LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors

Author keywords

Continuous glucose measurement; diabetes; sensor recalibration

Indexed keywords

CALIBRATION; CONVEX OPTIMIZATION; GLUCOSE; LINEAR MATRIX INEQUALITIES; MEDICAL PROBLEMS;

EID: 84941091951     PISSN: 21682194     EISSN: 21682208     Source Type: Journal    
DOI: 10.1109/JBHI.2014.2341703     Document Type: Article
Times cited : (13)

References (28)
  • 1
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    • Dec.
    • D. Deiss, J. Bolinder, J.-P. Riveline, T. Battelino, E. Bosi, N. Tubiana-Rufi, D. Kerr, and M. Phillip, "Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring," Diabetes Care, vol. 29, no. 12, pp. 2730-2733, Dec. 2006.
    • (2006) Diabetes Care , vol.29 , Issue.12 , pp. 2730-2733
    • Deiss, D.1    Bolinder, J.2    Riveline, J.-P.3    Battelino, T.4    Bosi, E.5    Tubiana-Rufi, N.6    Kerr, D.7    Phillip, M.8
  • 2
    • 78650760751 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • B. Kovatchev,L. Heinemann, S. Anderson, andW. Clarke, "Comparison of the numerical and clinical accuracy of four continuous glucose monitors," Diabetes Care, vol. 31, no. 6, pp. 1160-1164, 2008.
    • (2008) Diabetes Care , vol.31 , Issue.6 , pp. 1160-1164
    • Kovatchev, B.1    Heinemann, L.2    Anderson, S.3    Clarke, W.4
  • 3
    • 84875805117 scopus 로고    scopus 로고
    • System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to din en iso 15197
    • G. Freckmann, C. Schmid, K. Ruhland, A. Baumstark, and C. Haug, "System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to din en iso 15197," J. Diabetes Sci. Technol., vol. 6, no. 5, pp. 1060-1075, 2012.
    • (2012) J. Diabetes Sci. Technol. , vol.6 , Issue.5 , pp. 1060-1075
    • Freckmann, G.1    Schmid, C.2    Ruhland, K.3    Baumstark, A.4    Haug, C.5
  • 4
    • 84889635916 scopus 로고    scopus 로고
    • Performance evaluation of three continuous glucose monitoring systems: Comparison of six sensors per subject in parallel
    • G. Freckmann, S. Pleus, M. Link, E. Zschornack, H.-M. Klötzer, and C. Haug, "Performance evaluation of three continuous glucose monitoring systems: Comparison of six sensors per subject in parallel," J. Diabetes Sci. Technol., vol. 7, no. 4, pp. 842-853, 2013.
    • (2013) J. Diabetes Sci. Technol. , vol.7 , Issue.4 , pp. 842-853
    • Freckmann, G.1    Pleus, S.2    Link, M.3    Zschornack, E.4    Klötzer, H.-M.5    Haug, C.6
  • 5
    • 50049129722 scopus 로고    scopus 로고
    • Clinical application of emerging sensor technologies in diabetes management: Consensus guidelines for continuous glucose monitoring (cgm)
    • I. B. Hirsch, D. Armstrong, R. M. Bergenstal, B. Buckingham, B. Childs, W. L. Clarke, and A. Peters, "Clinical application of emerging sensor technologies in diabetes management: Consensus guidelines for continuous glucose monitoring (cgm)," Diabetes Technol. Therapeutics, vol. 10, no. 4, pp. 232-244, 2008.
    • (2008) Diabetes Technol. Therapeutics , vol.10 , Issue.4 , pp. 232-244
    • Hirsch, I.B.1    Armstrong, D.2    Bergenstal, R.M.3    Buckingham, B.4    Childs, B.5    Clarke, W.L.6    Peters, A.7
  • 7
    • 40449109054 scopus 로고    scopus 로고
    • Electrocemical glucose biosensors
    • J. Wang, "Electrocemical glucose biosensors," Chemical Rev., vol. 108, no. 2, pp. 814-825, 2008.
    • (2008) Chemical Rev. , vol.108 , Issue.2 , pp. 814-825
    • Wang, J.1
  • 8
    • 0042018757 scopus 로고    scopus 로고
    • Continuous glucose monitoring with glucose sensors: Calibration and assessment criteria
    • V. Lodwig and L. Heinemann, "Continuous glucose monitoring with glucose sensors: calibration and assessment criteria," Diabetes Technol. Therapeutics, vol. 5, no. 4, pp. 572-586, 2003.
    • (2003) Diabetes Technol. Therapeutics , vol.5 , Issue.4 , pp. 572-586
    • Lodwig, V.1    Heinemann, L.2
  • 9
    • 78650269743 scopus 로고    scopus 로고
    • Estimating plasma glucose from interstitial glucose: The issue of calibration algorithms in commercial continuous glucose monitoring devices
    • P. Rossetti, J. Bondia, J. Vehi, and C. G. Fanelli, "Estimating plasma glucose from interstitial glucose: The issue of calibration algorithms in commercial continuous glucose monitoring devices," Sensors, vol. 10, pp. 10 936-10 952, 2010.
    • (2010) Sensors , vol.10 , pp. 10936-10952
    • Rossetti, P.1    Bondia, J.2    Vehi, J.3    Fanelli, C.G.4
  • 12
    • 84861405223 scopus 로고    scopus 로고
    • Enhancing the accuracy of subcutaneous glucose sensors: A realtime deconvolution-based approach
    • Jun.
    • S. Guerra, A. Facchinetti, G. Sparacino, G. De Nicolao, and C. Cobelli, "Enhancing the accuracy of subcutaneous glucose sensors: A realtime deconvolution-based approach," IEEE Trans. Biomed. Eng., vol. 59, no. 6, pp. 1658-1669, Jun. 2012.
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , Issue.6 , pp. 1658-1669
    • Guerra, S.1    Facchinetti, A.2    Sparacino, G.3    De Nicolao, G.4    Cobelli, C.5
  • 13
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • M. S. Boyne, D. M. Silver, J. Kaplan, and C. D. Saudek, "Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor," Diabetes, vol. 52, no. 11, pp. 2790-2794, 2003.
    • (2003) Diabetes , vol.52 , Issue.11 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 14
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Sep.
    • K. Rebrin, G. Steil,W. Van Antwerp, and J. Mastrototaro, " Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring," Amer. J. Physiol.-Endocrinol. Metabolism, vol. 277, no. 3, pp. E561-E571, Sep. 1999.
    • (1999) Amer. J. Physiol.-Endocrinol. Metabolism , vol.277 , Issue.3 , pp. E561-E571
    • Rebrin, K.1    Steil, G.2    Van Antwerp, W.3    Mastrototaro, J.4
  • 15
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman filter for continuous glucose monitoring
    • E. J. Knobbe and B. Buckingham, "The extended Kalman filter for continuous glucose monitoring," Diabetes Technol. Therapeutics, vol. 7, no. 1, pp. 15-27, 2005.
    • (2005) Diabetes Technol. Therapeutics , vol.7 , Issue.1 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 16
    • 73949126778 scopus 로고    scopus 로고
    • Analysis, modeling, and simulation of the accuracy of continuous glucose sensors
    • M. D. Breton and B. Kovatchev, "Analysis, modeling, and simulation of the accuracy of continuous glucose sensors," J. Diabetes Sci. Technol., vol. 2, no. 5, pp. 853-862, 2008.
    • (2008) J. Diabetes Sci. Technol. , vol.2 , Issue.5 , pp. 853-862
    • Breton, M.D.1    Kovatchev, B.2
  • 17
    • 77955504672 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms
    • B. W. Bequette, "Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms," J. Diabetes Sci. Technol., vol. 4, no. 2, pp. 404-418, 2010.
    • (2010) J. Diabetes Sci. Technol. , vol.4 , Issue.2 , pp. 404-418
    • Bequette, B.W.1
  • 18
    • 77951129243 scopus 로고    scopus 로고
    • Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering
    • A. Facchinetti, G. Sparacino, and C. Cobelli. (2010). Enhanced accuracy of continuous glucose monitoring by online extended Kalman filtering. Diabetes Technol. Therapeutics [Online]. 12(5), pp. 353-363. Available: http://www. liebertonline. com/doi/abs/10. 1089/dia. 2009. 0158
    • (2010) Diabetes Technol. Therapeutics , vol.12 , Issue.5 , pp. 353-363
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 19
    • 84885133053 scopus 로고    scopus 로고
    • Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring
    • May
    • F. Barcelo-Rico, J.-L. Diez, P. Rosetti, J. Vehi, and J. Bondia, "Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring," IEEE J. Biomed. Health Informat., vol. 17, no. 3, pp. 530-538, May 2013.
    • (2013) IEEE J. Biomed. Health Informat. , vol.17 , Issue.3 , pp. 530-538
    • Barcelo-Rico, F.1    Diez, J.-L.2    Rosetti, P.3    Vehi, J.4    Bondia, J.5
  • 20
    • 79959756904 scopus 로고    scopus 로고
    • Extrapolation in variable RKHs with application to the blood glucose reading
    • Jul.
    • V. Naumova, S. V. Pereverzyev, and S. Sivananthan, "Extrapolation in variable RKHs with application to the blood glucose reading," Inverse Problems, vol. 27, no. 7, Jul. 2011.
    • (2011) Inverse Problems , vol.27 , Issue.7
    • Naumova, V.1    Pereverzyev, S.V.2    Sivananthan, S.3
  • 21
    • 80052042615 scopus 로고    scopus 로고
    • Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring
    • Sep.
    • A. Facchinetti, G. Sparacino, and C. Cobelli, "Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring," IEEE Trans. Biomed. Eng., vol. 58, no. 9, pp. 2664-2671, Sep. 2011.
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.9 , pp. 2664-2671
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 22
    • 84886547493 scopus 로고    scopus 로고
    • A novel online recalibration strategy for continuous glucose measurement sensors employing LMI techniques
    • Jul.
    • H. Kirchsteiger, L. Zaccarian, E. Renard, and L. Del Re, "A novel online recalibration strategy for continuous glucose measurement sensors employing LMI techniques," in Proc. 35th Annu. IEEE EMBC Conf., Jul. 2013, pp. 3921-3924.
    • (2013) Proc. 35th Annu. IEEE EMBC Conf. , pp. 3921-3924
    • Kirchsteiger, H.1    Zaccarian, L.2    Renard, E.3    Del Re, L.4
  • 24
    • 0027474090 scopus 로고
    • On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
    • E. F. Pfeiffer, C. Meyerhoff, F. Bischof, F. S. Keck, and W. Kerner, "On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis," Hormone Metabolic Res., vol. 25, no. 2, pp. 121-124, 1993.
    • (1993) Hormone Metabolic Res. , vol.25 , Issue.2 , pp. 121-124
    • Pfeiffer, E.F.1    Meyerhoff, C.2    Bischof, F.3    Keck, F.S.4    Kerner, W.5
  • 25
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • Aug.
    • E. Kulcu, J. A. Tamada, G. Reach, R. O. Potts, and M. J. Lesho, "Physiological differences between interstitial glucose and blood glucose measured in human subjects," Diabetes Care, vol. 26, no. 8, pp. 2405-2419, Aug. 2003.
    • (2003) Diabetes Care , vol.26 , Issue.8 , pp. 2405-2419
    • Kulcu, E.1    Tamada, J.A.2    Reach, G.3    Potts, R.O.4    Lesho, M.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.