메뉴 건너뛰기




Volumn 27, Issue 1, 2011, Pages 83-96

From porcelain-fused-to-metal to zirconia: Clinical and experimental considerations

Author keywords

Alumina; CAD CAM; Dental ceramics; Esthetics; Fixed prosthesis; Zirconia

Indexed keywords

ALL-CERAMIC; CAD/CAMS; CERAMIC RESTORATIONS; CLINICAL EXPERIENCE; CLINICAL STUDY; CONVENTIONAL METALS; DENTAL CERAMIC; ESTHETICS; FIXED PARTIAL DENTURES; FIXED PROSTHESIS; HIGH STRENGTH; IN-VITRO; IN-VIVO; LONG SPAN; MECHANICAL CHARACTERISTICS; MECHANICAL PERFORMANCE; PORCELAIN FUSED TO METALS; PROS AND CONS; RESTORATIVE MATERIALS; SCIENTIFIC EVIDENCE; SCIENTIFIC RESULTS; STRUCTURED REVIEW;

EID: 78651247534     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2010.10.024     Document Type: Article
Times cited : (380)

References (160)
  • 1
    • 0033223147 scopus 로고    scopus 로고
    • A 10-year longitudinal study of fixed prosthodontics: Clinical characteristics and outcome of single-unit metal-ceramic crowns
    • T.R. Walton A 10-year longitudinal study of fixed prosthodontics: clinical characteristics and outcome of single-unit metal-ceramic crowns Int J Prosthodont 12 1999 519 526
    • (1999) Int J Prosthodont , vol.12 , pp. 519-526
    • Walton, T.R.1
  • 2
    • 0035749346 scopus 로고    scopus 로고
    • The metal-free practice: Myth? Reality? Desirable goal?
    • F.M. Spear The metal-free practice: myth? Reality? Desirable goal? J Esthet Restor Dent 13 2001 59 67
    • (2001) J Esthet Restor Dent , vol.13 , pp. 59-67
    • Spear, F.M.1
  • 4
    • 33746913496 scopus 로고    scopus 로고
    • Metal-ceramic failure in noble metal crowns: 7-year results of a prospective clinical trial in private practices
    • B. Reitemeier, K. Hänsel, C. Kastner, and M.H. Walter Metal-ceramic failure in noble metal crowns: 7-year results of a prospective clinical trial in private practices Int J Prosthodont 19 2006 397 399
    • (2006) Int J Prosthodont , vol.19 , pp. 397-399
    • Reitemeier, B.1    Hänsel, K.2    Kastner, C.3    Walter, M.H.4
  • 5
    • 34250612616 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns
    • B.E. Pjetursson, I. Sailer, M. Zwahlen, and C.H. Hämmerle A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns Clin Oral Implants Res 18 Suppl. 3 2007 73 85
    • (2007) Clin Oral Implants Res , vol.18 , Issue.SUPPL. 3 , pp. 73-85
    • Pjetursson, B.E.1    Sailer, I.2    Zwahlen, M.3    Hämmerle, C.H.4
  • 6
    • 34250665803 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses
    • I. Sailer, B.E. Pjetursson, M. Zwahlen, and C.H. Hämmerle A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses Clin Oral Implants Res 18 Suppl. 3 2007 86 96
    • (2007) Clin Oral Implants Res , vol.18 , Issue.SUPPL. 3 , pp. 86-96
    • Sailer, I.1    Pjetursson, B.E.2    Zwahlen, M.3    Hämmerle, C.H.4
  • 7
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • F. Wettstein, I. Sailer, M. Roos, and C.H. Hämmerle Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures Eur J Oral Sci 116 2008 272 279
    • (2008) Eur J Oral Sci , vol.116 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.4
  • 9
    • 52449118551 scopus 로고    scopus 로고
    • Factors essential for successful all-ceramic restorations
    • T.E. Donovan Factors essential for successful all-ceramic restorations J Am Dent Assoc 139 Suppl. 2008 14S 18S
    • (2008) J Am Dent Assoc , vol.139 , Issue.SUPPL.
    • Donovan, T.E.1
  • 10
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: A systematic review
    • H.J. Conrad, W.J. Seong, and I.J. Pesun Current ceramic materials and systems with clinical recommendations: a systematic review J Prosthet Dent 98 2007 389 404
    • (2007) J Prosthet Dent , vol.98 , pp. 389-404
    • Conrad, H.J.1    Seong, W.J.2    Pesun, I.J.3
  • 11
    • 0000653434 scopus 로고
    • The reinforcement of dental porcelain with ceramic oxides
    • L.W. McLean, and T.H. Hughes The reinforcement of dental porcelain with ceramic oxides Br Dent J 119 1965 251 267
    • (1965) Br Dent J , vol.119 , pp. 251-267
    • McLean, L.W.1    Hughes, T.H.2
  • 12
    • 0032608003 scopus 로고    scopus 로고
    • Survival of Dicor glass-ceramic dental restorations over 14 years: Part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age
    • K.A. Malament, and S.S. Socransky Survival of Dicor glass-ceramic dental restorations over 14 years: part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age J Prosthet Dent 81 1999 23 32
    • (1999) J Prosthet Dent , vol.81 , pp. 23-32
    • Malament, K.A.1    Socransky, S.S.2
  • 13
    • 0032620677 scopus 로고    scopus 로고
    • Ceramic restorations for posterior teeth: Guidelines for the clinician
    • A.V. Ritter, and L.N. Baratieri Ceramic restorations for posterior teeth: guidelines for the clinician J Esthet Dent 11 1999 72 86
    • (1999) J Esthet Dent , vol.11 , pp. 72-86
    • Ritter, A.V.1    Baratieri, L.N.2
  • 14
    • 0034264517 scopus 로고    scopus 로고
    • Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics
    • J. Tinschert, D. Zwez, R. Marx, and K.J. Anusavice Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics J Dent 28 2000 529 535
    • (2000) J Dent , vol.28 , pp. 529-535
    • Tinschert, J.1    Zwez, D.2    Marx, R.3    Anusavice, K.J.4
  • 16
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
    • A.J. Raigrodski Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature J Prosthet Dent 92 2004 557 562
    • (2004) J Prosthet Dent , vol.92 , pp. 557-562
    • Raigrodski, A.J.1
  • 17
    • 34547603573 scopus 로고    scopus 로고
    • Flexural strength and fracture toughness of dental core ceramics
    • H. Yilmaz, C. Aydin, and B.E. Gul Flexural strength and fracture toughness of dental core ceramics J Prosthet Dent 98 2007 120 128
    • (2007) J Prosthet Dent , vol.98 , pp. 120-128
    • Yilmaz, H.1    Aydin, C.2    Gul, B.E.3
  • 18
    • 0036652611 scopus 로고    scopus 로고
    • An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: A retrospective study
    • M. Fradeani, and M. Redemagni An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study Quintessence Int 33 2002 503 510
    • (2002) Quintessence Int , vol.33 , pp. 503-510
    • Fradeani, M.1    Redemagni, M.2
  • 20
    • 13444301265 scopus 로고    scopus 로고
    • Porcelain laminate veneers: 6- to 12-year clinical evaluation - A retrospective study
    • M. Fradeani, M. Redemagni, and M. Corrado Porcelain laminate veneers: 6- to 12-year clinical evaluation - a retrospective study Int J Periodontics Restorative Dent 25 2005 9 17
    • (2005) Int J Periodontics Restorative Dent , vol.25 , pp. 9-17
    • Fradeani, M.1    Redemagni, M.2    Corrado, M.3
  • 21
    • 34547639165 scopus 로고    scopus 로고
    • An up to 16-year prospective study of 304 porcelain veneers
    • D. Layton, and T. Walton An up to 16-year prospective study of 304 porcelain veneers Int J Prosthodont 20 2007 389 396
    • (2007) Int J Prosthodont , vol.20 , pp. 389-396
    • Layton, D.1    Walton, T.2
  • 22
    • 52049101566 scopus 로고    scopus 로고
    • Translucency and biaxial flexural strength of four ceramic core materials
    • Y.M. Chen, R.J. Smales, K.H. Yip, and W.J. Sung Translucency and biaxial flexural strength of four ceramic core materials Dent Mater 24 2008 1506 1511
    • (2008) Dent Mater , vol.24 , pp. 1506-1511
    • Chen, Y.M.1    Smales, R.J.2    Yip, K.H.3    Sung, W.J.4
  • 23
    • 33646364586 scopus 로고    scopus 로고
    • Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation
    • C.F. Stappert, W. Att, T. Gerds, and J.R. Strub Fracture resistance of different partial-coverage ceramic molar restorations: an in vitro investigation J Am Dent Assoc 137 2006 514 522
    • (2006) J Am Dent Assoc , vol.137 , pp. 514-522
    • Stappert, C.F.1    Att, W.2    Gerds, T.3    Strub, J.R.4
  • 24
    • 34047214549 scopus 로고    scopus 로고
    • A short-term clinical evaluation of IPS Empress 2 crowns
    • S. Toksavul, and M. Toman A short-term clinical evaluation of IPS Empress 2 crowns Int J Prosthodont 20 2007 168 172
    • (2007) Int J Prosthodont , vol.20 , pp. 168-172
    • Toksavul, S.1    Toman, M.2
  • 25
    • 33645309086 scopus 로고    scopus 로고
    • Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: Results of a 5-year prospective clinical study
    • P. Marquardt, and J.R. Strub Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study Quintessence Int 37 2006 253 259
    • (2006) Quintessence Int , vol.37 , pp. 253-259
    • Marquardt, P.1    Strub, J.R.2
  • 26
    • 33749065120 scopus 로고    scopus 로고
    • Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
    • B. Taskonak, and A. Sertgöz Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures Dent Mater 22 2006 1008 1013
    • (2006) Dent Mater , vol.22 , pp. 1008-1013
    • Taskonak, B.1    Sertgöz, A.2
  • 27
    • 4344684951 scopus 로고    scopus 로고
    • Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs
    • J.F. Esquivel-Upshaw, K.J. Anusavice, H. Young, J. Jones, and C. Gibbs Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs Int J Prosthodont 17 2004 469 475
    • (2004) Int J Prosthodont , vol.17 , pp. 469-475
    • Esquivel-Upshaw, J.F.1    Anusavice, K.J.2    Young, H.3    Jones, J.4    Gibbs, C.5
  • 28
    • 0036580615 scopus 로고    scopus 로고
    • Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM
    • L. Xiao-Ping, T. Jie-Mo, Z. Yun-Long, and W. Ling Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM Dent Mater 1 8 2002 216 220
    • (2002) Dent Mater , vol.1 , Issue.8 , pp. 216-220
    • Xiao-Ping, L.1    Jie-Mo, T.2    Yun-Long, Z.3    Ling, W.4
  • 29
    • 0034132550 scopus 로고    scopus 로고
    • Survival of In-Ceram crowns in a private practice: A prospective clinical trial
    • E.A. McLaren, and S.N. White Survival of In-Ceram crowns in a private practice: a prospective clinical trial J Prosthet Dent 83 2000 216 222
    • (2000) J Prosthet Dent , vol.83 , pp. 216-222
    • McLaren, E.A.1    White, S.N.2
  • 30
    • 0029334452 scopus 로고
    • Effect of surface finish on the flexural strength of feldspathic and aluminous dental ceramics
    • R. Giordano, M. Cima, and R. Pober Effect of surface finish on the flexural strength of feldspathic and aluminous dental ceramics Int J Prosthodont 8 1995 311 319
    • (1995) Int J Prosthodont , vol.8 , pp. 311-319
    • Giordano, R.1    Cima, M.2    Pober, R.3
  • 31
    • 0030208953 scopus 로고    scopus 로고
    • Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics
    • W.C. Wagner, and T.M. Chu Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics J Prosthet Dent 76 1996 140 144
    • (1996) J Prosthet Dent , vol.76 , pp. 140-144
    • Wagner, W.C.1    Chu, T.M.2
  • 32
    • 0036636830 scopus 로고    scopus 로고
    • Mechanical properties of in-ceram alumina and in-ceram zirconia
    • M. Guazzato, M. Albakry, M.V. Swain, and J. Ironside Mechanical properties of in-ceram alumina and in-ceram zirconia Int J Prosthodont 15 2002 339 346
    • (2002) Int J Prosthodont , vol.15 , pp. 339-346
    • Guazzato, M.1    Albakry, M.2    Swain, M.V.3    Ironside, J.4
  • 33
    • 52449088061 scopus 로고    scopus 로고
    • The clinical success of all-ceramic restorations
    • A. Dalla Bona, and J.R. Kelly The clinical success of all-ceramic restorations J Am Dent Assoc 139 Suppl. 2008 8S 13S
    • (2008) J Am Dent Assoc , vol.139 , Issue.SUPPL.
    • Dalla Bona, A.1    Kelly, J.R.2
  • 34
    • 0030095844 scopus 로고    scopus 로고
    • Four year clinical study of glass-infiltrated, sintered alumina crowns
    • L. Probster Four year clinical study of glass-infiltrated, sintered alumina crowns J Oral Rehabil 23 1996 147 151
    • (1996) J Oral Rehabil , vol.23 , pp. 147-151
    • Probster, L.1
  • 35
    • 0034167548 scopus 로고    scopus 로고
    • Clinical assessment of high-strength all-ceramic crowns
    • D.R. Haselton, A.M. Diaz-Arnold, and S.L. Hillis Clinical assessment of high-strength all-ceramic crowns J Prosthet Dent 83 2000 396 401
    • (2000) J Prosthet Dent , vol.83 , pp. 396-401
    • Haselton, D.R.1    Diaz-Arnold, A.M.2    Hillis, S.L.3
  • 36
    • 0035375073 scopus 로고    scopus 로고
    • Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice
    • B.S. Segal Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice J Prosthet Dent 85 2001 544 550
    • (2001) J Prosthet Dent , vol.85 , pp. 544-550
    • Segal, B.S.1
  • 37
    • 0032015941 scopus 로고    scopus 로고
    • In-Ceram fixed partial dentures: Three-year clinical trial results
    • J.A. Sorensen, S.K. Kang, T.J. Torres, and H. Knode In-Ceram fixed partial dentures: three-year clinical trial results J Calif Dent Assoc 26 1998 207 214
    • (1998) J Calif Dent Assoc , vol.26 , pp. 207-214
    • Sorensen, J.A.1    Kang, S.K.2    Torres, T.J.3    Knode, H.4
  • 38
    • 12444297515 scopus 로고    scopus 로고
    • Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
    • M. Kern Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures Quintessence Int 36 2005 141 147
    • (2005) Quintessence Int , vol.36 , pp. 141-147
    • Kern, M.1
  • 39
    • 0037812257 scopus 로고    scopus 로고
    • A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
    • K.G. Olsson, B. Fürst, B. Andersson, and G.E. Carlsson A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs Int J Prosthodont 16 2003 150 156
    • (2003) Int J Prosthodont , vol.16 , pp. 150-156
    • Olsson, K.G.1    Fürst, B.2    Andersson, B.3    Carlsson, G.E.4
  • 41
    • 84980188298 scopus 로고
    • Refractory ceramics: I. The forms of zirconium dioxide
    • O. Ruff, and F. Ebert Refractory ceramics: I. The forms of zirconium dioxide Z Anorg Allg Chem 180 1929 19 41
    • (1929) Z Anorg Allg Chem , vol.180 , pp. 19-41
    • Ruff, O.1    Ebert, F.2
  • 43
    • 38349192796 scopus 로고    scopus 로고
    • State of the art of zirconia for dental applications
    • I. Denry, and R. Kelly State of the art of zirconia for dental applications Dent Mater 24 2008 299 307
    • (2008) Dent Mater , vol.24 , pp. 299-307
    • Denry, I.1    Kelly, R.2
  • 44
    • 65349121531 scopus 로고    scopus 로고
    • Microstructure of alumina- and alumina/zirconia-glass infiltrated dental ceramics
    • M. Guazzato, M. Albakry, M.V. Swain, and S.P. Ringer Microstructure of alumina- and alumina/zirconia-glass infiltrated dental ceramics Bioceramics 15 2003 879 882
    • (2003) Bioceramics , vol.15 , pp. 879-882
    • Guazzato, M.1    Albakry, M.2    Swain, M.V.3    Ringer, S.P.4
  • 45
    • 1842783267 scopus 로고    scopus 로고
    • Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
    • M. Guazzato, M. Albakry, S.P. Ringer, and M.V. Swain Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics Dent Mater 20 2004 449 456
    • (2004) Dent Mater , vol.20 , pp. 449-456
    • Guazzato, M.1    Albakry, M.2    Ringer, S.P.3    Swain, M.V.4
  • 46
    • 1942468620 scopus 로고    scopus 로고
    • Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics
    • M. Guazzato, K. Proos, L. Quach, and M.V. Swain Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics Biomaterials 25 2004 5045 5052
    • (2004) Biomaterials , vol.25 , pp. 5045-5052
    • Guazzato, M.1    Proos, K.2    Quach, L.3    Swain, M.V.4
  • 47
    • 0022795124 scopus 로고
    • 2 containing tetragonal zirconia polycrystals
    • 2 containing tetragonal zirconia polycrystals Am Ceram Soc Bull 65 1986 1386 1389
    • (1986) Am Ceram Soc Bull , vol.65 , pp. 1386-1389
    • Tsukuma, K.1
  • 48
    • 33745727941 scopus 로고    scopus 로고
    • Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering
    • A. Sundh, and G. Sjögren Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering Dent Mater 22 2006 778 784
    • (2006) Dent Mater , vol.22 , pp. 778-784
    • Sundh, A.1    Sjögren, G.2
  • 49
    • 59149095716 scopus 로고    scopus 로고
    • Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks
    • J. Fischer, B. Stawarczyk, A. Trottmann, and C.H. Hämmerle Impact of thermal properties of veneering ceramics on the fracture load of layered Ce-TZP/A nanocomposite frameworks Dent Mater 25 2009 326 330
    • (2009) Dent Mater , vol.25 , pp. 326-330
    • Fischer, J.1    Stawarczyk, B.2    Trottmann, A.3    Hämmerle, C.H.4
  • 50
    • 60449083274 scopus 로고    scopus 로고
    • Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites
    • J. Fischer, B. Stawarzcyk, A. Trottmann, and C.H. Hämmerle Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites Dent Mater 25 2009 419 423
    • (2009) Dent Mater , vol.25 , pp. 419-423
    • Fischer, J.1    Stawarzcyk, B.2    Trottmann, A.3    Hämmerle, C.H.4
  • 52
    • 0032018019 scopus 로고    scopus 로고
    • Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains
    • K. Zeng, A. Oden, and D. Rowcliffe Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains Int J Prosthodont 11 1998 183 189
    • (1998) Int J Prosthodont , vol.11 , pp. 183-189
    • Zeng, K.1    Oden, A.2    Rowcliffe, D.3
  • 54
    • 20744444983 scopus 로고    scopus 로고
    • Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments
    • F. Zarone, R. Sorrentino, F. Vaccaro, S. Russo, and G. De Simone Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments Clin Implant Dent Relat Res 7 Suppl. 1 2005 S95 103
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1 , pp. 95-103
    • Zarone, F.1    Sorrentino, R.2    Vaccaro, F.3    Russo, S.4    De Simone, G.5
  • 55
    • 78651254218 scopus 로고    scopus 로고
    • Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: A 6-year retrospective study
    • R. Sorrentino, L. Galasso, S. Tet, G. De Simone, and F. Zarone Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study Clin Implant Dent Relat Res 2009 [December 17: Epub ahead of print]
    • (2009) Clin Implant Dent Relat Res
    • Sorrentino, R.1    Galasso, L.2    Tet, S.3    De Simone, G.4    Zarone, F.5
  • 56
    • 0031217183 scopus 로고    scopus 로고
    • A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns
    • F. Sulaiman, J. Chai, L.M. Jameson, and W.T. Wozniak A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns Int J Prosthodont 10 1997 478 484
    • (1997) Int J Prosthodont , vol.10 , pp. 478-484
    • Sulaiman, F.1    Chai, J.2    Jameson, L.M.3    Wozniak, W.T.4
  • 58
    • 0035502392 scopus 로고    scopus 로고
    • Procera AllCeram crowns followed for 5 to 10.5 years: A prospective clinical study
    • P. Odman, and B. Andersson Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study Int J Prosthodont 14 2001 504 509
    • (2001) Int J Prosthodont , vol.14 , pp. 504-509
    • Odman, P.1    Andersson, B.2
  • 59
    • 0442272404 scopus 로고    scopus 로고
    • Bond strength of four resin cements to an alumina core
    • W.A. Awliya, P. Yaman, M.E. Razzoog, and J. Dennison Bond strength of four resin cements to an alumina core J Dent Res 75 1996 378
    • (1996) J Dent Res , vol.75 , pp. 378
    • Awliya, W.A.1    Yaman, P.2    Razzoog, M.E.3    Dennison, J.4
  • 60
    • 0034189689 scopus 로고    scopus 로고
    • Bonding to densely sintered alumina surfaces: Effect of sandblasting and silica coating on shear bond strength of luting cements
    • M. Blixt, E. Adamczak, L.A. Linden, A. Oden, and K. Arvidson Bonding to densely sintered alumina surfaces: effect of sandblasting and silica coating on shear bond strength of luting cements Int J Prosthodont 13 2000 221 226
    • (2000) Int J Prosthodont , vol.13 , pp. 221-226
    • Blixt, M.1    Adamczak, E.2    Linden, L.A.3    Oden, A.4    Arvidson, K.5
  • 61
    • 34250178106 scopus 로고    scopus 로고
    • Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions
    • N.U. Zitzmann, M.L. Galindo, E. Hagmann, and C.P. Marinello Clinical evaluation of Procera AllCeram crowns in the anterior and posterior regions Int J Prosthodont 20 2007 239 241
    • (2007) Int J Prosthodont , vol.20 , pp. 239-241
    • Zitzmann, N.U.1    Galindo, M.L.2    Hagmann, E.3    Marinello, C.P.4
  • 63
    • 71649110881 scopus 로고    scopus 로고
    • Acid etching surface treatment of feldspathic, alumina and zirconia ceramics: A micromorphological SEM analysis
    • F. Zarone, R. Sorrentino, F. Vaccaro, T. Traini, S. Russo, and M. Ferrari Acid etching surface treatment of feldspathic, alumina and zirconia ceramics: a micromorphological SEM analysis Int Dent South Afr 8 2006 50 56
    • (2006) Int Dent South Afr , vol.8 , pp. 50-56
    • Zarone, F.1    Sorrentino, R.2    Vaccaro, F.3    Traini, T.4    Russo, S.5    Ferrari, M.6
  • 64
    • 77953685176 scopus 로고    scopus 로고
    • Low temperature degradation-aging- of zirconia: A critical review of the relevant aspects in dentistry
    • V. Lughi, and V. Sergo Low temperature degradation-aging- of zirconia: a critical review of the relevant aspects in dentistry Dent Mater 26 2010 807 820
    • (2010) Dent Mater , vol.26 , pp. 807-820
    • Lughi, V.1    Sergo, V.2
  • 66
    • 0034910048 scopus 로고    scopus 로고
    • Biological glass coating on ceramic materials: In vitro evaluation using primary osteoblast cultures from healthy and osteopenic rat bone
    • P. Torricelli, E. Verne, C.V. Brovarone, P. Appendino, F. Rustichelli, and A. Krajewski Biological glass coating on ceramic materials: in vitro evaluation using primary osteoblast cultures from healthy and osteopenic rat bone Biomaterials 22 2001 2535 2543
    • (2001) Biomaterials , vol.22 , pp. 2535-2543
    • Torricelli, P.1    Verne, E.2    Brovarone, C.V.3    Appendino, P.4    Rustichelli, F.5    Krajewski, A.6
  • 69
    • 1642312001 scopus 로고    scopus 로고
    • Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study
    • A. Scarano, M. Piattelli, S. Caputi, G.A. Favero, and A. Piattelli Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study J Periodontol 75 2004 292 296
    • (2004) J Periodontol , vol.75 , pp. 292-296
    • Scarano, A.1    Piattelli, M.2    Caputi, S.3    Favero, G.A.4    Piattelli, A.5
  • 73
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • C. Piconi, and G. Maccauro Zirconia as a ceramic biomaterial Biomaterials 20 1999 1 25
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    MacCauro, G.2
  • 74
    • 0033873591 scopus 로고    scopus 로고
    • Transformation toughening in zirconia-containing ceramics
    • R.H.J. Hannink, P.M. Kelly, and B.C. Muddle Transformation toughening in zirconia-containing ceramics J Am Ceram Soc 83 2000 461 487
    • (2000) J Am Ceram Soc , vol.83 , pp. 461-487
    • Hannink, R.H.J.1    Kelly, P.M.2    Muddle, B.C.3
  • 76
    • 16344387546 scopus 로고    scopus 로고
    • Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing
    • A. Sundh, M. Molin, and G. Sjogren Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing Dent Mater 21 2005 476 482
    • (2005) Dent Mater , vol.21 , pp. 476-482
    • Sundh, A.1    Molin, M.2    Sjogren, G.3
  • 77
    • 2342500842 scopus 로고    scopus 로고
    • Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis
    • J. Chevalier, S. Deville, E. Munch, R. Jullian, and F. Lair Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis Biomaterials 25 2004 5539 5545
    • (2004) Biomaterials , vol.25 , pp. 5539-5545
    • Chevalier, J.1    Deville, S.2    Munch, E.3    Jullian, R.4    Lair, F.5
  • 79
    • 0030105465 scopus 로고    scopus 로고
    • 3 determined by Vickers indentation
    • 3 determined by Vickers indentation Scr Mater 34 1996 809 814
    • (1996) Scr Mater , vol.34 , pp. 809-814
    • Cottom, B.A.1    Mayo, M.J.2
  • 80
    • 0242468093 scopus 로고    scopus 로고
    • Net-shaping of ceramic components by direct ceramic machining
    • F. Filser, P. Kocher, and L.J. Gauckler Net-shaping of ceramic components by direct ceramic machining Assembly Autom 23 2003 382 390
    • (2003) Assembly Autom , vol.23 , pp. 382-390
    • Filser, F.1    Kocher, P.2    Gauckler, L.J.3
  • 81
    • 60849133610 scopus 로고    scopus 로고
    • Zirconia: Established facts and perspectives for a biomaterial in dental implantology
    • M. Hisbergues, S. Vendeville, and P. Vendeville Zirconia: established facts and perspectives for a biomaterial in dental implantology J Biomed Mater Res B Appl Biomater 88 2009 519 529
    • (2009) J Biomed Mater Res B Appl Biomater , vol.88 , pp. 519-529
    • Hisbergues, M.1    Vendeville, S.2    Vendeville, P.3
  • 82
    • 77958090670 scopus 로고    scopus 로고
    • Fit of zirconia fixed partial denture: A systematic review
    • J. Abduo, K. Lyons, and M. Swain Fit of zirconia fixed partial denture: a systematic review J Oral Rehabil 14 2010 [Epub ahead of print]
    • (2010) J Oral Rehabil , vol.14
    • Abduo, J.1    Lyons, K.2    Swain, M.3
  • 84
    • 0035351260 scopus 로고    scopus 로고
    • Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study
    • J. Tinschert, G. Natt, W. Mautsch, M. Augthun, and H. Spiekermann Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study Int J Prosthodont 14 2001 231 238
    • (2001) Int J Prosthodont , vol.14 , pp. 231-238
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Augthun, M.4    Spiekermann, H.5
  • 85
    • 40749093600 scopus 로고    scopus 로고
    • Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography
    • B. Taskonak, J.A. Griggs, J.J. Mecholsky Jr., and J.H. Yan Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography Dent Mater 24 2008 700 707
    • (2008) Dent Mater , vol.24 , pp. 700-707
    • Taskonak, B.1    Griggs, J.A.2    Mecholsky Jr., J.J.3    Yan, J.H.4
  • 86
    • 38349162274 scopus 로고    scopus 로고
    • Stabilized zirconia as a structural ceramic: An overview
    • J.R. Kelly, and I. Denry Stabilized zirconia as a structural ceramic: an overview Dent Mater 24 2008 289 298
    • (2008) Dent Mater , vol.24 , pp. 289-298
    • Kelly, J.R.1    Denry, I.2
  • 87
    • 85047673230 scopus 로고
    • Low temperature degradation of Y-TZP materials
    • J.J. Swab Low temperature degradation of Y-TZP materials J Mater Sci 26 1991 6706 6714
    • (1991) J Mater Sci , vol.26 , pp. 6706-6714
    • Swab, J.J.1
  • 88
    • 26844583254 scopus 로고    scopus 로고
    • What future for zirconia as a biomaterial?
    • J. Chevalier What future for zirconia as a biomaterial? Biomaterials 27 2006 535 543
    • (2006) Biomaterials , vol.27 , pp. 535-543
    • Chevalier, J.1
  • 89
    • 1042263905 scopus 로고    scopus 로고
    • Microstructure-toughness-wear relationship of tetragonal zirconia ceramics
    • DOI 10.1016/S0955-2219(03)00355-8
    • B. Basu, J. Vleugels, and O. Van Der Biest Microstructure-toughness-wear relationship of tetragonal zirconia ceramics J Eur Ceram Soc 24 2004 2031 2040 (Pubitemid 38201953)
    • (2004) Journal of the European Ceramic Society , vol.24 , Issue.7 , pp. 2031-2040
    • Basu, B.1    Vleugels, J.2    Van Der Biest, O.3
  • 90
    • 0033748129 scopus 로고    scopus 로고
    • Influence of humidity on the fretting wear of self-mated tetragonal zirconia ceramics
    • B. Basu, R.G. Vitchev, J. Vleugels, J.P. Celis, and O. Van Der Biest Influence of humidity on the fretting wear of self-mated tetragonal zirconia ceramics Acta Mater 48 2000 2461 2471
    • (2000) Acta Mater , vol.48 , pp. 2461-2471
    • Basu, B.1    Vitchev, R.G.2    Vleugels, J.3    Celis, J.P.4    Van Der Biest, O.5
  • 91
    • 0035526531 scopus 로고    scopus 로고
    • Low-temperature aging of zirconia ferrules for optical connectors
    • M.J. Lance, E.M. Vogel, L.A. Reith, and R.W. Cannon Low-temperature aging of zirconia ferrules for optical connectors J Am Ceram Soc 84 2001 2731 2733
    • (2001) J Am Ceram Soc , vol.84 , pp. 2731-2733
    • Lance, M.J.1    Vogel, E.M.2    Reith, L.A.3    Cannon, R.W.4
  • 92
    • 33947313524 scopus 로고    scopus 로고
    • 2 three-unit fixed partial dentures: Comparison of failure load before and after exposure to a mastication simulator
    • 2 three-unit fixed partial dentures: comparison of failure load before and after exposure to a mastication simulator J Oral Rehabil 34 2007 282 290
    • (2007) J Oral Rehabil , vol.34 , pp. 282-290
    • Att, W.1    Grigoriadou, M.2    Strub, J.R.3
  • 93
    • 9944223028 scopus 로고    scopus 로고
    • The Lava system for CAD/CAM production of high strenght precision fixed prosthodontics
    • J.A. Sorensen The Lava system for CAD/CAM production of high strenght precision fixed prosthodontics Quintessence Dent Technol 26 2003 57 67
    • (2003) Quintessence Dent Technol , vol.26 , pp. 57-67
    • Sorensen, J.A.1
  • 94
    • 32644443383 scopus 로고    scopus 로고
    • (CAD-)/CAM in dental technology
    • S. Witowski (CAD-)/CAM in dental technology Quintessence Dent Technol 28 2005 169 184
    • (2005) Quintessence Dent Technol , vol.28 , pp. 169-184
    • Witowski, S.1
  • 96
    • 78651262006 scopus 로고    scopus 로고
    • Clinical trials in zirconia: A systematic review
    • B. Al-Amleh, K. Lyons, and M. Swain Clinical trials in zirconia: a systematic review J Oral Rehabil 37 2010 641 652
    • (2010) J Oral Rehabil , vol.37 , pp. 641-652
    • Al-Amleh, B.1    Lyons, K.2    Swain, M.3
  • 97
    • 0035409693 scopus 로고    scopus 로고
    • Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system
    • J. Tinschert, G. Natt, W. Mautsch, H. Spiekermann, and K.J. Anusavice Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system Oper Dent 26 2001 367 374
    • (2001) Oper Dent , vol.26 , pp. 367-374
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Spiekermann, H.4    Anusavice, K.J.5
  • 98
    • 59049098603 scopus 로고    scopus 로고
    • High speed grinding of advanced ceramics: A review
    • H. Huang High speed grinding of advanced ceramics: a review Key Eng Mater 404 2009 11 22
    • (2009) Key Eng Mater , vol.404 , pp. 11-22
    • Huang, H.1
  • 99
    • 0033222358 scopus 로고    scopus 로고
    • The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
    • T. Kosmac, C. Oblak, P. Jevnikar, N. Funduk, and L. Marion The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic Dent Mater 15 1999 426 433
    • (1999) Dent Mater , vol.15 , pp. 426-433
    • Kosmac, T.1    Oblak, C.2    Jevnikar, P.3    Funduk, N.4    Marion, L.5
  • 100
    • 77953247575 scopus 로고    scopus 로고
    • Damage and reliability of Y-TZP after cementation surface treatment
    • P.C. Guess, Y. Zhang, J.W. Kim, E.D. Rekow, and V.P. Thompson Damage and reliability of Y-TZP after cementation surface treatment J Dent Res 89 2010 592 596
    • (2010) J Dent Res , vol.89 , pp. 592-596
    • Guess, P.C.1    Zhang, Y.2    Kim, J.W.3    Rekow, E.D.4    Thompson, V.P.5
  • 102
    • 4644309900 scopus 로고    scopus 로고
    • Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems
    • Y. Zhang, A. Pajares, and B.R. Lawn Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems J Biomed Mater Res B: Appl Biomater 71B 2004 166 171
    • (2004) J Biomed Mater Res B: Appl Biomater , vol.71 , pp. 166-171
    • Zhang, Y.1    Pajares, A.2    Lawn, B.R.3
  • 103
    • 0037982925 scopus 로고    scopus 로고
    • Design and production of dental prosthetic restorations: Basic research on dental CAD/CAM technology
    • R. Luthardt, A. Weber, H. Rudolph, C. Schone, S. Quaas, and M. Walter Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology Int J Comput Dent 5 2002 165 176
    • (2002) Int J Comput Dent , vol.5 , pp. 165-176
    • Luthardt, R.1    Weber, A.2    Rudolph, H.3    Schone, C.4    Quaas, S.5    Walter, M.6
  • 104
    • 16344363996 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic
    • M. Guazzato, M. Albakry, L. Quach, and M.V. Swain Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic Dent Mater 21 2005 454 463
    • (2005) Dent Mater , vol.21 , pp. 454-463
    • Guazzato, M.1    Albakry, M.2    Quach, L.3    Swain, M.V.4
  • 105
    • 11844264547 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic
    • M. Guazzato, L. Quach, M. Albakry, and M.V. Swain Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic J Dent 33 2005 9 18
    • (2005) J Dent , vol.33 , pp. 9-18
    • Guazzato, M.1    Quach, L.2    Albakry, M.3    Swain, M.V.4
  • 106
    • 28944447516 scopus 로고    scopus 로고
    • Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia
    • S. Deville, J. Chevalier, and L. Gremillard Influence of surface finish and residual stresses on the ageing sensitivity of biomedical grade zirconia Biomaterials 27 2006 2186 2192
    • (2006) Biomaterials , vol.27 , pp. 2186-2192
    • Deville, S.1    Chevalier, J.2    Gremillard, L.3
  • 108
    • 0043011555 scopus 로고    scopus 로고
    • Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal
    • K. Matsui, H. Horikoshi, N. Ohmichi, M. Ohgai, H. Yoshida, and Y. Ikuara Cubic-formation and grain-growth mechanisms in tetragonal zirconia polycrystal J Am Ceram Soc 86 2003 1401 1408
    • (2003) J Am Ceram Soc , vol.86 , pp. 1401-1408
    • Matsui, K.1    Horikoshi, H.2    Ohmichi, N.3    Ohgai, M.4    Yoshida, H.5    Ikuara, Y.6
  • 109
    • 34548107352 scopus 로고    scopus 로고
    • Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study
    • C. Larsson, L. Holm, N. Lövgren, Y. Kokubo, and P. Vult von Steyern Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study J Oral Rehabil 34 2007 702 709
    • (2007) J Oral Rehabil , vol.34 , pp. 702-709
    • Larsson, C.1    Holm, L.2    Lövgren, N.3    Kokubo, Y.4    Vult Von Steyern, P.5
  • 110
    • 70449442850 scopus 로고    scopus 로고
    • Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design
    • Z. Bahat, D.J. Mahmood, and P. Vult von Steyern Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design Swed Dent J 33 2009 149 159
    • (2009) Swed Dent J , vol.33 , pp. 149-159
    • Bahat, Z.1    Mahmood, D.J.2    Vult Von Steyern, P.3
  • 111
    • 71049124440 scopus 로고    scopus 로고
    • Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    • F. Beuer, D. Edelhoff, W. Gernet, and J.A. Sorensen Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) Clin Oral Investig 13 2009 445 451
    • (2009) Clin Oral Investig , vol.13 , pp. 445-451
    • Beuer, F.1    Edelhoff, D.2    Gernet, W.3    Sorensen, J.A.4
  • 112
    • 67650918068 scopus 로고    scopus 로고
    • Clinical performance of extended zirconia frameworks for fixed dental prostheses: Two-year results
    • M. Schmitter, K. Mussotter, P. Rammelsberg, T. Stober, B. Ohlmann, and O. Gabbert Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results J Oral Rehabil 36 2009 610 615
    • (2009) J Oral Rehabil , vol.36 , pp. 610-615
    • Schmitter, M.1    Mussotter, K.2    Rammelsberg, P.3    Stober, T.4    Ohlmann, B.5    Gabbert, O.6
  • 113
    • 0036560045 scopus 로고    scopus 로고
    • Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
    • W.S. Oh, and K.J. Anusavice Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures J Prosthet Dent 87 2002 536 542
    • (2002) J Prosthet Dent , vol.87 , pp. 536-542
    • Oh, W.S.1    Anusavice, K.J.2
  • 114
    • 33846044794 scopus 로고    scopus 로고
    • Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges
    • DOI 10.1016/j.dental.2006.01.011, PII S0109564106000121
    • A.R. Studart, F. Filser, P. Kocher, H. Luthy, and L.J. Gauckler Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges Dent Mater 23 2007 177 185 (Pubitemid 46073097)
    • (2007) Dental Materials , vol.23 , Issue.2 , pp. 177-185
    • Studart, A.R.1    Filser, F.2    Kocher, P.3    Luthy, H.4    Gauckler, L.J.5
  • 115
    • 1842850520 scopus 로고    scopus 로고
    • Strength, reliability, and mode of fracture of bilayered porcelain/core ceramics
    • M. Guazzato, K. Proos, G. Sara, and M.V. Swain Strength, reliability, and mode of fracture of bilayered porcelain/core ceramics Int J Prosthodont 17 2004 142 149 (Pubitemid 38490974)
    • (2004) International Journal of Prosthodontics , vol.17 , Issue.2 , pp. 142-149
    • Guazzato, M.1    Proos, K.2    Sara, G.3    Swain, M.V.4
  • 116
    • 17844402484 scopus 로고    scopus 로고
    • Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
    • S. Reich, M. Wichmann, E. Nkenke, and P. Proeschel Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems Eur J Oral Sci 113 2005 174 179
    • (2005) Eur J Oral Sci , vol.113 , pp. 174-179
    • Reich, S.1    Wichmann, M.2    Nkenke, E.3    Proeschel, P.4
  • 117
    • 70350173190 scopus 로고    scopus 로고
    • Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns
    • M. Comlekoglu, M. Dundar, M. Ozcan, M. Gungor, B. Gokce, and C. Artunc Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns Oper Dent 34 2009 586 592
    • (2009) Oper Dent , vol.34 , pp. 586-592
    • Comlekoglu, M.1    Dundar, M.2    Ozcan, M.3    Gungor, M.4    Gokce, B.5    Artunc, C.6
  • 118
    • 56749179118 scopus 로고    scopus 로고
    • Clinical fit of four- unit zirconia posterior fixed dental prostheses
    • S. Reich, K. Kappe, H. Teschner, and J. Schmitt Clinical fit of four- unit zirconia posterior fixed dental prostheses Eur J Oral Sci 116 2008 579 584
    • (2008) Eur J Oral Sci , vol.116 , pp. 579-584
    • Reich, S.1    Kappe, K.2    Teschner, H.3    Schmitt, J.4
  • 119
    • 32644450664 scopus 로고    scopus 로고
    • Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks
    • F. Komine, T. Gerds, S. Witkowski, and J.R. Strub Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks Acta Odontol Scand 63 2005 361 366
    • (2005) Acta Odontol Scand , vol.63 , pp. 361-366
    • Komine, F.1    Gerds, T.2    Witkowski, S.3    Strub, J.R.4
  • 120
    • 36949012997 scopus 로고    scopus 로고
    • Fit of all-ceramic posterior fixed partial denture frameworks in vitro
    • A. Bindl, and W.H. Mormann Fit of all-ceramic posterior fixed partial denture frameworks in vitro Int J Periodontics Restorative Dent 27 2007 567 575
    • (2007) Int J Periodontics Restorative Dent , vol.27 , pp. 567-575
    • Bindl, A.1    Mormann, W.H.2
  • 121
    • 65149089178 scopus 로고    scopus 로고
    • Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    • P. Kohorst, H. Brinkmann, J. Li, L. Borchers, and M. Stiesch Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems Eur J Oral Sci 117 2009 319 325
    • (2009) Eur J Oral Sci , vol.117 , pp. 319-325
    • Kohorst, P.1    Brinkmann, H.2    Li, J.3    Borchers, L.4    Stiesch, M.5
  • 122
    • 62849105654 scopus 로고    scopus 로고
    • Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses
    • W. Att, F. Komine, T. Gerds, and J.R. Strub Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses J Prosthet Dent 101 2009 239 247
    • (2009) J Prosthet Dent , vol.101 , pp. 239-247
    • Att, W.1    Komine, F.2    Gerds, T.3    Strub, J.R.4
  • 123
    • 33749677224 scopus 로고    scopus 로고
    • The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
    • A.J. Raigrodski, G.J. Chiche, N. Potiket, J.L. Hochstedler, S.E. Mohamed, and S. Billiot The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study J Prosthet Dent 96 2006 237 244
    • (2006) J Prosthet Dent , vol.96 , pp. 237-244
    • Raigrodski, A.J.1    Chiche, G.J.2    Potiket, N.3    Hochstedler, J.L.4    Mohamed, S.E.5    Billiot, S.6
  • 124
    • 77449113504 scopus 로고    scopus 로고
    • Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
    • I. Sailer, J. Gottnerb, S. Kanelb, and C.H. Hämmerle Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up Int J Prosthodont 22 2009 553 560
    • (2009) Int J Prosthodont , vol.22 , pp. 553-560
    • Sailer, I.1    Gottnerb, J.2    Kanelb, S.3    Hämmerle, C.H.4
  • 125
    • 78651248381 scopus 로고    scopus 로고
    • Five-year prospective clinical study of posterior three-unit zirconia-based fixed partial dentures
    • CLOI-D-10-00444
    • Sorrentino R, De Simone G, Tet S, Russo S, Zarone F. Five-year prospective clinical study of posterior three-unit zirconia-based fixed partial dentures. Clin Oral Investig 2010;CLOI-D-10-00444.
    • (2010) Clin Oral Investig
    • De Simone, G.1    Tetè, S.2    Russo, S.3    Zarone, F.4    Sorrentino, R.5
  • 126
    • 77649338533 scopus 로고    scopus 로고
    • Clinical evaluation of posterior all-ceramic FPDs (Cercon): A prospective clinical pilot study
    • M. Tsumita, Y. Kokubo, C. Ohkubo, S. Sakurai, and S. Fukushima Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study J Prosthodont Res 54 2010 102 105
    • (2010) J Prosthodont Res , vol.54 , pp. 102-105
    • Tsumita, M.1    Kokubo, Y.2    Ohkubo, C.3    Sakurai, S.4    Fukushima, S.5
  • 127
    • 14844364021 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study
    • P. Vult von Steyern, P. Carlson, and K. Nilner All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study J Oral Rehabil 32 2005 180 187
    • (2005) J Oral Rehabil , vol.32 , pp. 180-187
    • Vult Von Steyern, P.1    Carlson, P.2    Nilner, K.3
  • 128
    • 44849111859 scopus 로고    scopus 로고
    • Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
    • M.K. Molin, and S.L. Karlsson Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs Int J Prosthodont 21 2008 223 227
    • (2008) Int J Prosthodont , vol.21 , pp. 223-227
    • Molin, M.K.1    Karlsson, S.L.2
  • 130
    • 33749183091 scopus 로고    scopus 로고
    • Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up
    • I. Sailer, A. Feher, F. Filser, H. Luthy, L.J. Gauckler, and P. Scharer Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up Quintessence Int 37 2006 685 693
    • (2006) Quintessence Int , vol.37 , pp. 685-693
    • Sailer, I.1    Feher, A.2    Filser, F.3    Luthy, H.4    Gauckler, L.J.5    Scharer, P.6
  • 131
    • 43749099417 scopus 로고    scopus 로고
    • HIP zirconia fixed partial dentures: Clinical results after 3 years of clinical service
    • D. Edelhoff, B. Florian, W. Florian, and C. Johnen HIP zirconia fixed partial dentures: clinical results after 3 years of clinical service Quintessence Int 39 2008 459 471
    • (2008) Quintessence Int , vol.39 , pp. 459-471
    • Edelhoff, D.1    Florian, B.2    Florian, W.3    Johnen, C.4
  • 132
    • 33745810915 scopus 로고    scopus 로고
    • All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial
    • C. Larsson, P. Vult von Steyern, B. Sunzel, and K. Nilner All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial Swed Dent J 30 2006 45 53
    • (2006) Swed Dent J , vol.30 , pp. 45-53
    • Larsson, C.1    Vult Von Steyern, P.2    Sunzel, B.3    Nilner, K.4
  • 133
  • 134
    • 48549103602 scopus 로고    scopus 로고
    • All-ceramic inlay-retained fixed partial dentures: Preliminary results from a clinical study
    • B. Ohlmann, P. Rammelsberg, M. Schmitter, S. Schwarz, and O. Gabbert All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study J Dent 36 2008 692 696
    • (2008) J Dent , vol.36 , pp. 692-696
    • Ohlmann, B.1    Rammelsberg, P.2    Schmitter, M.3    Schwarz, S.4    Gabbert, O.5
  • 135
    • 33749185840 scopus 로고    scopus 로고
    • Prospective clinical trial with conventionally luted zirconia-based fixed partial dentures: 18-month results
    • G. Bornemann Prospective clinical trial with conventionally luted zirconia-based fixed partial dentures: 18-month results J Dent Res 82 Spec. Issue B 2003 117
    • (2003) J Dent Res , vol.82 , Issue.B , pp. 117
    • Bornemann, G.1
  • 136
    • 33749159631 scopus 로고    scopus 로고
    • Clinical evaluation of zirconia-based all-ceramic posterior bridges: Two-year results
    • P. Pospiech, P. Rountree, and F. Nothdurft Clinical evaluation of zirconia-based all-ceramic posterior bridges: two-year results J Dent Res 82 2003 114
    • (2003) J Dent Res , vol.82 , pp. 114
    • Pospiech, P.1    Rountree, P.2    Nothdurft, F.3
  • 137
    • 57349088199 scopus 로고    scopus 로고
    • A clinical evaluation of all-ceramic bridges placed in UK general dental practices: First-year results
    • R.J. Crisp, A.J. Cowan, J. Lamb, O. Thompson, N. Tulloch, and F.J. Burke A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results Br Dent J 205 2008 477 482
    • (2008) Br Dent J , vol.205 , pp. 477-482
    • Crisp, R.J.1    Cowan, A.J.2    Lamb, J.3    Thompson, O.4    Tulloch, N.5    Burke, F.J.6
  • 138
    • 73149124508 scopus 로고    scopus 로고
    • Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): End abutments vs. cantilever design
    • S. Wolfart, S. Harder, S. Eschbach, F. Lehmann, and M. Kern Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design Eur J Oral Sci 117 2009 741 749
    • (2009) Eur J Oral Sci , vol.117 , pp. 741-749
    • Wolfart, S.1    Harder, S.2    Eschbach, S.3    Lehmann, F.4    Kern, M.5
  • 139
    • 77952296078 scopus 로고    scopus 로고
    • Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results
    • M. Roediger, N. Gersdorff, A. Huels, and S. Rinke Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results Int J Prosthodont 23 2010 141 148
    • (2010) Int J Prosthodont , vol.23 , pp. 141-148
    • Roediger, M.1    Gersdorff, N.2    Huels, A.3    Rinke, S.4
  • 140
    • 59149106280 scopus 로고    scopus 로고
    • CAD/CAM Zirconia vs. slip-cast glass-infiltrated Alumina/Zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial
    • M. Cehreli, A. Kokat, and K. Akca CAD/CAM Zirconia vs. slip-cast glass-infiltrated Alumina/Zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial J Appl Oral Sci 17 2009 49 55
    • (2009) J Appl Oral Sci , vol.17 , pp. 49-55
    • Cehreli, M.1    Kokat, A.2    Akca, K.3
  • 141
    • 67650467257 scopus 로고    scopus 로고
    • A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice
    • A. Ortorp, M. Kihl, and G. Carlsson A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice J Dent 37 2009 731 736
    • (2009) J Dent , vol.37 , pp. 731-736
    • Ortorp, A.1    Kihl, M.2    Carlsson, G.3
  • 142
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
    • R. Glauser, I. Sailer, A. Wohlwend, S. Studer, M. Schibli, and P. Scharer Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study Int J Prosthodont 17 2004 285 290
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlwend, A.3    Studer, S.4    Schibli, M.5    Scharer, P.6
  • 143
    • 67650921969 scopus 로고    scopus 로고
    • Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results
    • A. Zembic, I. Sailer, R. Jung, and C. Hammerle Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results Clin Oral Implants Res 20 2009 802 808
    • (2009) Clin Oral Implants Res , vol.20 , pp. 802-808
    • Zembic, A.1    Sailer, I.2    Jung, R.3    Hammerle, C.4
  • 144
    • 12244286788 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years III. Conventional FPDs
    • DOI 10.1111/j.1600-0501.2004.01119.x
    • K. Tan, B.E. Pjetursson, N.P. Lang, and E.S. Chan A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years Clin Oral Implants Res 15 2004 654 666 (Pubitemid 40115753)
    • (2004) Clinical Oral Implants Research , vol.15 , Issue.6 , pp. 654-666
    • Tan, K.1    Pjetursson, B.E.2    Lang, N.P.3    Chan, E.S.Y.4
  • 146
    • 21444455550 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems
    • P. Vult von Steyern All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems Swed Dent J Suppl 173 2005 1 69
    • (2005) Swed Dent J Suppl , vol.173 , pp. 1-69
    • Vult Von Steyern, P.1
  • 147
    • 0033070380 scopus 로고    scopus 로고
    • Six year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures
    • M. Walter, P.D. Reppel, K. Boning, and W.B. Freesmeyer Six year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures J Oral Rehab 26 1999 91 96
    • (1999) J Oral Rehab , vol.26 , pp. 91-96
    • Walter, M.1    Reppel, P.D.2    Boning, K.3    Freesmeyer, W.B.4
  • 148
    • 0027356074 scopus 로고
    • Comparison of the performance on prosthodontic criteria of several alternative alloys used for fixed crown and partial denture restorations: Department of Veterans Affairs Cooperative Studies project 147
    • R.J. Anderson, G.R. Janes, L.R. Sabella, and H.F. Morris Comparison of the performance on prosthodontic criteria of several alternative alloys used for fixed crown and partial denture restorations: department of Veterans Affairs Cooperative Studies project 147 J Prosthet Dent 69 1993 1 8
    • (1993) J Prosthet Dent , vol.69 , pp. 1-8
    • Anderson, R.J.1    Janes, G.R.2    Sabella, L.R.3    Morris, H.F.4
  • 150
    • 38549111908 scopus 로고    scopus 로고
    • Fatigue and fracture properties of yttria partially stabilized zirconia crown systems
    • E. Tsalouchou, M.J. Cattell, J.C. Knowles, P. Pittayachawan, and A. McDonald Fatigue and fracture properties of yttria partially stabilized zirconia crown systems Dent Mater 24 2008 308 318
    • (2008) Dent Mater , vol.24 , pp. 308-318
    • Tsalouchou, E.1    Cattell, M.J.2    Knowles, J.C.3    Pittayachawan, P.4    McDonald, A.5
  • 151
    • 47249084728 scopus 로고    scopus 로고
    • Effect of zirconia type on its bond strength with different veneer ceramics
    • M.N. Aboushelib, C.J. Kleverlaan, and A.J. Feilzer Effect of zirconia type on its bond strength with different veneer ceramics J Prosthodont 17 2008 401 408
    • (2008) J Prosthodont , vol.17 , pp. 401-408
    • Aboushelib, M.N.1    Kleverlaan, C.J.2    Feilzer, A.J.3
  • 152
    • 33846344006 scopus 로고    scopus 로고
    • Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis
    • F. Zarone, R. Sorrentino, T. Traini, D. Di lorio, and S. Caputi Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis Dent Mater 23 2007 296 301
    • (2007) Dent Mater , vol.23 , pp. 296-301
    • Zarone, F.1    Sorrentino, R.2    Traini, T.3    Di Lorio, D.4    Caputi, S.5
  • 154
    • 57449084616 scopus 로고    scopus 로고
    • High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations
    • F. Beuer, J. Schweiger, M. Eichberger, H.F. Kappert, W. Gernet, and D. Edelhoff High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings-a new fabrication mode for all-ceramic restorations Dent Mater 25 2009 121 128
    • (2009) Dent Mater , vol.25 , pp. 121-128
    • Beuer, F.1    Schweiger, J.2    Eichberger, M.3    Kappert, H.F.4    Gernet, W.5    Edelhoff, D.6
  • 155
    • 67349133480 scopus 로고    scopus 로고
    • Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures
    • M.V. Swain Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures Acta Biomater 5 2009 1668 1677
    • (2009) Acta Biomater , vol.5 , pp. 1668-1677
    • Swain, M.V.1
  • 156
    • 70349105523 scopus 로고    scopus 로고
    • Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process
    • M.P. Dittmer, L. Borchers, M. Stiesch, and P. Kohorst Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process Acta Biomater 5 2009 3231 3239
    • (2009) Acta Biomater , vol.5 , pp. 3231-3239
    • Dittmer, M.P.1    Borchers, L.2    Stiesch, M.3    Kohorst, P.4
  • 157
    • 84985043470 scopus 로고
    • Direct and indirect dissolution of sapphire in calcia-magnesia-alumina- silica melts: Dissolution kinetics
    • K.H. Sandhage, and G.J. Yurek Direct and indirect dissolution of sapphire in calcia-magnesia-alumina-silica melts: dissolution kinetics J Am Ceram Soc 73 1990 3633 3642
    • (1990) J Am Ceram Soc , vol.73 , pp. 3633-3642
    • Sandhage, K.H.1    Yurek, G.J.2
  • 159
    • 0022679707 scopus 로고
    • 3-stabilized tetragonal zirconia
    • 3-stabilized tetragonal zirconia J Am Ceram Soc 69 1986 270 271
    • (1986) J Am Ceram Soc , vol.69 , pp. 270-271
    • Schubert, H.1
  • 160
    • 68549115356 scopus 로고    scopus 로고
    • Consensus report. Ceramics in implant dentistry (Working group I)
    • J.A. Hobkirk, and H.W.A. Wiskott Consensus report. Ceramics in implant dentistry (Working group I) Clin Oral Implants Res 20 Suppl. 4 2009 55 57
    • (2009) Clin Oral Implants Res , vol.20 , Issue.SUPPL. 4 , pp. 55-57
    • Hobkirk, J.A.1    Wiskott, H.W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.