메뉴 건너뛰기




Volumn 15, Issue 5, 2015, Pages 459-468

Advances in process monitoring tools for cell culture bioprocesses

Author keywords

Bioreactor monitoring; Mammalian cell bioprocess; Process analytical technology; Process control; Sensor

Indexed keywords

CELL CULTURE; CELLS; MAMMALS; MONITORING; PROCESS MONITORING; SENSORS; SPECTROMETRY;

EID: 84935721616     PISSN: 16180240     EISSN: 16182863     Source Type: Journal    
DOI: 10.1002/elsc.201500006     Document Type: Review
Times cited : (65)

References (76)
  • 2
    • 78649926584 scopus 로고    scopus 로고
    • Chracterization and analysis of biopharmaceutical proteins
    • Luo, Y., Matejic, T., Ng, C.-K., Nunnally, B. et al., Chracterization and analysis of biopharmaceutical proteins. Sep. Sci. Technol. 2011, 10, 283-359.
    • (2011) Sep. Sci. Technol. , vol.10 , pp. 283-359
    • Luo, Y.1    Matejic, T.2    Ng, C.-K.3    Nunnally, B.4
  • 3
    • 77956257160 scopus 로고    scopus 로고
    • Control of misincorporation of serine for asparagine during antibody production using CHO cells
    • Khetan, A., Huang, Y. M., Dolnikova, J., Pederson, N. E. et al., Control of misincorporation of serine for asparagine during antibody production using CHO cells. Biotechnol. Bioeng. 2010, 1071, 116-123.
    • (2010) Biotechnol. Bioeng , vol.1071 , pp. 116-123
    • Khetan, A.1    Huang, Y.M.2    Dolnikova, J.3    Pederson, N.E.4
  • 4
    • 70349949073 scopus 로고    scopus 로고
    • Advances in on-line monitoring and control of mammalian cell cultures: Supporting the PAT initiative
    • Teixeira, A., Oliveira, R., Alves, P., Carrondo, M., Advances in on-line monitoring and control of mammalian cell cultures: Supporting the PAT initiative. Biotechnol. Adv. 2009, 276, 726-732.
    • (2009) Biotechnol. Adv. , vol.276 , pp. 726-732
    • Teixeira, A.1    Oliveira, R.2    Alves, P.3    Carrondo, M.4
  • 5
    • 84904341038 scopus 로고    scopus 로고
    • Towards real-time monitoring of therapeutic protein quality in mammalian cell processes
    • Pais, D. A., Carrondo, M. J., Alves, P. M., Teixeira, A. P., Towards real-time monitoring of therapeutic protein quality in mammalian cell processes. Curr. Opin. Biotechnol. 2014, 30, 161-167.
    • (2014) Curr. Opin. Biotechnol , vol.30 , pp. 161-167
    • Pais, D.A.1    Carrondo, M.J.2    Alves, P.M.3    Teixeira, A.P.4
  • 6
    • 84877013068 scopus 로고    scopus 로고
    • Process analytical technology (PAT) tools for the cultivation step in biopharmaceutical production
    • Streefland, M., Martens, D. E., Beuvery, E. C., Wijffels, R. H., Process analytical technology (PAT) tools for the cultivation step in biopharmaceutical production. Eng. Life Sci. 2013, 133, 212-223.
    • (2013) Eng. Life Sci. , vol.133 , pp. 212-223
    • Streefland, M.1    Martens, D.E.2    Beuvery, E.C.3    Wijffels, R.H.4
  • 7
    • 0023163941 scopus 로고
    • Low-cost computer-coupled fermentor off-gas analysis via quadrupole mass spectrometer
    • Coppella, S. J. and Dhurjati, P., Low-cost computer-coupled fermentor off-gas analysis via quadrupole mass spectrometer. Biotechnol. Bioeng. 1987, 296, 679-689.
    • (1987) Biotechnol. Bioeng. , vol.296 , pp. 679-689
    • Coppella, S.J.1    Dhurjati, P.2
  • 8
    • 67650898837 scopus 로고    scopus 로고
    • Techniques for oxygen transfer measurement in bioreactors: A review
    • Suresh, S., Srivastava, V. C., Mishra, I. M., Techniques for oxygen transfer measurement in bioreactors: A review. J. Chem. Technol. Biotechnol. 2009, 848, 1091-1103.
    • (2009) J. Chem. Technol. Biotechnol. , vol.848 , pp. 1091-1103
    • Suresh, S.1    Srivastava, V.C.2    Mishra, I.M.3
  • 9
    • 0025899513 scopus 로고
    • Monitoring of substrates and products duringfed-batch penicillin fermentations on complex media
    • Christensen, L. H., Nielsen, J., Villadsen, J., Monitoring of substrates and products duringfed-batch penicillin fermentations on complex media. Anal. Chim. Acta 1991, 249, 123-136.
    • (1991) Anal. Chim. Acta , vol.249 , pp. 123-136
    • Christensen, L.H.1    Nielsen, J.2    Villadsen, J.3
  • 10
    • 80053202599 scopus 로고    scopus 로고
    • Simplified off-gas analyses in animal cell cultures for process monitoring and control purposes
    • Aehle, M., Kuprijanov, A., Schaepe, S., Simutis, R., Lubbert, A., Simplified off-gas analyses in animal cell cultures for process monitoring and control purposes. Biotechnol. Lett. 2011, 3311, 2103-2110.
    • (2011) Biotechnol. Lett , vol.3311 , pp. 2103-2110
    • Aehle, M.1    Kuprijanov, A.2    Schaepe, S.3    Simutis, R.4    Lubbert, A.5
  • 11
    • 0029059493 scopus 로고
    • High viable cell concentration fed-batch cultures of hydriboma cells through on-line nutrient feeding
    • Zhou, W., Rehm, J., Hu, W. S., High viable cell concentration fed-batch cultures of hydriboma cells through on-line nutrient feeding. Biotechnol. Bioeng. 1995, 46, 579-587.
    • (1995) Biotechnol. Bioeng. , vol.46 , pp. 579-587
    • Zhou, W.1    Rehm, J.2    Hu, W.S.3
  • 12
    • 0028454939 scopus 로고
    • On-line characterization of a hybridoma cell culture process
    • Zhou, W. and Hu, W. S., On-line characterization of a hybridoma cell culture process. Biotechnol. Bioeng. 1994, 442, 170-177.
    • (1994) Biotechnol. Bioeng , vol.442 , pp. 170-177
    • Zhou, W.1    Hu, W.S.2
  • 13
    • 84868481008 scopus 로고    scopus 로고
    • Multivariate analysis of cell culture bioprocess data-lactate consumption as process indicator
    • Le, H., Kabbur, S., Pollastrini, L., Sun, Z. et al., Multivariate analysis of cell culture bioprocess data-lactate consumption as process indicator. J. Biotechnol. 2012, 162, 210-223.
    • (2012) J. Biotechnol , vol.162 , pp. 210-223
    • Le, H.1    Kabbur, S.2    Pollastrini, L.3    Sun, Z.4
  • 14
    • 81455141232 scopus 로고    scopus 로고
    • Comparative metabolite analysis to understand lactate metabolism shift in Chinese hamster ovary cell culture process
    • Luo, J., Vijayasankaran, N., Autsen, J., Santuray, R. et al., Comparative metabolite analysis to understand lactate metabolism shift in Chinese hamster ovary cell culture process. Biotechnol. Bioeng. 2012, 1091, 146-156.
    • (2012) Biotechnol. Bioeng. , vol.1091 , pp. 146-156
    • Luo, J.1    Vijayasankaran, N.2    Autsen, J.3    Santuray, R.4
  • 15
    • 0028066753 scopus 로고
    • Use of on-line gas analysis to monitor recombinant mammalian cell cultures
    • Lovrecz, G., Gray, P., Use of on-line gas analysis to monitor recombinant mammalian cell cultures. Cytotechnology 1994, 143, 167-175.
    • (1994) Cytotechnology , vol.143 , pp. 167-175
    • Lovrecz, G.1    Gray, P.2
  • 16
    • 0028008437 scopus 로고
    • Mass spectrometry: A tool for on-line monitoring of animal cell cultures
    • Behrendt, U., Koch, S., Gooch, D. D., Steegmans, U., Comer, M. J., Mass spectrometry: A tool for on-line monitoring of animal cell cultures. Cytotechnology 1994, 143, 157-165.
    • (1994) Cytotechnology , vol.143 , pp. 157-165
    • Behrendt, U.1    Koch, S.2    Gooch, D.D.3    Steegmans, U.4    Comer, M.J.5
  • 17
    • 77955984590 scopus 로고    scopus 로고
    • Discrimination of cancerous and non-cancerous cell lines by headspace-analysis with PTR-MS
    • Brunner, C., Szymczak, W., Hollriegl, V., Mortl, S. et al., Discrimination of cancerous and non-cancerous cell lines by headspace-analysis with PTR-MS. Anal. Bioanal. Chem. 2010, 3976, 2315-2324.
    • (2010) Anal. Bioanal. Chem. , vol.3976 , pp. 2315-2324
    • Brunner, C.1    Szymczak, W.2    Hollriegl, V.3    Mortl, S.4
  • 18
    • 84898546926 scopus 로고    scopus 로고
    • Advanced online monitoring of cell culture off-gas using proton transfer reaction mass spectrometry
    • Schmidberger, T., Gutmann, R., Bayer, K., Kronthaler, J., Huber, R., Advanced online monitoring of cell culture off-gas using proton transfer reaction mass spectrometry, Biotechnol. Prog. 2014, 302, 496-504.
    • (2014) Biotechnol. Prog , vol.302 , pp. 496-504
    • Schmidberger, T.1    Gutmann, R.2    Bayer, K.3    Kronthaler, J.4    Huber, R.5
  • 19
    • 13144251172 scopus 로고    scopus 로고
    • Chemical sensors for electronic nose systems
    • James, D., Scott, S. M., Ali, Z., O'Hare, W. T., Chemical sensors for electronic nose systems. Microchim. Acta 2005, 1491-1492, 1-17.
    • (2005) Microchim. Acta , vol.1491-1492 , pp. 1-17
    • James, D.1    Scott, S.M.2    Ali, Z.3    O'Hare, W.T.4
  • 20
    • 0033991285 scopus 로고    scopus 로고
    • Monitoring cellular state transitions in a production-scale CHO-cell process using an electronic nose
    • Bachinger, T., Riese, U., Eriksson, R., Mandenius, C. F., Monitoring cellular state transitions in a production-scale CHO-cell process using an electronic nose. J. Biotechnol. 2000, 761, 61-71.
    • (2000) J. Biotechnol , vol.761 , pp. 61-71
    • Bachinger, T.1    Riese, U.2    Eriksson, R.3    Mandenius, C.F.4
  • 21
    • 28644439526 scopus 로고    scopus 로고
    • On-line detection of microbial contaminations in animal cell reactor cultures using an electronic nose device
    • Kreij, K., Mandenius, C. F., Clemente, J. J., Cunha, A. E. et al., On-line detection of microbial contaminations in animal cell reactor cultures using an electronic nose device. Cytotechnology 2005, 48, 41-58.
    • (2005) Cytotechnology , vol.48 , pp. 41-58
    • Kreij, K.1    Mandenius, C.F.2    Clemente, J.J.3    Cunha, A.E.4
  • 23
    • 77955476660 scopus 로고    scopus 로고
    • Optical device for parallel online measurement of dissolved oxygen and pH in shake flask cultures
    • Schneider, K., Schutz, V., John, G. T., Heinzle, E., Optical device for parallel online measurement of dissolved oxygen and pH in shake flask cultures. Bioprocess Biosyst. Eng. 2010, 335, 541-547.
    • (2010) Bioprocess Biosyst. Eng , vol.335 , pp. 541-547
    • Schneider, K.1    Schutz, V.2    John, G.T.3    Heinzle, E.4
  • 24
    • 0034320861 scopus 로고    scopus 로고
    • Setup of a fiber optical oxygen multisensor-system and its applications in biotechnology
    • Kohls, O., Scheper, T., Setup of a fiber optical oxygen multisensor-system and its applications in biotechnology. Sensors Actuators B Chem. 2000, 70, 121-130.
    • (2000) Sensors Actuators B Chem. , vol.70 , pp. 121-130
    • Kohls, O.1    Scheper, T.2
  • 25
    • 0037341103 scopus 로고    scopus 로고
    • Characterization and application of an optical sensor for quantification of dissolved O2 in shake-flasks
    • Wittmann, C., Kim, H. M., John, G., Heinzle, E., Characterization and application of an optical sensor for quantification of dissolved O2 in shake-flasks. Biotechnol. Lett. 2003, 255, 377-380.
    • (2003) Biotechnol. Lett , vol.255 , pp. 377-380
    • Wittmann, C.1    Kim, H.M.2    John, G.3    Heinzle, E.4
  • 26
    • 9544238230 scopus 로고    scopus 로고
    • Noninvasive oxygen measurements and mass transfer considerations in tissue culture flasks
    • Randers-Eichhorn, L., Bartlett, R. A., Frey, D. D., Rao, G., Noninvasive oxygen measurements and mass transfer considerations in tissue culture flasks. Biotechnol. Bioeng. 1996, 514, 466-478.
    • (1996) Biotechnol. Bioeng , vol.514 , pp. 466-478
    • Randers-Eichhorn, L.1    Bartlett, R.A.2    Frey, D.D.3    Rao, G.4
  • 27
    • 79958058759 scopus 로고    scopus 로고
    • Evaluation of phototoxicity of dendritic porphyrin-based phosphorescent oxygen probes: an in vitro study
    • Ceroni, P., Lebedev, A. Y., Marchi, E., Yuan, M. et al., Evaluation of phototoxicity of dendritic porphyrin-based phosphorescent oxygen probes: an in vitro study. Photochem. Photobiol. Sci. 2011, 106, 1056-1065.
    • (2011) Photochem. Photobiol. Sci , vol.106 , pp. 1056-1065
    • Ceroni, P.1    Lebedev, A.Y.2    Marchi, E.3    Yuan, M.4
  • 28
    • 84870799551 scopus 로고    scopus 로고
    • Indicators for optical oxygen sensors
    • Quaranta, M., Borisov, S. M., Klimant, I., Indicators for optical oxygen sensors. Bioanal. Rev. 2012, 4, 115-157.
    • (2012) Bioanal. Rev , vol.4 , pp. 115-157
    • Quaranta, M.1    Borisov, S.M.2    Klimant, I.3
  • 29
    • 84893720251 scopus 로고    scopus 로고
    • A completely noninvasive method of dissolved oxygen monitoring in disposable small-scale cell culture vessels based on diffusion through permeable vessel walls
    • Gupta, P. A., Ge, X., Kostov, Y., Rao, G., A completely noninvasive method of dissolved oxygen monitoring in disposable small-scale cell culture vessels based on diffusion through permeable vessel walls. Biotechnol. Prog. 2014, 301, 172-177.
    • (2014) Biotechnol. Prog , vol.301 , pp. 172-177
    • Gupta, P.A.1    Ge, X.2    Kostov, Y.3    Rao, G.4
  • 32
    • 0029038879 scopus 로고
    • A fiberoptic carbon-dioxide sensor for fermentation monitoring
    • Uttamlal, M., Walt, D. R., A fiberoptic carbon-dioxide sensor for fermentation monitoring. Bio-Technology 1995, 136, 597-601.
    • (1995) Bio-Technology , vol.136 , pp. 597-601
    • Uttamlal, M.1    Walt, D.R.2
  • 33
    • 84862171398 scopus 로고    scopus 로고
    • Real-time monitoring of shake flask fermentation and off gas using triple disposable noninvasive optical sensors
    • Ge, X., Rao, G., Real-time monitoring of shake flask fermentation and off gas using triple disposable noninvasive optical sensors. Biotechnol. Prog. 2012, 283, 872-877.
    • (2012) Biotechnol. Prog , vol.283 , pp. 872-877
    • Ge, X.1    Rao, G.2
  • 34
    • 0036753412 scopus 로고    scopus 로고
    • Dual excitation ratiometric fluorescent pH sensor for noninvasive bioprocess monitoring: development and application
    • Kermis, H. R., Kostov, Y., Harms, P., Rao, G., Dual excitation ratiometric fluorescent pH sensor for noninvasive bioprocess monitoring: development and application. Biotechnol. Prog. 2002, 185, 1047-1453.
    • (2002) Biotechnol. Prog. , vol.185 , pp. 1047-1453
    • Kermis, H.R.1    Kostov, Y.2    Harms, P.3    Rao, G.4
  • 35
    • 62249114097 scopus 로고    scopus 로고
    • Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring
    • Badugu, R., Kostov, Y., Rao, G., Tolosa, L., Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring. Biotechnol. Prog. 2008, 246, 1393-1401.
    • (2008) Biotechnol. Prog , vol.246 , pp. 1393-1401
    • Badugu, R.1    Kostov, Y.2    Rao, G.3    Tolosa, L.4
  • 36
    • 20444399524 scopus 로고    scopus 로고
    • Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications
    • Reich, G., Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. Adv. Drug Deliv. Rev. 2005, 578, 1109-1143.
    • (2005) Adv. Drug Deliv. Rev. , vol.578 , pp. 1109-1143
    • Reich, G.1
  • 37
    • 80052185259 scopus 로고    scopus 로고
    • Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes
    • DeBeer, T., Burggraeve, A., Fonteyne, M., Saerens, L. et al., Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes. Int. J. Pharm. 2011, 417, 32-47.
    • (2011) Int. J. Pharm , vol.417 , pp. 32-47
    • De Beer, T.1    Burggraeve, A.2    Fonteyne, M.3    Saerens, L.4
  • 38
    • 14544282675 scopus 로고    scopus 로고
    • Pharmaceutical industry embraces NIR technology
    • Forcinio, H., Pharmaceutical industry embraces NIR technology. Spectroscopy 2003, 189, 16.
    • (2003) Spectroscopy , vol.189 , pp. 16
    • Forcinio, H.1
  • 39
    • 0032970782 scopus 로고    scopus 로고
    • In situ monitoring of an Escherichia coli fermentation using a diamond composition ATR probe and mid-infrared spectroscopy
    • Doak, D. L., Phillips, J. A., In situ monitoring of an Escherichia coli fermentation using a diamond composition ATR probe and mid-infrared spectroscopy. Biotechnol. Prog. 1999, 15, 529-529.
    • (1999) Biotechnol. Prog , vol.15 , pp. 529-529
    • Doak, D.L.1    Phillips, J.A.2
  • 40
    • 84883555277 scopus 로고    scopus 로고
    • Performance monitoring of a mammalian cell based bioprocess using Raman spectroscopy
    • Li, B., Ray, B. H., Leister, K. J., Ryder, A. G., Performance monitoring of a mammalian cell based bioprocess using Raman spectroscopy. Anal. Chim. Acta. 2013, 796, 84-91.
    • (2013) Anal. Chim. Acta. , vol.796 , pp. 84-91
    • Li, B.1    Ray, B.H.2    Leister, K.J.3    Ryder, A.G.4
  • 41
    • 84860488719 scopus 로고    scopus 로고
    • On-line measurement of the substrate concentrations in Pichia pastoris fermentations using FT-IR/ATR
    • Dahlbacka, J., Weegar, J., vonWeymarn, N., Fagervik, K., On-line measurement of the substrate concentrations in Pichia pastoris fermentations using FT-IR/ATR. Biotechnol. Lett. 2012, 346, 1009-1017.
    • (2012) Biotechnol. Lett. , vol.346 , pp. 1009-1017
    • Dahlbacka, J.1    Weegar, J.2    von Weymarn, N.3    Fagervik, K.4
  • 42
    • 84870376049 scopus 로고    scopus 로고
    • Sugar uptake analysis of suspension Arabidopsis, tobacco, and rice cells in various media using an FT-IR/ATR method
    • Suehara, K., Kameoka, T., Hashimoto, A., Sugar uptake analysis of suspension Arabidopsis, tobacco, and rice cells in various media using an FT-IR/ATR method. Bioprocess Biosyst. Eng. 2012, 358, 1259-1268.
    • (2012) Bioprocess Biosyst. Eng. , vol.358 , pp. 1259-1268
    • Suehara, K.1    Kameoka, T.2    Hashimoto, A.3
  • 43
    • 84881542735 scopus 로고    scopus 로고
    • FT-IR/ATR univariate and multivariate calibration models for in situ monitoring of sugars in complex microalgal culture media
    • Girard, J. M., Deschenes, J. S., Tremblay, R., Gagnon, J., FT-IR/ATR univariate and multivariate calibration models for in situ monitoring of sugars in complex microalgal culture media. Bioresour. Technol. 2013, 144, 664-668.
    • (2013) Bioresour. Technol , vol.144 , pp. 664-668
    • Girard, J.M.1    Deschenes, J.S.2    Tremblay, R.3    Gagnon, J.4
  • 44
    • 84923167613 scopus 로고    scopus 로고
    • Ultrasound-enhanced attenuated total reflection mid-infrared spectroscopy in-line probe: acquisition of cell spectra in a bioreactor
    • Koch, C., Brandstetter, M., Wechselberger, P., Lorantfy, B. et al., Ultrasound-enhanced attenuated total reflection mid-infrared spectroscopy in-line probe: acquisition of cell spectra in a bioreactor. Anal. Chem. 2015, 87, 2314-2320.
    • (2015) Anal. Chem. , vol.87 , pp. 2314-2320
    • Koch, C.1    Brandstetter, M.2    Wechselberger, P.3    Lorantfy, B.4
  • 45
    • 84922982393 scopus 로고    scopus 로고
    • Advanced near-infrared monitor for stable real-time measurement and control of Pichia pastoris bioprocesses
    • Goldfeld, M., Christensen, J., Pollard, D., Gibson, E. R. et al., Advanced near-infrared monitor for stable real-time measurement and control of Pichia pastoris bioprocesses. Biotechnol. Progress. 2014, 303, 749-759.
    • (2014) Biotechnol. Progress , vol.303 , pp. 749-759
    • Goldfeld, M.1    Christensen, J.2    Pollard, D.3    Gibson, E.R.4
  • 46
    • 84893383641 scopus 로고    scopus 로고
    • On-line near infrared bioreactor monitoring of cell density and concentrations of glucose and lactate during insect cell cultivation
    • Qiu, J., Arnold, M. A., Murhammer, D. W., On-line near infrared bioreactor monitoring of cell density and concentrations of glucose and lactate during insect cell cultivation. J. Biotechnol. 2014, 173, 106-111.
    • (2014) J. Biotechnol , vol.173 , pp. 106-111
    • Qiu, J.1    Arnold, M.A.2    Murhammer, D.W.3
  • 47
    • 0043195339 scopus 로고    scopus 로고
    • In-situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
    • Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., McNeil, B., In-situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation. Biotechnol. Bioeng. 2003, 841, 13-19.
    • (2003) Biotechnol. Bioeng , vol.841 , pp. 13-19
    • Arnold, S.A.1    Crowley, J.2    Woods, N.3    Harvey, L.M.4    McNeil, B.5
  • 48
    • 34047124391 scopus 로고    scopus 로고
    • Multiplexing fibre optic near infrared (NIR) spectroscopy as an emerging technology to monitor industrial bioprocesses
    • Roychoudhury, P., O'Kennedy, R., McNeil, B., Harvey, L. M., Multiplexing fibre optic near infrared (NIR) spectroscopy as an emerging technology to monitor industrial bioprocesses. Anal. Chim. Acta. 2007, 5901, 110-117.
    • (2007) Anal. Chim. Acta. , vol.5901 , pp. 110-117
    • Roychoudhury, P.1    O'Kennedy, R.2    McNeil, B.3    Harvey, L.M.4
  • 49
    • 84876268622 scopus 로고    scopus 로고
    • Chemometrics and in-line near infrared spectroscopic monitoring of a biopharmaceutical Chinese hamster ovary cell culture: prediction of multiple cultivation variables
    • Clavaud, M., Roggo, Y., VonDaeniken, R., Liebler, A., Schwabe, J. O., Chemometrics and in-line near infrared spectroscopic monitoring of a biopharmaceutical Chinese hamster ovary cell culture: prediction of multiple cultivation variables. Talanta 2013, 111, 28-38.
    • (2013) Talanta , vol.111 , pp. 28-38
    • Clavaud, M.1    Roggo, Y.2    Von Daeniken, R.3    Liebler, A.4    Schwabe, J.O.5
  • 50
    • 84897029909 scopus 로고    scopus 로고
    • Semisynthetic model calibration for monitoring glucose in mammalian cell culture with in situ near infrared spectroscopy
    • Milligan, M., Lewin-Koh, N., Coleman, D., Arroyo, A., Saucedo, V., Semisynthetic model calibration for monitoring glucose in mammalian cell culture with in situ near infrared spectroscopy. Biotechnol. Bioeng. 2014, 1115, 896-903.
    • (2014) Biotechnol. Bioeng , vol.1115 , pp. 896-903
    • Milligan, M.1    Lewin-Koh, N.2    Coleman, D.3    Arroyo, A.4    Saucedo, V.5
  • 51
    • 0037137921 scopus 로고    scopus 로고
    • Real-time in situ monitoring of freely suspended and immobilized cell cultures based on mid-infrared spectroscopic measurements
    • Rhiel, M., Ducommun, P., Bolzonella, I., Marison, I., vonStockar, U., Real-time in situ monitoring of freely suspended and immobilized cell cultures based on mid-infrared spectroscopic measurements. Biotechnol. Bioeng. 2002, 772, 174-185.
    • (2002) Biotechnol. Bioeng , vol.772 , pp. 174-185
    • Rhiel, M.1    Ducommun, P.2    Bolzonella, I.3    Marison, I.4    von Stockar, U.5
  • 52
    • 79953152705 scopus 로고    scopus 로고
    • Real time monitoring of multiple parameters in mammalian cell culture bioreactors using an in-line Raman spectroscopy probe
    • Abu-Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C. et al., Real time monitoring of multiple parameters in mammalian cell culture bioreactors using an in-line Raman spectroscopy probe. Biotechnol. Bioeng. 2011, 1085, 1215-1221.
    • (2011) Biotechnol. Bioeng , vol.1085 , pp. 1215-1221
    • Abu-Absi, N.R.1    Kenty, B.M.2    Cuellar, M.E.3    Borys, M.C.4
  • 53
    • 84867405067 scopus 로고    scopus 로고
    • In situ Raman spectroscopy for simultaneous monitoring of multiple process parameters in mammalian cell culture bioreactors
    • Whelan, J., Craven, S., Glennon, B., In situ Raman spectroscopy for simultaneous monitoring of multiple process parameters in mammalian cell culture bioreactors. Biotechnol. Prog. 2012, 285, 1355-1362.
    • (2012) Biotechnol. Prog. , vol.285 , pp. 1355-1362
    • Whelan, J.1    Craven, S.2    Glennon, B.3
  • 54
    • 84928173379 scopus 로고    scopus 로고
    • Cross-scale predictive modeling of CHO cell culture growth and metabolites using Raman spectroscopy and multivariate analysis
    • Berry, B., Moretto, J., Matthews, T., Smelko, J., Wiltberger, K., Cross-scale predictive modeling of CHO cell culture growth and metabolites using Raman spectroscopy and multivariate analysis. Biotechnol. Prog. 2014. DOI: 10.1002/btpr.2035
    • (2014) Biotechnol. Prog
    • Berry, B.1    Moretto, J.2    Matthews, T.3    Smelko, J.4    Wiltberger, K.5
  • 56
    • 0028454939 scopus 로고
    • On-line characterization of a hybridoma cell culture process
    • Zhou, W., Hu, W.-S., On-line characterization of a hybridoma cell culture process. Biotechnol. Bioeng. 1994, 44, 170-177.
    • (1994) Biotechnol. Bioeng. , vol.44 , pp. 170-177
    • Zhou, W.1    Hu, W.-S.2
  • 57
    • 79955590003 scopus 로고    scopus 로고
    • Process control in cell culture technology using dielectric spectroscopy
    • Justice, C., Brix, A., Freimark, D., Kraume, M. et al., Process control in cell culture technology using dielectric spectroscopy. Biotechnol. Adv. 2011, 294, 391-401.
    • (2011) Biotechnol. Adv. , vol.294 , pp. 391-401
    • Justice, C.1    Brix, A.2    Freimark, D.3    Kraume, M.4
  • 58
    • 0345369598 scopus 로고    scopus 로고
    • Dielectric spectroscopy in the cultivation of suspended and immobilized hybridoma cells
    • Noll, T., Biselli, M., Dielectric spectroscopy in the cultivation of suspended and immobilized hybridoma cells. J. Biotechnol. 1998, 633, 187-198.
    • (1998) J. Biotechnol , vol.633 , pp. 187-198
    • Noll, T.1    Biselli, M.2
  • 59
    • 0038731394 scopus 로고    scopus 로고
    • On-line biomass monitoring of CHO perfusion culture with scanning dielectric spectroscopy
    • Cannizzaro, C., Gugerli, R., Marison, I., vonStockar, U., On-line biomass monitoring of CHO perfusion culture with scanning dielectric spectroscopy. Biotechnol. Bioeng. 2003, 845, 597-610.
    • (2003) Biotechnol. Bioeng. , vol.845 , pp. 597-610
    • Cannizzaro, C.1    Gugerli, R.2    Marison, I.3    von Stockar, U.4
  • 60
    • 33847038002 scopus 로고    scopus 로고
    • Use of an in-situ microscope for on-line observation of animal cell cultures
    • Frerichs, J. G., Joeris, K., Konstantinov, K., Scheper, T., Use of an in-situ microscope for on-line observation of animal cell cultures. Chemie Ingenieur Technik. 2002, 7411, 1629-1633.
    • (2002) Chemie Ingenieur Technik. , vol.7411 , pp. 1629-1633
    • Frerichs, J.G.1    Joeris, K.2    Konstantinov, K.3    Scheper, T.4
  • 61
    • 0036425993 scopus 로고    scopus 로고
    • In-situ microscopy: online process monitoring of mammalian cell cultures
    • Joeris, K., Frerichs, J. G., Konstantinov, K., Scheper, T., In-situ microscopy: online process monitoring of mammalian cell cultures. Cytotechnology 2002, 38, 129-134.
    • (2002) Cytotechnology , vol.38 , pp. 129-134
    • Joeris, K.1    Frerichs, J.G.2    Konstantinov, K.3    Scheper, T.4
  • 62
    • 33847159854 scopus 로고    scopus 로고
    • Preliminary study towards the use of in-situ microscopy for the online analysis of microcarrier cultivations
    • Anton, F., Burzlaff, A., Kasper, C., Bruckerhoff, T., Scheper, T., Preliminary study towards the use of in-situ microscopy for the online analysis of microcarrier cultivations. Eng. Life Sci. 2007, 71, 91-96.
    • (2007) Eng. Life Sci. , vol.71 , pp. 91-96
    • Anton, F.1    Burzlaff, A.2    Kasper, C.3    Bruckerhoff, T.4    Scheper, T.5
  • 63
    • 0029636675 scopus 로고
    • In-situ microscopy for online characterization of cell-populations in bioreactors, including cell-concentration measurements by depth from focus
    • Suhr, H., Wehnert, G., Schneider, K., Bittner, C. et al., In-situ microscopy for online characterization of cell-populations in bioreactors, including cell-concentration measurements by depth from focus. Biotechnol. Bioeng. 1995, 471, 106-116.
    • (1995) Biotechnol. Bioeng. , vol.471 , pp. 106-116
    • Suhr, H.1    Wehnert, G.2    Schneider, K.3    Bittner, C.4
  • 64
    • 0037023664 scopus 로고    scopus 로고
    • Inline characterization of cell concentration and cell volume in agitated bioreactors using in situ microscopy: application to volume variation induced by osmotic stress
    • Camisard, V., Brienne, J., Baussart, H., Hammann, J., Suhr, H., Inline characterization of cell concentration and cell volume in agitated bioreactors using in situ microscopy: application to volume variation induced by osmotic stress. Biotechnol. Bioeng. 2002, 781, 73-80.
    • (2002) Biotechnol. Bioeng , vol.781 , pp. 73-80
    • Camisard, V.1    Brienne, J.2    Baussart, H.3    Hammann, J.4    Suhr, H.5
  • 65
    • 3042837382 scopus 로고    scopus 로고
    • Real time in situ microscopy for animal cell-concentration monitoring during high density culture in bioreactor
    • Guez, J. S., Cassar, J. P., Wartelle, F., Dhulster, P., Suhr, H., Real time in situ microscopy for animal cell-concentration monitoring during high density culture in bioreactor. J. Biotechnol. 2004, 1113, 335-343.
    • (2004) J. Biotechnol , vol.1113 , pp. 335-343
    • Guez, J.S.1    Cassar, J.P.2    Wartelle, F.3    Dhulster, P.4    Suhr, H.5
  • 66
    • 37549064018 scopus 로고    scopus 로고
    • Online monitoring of microcarrier based fibroblast cultivations with in situ microscopy
    • Rudolph, G., Lindner, P., Gierse, A., Bluma, A. et al., Online monitoring of microcarrier based fibroblast cultivations with in situ microscopy. Biotechnol. Bioeng. 2008, 991, 136-145.
    • (2008) Biotechnol. Bioeng , vol.991 , pp. 136-145
    • Rudolph, G.1    Lindner, P.2    Gierse, A.3    Bluma, A.4
  • 67
    • 0033525428 scopus 로고    scopus 로고
    • A flow injection flow cytometry system for on-line monitoring of bioreactors
    • Zhao, R., Natarajan, A., Srienc, F., A flow injection flow cytometry system for on-line monitoring of bioreactors. Biotechnol. Bioeng. 1999, 62, 609-617.
    • (1999) Biotechnol. Bioeng , vol.62 , pp. 609-617
    • Zhao, R.1    Natarajan, A.2    Srienc, F.3
  • 68
    • 79960427553 scopus 로고    scopus 로고
    • Real-time on-line flow cytometry for bioprocess monitoring
    • Broger, T., Odermatt, R. P., Huber, P., Sonnleitner, B., Real-time on-line flow cytometry for bioprocess monitoring. J. Biotechnol. 2011, 1544, 240-247.
    • (2011) J. Biotechnol , vol.1544 , pp. 240-247
    • Broger, T.1    Odermatt, R.P.2    Huber, P.3    Sonnleitner, B.4
  • 69
    • 43849085943 scopus 로고    scopus 로고
    • Mammalian cell culture scale-up and fed-batch control using automated flow cytometry
    • Sitton, G., Srienc, F., Mammalian cell culture scale-up and fed-batch control using automated flow cytometry. J. Biotechnol. 2008, 1352, 174-180.
    • (2008) J. Biotechnol , vol.1352 , pp. 174-180
    • Sitton, G.1    Srienc, F.2
  • 70
    • 84921723571 scopus 로고    scopus 로고
    • Online flow cytometry for monitoring apoptosis in mammalian cell cultures as an application for process analytical technology
    • Kuystermans, D., Avesh, M., Al-Rubeai, M., Online flow cytometry for monitoring apoptosis in mammalian cell cultures as an application for process analytical technology. Cytotechnology 2014. DOI: 10.1007/s10616-014-9791-3
    • (2014) Cytotechnology
    • Kuystermans, D.1    Avesh, M.2    Al-Rubeai, M.3
  • 71
    • 76849117155 scopus 로고    scopus 로고
    • Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer
    • Derfus, G. E., Abramzon, D., Tung, M., Chang, D. et al., Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer. Biotechnol. Prog. 2010, 261, 284-292.
    • (2010) Biotechnol. Prog. , vol.261 , pp. 284-292
    • Derfus, G.E.1    Abramzon, D.2    Tung, M.3    Chang, D.4
  • 72
    • 0037022981 scopus 로고    scopus 로고
    • Chemometric evaluation of on-line high-pressure liquid chromatography in mammalian cell cultures: Analysis of amino acids and glucose
    • Larson, T. M., Gawlitzek, M., Evans, H., Albers, U., Cacia, J., Chemometric evaluation of on-line high-pressure liquid chromatography in mammalian cell cultures: Analysis of amino acids and glucose. Biotechnol. Bioeng. 2002, 775, 553-563.
    • (2002) Biotechnol. Bioeng , vol.775 , pp. 553-563
    • Larson, T.M.1    Gawlitzek, M.2    Evans, H.3    Albers, U.4    Cacia, J.5
  • 74
    • 0028765274 scopus 로고
    • Growth characterization in fed-batch culture of hybridoma cells with control of glucose and glutamine concentration
    • Kurokawa, H., Park, Y. S., Iijima, S., Kobayashi, T., Growth characterization in fed-batch culture of hybridoma cells with control of glucose and glutamine concentration. Biotechnol. Bioeng. 1994, 44, 95-103.
    • (1994) Biotechnol. Bioeng , vol.44 , pp. 95-103
    • Kurokawa, H.1    Park, Y.S.2    Iijima, S.3    Kobayashi, T.4
  • 75
    • 77956886210 scopus 로고    scopus 로고
    • A high-throughput method for quantification of glycoprotein sialylation
    • Markely, L. R., Ong, B. T., Hoi, K. M., Teo, G. et al., A high-throughput method for quantification of glycoprotein sialylation. Anal. Biochem. 2010, 407, 128-133.
    • (2010) Anal. Biochem. , vol.407 , pp. 128-133
    • Markely, L.R.1    Ong, B.T.2    Hoi, K.M.3    Teo, G.4
  • 76
    • 84862126576 scopus 로고    scopus 로고
    • Rapid evaluation for heterogeneities in monoclonal antibodies by liquid chromatography/mass spectrometry with a column-switching system
    • Kuribayashi, R., Hashii, N., Harazono, A., Kawasaki, N., Rapid evaluation for heterogeneities in monoclonal antibodies by liquid chromatography/mass spectrometry with a column-switching system. J. Pharm. Biomed. Anal. 2012, 6, 1-9.
    • (2012) J. Pharm. Biomed. Anal. , vol.6 , pp. 1-9
    • Kuribayashi, R.1    Hashii, N.2    Harazono, A.3    Kawasaki, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.