Proc. IEEE Ultrasonics Symp , pp. 493-496
    • Daft, C.1    Calmes, S.2    da Graca, D.3    Patel, K.4    Wagner, P.5    Ladabaum, I.6
  • 22
    • 0034579981 scopus 로고    scopus 로고
    • An efficient electrical addressing method using throughwafer vias for two-dimensional ultrasonic arrays
    • C. H. Cheng, E. M. Chow, X. Jin, A. S. Ergun, and B. T. Khuri-Yakub, "An efficient electrical addressing method using throughwafer vias for two-dimensional ultrasonic arrays," in Proc. IEEE Ultrasonics Symp., 2000, pp. 1179-1182.
    • (2000) Proc. IEEE Ultrasonics Symp , pp. 1179-1182
    • Cheng, C.H.1    Chow, E.M.2    Jin, X.3    Ergun, A.S.4    Khuri-Yakub, B.T.5
  • 25
    • 34347216702 scopus 로고    scopus 로고
    • Integration of trench-isolated through-wafer interconnects with 2D capacitive micromachined ultrasonic transducer arrays
    • Jul
    • X. Zhuang, A. S. Ergun, Y. Huang, I. O. Wygant, O. Oralkan, and B. T. Khuri-Yakub, "Integration of trench-isolated through-wafer interconnects with 2D capacitive micromachined ultrasonic transducer arrays," Sens. Actuators A Phys., vol. 138, no. 1, pp. 221-229, Jul. 2007.
    • (2007) Sens. Actuators A Phys , vol.138 , Issue.1 , pp. 221-229
    • Zhuang, X.1    Ergun, A.S.2    Huang, Y.3    Wygant, I.O.4    Oralkan, O.5    Khuri-Yakub, B.T.6
  • 26
    • 48149096016 scopus 로고    scopus 로고
    • Characterization of fabrication related gap-height variations in capacitive micromachined ultrasonic transducers
    • D.-S. Lin, X. Zhuang, S. H. Wong, A. S. Ergun, M. Kupnik, and B. T. Khuri-Yakub, "Characterization of fabrication related gap-height variations in capacitive micromachined ultrasonic transducers," in Proc. IEEE Ultrasonics Symp., 2007, pp. 523-526.
    • (2007) Proc. IEEE Ultrasonics Symp , pp. 523-526
    • Lin, D.-S.1    Zhuang, X.2    Wong, S.H.3    Ergun, A.S.4    Kupnik, M.5    Khuri-Yakub, B.T.6
  • 29
    • 33644868274 scopus 로고    scopus 로고
    • Linear and nonlinear equivalent circuit modeling of CMUTs
    • Dec
    • A. Lohfink and P. C. Eccardt, "Linear and nonlinear equivalent circuit modeling of CMUTs," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 12, pp. 2163-2172, Dec. 2005.
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , Issue.12 , pp. 2163-2172
    • Lohfink, A.1    Eccardt, P.C.2
  • 30
    • 0033294633 scopus 로고    scopus 로고
    • 3D simulation of controlled micromachined capacitive ultrasound transducers
    • M. Kaltenbacher, H. Landes, K. Niederer, and R. Lerch, "3D simulation of controlled micromachined capacitive ultrasound transducers," in Proc. IEEE Ultrasonics Symp., 1999, pp. 1155-1158.
    • (1999) Proc. IEEE Ultrasonics Symp , pp. 1155-1158
    • Kaltenbacher, M.1    Landes, H.2    Niederer, K.3    Lerch, R.4
  • 34
    • 33644855948 scopus 로고    scopus 로고
    • Acoustic coupling in capacitive microfabricated ultrasonic transducers: Modeling and experiments
    • Dec
    • A. Caronti, A. Savoia, G. Caliano, and M. Pappaiardo, "Acoustic coupling in capacitive microfabricated ultrasonic transducers: Modeling and experiments," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 12, pp. 2220-2234, Dec. 2005.
    • (2005) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.52 , Issue.12 , pp. 2220-2234
    • Caronti, A.1    Savoia, A.2    Caliano, G.3    Pappaiardo, M.4
  • 36
    • 34347209900 scopus 로고    scopus 로고
    • Reducing inter-element acoustic crosstalk in capacitive micromachined ultrasound transducers
    • Jun
    • S. Zhou and J. A. Hossack, "Reducing inter-element acoustic crosstalk in capacitive micromachined ultrasound transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 6, pp. 1217-1228, Jun. 2007.
    • (2007) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.54 , Issue.6 , pp. 1217-1228
    • Zhou, S.1    Hossack, J.A.2
  • 40
    • 33645054820 scopus 로고    scopus 로고
    • Etch characteristics of KOH, TMAH and dual doped TMAH for bulk micromachining of silicon
    • K. Biswas and S. Kal, "Etch characteristics of KOH, TMAH and dual doped TMAH for bulk micromachining of silicon," Microelectron. J., vol. 37, pp. 519-525, 2006.
    • (2006) Microelectron. J , vol.37 , pp. 519-525
    • Biswas, K.1    Kal, S.2
  • 42
    • 0003950677 scopus 로고    scopus 로고
    • Method of anisotropically etching silicon,
    • U.S. Patent 5,501,893 to Robert Bosch GmbH, Mar. 1996
    • F. Laermer and A. Schilp, "Method of anisotropically etching silicon," U.S. Patent 5,501,893 to Robert Bosch GmbH, Mar. 1996.
    • Laermer, F.1    Schilp, A.2
  • 44
    • 60349084488 scopus 로고    scopus 로고
    • Ultrasound transducers with improved focus in the elevation direction,
    • U.S. Patent application 20070016065, Jan
    • H. Hastings and S. L. Roth, "Ultrasound transducers with improved focus in the elevation direction," U.S. Patent application 20070016065, Jan. 2007.
    • (2007)
    • Hastings, H.1    Roth, S.L.2
  • 47
    • 21644445650 scopus 로고    scopus 로고
    • Analytical calculation of collapse voltage of CMUT membrane [capacitive micromachined ultrasonic transducers]
    • A. Nikoozadeh, B. Bayram, G. G. Yaralioglu, and B. T. Khuri-Yakub, "Analytical calculation of collapse voltage of CMUT membrane [capacitive micromachined ultrasonic transducers]," in Proc. IEEE Ultrasonics Symp., 2004, pp. 256-259.
    • (2004) Proc. IEEE Ultrasonics Symp , pp. 256-259
    • Nikoozadeh, A.1    Bayram, B.2    Yaralioglu, G.G.3    Khuri-Yakub, B.T.4
  • 48
    • 15044352366 scopus 로고    scopus 로고
    • Osirix: An open-source software for navigating in multidimensional DICOM images
    • Sep
    • A. Rosset, L. Spadola, and O. Ratib, "Osirix: An open-source software for navigating in multidimensional DICOM images," J. Digit. Imaging, vol. 17, no. 3, pp. 205-216, Sep. 2004
    • (2004) J. Digit. Imaging , vol.17 , Issue.3 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.