메뉴 건너뛰기




Volumn 117, Issue 3, 2009, Pages 319-325

Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems

Author keywords

All ceramic; Computer aided design computer aided manufacturing (CAD CAM); Fixed dental prosthesis; Marginal fit; Zirconia

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 65149089178     PISSN: 09098836     EISSN: 16000722     Source Type: Journal    
DOI: 10.1111/j.1600-0722.2009.00622.x     Document Type: Article
Times cited : (100)

References (39)
  • 2
    • 44249116685 scopus 로고    scopus 로고
    • Digital dentistry: An overview of recent developments of CAD/CAM generated restorations
    • Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments of CAD/CAM generated restorations. Br Dent J 2008 204 : 505 511.
    • (2008) Br Dent J , vol.204 , pp. 505-511
    • Beuer, F.1    Schweiger, J.2    Edelhoff, D.3
  • 3
    • 0035409693 scopus 로고    scopus 로고
    • Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system
    • Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001 26 : 367 374.
    • (2001) Oper Dent , vol.26 , pp. 367-374
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Spiekermann, H.4    Anusavice, K.J.5
  • 4
    • 14844364021 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study
    • DOI 10.1111/j.1365-2842.2004.01437.x
    • Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005 32 : 180 187. (Pubitemid 40353824)
    • (2005) Journal of Oral Rehabilitation , vol.32 , Issue.3 , pp. 180-187
    • Vult Von Steyern, P.1    Carlson, P.2    Nilner, K.3
  • 6
    • 0035495965 scopus 로고    scopus 로고
    • Computer-assisted generation of all-ceramic crowns and fixed partial dentures
    • Besimo CE, Spielmann HP, Rohner HP. Computer-assisted generation of all-ceramic crowns and fixed partial dentures. Int J Comput Dent 2001 4 : 243 262.
    • (2001) Int J Comput Dent , vol.4 , pp. 243-262
    • Besimo, C.E.1    Spielmann, H.P.2    Rohner, H.P.3
  • 8
    • 36949012997 scopus 로고    scopus 로고
    • Fit of all-ceramic posterior fixed partial denture frameworks in vitro
    • Bindl A, Mörmann WH. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent 2007 27 : 567 575.
    • (2007) Int J Periodontics Restorative Dent , vol.27 , pp. 567-575
    • Bindl, A.1    Mörmann, W.H.2
  • 9
    • 34247491685 scopus 로고    scopus 로고
    • Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks
    • Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci 2007 115 : 161 166.
    • (2007) Eur J Oral Sci , vol.115 , pp. 161-166
    • Kohorst, P.1    Herzog, T.J.2    Borchers, L.3    Stiesch-Scholz, M.4
  • 10
    • 48449093726 scopus 로고    scopus 로고
    • Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia
    • Kohorst P, Dittmer MP, Borchers L, Stiesch-Scholz M. Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia. Acta Biomater 2008 4 : 1440 1447.
    • (2008) Acta Biomater , vol.4 , pp. 1440-1447
    • Kohorst, P.1    Dittmer, M.P.2    Borchers, L.3    Stiesch-Scholz, M.4
  • 11
    • 56749179118 scopus 로고    scopus 로고
    • Clinical fit of four-unit zirconia posterior fixed dental prostheses
    • Reich S, Kappe K, Teschner H, Schmitt J. Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 2008 116 : 579 584.
    • (2008) Eur J Oral Sci , vol.116 , pp. 579-584
    • Reich, S.1    Kappe, K.2    Teschner, H.3    Schmitt, J.4
  • 12
    • 57349196555 scopus 로고    scopus 로고
    • Marginal and internal fits of fixed dental prostheses zirconia retainers
    • Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009 25 : 94 102.
    • (2009) Dent Mater , vol.25 , pp. 94-102
    • Beuer, F.1    Aggstaller, H.2    Edelhoff, D.3    Gernet, W.4    Sorensen, J.5
  • 13
    • 69649103465 scopus 로고    scopus 로고
    • Precision of fit: Zirconia three-unit fixed dental prostheses
    • doi. [e-pub ahead of print].
    • Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig 2008 doi : [e-pub ahead of print].
    • (2008) Clin Oral Investig
    • Beuer, F.1    Naumann, M.2    Gernet, W.3    Sorensen, J.A.4
  • 14
    • 17844402484 scopus 로고    scopus 로고
    • Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
    • DOI 10.1111/j.1600-0722.2004.00197.x
    • Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005 113 : 174 179. (Pubitemid 40592286)
    • (2005) European Journal of Oral Sciences , vol.113 , Issue.2 , pp. 174-179
    • Reich, S.1    Wichmann, M.2    Nkenke, E.3    Proeschel, P.4
  • 15
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • Wettstein F, Sailer I, Roos M, Hämmerle CHF. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008 116 : 272 279.
    • (2008) Eur J Oral Sci , vol.116 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.F.4
  • 17
    • 5444219837 scopus 로고    scopus 로고
    • Precision of a CAD/CAM technique for the production of zirconium dioxide copings
    • Coli P, Karlsson S. Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont 2004 17 : 577 580. (Pubitemid 39360701)
    • (2004) International Journal of Prosthodontics , vol.17 , Issue.5 , pp. 577-580
    • Coli, P.1    Karlsson, S.2
  • 20
    • 0020850773 scopus 로고
    • Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins
    • Lang NP, Kiel RA, Anderhalden K. Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 1983 10 : 563 578.
    • (1983) J Clin Periodontol , vol.10 , pp. 563-578
    • Lang, N.P.1    Kiel, R.A.2    Anderhalden, K.3
  • 21
    • 0034328155 scopus 로고    scopus 로고
    • Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures
    • Koernschild KL, Campbell SD. Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 2000 84 : 492 498.
    • (2000) J Prosthet Dent , vol.84 , pp. 492-498
    • Koernschild, K.L.1    Campbell, S.D.2
  • 22
    • 0026127426 scopus 로고
    • Effect of in vivo crown margin discrepancies on periodontal health
    • Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991 65 : 357 364.
    • (1991) J Prosthet Dent , vol.65 , pp. 357-364
    • Felton, D.A.1    Kanoy, B.E.2    Bayne, S.C.3    Wirthman, G.P.4
  • 23
    • 0026934955 scopus 로고
    • Microleakage - Full crowns and the dental pulp
    • Goldman M, Laosonthorn P, White RR. Microleakage - full crowns and the dental pulp. J Endod 1992 18 : 473 475.
    • (1992) J Endod , vol.18 , pp. 473-475
    • Goldman, M.1    Laosonthorn, P.2    White, R.R.3
  • 24
    • 22944491129 scopus 로고    scopus 로고
    • Near-surface damage - A persitent problem in crowns obtained by computer-aided design and manufacturing
    • Rekow D, Thompson VP. Near-surface damage - a persitent problem in crowns obtained by computer-aided design and manufacturing. Proc Inst Mech Eng [H] 2005 219 : 233 243.
    • (2005) Proc Inst Mech Eng [H] , vol.219 , pp. 233-243
    • Rekow, D.1    Thompson, V.P.2
  • 25
    • 44849111859 scopus 로고    scopus 로고
    • Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
    • Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 2008 21 : 223 227.
    • (2008) Int J Prosthodont , vol.21 , pp. 223-227
    • Molin, M.K.1    Karlsson, S.L.2
  • 28
    • 32644450664 scopus 로고    scopus 로고
    • Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks
    • DOI 10.1080/00016350500264313, PII P446431122706432
    • Komine F, Gerds T, Witkowski S, Strub JR. Influence of framework configuration on the marginal adaption of zirconium dioxide ceramic anterior four-unit frameworks. Acta Odontol Scand 2005 63 : 361 366. (Pubitemid 43240802)
    • (2005) Acta Odontologica Scandinavica , vol.63 , Issue.6 , pp. 361-366
    • Komine, F.1    Gerds, T.2    Witkowski, S.3    Strub, J.R.4
  • 29
    • 57349101666 scopus 로고    scopus 로고
    • An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles
    • Vigolo P, Fonzi F. An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures, generated with three different CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles. J Prosthodont 2008 17 : 621 626.
    • (2008) J Prosthodont , vol.17 , pp. 621-626
    • Vigolo, P.1    Fonzi, F.2
  • 31
  • 32
    • 0028476137 scopus 로고
    • A comparison of the fit of spark-eroded titanium copings and cast gold alloy copings
    • Harris IR, Wickens JL. A comparison of the fit of spark-eroded titanium copings and cast gold alloy copings. Int J Prosthodont 1994 7 : 348 355.
    • (1994) Int J Prosthodont , vol.7 , pp. 348-355
    • Harris, I.R.1    Wickens, J.L.2
  • 33
    • 38149014578 scopus 로고    scopus 로고
    • Clinical evaluation of the marginal fit of cast crowns - Validation of the silicone replica method
    • Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns - validation of the silicone replica method. J Oral Rehabil 2008 35 : 116 122.
    • (2008) J Oral Rehabil , vol.35 , pp. 116-122
    • Laurent, M.1    Scheer, P.2    Dejou, J.3    Laborde, G.4
  • 34
    • 39449139427 scopus 로고    scopus 로고
    • In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns
    • Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns. J Contemp Dent Pract 2008 9 : 25 32.
    • (2008) J Contemp Dent Pract , vol.9 , pp. 25-32
    • Rahme, H.Y.1    Tehini, G.E.2    Adib, S.M.3    Ardo, A.S.4    Rifai, K.T.5
  • 35
    • 0022124846 scopus 로고
    • Cavity design and mathematics: Their effect on gaps at the margins of cast restorations
    • Ostlund LE. Cavity design and mathematics: their effect on gaps at the margins of cast restorations. Oper Dent 1985 10 : 122 137.
    • (1985) Oper Dent , vol.10 , pp. 122-137
    • Ostlund, L.E.1
  • 38
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • McLean JW, von Frauenhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971 131 : 107 111.
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Von Frauenhofer, J.A.2
  • 39


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.