메뉴 건너뛰기




Volumn 33, Issue 9, 2007, Pages 1499-1501

Hysteresis: New mechanospeak for the ophthalmologist

(1)  Dupps Jr , William J a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC PRESSURE; BIOMECHANICS; CORNEA; EDITORIAL; ENERGY ABSORPTION; GEOMETRY; HUMAN; HYSTERESIS; INTRAOCULAR HYPERTENSION; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOMILEUSIS; MEASUREMENT; OPHTHALMOLOGY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; REFRACTIVE SURGERY; RISK ASSESSMENT; VISCOELASTICITY; WAVEFORM; YOUNG MODULUS;

EID: 34548027735     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.07.008     Document Type: Editorial
Times cited : (74)

References (9)
  • 1
    • 0036272299 scopus 로고    scopus 로고
    • The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma
    • Gordon M.O., Beiser J.A., Brandt J.D., et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 120 (2002) 714-720
    • (2002) Arch Ophthalmol , vol.120 , pp. 714-720
    • Gordon, M.O.1    Beiser, J.A.2    Brandt, J.D.3
  • 2
    • 0036269745 scopus 로고    scopus 로고
    • Answers from the Ocular Hypertension Treatment Study
    • [editorial]
    • Palmberg P. Answers from the Ocular Hypertension Treatment Study. [editorial]. Arch Ophthalmol 120 (2002) 829-830
    • (2002) Arch Ophthalmol , vol.120 , pp. 829-830
    • Palmberg, P.1
  • 3
    • 0026748686 scopus 로고
    • Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas
    • Hoeltzel D.A., Altman P., Buzard K., and Choe K. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas. J Biomech Eng 114 (1992) 202-215
    • (1992) J Biomech Eng , vol.114 , pp. 202-215
    • Hoeltzel, D.A.1    Altman, P.2    Buzard, K.3    Choe, K.4
  • 4
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce D.A. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31 (2005) 156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 5
    • 0001063063 scopus 로고
    • Contribution to the theory and practice of tonometry
    • Friedenwald J.S. Contribution to the theory and practice of tonometry. Am J Ophthalmol 20 (1937) 985-1024
    • (1937) Am J Ophthalmol , vol.20 , pp. 985-1024
    • Friedenwald, J.S.1
  • 6
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer
    • Medeiros F.A., and Weinreb R.N. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer. J Glaucoma 15 (2006) 364-370
    • (2006) J Glaucoma , vol.15 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 7
    • 33646190149 scopus 로고    scopus 로고
    • Central corneal thickness and corneal hysteresis associated with glaucoma damage
    • Congdon N.G., Broman A.T., Bandeen-Roche K., et al. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol 141 (2006) 868-875
    • (2006) Am J Ophthalmol , vol.141 , pp. 868-875
    • Congdon, N.G.1    Broman, A.T.2    Bandeen-Roche, K.3
  • 8
    • 34548022426 scopus 로고    scopus 로고
    • Assessment of the biomechanical properties of the cornea with the Ocular Response Analyzer in normal and keratoconic eyes
    • Shah S., Laiquzzaman M., Bhojwani R., et al. Assessment of the biomechanical properties of the cornea with the Ocular Response Analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 48 (2007) 3026-3031
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 3026-3031
    • Shah, S.1    Laiquzzaman, M.2    Bhojwani, R.3
  • 9
    • 33845499055 scopus 로고    scopus 로고
    • Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
    • Pepose J.S., Feigenbaum S.K., Qazi M.A., et al. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol 143 (2007) 39-47
    • (2007) Am J Ophthalmol , vol.143 , pp. 39-47
    • Pepose, J.S.1    Feigenbaum, S.K.2    Qazi, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.