메뉴 건너뛰기




Volumn 7, Issue 5, 2013, Pages 1308-1318

Signal processing algorithms implementing the "smart sensor" concept to improve continuous glucose monitoring in diabetes

Author keywords

Continuous glucose monitoring; Denoising; Filtering; Prediction; Sensor calibration

Indexed keywords

GLUCOSE;

EID: 84900524344     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681300700522     Document Type: Article
Times cited : (12)

References (58)
  • 1
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • Klonof DC. Continuous glucose monitoring: Roadmap for 21st century diabetes therapy. Diabetes Care. 2005;28(5):1231-9.
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonof, D.C.1
  • 2
    • 70349240853 scopus 로고    scopus 로고
    • The chemistry of commercial continuous glucose monitors
    • McGarraugh G. The chemistry of commercial continuous glucose monitors. Diabetes Technol Ther. 2009;11 Suppl 1:S17-24.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • McGarraugh, G.1
  • 3
    • 69249106968 scopus 로고    scopus 로고
    • An overview of continuous glucose monitoring systems
    • Cox M. An overview of continuous glucose monitoring systems. J Pediatr Health Care. 2009;23(5):344-7.
    • (2009) J Pediatr Health Care , vol.23 , Issue.5 , pp. 344-347
    • Cox, M.1
  • 4
    • 84862177050 scopus 로고    scopus 로고
    • Personal continuous glucose monitoring (CGM) in diabetes management: Review of the literature and implementation for practical use
    • Joubert M, Reznik Y. Personal continuous glucose monitoring (CGM) in diabetes management: review of the literature and implementation for practical use. Diabetes Res Clin Pract. 2012;96(3):294-305.
    • (2012) Diabetes Res Clin Pract , vol.96 , Issue.3 , pp. 294-305
    • Joubert, M.1    Reznik, Y.2
  • 5
    • 84868251461 scopus 로고    scopus 로고
    • Italian contributions to the development of continuous glucose monitoring sensors for diabetes management
    • Basel
    • Sparacino G, Zanon M, Facchinetti A, Zecchin C, Maran A, Cobelli C. Italian contributions to the development of continuous glucose monitoring sensors for diabetes management. Sensors (Basel). 2012;12(10):13753-80.
    • (2012) Sensors , vol.12 , Issue.10 , pp. 13753-13780
    • Sparacino, G.1    Zanon, M.2    Facchinetti, A.3    Zecchin, C.4    Maran, A.5    Cobelli, C.6
  • 7
    • 80055050523 scopus 로고    scopus 로고
    • Glycemic variability: Measurement and utility in clinical medicine and research - One viewpoint
    • Rodbard D. Glycemic variability: measurement and utility in clinical medicine and research - one viewpoint. Diabetes Technol Ther. 2011;13(11):1077-80.
    • (2011) Diabetes Technol Ther , vol.13 , Issue.11 , pp. 1077-1080
    • Rodbard, D.1
  • 8
    • 62249131539 scopus 로고    scopus 로고
    • Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System
    • McGarraugh G, Bergenstal R. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. Diabetes Technol Ther. 2009;11(3):145-50.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.3 , pp. 145-150
    • McGarraugh, G.1    Bergenstal, R.2
  • 9
    • 84872192562 scopus 로고    scopus 로고
    • Reduction of number and duration of hypoglycemic events by glucose prediction methods: A proof-of-concept in silico study
    • Zecchin C, Facchinetti A, Sparacino G, Cobelli C. Reduction of number and duration of hypoglycemic events by glucose prediction methods: a proof-of-concept in silico study. Diabetes Technol Ther. 2013;15(1):66-77.
    • (2013) Diabetes Technol Ther , vol.15 , Issue.1 , pp. 66-77
    • Zecchin, C.1    Facchinetti, A.2    Sparacino, G.3    Cobelli, C.4
  • 10
    • 79952197615 scopus 로고    scopus 로고
    • Hypoglycemia prevention via pump attenuation and red-yellow-green "trafic" lights using continuous glucose monitoring and insulin pump data
    • Hughes CS, Patek SD, Breton MD, Kovatchev BP. Hypoglycemia prevention via pump attenuation and red-yellow-green "trafic" lights using continuous glucose monitoring and insulin pump data. J Diabetes Sci Technol. 2010;4(5):1146-55.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.5 , pp. 1146-1155
    • Hughes, C.S.1    Patek, S.D.2    Breton, M.D.3    Kovatchev, B.P.4
  • 14
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care. 2008;31(5):934-9.
    • (2008) Diabetes Care , vol.31 , Issue.5 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3    Dziura, J.4    Kurtz, N.5    Tamborlane, W.V.6
  • 21
    • 77951121063 scopus 로고    scopus 로고
    • Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings
    • McGarraugh GV, Clarke WL, Kovatchev BP. Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings. Diabetes Technol Ther. 2010;12(5):365-71
    • (2010) Diabetes Technol Ther , vol.12 , Issue.5 , pp. 365-371
    • McGarraugh, G.V.1    Clarke, W.L.2    Kovatchev, B.P.3
  • 24
    • 77957127872 scopus 로고    scopus 로고
    • "Smart" continuous glucose monitoring sensors: On-line signal processing issues
    • Basel
    • Sparacino G, Facchinetti A, Cobelli C. "Smart" continuous glucose monitoring sensors: on-line signal processing issues. Sensors (Basel). 2010;10(7):6751-72.
    • (2010) Sensors , vol.10 , Issue.7 , pp. 6751-6772
    • Sparacino, G.1    Facchinetti, A.2    Cobelli, C.3
  • 25
    • 77955504672 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms
    • Bequette BW. Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms. J Diabetes Sci Technol. 2010;4(2):404-18.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.2 , pp. 404-418
    • Bequette, B.W.1
  • 27
    • 77649150209 scopus 로고    scopus 로고
    • An online self-tunable method to denoise CGM sensor data
    • Facchinetti A, Sparacino G, Cobelli C. An online self-tunable method to denoise CGM sensor data. IEEE Trans Biomed Eng. 2010;57(3):634-41.
    • (2010) IEEE Trans Biomed Eng , vol.57 , Issue.3 , pp. 634-641
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 28
    • 80052042615 scopus 로고    scopus 로고
    • Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring
    • Facchinetti A, Sparacino G, Cobelli C. Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring. IEEE Trans Biomed Eng. 2011;58(9):2664-71.
    • (2011) IEEE Trans Biomed Eng , vol.58 , Issue.9 , pp. 2664-2671
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 30
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman filter for continuous glucose monitoring
    • DOI 10.1089/dia.2005.7.15
    • Knobbe EJ, Buckingham B. The extended Kalman filter for continuous glucose monitoring. Diabetes Technol Ther. 2005;7(1):15-27. (Pubitemid 40354573)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.1 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 31
    • 77951129243 scopus 로고    scopus 로고
    • Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering
    • Facchinetti A, Sparacino G, Cobelli C. Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering. Diabetes Technol Ther. 2010;12(5):353-63.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.5 , pp. 353-363
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 32
    • 78650269743 scopus 로고    scopus 로고
    • Estimating plasma glucose from interstitial glucose: The issue of calibration algorithms in commercial continuous glucose monitoring devices
    • Basel
    • Rossetti P, Bondia J, Vehí J, Fanelli CG. Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices. Sensors (Basel). 2010;10(12):10936-52.
    • (2010) Sensors , vol.10 , Issue.12 , pp. 10936-10952
    • Rossetti, P.1    Bondia, J.2    Vehí, J.3    Fanelli, C.G.4
  • 33
    • 84855461899 scopus 로고    scopus 로고
    • A multiple local models approach to accuracy improvement in continuous glucose monitoring
    • Barceló-Rico F, Bondia J, Díez JL, Rossetti P. A multiple local models approach to accuracy improvement in continuous glucose monitoring. Diabetes Technol Ther. 2012;14(1):74-82
    • (2012) Diabetes Technol Ther , vol.14 , Issue.1 , pp. 74-82
    • Barceló-Rico, F.1    Bondia, J.2    Díez, J.L.3    Rossetti, P.4
  • 34
    • 77954672554 scopus 로고    scopus 로고
    • Methods of evaluating the utility of continuous glucose monitor alerts
    • Kamath A, Mahalingam A, Brauker J. Methods of evaluating the utility of continuous glucose monitor alerts. J Diabetes Sci Technol. 2010;4(1):57-66.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.1 , pp. 57-66
    • Kamath, A.1    Mahalingam, A.2    Brauker, J.3
  • 36
    • 84861405223 scopus 로고    scopus 로고
    • Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolutionbased approach
    • Guerra S, Facchinetti A, Sparacino G, Nicolao GD, Cobelli C. Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolutionbased approach. IEEE Trans Biomed Eng. 2012;59(6):1658-69.
    • (2012) IEEE Trans Biomed Eng , vol.59 , Issue.6 , pp. 1658-1669
    • Guerra, S.1    Facchinetti, A.2    Sparacino, G.3    Nicolao, G.D.4    Cobelli, C.5
  • 38
    • 79955524199 scopus 로고    scopus 로고
    • A Bayesian method to estimate single-trial event-related potentials with application to the study of the P300 variability
    • D'Avanzo C, Schif S, Amodio P, Sparacino G. A Bayesian method to estimate single-trial event-related potentials with application to the study of the P300 variability. J Neurosci Methods. 2011;198(1):114-24.
    • (2011) J Neurosci Methods , vol.198 , Issue.1 , pp. 114-124
    • D'Avanzo, C.1    Schif, S.2    Amodio, P.3    Sparacino, G.4
  • 40
    • 0031130574 scopus 로고    scopus 로고
    • Nonparametric input estimation in physiological systems: Problems, methods, and case studies
    • PII S0005109896002543
    • De Nicolao G, Sparacino G, Cobelli C. Nonparametric input estimation in physiological systems: problems, methods and case studies. Automatica. 1997;33(5):851-70. (Pubitemid 127413702)
    • (1997) Automatica , vol.33 , Issue.5 , pp. 851-870
    • De Nicolao, G.1    Sparacino, G.2    Cobelli, C.3
  • 41
    • 0030152634 scopus 로고    scopus 로고
    • A stochastic deconvolution method to reconstruct insulin secretion rate after a glucose stimulus
    • DOI 10.1109/10.488799
    • Sparacino G, Cobelli C. A stochastic deconvolution method to reconstruct insulin secretion rate after a glucose stimulus. IEEE Trans Biomed Eng. 1996;43(5):512-29. (Pubitemid 26131473)
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.5 , pp. 512-529
    • Sparacino, G.1    Cobelli, C.2
  • 42
    • 84872538703 scopus 로고    scopus 로고
    • An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects
    • Facchinetti A, Del Favero S, Sparacino G, Cobelli C. An online failure detection method of the glucose sensor-insulin pump system: improved overnight safety of type-1 diabetic subjects. IEEE Trans Biomed Eng. 2013;60(2):406-16.
    • (2013) IEEE Trans Biomed Eng , vol.60 , Issue.2 , pp. 406-416
    • Facchinetti, A.1    Del Favero, S.2    Sparacino, G.3    Cobelli, C.4
  • 44
    • 59649089217 scopus 로고    scopus 로고
    • Modeling of calibration efectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp
    • King C, Anderson SM, Breton M, Clarke WL, Kovatchev BP. Modeling of calibration efectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp. J Diabetes Sci Technol. 2007;1(3):317-22.
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.3 , pp. 317-322
    • King, C.1    Anderson, S.M.2    Breton, M.3    Clarke, W.L.4    Kovatchev, B.P.5
  • 46
    • 63849301691 scopus 로고    scopus 로고
    • Predicting subcutaneous glucose concentration in humans: Data-driven glucose modeling
    • Gani A, Gribok AV, Rajaraman S, Ward WK, Reifman J. Predicting subcutaneous glucose concentration in humans: data-driven glucose modeling. IEEE Trans Biomed Eng. 2009;56(2):246-54.
    • (2009) IEEE Trans Biomed Eng , vol.56 , Issue.2 , pp. 246-254
    • Gani, A.1    Gribok, A.V.2    Rajaraman, S.3    Ward, W.K.4    Reifman, J.5
  • 49
    • 84861394725 scopus 로고    scopus 로고
    • Neural network incorporating meal information improves accuracy of shorttime prediction of glucose concentration
    • Zecchin C, Facchinetti A, Sparacino G, De Nicolao G, Cobelli C. Neural network incorporating meal information improves accuracy of shorttime prediction of glucose concentration. IEEE Trans Biomed Eng. 2012;59(6):1550-60.
    • (2012) IEEE Trans Biomed Eng , vol.59 , Issue.6 , pp. 1550-1560
    • Zecchin, C.1    Facchinetti, A.2    Sparacino, G.3    De Nicolao, G.4    Cobelli, C.5
  • 50
    • 84863859637 scopus 로고    scopus 로고
    • A meta-learning approach to the regularized learning-case study: Blood glucose prediction
    • Naumova V, Pereverzyev SV, Sivananthan S. A meta-learning approach to the regularized learning-case study: blood glucose prediction. Neural Netw. 2012;33:181-93.
    • (2012) Neural Netw , vol.33 , pp. 181-193
    • Naumova, V.1    Pereverzyev, S.V.2    Sivananthan, S.3
  • 51
    • 84864447817 scopus 로고    scopus 로고
    • Adaptive system identification for estimating future glucose concentrations and hypoglycemia alarms
    • Oxf
    • Eren-Oruklu M, Cinar A, Rollins DK, Quinn L. Adaptive system identification for estimating future glucose concentrations and hypoglycemia alarms. Automatica (Oxf). 2012;48(8):1892-7.
    • (2012) Automatica , vol.48 , Issue.8 , pp. 1892-1897
    • Eren-Oruklu, M.1    Cinar, A.2    Rollins, D.K.3    Quinn, L.4
  • 52
    • 79551580499 scopus 로고    scopus 로고
    • A new index to optimally design and compare continuous glucose monitoring glucose prediction algorithms
    • Facchinetti A, Sparacino G, Trifoglio E, Cobelli C. A new index to optimally design and compare continuous glucose monitoring glucose prediction algorithms. Diabetes Technol Ther. 2011;13(2):111-9.
    • (2011) Diabetes Technol Ther , vol.13 , Issue.2 , pp. 111-119
    • Facchinetti, A.1    Sparacino, G.2    Trifoglio, E.3    Cobelli, C.4
  • 53
    • 84900540682 scopus 로고    scopus 로고
    • EU-FP7 project website. Accessed March 8, 2013
    • AP@home, EU-FP7 project website. http://www.apathome.eu/. Accessed March 8, 2013.
  • 55
    • 78650760751 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W. Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care. 2008;31(6):1160-4.
    • (2008) Diabetes Care , vol.31 , Issue.6 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 57
    • 70349240850 scopus 로고    scopus 로고
    • Statistical tools to analyze continuous glucose monitor data
    • Clarke W, Kovatchev B. Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther. 2009;11 Suppl 1:S45-54.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Clarke, W.1    Kovatchev, B.2
  • 58
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • DOI 10.2337/diacare.27.8.1922
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucoseerror grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care. 2004;27(8):1922-8. (Pubitemid 38989233)
    • (2004) Diabetes Care , vol.27 , Issue.8 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.