메뉴 건너뛰기




Volumn 33, Issue 8, 2007, Pages 1371-1375

Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BIOMECHANICS; CHILD; CONTROLLED STUDY; CORNEA; CORNEA DISEASE; DIAGNOSTIC TEST; FEMALE; HUMAN; HYSTERESIS; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MALE; MYOPIA; OPERATING ROOM PERSONNEL; OUTCOME ASSESSMENT; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; REFRACTION ERROR; REFRACTIVE SURGERY; TREATMENT OUTCOME;

EID: 34547105084     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.04.021     Document Type: Article
Times cited : (361)

References (21)
  • 1
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • Orssengo G.J., and Pye D.C. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol 61 (1999) 551-572
    • (1999) Bull Math Biol , vol.61 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 2
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement; quantitative analysis
    • Liu J., and Roberts C.J. Influence of corneal biomechanical properties on intraocular pressure measurement; quantitative analysis. J Cataract Refract Surg 31 (2005) 146-155
    • (2005) J Cataract Refract Surg , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 3
    • 33646901276 scopus 로고    scopus 로고
    • Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    • Herndon L.W. Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol 17 (2006) 115-119
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 115-119
    • Herndon, L.W.1
  • 4
    • 0030297968 scopus 로고    scopus 로고
    • Constitutive laws for biomechanical modeling of refractive surgery
    • Bryant M.R., and McDonnell P.J. Constitutive laws for biomechanical modeling of refractive surgery. J Biomech Eng 118 (1996) 473-481
    • (1996) J Biomech Eng , vol.118 , pp. 473-481
    • Bryant, M.R.1    McDonnell, P.J.2
  • 5
    • 0036745768 scopus 로고    scopus 로고
    • Biomechanical response of the cornea to phototherapeutic keratectomy when treated as a fluid-filled porous material
    • Katsube N., Wang R., Okuma E., and Roberts C. Biomechanical response of the cornea to phototherapeutic keratectomy when treated as a fluid-filled porous material. J Refract Surg 18 (2002) S593-S597
    • (2002) J Refract Surg , vol.18
    • Katsube, N.1    Wang, R.2    Okuma, E.3    Roberts, C.4
  • 6
    • 0036744718 scopus 로고    scopus 로고
    • Biomechanics of the cornea and wavefront-guided laser refractive surgery
    • Roberts C. Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg 18 (2002) S589-S592
    • (2002) J Refract Surg , vol.18
    • Roberts, C.1
  • 7
    • 7644227843 scopus 로고    scopus 로고
    • Structural analysis of the cornea using scanning-slit corneal topography in eyes undergoing excimer laser refractive surgery
    • Kamiya K., Miyata K., Tokunaga T., et al. Structural analysis of the cornea using scanning-slit corneal topography in eyes undergoing excimer laser refractive surgery. Cornea 23 suppl 1 (2004) S59-S64
    • (2004) Cornea , vol.23 , Issue.SUPPL. 1
    • Kamiya, K.1    Miyata, K.2    Tokunaga, T.3
  • 8
    • 13844317405 scopus 로고    scopus 로고
    • Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgery
    • Jaycock P.D., Lobo L., Ibrahim J., et al. Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgery. J Cataract Refract Surg 31 (2005) 175-184
    • (2005) J Cataract Refract Surg , vol.31 , pp. 175-184
    • Jaycock, P.D.1    Lobo, L.2    Ibrahim, J.3
  • 9
    • 34547136324 scopus 로고
    • Measurements of corneal elasticity in relation to disease, using the Wiegersma elastometer
    • Mamelok A.E., and Posner A. Measurements of corneal elasticity in relation to disease, using the Wiegersma elastometer. Am J Ophthalmol 39 (1955) 817-821
    • (1955) Am J Ophthalmol , vol.39 , pp. 817-821
    • Mamelok, A.E.1    Posner, A.2
  • 10
    • 0018904122 scopus 로고
    • Brillouin scattering, density and elastic properties of the lens and cornea of the eye
    • [letter]
    • Vaughan J.M., and Randall J.T. Brillouin scattering, density and elastic properties of the lens and cornea of the eye. [letter]. Nature 284 (1980) 489-491
    • (1980) Nature , vol.284 , pp. 489-491
    • Vaughan, J.M.1    Randall, J.T.2
  • 11
    • 0027320151 scopus 로고
    • Measurement of elastic modulus of the bovine cornea by means of holographic interferometry. Part 1. Method and experiment
    • Kasprzak H., Förster W., and von Bally G. Measurement of elastic modulus of the bovine cornea by means of holographic interferometry. Part 1. Method and experiment. Optom Vis Sci 70 (1993) 535-544
    • (1993) Optom Vis Sci , vol.70 , pp. 535-544
    • Kasprzak, H.1    Förster, W.2    von Bally, G.3
  • 12
    • 0030561003 scopus 로고    scopus 로고
    • An ultrasonic technique for the measurement of the elastic moduli of human cornea
    • Wang H., Prendiville P.L., McDonnell P.J., and Chang W.V. An ultrasonic technique for the measurement of the elastic moduli of human cornea. J Biomech 29 (1996) 1633-1636
    • (1996) J Biomech , vol.29 , pp. 1633-1636
    • Wang, H.1    Prendiville, P.L.2    McDonnell, P.J.3    Chang, W.V.4
  • 15
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce D.A. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31 (2005) 156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 16
    • 34547119413 scopus 로고    scopus 로고
    • Rabinowitz YS. Definition, etiology, and diagnosis of keratoconus. In: Alió JL, Belda JI, eds, Treating Irregular Astigmatism and Keratoconus. El Dorado, Panama, Highlights of Ophthalmology International, 2004; 241-260
  • 17
    • 33745216716 scopus 로고    scopus 로고
    • Corneal higher order aberrations: a method to grade keratoconus
    • Alió J.L., and Shabayek M.H. Corneal higher order aberrations: a method to grade keratoconus. J Refract Surg 22 (2006) 539-545
    • (2006) J Refract Surg , vol.22 , pp. 539-545
    • Alió, J.L.1    Shabayek, M.H.2
  • 18
    • 33747884984 scopus 로고    scopus 로고
    • Biomechanics and wound healing in the cornea
    • Dupps Jr. W.J., and Wilson S.E. Biomechanics and wound healing in the cornea. Exp Eye Res 83 (2006) 709-720
    • (2006) Exp Eye Res , vol.83 , pp. 709-720
    • Dupps Jr., W.J.1    Wilson, S.E.2
  • 19
    • 15544363415 scopus 로고    scopus 로고
    • Biomechanical modeling of corneal ectasia
    • Dupps Jr. W.J. Biomechanical modeling of corneal ectasia. J Refract Surg 21 (2005) 186-190
    • (2005) J Refract Surg , vol.21 , pp. 186-190
    • Dupps Jr., W.J.1
  • 20
    • 15544373161 scopus 로고    scopus 로고
    • Theoretical elastic response of the cornea to refractive surgery: risk factors for keratectasia
    • Guirao A. Theoretical elastic response of the cornea to refractive surgery: risk factors for keratectasia. J Refract Surg 21 (2005) 176-185
    • (2005) J Refract Surg , vol.21 , pp. 176-185
    • Guirao, A.1
  • 21
    • 33646190149 scopus 로고    scopus 로고
    • Central corneal thickness and corneal hysteresis associated with glaucoma damage
    • Congdon N.G., Broman A.T., Bandeen-Roche K., et al. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol 141 (2006) 868-875
    • (2006) Am J Ophthalmol , vol.141 , pp. 868-875
    • Congdon, N.G.1    Broman, A.T.2    Bandeen-Roche, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.