메뉴 건너뛰기




Volumn , Issue , 2007, Pages 900-903

Fully integrated CMUT-based forward-looking intracardiac imaging for electrophysiology

Author keywords

Capacitive micromachined ultrasonic transducers; CMUT; Electrophysiology; Forward looking; Guidance; Intracardiac echo; Ultrasound

Indexed keywords

BOND PADS; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCER; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS; CARDIAC ARRHYTHMIAS; CMUT; FEATURE SIZES; FLEXIBLE PRINTED CIRCUIT BOARD; FLIP CHIPPING; FORWARD LOOKING; FRACTIONAL BANDWIDTH; FRAME RATES; FRONT-END ELECTRONICS; FULLY INTEGRATED; GUIDANCE; IMAGING PERFORMANCE; IMPROVED SNR; INITIAL TESTING; INTRACARDIAC ECHO; INTRACARDIAC IMAGING; LINE DRIVERS; MEAN VALUE; MINIMALLY INVASIVE; RESONANT FREQUENCIES; RF ABLATION; STANDARD DEVIATION; SUB-ASSEMBLY; TRANSIMPEDANCE PREAMPLIFIERS; ULTRASOUND; ULTRASOUND IMAGING; ULTRASOUND IMAGING SYSTEMS; UNI-POLAR PULSING;

EID: 48149103194     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2007.230     Document Type: Conference Paper
Times cited : (9)

References (7)
  • 1
    • 21044434161 scopus 로고    scopus 로고
    • Clinical applications of intracardiac echocardiography in interventional procedures
    • M. Jongbloed, M. Schalij, K. Zeppenfeld, P. Oemrawsingh, E. van der Wall, J. Bax, "Clinical applications of intracardiac echocardiography in interventional procedures," Heart, vol. 91, pp. 981-990, 2005.
    • (2005) Heart , vol.91 , pp. 981-990
    • Jongbloed, M.1    Schalij, M.2    Zeppenfeld, K.3    Oemrawsingh, P.4    van der Wall, E.5    Bax, J.6
  • 2
    • 0035832261 scopus 로고    scopus 로고
    • Prevalence of diagnosed atrial fibrillation in adults: National implications for rhythm management andstroke prevention: the anticoagulation and risk factors in AF (ATRIA) study
    • Go AS, Hylek EM, Phillips KA, et al., "Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management andstroke prevention: the anticoagulation and risk factors in AF (ATRIA) study," JAMA., vol. 285, pp. 2370-5, 2001.
    • (2001) JAMA , vol.285 , pp. 2370-2375
    • Go, A.S.1    Hylek, E.M.2    Phillips, K.A.3
  • 3
    • 33646724251 scopus 로고    scopus 로고
    • Radiofrequency ablation of arrhythmias guided by non-fluoroscopic cathter location: A prospective randomized trial
    • M. Earley, et al., "Radiofrequency ablation of arrhythmias guided by non-fluoroscopic cathter location: a prospective randomized trial," European Heart Journal, vol. 27, pp. 1223-1229, 2006.
    • (2006) European Heart Journal , vol.27 , pp. 1223-1229
    • Earley, M.1
  • 4
    • 0036159331 scopus 로고    scopus 로고
    • Nonfluoroscopic magnetic electroanatomic mapping to facilitate local pulmonary veins ablation for paroxysmal Atrial Fibrillation
    • Jan
    • T. Hung-Fat, "Nonfluoroscopic magnetic electroanatomic mapping to facilitate local pulmonary veins ablation for paroxysmal Atrial Fibrillation," Journal of Pacing and Clinical Electrophysiology, vol. 25, no. 1, Jan. 2002.
    • (2002) Journal of Pacing and Clinical Electrophysiology , vol.25 , Issue.1
    • Hung-Fat, T.1
  • 5
    • 0034711170 scopus 로고    scopus 로고
    • Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter, a prospective randomized study
    • H. Kottkamp, et al., "Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter, a prospective randomized study," Circulation, vol. 102, pp. 2082-2086, 2000.
    • (2000) Circulation , vol.102 , pp. 2082-2086
    • Kottkamp, H.1
  • 6
    • 28944437901 scopus 로고    scopus 로고
    • Fluoroscopically Guided Implantation of Modern Cardiac Resynchronization Devices
    • Perisinakis, et al., "Fluoroscopically Guided Implantation of Modern Cardiac Resynchronization Devices," Journal of the American College of Cardiology, vol. 46, no. 12, pp. 2235-2239, 2005.
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.12 , pp. 2235-2239
    • Perisinakis1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.