Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use
-
Gross, T.M.; Bode, B.W.; Einhorn, D.; Kayne, D.M.; Reed, J.H.; White, N.H.; Mastrototaro, J.J. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol. Ther. 2000, 2, 49–56.
-
(2000)
Diabetes Technol. Ther.
, vol.2
, pp. 49-56
-
-
Gross, T.M.1
Bode, B.W.2
Einhorn, D.3
Kayne, D.M.4
Reed, J.H.5
White, N.H.6
Mastrototaro, J.J.7
-
2
-
-
0242363717
-
A continuous glucose sensor based on wired enzyme technology—Results from a 3-day trial in patients with type 1 diabetes
-
Feldman, B.; Brazg, R.; Schwartz, S.; Weinstein, R. A continuous glucose sensor based on wired enzyme technology—Results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol. Ther. 2003, 5, 769–779.
-
(2003)
Diabetes Technol. Ther.
, vol.5
, pp. 769-779
-
-
Feldman, B.1
Brazg, R.2
Schwartz, S.3
Weinstein, R.4
-
3
-
-
1842583012
-
Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: The guardian continuous monitoring system
-
Bode, B.; Gross, K.; Rikalo, N.; Schwartz, S.; Wahl, T.; Page, C.; Gross, T.; Mastrototaro, J. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Diabetes Technol. Ther. 2004, 6, 105–113.
-
(2004)
Diabetes Technol. Ther.
, vol.6
, pp. 105-113
-
-
Bode, B.1
Gross, K.2
Rikalo, N.3
Schwartz, S.4
Wahl, T.5
Page, C.6
Gross, T.7
Mastrototaro, J.8
-
4
-
-
77949879803
-
New features and performance of a next-generation SEVEN-day continuous glucose monitoring system with short lag time
-
Bailey, T.; Zisser, H.; Chang, A. New features and performance of a next-generation SEVEN-day continuous glucose monitoring system with short lag time. Diabetes Technol. Ther. 2009, 11, 749–755.
-
(2009)
Diabetes Technol. Ther.
, vol.11
, pp. 749-755
-
-
Bailey, T.1
Zisser, H.2
Chang, A.3
-
5
-
-
84884562284
-
A new-generation continuous glucose monitoring system: Improved accuracy and reliability compared with a previous-generation system
-
Christiansen, M.; Bailey, T.; Watkins, E.; Liljenquist, D.; Price, D.; Nakamura, K.; Boock, R.; Peyser, T. A new-generation continuous glucose monitoring system: Improved accuracy and reliability compared with a previous-generation system. Diabetes Technol. Ther. 2013, 15, 881–888.
-
(2013)
Diabetes Technol. Ther.
, vol.15
, pp. 881-888
-
-
Christiansen, M.1
Bailey, T.2
Watkins, E.3
Liljenquist, D.4
Price, D.5
Nakamura, K.6
Boock, R.7
Peyser, T.8
-
6
-
-
85016145364
-
-
Dexcom G5 Mobile. Available online: https://www.dexcom.com/g5-mobile-cgm (accessed on 23 June 2016).
-
(2016)
Dexcom G5 Mobile
-
-
-
7
-
-
50049108982
-
The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes
-
Mastrototaro, J.; Shin, J.; Marcus, A.; Sulur, G.; Abelseth, J.; Bode, B.W.; Buckingham, B.A.; Hirsch, I.B.; Kaufman, F.R.; Schwartz, S.L.; et al. The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol. Ther. 2008, 10, 385–390.
-
(2008)
Diabetes Technol. Ther
, vol.10
, pp. 385-390
-
-
Mastrototaro, J.1
Shin, J.2
Marcus, A.3
Sulur, G.4
Abelseth, J.5
Bode, B.W.6
Buckingham, B.A.7
Hirsch, I.B.8
Kaufman, F.R.9
Schwartz, S.L.10
-
8
-
-
54849147700
-
Continuous glucose monitoring and intensive treatment of type 1 diabetes
-
Tamborlane, W.V.; Beck, R.W.; Bode, B.W.; Buckingham, B.; Chase, H.P.; Clemons, R.; Fiallo-Scharer, R.; Fox, L.A.; Gilliam, L.K.; Hirsch, I.B.; et al. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N. Engl. J. Med. 2008, 359, 1464–1476.
-
(2008)
N. Engl. J. Med
, vol.359
, pp. 1464-1476
-
-
Tamborlane, W.V.1
Beck, R.W.2
Bode, B.W.3
Buckingham, B.4
Chase, H.P.5
Clemons, R.6
Fiallo-Scharer, R.7
Fox, L.A.8
Gilliam, L.K.9
Hirsch, I.B.10
-
9
-
-
84879700650
-
Predicting subcutaneous glucose concentration using a latent-variable-based statistical method for type 1 diabetes mellitus
-
Zhao, C.; Dassau, E.; Jovanovi, L.; Zisser, H.C.; Doyle, F.J.; Seborg, D.E. Predicting subcutaneous glucose concentration using a latent-variable-based statistical method for type 1 diabetes mellitus. J. Diabetes Sci. Technol. 2012, 6, 617–633.
-
(2012)
J. Diabetes Sci. Technol.
, vol.6
, pp. 617-633
-
-
Zhao, C.1
Dassau, E.2
Jovanovi, L.3
Zisser, H.C.4
Doyle, F.J.5
Seborg, D.E.6
-
10
-
-
84883659887
-
Hypoglycemia Early Alarm Systems Based On Multivariable Models
-
Turksoy, K.; Bayrak, E.S.; Quinn, L.; Littlejohn, E.; Rollins, D.; Cinar, A. Hypoglycemia Early Alarm Systems Based On Multivariable Models. Ind. Eng. Chem. Res. 2013, 52, 12329–12336.
-
(2013)
Ind. Eng. Chem. Res.
, vol.52
, pp. 12329-12336
-
-
Turksoy, K.1
Bayrak, E.S.2
Quinn, L.3
Littlejohn, E.4
Rollins, D.5
Cinar, A.6
-
11
-
-
84948711108
-
Comparative assessment of glucose prediction models for patients with type 1 diabetes mellitus applying sensors for glucose and physical activity monitoring
-
Zarkogianni, K.; Mitsis, K.; Litsa, E.; Arredondo, M.T.; Fico, G.; Fioravanti, A.; Nikita, K.S. Comparative assessment of glucose prediction models for patients with type 1 diabetes mellitus applying sensors for glucose and physical activity monitoring. Med. Biol. Eng. Comput. 2015, 53, 1333–1343.
-
(2015)
Med. Biol. Eng. Comput.
, vol.53
, pp. 1333-1343
-
-
Zarkogianni, K.1
Mitsis, K.2
Litsa, E.3
Arredondo, M.T.4
Fico, G.5
Fioravanti, A.6
Nikita, K.S.7
-
12
-
-
84929075114
-
Rapid model identification for online subcutaneous glucose concentration prediction for new subjects with type I diabetes
-
Zhao, C.; Yu, C. Rapid model identification for online subcutaneous glucose concentration prediction for new subjects with type I diabetes. IEEE Trans. Biomed. Eng. 2015, 62, 1333–1344.
-
(2015)
IEEE Trans. Biomed. Eng.
, vol.62
, pp. 1333-1344
-
-
Zhao, C.1
Yu, C.2
-
13
-
-
85012982071
-
How Much Is Short-Term Glucose Prediction in Type 1 Diabetes Improved by Adding Insulin Delivery and Meal Content Information to CGM Data? A Proof-of-Concept Study
-
Zecchin, C.; Facchinetti, A.; Sparacino, G.; Cobelli, C. How Much Is Short-Term Glucose Prediction in Type 1 Diabetes Improved by Adding Insulin Delivery and Meal Content Information to CGM Data? A Proof-of-Concept Study. J. Diabetes Sci. Technol. 2016, 10, 1149–1160.
-
(2016)
J. Diabetes Sci. Technol.
, vol.10
, pp. 1149-1160
-
-
Zecchin, C.1
Facchinetti, A.2
Sparacino, G.3
Cobelli, C.4
-
14
-
-
79952197615
-
Hypoglycemia prevention via pump attenuation and red-yellow-green “traffic” lights using continuous glucose monitoring and insulin pump data
-
Hughes, C.S.; Patek, S.D.; Breton, M.D.; Kovatchev, B.P. Hypoglycemia prevention via pump attenuation and red-yellow-green “traffic” lights using continuous glucose monitoring and insulin pump data. J. Diabetes Sci. Technol. 2010, 4, 1146–1155.
-
(2010)
J. Diabetes Sci. Technol.
, vol.4
, pp. 1146-1155
-
-
Hughes, C.S.1
Patek, S.D.2
Breton, M.D.3
Kovatchev, B.P.4
-
15
-
-
84869081609
-
Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm
-
Cameron, F.; Wilson, D.M.; Buckingham, B.A.; Arzumanyan, H.; Clinton, P.; Chase, H.P.; Lum, J.; Maahs, D.M.; Calhoun, P.M.; Bequette, B.W. Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm. J. Diabetes Sci. Technol. 2012, 6, 1142–1147.
-
(2012)
J. Diabetes Sci. Technol.
, vol.6
, pp. 1142-1147
-
-
Cameron, F.1
Wilson, D.M.2
Buckingham, B.A.3
Arzumanyan, H.4
Clinton, P.5
Chase, H.P.6
Lum, J.7
Maahs, D.M.8
Calhoun, P.M.9
Bequette, B.W.10
-
16
-
-
85016650133
-
Predictors of Hypoglycemia in the ASPIRE In-Home Study and Effects of Automatic Suspension of Insulin Delivery
-
Weiss, R.; Garg, S.K.; Bergenstal, R.M.; Klonoff, D.C.; Bode, B.W.; Bailey, T.S.; Thrasher, J.; Schwartz, F.; Welsh, J.B.; Kaufman, F.R.; et al. Predictors of Hypoglycemia in the ASPIRE In-Home Study and Effects of Automatic Suspension of Insulin Delivery. J. Diabetes Sci. Technol. 2015, 9, 1016–1020.
-
(2015)
J. Diabetes Sci. Technol
, vol.9
, pp. 1016-1020
-
-
Weiss, R.1
Garg, S.K.2
Bergenstal, R.M.3
Klonoff, D.C.4
Bode, B.W.5
Bailey, T.S.6
Thrasher, J.7
Schwartz, F.8
Welsh, J.B.9
Kaufman, F.R.10
-
17
-
-
84869083356
-
Robust fault detection system for insulin pump therapy using continuous glucose monitoring
-
Herrero, P.; Calm, R.; Vehi, J.; Armengol, J.; Georgiou, P.; Oliver, N.; Tomazou, C. Robust fault detection system for insulin pump therapy using continuous glucose monitoring. J. Diabetes Sci. Technol. 2012, 6, 1131–1141.
-
(2012)
J. Diabetes Sci. Technol.
, vol.6
, pp. 1131-1141
-
-
Herrero, P.1
Calm, R.2
Vehi, J.3
Armengol, J.4
Georgiou, P.5
Oliver, N.6
Tomazou, C.7
-
18
-
-
84872538703
-
An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects
-
Facchinetti, A.; Del Favero, S.; Sparacino, G.; Cobelli, C. An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects. IEEE Trans. Biomed. Eng. 2013, 60, 406–416.
-
(2013)
IEEE Trans. Biomed. Eng.
, vol.60
, pp. 406-416
-
-
Facchinetti, A.1
Del Favero, S.2
Sparacino, G.3
Cobelli, C.4
-
19
-
-
84929234318
-
A novel method to detect pressure-induced sensor attenuations (PISA) in an artificial pancreas
-
Baysal, N.; Cameron, F.; Buckingham, B.A.; Wilson, D.M.; Chase, H.P.; Maahs, D.M.; Bequette, B.W.; Buckingham, B.A.; Wilson, D.M.; Aye, T.; et al. A novel method to detect pressure-induced sensor attenuations (PISA) in an artificial pancreas. J. Diabetes Sci. Technol. 2014, 8, 1091–1096.
-
(2014)
J. Diabetes Sci. Technol
, vol.8
, pp. 1091-1096
-
-
Baysal, N.1
Cameron, F.2
Buckingham, B.A.3
Wilson, D.M.4
Chase, H.P.5
Maahs, D.M.6
Bequette, B.W.7
Buckingham, B.A.8
Wilson, D.M.9
Aye, T.10
-
20
-
-
85026676593
-
Real-Time Model-Based Fault Detection of Continuous Glucose Sensor Measurements
-
Turksoy, K.; Roy, A.; Cinar, A. Real-Time Model-Based Fault Detection of Continuous Glucose Sensor Measurements. IEEE Trans. Biomed. Eng. 2016, doi:10.1109/TBME.2016.2535412.
-
(2016)
IEEE Trans. Biomed. Eng.
-
-
Turksoy, K.1
Roy, A.2
Cinar, A.3
-
21
-
-
85009442776
-
Early Detection of Infusion Set Failure During Insulin Pump Therapy in Type 1 Diabetes
-
Cescon, M.; DeSalvo, D.J.; Ly, T.T.; Maahs, D.M.; Messer, L.H.; Buckingham, B.A.; Doyle, F.J.; Dassau, E. Early Detection of Infusion Set Failure During Insulin Pump Therapy in Type 1 Diabetes. J. Diabetes Sci. Technol. 2016, 10, 1268–1276.
-
(2016)
J. Diabetes Sci. Technol.
, vol.10
, pp. 1268-1276
-
-
Cescon, M.1
Desalvo, D.J.2
Ly, T.T.3
Maahs, D.M.4
Messer, L.H.5
Buckingham, B.A.6
Doyle, F.J.7
Dassau, E.8
-
22
-
-
84869088948
-
Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas
-
Bequette, B.W. Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas. Annu. Rev. Control. 2012, 36, 255–266.
-
(2012)
Annu. Rev. Control.
, vol.36
, pp. 255-266
-
-
Bequette, B.W.1
-
23
-
-
84898444019
-
The artificial pancreas: Current status and future prospects in the management of diabetes
-
Peyser, T.; Dassau, E.; Breton, M.; Skyler, J.S. The artificial pancreas: Current status and future prospects in the management of diabetes. Ann. N. Y. Acad. Sci. 2014, 1311, 102–123.
-
(2014)
Ann. N. Y. Acad. Sci.
, vol.1311
, pp. 102-123
-
-
Peyser, T.1
Dassau, E.2
Breton, M.3
Skyler, J.S.4
-
24
-
-
84908355084
-
The artificial pancreas: A digital-age treatment for diabetes
-
Cobelli, C.; Renard, E.; Kovatchev, B. The artificial pancreas: A digital-age treatment for diabetes. Lancet Diabetes Endocrinol. 2014, 2, 679–681.
-
(2014)
Lancet Diabetes Endocrinol
, vol.2
, pp. 679-681
-
-
Cobelli, C.1
Renard, E.2
Kovatchev, B.3
-
25
-
-
84976478311
-
Coming of age: The artificial pancreas for type 1 diabetes
-
Thabit, H.; Hovorka, R. Coming of age: The artificial pancreas for type 1 diabetes. Diabetologia 2016, 59, 1795–1805.
-
(2016)
Diabetologia
, vol.59
, pp. 1795-1805
-
-
Thabit, H.1
Hovorka, R.2
-
26
-
-
77957127872
-
“Smart” continuous glucose monitoring sensors: On-line signal processing issues
-
Sparacino, G.; Facchinetti, A.; Cobelli, C. “Smart” continuous glucose monitoring sensors: On-line signal processing issues. Sensors 2010, 10, 6751–6772.
-
(2010)
Sensors
, vol.10
, pp. 6751-6772
-
-
Sparacino, G.1
Facchinetti, A.2
Cobelli, C.3
-
27
-
-
84875422729
-
Real-time improvement of continuous glucose monitoring accuracy: The smart sensor concept
-
Facchinetti, A.; Sparacino, G.; Guerra, S.; Luijf, Y.M.; DeVries, J.H.; Mader, J.K.; Ellmerer, M.; Benesch, C.; Heinemann, L.; Bruttomesso, D.; et al. Real-time improvement of continuous glucose monitoring accuracy: the smart sensor concept. Diabetes Care 2013, 36, 793–800.
-
(2013)
Diabetes Care
, vol.36
, pp. 793-800
-
-
Facchinetti, A.1
Sparacino, G.2
Guerra, S.3
Luijf, Y.M.4
Devries, J.H.5
Mader, J.K.6
Ellmerer, M.7
Benesch, C.8
Heinemann, L.9
Bruttomesso, D.10
-
28
-
-
84900524344
-
Signal processing algorithms implementing the “smart sensor” concept to improve continuous glucose monitoring in diabetes
-
Facchinetti, A.; Sparacino, G.; Cobelli, C. Signal processing algorithms implementing the “smart sensor” concept to improve continuous glucose monitoring in diabetes. J. Diabetes Sci. Technol. 2013, 7, 1308–1318.
-
(2013)
J. Diabetes Sci. Technol.
, vol.7
, pp. 1308-1318
-
-
Facchinetti, A.1
Sparacino, G.2
Cobelli, C.3
-
29
-
-
77649150209
-
An online self-tunable method to denoise CGM sensor data
-
Facchinetti, A.; Sparacino, G.; Cobelli, C. An online self-tunable method to denoise CGM sensor data. IEEE Trans. Biomed. Eng. 2010, 57, 634–641.
-
(2010)
IEEE Trans. Biomed. Eng.
, vol.57
, pp. 634-641
-
-
Facchinetti, A.1
Sparacino, G.2
Cobelli, C.3
-
30
-
-
80052042615
-
Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring
-
Facchinetti, A.; Sparacino, G.; Cobelli, C. Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring. IEEE Trans. Biomed. Eng. 2011, 58, 2664–2671.
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, pp. 2664-2671
-
-
Facchinetti, A.1
Sparacino, G.2
Cobelli, C.3
-
31
-
-
33744908804
-
Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care
-
Chase, J.G.; Hann, C.E.; Jackson, M.; Lin, J.; Lotz, T.; Wong, X.W.; Shaw, G.M. Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care. Comput. Methods Programs Biomed. 2006, 82, 238–247.
-
(2006)
Comput. Methods Programs Biomed.
, vol.82
, pp. 238-247
-
-
Chase, J.G.1
Hann, C.E.2
Jackson, M.3
Lin, J.4
Lotz, T.5
Wong, X.W.6
Shaw, G.M.7
-
32
-
-
54749149727
-
Hypoglycemia detection and prediction using continuous glucose monitoring-a study on hypoglycemic clamp data
-
Palerm, C.C.; Bequette, B.W. Hypoglycemia detection and prediction using continuous glucose monitoring-a study on hypoglycemic clamp data. J. Diabetes Sci. Technol. 2007, 1, 624–629.
-
(2007)
J. Diabetes Sci. Technol.
, vol.1
, pp. 624-629
-
-
Palerm, C.C.1
Bequette, B.W.2
-
33
-
-
34047167073
-
A dual-rate Kalman filter for continuous glucose monitoring
-
Kuure-Kinsey, M.; Palerm, C.C.; Bequette, B.W. A dual-rate Kalman filter for continuous glucose monitoring. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2006, 1, 63–66.
-
(2006)
Conf. Proc. IEEE Eng. Med. Biol. Soc.
, vol.1
, pp. 63-66
-
-
Kuure-Kinsey, M.1
Palerm, C.C.2
Bequette, B.W.3
-
34
-
-
84884566476
-
A multistep algorithm for processing and calibration of microdialysis continuous glucose monitoring data
-
Mahmoudi, Z.; Dencker Johansen, M.; Christiansen, J.S.; Hejlesen, O.K. A multistep algorithm for processing and calibration of microdialysis continuous glucose monitoring data. Diabetes Technol. Ther. 2013, 15, 825–835.
-
(2013)
Diabetes Technol. Ther.
, vol.15
, pp. 825-835
-
-
Mahmoudi, Z.1
Dencker Johansen, M.2
Christiansen, J.S.3
Hejlesen, O.K.4
-
35
-
-
84861405223
-
Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolution-based approach
-
Guerra, S.; Facchinetti, A.; Sparacino, G.; Nicolao, G.D.; Cobelli, C. Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolution-based approach. IEEE Trans. Biomed. Eng. 2012, 59, 1658–1669.
-
(2012)
IEEE Trans. Biomed. Eng.
, vol.59
, pp. 1658-1669
-
-
Guerra, S.1
Facchinetti, A.2
Sparacino, G.3
Nicolao, G.D.4
Cobelli, C.5
-
36
-
-
85029019243
-
On-line calibration of glucose sensors from the measured current by a time-varying calibration function and Bayesian priors
-
Vettoretti, M.; Facchinetti, A.; Del Favero, S.; Sparacino, G.; Cobelli, C. On-line calibration of glucose sensors from the measured current by a time-varying calibration function and Bayesian priors. IEEE Trans. Biomed. Eng. 2015, 63, 1631–1641.
-
(2015)
IEEE Trans. Biomed. Eng.
, vol.63
, pp. 1631-1641
-
-
Vettoretti, M.1
Facchinetti, A.2
Del Favero, S.3
Sparacino, G.4
Cobelli, C.5
-
37
-
-
84855461899
-
A multiple local models approach to accuracy improvement in continuous glucose monitoring
-
Barcelo-Rico, F.; Bondia, J.; Diez, J.L.; Rossetti, P. A multiple local models approach to accuracy improvement in continuous glucose monitoring. Diabetes Technol. Ther. 2012, 14, 74–82.
-
(2012)
Diabetes Technol. Ther.
, vol.14
, pp. 74-82
-
-
Barcelo-Rico, F.1
Bondia, J.2
Diez, J.L.3
Rossetti, P.4
-
38
-
-
84885133053
-
Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring
-
Barcelo-Rico, F.; Diez, J.L.; Rossetti, P.; Vehi, J.; Bondia, J. Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring. IEEE J. Biomed. Health Inform. 2013, 17, 530–538.
-
(2013)
IEEE J. Biomed. Health Inform.
, vol.17
, pp. 530-538
-
-
Barcelo-Rico, F.1
Diez, J.L.2
Rossetti, P.3
Vehi, J.4
Bondia, J.5
-
39
-
-
84941091951
-
LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors
-
Kirchsteiger, H.; Zaccarian, L.; Renard, E.; del Re, L. LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors. IEEE J. Biomed. Health Inform. 2015, 19, 1697–1706.
-
(2015)
IEEE J. Biomed. Health Inform.
, vol.19
, pp. 1697-1706
-
-
Kirchsteiger, H.1
Zaccarian, L.2
Renard, E.3
Del Re, L.4
-
40
-
-
34247372642
-
Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series
-
Sparacino, G.; Zanderigo, F.; Corazza, S.; Maran, A.; Facchinetti, A.; Cobelli, C. Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series. IEEE Trans. Biomed. Eng. 2007, 54, 931–937.
-
(2007)
IEEE Trans. Biomed. Eng.
, vol.54
, pp. 931-937
-
-
Sparacino, G.1
Zanderigo, F.2
Corazza, S.3
Maran, A.4
Facchinetti, A.5
Cobelli, C.6
-
41
-
-
84887823309
-
Jump neural network for online short-time prediction of blood glucose from continuous monitoring sensors and meal information
-
Zecchin, C.; Facchinetti, A.; Sparacino, G.; Cobelli, C. Jump neural network for online short-time prediction of blood glucose from continuous monitoring sensors and meal information. Comput. Methods Programs Biomed. 2014, 113, 144–152.
-
(2014)
Comput. Methods Programs Biomed.
, vol.113
, pp. 144-152
-
-
Zecchin, C.1
Facchinetti, A.2
Sparacino, G.3
Cobelli, C.4
-
42
-
-
84882272395
-
Multivariate prediction of subcutaneous glucose concentration in type 1 diabetes patients based on support vector regression
-
Georga, E.I.; Protopappas, V.C.; Ardigo, D.; Marina, M.; Zavaroni, I.; Polyzos, D.; Fotiadis, D.I. Multivariate prediction of subcutaneous glucose concentration in type 1 diabetes patients based on support vector regression. IEEE J. Biomed. Health Inform. 2013, 17, 71–81.
-
(2013)
IEEE J. Biomed. Health Inform.
, vol.17
, pp. 71-81
-
-
Georga, E.I.1
Protopappas, V.C.2
Ardigo, D.3
Marina, M.4
Zavaroni, I.5
Polyzos, D.6
Fotiadis, D.I.7
-
43
-
-
84948719040
-
Evaluation of short-term predictors of glucose concentration in type 1 diabetes combining feature ranking with regression models
-
Georga, E.I.; Protopappas, V.C.; Polyzos, D.; Fotiadis, D.I. Evaluation of short-term predictors of glucose concentration in type 1 diabetes combining feature ranking with regression models. Med. Biol. Eng. Comput. 2015, 53, 1305–1318.
-
(2015)
Med. Biol. Eng. Comput.
, vol.53
, pp. 1305-1318
-
-
Georga, E.I.1
Protopappas, V.C.2
Polyzos, D.3
Fotiadis, D.I.4
-
44
-
-
84898479663
-
Dexcom G4AP: An advanced continuous glucose monitor for the artificial pancreas
-
Garcia, A.; Rack-Gomer, A.L.; Bhavaraju, N.C.; Hampapuram, H.; Kamath, A.; Peyser, T.; Facchinetti, A.; Zecchin, C.; Sparacino, G.; Cobelli, C. Dexcom G4AP: An advanced continuous glucose monitor for the artificial pancreas. J. Diabetes Sci. Technol. 2013, 7, 1436–1445.
-
(2013)
J. Diabetes Sci. Technol.
, vol.7
, pp. 1436-1445
-
-
Garcia, A.1
Rack-Gomer, A.L.2
Bhavaraju, N.C.3
Hampapuram, H.4
Kamath, A.5
Peyser, T.6
Facchinetti, A.7
Zecchin, C.8
Sparacino, G.9
Cobelli, C.10
-
45
-
-
84938562819
-
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
-
Bailey, T.S.; Chang, A.; Christiansen, M. Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm. J. Diabetes Sci. Technol. 2015, 9, 209–214.
-
(2015)
J. Diabetes Sci. Technol.
, vol.9
, pp. 209-214
-
-
Bailey, T.S.1
Chang, A.2
Christiansen, M.3
-
46
-
-
85012980073
-
Nonadjunctive Use of Continuous Glucose Monitoring for Diabetes Treatment Decisions
-
Castle, J.R.; Jacobs, P.G. Nonadjunctive Use of Continuous Glucose Monitoring for Diabetes Treatment Decisions. J. Diabetes Sci. Technol. 2016, doi:10.1177/1932296816631569.
-
(2016)
J. Diabetes Sci. Technol.
-
-
Castle, J.R.1
Jacobs, P.G.2
-
47
-
-
84923873485
-
Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring
-
Kovatchev, B.P.; Patek, S.D.; Ortiz, E.A.; Breton, M.D. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring. Diabetes Technol. Ther. 2015, 17, 177–186.
-
(2015)
Diabetes Technol. Ther.
, vol.17
, pp. 177-186
-
-
Kovatchev, B.P.1
Patek, S.D.2
Ortiz, E.A.3
Breton, M.D.4
-
48
-
-
84991033774
-
Empirical Representation of Blood Glucose Variability in a Compartmental Model
-
Design, Use and Evaluation; Kirchsteiger, H., Jørgensen, B.J., Renard, E., del Re, L., Eds.; Springer: Cham, Switzerland
-
Patek, S.D.; Lv, D.; Ortiz, E.A.; Hughes-Karvetski, C.; Kulkarni, S.; Zhang, Q.; Breton, M.D. Empirical Representation of Blood Glucose Variability in a Compartmental Model. In Prediction Methods for Blood Glucose Concentration: Design, Use and Evaluation; Kirchsteiger, H., Jørgensen, B.J., Renard, E., del Re, L., Eds.; Springer: Cham, Switzerland, 2016; pp. 133–157.
-
(2016)
Prediction Methods for Blood Glucose Concentration
, pp. 133-157
-
-
Patek, S.D.1
Lv, D.2
Ortiz, E.A.3
Hughes-Karvetski, C.4
Kulkarni, S.5
Zhang, Q.6
Breton, M.D.7
-
49
-
-
85016151570
-
Silico assessment of biomedical products: The conundrum of rare but not so rare events
-
submitted
-
Viceconti, M.; Cobelli, C.; Haddad, T.; Kovatchev, B.; Palmer, M. In silico assessment of biomedical products: The conundrum of rare but not so rare events. J. Eng. Med. 2016, submitted.
-
(2016)
J. Eng. Med
-
-
Viceconti, M.1
Cobelli, C.2
Haddad, T.3
Kovatchev, B.4
Palmer, M.5
-
50
-
-
84997427243
-
Predicting insulin treatment scenarios with the net effect method: Domain of validity
-
Vettoretti, M.; Facchinetti, A.; Sparacino, G.; Cobelli, C. Predicting insulin treatment scenarios with the net effect method: Domain of validity. Diabetes Technol. Ther. 2016, 18, 694–704.
-
(2016)
Diabetes Technol. Ther.
, vol.18
, pp. 694-704
-
-
Vettoretti, M.1
Facchinetti, A.2
Sparacino, G.3
Cobelli, C.4
-
51
-
-
84953254272
-
Patient decision-making of CGM sensor driven insulin therapies in type 1 diabetes: In silico assessment
-
Vettoretti, M.; Facchinetti, A.; Sparacino, G.; Cobelli, C. Patient decision-making of CGM sensor driven insulin therapies in type 1 diabetes: In silico assessment. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2015, 2015, 2363–2366.
-
(2015)
Conf. Proc. IEEE Eng. Med. Biol. Soc.
, vol.2015
, pp. 2363-2366
-
-
Vettoretti, M.1
Facchinetti, A.2
Sparacino, G.3
Cobelli, C.4
-
52
-
-
69949146908
-
In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes
-
Kovatchev, B.P.; Breton, M.; Man, C.D.; Cobelli, C. In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes. J. Diabetes Sci. Technol. 2009, 3, 44–55.
-
(2009)
J. Diabetes Sci. Technol.
, vol.3
, pp. 44-55
-
-
Kovatchev, B.P.1
Breton, M.2
Man, C.D.3
Cobelli, C.4
-
53
-
-
84899101145
-
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
-
Man, C.D.; Micheletto, F.; Lv, D.; Breton, M.; Kovatchev, B.; Cobelli, C. The UVA/PADOVA Type 1 Diabetes Simulator: New Features. J. Diabetes Sci. Technol. 2014, 8, 26–34.
-
(2014)
J. Diabetes Sci. Technol.
, vol.8
, pp. 26-34
-
-
Man, C.D.1
Micheletto, F.2
Lv, D.3
Breton, M.4
Kovatchev, B.5
Cobelli, C.6
-
54
-
-
84920842830
-
Circadian variability of insulin sensitivity: Physiological input for in silico artificial pancreas
-
Visentin, R.; Dalla Man, C.; Kudva, Y.C.; Basu, A.; Cobelli, C. Circadian variability of insulin sensitivity: Physiological input for in silico artificial pancreas. Diabetes Technol. Ther. 2015, 17, 1–7.
-
(2015)
Diabetes Technol. Ther.
, vol.17
, pp. 1-7
-
-
Visentin, R.1
Dalla Man, C.2
Kudva, Y.C.3
Basu, A.4
Cobelli, C.5
-
55
-
-
84994831205
-
One-Day Bayesian Cloning of Type 1 Diabetes Subjects: Towards a Single-Day UVA/Padova Type 1 Diabetes Simulator
-
Visentin, R.; Man, C.; Cobelli, C. One-Day Bayesian Cloning of Type 1 Diabetes Subjects: Towards a Single-Day UVA/Padova Type 1 Diabetes Simulator. IEEE Trans. Biomed. Eng. 2016, 63, 2416–2424.
-
(2016)
IEEE Trans. Biomed. Eng.
, vol.63
, pp. 2416-2424
-
-
Visentin, R.1
Man, C.2
Cobelli, C.3
-
56
-
-
84953307112
-
Accuracy of devices for self-monitoring of blood glucose: A stochastic error model
-
Vettoretti, M.; Facchinetti, A.; Sparacino, G.; Cobelli, C. Accuracy of devices for self-monitoring of blood glucose: A stochastic error model. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2015, 2015, 2359–2362.
-
(2015)
Conf. Proc. IEEE Eng. Med. Biol. Soc.
, vol.2015
, pp. 2359-2362
-
-
Vettoretti, M.1
Facchinetti, A.2
Sparacino, G.3
Cobelli, C.4
-
57
-
-
84896857976
-
Modeling the glucose sensor error
-
Facchinetti, A.; Del Favero, S.; Sparacino, G.; Castle, J.R.; Ward, W.K.; Cobelli, C. Modeling the glucose sensor error. IEEE Trans. Biomed. Eng. 2014, 61, 620–629.
-
(2014)
IEEE Trans. Biomed. Eng.
, vol.61
, pp. 620-629
-
-
Facchinetti, A.1
Del Favero, S.2
Sparacino, G.3
Castle, J.R.4
Ward, W.K.5
Cobelli, C.6
-
58
-
-
84948719326
-
Model of glucose sensor error components: Identification and assessment for new Dexcom G4 generation devices
-
Facchinetti, A.; Del Favero, S.; Sparacino, G.; Cobelli, C. Model of glucose sensor error components: Identification and assessment for new Dexcom G4 generation devices. Med. Biol. Eng. Comput. 2015, 53, 1259–1269.
-
(2015)
Med. Biol. Eng. Comput.
, vol.53
, pp. 1259-1269
-
-
Facchinetti, A.1
Del Favero, S.2
Sparacino, G.3
Cobelli, C.4
-
59
-
-
84964253561
-
Modeling Transient Disconnections and Compression Artifacts of Continuous Glucose Sensors
-
Facchinetti, A.; Del Favero, S.; Sparacino, G.; Cobelli, C. Modeling Transient Disconnections and Compression Artifacts of Continuous Glucose Sensors. Diabetes Technol. Ther. 2016, 18, 264–272.
-
(2016)
Diabetes Technol. Ther.
, vol.18
, pp. 264-272
-
-
Facchinetti, A.1
Del Favero, S.2
Sparacino, G.3
Cobelli, C.4
-
60
-
-
84983041989
-
Votes to Recommend Non-Adjunctive Use of Dexcom G5 Mobile CGM
-
FDA Advisory Panel Votes to Recommend Non-Adjunctive Use of Dexcom G5 Mobile CGM. Diabetes Technol. Ther. 2016, 18, 512–516.
-
(2016)
Diabetes Technol. Ther
, vol.18
, pp. 512-516
-
-
Advisory Panel, F.D.A.1
-
61
-
-
85009238102
-
Regulation Catches Up to Reality: Nonadjunctive Use of Continuous Glucose Monitoring Data
-
Edelman, S.V. Regulation Catches Up to Reality: Nonadjunctive Use of Continuous Glucose Monitoring Data. J. Diabetes Sci. Technol. 2016, doi:10.1177/1932296816667749.
-
(2016)
J. Diabetes Sci. Technol.
-
-
Edelman, S.V.1
-
62
-
-
84946417124
-
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
-
Bailey, T.; Bode, B.W.; Christiansen, M.P.; Klaff, L.J.; Alva, S. The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System. Diabetes Technol. Ther. 2015, 17, 787–794.
-
(2015)
Diabetes Technol. Ther.
, vol.17
, pp. 787-794
-
-
Bailey, T.1
Bode, B.W.2
Christiansen, M.P.3
Klaff, L.J.4
Alva, S.5
-
63
-
-
84994553148
-
Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: A multicentre, non-masked, randomised controlled trial
-
Bolinder, J.; Antuna, R.; Geelhoed-Duijvestijn, P.; Kroger, J.; Weitgasser, R. Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: A multicentre, non-masked, randomised controlled trial. Lancet 2016, 388, 2254–2263.
-
(2016)
Lancet
, vol.388
, pp. 2254-2263
-
-
Bolinder, J.1
Antuna, R.2
Geelhoed-Duijvestijn, P.3
Kroger, J.4
Weitgasser, R.5
-
64
-
-
84983041362
-
From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior
-
Acciaroli, G.; Vettoretti, M.; Facchinetti, A.; Sparacino, G.; Cobelli, C. From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior. Diabetes Technol. Ther. 2016, 18, 472–479.
-
(2016)
Diabetes Technol. Ther.
, vol.18
, pp. 472-479
-
-
Acciaroli, G.1
Vettoretti, M.2
Facchinetti, A.3
Sparacino, G.4
Cobelli, C.5
-
65
-
-
84940937352
-
Fault detection and safety in closed-loop artificial pancreas systems
-
Bequette, B.W. Fault detection and safety in closed-loop artificial pancreas systems. J. Diabetes Sci. Technol. 2014, 8, 1204–1214.
-
(2014)
J. Diabetes Sci. Technol.
, vol.8
, pp. 1204-1214
-
-
Bequette, B.W.1
|