Volumn 15, Issue 10, 2013, Pages 825-835

A multistep algorithm for processing and calibration of microdialysis continuous glucose monitoring data

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE;

EID: 84884566476     PISSN: 15209156     EISSN: 15578593     Source Type: Journal    
DOI: 10.1089/dia.2013.0041     Document Type: Article
Times cited : (25)

References (53)
  • 1
    • 84864870066 scopus 로고    scopus 로고
    • Characteristics associated with poor glycemic control among adults with self-reported diagnosed diabetes-National Health and Nutrition Examination Survey United States 2007-2010
    • Division of Diabetes Translation National Center for Chronic Disease Prevention and Health Promotion
    • Ali MK, Bullard KM, Imperatore G, Barker L, Gregg EW; Division of Diabetes Translation, National Center for Chronic Disease Prevention and Health Promotion: Characteristics associated with poor glycemic control among adults with self-reported diagnosed diabetes-National Health and Nutrition Examination Survey, United States, 2007-2010. MMWR Surveill Summ 2012;61:32-37.
    • (2012) MMWR Surveill Summ , vol.61 , pp. 32-37
    • Ali, M.K.1    Bullard, K.M.2    Imperatore, G.3    Barker, L.4    Gregg, E.W.5
  • 2
    • 0027286787 scopus 로고
    • Meta-analysis of effects of intensive blood-glucose control on late complications of type I diabetes
    • DOI 10.1016/0140-6736(93)90816-Y
    • Wang PH, Lau J, Chalmers TC: Meta-analysis of effects of intensive blood-glucose control on late complications of type I diabetes. Lancet 1993;341:1306-1309. (Pubitemid 23148093)
    • (1993) Lancet , vol.341 , Issue.8856 , pp. 1306-1309
    • Wang, P.H.1    Lau, J.2    Chalmers, T.C.3
  • 3
    • 84861882779 scopus 로고    scopus 로고
    • Management of diabetic foot ulcers
    • Alexiadou K, Doupis J: Management of diabetic foot ulcers. Diabetes Ther 2012;3:4.
    • (2012) Diabetes Ther , vol.3 , pp. 4
    • Alexiadou, K.1    Doupis, J.2
  • 4
    • 82955235610 scopus 로고    scopus 로고
    • Accuracy of a portable glucose meter and of a continuous glucose monitoring device used at home by patients with type 1 diabetes
    • Francescato MP, Geat M, Stel G, Cauci S: Accuracy of a portable glucose meter and of a continuous glucose monitoring device used at home by patients with type 1 diabetes. Clin Chim Acta 2012;413:312-318.
    • (2012) Clin Chim Acta , vol.413 , pp. 312-318
    • Francescato, M.P.1    Geat, M.2    Stel, G.3    Cauci, S.4
  • 5
    • 84858075765 scopus 로고    scopus 로고
    • The effect of short-term use of the guardian RT continuous glucose monitoring system on fear of hypoglycaemia in patients with type 1 diabetes mellitus
    • Davey RJ, Stevens K, Jones TW, Fournier PA: The effect of short-term use of the guardian RT continuous glucose monitoring system on fear of hypoglycaemia in patients with type 1 diabetes mellitus. Prim Care Diabetes 2012;6: 35-39.
    • (2012) Prim Care Diabetes , vol.6 , pp. 35-39
    • Davey, R.J.1    Stevens, K.2    Jones, T.W.3    Fournier, P.A.4
  • 7
    • 80052002951 scopus 로고    scopus 로고
    • Increasing the low-glucose alarm of a continuous glucose monitoring system prevents exercise-induced hypoglycemia without triggering any false alarms
    • Iscoe KE, Davey RJ, Fournier PA: Increasing the low-glucose alarm of a continuous glucose monitoring system prevents exercise-induced hypoglycemia without triggering any false alarms. Diabetes Care 2011;34:e109.
    • (2011) Diabetes Care , vol.34
    • Iscoe, K.E.1    Davey, R.J.2    Fournier, P.A.3
  • 9
    • 84859040091 scopus 로고    scopus 로고
    • A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to 10 years
    • Mauras N, Beck R, Xing D, Ruedy K, Buckingham B, Tansey M, White NH, Weinzimer SA, Tamborlane W, Kollman C: A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to
    • (2012) Diabetes Care , vol.35 , pp. 204-211
    • Mauras, N.1    Beck, R.2    Xing, D.3    Ruedy, K.4    Buckingham, B.5    Tansey, M.6    White, N.H.7    Weinzimer, S.A.8    Tamborlane, W.9    Kollman, C.10
  • 10
    • 78650269743 scopus 로고    scopus 로고
    • Estimating plasma glucose from interstitial glucose: The issue of calibration algorithms in commercial continuous glucose monitoring devices
    • Rossetti P, Bondia J, Vehi J, Fanelli CG: Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices. Sensors (Basel) 2010;10:10936-10952.
    • (2010) Sensors (Basel) , vol.10 , pp. 10936-10952
    • Rossetti, P.1    Bondia, J.2    Vehi, J.3    Fanelli, C.G.4
  • 11
    • 84855461899 scopus 로고    scopus 로고
    • A multiple local models approach to accuracy improvement in continuous glucose monitoring
    • Barceló Rico F, Bondia J, D́ez JL, Rossetti P: A multiple local models approach to accuracy improvement in continuous glucose monitoring. Diabetes Technol Ther 2012;14:74-82.
    • (2012) Diabetes Technol Ther , vol.14 , pp. 74-82
    • Barceló Rico, F.1    Bondia, J.2    D́ez, J.L.3    Rossetti, P.4
  • 12
    • 77951129243 scopus 로고    scopus 로고
    • Enhanced accuracy of continuous glucose monitoring by online extended Kalman filtering
    • Facchinetti A, Sparacino G, Cobelli C: Enhanced accuracy of continuous glucose monitoring by online extended Kalman filtering. Diabetes Technol Ther 2010;12:353-363.
    • (2010) Diabetes Technol Ther , vol.12 , pp. 353-363
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 13
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman filter for continuous glucose monitoring
    • DOI 10.1089/dia.2005.7.15
    • Knobbe EJ, Buckingham B: The extended Kalman filter for continuous glucose monitoring. Diabetes Technol Ther 2005;7:15-27. (Pubitemid 40354573)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.1 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 16
    • 44849086357 scopus 로고    scopus 로고
    • Putative delays in interstitial fluid (ISF) glucose kinetics can be attributed to the glucose sensing systems used to measure them rather than the delay in ISF glucose itself
    • Voskanyan G, Keenan DB, Mastrototaro JJ, Steil GM: Putative delays in interstitial fluid (ISF) glucose kinetics can be attributed to the glucose sensing systems used to measure them rather than the delay in ISF glucose itself. J Diabetes Sci Technol 2007;1:639-644.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 639-644
    • Voskanyan, G.1    Keenan, D.B.2    Mastrototaro, J.J.3    Steil, G.M.4
  • 17
    • 77953066924 scopus 로고    scopus 로고
    • Delays in minimally invasive continuous glucose monitoring devices: A review of current technology
    • Keenan DB, Mastrototaro JJ, Voskanyan G, Steil GM: Delays in minimally invasive continuous glucose monitoring devices: a review of current technology. J Diabetes Sci Technol 2009;3:1207-1214.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 1207-1214
    • Keenan, D.B.1    Mastrototaro, J.J.2    Voskanyan, G.3    Steil, G.M.4
  • 18
    • 20044380573 scopus 로고    scopus 로고
    • Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex
    • DOI 10.2337/diabetes.54.6.1635
    • Nielsen JK, Djurhuus CB, Gravholt CH, Carus AC, Granild-Jensen J, Orskov H, Christiansen JS: Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex. Diabetes 2005;54:1635-1639. (Pubitemid 40770752)
    • (2005) Diabetes , vol.54 , Issue.6 , pp. 1635-1639
    • Nielsen, J.K.1    Djurhuus, C.B.2    Gravholt, C.H.3    Carus, A.C.4    Granild-Jensen, J.5    Orskov, H.6    Christiansen, J.S.7
  • 20
    • 33845493285 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Key challenges to replacing episodic SMBG
    • DOI 10.1016/S0168-8227(06)70007-9, PII S0168822706700079
    • Stout PJ, Racchini JR, Hilgers ME, Noujaim SE: Continuous glucose monitoring: key challenges to replacing episodic SMBG. Diabetes Res Clin Pract 2006;74(Suppl 2):S97-S100. (Pubitemid 44917745)
    • (2006) Diabetes Research and Clinical Practice , vol.74 , Issue.SUPPL. 2
    • Stout, P.J.1    Racchini, J.R.2    Hilgers, M.E.3    Noujaim, S.E.4
  • 21
    • 44249099753 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring shows a close correlation between mean glucose and time spent in hyperglycemia and hemoglobin A1c
    • Nielsen JK, Gravholt CH, Djurhuus CB, Brandt D, Becker J, Heinemann L, Christiansen JS: Continuous subcutaneous glucose monitoring shows a close correlation between mean glucose and time spent in hyperglycemia and hemoglobin A1c. J Diabetes Sci Technol 2007;1:857-863.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 857-863
    • Nielsen, J.K.1    Gravholt, C.H.2    Djurhuus, C.B.3    Brandt, D.4    Becker, J.5    Heinemann, L.6    Christiansen, J.S.7
  • 22
    • 31144461926 scopus 로고    scopus 로고
    • Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: Mathematical methods and clinical application
    • DOI 10.1089/dia.2005.7.849
    • Kovatchev BP, Clarke WL, Breton M, Brayman K, McCall A: Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. Diabetes Technol Ther 2005;7:849-862. (Pubitemid 43133992)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.6 , pp. 849-862
    • Kovatchev, B.P.1    Clarke, W.L.2    Breton, M.3    Brayman, K.4    McCall, A.5
  • 29
    • 78649344157 scopus 로고    scopus 로고
    • Continuous glucose monitoring in subjects with type 1 diabetes: Improvement in accuracy by correcting for background current
    • El Youssef J, Castle JR, Engle JM, Massoud RG, Ward WK: Continuous glucose monitoring in subjects with type 1 diabetes: improvement in accuracy by correcting for background current. Diabetes Technol Ther 2010;12:921-928.
    • (2010) Diabetes Technol Ther , vol.12 , pp. 921-928
    • El Youssef, J.1    Castle, J.R.2    Engle, J.M.3    Massoud, R.G.4    Ward, W.K.5
  • 30
    • 79952201180 scopus 로고    scopus 로고
    • Use of subcutaneous interstitial fluid glucose to estimate blood glucose: Revisiting delay and sensor offset
    • Rebrin K, Sheppard NF Jr, Steil GM: Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset. J Diabetes Sci Technol 2010;4:1087-1098.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 1087-1098
    • Rebrin, K.1    Sheppard Jr., N.F.2    Steil, G.M.3
  • 34
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • DOI 10.2337/diacare.26.8.2405
    • Kulcu E, Tamada JA, Reach G, Potts RO, Lesho MJ: Physiological differences between interstitial glucose and blood glucose measured in human subjects. Diabetes Care 2003;26: 2405-2409. (Pubitemid 36993334)
    • (2003) Diabetes Care , vol.26 , Issue.8 , pp. 2405-2409
    • Kulcu, E.1    Tamada, J.A.2    Reach, G.3    Potts, R.O.4    Lesho, M.J.5
  • 35
    • 77649182178 scopus 로고    scopus 로고
    • Time lag characterization of two continuous glucose monitoring systems
    • Garg SK, Voelmle M, Gottlieb PA: Time lag characterization of two continuous glucose monitoring systems. Diabetes Res Clin Pract 2010;87:348-353.
    • (2010) Diabetes Res Clin Pract , vol.87 , pp. 348-353
    • Garg, S.K.1    Voelmle, M.2    Gottlieb, P.A.3
  • 36
    • 62249151783 scopus 로고    scopus 로고
    • Graphical and numerical evaluation of continuous glucose sensing time lag
    • Kovatchev BP, Shields D, Breton M: Graphical and numerical evaluation of continuous glucose sensing time lag. Diabetes Technol Ther 2009;11:139-143.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 139-143
    • Kovatchev, B.P.1    Shields, D.2    Breton, M.3
  • 38
    • 79551512124 scopus 로고    scopus 로고
    • Variable time-delay estimation for anesthesia control during intensive care
    • Ionescu CM, Hodrea R, De Keyser R: Variable time-delay estimation for anesthesia control during intensive care. IEEE Trans Biomed Eng 2011;58:363-369.
    • (2011) IEEE Trans Biomed Eng , vol.58 , pp. 363-369
    • Ionescu, C.M.1    Hodrea, R.2    De Keyser, R.3
  • 39
    • 8744299599 scopus 로고    scopus 로고
    • Optimal estimation application to continuous glucose monitoring
    • Boston, MA: American Automatic Control Council
    • Bequette BW: Optimal estimation application to continuous glucose monitoring. In: Proceedings of the 2004 American Control Conference, Vol. 1 Boston, MA: American Automatic Control Council, 2004:958-962.
    • (2004) Proceedings of the 2004 American Control Conference , vol.1 , pp. 958-962
    • Bequette, B.W.1
  • 40
    • 80052042615 scopus 로고    scopus 로고
    • Online denoising method to handle intraindividual variability of signal-tonoise ratio in continuous glucose monitoring
    • Facchinetti A, Sparacino G, Cobelli C: Online denoising method to handle intraindividual variability of signal-tonoise ratio in continuous glucose monitoring. IEEE Trans Biomed Eng 2011;58:2664-2671.
    • (2011) IEEE Trans Biomed Eng , vol.58 , pp. 2664-2671
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 44
    • 58149389636 scopus 로고    scopus 로고
    • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time
    • Mazze RS, Strock E, Borgman S, Wesley D, Stout P, Racchini J: Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): is CGM ready for real time Diabetes Technol Ther 2009;11: 11-18.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 11-18
    • Mazze, R.S.1    Strock, E.2    Borgman, S.3    Wesley, D.4    Stout, P.5    Racchini, J.6
  • 45
    • 34247600583 scopus 로고    scopus 로고
    • Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: Comparison with frequent laboratory reference measurements
    • DOI 10.2337/dc06-1602
    • Weinstein RL, Schwartz SL, Brazg RL, Bugler JR, Peyser TA, McGarraugh GV: Accuracy of the 5-day FreeStyle navigator continuous glucose monitoring system comparison with frequent laboratory reference measurements. Diabetes Care 2007;30:1125-1130. (Pubitemid 46684636)
    • (2007) Diabetes Care , vol.30 , Issue.5 , pp. 1125-1130
    • Weinstein, R.L.1    Schwartz, S.L.2    Brazg, R.L.3    Bugler, J.R.4    Peyser, T.A.5    McGarraugh, G.V.6
  • 47
    • 84872538703 scopus 로고    scopus 로고
    • An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects
    • Facchinetti A, Favero SD, Sparacino G, Cobelli C: An online failure detection method of the glucose sensor-insulin pump system: improved overnight safety of type-1 diabetic subjects. IEEE Trans Biomed Eng 2013;60:406-416.
    • (2013) IEEE Trans Biomed Eng , vol.60 , pp. 406-416
    • Facchinetti, A.1    Favero, S.D.2    Sparacino, G.3    Cobelli, C.4
  • 48
    • 77955504672 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms
    • Bequette BW: Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms. J Diabetes Sci Technol 2010;4:404-418.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 404-418
    • Bequette, B.W.1
  • 49
    • 84861658913 scopus 로고    scopus 로고
    • Predicting human subcutaneous glucose concentration in real time: A universal data-driven approach. Conf Proc
    • Lu Y, Rajaraman S, Ward WK, Vigersky RA, Reifman J: Predicting human subcutaneous glucose concentration in real time: A universal data-driven approach. Conf Proc IEEE Eng Med Biol Soc 2011;2011:7945-7948.
    • (2011) IEEE Eng Med Biol Soc , vol.2011 , pp. 7945-7948
    • Lu, Y.1    Rajaraman, S.2    Ward, W.K.3    Vigersky, R.A.4    Reifman, J.5
  • 52
    • 84861405223 scopus 로고    scopus 로고
    • Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolution-based approach
    • Guerra S, Facchinetti A, Sparacino G, Nicolao GD, Cobelli C: Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach. IEEE Trans Biomed Eng 2012;59:1658-1569.
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 1658-1569
    • Guerra, S.1    Facchinetti, A.2    Sparacino, G.3    Nicolao, G.D.4    Cobelli, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.