메뉴 건너뛰기




Volumn 36, Issue 4, 2013, Pages 793-800

Real-time improvement of continuous glucose monitoring accuracy: The smart sensor concept

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ALGORITHM; ARTICLE; BLOOD GLUCOSE MONITORING; CLINICAL ARTICLE; CONTINUOUS GLUCOSE MONITORING; FEMALE; GLUCOSE SENSOR; HUMAN; HYPERGLYCEMIA; HYPOGLYCEMIA; INSULIN DEPENDENT DIABETES MELLITUS; MALE; NOISE REDUCTION; PREDICTION; SIGNAL PROCESSING; TIME SERIES ANALYSIS;

EID: 84875422729     PISSN: 01495992     EISSN: 19355548     Source Type: Journal    
DOI: 10.2337/dc12-0736     Document Type: Article
Times cited : (93)

References (38)
  • 1
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • Klonoff DC. Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 2005;28:1231-1239
    • (2005) Diabetes Care , vol.28 , pp. 1231-1239
    • Klonoff, D.C.1
  • 2
    • 70349240853 scopus 로고    scopus 로고
    • The chemistry of commercial continuous glucose monitors
    • McGarraugh G. The chemistry of commercial continuous glucose monitors. Diabetes Technol Ther 2009;11(Suppl. 1):S17-S24
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • McGarraugh, G.1
  • 3
    • 0242268979 scopus 로고    scopus 로고
    • The accuracy of the CGMS in children with type 1 diabetes: Results of the diabetes research in children network (DirecNet) accuracy study
    • Diabetes Research in Children Network (DIRECNET) Study Group
    • Diabetes Research in Children Network (DIRECNET) Study Group. The accuracy of the CGMS in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study. Diabetes Technol Ther 2003;5: 781-789
    • (2003) Diabetes Technol Ther , vol.5 , pp. 781-789
  • 4
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    • Deiss D, Bolinder J, Riveline JP, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006;29:2730-2732
    • (2006) Diabetes Care , vol.29 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.P.3
  • 6
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucosemonitoring and intensive treatment of type 1 diabetes
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group; Tamborlane WV, Beck RW, Bode BW, et al. Continuous glucosemonitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008;359:1464-1476
    • (2008) N Engl J Med , vol.359 , pp. 1464-1476
    • Tamborlane, W.V.1    Beck, R.W.2    Bode, B.W.3
  • 7
    • 62249131539 scopus 로고    scopus 로고
    • Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System
    • McGarraugh G, Bergenstal R. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. Diabetes Technol Ther 2009;11:145-150
    • (2009) Diabetes Technol Ther , vol.11 , pp. 145-150
    • McGarraugh, G.1    Bergenstal, R.2
  • 8
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    • STAR 3 Study Group
    • Bergenstal RM, Tamborlane WV, Ahmann A, et al.; STAR 3 Study Group. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010;363:311-320
    • (2010) N Engl J Med , vol.363 , pp. 311-320
    • Bergenstal, R.M.1    Tamborlane, W.V.2    Ahmann, A.3
  • 9
    • 79960098673 scopus 로고    scopus 로고
    • Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; A randomized controlled trial
    • Hermanides J, Nørgaard K, Bruttomesso D, et al. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial. Diabet Med 2011;28:1158-1167
    • (2011) Diabet Med , vol.28 , pp. 1158-1167
    • Hermanides, J.1    Nørgaard, K.2    Bruttomesso, D.3
  • 10
    • 84857865549 scopus 로고    scopus 로고
    • Reduction in duration of hypoglycemia by automatic suspension of insulin delivery: The in-clinic ASPIRE study
    • Garg S, Brazg RL, Bailey TS, et al. Reduction in duration of hypoglycemia by automatic suspension of insulin delivery: the in-clinic ASPIRE study. Diabetes Technol Ther 2012;14:205-209
    • (2012) Diabetes Technol Ther , vol.14 , pp. 205-209
    • Garg, S.1    Brazg, R.L.2    Bailey, T.S.3
  • 11
    • 80755148728 scopus 로고    scopus 로고
    • Artificial pancreas: Past, present, future
    • Cobelli C, Renard E, Kovatchev B. Artificial pancreas: past, present, future. Diabetes 2011;60:2672-2682
    • (2011) Diabetes , vol.60 , pp. 2672-2682
    • Cobelli, C.1    Renard, E.2    Kovatchev, B.3
  • 12
    • 77957127872 scopus 로고    scopus 로고
    • Smart continuous glucose monitoring sensors: On-line signal processing issues
    • Sparacino G, Facchinetti A, Cobelli C. "Smart" continuous glucose monitoring sensors: on-line signal processing issues. Sensors (Basel) 2010;10:6751-6772
    • (2010) Sensors (Basel) , vol.10 , pp. 6751-6772
    • Sparacino, G.1    Facchinetti, A.2    Cobelli, C.3
  • 13
    • 77955504672 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Real-time algorithms for calibration, filtering, and alarms
    • Bequette BW. Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms. J Diabetes Sci Tech 2010;4:404-418
    • (2010) J Diabetes Sci Tech , vol.4 , pp. 404-418
    • Bequette, B.W.1
  • 14
    • 33744908804 scopus 로고    scopus 로고
    • Integral-based filtering of continuous glucose sensormeasurements for glycaemic control in critical care
    • Chase JG, Hann CE, Jackson M, et al. Integral-based filtering of continuous glucose sensormeasurements for glycaemic control in critical care. Comput Methods Programs Biomed 2006;82:238-247
    • (2006) Comput Methods Programs Biomed , vol.82 , pp. 238-247
    • Chase, J.G.1    Hann, C.E.2    Jackson, M.3
  • 17
    • 80052042615 scopus 로고    scopus 로고
    • Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring
    • Facchinetti A, Sparacino G, Cobelli C. Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring. IEEE Trans Biomed Eng 2011;58:2664-2671
    • (2011) IEEE Trans Biomed Eng , vol.58 , pp. 2664-2671
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 19
    • 78650269743 scopus 로고    scopus 로고
    • Estimating plasma glucose from interstitial glucose: The issue of calibration algorithms in commercial continuous glucose monitoring devices
    • Rossetti P, Bondia J, Vehi J, Fanelli CG. Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices. Sensors (Basel) 2010;10:10936-10952
    • (2010) Sensors (Basel) , vol.10 , pp. 10936-10952
    • Rossetti, P.1    Bondia, J.2    Vehi, J.3    Fanelli, C.G.4
  • 20
    • 59649089217 scopus 로고    scopus 로고
    • Modeling of calibration effectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp
    • King C, Anderson SM, Breton M, Clarke WL, Kovatchev BP. Modeling of calibration effectiveness and blood-to-interstitial glucose dynamics as potential confounders of the accuracy of continuous glucose sensors during hyperinsulinemic clamp. J Diabetes Sci Tech 2007;1:317-322
    • (2007) J Diabetes Sci Tech , vol.1 , pp. 317-322
    • King, C.1    Anderson, S.M.2    Breton, M.3    Clarke, W.L.4    Kovatchev, B.P.5
  • 21
    • 77649133392 scopus 로고    scopus 로고
    • Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: Role of sensor calibration
    • Facchinetti A, Sparacino G, Cobelli C. Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration. J Diabetes Sci Tech 2007; 1:617-623
    • (2007) J Diabetes Sci Tech , vol.1 , pp. 617-623
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 22
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman filter for continuous glucose monitoring
    • Knobbe EJ, Buckingham B. The extended Kalman filter for continuous glucose monitoring. Diabetes Technol Ther 2005; 7:15-27
    • (2005) Diabetes Technol Ther , vol.7 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 23
    • 77951129243 scopus 로고    scopus 로고
    • Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering
    • Facchinetti A, Sparacino G, Cobelli C. Enhanced accuracy of continuous glucose monitoring by online extended kalman filtering. Diabetes Technol Ther 2010;12: 353-363
    • (2010) Diabetes Technol Ther , vol.12 , pp. 353-363
    • Facchinetti, A.1    Sparacino, G.2    Cobelli, C.3
  • 24
    • 84855461899 scopus 로고    scopus 로고
    • A multiple local models approach to accuracy improvement in continuous glucose monitoring
    • Barceló-Rico F, Bondia J, Díez JL, Rossetti P. A multiple local models approach to accuracy improvement in continuous glucose monitoring. Diabetes Technol Ther 2012;14:74-82
    • (2012) Diabetes Technol Ther , vol.14 , pp. 74-82
    • Barceló-Rico, F.1    Bondia, J.2    Díez, J.L.3    Rossetti, P.4
  • 25
    • 84861405223 scopus 로고    scopus 로고
    • Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolution-based approach
    • Guerra S, Facchinetti A, Sparacino G, Nicolao GD, Cobelli C. Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach. IEEE Trans Biomed Eng 2012; 59:1658-1669
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 1658-1669
    • Guerra, S.1    Facchinetti, A.2    Sparacino, G.3    Nicolao, G.D.4    Cobelli, C.5
  • 26
    • 34247372642 scopus 로고    scopus 로고
    • Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series
    • Sparacino G, Zanderigo F, Corazza S, Maran A, Facchinetti A, Cobelli C. Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensor time-series. IEEE Trans Biomed Eng 2007;54:931-937
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 931-937
    • Sparacino, G.1    Zanderigo, F.2    Corazza, S.3    Maran, A.4    Facchinetti, A.5    Cobelli, C.6
  • 27
    • 63849301691 scopus 로고    scopus 로고
    • Predicting subcutaneous glucose concentration in humans: Datadriven glucose modeling
    • Gani A, Gribok AV, Rajaraman S, Ward WK, Reifman J. Predicting subcutaneous glucose concentration in humans: datadriven glucose modeling. IEEE Trans Biomed Eng 2009;56:246-254
    • (2009) IEEE Trans Biomed Eng , vol.56 , pp. 246-254
    • Gani, A.1    Gribok, A.V.2    Rajaraman, S.3    Ward, W.K.4    Reifman, J.5
  • 28
    • 64349107874 scopus 로고    scopus 로고
    • Estimation of future glucose concentrations with subject-specific recursive linear models
    • Eren-Oruklu M, Cinar A, Quinn L, Smith D. Estimation of future glucose concentrations with subject-specific recursive linear models. Diabetes Technol Ther 2009;11:243-253
    • (2009) Diabetes Technol Ther , vol.11 , pp. 243-253
    • Eren-Oruklu, M.1    Cinar, A.2    Quinn, L.3    Smith, D.4
  • 29
    • 75749130634 scopus 로고    scopus 로고
    • Artificial neural network algorithm for online glucose prediction from continuous glucose monitoring
    • Pérez-Gandía C, Facchinetti A, Sparacino G, et al. Artificial neural network algorithm for online glucose prediction from continuous glucose monitoring. Diabetes Technol Ther 2010;12:81-88
    • (2010) Diabetes Technol Ther , vol.12 , pp. 81-88
    • Pérez-Gandía, C.1    Facchinetti, A.2    Sparacino, G.3
  • 30
    • 77955652578 scopus 로고    scopus 로고
    • Real-Time hypoglycemia prediction suite using continuous glucose monitoring: A safety net for the artificial pancreas
    • Dassau E, Cameron F, Lee H, et al. Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas. Diabetes Care 2010;33:1249-1254
    • (2010) Diabetes Care , vol.33 , pp. 1249-1254
    • Dassau, E.1    Cameron, F.2    Lee, H.3
  • 31
    • 79551610188 scopus 로고    scopus 로고
    • Neural network-based real-time prediction of glucose in patients with insulin-dependent diabetes
    • Pappada SM, Cameron BD, Rosman PM, et al. Neural network-based real-time prediction of glucose in patients with insulin-dependent diabetes. Diabetes Technol Ther 2011;13:135-141
    • (2011) Diabetes Technol Ther , vol.13 , pp. 135-141
    • Pappada, S.M.1    Cameron, B.D.2    Rosman, P.M.3
  • 32
    • 84861394725 scopus 로고    scopus 로고
    • Neural network incorporating meal information improves accuracy of short-time prediction of glucose concentration
    • Zecchin C, Facchinetti A, Sparacino G, De Nicolao G, Cobelli C. Neural network incorporating meal information improves accuracy of short-time prediction of glucose concentration. IEEE Trans Biomed Eng 2012;59:1550-1560
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 1550-1560
    • Zecchin, C.1    Facchinetti, A.2    Sparacino, G.3    De Nicolao, G.4    Cobelli, C.5
  • 33
    • 84875418484 scopus 로고    scopus 로고
    • Accessed 6 April 2012
    • Artificial Pancreas (AP) at home. Available from http://www.apathome.eu. Accessed 6 April 2012.
    • Artificial Pancreas (AP) at Home
  • 34
    • 79551580499 scopus 로고    scopus 로고
    • A new index to optimally design and compare continuous glucose monitoring glucose prediction algorithms
    • Facchinetti A, Sparacino G, Trifoglio E, Cobelli C. A new index to optimally design and compare continuous glucose monitoring glucose prediction algorithms. Diabetes Technol Ther 2011;13: 111-119
    • (2011) Diabetes Technol Ther , vol.13 , pp. 111-119
    • Facchinetti, A.1    Sparacino, G.2    Trifoglio, E.3    Cobelli, C.4
  • 35
    • 78650760751 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W. Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care 2008;31: 1160-1164
    • (2008) Diabetes Care , vol.31 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 36
    • 70349240850 scopus 로고    scopus 로고
    • Statistical tools to analyze continuous glucose monitor data
    • Clarke W, Kovatchev B. Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther 2009;11(Suppl. 1):S45-S54
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Clarke, W.1    Kovatchev, B.2
  • 38
    • 84863298190 scopus 로고    scopus 로고
    • Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms
    • Keenan DB, Mastrototaro JJ, Zisser H, et al. Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms. Diabetes Technol Ther 2012; 14:225-231
    • (2012) Diabetes Technol Ther , vol.14 , pp. 225-231
    • Keenan, D.B.1    Mastrototaro, J.J.2    Zisser, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.