메뉴 건너뛰기




Volumn 105, Issue 10, 2008, Pages 916-920

Measurement of viscoelastic corneal parameters (corneal hysteresis) in patients with primary open angle glaucoma;Bestimmung viskoelastischer Hornhauteigenschaften (korneale Hysterese) bei Patienten mit primärem Offenwinkelglaukom

Author keywords

Corneal biomechanics; Corneal hysteresis; Dynamic tonometry; Ocular response analyzer; Open angle glaucoma

Indexed keywords

ANTIHYPERTENSIVE AGENT;

EID: 63349107518     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-008-1690-6     Document Type: Article
Times cited : (20)

References (11)
  • 1
    • 33646190149 scopus 로고    scopus 로고
    • Congdon NG, Broman AT, Bandeen-Roche K et al. (2006) Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol 141: 868-875.
    • (2006) Am J Ophthalmol , vol.141 , pp. 868-875
    • Congdon1
  • 2
    • 34547349120 scopus 로고    scopus 로고
    • Der Einfluß von kornealer Hysterese und kornealem Resistenzfaktor auf die Messung des intaokularen Druckes
    • Hager A, Schroeder B, Sadeghi M et al. (2007) Der Einfluß von kornealer Hysterese und kornealem Resistenzfaktor auf die Messung des intaokularen Druckes. Ophthalmologe 104: 484-489.
    • (2007) Ophthalmologe , vol.104 , pp. 484-489
    • Hager, A.1    Schroeder, B.2    Sadeghi, M.3
  • 3
    • 34548203771 scopus 로고    scopus 로고
    • Changes in corneal hysteresis after clear corneal cataract surgery
    • Hager A, Loge K, Füllhas M et al. (2007) Changes in corneal hysteresis after clear corneal cataract surgery. Am J Ophthalmol 144: 341-346.
    • (2007) Am J Ophthalmol , vol.144 , pp. 341-346
    • Hager, A.1    Loge, K.2    Füllhas, M.3
  • 4
    • 33845227093 scopus 로고    scopus 로고
    • Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer
    • Kirwan C, O'Keefe M, Lanigan B (2006) Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer. Am J Ophthalmol 142: 990-992.
    • (2006) Am J Ophthalmol , vol.142 , pp. 990-992
    • Kirwan, C.1    O'Keefe, M.2    Lanigan, B.3
  • 5
    • 34248347895 scopus 로고    scopus 로고
    • Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    • Kotecha A, Elsheikh A, Roberts CR et al. (2006) Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest Ophthalmol Vis Sci 47: 5337-5347.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 5337-5347
    • Kotecha1
  • 6
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cat Refract Surg 31: 156-162.
    • (2005) J Cat Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 7
    • 33750591541 scopus 로고    scopus 로고
    • Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements
    • Martinez de la Casa JM, Garcia-Feijoo J, Fernandez-Vidal A et al. (2006) Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Invest Ophthalmol Vis Sci 47: 4410-4414.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 4410-4414
    • de la Casa Martinez, J.M.1    Garcia-Feijoo, J.2    Fernandez-Vidal, A.3
  • 8
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal properties on intraocular pressure measurements using the ocular response analyzer
    • Medeiros FA, Weinreb RN 2006 Evaluation of the influence of corneal properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma 15: 364-370.
    • (2006) J Glaucoma , vol.15 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 9
    • 33845499055 scopus 로고    scopus 로고
    • 2007 Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
    • Pepose JS, Feigenbaum SK, Qazi MA et al. 2007 Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol 143: 39-47.
    • Am J Ophthalmol , vol.143 , pp. 39-47
    • Pepose, J.S.1    Feigenbaum, S.K.2    Qazi, M.A.3
  • 10
    • 33747069382 scopus 로고    scopus 로고
    • Post-laser in-situ keratomileusis ectasia: Current understanding and future directions
    • Randleman JB (2006) Post-laser in-situ keratomileusis ectasia: current understanding and future directions. Curr Opin Ophthalmol 17: 406-412.
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 406-412
    • Randleman, J.B.1
  • 11
    • 33750995542 scopus 로고    scopus 로고
    • Shah S, Laiquzzaman M, Cunliffe I et al. (2006) The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes. Cont Lens Anterior Eye 29: 257-262.
    • (2006) Cont Lens Anterior Eye , vol.29 , pp. 257-262
    • Shah, S.1    Laiquzzaman, M.2    Cunliffe, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.