메뉴 건너뛰기




Volumn 60, Issue 2, 2013, Pages 406-416

An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects

Author keywords

Continuous glucose monitoring (CGM); diabetes; Kalman filter; parameter estimation

Indexed keywords

BLACK-BOX MODEL; CONFIDENCE INTERVAL; CONTINUOUS GLUCOSE MONITORING; DATA STREAM; DIABETIC PATIENT; FAILURE DETECTION METHOD; FALSE NEGATIVES; FALSE POSITIVE; GLUCOSE CONCENTRATION; INSULIN INFUSIONS; KALMAN-FILTERING; OFFLINE; PATIENT SAFETY; PUMP SYSTEM; REAL TIME; REAL-TIME DATA STREAMS; STATE-SPACE MODELS; VIRTUAL PATIENTS;

EID: 84872538703     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2012.2227256     Document Type: Article
Times cited : (57)

References (32)
  • 1
    • 80054057129 scopus 로고    scopus 로고
    • Evolution of devices in diabetes management
    • Jun
    • A. Penfornis, E. Personeni, and S. Borot, "Evolution of devices in diabetes management; Diabetes Technol. Ther., vol. 13 no. suppl. 1, pp. 93-102, Jun. 2011.
    • (2011) Diabetes Technol. Ther , vol.13 , Issue.SUPPL. 1 , pp. 93-102
    • Penfornis, A.1    Personeni, E.2    Borot, S.3
  • 2
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • DOI 10.2337/diacare.28.5.1231
    • D. C. Klonoff, "Continuous glucose monitoring: Roadmap for 21st century diabetes therapy; Diabetes Care, vol. 28, pp. 1231-1239, May 2005. (Pubitemid 40616646)
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 3
    • 69249106968 scopus 로고    scopus 로고
    • An overview of continuous glucose monitoring systems
    • M. Cox, "An overview of continuous glucose monitoring systems; J. Pediatr. Health Care, vol. 23, no. 5, pp. 344-347, 2009.
    • (2009) J. Pediatr. Health Care , vol.23 , Issue.5 , pp. 344-347
    • Cox, M.1
  • 4
    • 70349240853 scopus 로고    scopus 로고
    • The chemistry of commercial continuous glucose monitors
    • Jun
    • G. McGarraugh, "The chemistry of commercial continuous glucose monitors; Diabet. Technol. Ther., vol. 11, no. 1, pp. 17-24, Jun. 2009.
    • (2009) Diabet. Technol. Ther , vol.11 , Issue.1 , pp. 17-24
    • McGarraugh, G.1
  • 5
    • 84862177050 scopus 로고    scopus 로고
    • Personal continuous glucose monitoring (CGM) in diabetes management: Review of the literature and implementation for practical use
    • Dec
    • M. Joubert and Y. Reznik, "Personal continuous glucose monitoring (CGM) in diabetes management: Review of the literature and implementation for practical use; Diabetes Res. Clin. Pract., vol. 96, no. 3, pp. 294-305, Dec. 2011.
    • (2011) Diabetes Res. Clin. Pract , vol.96 , Issue.3 , pp. 294-305
    • Joubert, M.1    Reznik, Y.2
  • 7
    • 84860116942 scopus 로고    scopus 로고
    • Insulin-pump therapy for type 1 diabetes mellitus
    • Apr
    • J. C. Pickup, "Insulin-pump therapy for type 1 diabetes mellitus; N. Engl. J. Med., vol. 366, pp. 1616-1624, Apr. 2012.
    • (2012) N. Engl. J. Med , vol.366 , pp. 1616-1624
    • Pickup, J.C.1
  • 10
    • 54749116015 scopus 로고    scopus 로고
    • The future of continuous glucose monitoring: Closed loop
    • Aug
    • R. Hovorka, "The future of continuous glucose monitoring: Closed loop; Curr. Diabetes Rev., vol. 4, pp. 269-279, Aug. 2008.
    • (2008) Curr. Diabetes Rev , vol.4 , pp. 269-279
    • Hovorka, R.1
  • 12
    • 80755148728 scopus 로고    scopus 로고
    • Artificial pancreas: Past, present, future
    • Nov
    • C. Cobelli, E. Renard, and B. Kovatchev, "Artificial pancreas: Past, present, future; Diabetes, vol. 60, pp. 2672-2682, Nov. 2011.
    • (2011) Diabetes , vol.60 , pp. 2672-2682
    • Cobelli, C.1    Renard, E.2    Kovatchev, B.3
  • 13
    • 78049488149 scopus 로고    scopus 로고
    • Pilot study for assessment of optimal frequency for changing catheters in insulin pump therapy-trouble starts on day 3
    • Jul
    • V. Schmid, C. Hohberg, M. Borchert, T. Forst, and A. Pfutzner, "Pilot study for assessment of optimal frequency for changing catheters in insulin pump therapy-trouble starts on day 3; J. Diabetes Sci. Technol., vol. 4, pp. 976-982, Jul. 2010.
    • (2010) J. Diabetes Sci. Technol , vol.4 , pp. 976-982
    • Schmid, V.1    Hohberg, C.2    Borchert, M.3    Forst, T.4    Pfutzner, A.5
  • 14
    • 84860590392 scopus 로고    scopus 로고
    • Significant time until catheter occlusion alerts in currently marketed insulin pumps at two basal rates
    • May
    • A. C. van Bon, D. Dragt, and J. H. Devries, "Significant time until catheter occlusion alerts in currently marketed insulin pumps at two basal rates; Diabetes Technol. Ther., vol. 14, pp. 447-448, May 2012.
    • (2012) Diabetes Technol. Ther , vol.14 , pp. 447-448
    • Van Bon, A.C.1    Dragt, D.2    Devries, J.H.3
  • 16
    • 84858756238 scopus 로고    scopus 로고
    • Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: Examples and application
    • K. L. Helton, B. D. Ratner, and N. A. Wisniewski, "Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: Examples and application; J. Diabetes Sci. Technol., vol. 5, pp. 647-656, 2011.
    • (2011) J. Diabetes Sci. Technol , vol.5 , pp. 647-656
    • Helton, K.L.1    Ratner, B.D.2    Wisniewski, N.A.3
  • 18
    • 77950062222 scopus 로고    scopus 로고
    • Amperometric glucose sensors: Sources of error and potential benefit of redundancy
    • Jan
    • J. R. Castle and W. K. Ward, "Amperometric glucose sensors: Sources of error and potential benefit of redundancy; J. Diabetes Sci. Technol., vol. 4, pp. 221-225, Jan. 2010.
    • (2010) J. Diabetes Sci. Technol , vol.4 , pp. 221-225
    • Castle, J.R.1    Ward, W.K.2
  • 20
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • Jan
    • R. Hovorka, "Continuous glucose monitoring and closed-loop systems; Diabet. Med., vol. 23, pp. 1-12, Jan. 2006.
    • (2006) Diabet. Med , vol.23 , pp. 1-12
    • Hovorka, R.1
  • 21
    • 14844348762 scopus 로고    scopus 로고
    • Subspace identification of closed loop systems by the orthogonal decomposition method
    • DOI 10.1016/j.automatica.2004.11.026, PII S0005109805000075
    • T. Katayama, H. Kawauchi, and G. Picci, "Subspace identification of closed-loop systems by orthogonal decomposition; Automatica, vol. 41, pp. 863-872, 2005. (Pubitemid 40352400)
    • (2005) Automatica , vol.41 , Issue.5 , pp. 863-872
    • Katayama, T.1    Kawauchi, H.2    Picci, G.3
  • 24
    • 34247372642 scopus 로고    scopus 로고
    • Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series
    • DOI 10.1109/TBME.2006.889774, 21
    • G. Sparacino, F. Zanderigo, S. Corazza, A. Maran, A. Facchinetti, and C. Cobelli, "Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series; IEEE Trans. Biomed. Eng., vol. 54, no. 5, pp. 931-937, May 2007. (Pubitemid 46628560)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.5 , pp. 931-937
    • Sparacino, G.1    Zanderigo, F.2    Corazza, S.3    Maran, A.4    Facchinetti, A.5    Cobelli, C.6
  • 26
    • 76849115431 scopus 로고    scopus 로고
    • Universal glucose models for predicting subcutaneous glucose concentration in humans
    • Jan
    • A. Gani, A. V. Gribok, Y. Lu,W. K.Ward, R. A. Vigersky, and J. Reifman, "Universal glucose models for predicting subcutaneous glucose concentration in humans; IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 1, pp. 157-165, Jan. 2010.
    • (2010) IEEE Trans. Inf. Technol. Biomed , vol.14 , Issue.1 , pp. 157-165
    • Gani, A.1    Gribok, A.V.2    Lu, Y.3    Ward, W.K.4    Vigersky, R.A.5    Reifman, J.6
  • 27
    • 80052042615 scopus 로고    scopus 로고
    • Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring
    • Sep
    • A. Facchinetti, G. Sparacino, and C. Cobelli, "Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring; IEEE Trans. Biomed. Eng., vol. 58, no. 9, pp. 2664- 2671, Sep. 2011.
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , Issue.9 , pp. 2664-2671
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 28
    • 77649150209 scopus 로고    scopus 로고
    • An online self-tunable method to denoise CGM sensor data
    • Mar
    • A. Facchinetti, G. Sparacino, and C. Cobelli, "An online self-tunable method to denoise CGM sensor data; IEEE Trans. Biomed. Eng., vol. 57, no. 3, pp. 634-641, Mar. 2010
    • (2010) IEEE Trans. Biomed. Eng , vol.57 , Issue.3 , pp. 634-641
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 29
    • 33744908804 scopus 로고    scopus 로고
    • Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care
    • DOI 10.1016/j.cmpb.2006.03.004, PII S016926070600068X
    • J. G. Chase, C. E. Hann, M. Jackson, J. Lin, T. Lotz, X. W. Wong, and G. M. Shaw, "Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care; Comput. Method. Progr. Biomed., vol. 82, pp. 238-247, Jun. 2006. (Pubitemid 43850048)
    • (2006) Computer Methods and Programs in Biomedicine , vol.82 , Issue.3 , pp. 238-247
    • Chase, J.G.1    Hann, C.E.2    Jackson, M.3    Lin, J.4    Lotz, T.5    Wong, X.-W.6    Shaw, G.M.7
  • 30
    • 73949126778 scopus 로고    scopus 로고
    • Analysis, modeling, and simulation of the accuracy of continuous glucose sensors
    • Sep
    • M. Breton and B. Kovatchev, "Analysis, modeling, and simulation of the accuracy of continuous glucose sensors; J. Diabet. Sci. Technol., vol. 2, pp. 853-862, Sep. 2008.
    • (2008) J. Diabet. Sci. Technol , vol.2 , pp. 853-862
    • Breton, M.1    Kovatchev, B.2
  • 31
    • 77954668157 scopus 로고    scopus 로고
    • Modeling the error of continuous glucose monitoring sensor data: Critical aspects discussed through simulation studies
    • Jan
    • A. Facchinetti, G. Sparacino, and C. Cobelli, "Modeling the error of continuous glucose monitoring sensor data: Critical aspects discussed through simulation studies; J. Diabet. Sci. Technol., vol. 4, pp. 4-14, Jan. 2010.
    • (2010) J. Diabet. Sci. Technol , vol.4 , pp. 4-14
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.