메뉴 건너뛰기




Volumn 37, Issue 7, 2012, Pages 553-562

Identification of biomechanical properties of the cornea: The ocular response analyzer

Author keywords

Biomechanics; Cornea; Corneal hysteresis (CH); Corneal resistance factor (CRF); Glaucoma; Ocular Response Analyzer (ORA)

Indexed keywords

AGE; ANALYZER; BIOMECHANICS; CATARACT EXTRACTION; CENTRAL CORNEAL THICKNESS; CIRCADIAN RHYTHM; CORNEA; CORNEA DYSTROPHY; CORNEA EDEMA; CORNEAL COLLAGEN CROSSLINKING; CORNEAL HYSTERESIS; CORNEAL RESISTANT FACTOR; CORNEAL SWELLING; CROSS LINKING; DIABETES MELLITUS; GEOMETRY; GLAUCOMA; HUMAN; INTRAOCULAR HYPERTENSION; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOMILEUSIS; KERATOPATHY; MARFAN SYNDROME; MEASUREMENT; MUCOPOLYSACCHARIDOSIS; MYOPIA; OCULAR RESPONSE ANALYZER; PRIORITY JOURNAL; REFRACTIVE SURGERY; REPRODUCIBILITY; SHEAR STRESS; SHORT SURVEY; SWELLING; TEAR FILM; THICKNESS; TOPICAL ANESTHESIA; VISCOELASTICITY; VITRECTOMY;

EID: 84862183066     PISSN: 02713683     EISSN: 14602202     Source Type: Journal    
DOI: 10.3109/02713683.2012.669007     Document Type: Short Survey
Times cited : (188)

References (115)
  • 1
    • 37349045954 scopus 로고    scopus 로고
    • Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure
    • DOI 10.1097/IJG.0b013e3180640f40, PII 0006119820071000000001
    • Broman AT, Congdon NG, Bandeen-Roche K, Quigley HA. Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma. 2007;16:581-588. (Pubitemid 350307608)
    • (2007) Journal of Glaucoma , vol.16 , Issue.7 , pp. 581-588
    • Broman, A.T.1    Congdon, N.G.2    Bandeen-Roche, K.3    Quigley, H.A.4
  • 2
    • 79955757915 scopus 로고    scopus 로고
    • Risk factors for visual field progression in treated glaucoma
    • De Moraes CG, Juthani VJ, Liebmann JM et al. Risk factors for visual field progression in treated glaucoma. Arch Ophthalmol. 2011;129:562-568.
    • (2011) Arch Ophthalmol , vol.129 , pp. 562-568
    • De Moraes, C.G.1    Juthani, V.J.2    Liebmann, J.M.3
  • 3
    • 33751009098 scopus 로고    scopus 로고
    • Relationship between central corneal thickness and changes of optic nerve head topography and blood flow after intraocular pressure reduction in open-angle glaucoma and ocular hypertension
    • DOI 10.1001/archopht.124.11.1568
    • Lesk MR, Hafez AS, Descovich D. Relationship between central corneal thickness and changes of optic nerve head topography and blood flow after intraocular pressure reduction in open-angle glaucoma and ocular hypertension. Arch Ophthalmol. 2006;124:1568-1572. (Pubitemid 44748730)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.11 , pp. 1568-1572
    • Lesk, M.R.1    Hafez, A.S.2    Descovich, D.3
  • 4
    • 59449089967 scopus 로고    scopus 로고
    • Numerical study of the effect of corneal layered structure on ocular biomechanics
    • Elsheikh A, Ross S, Alhasso D, Rama P. Numerical study of the effect of corneal layered structure on ocular biomechanics. Curr Eye Res. 2009;34:26-35.
    • (2009) Curr Eye Res , vol.34 , pp. 26-35
    • Elsheikh, A.1    Ross, S.2    Alhasso, D.3    Rama, P.4
  • 5
    • 0141707873 scopus 로고    scopus 로고
    • Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking
    • DOI 10.1016/S0886-3350(03)00407-3
    • Wollensak G, Spoerl E, Seiler T. Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking. J Cataract Refract Surg. 2003;29:1780-1785. (Pubitemid 37210617)
    • (2003) Journal of Cataract and Refractive Surgery , vol.29 , Issue.9 , pp. 1780-1785
    • Wollensak, G.1    Spoerl, E.2    Seiler, T.3
  • 6
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • DOI 10.1016/j.jcrs.2004.10.044
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156-162. (Pubitemid 40260703)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.1 , pp. 156-162
    • Luce, D.A.1
  • 7
    • 70349767174 scopus 로고    scopus 로고
    • Assessment of the ocular response analyzer as a tool for intraocular pressure measurement
    • Elsheikh A, Alhasso D, Kotecha A, Garway-Heath D. Assessment of the ocular response analyzer as a tool for intraocular pressure measurement. J Biomech Eng. 2009;131:081010.
    • (2009) J Biomech Eng , vol.131 , pp. 081010
    • Elsheikh, A.1    Alhasso, D.2    Kotecha, A.3    Garway-Heath, D.4
  • 9
    • 79960176461 scopus 로고    scopus 로고
    • Ocular biomechanics: Measurement parameters and terminology
    • Reinstein DZ, Gobbe M, Archer TJ. Ocular biomechanics: measurement parameters and terminology. J Refract Surg. 2011;27:396-397.
    • (2011) J Refract Surg , vol.27 , pp. 396-397
    • Reinstein, D.Z.1    Gobbe, M.2    Archer, T.J.3
  • 10
    • 34548027735 scopus 로고    scopus 로고
    • Hysteresis: New mechanospeak for the ophthalmologist
    • Dupps WJ Jr. Hysteresis: new mechanospeak for the ophthalmologist. J Cataract Refract Surg. 2007;33:1499-1501.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1499-1501
    • Dupps Jr., W.J.1
  • 11
    • 79955976348 scopus 로고    scopus 로고
    • A clinical description of Ocular Response Analyzer measurements
    • Lau W, Pye D. A clinical description of Ocular Response Analyzer measurements. Invest Ophthalmol Vis Sci. 2011;52:2911-2916.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 2911-2916
    • Lau, W.1    Pye, D.2
  • 12
    • 53149152237 scopus 로고    scopus 로고
    • A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis
    • Glass DH, Roberts CJ, Litsky AS, Weber PA. A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. Invest Ophthalmol Vis Sci. 2008;49:3919-3926.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3919-3926
    • Glass, D.H.1    Roberts, C.J.2    Litsky, A.S.3    Weber, P.A.4
  • 14
    • 77956662753 scopus 로고    scopus 로고
    • Experimental measurements and predictive modelling of bending behaviour for viscous unidirectional composite materials
    • Wang J, Long A, Clifford M. Experimental measurements and predictive modelling of bending behaviour for viscous unidirectional composite materials. Int J Material Forming. 2010;3:1253-1266.
    • (2010) Int J Material Forming , vol.3 , pp. 1253-1266
    • Wang, J.1    Long, A.2    Clifford, M.3
  • 15
    • 0344514921 scopus 로고    scopus 로고
    • Viscoelasticity of biopolymer networks and statistical mechanics of semiflexible polymers
    • Frey E, Kroy K, Wilhelm J. Viscoelasticity of biopolymer networks and statistical mechanics of semiflexible polymers. Advances in Structural Biology. 1999;5:135-168.
    • (1999) Advances in Structural Biology , vol.5 , pp. 135-168
    • Frey, E.1    Kroy, K.2    Wilhelm, J.3
  • 16
    • 0035946621 scopus 로고    scopus 로고
    • Bending and stretching of thin viscous sheets
    • Ribe NM. Bending and stretching of thin viscous sheets. J Fluid Mech. 2001;433:135-160. (Pubitemid 32406532)
    • (2001) Journal of Fluid Mechanics , vol.433 , pp. 135-160
    • Ribe, N.M.1
  • 17
    • 11144222596 scopus 로고    scopus 로고
    • Lamellar orientation in human cornea in relation to mechanical properties
    • DOI 10.1016/j.jsb.2004.08.009, PII S1047847704001704
    • Boote C, Dennis S, Huang Y, Quantock AJ, Meek KM. Lamellar orientation in human cornea in relation to mechanical properties. J Struct Biol. 2005;149:1-6. (Pubitemid 40051396)
    • (2005) Journal of Structural Biology , vol.149 , Issue.1 , pp. 1-6
    • Boote, C.1    Dennis, S.2    Huang, Y.3    Quantock, A.J.4    Meek, K.M.5
  • 18
    • 47849083274 scopus 로고    scopus 로고
    • Plasma viscosity: A forgotten variable
    • DOI 10.3233/CH-2008-1088, Selected Proceedings of the 14th European Conference for Clinical Hemorheology and Microcirculation, Dresden, Germany, June 27-30, 2007
    • Késmárky G, Kenyeres P, Rábai M, Tóth K. Plasma viscosity: a forgotten variable. Clin Hemorheol Microcirc. 2008;39:243-246. (Pubitemid 352040003)
    • (2008) Clinical Hemorheology and Microcirculation , vol.39 , Issue.1-4 , pp. 243-246
    • Kesmarky, G.1    Kenyeres, P.2    Rabai, M.3    Toth, K.4
  • 19
    • 0015589939 scopus 로고
    • The role of the fibrous components and ground substance in the mechanical properties of biological tissues: A preliminary investigation
    • Minns RJ, Soden PD, Jackson DS. The role of the fibrous components and ground substance in the mechanical properties of biological tissues: a preliminary investigation. J Biomech. 1973;6:153-165.
    • (1973) J Biomech , vol.6 , pp. 153-165
    • Minns, R.J.1    Soden, P.D.2    Jackson, D.S.3
  • 20
    • 79960697124 scopus 로고    scopus 로고
    • Effects of Eye Rubbing and Breath Holding on Corneal Biomechanical Properties and Intraocular Pressure
    • Liu WC, Lee SM, Graham AD, Lin MC. Effects of Eye Rubbing and Breath Holding on Corneal Biomechanical Properties and Intraocular Pressure. Cornea. 2011;30:855-860.
    • (2011) Cornea , vol.30 , pp. 855-860
    • Liu, W.C.1    Lee, S.M.2    Graham, A.D.3    Lin, M.C.4
  • 21
    • 79960201170 scopus 로고    scopus 로고
    • Detection of biomechanical changes after corneal cross-linking using Ocular Response Analyzer software
    • Spoerl E, Terai N, Scholz F, Raiskup F, Pillunat LE. Detection of biomechanical changes after corneal cross-linking using Ocular Response Analyzer software. J Refract Surg. 2011;27:452-457.
    • (2011) J Refract Surg , vol.27 , pp. 452-457
    • Spoerl, E.1    Terai, N.2    Scholz, F.3    Raiskup, F.4    Pillunat, L.E.5
  • 22
    • 47649131247 scopus 로고    scopus 로고
    • Repeatability of intraocular pressure and corneal biomechanical properties measurements by the ocular response analyser
    • DOI 10.1055/s-2008-1027256
    • Kynigopoulos M, Schlote T, Kotecha A, Tzamalis A, Pajic B, Haefliger I. Repeatability of intraocular pressure and corneal biomechanical properties measurements by the ocular response analyser. Klin Monbl Augenheilkd. 2008;225:357-360. (Pubitemid 352016458)
    • (2008) Klinische Monatsblatter fur Augenheilkunde , vol.225 , Issue.5 , pp. 357-360
    • Kynigopoulos, M.1    Schlote, T.2    Kotecha, A.3    Tzamalis, A.4    Pajic, B.5    Haefliger, I.6
  • 24
    • 67949097335 scopus 로고    scopus 로고
    • Biomechanical condition of the cornea as a new indicator for pathological and structural changes
    • Spörl E, Terai N, Haustein M, Böhm AG, Raiskup-Wolf F, Pillunat LE. [Biomechanical condition of the cornea as a new indicator for pathological and structural changes]. Ophthalmologe. 2009;106:512-520.
    • (2009) Ophthalmologe , vol.106 , pp. 512-520
    • Spörl, E.1    Terai, N.2    Haustein, M.3    Böhm, A.G.4    Raiskup-Wolf, F.5    Pillunat, L.E.6
  • 25
    • 77950655570 scopus 로고    scopus 로고
    • The usefulness of waveform score from the Ocular Response Analyzer
    • Lam A, Chen D, Tse J. The usefulness of waveform score from the Ocular Response Analyzer. Optomet Vis Sci. 2010;87:195-199.
    • (2010) Optomet Vis Sci , vol.87 , pp. 195-199
    • Lam, A.1    Chen, D.2    Tse, J.3
  • 26
    • 0018903467 scopus 로고
    • The non-contact tonometer. Its value and limitations
    • DOI 10.1016/0039-6257(80)90042-9
    • Shields MB. The non-contact tonometer. Its value and limitations. Surv Ophthalmol. 1980;24:211-219. (Pubitemid 10161236)
    • (1980) Survey of Ophthalmology , vol.24 , Issue.4 , pp. 211-219
    • Shields, M.B.1
  • 27
    • 33750598651 scopus 로고    scopus 로고
    • Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement
    • DOI 10.1167/iovs.06-0507
    • Kida T, Liu JH, Weinreb RN. Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement. Invest Ophthalmol Vis Sci. 2006;47:4422-4426. (Pubitemid 46579368)
    • (2006) Investigative Ophthalmology and Visual Science , vol.47 , Issue.10 , pp. 4422-4426
    • Kida, T.1    Liu, J.H.K.2    Weinreb, R.N.3
  • 28
    • 33644802292 scopus 로고    scopus 로고
    • Diurnal variation of ocular hysteresis in normal subjects: Relevance in clinical context
    • DOI 10.1111/j.1442-9071.2006.01185.x
    • Laiquzzaman M, Bhojwani R, Cunliffe I, Shah S. Diurnal variation of ocular hysteresis in normal subjects: relevance in clinical context. Clin Experiment Ophthalmol. 2006;34:114-118. (Pubitemid 43348983)
    • (2006) Clinical and Experimental Ophthalmology , vol.34 , Issue.2 , pp. 114-118
    • Laiquzzaman, M.1    Bhojwani, R.2    Cunliffe, I.3    Shah, S.4
  • 29
    • 70349244879 scopus 로고    scopus 로고
    • The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis
    • Kotecha A, Crabb DP, Spratt A, Garway-Heath DF. The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci. 2009;50:4229-4236.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 4229-4236
    • Kotecha, A.1    Crabb, D.P.2    Spratt, A.3    Garway-Heath, D.F.4
  • 30
    • 70549096979 scopus 로고    scopus 로고
    • Diurnal variation of corneal biomechanics and intraocular pressure in normal subjects
    • Oncel B, Dinc UA, Gorgun E, Yalvaç BI. Diurnal variation of corneal biomechanics and intraocular pressure in normal subjects. Eur J Ophthalmol. 2009;19:798-803.
    • (2009) Eur J Ophthalmol , vol.19 , pp. 798-803
    • Oncel, B.1    Dinc, U.A.2    Gorgun, E.3    Yalvaç, B.I.4
  • 31
    • 33845227093 scopus 로고    scopus 로고
    • Corneal Hysteresis and Intraocular Pressure Measurement in Children Using the Reichert Ocular Response Analyzer
    • DOI 10.1016/j.ajo.2006.07.058, PII S0002939406009111
    • Kirwan C, O'Keefe M, Lanigan B. Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer. Am J Ophthalmol. 2006;142:990-992. (Pubitemid 44853910)
    • (2006) American Journal of Ophthalmology , vol.142 , Issue.6 , pp. 990-992
    • Kirwan, C.1    O'keefe, M.2    Lanigan, B.3
  • 32
    • 70349744323 scopus 로고    scopus 로고
    • Effect of topical corneal anaesthesia on ocular response analyzer parameters: Pilot study
    • Ehongo A, De Maertelaer V, Pourjavan S. Effect of topical corneal anaesthesia on ocular response analyzer parameters: pilot study. Int Ophthalmol. 2009;29:325-328.
    • (2009) Int Ophthalmol , vol.29 , pp. 325-328
    • Ehongo, A.1    De Maertelaer, V.2    Pourjavan, S.3
  • 35
    • 33947431052 scopus 로고    scopus 로고
    • Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure
    • Lu F, Xu S, Qu J et al. Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure. Am J Ophthalmol. 2007;143:616-622.
    • (2007) Am J Ophthalmol , vol.143 , pp. 616-622
    • Lu, F.1    Xu, S.2    Qu, J.3
  • 36
    • 33750995542 scopus 로고    scopus 로고
    • The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes
    • DOI 10.1016/j.clae.2006.09.006, PII S1367048406001317
    • Shah S, Laiquzzaman M, Cunliffe I, Mantry S. The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes. Cont Lens Anterior Eye. 2006;29:257-262. (Pubitemid 44743122)
    • (2006) Contact Lens and Anterior Eye , vol.29 , Issue.5 , pp. 257-262
    • Shah, S.1    Laiquzzaman, M.2    Cunliffe, I.3    Mantry, S.4
  • 37
    • 50249182271 scopus 로고    scopus 로고
    • The heritability of corneal hysteresis and ocular pulse amplitude: A twin study
    • Carbonaro F, Andrew T, Mackey DA, Spector TD, Hammond CJ. The heritability of corneal hysteresis and ocular pulse amplitude: a twin study. Ophthalmology. 2008;115:1545-1549.
    • (2008) Ophthalmology , vol.115 , pp. 1545-1549
    • Carbonaro, F.1    Andrew, T.2    Mackey, D.A.3    Spector, T.D.4    Hammond, C.J.5
  • 39
    • 79955679851 scopus 로고    scopus 로고
    • Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer
    • Detry-Morel M, Jamart J, Pourjavan S. Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer. Eur J Ophthalmol. 2011;21:138-148.
    • (2011) Eur J Ophthalmol , vol.21 , pp. 138-148
    • Detry-Morel, M.1    Jamart, J.2    Pourjavan, S.3
  • 40
    • 73349112216 scopus 로고    scopus 로고
    • Association between corneal hysteresis and central corneal thickness in glaucomatous and non-glaucomatous eyes
    • Mangouritsas G, Morphis G, Mourtzoukos S, Feretis E. Association between corneal hysteresis and central corneal thickness in glaucomatous and non-glaucomatous eyes. Acta Ophthalmol. 2009;87:901-905.
    • (2009) Acta Ophthalmol , vol.87 , pp. 901-905
    • Mangouritsas, G.1    Morphis, G.2    Mourtzoukos, S.3    Feretis, E.4
  • 41
    • 73949114592 scopus 로고    scopus 로고
    • Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry
    • Oncel B, Dinc U, Orge F, Yalvac B. Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry. Eur J Ophthalmol. 2009;19:936-941.
    • (2009) Eur J Ophthalmol , vol.19 , pp. 936-941
    • Oncel, B.1    Dinc, U.2    Orge, F.3    Yalvac, B.4
  • 42
    • 76149125127 scopus 로고    scopus 로고
    • Corneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes
    • Abitbol O, Bouden J, Doan S, Hoang-Xuan T, Gatinel D. Corneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes. Acta Ophthalmol. 2010;88:116-119.
    • (2010) Acta Ophthalmol , vol.88 , pp. 116-119
    • Abitbol, O.1    Bouden, J.2    Doan, S.3    Hoang-Xuan, T.4    Gatinel, D.5
  • 43
    • 79960407349 scopus 로고    scopus 로고
    • Comparison of factors that influence the measurement of corneal hysteresis in vivo and in vitro
    • Alhamad TA, Meek KM. Comparison of factors that influence the measurement of corneal hysteresis in vivo and in vitro. Acta Ophthalmol. 2011;89:e443-e450.
    • (2011) Acta Ophthalmol , vol.89
    • Alhamad, T.A.1    Meek, K.M.2
  • 44
    • 78650459777 scopus 로고    scopus 로고
    • Ocular response analyzer and Goldmann applanation tonometry: A comparative study of findings
    • Bayoumi NH, Bessa AS, El Massry AA. Ocular response analyzer and Goldmann applanation tonometry: a comparative study of findings. J Glaucoma. 2010;19:627-631.
    • (2010) J Glaucoma , vol.19 , pp. 627-631
    • Bayoumi, N.H.1    Bessa, A.S.2    El Massry, A.A.3
  • 45
    • 63349107518 scopus 로고    scopus 로고
    • Measurement of viscoelastic corneal parameters (corneal hysteresis) in patients with primary open angle glaucoma
    • Schroeder B, Hager A, Kutschan A, Wiegand W. [Measurement of viscoelastic corneal parameters (corneal hysteresis) in patients with primary open angle glaucoma]. Ophthalmologe. 2008;105:916-920.
    • (2008) Ophthalmologe , vol.105 , pp. 916-920
    • Schroeder, B.1    Hager, A.2    Kutschan, A.3    Wiegand, W.4
  • 47
    • 84857852477 scopus 로고    scopus 로고
    • Improved Keratoconus Detection by Ocular Response Analyzer Testing after Consideration of Corneal Thickness as a Confounding Factor
    • Galletti JG, Pfortner T, Bonthoux FF. Improved Keratoconus Detection by Ocular Response Analyzer Testing After Consideration of Corneal Thickness as a Confounding Factor. J Refract Surg. 2012;28:1-7.
    • (2012) J Refract Surg , vol.28 , pp. 1-7
    • Galletti, J.G.1    Pfortner, T.2    Bonthoux, F.F.3
  • 48
    • 84862811896 scopus 로고    scopus 로고
    • Correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry
    • Yu AY, Duan SF, Zhao YE et al. Correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry. Br J Ophthalmol. 2011.
    • (2011) Br J Ophthalmol
    • Yu, A.Y.1    Duan, S.F.2    Zhao, Y.E.3
  • 49
    • 79952234796 scopus 로고    scopus 로고
    • Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma
    • Hirneiss C, Neubauer AS, Yu A, Kampik A, Kernt M. Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma. Acta Ophthalmol. 2011;89:e189-e192.
    • (2011) Acta Ophthalmol , vol.89
    • Hirneiss, C.1    Neubauer, A.S.2    Yu, A.3    Kampik, A.4    Kernt, M.5
  • 50
    • 84855368623 scopus 로고    scopus 로고
    • Intraocular pressure and corneal biomechanics in an adult British population: The EPIC-Norfolk eye study
    • Foster PJ, Broadway DC, Garway-Heath DF et al. Intraocular pressure and corneal biomechanics in an adult British population: the EPIC-Norfolk eye study. Invest Ophthalmol Vis Sci. 2011;52:8179-8185.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8179-8185
    • Foster, P.J.1    Broadway, D.C.2    Garway-Heath, D.F.3
  • 51
    • 84857923088 scopus 로고    scopus 로고
    • Assessing corneal hysteresis using the ocular response analyzer
    • McMonnies CW. Assessing corneal hysteresis using the ocular response analyzer. Optom Vis Sci. 2012;89:E343-E349.
    • (2012) Optom Vis Sci , vol.89
    • McMonnies, C.W.1
  • 52
    • 51649083685 scopus 로고    scopus 로고
    • Biomechanical properties of the cornea in high myopia
    • Shen M, Fan F, Xue A, Wang J, Zhou X, Lu F. Biomechanical properties of the cornea in high myopia. Vision Res. 2008;48:2167-2171.
    • (2008) Vision Res , vol.48 , pp. 2167-2171
    • Shen, M.1    Fan, F.2    Xue, A.3    Wang, J.4    Zhou, X.5    Lu, F.6
  • 53
    • 47749089022 scopus 로고    scopus 로고
    • Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma
    • Ang GS, Bochmann F, Townend J, Azuara-Blanco A. Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma. J Glaucoma. 2008;17:259-262.
    • (2008) J Glaucoma , vol.17 , pp. 259-262
    • Ang, G.S.1    Bochmann, F.2    Townend, J.3    Azuara-Blanco, A.4
  • 54
    • 34548534392 scopus 로고    scopus 로고
    • Effect of ocular massage on intraocular pressure and corneal biomechanics [7]
    • DOI 10.1038/sj.eye.6702928, PII 6702928
    • Lam AK, Chen D. Effect of ocular massage on intraocular pressure and corneal biomechanics. Eye (Lond). 2007;21:1245-1246. (Pubitemid 47382161)
    • (2007) Eye , vol.21 , Issue.9 , pp. 1245-1246
    • Lam, A.K.C.1    Chen, D.2
  • 55
    • 77951493830 scopus 로고    scopus 로고
    • Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
    • Iordanidou V, Hamard P, Gendron G, Labbé A, Raphael M, Baudouin C. Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy. J Glaucoma. 2010;19:252-256.
    • (2010) J Glaucoma , vol.19 , pp. 252-256
    • Iordanidou, V.1    Hamard, P.2    Gendron, G.3    Labbé, A.4    Raphael, M.5    Baudouin, C.6
  • 56
    • 77957299750 scopus 로고    scopus 로고
    • Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer
    • Shin JY, Choi JS, Oh JY, Kim MK, Lee JH, Wee WR. Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer. Korean J Ophthalmol. 2010;24:139-142.
    • (2010) Korean J Ophthalmol , vol.24 , pp. 139-142
    • Shin, J.Y.1    Choi, J.S.2    Oh, J.Y.3    Kim, M.K.4    Lee, J.H.5    Wee, W.R.6
  • 58
    • 34248347895 scopus 로고    scopus 로고
    • Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    • DOI 10.1167/iovs.06-0557
    • Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-Heath DF. Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest Ophthalmol Vis Sci. 2006;47:5337-5347. (Pubitemid 46729154)
    • (2006) Investigative Ophthalmology and Visual Science , vol.47 , Issue.12 , pp. 5337-5347
    • Kotecha, A.1    Elsheikh, A.2    Roberts, C.R.3    Zhu, H.4    Garway-Heath, D.F.5
  • 59
    • 34547105084 scopus 로고    scopus 로고
    • Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes
    • DOI 10.1016/j.jcrs.2007.04.021, PII S0886335007008279
    • Ortiz D, Piñero D, Shabayek MH, Arnalich-Montiel F, AlióJL. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg. 2007;33:1371-1375. (Pubitemid 47096684)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.8 , pp. 1371-1375
    • Ortiz, D.1    Pinero, D.2    Shabayek, M.H.3    Arnalich-Montiel, F.4    Alio, J.L.5
  • 60
    • 51649118534 scopus 로고    scopus 로고
    • Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure
    • Kida T, Liu JH, Weinreb RN. Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure. Am J Ophthalmol. 2008;146:567-572.
    • (2008) Am J Ophthalmol , vol.146 , pp. 567-572
    • Kida, T.1    Liu, J.H.2    Weinreb, R.N.3
  • 61
    • 73149112202 scopus 로고    scopus 로고
    • Effect of aging on corneal biomechanical parameters using the ocular response analyzer
    • Kamiya K, Shimizu K, Ohmoto F. Effect of aging on corneal biomechanical parameters using the ocular response analyzer. J Refract Surg. 2009;25:888-893.
    • (2009) J Refract Surg , vol.25 , pp. 888-893
    • Kamiya, K.1    Shimizu, K.2    Ohmoto, F.3
  • 62
    • 34247341648 scopus 로고    scopus 로고
    • Central Corneal Thickness of Korean Patients with Glaucoma
    • DOI 10.1016/j.ophtha.2006.09.036, PII S0161642006014837
    • Lee ES, Kim CY, Ha SJ, Seong GJ, Hong YJ. Central corneal thickness of Korean patients with glaucoma. Ophthalmology. 2007;114:927-930. (Pubitemid 46635839)
    • (2007) Ophthalmology , vol.114 , Issue.5 , pp. 927-930
    • Lee, E.S.1    Kim, C.Y.2    Ha, S.J.3    Seong, G.J.4    Hong, Y.J.5
  • 63
    • 70349244877 scopus 로고    scopus 로고
    • The relationship of intraocular pressure with age, systolic blood pressure, and central corneal thickness in an Asian population
    • SiMES Study Group
    • Wong TT, Wong TY, Foster PJ, Crowston JG, Fong CW, Aung T; SiMES Study Group. The relationship of intraocular pressure with age, systolic blood pressure, and central corneal thickness in an Asian population. Invest Ophthalmol Vis Sci. 2009;50:4097-4102.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 4097-4102
    • Wong, T.T.1    Wong, T.Y.2    Foster, P.J.3    Crowston, J.G.4    Fong, C.W.5    Aung, T.6
  • 64
    • 59849103667 scopus 로고    scopus 로고
    • Diurnal variation of ocular hysteresis, corneal thickness, and intraocular pressure
    • Shen M, Wang J, Qu J et al. Diurnal variation of ocular hysteresis, corneal thickness, and intraocular pressure. Optom Vis Sci. 2008;85:1185-1192.
    • (2008) Optom Vis Sci , vol.85 , pp. 1185-1192
    • Shen, M.1    Wang, J.2    Qu, J.3
  • 65
    • 69549114451 scopus 로고    scopus 로고
    • Changes of extracellular matrix of the cornea in diabetes mellitus
    • Hager A, Wegscheider K, Wiegand W. Changes of extracellular matrix of the cornea in diabetes mellitus. Graefes Arch Clin Exp Ophthalmol. 2009;247:1369-1374.
    • (2009) Graefes Arch Clin Exp Ophthalmol , vol.247 , pp. 1369-1374
    • Hager, A.1    Wegscheider, K.2    Wiegand, W.3
  • 66
    • 53149120317 scopus 로고    scopus 로고
    • Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children
    • Lim L, Gazzard G, Chan YH et al. Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children. Invest Ophthalmol Vis Sci. 2008;49:3852-3857.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3852-3857
    • Lim, L.1    Gazzard, G.2    Chan, Y.H.3
  • 67
    • 66449107525 scopus 로고    scopus 로고
    • A pilot study on the corneal biomechanical changes in short-term orthokeratology
    • Chen D, Lam AK, Cho P. A pilot study on the corneal biomechanical changes in short-term orthokeratology. Ophthalmic Physiol Opt. 2009;29:464-471.
    • (2009) Ophthalmic Physiol Opt , vol.29 , pp. 464-471
    • Chen, D.1    Lam, A.K.2    Cho, P.3
  • 69
    • 43049162800 scopus 로고    scopus 로고
    • Corneal hysteresis and axial length among Chinese secondary school children: The Xichang Pediatric Refractive Error Study (X-PRES) report no. 4
    • Song Y, Congdon N, Li L et al. Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) report no. 4. Am J Ophthalmol. 2008;145:819-826.
    • (2008) Am J Ophthalmol , vol.145 , pp. 819-826
    • Song, Y.1    Congdon, N.2    Li, L.3
  • 70
    • 55849111550 scopus 로고    scopus 로고
    • Corneal biomechanical measurements before and after laser in situ keratomileusis
    • Chen MC, Lee N, Bourla N, Hamilton DR. Corneal biomechanical measurements before and after laser in situ keratomileusis. J Cataract Refract Surg. 2008;34:1886-1891.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1886-1891
    • Chen, M.C.1    Lee, N.2    Bourla, N.3    Hamilton, D.R.4
  • 71
    • 33845499055 scopus 로고    scopus 로고
    • Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
    • Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143:39-47.
    • (2007) Am J Ophthalmol , vol.143 , pp. 39-47
    • Pepose, J.S.1    Feigenbaum, S.K.2    Qazi, M.A.3    Sanderson, J.P.4    Roberts, C.J.5
  • 73
    • 67349090014 scopus 로고    scopus 로고
    • Comparison of corneal biomechanics in pre and post-refractive surgery and keratoconic eyes by Ocular Response Analyser
    • quiz 151
    • Shah S, Laiquzzaman M. Comparison of corneal biomechanics in pre and post-refractive surgery and keratoconic eyes by Ocular Response Analyser. Cont Lens Anterior Eye. 2009;32:129-132; quiz 151.
    • (2009) Cont Lens Anterior Eye , vol.32 , pp. 129-132
    • Shah, S.1    Laiquzzaman, M.2
  • 74
    • 67349170031 scopus 로고    scopus 로고
    • The use of the Ocular Response Analyser to determine corneal hysteresis in eyes before and after excimer laser refractive surgery
    • Shah S, Laiquzzaman M, Yeung I, Pan X, Roberts C. The use of the Ocular Response Analyser to determine corneal hysteresis in eyes before and after excimer laser refractive surgery. Cont Lens Anterior Eye. 2009;32:123-8.
    • (2009) Cont Lens Anterior Eye , vol.32 , pp. 123-128
    • Shah, S.1    Laiquzzaman, M.2    Yeung, I.3    Pan, X.4    Roberts, C.5
  • 75
    • 67651205120 scopus 로고    scopus 로고
    • Time course of corneal biomechanical parameters after laser in situ keratomileusis
    • Kamiya K, Shimizu K, Ohmoto F. Time course of corneal biomechanical parameters after laser in situ keratomileusis. Ophthalmic Res. 2009;42:167-171.
    • (2009) Ophthalmic Res , vol.42 , pp. 167-171
    • Kamiya, K.1    Shimizu, K.2    Ohmoto, F.3
  • 78
    • 70349582568 scopus 로고    scopus 로고
    • Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus
    • Dauwe C, Touboul D, Roberts CJ et al. Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus. J Cataract Refract Surg. 2009;35:1761-1767.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1761-1767
    • Dauwe, C.1    Touboul, D.2    Roberts, C.J.3
  • 79
    • 79956353546 scopus 로고    scopus 로고
    • Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus
    • Mikielewicz M, Kotliar K, Barraquer RI, Michael R. Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus. Br J Ophthalmol. 2011;95:793-798.
    • (2011) Br J Ophthalmol , vol.95 , pp. 793-798
    • Mikielewicz, M.1    Kotliar, K.2    Barraquer, R.I.3    Michael, R.4
  • 80
    • 78149472012 scopus 로고    scopus 로고
    • Comparison of biomechanical parameters in penetrating keratoplasty and normal eyes using the Ocular Response Analyser
    • Laiquzzaman M, Tambe K, Shah S. Comparison of biomechanical parameters in penetrating keratoplasty and normal eyes using the Ocular Response Analyser. Clin Experiment Ophthalmol. 2010;38:758-763.
    • (2010) Clin Experiment Ophthalmol , vol.38 , pp. 758-763
    • Laiquzzaman, M.1    Tambe, K.2    Shah, S.3
  • 81
    • 79954988953 scopus 로고    scopus 로고
    • Graft biomechanical properties after penetrating keratoplasty versus deep anterior lamellar keratoplasty
    • Jafarinasab MR, Feizi S, Javadi MA, Hashemloo A. Graft biomechanical properties after penetrating keratoplasty versus deep anterior lamellar keratoplasty. Curr Eye Res. 2011;36:417-421.
    • (2011) Curr Eye Res , vol.36 , pp. 417-421
    • Jafarinasab, M.R.1    Feizi, S.2    Javadi, M.A.3    Hashemloo, A.4
  • 82
    • 34548022426 scopus 로고    scopus 로고
    • Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes
    • DOI 10.1167/iovs.04-0694
    • Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci. 2007;48:3026-3031. (Pubitemid 351261143)
    • (2007) Investigative Ophthalmology and Visual Science , vol.48 , Issue.7 , pp. 3026-3031
    • Shah, S.1    Laiquzzaman, M.2    Bhojwani, R.3    Mantry, S.4    Cunliffe, I.5
  • 83
    • 77949655586 scopus 로고    scopus 로고
    • Corneal biomechanical metrics and anterior segment parameters in mild keratoconus
    • Fontes BM, Ambrósio R Jr, Jardim D, Velarde GC, Nosé W. Corneal biomechanical metrics and anterior segment parameters in mild keratoconus. Ophthalmology. 2010;117:673-679.
    • (2010) Ophthalmology , vol.117 , pp. 673-679
    • Fontes, B.M.1    Ambrósio Jr., R.2    Jardim, D.3    Velarde, G.C.4    Nosé, W.5
  • 85
    • 79953001274 scopus 로고    scopus 로고
    • Ocular response analyzer measurements in keratoconus with normal central corneal thickness compared with matched normal control eyes
    • Fontes BM, Ambrósio R Jr, Velarde GC, Nosé W. Ocular response analyzer measurements in keratoconus with normal central corneal thickness compared with matched normal control eyes. J Refract Surg. 2011;27:209-215.
    • (2011) J Refract Surg , vol.27 , pp. 209-215
    • Fontes, B.M.1    Ambrósio Jr., R.2    Velarde, G.C.3    Nosé, W.4
  • 89
    • 67949105758 scopus 로고    scopus 로고
    • Comparison of Biomechanical and Topographic Parameters in Normal and Pathologic Corneas
    • Available at
    • Mahmoud AM, Twa M, Qazi M, Pepose J, Roberts C. Comparison of Biomechanical and Topographic Parameters in Normal and Pathologic Corneas. Invest Ophthalmol Vis Sci. 2007;48:E-1843 Available at www.iovs.org.
    • (2007) Invest Ophthalmol Vis Sci , vol.48
    • Mahmoud, A.M.1    Twa, M.2    Qazi, M.3    Pepose, J.4    Roberts, C.5
  • 90
    • 0031941909 scopus 로고    scopus 로고
    • Induction of cross-links in corneal tissue
    • DOI 10.1006/exer.1997.0410
    • Spoerl E, Huhle M, Seiler T. Induction of cross-links in corneal tissue. Exp Eye Res. 1998;66:97-103. (Pubitemid 28070342)
    • (1998) Experimental Eye Research , vol.66 , Issue.1 , pp. 97-103
    • Spoerl, E.1    Huhle, M.2    Seiler, T.3
  • 91
    • 67650571797 scopus 로고    scopus 로고
    • Can we measure corneal biomechanical changes after collagen cross-linking in eyes with keratoconus?-a pilot study
    • Goldich Y, Barkana Y, Morad Y, Hartstein M, Avni I, Zadok D. Can we measure corneal biomechanical changes after collagen cross-linking in eyes with keratoconus?-a pilot study. Cornea. 2009;28:498-502.
    • (2009) Cornea , vol.28 , pp. 498-502
    • Goldich, Y.1    Barkana, Y.2    Morad, Y.3    Hartstein, M.4    Avni, I.5    Zadok, D.6
  • 92
    • 79956363647 scopus 로고    scopus 로고
    • Interlamellar cohesion after corneal crosslinking using riboflavin and ultraviolet A light
    • Wollensak G, Sporl E, Mazzotta C, Kalinski T, Sel S. Interlamellar cohesion after corneal crosslinking using riboflavin and ultraviolet A light. Br J Ophthalmol. 2011;95:876-880.
    • (2011) Br J Ophthalmol , vol.95 , pp. 876-880
    • Wollensak, G.1    Sporl, E.2    Mazzotta, C.3    Kalinski, T.4    Sel, S.5
  • 93
    • 38349018398 scopus 로고    scopus 로고
    • Contact-based stiffness sensing of human eye
    • Kurita Y, Kempf R, Iida Y et al. Contact-based stiffness sensing of human eye. IEEE Trans Biomed Eng. 2008;55:739-745.
    • (2008) IEEE Trans Biomed Eng , vol.55 , pp. 739-745
    • Kurita, Y.1    Kempf, R.2    Iida, Y.3
  • 94
    • 77957668757 scopus 로고    scopus 로고
    • Intra- and postoperative variation in ocular response analyzer parameters in keratoconic eyes after corneal cross-linking
    • Vinciguerra P, Albè E, Mahmoud AM, Trazza S, Hafezi F, Roberts CJ. Intra- and postoperative variation in ocular response analyzer parameters in keratoconic eyes after corneal cross-linking. J Refract Surg. 2010;26:669-676.
    • (2010) J Refract Surg , vol.26 , pp. 669-676
    • Vinciguerra, P.1    Albè, E.2    Mahmoud, A.M.3    Trazza, S.4    Hafezi, F.5    Roberts, C.J.6
  • 96
    • 78049257366 scopus 로고    scopus 로고
    • Corneal biomechanical characteristics in patients with diabetes mellitus
    • Kotecha A, Oddone F, Sinapis C et al. Corneal biomechanical characteristics in patients with diabetes mellitus. J Cataract Refract Surg. 2010;36:1822-1828.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1822-1828
    • Kotecha, A.1    Oddone, F.2    Sinapis, C.3
  • 97
    • 70349572803 scopus 로고    scopus 로고
    • Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements
    • Sahin A, Bayer A, Ozge G, Mumcuoglu T. Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements. Invest Ophthalmol Vis Sci. 2009;50:4597-4604.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 4597-4604
    • Sahin, A.1    Bayer, A.2    Ozge, G.3    Mumcuoglu, T.4
  • 98
    • 0031444902 scopus 로고    scopus 로고
    • Nonenzymatic glycation of cartilage proteoglcans: An in vivo and in vitro study
    • DOI 10.1023/A:1018514727213
    • Pokharna HK, Pottenger LA. Nonenzymatic glycation of cartilage proteoglycans: an in vivo and in vitro study. Glycoconj J. 1997;14:917-923. (Pubitemid 28040012)
    • (1997) Glycoconjugate Journal , vol.14 , Issue.8 , pp. 917-923
    • Pokharna, H.K.1    Pottenger, L.A.2
  • 99
    • 84865699715 scopus 로고    scopus 로고
    • Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure
    • Scheler A, Spoerl E, Boehm A. Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure. Acta Ophthalmologica. 2012.
    • (2012) Acta Ophthalmologica
    • Scheler, A.1    Spoerl, E.2    Boehm, A.3
  • 100
    • 55449090618 scopus 로고    scopus 로고
    • Non-enzymatic glycation of chondrocyte-seeded collagen gels for cartilage tissue engineering
    • Roy R, Boskey AL, Bonassar LJ. Non-enzymatic glycation of chondrocyte-seeded collagen gels for cartilage tissue engineering. J Orthop Res. 2008;26:1434-1439.
    • (2008) J Orthop Res , vol.26 , pp. 1434-1439
    • Roy, R.1    Boskey, A.L.2    Bonassar, L.J.3
  • 102
    • 42149110944 scopus 로고    scopus 로고
    • The effect of cataract and vitreoretinal surgery on central corneal thickness and corneal hysteresis
    • Hager A, Loge K, Kutschan A, Wiegand W. [The effect of cataract and vitreoretinal surgery on central corneal thickness and corneal hysteresis]. Klin Monbl Augenheilkd. 2008;225:207-211.
    • (2008) Klin Monbl Augenheilkd , vol.225 , pp. 207-211
    • Hager, A.1    Loge, K.2    Kutschan, A.3    Wiegand, W.4
  • 103
    • 56249109095 scopus 로고    scopus 로고
    • Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation
    • Kucumen RB, Yenerel NM, Gorgun E et al. Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation. J Cataract Refract Surg. 2008;34:2096-2098.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 2096-2098
    • Kucumen, R.B.1    Yenerel, N.M.2    Gorgun, E.3
  • 104
    • 80155143270 scopus 로고    scopus 로고
    • Corneal hysteresis in mucopolysaccharidosis I and VI
    • Epub ahead of print
    • Fahnehjelm KT, Chen E, Winiarski J. Corneal hysteresis in mucopolysaccharidosis I and VI. Acta Ophthalmol. 2011 Epub ahead of print.
    • (2011) Acta Ophthalmol
    • Fahnehjelm, K.T.1    Chen, E.2    Winiarski, J.3
  • 105
    • 84857062936 scopus 로고    scopus 로고
    • Corneal biomechanical properties and intraocular pressure measurement in Marfan patients
    • Kara N, Bozkurt E, Baz O et al. Corneal biomechanical properties and intraocular pressure measurement in Marfan patients. J Cataract Refract Surg. 2012;38:309-314.
    • (2012) J Cataract Refract Surg , vol.38 , pp. 309-314
    • Kara, N.1    Bozkurt, E.2    Baz, O.3
  • 106
    • 0025109858 scopus 로고
    • Deficient expression of the gene coding for decorin in a lethal form of Marfan syndrome
    • Pulkkinen L, Kainulainen K, Krusius T et al. Deficient expression of the gene coding for decorin in a lethal form of Marfan syndrome. J Biol Chem. 1990;265:17780-17785.
    • (1990) J Biol Chem , vol.265 , pp. 17780-17785
    • Pulkkinen, L.1    Kainulainen, K.2    Krusius, T.3
  • 107
    • 0027052996 scopus 로고
    • Deficiencies of fibrillin and decorin in fibroblast cultures of a patient with neonatal Marfan syndrome
    • Superti-Furga A, Raghunath M, Willems PJ. Deficiencies of fibrillin and decorin in fibroblast cultures of a patient with neonatal Marfan syndrome. J Med Genet. 1992;29:875-878. (Pubitemid 23035211)
    • (1992) Journal of Medical Genetics , vol.29 , Issue.12 , pp. 875-878
    • Superti-Furga, A.1    Raghunath, M.2    Willems, P.J.3
  • 108
    • 0036272299 scopus 로고    scopus 로고
    • The Ocular Hypertension Treatment Study: Baseline factors that predict the onset of primary open-angle glaucoma
    • discussion 829
    • Gordon MO, Beiser JA, Brandt JD et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120:714-20; discussion 829.
    • (2002) Arch Ophthalmol , vol.120 , pp. 714-720
    • Gordon, M.O.1    Beiser, J.A.2    Brandt, J.D.3
  • 110
    • 49049107379 scopus 로고    scopus 로고
    • Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients
    • Wells AP, Garway-Heath DF, Poostchi A, Wong T, Chan KC, Sachdev N. Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci. 2008;49:3262-3268.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3262-3268
    • Wells, A.P.1    Garway-Heath, D.F.2    Poostchi, A.3    Wong, T.4    Chan, K.C.5    Sachdev, N.6
  • 111
    • 42049095265 scopus 로고    scopus 로고
    • Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON)
    • Bochmann F, Ang GS, Azuara-Blanco A. Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON). Graefes Arch Clin Exp Ophthalmol. 2008;246:735-738.
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 735-738
    • Bochmann, F.1    Ang, G.S.2    Azuara-Blanco, A.3
  • 114
    • 67349134656 scopus 로고    scopus 로고
    • Recovery of corneal hysteresis after reduction of intraocular pressure in chronic primary angle-closure glaucoma
    • Sun L, Shen M, Wang J et al. Recovery of corneal hysteresis after reduction of intraocular pressure in chronic primary angle-closure glaucoma. Am J Ophthalmol. 2009;147:1061-6, 1066.e1.
    • (2009) Am J Ophthalmol , vol.147
    • Sun, L.1    Shen, M.2    Wang, J.3
  • 115
    • 54049152415 scopus 로고    scopus 로고
    • Ocular response analyser to assess hysteresis and corneal resistance factor in low tension, open angle glaucoma and ocular hypertension
    • Shah S, Laiquzzaman M, Mantry S, Cunliffe I. Ocular response analyser to assess hysteresis and corneal resistance factor in low tension, open angle glaucoma and ocular hypertension. Clin Experiment Ophthalmol. 2008;36:508-513.
    • (2008) Clin Experiment Ophthalmol , vol.36 , pp. 508-513
    • Shah, S.1    Laiquzzaman, M.2    Mantry, S.3    Cunliffe, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.