-
1
-
-
0033223147
-
A 10-year longitudinal study of fixed prosthodontics: Clinical characteristics and outcome of single-unit metal-ceramic crowns
-
T.R. Walton A 10-year longitudinal study of fixed prosthodontics: clinical characteristics and outcome of single-unit metal-ceramic crowns Int J Prosthodont 12 1999 519 526
-
(1999)
Int J Prosthodont
, vol.12
, pp. 519-526
-
-
Walton, T.R.1
-
2
-
-
0035749346
-
The metal-free practice: Myth? Reality? Desirable goal?
-
F.M. Spear The metal-free practice: myth? Reality? Desirable goal? J Esthet Restor Dent 13 2001 59 67
-
(2001)
J Esthet Restor Dent
, vol.13
, pp. 59-67
-
-
Spear, F.M.1
-
3
-
-
0036633168
-
Relative translucency of six all-ceramic systems. Part 1: Core materials
-
M.J. Heffernan, S.A. Aquilino, A.M. Diaz-Arnold, D.R. Haselton, C.M. Stanford, and M.A. Vargas Relative translucency of six all-ceramic systems. Part 1: core materials J Prosthet Dent 88 2002 4 9
-
(2002)
J Prosthet Dent
, vol.88
, pp. 4-9
-
-
Heffernan, M.J.1
Aquilino, S.A.2
Diaz-Arnold, A.M.3
Haselton, D.R.4
Stanford, C.M.5
Vargas, M.A.6
-
4
-
-
33746913496
-
Metal-ceramic failure in noble metal crowns: 7-year results of a prospective clinical trial in private practices
-
B. Reitemeier, K. Hänsel, C. Kastner, and M.H. Walter Metal-ceramic failure in noble metal crowns: 7-year results of a prospective clinical trial in private practices Int J Prosthodont 19 2006 397 399
-
(2006)
Int J Prosthodont
, vol.19
, pp. 397-399
-
-
Reitemeier, B.1
Hänsel, K.2
Kastner, C.3
Walter, M.H.4
-
5
-
-
34250612616
-
A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns
-
B.E. Pjetursson, I. Sailer, M. Zwahlen, and C.H. Hämmerle A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns Clin Oral Implants Res 18 Suppl. 3 2007 73 85
-
(2007)
Clin Oral Implants Res
, vol.18
, Issue.SUPPL. 3
, pp. 73-85
-
-
Pjetursson, B.E.1
Sailer, I.2
Zwahlen, M.3
Hämmerle, C.H.4
-
6
-
-
34250665803
-
A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses
-
I. Sailer, B.E. Pjetursson, M. Zwahlen, and C.H. Hämmerle A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses Clin Oral Implants Res 18 Suppl. 3 2007 86 96
-
(2007)
Clin Oral Implants Res
, vol.18
, Issue.SUPPL. 3
, pp. 86-96
-
-
Sailer, I.1
Pjetursson, B.E.2
Zwahlen, M.3
Hämmerle, C.H.4
-
7
-
-
43449084359
-
Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
-
F. Wettstein, I. Sailer, M. Roos, and C.H. Hämmerle Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures Eur J Oral Sci 116 2008 272 279
-
(2008)
Eur J Oral Sci
, vol.116
, pp. 272-279
-
-
Wettstein, F.1
Sailer, I.2
Roos, M.3
Hämmerle, C.H.4
-
9
-
-
52449118551
-
Factors essential for successful all-ceramic restorations
-
T.E. Donovan Factors essential for successful all-ceramic restorations J Am Dent Assoc 139 Suppl. 2008 14S 18S
-
(2008)
J Am Dent Assoc
, vol.139
, Issue.SUPPL.
-
-
Donovan, T.E.1
-
10
-
-
36148962932
-
Current ceramic materials and systems with clinical recommendations: A systematic review
-
H.J. Conrad, W.J. Seong, and I.J. Pesun Current ceramic materials and systems with clinical recommendations: a systematic review J Prosthet Dent 98 2007 389 404
-
(2007)
J Prosthet Dent
, vol.98
, pp. 389-404
-
-
Conrad, H.J.1
Seong, W.J.2
Pesun, I.J.3
-
11
-
-
0000653434
-
The reinforcement of dental porcelain with ceramic oxides
-
L.W. McLean, and T.H. Hughes The reinforcement of dental porcelain with ceramic oxides Br Dent J 119 1965 251 267
-
(1965)
Br Dent J
, vol.119
, pp. 251-267
-
-
McLean, L.W.1
Hughes, T.H.2
-
12
-
-
0032608003
-
Survival of Dicor glass-ceramic dental restorations over 14 years: Part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age
-
K.A. Malament, and S.S. Socransky Survival of Dicor glass-ceramic dental restorations over 14 years: part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age J Prosthet Dent 81 1999 23 32
-
(1999)
J Prosthet Dent
, vol.81
, pp. 23-32
-
-
Malament, K.A.1
Socransky, S.S.2
-
13
-
-
0032620677
-
Ceramic restorations for posterior teeth: Guidelines for the clinician
-
A.V. Ritter, and L.N. Baratieri Ceramic restorations for posterior teeth: guidelines for the clinician J Esthet Dent 11 1999 72 86
-
(1999)
J Esthet Dent
, vol.11
, pp. 72-86
-
-
Ritter, A.V.1
Baratieri, L.N.2
-
14
-
-
0034264517
-
Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics
-
J. Tinschert, D. Zwez, R. Marx, and K.J. Anusavice Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics J Dent 28 2000 529 535
-
(2000)
J Dent
, vol.28
, pp. 529-535
-
-
Tinschert, J.1
Zwez, D.2
Marx, R.3
Anusavice, K.J.4
-
15
-
-
0035240653
-
Flexural strength optimisation of a leucite reinforced glass ceramic
-
M.J. Cattell, T.C. Chadwick, J.C. Knowles, R.L. Clarke, and E. Lynch Flexural strength optimisation of a leucite reinforced glass ceramic Dent Mater 17 2001 21 33
-
(2001)
Dent Mater
, vol.17
, pp. 21-33
-
-
Cattell, M.J.1
Chadwick, T.C.2
Knowles, J.C.3
Clarke, R.L.4
Lynch, E.5
-
16
-
-
9944229063
-
Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
-
A.J. Raigrodski Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature J Prosthet Dent 92 2004 557 562
-
(2004)
J Prosthet Dent
, vol.92
, pp. 557-562
-
-
Raigrodski, A.J.1
-
17
-
-
34547603573
-
Flexural strength and fracture toughness of dental core ceramics
-
H. Yilmaz, C. Aydin, and B.E. Gul Flexural strength and fracture toughness of dental core ceramics J Prosthet Dent 98 2007 120 128
-
(2007)
J Prosthet Dent
, vol.98
, pp. 120-128
-
-
Yilmaz, H.1
Aydin, C.2
Gul, B.E.3
-
18
-
-
0036652611
-
An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: A retrospective study
-
M. Fradeani, and M. Redemagni An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study Quintessence Int 33 2002 503 510
-
(2002)
Quintessence Int
, vol.33
, pp. 503-510
-
-
Fradeani, M.1
Redemagni, M.2
-
20
-
-
13444301265
-
Porcelain laminate veneers: 6- to 12-year clinical evaluation - A retrospective study
-
M. Fradeani, M. Redemagni, and M. Corrado Porcelain laminate veneers: 6- to 12-year clinical evaluation - a retrospective study Int J Periodontics Restorative Dent 25 2005 9 17
-
(2005)
Int J Periodontics Restorative Dent
, vol.25
, pp. 9-17
-
-
Fradeani, M.1
Redemagni, M.2
Corrado, M.3
-
21
-
-
34547639165
-
An up to 16-year prospective study of 304 porcelain veneers
-
D. Layton, and T. Walton An up to 16-year prospective study of 304 porcelain veneers Int J Prosthodont 20 2007 389 396
-
(2007)
Int J Prosthodont
, vol.20
, pp. 389-396
-
-
Layton, D.1
Walton, T.2
-
22
-
-
52049101566
-
Translucency and biaxial flexural strength of four ceramic core materials
-
Y.M. Chen, R.J. Smales, K.H. Yip, and W.J. Sung Translucency and biaxial flexural strength of four ceramic core materials Dent Mater 24 2008 1506 1511
-
(2008)
Dent Mater
, vol.24
, pp. 1506-1511
-
-
Chen, Y.M.1
Smales, R.J.2
Yip, K.H.3
Sung, W.J.4
-
23
-
-
33646364586
-
Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation
-
C.F. Stappert, W. Att, T. Gerds, and J.R. Strub Fracture resistance of different partial-coverage ceramic molar restorations: an in vitro investigation J Am Dent Assoc 137 2006 514 522
-
(2006)
J Am Dent Assoc
, vol.137
, pp. 514-522
-
-
Stappert, C.F.1
Att, W.2
Gerds, T.3
Strub, J.R.4
-
24
-
-
34047214549
-
A short-term clinical evaluation of IPS Empress 2 crowns
-
S. Toksavul, and M. Toman A short-term clinical evaluation of IPS Empress 2 crowns Int J Prosthodont 20 2007 168 172
-
(2007)
Int J Prosthodont
, vol.20
, pp. 168-172
-
-
Toksavul, S.1
Toman, M.2
-
25
-
-
33645309086
-
Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: Results of a 5-year prospective clinical study
-
P. Marquardt, and J.R. Strub Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study Quintessence Int 37 2006 253 259
-
(2006)
Quintessence Int
, vol.37
, pp. 253-259
-
-
Marquardt, P.1
Strub, J.R.2
-
26
-
-
33749065120
-
Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
-
B. Taskonak, and A. Sertgöz Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures Dent Mater 22 2006 1008 1013
-
(2006)
Dent Mater
, vol.22
, pp. 1008-1013
-
-
Taskonak, B.1
Sertgöz, A.2
-
27
-
-
4344684951
-
Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs
-
J.F. Esquivel-Upshaw, K.J. Anusavice, H. Young, J. Jones, and C. Gibbs Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs Int J Prosthodont 17 2004 469 475
-
(2004)
Int J Prosthodont
, vol.17
, pp. 469-475
-
-
Esquivel-Upshaw, J.F.1
Anusavice, K.J.2
Young, H.3
Jones, J.4
Gibbs, C.5
-
28
-
-
0036580615
-
Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM
-
L. Xiao-Ping, T. Jie-Mo, Z. Yun-Long, and W. Ling Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM Dent Mater 1 8 2002 216 220
-
(2002)
Dent Mater
, vol.1
, Issue.8
, pp. 216-220
-
-
Xiao-Ping, L.1
Jie-Mo, T.2
Yun-Long, Z.3
Ling, W.4
-
29
-
-
0034132550
-
Survival of In-Ceram crowns in a private practice: A prospective clinical trial
-
E.A. McLaren, and S.N. White Survival of In-Ceram crowns in a private practice: a prospective clinical trial J Prosthet Dent 83 2000 216 222
-
(2000)
J Prosthet Dent
, vol.83
, pp. 216-222
-
-
McLaren, E.A.1
White, S.N.2
-
30
-
-
0029334452
-
Effect of surface finish on the flexural strength of feldspathic and aluminous dental ceramics
-
R. Giordano, M. Cima, and R. Pober Effect of surface finish on the flexural strength of feldspathic and aluminous dental ceramics Int J Prosthodont 8 1995 311 319
-
(1995)
Int J Prosthodont
, vol.8
, pp. 311-319
-
-
Giordano, R.1
Cima, M.2
Pober, R.3
-
31
-
-
0030208953
-
Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics
-
W.C. Wagner, and T.M. Chu Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics J Prosthet Dent 76 1996 140 144
-
(1996)
J Prosthet Dent
, vol.76
, pp. 140-144
-
-
Wagner, W.C.1
Chu, T.M.2
-
33
-
-
52449088061
-
The clinical success of all-ceramic restorations
-
A. Dalla Bona, and J.R. Kelly The clinical success of all-ceramic restorations J Am Dent Assoc 139 Suppl. 2008 8S 13S
-
(2008)
J Am Dent Assoc
, vol.139
, Issue.SUPPL.
-
-
Dalla Bona, A.1
Kelly, J.R.2
-
34
-
-
0030095844
-
Four year clinical study of glass-infiltrated, sintered alumina crowns
-
L. Probster Four year clinical study of glass-infiltrated, sintered alumina crowns J Oral Rehabil 23 1996 147 151
-
(1996)
J Oral Rehabil
, vol.23
, pp. 147-151
-
-
Probster, L.1
-
36
-
-
0035375073
-
Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice
-
B.S. Segal Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice J Prosthet Dent 85 2001 544 550
-
(2001)
J Prosthet Dent
, vol.85
, pp. 544-550
-
-
Segal, B.S.1
-
38
-
-
12444297515
-
Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
-
M. Kern Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures Quintessence Int 36 2005 141 147
-
(2005)
Quintessence Int
, vol.36
, pp. 141-147
-
-
Kern, M.1
-
39
-
-
0037812257
-
A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
-
K.G. Olsson, B. Fürst, B. Andersson, and G.E. Carlsson A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs Int J Prosthodont 16 2003 150 156
-
(2003)
Int J Prosthodont
, vol.16
, pp. 150-156
-
-
Olsson, K.G.1
Fürst, B.2
Andersson, B.3
Carlsson, G.E.4
-
41
-
-
84980188298
-
Refractory ceramics: I. The forms of zirconium dioxide
-
O. Ruff, and F. Ebert Refractory ceramics: I. The forms of zirconium dioxide Z Anorg Allg Chem 180 1929 19 41
-
(1929)
Z Anorg Allg Chem
, vol.180
, pp. 19-41
-
-
Ruff, O.1
Ebert, F.2
-
43
-
-
38349192796
-
State of the art of zirconia for dental applications
-
I. Denry, and R. Kelly State of the art of zirconia for dental applications Dent Mater 24 2008 299 307
-
(2008)
Dent Mater
, vol.24
, pp. 299-307
-
-
Denry, I.1
Kelly, R.2
-
44
-
-
65349121531
-
Microstructure of alumina- and alumina/zirconia-glass infiltrated dental ceramics
-
M. Guazzato, M. Albakry, M.V. Swain, and S.P. Ringer Microstructure of alumina- and alumina/zirconia-glass infiltrated dental ceramics Bioceramics 15 2003 879 882
-
(2003)
Bioceramics
, vol.15
, pp. 879-882
-
-
Guazzato, M.1
Albakry, M.2
Swain, M.V.3
Ringer, S.P.4
-
45
-
-
1842783267
-
Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
-
M. Guazzato, M. Albakry, S.P. Ringer, and M.V. Swain Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics Dent Mater 20 2004 449 456
-
(2004)
Dent Mater
, vol.20
, pp. 449-456
-
-
Guazzato, M.1
Albakry, M.2
Ringer, S.P.3
Swain, M.V.4
-
46
-
-
1942468620
-
Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics
-
M. Guazzato, K. Proos, L. Quach, and M.V. Swain Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics Biomaterials 25 2004 5045 5052
-
(2004)
Biomaterials
, vol.25
, pp. 5045-5052
-
-
Guazzato, M.1
Proos, K.2
Quach, L.3
Swain, M.V.4
-
47
-
-
0022795124
-
2 containing tetragonal zirconia polycrystals
-
2 containing tetragonal zirconia polycrystals Am Ceram Soc Bull 65 1986 1386 1389
-
(1986)
Am Ceram Soc Bull
, vol.65
, pp. 1386-1389
-
-
Tsukuma, K.1
-
48
-
-
33745727941
-
Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering
-
A. Sundh, and G. Sjögren Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering Dent Mater 22 2006 778 784
-
(2006)
Dent Mater
, vol.22
, pp. 778-784
-
-
Sundh, A.1
Sjögren, G.2
-
49
-
-
59149095716
-
Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks
-
J. Fischer, B. Stawarczyk, A. Trottmann, and C.H. Hämmerle Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks Dent Mater 25 2009 326 330
-
(2009)
Dent Mater
, vol.25
, pp. 326-330
-
-
Fischer, J.1
Stawarczyk, B.2
Trottmann, A.3
Hämmerle, C.H.4
-
50
-
-
60449083274
-
Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites
-
J. Fischer, B. Stawarzcyk, A. Trottmann, and C.H. Hämmerle Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites Dent Mater 25 2009 419 423
-
(2009)
Dent Mater
, vol.25
, pp. 419-423
-
-
Fischer, J.1
Stawarzcyk, B.2
Trottmann, A.3
Hämmerle, C.H.4
-
52
-
-
0032018019
-
Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains
-
K. Zeng, A. Oden, and D. Rowcliffe Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains Int J Prosthodont 11 1998 183 189
-
(1998)
Int J Prosthodont
, vol.11
, pp. 183-189
-
-
Zeng, K.1
Oden, A.2
Rowcliffe, D.3
-
54
-
-
20744444983
-
Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments
-
F. Zarone, R. Sorrentino, F. Vaccaro, S. Russo, and G. De Simone Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments Clin Implant Dent Relat Res 7 Suppl. 1 2005 S95 103
-
(2005)
Clin Implant Dent Relat Res
, vol.7
, Issue.SUPPL. 1
, pp. 95-103
-
-
Zarone, F.1
Sorrentino, R.2
Vaccaro, F.3
Russo, S.4
De Simone, G.5
-
55
-
-
78651254218
-
Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: A 6-year retrospective study
-
R. Sorrentino, L. Galasso, S. Tet, G. De Simone, and F. Zarone Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study Clin Implant Dent Relat Res 2009 [December 17: Epub ahead of print]
-
(2009)
Clin Implant Dent Relat Res
-
-
Sorrentino, R.1
Galasso, L.2
Tet, S.3
De Simone, G.4
Zarone, F.5
-
56
-
-
0031217183
-
A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns
-
F. Sulaiman, J. Chai, L.M. Jameson, and W.T. Wozniak A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns Int J Prosthodont 10 1997 478 484
-
(1997)
Int J Prosthodont
, vol.10
, pp. 478-484
-
-
Sulaiman, F.1
Chai, J.2
Jameson, L.M.3
Wozniak, W.T.4
-
58
-
-
0035502392
-
Procera AllCeram crowns followed for 5 to 10.5 years: A prospective clinical study
-
P. Odman, and B. Andersson Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study Int J Prosthodont 14 2001 504 509
-
(2001)
Int J Prosthodont
, vol.14
, pp. 504-509
-
-
Odman, P.1
Andersson, B.2
-
60
-
-
0034189689
-
Bonding to densely sintered alumina surfaces: Effect of sandblasting and silica coating on shear bond strength of luting cements
-
M. Blixt, E. Adamczak, L.A. Linden, A. Oden, and K. Arvidson Bonding to densely sintered alumina surfaces: effect of sandblasting and silica coating on shear bond strength of luting cements Int J Prosthodont 13 2000 221 226
-
(2000)
Int J Prosthodont
, vol.13
, pp. 221-226
-
-
Blixt, M.1
Adamczak, E.2
Linden, L.A.3
Oden, A.4
Arvidson, K.5
-
61
-
-
34250178106
-
Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions
-
N.U. Zitzmann, M.L. Galindo, E. Hagmann, and C.P. Marinello Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions Int J Prosthodont 20 2007 239 241
-
(2007)
Int J Prosthodont
, vol.20
, pp. 239-241
-
-
Zitzmann, N.U.1
Galindo, M.L.2
Hagmann, E.3
Marinello, C.P.4
-
62
-
-
71649087385
-
Nonlinear visco-elastic finite element analysis of different porcelain veneers configuration
-
R. Sorrentino, D. Apicella, C. Riccio, E. Gherlone, F. Zarone, and R. Aversa Nonlinear visco-elastic finite element analysis of different porcelain veneers configuration J Biomed Mater Res Part B: Appl Biomater 91B 2009 727 736
-
(2009)
J Biomed Mater Res Part B: Appl Biomater
, vol.91
, pp. 727-736
-
-
Sorrentino, R.1
Apicella, D.2
Riccio, C.3
Gherlone, E.4
Zarone, F.5
Aversa, R.6
-
63
-
-
71649110881
-
Acid etching surface treatment of feldspathic, alumina and zirconia ceramics: A micromorphological SEM analysis
-
F. Zarone, R. Sorrentino, F. Vaccaro, T. Traini, S. Russo, and M. Ferrari Acid etching surface treatment of feldspathic, alumina and zirconia ceramics: a micromorphological SEM analysis Int Dent South Afr 8 2006 50 56
-
(2006)
Int Dent South Afr
, vol.8
, pp. 50-56
-
-
Zarone, F.1
Sorrentino, R.2
Vaccaro, F.3
Traini, T.4
Russo, S.5
Ferrari, M.6
-
64
-
-
77953685176
-
Low temperature degradation-aging- of zirconia: A critical review of the relevant aspects in dentistry
-
V. Lughi, and V. Sergo Low temperature degradation-aging- of zirconia: a critical review of the relevant aspects in dentistry Dent Mater 26 2010 807 820
-
(2010)
Dent Mater
, vol.26
, pp. 807-820
-
-
Lughi, V.1
Sergo, V.2
-
66
-
-
0034910048
-
Biological glass coating on ceramic materials: In vitro evaluation using primary osteoblast cultures from healthy and osteopenic rat bone
-
P. Torricelli, E. Verne, C.V. Brovarone, P. Appendino, F. Rustichelli, and A. Krajewski Biological glass coating on ceramic materials: in vitro evaluation using primary osteoblast cultures from healthy and osteopenic rat bone Biomaterials 22 2001 2535 2543
-
(2001)
Biomaterials
, vol.22
, pp. 2535-2543
-
-
Torricelli, P.1
Verne, E.2
Brovarone, C.V.3
Appendino, P.4
Rustichelli, F.5
Krajewski, A.6
-
67
-
-
0037089697
-
Ceramic and PMMA particles differentially affect osteoblast phenotype
-
C.H. Lohmann, D.D. Dean, G. Koster, D. Casasola, G.H. Buchhorn, and U. Fink Ceramic and PMMA particles differentially affect osteoblast phenotype Biomaterials 23 2002 1855 1863
-
(2002)
Biomaterials
, vol.23
, pp. 1855-1863
-
-
Lohmann, C.H.1
Dean, D.D.2
Koster, G.3
Casasola, D.4
Buchhorn, G.H.5
Fink, U.6
-
69
-
-
1642312001
-
Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study
-
A. Scarano, M. Piattelli, S. Caputi, G.A. Favero, and A. Piattelli Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study J Periodontol 75 2004 292 296
-
(2004)
J Periodontol
, vol.75
, pp. 292-296
-
-
Scarano, A.1
Piattelli, M.2
Caputi, S.3
Favero, G.A.4
Piattelli, A.5
-
70
-
-
34547638067
-
SEM evaluation of in situ early bacterial colonization on a Y-TZP ceramic: A pilot study
-
R. Scotti, K.Z. Kantorski, C. Monaco, L.F. Valandro, L. Ciocca, and M.A. Bottino SEM evaluation of in situ early bacterial colonization on a Y-TZP ceramic: a pilot study Int J Prosthodont 20 2007 419 422
-
(2007)
Int J Prosthodont
, vol.20
, pp. 419-422
-
-
Scotti, R.1
Kantorski, K.Z.2
Monaco, C.3
Valandro, L.F.4
Ciocca, L.5
Bottino, M.A.6
-
73
-
-
0032917811
-
Zirconia as a ceramic biomaterial
-
C. Piconi, and G. Maccauro Zirconia as a ceramic biomaterial Biomaterials 20 1999 1 25
-
(1999)
Biomaterials
, vol.20
, pp. 1-25
-
-
Piconi, C.1
MacCauro, G.2
-
74
-
-
0033873591
-
Transformation toughening in zirconia-containing ceramics
-
R.H.J. Hannink, P.M. Kelly, and B.C. Muddle Transformation toughening in zirconia-containing ceramics J Am Ceram Soc 83 2000 461 487
-
(2000)
J Am Ceram Soc
, vol.83
, pp. 461-487
-
-
Hannink, R.H.J.1
Kelly, P.M.2
Muddle, B.C.3
-
75
-
-
0033858120
-
Strength and reliability of surface treated Y-TZP dental ceramics
-
T. Kosmac, C. Oblak, P. Jevnikar, N. Funduk, and L. Marion Strength and reliability of surface treated Y-TZP dental ceramics J Biomed Mater Res 53 2000 304 313
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 304-313
-
-
Kosmac, T.1
Oblak, C.2
Jevnikar, P.3
Funduk, N.4
Marion, L.5
-
76
-
-
16344387546
-
Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing
-
A. Sundh, M. Molin, and G. Sjogren Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing Dent Mater 21 2005 476 482
-
(2005)
Dent Mater
, vol.21
, pp. 476-482
-
-
Sundh, A.1
Molin, M.2
Sjogren, G.3
-
77
-
-
2342500842
-
Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis
-
J. Chevalier, S. Deville, E. Munch, R. Jullian, and F. Lair Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis Biomaterials 25 2004 5539 5545
-
(2004)
Biomaterials
, vol.25
, pp. 5539-5545
-
-
Chevalier, J.1
Deville, S.2
Munch, E.3
Jullian, R.4
Lair, F.5
-
79
-
-
0030105465
-
3 determined by Vickers indentation
-
3 determined by Vickers indentation Scr Mater 34 1996 809 814
-
(1996)
Scr Mater
, vol.34
, pp. 809-814
-
-
Cottom, B.A.1
Mayo, M.J.2
-
80
-
-
0242468093
-
Net-shaping of ceramic components by direct ceramic machining
-
F. Filser, P. Kocher, and L.J. Gauckler Net-shaping of ceramic components by direct ceramic machining Assembly Autom 23 2003 382 390
-
(2003)
Assembly Autom
, vol.23
, pp. 382-390
-
-
Filser, F.1
Kocher, P.2
Gauckler, L.J.3
-
81
-
-
60849133610
-
Zirconia: Established facts and perspectives for a biomaterial in dental implantology
-
M. Hisbergues, S. Vendeville, and P. Vendeville Zirconia: established facts and perspectives for a biomaterial in dental implantology J Biomed Mater Res B Appl Biomater 88 2009 519 529
-
(2009)
J Biomed Mater Res B Appl Biomater
, vol.88
, pp. 519-529
-
-
Hisbergues, M.1
Vendeville, S.2
Vendeville, P.3
-
82
-
-
77958090670
-
Fit of zirconia fixed partial denture: A systematic review
-
J. Abduo, K. Lyons, and M. Swain Fit of zirconia fixed partial denture: a systematic review J Oral Rehabil 14 2010 [Epub ahead of print]
-
(2010)
J Oral Rehabil
, vol.14
-
-
Abduo, J.1
Lyons, K.2
Swain, M.3
-
83
-
-
25144478046
-
Strength and reliability of four-unit all-ceramic posterior bridges
-
H. Lüthy, F. Filser, O. Loeffel, M. Schumacher, L.J. Gauckler, and C.H. Hammerle Strength and reliability of four-unit all-ceramic posterior bridges Dent Mater 21 2005 930 937
-
(2005)
Dent Mater
, vol.21
, pp. 930-937
-
-
Lüthy, H.1
Filser, F.2
Loeffel, O.3
Schumacher, M.4
Gauckler, L.J.5
Hammerle, C.H.6
-
84
-
-
0035351260
-
Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study
-
J. Tinschert, G. Natt, W. Mautsch, M. Augthun, and H. Spiekermann Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study Int J Prosthodont 14 2001 231 238
-
(2001)
Int J Prosthodont
, vol.14
, pp. 231-238
-
-
Tinschert, J.1
Natt, G.2
Mautsch, W.3
Augthun, M.4
Spiekermann, H.5
-
85
-
-
40749093600
-
Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography
-
B. Taskonak, J.A. Griggs, J.J. Mecholsky Jr., and J.H. Yan Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography Dent Mater 24 2008 700 707
-
(2008)
Dent Mater
, vol.24
, pp. 700-707
-
-
Taskonak, B.1
Griggs, J.A.2
Mecholsky Jr., J.J.3
Yan, J.H.4
-
86
-
-
38349162274
-
Stabilized zirconia as a structural ceramic: An overview
-
J.R. Kelly, and I. Denry Stabilized zirconia as a structural ceramic: an overview Dent Mater 24 2008 289 298
-
(2008)
Dent Mater
, vol.24
, pp. 289-298
-
-
Kelly, J.R.1
Denry, I.2
-
87
-
-
85047673230
-
Low temperature degradation of Y-TZP materials
-
J.J. Swab Low temperature degradation of Y-TZP materials J Mater Sci 26 1991 6706 6714
-
(1991)
J Mater Sci
, vol.26
, pp. 6706-6714
-
-
Swab, J.J.1
-
88
-
-
26844583254
-
What future for zirconia as a biomaterial?
-
J. Chevalier What future for zirconia as a biomaterial? Biomaterials 27 2006 535 543
-
(2006)
Biomaterials
, vol.27
, pp. 535-543
-
-
Chevalier, J.1
-
89
-
-
1042263905
-
Microstructure-toughness-wear relationship of tetragonal zirconia ceramics
-
DOI 10.1016/S0955-2219(03)00355-8
-
B. Basu, J. Vleugels, and O. Van Der Biest Microstructure-toughness-wear relationship of tetragonal zirconia ceramics J Eur Ceram Soc 24 2004 2031 2040 (Pubitemid 38201953)
-
(2004)
Journal of the European Ceramic Society
, vol.24
, Issue.7
, pp. 2031-2040
-
-
Basu, B.1
Vleugels, J.2
Van Der Biest, O.3
-
90
-
-
0033748129
-
Influence of humidity on the fretting wear of self-mated tetragonal zirconia ceramics
-
B. Basu, R.G. Vitchev, J. Vleugels, J.P. Celis, and O. Van Der Biest Influence of humidity on the fretting wear of self-mated tetragonal zirconia ceramics Acta Mater 48 2000 2461 2471
-
(2000)
Acta Mater
, vol.48
, pp. 2461-2471
-
-
Basu, B.1
Vitchev, R.G.2
Vleugels, J.3
Celis, J.P.4
Van Der Biest, O.5
-
91
-
-
0035526531
-
Low-temperature aging of zirconia ferrules for optical connectors
-
M.J. Lance, E.M. Vogel, L.A. Reith, and R.W. Cannon Low-temperature aging of zirconia ferrules for optical connectors J Am Ceram Soc 84 2001 2731 2733
-
(2001)
J Am Ceram Soc
, vol.84
, pp. 2731-2733
-
-
Lance, M.J.1
Vogel, E.M.2
Reith, L.A.3
Cannon, R.W.4
-
92
-
-
33947313524
-
2 three-unit fixed partial dentures: Comparison of failure load before and after exposure to a mastication simulator
-
2 three-unit fixed partial dentures: comparison of failure load before and after exposure to a mastication simulator J Oral Rehabil 34 2007 282 290
-
(2007)
J Oral Rehabil
, vol.34
, pp. 282-290
-
-
Att, W.1
Grigoriadou, M.2
Strub, J.R.3
-
93
-
-
9944223028
-
The Lava system for CAD/CAM production of high strenght precision fixed prosthodontics
-
J.A. Sorensen The Lava system for CAD/CAM production of high strenght precision fixed prosthodontics Quintessence Dent Technol 26 2003 57 67
-
(2003)
Quintessence Dent Technol
, vol.26
, pp. 57-67
-
-
Sorensen, J.A.1
-
94
-
-
32644443383
-
(CAD-)/CAM in dental technology
-
S. Witowski (CAD-)/CAM in dental technology Quintessence Dent Technol 28 2005 169 184
-
(2005)
Quintessence Dent Technol
, vol.28
, pp. 169-184
-
-
Witowski, S.1
-
95
-
-
55049125270
-
-
US Patent 6,709,694; March 23
-
Suttor D, Hauptmann H, Schnagl R, Frank S. Coloring ceramics by way of ionic or complex-containing solutions. US Patent 6,709,694; March 23, 2004.
-
(2004)
Coloring Ceramics by Way of Ionic or Complex-containing Solutions
-
-
Suttor, D.1
Hauptmann, H.2
Schnagl, R.3
Frank, S.4
-
96
-
-
78651262006
-
Clinical trials in zirconia: A systematic review
-
B. Al-Amleh, K. Lyons, and M. Swain Clinical trials in zirconia: a systematic review J Oral Rehabil 37 2010 641 652
-
(2010)
J Oral Rehabil
, vol.37
, pp. 641-652
-
-
Al-Amleh, B.1
Lyons, K.2
Swain, M.3
-
97
-
-
0035409693
-
Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system
-
J. Tinschert, G. Natt, W. Mautsch, H. Spiekermann, and K.J. Anusavice Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system Oper Dent 26 2001 367 374
-
(2001)
Oper Dent
, vol.26
, pp. 367-374
-
-
Tinschert, J.1
Natt, G.2
Mautsch, W.3
Spiekermann, H.4
Anusavice, K.J.5
-
98
-
-
59049098603
-
High speed grinding of advanced ceramics: A review
-
H. Huang High speed grinding of advanced ceramics: a review Key Eng Mater 404 2009 11 22
-
(2009)
Key Eng Mater
, vol.404
, pp. 11-22
-
-
Huang, H.1
-
99
-
-
0033222358
-
The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
-
T. Kosmac, C. Oblak, P. Jevnikar, N. Funduk, and L. Marion The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic Dent Mater 15 1999 426 433
-
(1999)
Dent Mater
, vol.15
, pp. 426-433
-
-
Kosmac, T.1
Oblak, C.2
Jevnikar, P.3
Funduk, N.4
Marion, L.5
-
100
-
-
77953247575
-
Damage and reliability of Y-TZP after cementation surface treatment
-
P.C. Guess, Y. Zhang, J.W. Kim, E.D. Rekow, and V.P. Thompson Damage and reliability of Y-TZP after cementation surface treatment J Dent Res 89 2010 592 596
-
(2010)
J Dent Res
, vol.89
, pp. 592-596
-
-
Guess, P.C.1
Zhang, Y.2
Kim, J.W.3
Rekow, E.D.4
Thompson, V.P.5
-
102
-
-
4644309900
-
Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems
-
Y. Zhang, A. Pajares, and B.R. Lawn Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems J Biomed Mater Res B: Appl Biomater 71B 2004 166 171
-
(2004)
J Biomed Mater Res B: Appl Biomater
, vol.71
, pp. 166-171
-
-
Zhang, Y.1
Pajares, A.2
Lawn, B.R.3
-
103
-
-
0037982925
-
Design and production of dental prosthetic restorations: Basic research on dental CAD/CAM technology
-
R. Luthardt, A. Weber, H. Rudolph, C. Schone, S. Quaas, and M. Walter Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology Int J Comput Dent 5 2002 165 176
-
(2002)
Int J Comput Dent
, vol.5
, pp. 165-176
-
-
Luthardt, R.1
Weber, A.2
Rudolph, H.3
Schone, C.4
Quaas, S.5
Walter, M.6
-
104
-
-
16344363996
-
Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic
-
M. Guazzato, M. Albakry, L. Quach, and M.V. Swain Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic Dent Mater 21 2005 454 463
-
(2005)
Dent Mater
, vol.21
, pp. 454-463
-
-
Guazzato, M.1
Albakry, M.2
Quach, L.3
Swain, M.V.4
-
105
-
-
11844264547
-
Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic
-
M. Guazzato, L. Quach, M. Albakry, and M.V. Swain Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic J Dent 33 2005 9 18
-
(2005)
J Dent
, vol.33
, pp. 9-18
-
-
Guazzato, M.1
Quach, L.2
Albakry, M.3
Swain, M.V.4
-
106
-
-
28944447516
-
Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia
-
S. Deville, J. Chevalier, and L. Gremillard Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia Biomaterials 27 2006 2186 2192
-
(2006)
Biomaterials
, vol.27
, pp. 2186-2192
-
-
Deville, S.1
Chevalier, J.2
Gremillard, L.3
-
108
-
-
0043011555
-
Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal
-
K. Matsui, H. Horikoshi, N. Ohmichi, M. Ohgai, H. Yoshida, and Y. Ikuara Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal J Am Ceram Soc 86 2003 1401 1408
-
(2003)
J Am Ceram Soc
, vol.86
, pp. 1401-1408
-
-
Matsui, K.1
Horikoshi, H.2
Ohmichi, N.3
Ohgai, M.4
Yoshida, H.5
Ikuara, Y.6
-
109
-
-
34548107352
-
Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study
-
C. Larsson, L. Holm, N. Lövgren, Y. Kokubo, and P. Vult von Steyern Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study J Oral Rehabil 34 2007 702 709
-
(2007)
J Oral Rehabil
, vol.34
, pp. 702-709
-
-
Larsson, C.1
Holm, L.2
Lövgren, N.3
Kokubo, Y.4
Vult Von Steyern, P.5
-
110
-
-
70449442850
-
Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design
-
Z. Bahat, D.J. Mahmood, and P. Vult von Steyern Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design Swed Dent J 33 2009 149 159
-
(2009)
Swed Dent J
, vol.33
, pp. 149-159
-
-
Bahat, Z.1
Mahmood, D.J.2
Vult Von Steyern, P.3
-
111
-
-
71049124440
-
Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
-
F. Beuer, D. Edelhoff, W. Gernet, and J.A. Sorensen Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) Clin Oral Investig 13 2009 445 451
-
(2009)
Clin Oral Investig
, vol.13
, pp. 445-451
-
-
Beuer, F.1
Edelhoff, D.2
Gernet, W.3
Sorensen, J.A.4
-
112
-
-
67650918068
-
Clinical performance of extended zirconia frameworks for fixed dental prostheses: Two-year results
-
M. Schmitter, K. Mussotter, P. Rammelsberg, T. Stober, B. Ohlmann, and O. Gabbert Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results J Oral Rehabil 36 2009 610 615
-
(2009)
J Oral Rehabil
, vol.36
, pp. 610-615
-
-
Schmitter, M.1
Mussotter, K.2
Rammelsberg, P.3
Stober, T.4
Ohlmann, B.5
Gabbert, O.6
-
113
-
-
0036560045
-
Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
-
W.S. Oh, and K.J. Anusavice Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures J Prosthet Dent 87 2002 536 542
-
(2002)
J Prosthet Dent
, vol.87
, pp. 536-542
-
-
Oh, W.S.1
Anusavice, K.J.2
-
114
-
-
33846044794
-
Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges
-
DOI 10.1016/j.dental.2006.01.011, PII S0109564106000121
-
A.R. Studart, F. Filser, P. Kocher, H. Luthy, and L.J. Gauckler Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges Dent Mater 23 2007 177 185 (Pubitemid 46073097)
-
(2007)
Dental Materials
, vol.23
, Issue.2
, pp. 177-185
-
-
Studart, A.R.1
Filser, F.2
Kocher, P.3
Luthy, H.4
Gauckler, L.J.5
-
115
-
-
1842850520
-
Strength, reliability, and mode of fracture of bilayered porcelain/core ceramics
-
M. Guazzato, K. Proos, G. Sara, and M.V. Swain Strength, reliability, and mode of fracture of bilayered porcelain/core ceramics Int J Prosthodont 17 2004 142 149 (Pubitemid 38490974)
-
(2004)
International Journal of Prosthodontics
, vol.17
, Issue.2
, pp. 142-149
-
-
Guazzato, M.1
Proos, K.2
Sara, G.3
Swain, M.V.4
-
116
-
-
17844402484
-
Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
-
S. Reich, M. Wichmann, E. Nkenke, and P. Proeschel Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems Eur J Oral Sci 113 2005 174 179
-
(2005)
Eur J Oral Sci
, vol.113
, pp. 174-179
-
-
Reich, S.1
Wichmann, M.2
Nkenke, E.3
Proeschel, P.4
-
117
-
-
70350173190
-
Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns
-
M. Comlekoglu, M. Dundar, M. Ozcan, M. Gungor, B. Gokce, and C. Artunc Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns Oper Dent 34 2009 586 592
-
(2009)
Oper Dent
, vol.34
, pp. 586-592
-
-
Comlekoglu, M.1
Dundar, M.2
Ozcan, M.3
Gungor, M.4
Gokce, B.5
Artunc, C.6
-
118
-
-
56749179118
-
Clinical fit of four- unit zirconia posterior fixed dental prostheses
-
S. Reich, K. Kappe, H. Teschner, and J. Schmitt Clinical fit of four- unit zirconia posterior fixed dental prostheses Eur J Oral Sci 116 2008 579 584
-
(2008)
Eur J Oral Sci
, vol.116
, pp. 579-584
-
-
Reich, S.1
Kappe, K.2
Teschner, H.3
Schmitt, J.4
-
119
-
-
32644450664
-
Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks
-
F. Komine, T. Gerds, S. Witkowski, and J.R. Strub Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks Acta Odontol Scand 63 2005 361 366
-
(2005)
Acta Odontol Scand
, vol.63
, pp. 361-366
-
-
Komine, F.1
Gerds, T.2
Witkowski, S.3
Strub, J.R.4
-
120
-
-
36949012997
-
Fit of all-ceramic posterior fixed partial denture frameworks in vitro
-
A. Bindl, and W.H. Mormann Fit of all-ceramic posterior fixed partial denture frameworks in vitro Int J Periodontics Restorative Dent 27 2007 567 575
-
(2007)
Int J Periodontics Restorative Dent
, vol.27
, pp. 567-575
-
-
Bindl, A.1
Mormann, W.H.2
-
121
-
-
65149089178
-
Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
-
P. Kohorst, H. Brinkmann, J. Li, L. Borchers, and M. Stiesch Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems Eur J Oral Sci 117 2009 319 325
-
(2009)
Eur J Oral Sci
, vol.117
, pp. 319-325
-
-
Kohorst, P.1
Brinkmann, H.2
Li, J.3
Borchers, L.4
Stiesch, M.5
-
122
-
-
62849105654
-
Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses
-
W. Att, F. Komine, T. Gerds, and J.R. Strub Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses J Prosthet Dent 101 2009 239 247
-
(2009)
J Prosthet Dent
, vol.101
, pp. 239-247
-
-
Att, W.1
Komine, F.2
Gerds, T.3
Strub, J.R.4
-
123
-
-
33749677224
-
The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
-
A.J. Raigrodski, G.J. Chiche, N. Potiket, J.L. Hochstedler, S.E. Mohamed, and S. Billiot The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study J Prosthet Dent 96 2006 237 244
-
(2006)
J Prosthet Dent
, vol.96
, pp. 237-244
-
-
Raigrodski, A.J.1
Chiche, G.J.2
Potiket, N.3
Hochstedler, J.L.4
Mohamed, S.E.5
Billiot, S.6
-
124
-
-
77449113504
-
Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
-
I. Sailer, J. Gottnerb, S. Kanelb, and C.H. Hämmerle Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up Int J Prosthodont 22 2009 553 560
-
(2009)
Int J Prosthodont
, vol.22
, pp. 553-560
-
-
Sailer, I.1
Gottnerb, J.2
Kanelb, S.3
Hämmerle, C.H.4
-
125
-
-
78651248381
-
Five-year prospective clinical study of posterior three-unit zirconia-based fixed partial dentures
-
CLOI-D-10-00444
-
Sorrentino R, De Simone G, Tet S, Russo S, Zarone F. Five-year prospective clinical study of posterior three-unit zirconia-based fixed partial dentures. Clin Oral Investig 2010;CLOI-D-10-00444.
-
(2010)
Clin Oral Investig
-
-
De Simone, G.1
Tetè, S.2
Russo, S.3
Zarone, F.4
Sorrentino, R.5
-
126
-
-
77649338533
-
Clinical evaluation of posterior all-ceramic FPDs (Cercon): A prospective clinical pilot study
-
M. Tsumita, Y. Kokubo, C. Ohkubo, S. Sakurai, and S. Fukushima Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study J Prosthodont Res 54 2010 102 105
-
(2010)
J Prosthodont Res
, vol.54
, pp. 102-105
-
-
Tsumita, M.1
Kokubo, Y.2
Ohkubo, C.3
Sakurai, S.4
Fukushima, S.5
-
127
-
-
14844364021
-
All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study
-
P. Vult von Steyern, P. Carlson, and K. Nilner All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study J Oral Rehabil 32 2005 180 187
-
(2005)
J Oral Rehabil
, vol.32
, pp. 180-187
-
-
Vult Von Steyern, P.1
Carlson, P.2
Nilner, K.3
-
128
-
-
44849111859
-
Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
-
M.K. Molin, and S.L. Karlsson Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs Int J Prosthodont 21 2008 223 227
-
(2008)
Int J Prosthodont
, vol.21
, pp. 223-227
-
-
Molin, M.K.1
Karlsson, S.L.2
-
129
-
-
34250653055
-
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
-
I. Sailer, A. Fehér, F. Filser, L.J. Gauckler, H. Lüthy, and C.H. Hämmerle Five-year clinical results of zirconia frameworks for posterior fixed partial dentures Int J Prosthodont 20 2007 383 388
-
(2007)
Int J Prosthodont
, vol.20
, pp. 383-388
-
-
Sailer, I.1
Fehér, A.2
Filser, F.3
Gauckler, L.J.4
Lüthy, H.5
Hämmerle, C.H.6
-
130
-
-
33749183091
-
Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up
-
I. Sailer, A. Feher, F. Filser, H. Luthy, L.J. Gauckler, and P. Scharer Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up Quintessence Int 37 2006 685 693
-
(2006)
Quintessence Int
, vol.37
, pp. 685-693
-
-
Sailer, I.1
Feher, A.2
Filser, F.3
Luthy, H.4
Gauckler, L.J.5
Scharer, P.6
-
131
-
-
43749099417
-
HIP zirconia fixed partial dentures: Clinical results after 3 years of clinical service
-
D. Edelhoff, B. Florian, W. Florian, and C. Johnen HIP zirconia fixed partial dentures: clinical results after 3 years of clinical service Quintessence Int 39 2008 459 471
-
(2008)
Quintessence Int
, vol.39
, pp. 459-471
-
-
Edelhoff, D.1
Florian, B.2
Florian, W.3
Johnen, C.4
-
132
-
-
33745810915
-
All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial
-
C. Larsson, P. Vult von Steyern, B. Sunzel, and K. Nilner All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial Swed Dent J 30 2006 45 53
-
(2006)
Swed Dent J
, vol.30
, pp. 45-53
-
-
Larsson, C.1
Vult Von Steyern, P.2
Sunzel, B.3
Nilner, K.4
-
133
-
-
44849090314
-
Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results
-
J. Tinschert, K.A. Schulze, G. Natt, P. Latzke, N. Heussen, and H. Spiekermann Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results Int J Prosthodont 21 2008 217 222
-
(2008)
Int J Prosthodont
, vol.21
, pp. 217-222
-
-
Tinschert, J.1
Schulze, K.A.2
Natt, G.3
Latzke, P.4
Heussen, N.5
Spiekermann, H.6
-
134
-
-
48549103602
-
All-ceramic inlay-retained fixed partial dentures: Preliminary results from a clinical study
-
B. Ohlmann, P. Rammelsberg, M. Schmitter, S. Schwarz, and O. Gabbert All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study J Dent 36 2008 692 696
-
(2008)
J Dent
, vol.36
, pp. 692-696
-
-
Ohlmann, B.1
Rammelsberg, P.2
Schmitter, M.3
Schwarz, S.4
Gabbert, O.5
-
135
-
-
33749185840
-
Prospective clinical trial with conventionally luted zirconia-based fixed partial dentures: 18-month results
-
G. Bornemann Prospective clinical trial with conventionally luted zirconia-based fixed partial dentures: 18-month results J Dent Res 82 Spec. Issue B 2003 117
-
(2003)
J Dent Res
, vol.82
, Issue.B
, pp. 117
-
-
Bornemann, G.1
-
136
-
-
33749159631
-
Clinical evaluation of zirconia-based all-ceramic posterior bridges: Two-year results
-
P. Pospiech, P. Rountree, and F. Nothdurft Clinical evaluation of zirconia-based all-ceramic posterior bridges: two-year results J Dent Res 82 2003 114
-
(2003)
J Dent Res
, vol.82
, pp. 114
-
-
Pospiech, P.1
Rountree, P.2
Nothdurft, F.3
-
137
-
-
57349088199
-
A clinical evaluation of all-ceramic bridges placed in UK general dental practices: First-year results
-
R.J. Crisp, A.J. Cowan, J. Lamb, O. Thompson, N. Tulloch, and F.J. Burke A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results Br Dent J 205 2008 477 482
-
(2008)
Br Dent J
, vol.205
, pp. 477-482
-
-
Crisp, R.J.1
Cowan, A.J.2
Lamb, J.3
Thompson, O.4
Tulloch, N.5
Burke, F.J.6
-
138
-
-
73149124508
-
Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): End abutments vs. cantilever design
-
S. Wolfart, S. Harder, S. Eschbach, F. Lehmann, and M. Kern Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design Eur J Oral Sci 117 2009 741 749
-
(2009)
Eur J Oral Sci
, vol.117
, pp. 741-749
-
-
Wolfart, S.1
Harder, S.2
Eschbach, S.3
Lehmann, F.4
Kern, M.5
-
139
-
-
77952296078
-
Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results
-
M. Roediger, N. Gersdorff, A. Huels, and S. Rinke Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results Int J Prosthodont 23 2010 141 148
-
(2010)
Int J Prosthodont
, vol.23
, pp. 141-148
-
-
Roediger, M.1
Gersdorff, N.2
Huels, A.3
Rinke, S.4
-
140
-
-
59149106280
-
CAD/CAM Zirconia vs. slip-cast glass-infiltrated Alumina/Zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial
-
M. Cehreli, A. Kokat, and K. Akca CAD/CAM Zirconia vs. slip-cast glass-infiltrated Alumina/Zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial J Appl Oral Sci 17 2009 49 55
-
(2009)
J Appl Oral Sci
, vol.17
, pp. 49-55
-
-
Cehreli, M.1
Kokat, A.2
Akca, K.3
-
141
-
-
67650467257
-
A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice
-
A. Ortorp, M. Kihl, and G. Carlsson A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice J Dent 37 2009 731 736
-
(2009)
J Dent
, vol.37
, pp. 731-736
-
-
Ortorp, A.1
Kihl, M.2
Carlsson, G.3
-
142
-
-
2542639442
-
Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
-
R. Glauser, I. Sailer, A. Wohlwend, S. Studer, M. Schibli, and P. Scharer Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study Int J Prosthodont 17 2004 285 290
-
(2004)
Int J Prosthodont
, vol.17
, pp. 285-290
-
-
Glauser, R.1
Sailer, I.2
Wohlwend, A.3
Studer, S.4
Schibli, M.5
Scharer, P.6
-
143
-
-
67650921969
-
Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results
-
A. Zembic, I. Sailer, R. Jung, and C. Hammerle Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results Clin Oral Implants Res 20 2009 802 808
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 802-808
-
-
Zembic, A.1
Sailer, I.2
Jung, R.3
Hammerle, C.4
-
144
-
-
12244286788
-
A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years III. Conventional FPDs
-
DOI 10.1111/j.1600-0501.2004.01119.x
-
K. Tan, B.E. Pjetursson, N.P. Lang, and E.S. Chan A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years Clin Oral Implants Res 15 2004 654 666 (Pubitemid 40115753)
-
(2004)
Clinical Oral Implants Research
, vol.15
, Issue.6
, pp. 654-666
-
-
Tan, K.1
Pjetursson, B.E.2
Lang, N.P.3
Chan, E.S.Y.4
-
146
-
-
21444455550
-
All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems
-
P. Vult von Steyern All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems Swed Dent J Suppl 173 2005 1 69
-
(2005)
Swed Dent J Suppl
, vol.173
, pp. 1-69
-
-
Vult Von Steyern, P.1
-
147
-
-
0033070380
-
Six year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures
-
M. Walter, P.D. Reppel, K. Boning, and W.B. Freesmeyer Six year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures J Oral Rehab 26 1999 91 96
-
(1999)
J Oral Rehab
, vol.26
, pp. 91-96
-
-
Walter, M.1
Reppel, P.D.2
Boning, K.3
Freesmeyer, W.B.4
-
148
-
-
0027356074
-
Comparison of the performance on prosthodontic criteria of several alternative alloys used for fixed crown and partial denture restorations: Department of Veterans Affairs Cooperative Studies project 147
-
R.J. Anderson, G.R. Janes, L.R. Sabella, and H.F. Morris Comparison of the performance on prosthodontic criteria of several alternative alloys used for fixed crown and partial denture restorations: department of Veterans Affairs Cooperative Studies project 147 J Prosthet Dent 69 1993 1 8
-
(1993)
J Prosthet Dent
, vol.69
, pp. 1-8
-
-
Anderson, R.J.1
Janes, G.R.2
Sabella, L.R.3
Morris, H.F.4
-
149
-
-
1942489372
-
Shear strength of core-veneer interface in bi-layered ceramics
-
H.M. Al-Dohan, P. Yaman, J.B. Dennison, M.E. Razzoog, and B.R. Lang Shear strength of core-veneer interface in bi-layered ceramics J Prosthet Dent 91 2004 349 355
-
(2004)
J Prosthet Dent
, vol.91
, pp. 349-355
-
-
Al-Dohan, H.M.1
Yaman, P.2
Dennison, J.B.3
Razzoog, M.E.4
Lang, B.R.5
-
150
-
-
38549111908
-
Fatigue and fracture properties of yttria partially stabilized zirconia crown systems
-
E. Tsalouchou, M.J. Cattell, J.C. Knowles, P. Pittayachawan, and A. McDonald Fatigue and fracture properties of yttria partially stabilized zirconia crown systems Dent Mater 24 2008 308 318
-
(2008)
Dent Mater
, vol.24
, pp. 308-318
-
-
Tsalouchou, E.1
Cattell, M.J.2
Knowles, J.C.3
Pittayachawan, P.4
McDonald, A.5
-
151
-
-
47249084728
-
Effect of zirconia type on its bond strength with different veneer ceramics
-
M.N. Aboushelib, C.J. Kleverlaan, and A.J. Feilzer Effect of zirconia type on its bond strength with different veneer ceramics J Prosthodont 17 2008 401 408
-
(2008)
J Prosthodont
, vol.17
, pp. 401-408
-
-
Aboushelib, M.N.1
Kleverlaan, C.J.2
Feilzer, A.J.3
-
152
-
-
33846344006
-
Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis
-
F. Zarone, R. Sorrentino, T. Traini, D. Di lorio, and S. Caputi Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis Dent Mater 23 2007 296 301
-
(2007)
Dent Mater
, vol.23
, pp. 296-301
-
-
Zarone, F.1
Sorrentino, R.2
Traini, T.3
Di Lorio, D.4
Caputi, S.5
-
153
-
-
67651093995
-
Fatigue testing of two porcelain-zirconia all-ceramic crown systems
-
P.G. Coelho, N.R. Silva, E.A. Bonfante, P.C. Guess, E.D. Rekow, and V.P. Thompson Fatigue testing of two porcelain-zirconia all-ceramic crown systems Dent Mater 25 2009 1122 1127
-
(2009)
Dent Mater
, vol.25
, pp. 1122-1127
-
-
Coelho, P.G.1
Silva, N.R.2
Bonfante, E.A.3
Guess, P.C.4
Rekow, E.D.5
Thompson, V.P.6
-
154
-
-
57449084616
-
High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations
-
F. Beuer, J. Schweiger, M. Eichberger, H.F. Kappert, W. Gernet, and D. Edelhoff High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings-a new fabrication mode for all-ceramic restorations Dent Mater 25 2009 121 128
-
(2009)
Dent Mater
, vol.25
, pp. 121-128
-
-
Beuer, F.1
Schweiger, J.2
Eichberger, M.3
Kappert, H.F.4
Gernet, W.5
Edelhoff, D.6
-
155
-
-
67349133480
-
Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
-
M.V. Swain Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures Acta Biomater 5 2009 1668 1677
-
(2009)
Acta Biomater
, vol.5
, pp. 1668-1677
-
-
Swain, M.V.1
-
156
-
-
70349105523
-
Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process
-
M.P. Dittmer, L. Borchers, M. Stiesch, and P. Kohorst Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process Acta Biomater 5 2009 3231 3239
-
(2009)
Acta Biomater
, vol.5
, pp. 3231-3239
-
-
Dittmer, M.P.1
Borchers, L.2
Stiesch, M.3
Kohorst, P.4
-
157
-
-
84985043470
-
Direct and indirect dissolution of sapphire in calcia-magnesia-alumina- silica melts: Dissolution kinetics
-
K.H. Sandhage, and G.J. Yurek Direct and indirect dissolution of sapphire in calcia-magnesia-alumina-silica melts: dissolution kinetics J Am Ceram Soc 73 1990 3633 3642
-
(1990)
J Am Ceram Soc
, vol.73
, pp. 3633-3642
-
-
Sandhage, K.H.1
Yurek, G.J.2
-
159
-
-
0022679707
-
3-stabilized tetragonal zirconia
-
3-stabilized tetragonal zirconia J Am Ceram Soc 69 1986 270 271
-
(1986)
J Am Ceram Soc
, vol.69
, pp. 270-271
-
-
Schubert, H.1
-
160
-
-
68549115356
-
Consensus report. Ceramics in implant dentistry (Working group I)
-
J.A. Hobkirk, and H.W.A. Wiskott Consensus report. Ceramics in implant dentistry (Working group I) Clin Oral Implants Res 20 Suppl. 4 2009 55 57
-
(2009)
Clin Oral Implants Res
, vol.20
, Issue.SUPPL. 4
, pp. 55-57
-
-
Hobkirk, J.A.1
Wiskott, H.W.A.2
|