메뉴 건너뛰기




Volumn 32, Issue 3, 2005, Pages 180-187

All-ceramic fixed partial dentures designed according to the DC-Zirkon® technique. A 2-year clinical study

Author keywords

All ceramics; Dental porcelain; Fixed partial dentures

Indexed keywords

TOOTH CEMENT; ZINC PHOSPHATE;

EID: 14844364021     PISSN: 0305182X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2004.01437.x     Document Type: Article
Times cited : (291)

References (41)
  • 1
    • 0035408488 scopus 로고    scopus 로고
    • Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs
    • Vult von Steyern P, Jönsson O, Nilner K. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont. 2001;14:379-384.
    • (2001) Int J Prosthodont , vol.14 , pp. 379-384
    • Von Vult Steyern, P.1    Jönsson, O.2    Nilner, K.3
  • 3
    • 8844247554 scopus 로고
    • The nature of dental ceramics and their clinincal use
    • Chicago: Quintessence Publishing Co., Inc.
    • McLean J. The nature of dental ceramics and their clinincal use. In: The Science and Art of Dental Ceramics. Chicago: Quintessence Publishing Co., Inc.; 1979.
    • (1979) The Science and Art of Dental Ceramics
    • McLean, J.1
  • 4
    • 0032062509 scopus 로고    scopus 로고
    • Investigation of the dry and wet fatigue properties of three all-ceramic crown systems
    • Sobrhino LC, Cattel MJ, Glover RH, Knowels JC. Investigation of the dry and wet fatigue properties of three all-ceramic crown systems. Int J Prosthodont. 1998;11:255-262.
    • (1998) Int J Prosthodont , vol.11 , pp. 255-262
    • Sobrhino, L.C.1    Cattel, M.J.2    Glover, R.H.3    Knowels, J.C.4
  • 5
    • 0029258806 scopus 로고
    • Perspectives on strength
    • Kelly JR. Perspectives on strength. Dent Mater. 1995;11:103-110.
    • (1995) Dent Mater , vol.11 , pp. 103-110
    • Kelly, J.R.1
  • 6
    • 0029258587 scopus 로고
    • Predicting lifetimes of materials and material structures
    • Ritter JE. Predicting lifetimes of materials and material structures. Dent Mater. 1995;11:142-146.
    • (1995) Dent Mater , vol.11 , pp. 142-146
    • Ritter, J.E.1
  • 7
    • 0032018397 scopus 로고    scopus 로고
    • All-ceramic alternatives to conventional metal ceramic restorations
    • McLaren EA. All-ceramic alternatives to conventional metal ceramic restorations. Compend Contin Educ Dent. 1998;3:307-325.
    • (1998) Compend Contin Educ Dent , vol.3 , pp. 307-325
    • McLaren, E.A.1
  • 8
    • 0032015941 scopus 로고    scopus 로고
    • In-Ceram fixed partial dentures: Three-year clinical trial results
    • Sorensen JA, Kang SK, Torres TJ, Knode H. In-Ceram fixed partial dentures: three-year clinical trial results. J Calif Dent Assoc. 1998;26:207-14.
    • (1998) J Calif Dent Assoc , vol.26 , pp. 207-214
    • Sorensen, J.A.1    Kang, S.K.2    Torres, T.J.3    Knode, H.4
  • 9
    • 0027604308 scopus 로고
    • Survival rate of In-Ceram restorations
    • Pröbster L. Survival rate of In-Ceram restorations. Int J Prosthodont. 1993;6:259-263.
    • (1993) Int J Prosthodont , vol.6 , pp. 259-263
    • Pröbster, L.1
  • 10
    • 0037812257 scopus 로고    scopus 로고
    • A long-term retrospective and clinical follow-up study of In-Ceram alumina FPDs
    • Olsson KG, Fürst B, Andersson B, Carlsson GE. A long-term retrospective and clinical follow-up study of In-Ceram alumina FPDs. Int J Prosthodont. 2003;16:150-156.
    • (2003) Int J Prosthodont , vol.16 , pp. 150-156
    • Olsson, K.G.1    Fürst, B.2    Andersson, B.3    Carlsson, G.E.4
  • 11
    • 0026461934 scopus 로고
    • Slip-casting alumina ceramics for crown and bridge restorations
    • Pröbster L, Diehl J. Slip-casting alumina ceramics for crown and bridge restorations. Quintessence Int. 1992;23:25-31.
    • (1992) Quintessence Int , vol.23 , pp. 25-31
    • Pröbster, L.1    Diehl, J.2
  • 12
    • 0026888605 scopus 로고
    • Alternative crown systems. Is the metal-ceramic crown always the restoration of choice
    • Wall JG, Cipra DL. Alternative crown systems. Is the metal-ceramic crown always the restoration of choice. Dent Clin North Am. 1992;36:765-782.
    • (1992) Dent Clin North Am , vol.36 , pp. 765-782
    • Wall, J.G.1    Cipra, D.L.2
  • 13
    • 0029294815 scopus 로고
    • Relative flexural strength of six new ceramic materials
    • Seghi RR, Sorensen JA. Relative flexural strength of six new ceramic materials. Int J Prosthodont. 1995;8:239-246
    • (1995) Int J Prosthodont , vol.8 , pp. 239-246
    • Seghi, R.R.1    Sorensen, J.A.2
  • 16
    • 0032040119 scopus 로고    scopus 로고
    • Meta-analysis of fixed partial denture survival: Prostheses and abutments
    • Scurria MS, Bader JD, Shugars DA. Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent. 1998;79:459-464.
    • (1998) J Prosthet Dent , vol.79 , pp. 459-464
    • Scurria, M.S.1    Bader, J.D.2    Shugars, D.A.3
  • 17
    • 0034157359 scopus 로고    scopus 로고
    • Bond strength of luting cements to zirconium oxide ceramics
    • Dérand P, Dérand T. Bond strength of luting cements to zirconium oxide ceramics. Int J Prosthodont. 2000;13:131-135.
    • (2000) Int J Prosthodont , vol.13 , pp. 131-135
    • Dérand, P.1    Dérand, T.2
  • 18
    • 0035351260 scopus 로고    scopus 로고
    • Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study
    • Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001;14:231-238.
    • (2001) Int J Prosthodont , vol.14 , pp. 231-238
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Augthun, M.4    Spiekermann, H.5
  • 19
    • 0842290999 scopus 로고    scopus 로고
    • Clinical application of the DCS Precident CAD/CAM System
    • Maeda Y. Clinical application of the DCS Precident CAD/CAM System. QDT Yearbook 1996;19:9-20.
    • (1996) QDT Yearbook , vol.19 , pp. 9-20
    • Maeda, Y.1
  • 20
    • 0035495965 scopus 로고    scopus 로고
    • Computer-assisted generation of all-ceramic crowns and fixed partial dentures
    • Besimo CE, Spielmann HP, Rohner HP. Computer-assisted generation of all-ceramic crowns and fixed partial dentures. Int J Comput Dent. 2001;4:243-62.
    • (2001) Int J Comput Dent , vol.4 , pp. 243-262
    • Besimo, C.E.1    Spielmann, H.P.2    Rohner, H.P.3
  • 22
    • 14844351504 scopus 로고    scopus 로고
    • Longevity and Complications of FPDs
    • ED: Karlsson S, Nilner K, Dahl BL. Förlagshuset Gothia
    • Öwall B, Bergman B. Longevity and Complications of FPDs. In: Fixed prosthodontics, the Scandinavian approach. ED: Karlsson S, Nilner K, Dahl BL. Förlagshuset Gothia 2000;290-311.
    • (2000) Fixed Prosthodontics, the Scandinavian Approach , pp. 290-311
    • Öwall, B.1    Bergman, B.2
  • 24
    • 14844356826 scopus 로고
    • Analysis of stress in the porcelain crown, Thesis
    • Academic dissertation
    • Dérand T. Analysis of stress in the porcelain crown, Thesis. Odonol Revy. 1975;25:(supplement 27), Academic dissertation.
    • (1975) Odonol Revy , vol.25 , Issue.27 SUPPL.
    • Dérand, T.1
  • 25
    • 0023462077 scopus 로고
    • Relationship between compressive strength and cervical shaping of the all-ceramic Cerestore crown
    • Sjögren G, Bergman M. Relationship between compressive strength and cervical shaping of the all-ceramic Cerestore crown. Swed Dent J. 1987;11:147-152.
    • (1987) Swed Dent J , vol.11 , pp. 147-152
    • Sjögren, G.1    Bergman, M.2
  • 26
    • 0034575079 scopus 로고    scopus 로고
    • Fracture strength of In-Ceram all-ceramic bridges in relation to cervical shape and try in procedure. An In-vitro study
    • Vult von Steyern P, Al-Ansari A, White K, Nilner K, Dérand T. Fracture strength of In-Ceram all-ceramic bridges in relation to cervical shape and try in procedure. An In-vitro study. Eur J Prosthodont Rest Dent. 2000;4:153-158.
    • (2000) Eur J Prosthodont Rest Dent , vol.4 , pp. 153-158
    • Von Vult Steyern, P.1    Al-Ansari, A.2    White, K.3    Nilner, K.4    Dérand, T.5
  • 27
    • 0141516401 scopus 로고    scopus 로고
    • Influence of Margin Design and Taper Abutment Angle on a Restored Crown of a First Premolar Using Finite Element Analysis
    • Proos KA, Swain MV, Ironside J, Steven GP. Influence of Margin Design and Taper Abutment Angle on a Restored Crown of a First Premolar Using Finite Element Analysis. Int J Prosthodont. 2003;16:442-449.
    • (2003) Int J Prosthodont , vol.16 , pp. 442-449
    • Proos, K.A.1    Swain, M.V.2    Ironside, J.3    Steven, G.P.4
  • 30
    • 0141656436 scopus 로고
    • Designing high strength ceramic crowns and bridges
    • McLean JW. Designing high strength ceramic crowns and bridges. Excellence 1993;15-18.
    • (1993) Excellence , pp. 15-18
    • McLean, J.W.1
  • 31
    • 0025377235 scopus 로고
    • Metallfreie Brucken fur den Seitenzahnbereich
    • Kappert HF, Knode H, Manzotti L. Metallfreie Brucken fur den Seitenzahnbereich. Dent Labor. 1990;38:177-182.
    • (1990) Dent Labor , vol.38 , pp. 177-182
    • Kappert, H.F.1    Knode, H.2    Manzotti, L.3
  • 32
    • 0032018397 scopus 로고    scopus 로고
    • All ceramic alternative to conventional metal-ceramic restorations
    • McLaren EA. All ceramic alternative to conventional metal-ceramic restorations. Compend Contin Educ Dent. 1998; 3:307-325.
    • (1998) Compend Contin Educ Dent , vol.3 , pp. 307-325
    • McLaren, E.A.1
  • 33
    • 14844363814 scopus 로고    scopus 로고
    • Posterior all-ceramic bridgework. Assessment of fracture load and reliability of materials
    • Filser F, Lüthy H, Kocher P, Schärer P, Gauckler LJ. Posterior all-ceramic bridgework. Assessment of fracture load and reliability of materials. QJDT. 2003;1:28-41.
    • (2003) QJDT , vol.1 , pp. 28-41
    • Filser, F.1    Lüthy, H.2    Kocher, P.3    Schärer, P.4    Gauckler, L.J.5
  • 36
    • 0032040119 scopus 로고    scopus 로고
    • Meta-analysis of fixed partial denture survival: Prostheses and abutments
    • Scurria MS, Bader JD, Shugars DA. Meta-analysis of fixed partial denture survival: Prostheses and abutments. J of Prosthet Dent. 1998;79:459-467.
    • (1998) J of Prosthet Dent , vol.79 , pp. 459-467
    • Scurria, M.S.1    Bader, J.D.2    Shugars, D.A.3
  • 37
    • 0038618760 scopus 로고    scopus 로고
    • CAD/CAM systems, materials, and clinical guidelines for all-ceramic crowns and fixed partial denture
    • McLaren EA, Terry DA. CAD/CAM systems, materials, and clinical guidelines for all-ceramic crowns and fixed partial denture. Compend Contin Educ Dent.. 2002;7:637-653.
    • (2002) Compend Contin Educ Dent , vol.7 , pp. 637-653
    • McLaren, E.A.1    Terry, D.A.2
  • 39
    • 0029318343 scopus 로고
    • Failure of all-ceramic fixed partial dentures in vitro and in vivo: Analysis and modelling
    • Kelly JR, Tesk A, Sorensen JA. Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modelling. J Dent Res. 1995;74:1253-1258.
    • (1995) J Dent Res , vol.74 , pp. 1253-1258
    • Kelly, J.R.1    Tesk, A.2    Sorensen, J.A.3
  • 40
    • 0021499999 scopus 로고
    • Structural ceramics: A question of fabrication reliability
    • Lange FF. Structural ceramics: a question of fabrication reliability. J Mater Eng Sys. 1984;6:107-113.
    • (1984) J Mater Eng Sys , vol.6 , pp. 107-113
    • Lange, F.F.1
  • 41
    • 14844362821 scopus 로고    scopus 로고
    • Academy of dental materials. Proceedings of conference on clinical appropriate alternatives to amalgam: Biophysical factors in restorative decision-making
    • Kappert HF. Academy of dental materials. Proceedings of conference on clinical appropriate alternatives to amalgam: biophysical factors in restorative decision-making. Transactions. 1996;9:180-198.
    • (1996) Transactions , vol.9 , pp. 180-198
    • Kappert, H.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.