메뉴 건너뛰기




Volumn 1, Issue 5, 2007, Pages 624-629

Hypoglycemia detection and prediction using continuous glucose monitoring - A study on hypoglycemic clamp data

Author keywords

Glucose monitoring; Hypoglycemia prediction; Hypoglycemic clamp; Kalman filtering

Indexed keywords


EID: 54749149727     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680700100505     Document Type: Conference Paper
Times cited : (74)

References (11)
  • 1
    • 0036020278 scopus 로고    scopus 로고
    • Hypoglycaemia: The limiting factor in the glycaemic management of type I and type II diabetes
    • Jul.
    • Cryer PE. Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes. Diabetologia. 2002 Jul; 45(7):937-48.
    • (2002) Diabetologia. , vol.45 , Issue.7 , pp. 937-948
    • Cryer, P.E.1
  • 2
    • 0033011704 scopus 로고    scopus 로고
    • Is blood glucose predictable from previous values? A solicitation for data
    • Mar.
    • Bremer T, Gough DA. Is blood glucose predictable from previous values? A solicitation for data. Diabetes. 1999 Mar; 48(3):445-51.
    • (1999) Diabetes. , vol.48 , Issue.3 , pp. 445-451
    • Bremer, T.1    Gough, D.A.2
  • 3
    • 0036830617 scopus 로고    scopus 로고
    • Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system
    • Nov.
    • Choleau C, Dokladal P, Klein J, Ward WK, Wilson GS, Reach G. Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system. Diabetes. 2002 Nov; 51(11):3263-73.
    • (2002) Diabetes. , vol.51 , Issue.11 , pp. 3263-3273
    • Choleau, C.1    Dokladal, P.2    Klein, J.3    Ward, W.K.4    Wilson, G.S.5    Reach, G.6
  • 4
    • 0042519615 scopus 로고    scopus 로고
    • Hypoglycemia warning signal and glucose sensors: Requirements and concepts
    • Glucose Monitoring Study Group
    • Heise T, Koschinsky T, Heinemann L, Lodwig V; Glucose Monitoring Study Group. Hypoglycemia warning signal and glucose sensors: requirements and concepts. Diabetes Technol Ther. 2003;5(4):563-71.
    • (2003) Diabetes Technol Ther. , vol.5 , Issue.4 , pp. 563-571
    • Heise, T.1    Koschinsky, T.2    Heinemann, L.3    Lodwig, V.4
  • 5
    • 1842582980 scopus 로고    scopus 로고
    • The role of new technology in the early detection of hypoglycemia
    • Apr.
    • Ward WK. The role of new technology in the early detection of hypoglycemia. Diabetes Technol Ther. 2004 Apr; 6(2):115-7.
    • (2004) Diabetes Technol Ther. , vol.6 , Issue.2 , pp. 115-117
    • Ward, W.K.1
  • 6
    • 34247372642 scopus 로고    scopus 로고
    • Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series
    • May
    • Sparacino G, Zanderigo F, Corazza S, Maran A, Facchinetti A, Cobelli C. Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series. IEEE Trans Biomed Eng. 2007 May; 54(5):931-7.
    • (2007) IEEE Trans Biomed Eng. , vol.54 , Issue.5 , pp. 931-937
    • Sparacino, G.1    Zanderigo, F.2    Corazza, S.3    Maran, A.4    Facchinetti, A.5    Cobelli, C.6
  • 8
    • 0034533288 scopus 로고    scopus 로고
    • Episodes of severe hypoglycemia in type 1 diabetes are preceded and followed within 48 hours by measurable disturbances in blood glucose
    • Nov.
    • Kovatchev BP, Cox DJ, Farhy LS, Straume M, Gonder-Frederick L, Clarke WL. Episodes of severe hypoglycemia in type 1 diabetes are preceded and followed within 48 hours by measurable disturbances in blood glucose. J Clin Endocrinol Metab. 2000 Nov; 85(11):4287-92.
    • (2000) J Clin Endocrinol Metab. , vol.85 , Issue.11 , pp. 4287-4292
    • Kovatchev, B.P.1    Cox, D.J.2    Farhy, L.S.3    Straume, M.4    Gonder-Frederick, L.5    Clarke, W.L.6
  • 9
    • 0030834435 scopus 로고    scopus 로고
    • Symmetrization of the blood glucose measurement scale and its applications
    • Nov.
    • Kovatchev BP, Cox DJ, Gonder-Frederick LA, Clarke W. Symmetrization of the blood glucose measurement scale and its applications. Diabetes Care. 1997 Nov; 20(11):1655-8.
    • (1997) Diabetes Care. , vol.20 , Issue.11 , pp. 1655-1658
    • Kovatchev, B.P.1    Cox, D.J.2    Gonder-Frederick, L.A.3    Clarke, W.4
  • 10
    • 0031755304 scopus 로고    scopus 로고
    • Assessment of risk for severe hypoglycemia among adults with IDDM: Validation of the low blood glucose index
    • Nov.
    • Kovatchev BP, Cox DJ, Gonder-Frederick LA, Young-Hyman D, Schlundt D, Clarke W. Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index. Diabetes Care. 1998 Nov; 21(11):1870-5.
    • (1998) Diabetes Care. , vol.21 , Issue.11 , pp. 1870-1875
    • Kovatchev, B.P.1    Cox, D.J.2    Gonder-Frederick, L.A.3    Young-Hyman, D.4    Schlundt, D.5    Clarke, W.6
  • 11
    • 31144461926 scopus 로고    scopus 로고
    • Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: Mathematical methods and clinical application
    • Dec.
    • Kovatchev BP, Clarke WL, Breton M, Brayman K, McCall A. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. Diabetes Technol Ther. 2005 Dec; 7(6):849-62.
    • (2005) Diabetes Technol Ther. , vol.7 , Issue.6 , pp. 849-862
    • Kovatchev, B.P.1    Clarke, W.L.2    Breton, M.3    Brayman, K.4    McCall, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.