메뉴 건너뛰기




Volumn 142, Issue 6, 2006, Pages 990-992

Correction (DOI:10.1016/j.ajo.2006.07.058);Corneal Hysteresis and Intraocular Pressure Measurement in Children Using the Reichert Ocular Response Analyzer

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ANALYZER; ARTICLE; CHILD; CLINICAL ARTICLE; CLINICAL EXAMINATION; CLINICAL PRACTICE; CLINICAL TRIAL; CONGENITAL GLAUCOMA; CORNEA; CORRELATION ANALYSIS; FEMALE; GROUPS BY AGE; HUMAN; HYSTERESIS; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; MALE; NORMAL HUMAN; NYSTAGMUS; OBSERVATIONAL STUDY; PRESSURE MEASUREMENT; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; TONOMETRY;

EID: 33845227093     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajo.2007.08.008     Document Type: Erratum
Times cited : (136)

References (4)
  • 1
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce D.A. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31 (2005) 156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 2
    • 0028889446 scopus 로고
    • Tonometry in pediatric patients: a comparative study among Tono-Pen, Perkins and Schiotz tonometers
    • Bordon A.F., Katsumi O., and Hirose T. Tonometry in pediatric patients: a comparative study among Tono-Pen, Perkins and Schiotz tonometers. J Pediatr Ophthalmol Strabismus 32 (1995) 373-377
    • (1995) J Pediatr Ophthalmol Strabismus , vol.32 , pp. 373-377
    • Bordon, A.F.1    Katsumi, O.2    Hirose, T.3
  • 3
    • 23644458260 scopus 로고    scopus 로고
    • Is the Tono-Pen accurate for measuring intraocular pressure in young children with congenital glaucoma?
    • Levy J., Lifshitz T., Rosen S., Tessler Z., and Biedner B.Z. Is the Tono-Pen accurate for measuring intraocular pressure in young children with congenital glaucoma?. J AAPOS 9 (2005) 321-325
    • (2005) J AAPOS , vol.9 , pp. 321-325
    • Levy, J.1    Lifshitz, T.2    Rosen, S.3    Tessler, Z.4    Biedner, B.Z.5
  • 4
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs other portable tonometers in healthy eyes
    • Garcia-Resua C., Gonzalez-Meijome J.M., Gilino J., and Yebra-Pimental E. Accuracy of the new ICare rebound tonometer vs other portable tonometers in healthy eyes. Optom Vis Sci 83 (2006) 102-107
    • (2006) Optom Vis Sci , vol.83 , pp. 102-107
    • Garcia-Resua, C.1    Gonzalez-Meijome, J.M.2    Gilino, J.3    Yebra-Pimental, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.