메뉴 건너뛰기




Volumn 1421, Issue , 2015, Pages 68-81

Aerosol-based detectors for liquid chromatography

Author keywords

Aerosol based detectors; Liquid chromatography detectors; Universal detectors

Indexed keywords

AEROSOLS; CHROMATOGRAPHY; LIGHT SCATTERING; LIQUIDS;

EID: 84960498585     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2015.07.045     Document Type: Review
Times cited : (79)

References (126)
  • 1
    • 0001062869 scopus 로고
    • High-performance liquid chromatography past developments, present status, and future trends
    • Brown P.R. High-performance liquid chromatography past developments, present status, and future trends. Anal. Chem. 1990, 62:995A-1008A.
    • (1990) Anal. Chem. , vol.62 , pp. 995A-1008A
    • Brown, P.R.1
  • 2
    • 0000770371 scopus 로고
    • Evaporative analyzer as a mass detector for liquid chromatography
    • Charlesworth J.M. Evaporative analyzer as a mass detector for liquid chromatography. Anal. Chem. 1978, 50:1414-1420.
    • (1978) Anal. Chem. , vol.50 , pp. 1414-1420
    • Charlesworth, J.M.1
  • 3
    • 0001620247 scopus 로고
    • Condensation nucleation light scattering: a new approach to development of high-sensitivity, universal detectors for separations
    • Allen L.B., Koropchak J.A. Condensation nucleation light scattering: a new approach to development of high-sensitivity, universal detectors for separations. Anal. Chem. 1993, 65:841-844.
    • (1993) Anal. Chem. , vol.65 , pp. 841-844
    • Allen, L.B.1    Koropchak, J.A.2
  • 4
    • 0036629244 scopus 로고    scopus 로고
    • Development and testing of a detection method for liquid chromatography based on aerosol charging
    • Dixon R.W., Peterson D.S. Development and testing of a detection method for liquid chromatography based on aerosol charging. Anal. Chem. 2002, 74:2930-2937.
    • (2002) Anal. Chem. , vol.74 , pp. 2930-2937
    • Dixon, R.W.1    Peterson, D.S.2
  • 5
    • 0034496675 scopus 로고    scopus 로고
    • Fundamental aspects of aerosol-based light-scattering detectors for separations
    • Marcel Dekker, New York, (chapter 5)
    • Koropchak J.A., Magnusson L.-E., Heybroek M., Sadain S., Yang X., Anisimov M.P. Fundamental aspects of aerosol-based light-scattering detectors for separations. Advances in Chromatography 2000, vol. 40:275-314. Marcel Dekker, New York, (chapter 5).
    • (2000) Advances in Chromatography , vol.40 , pp. 275-314
    • Koropchak, J.A.1    Magnusson, L.-E.2    Heybroek, M.3    Sadain, S.4    Yang, X.5    Anisimov, M.P.6
  • 6
    • 4243193994 scopus 로고    scopus 로고
    • The evaporative light scattering detector. A universal instrument for non-volatile solutes in LC and SFC
    • Dreux M., Lafosse M., Morin-Allory L. The evaporative light scattering detector. A universal instrument for non-volatile solutes in LC and SFC. LC-GC Int. 1996, 9:148-156.
    • (1996) LC-GC Int. , vol.9 , pp. 148-156
    • Dreux, M.1    Lafosse, M.2    Morin-Allory, L.3
  • 9
    • 0035300243 scopus 로고    scopus 로고
    • Evaporative light-scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: sensitivity, linearity of response and comparisons with UV absorbance detection
    • Cobb Z., Barret D., Shaw P., Meehan E., Watkins J., O'Donohue S., Wrench N. Evaporative light-scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: sensitivity, linearity of response and comparisons with UV absorbance detection. J. Microcol. Sep. 2001, 13:169-175.
    • (2001) J. Microcol. Sep. , vol.13 , pp. 169-175
    • Cobb, Z.1    Barret, D.2    Shaw, P.3    Meehan, E.4    Watkins, J.5    O'Donohue, S.6    Wrench, N.7
  • 11
    • 33645003476 scopus 로고    scopus 로고
    • Application of a xenon arc lamp as a light source for evaporative light scattering detection
    • Gaudin K., Baillet A., Chaminade P. Application of a xenon arc lamp as a light source for evaporative light scattering detection. Anal. Bioanal. Chem. 2006, 384:1302-1307.
    • (2006) Anal. Bioanal. Chem. , vol.384 , pp. 1302-1307
    • Gaudin, K.1    Baillet, A.2    Chaminade, P.3
  • 12
    • 7744222854 scopus 로고    scopus 로고
    • Enhancement of evaporative light scattering detection in high-performance liquid chromatographic determination of neomycin based on highly volatile mobile phase, high-molecular-mass ion-pairing reagents and controlled peak shape
    • Mefoulas N., Koupparis M. Enhancement of evaporative light scattering detection in high-performance liquid chromatographic determination of neomycin based on highly volatile mobile phase, high-molecular-mass ion-pairing reagents and controlled peak shape. J. Chromatogr. A 2004, 1057:125-131.
    • (2004) J. Chromatogr. A , vol.1057 , pp. 125-131
    • Mefoulas, N.1    Koupparis, M.2
  • 13
    • 0035180035 scopus 로고    scopus 로고
    • Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species
    • Deschamps F.S., Gaudin K., Lesellier E., Tchapla A., Ferrier D., Baillet A., Chaminade P. Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species. Chromatographia 2001, 54(9/10):607-611.
    • (2001) Chromatographia , vol.54 , Issue.9-10 , pp. 607-611
    • Deschamps, F.S.1    Gaudin, K.2    Lesellier, E.3    Tchapla, A.4    Ferrier, D.5    Baillet, A.6    Chaminade, P.7
  • 14
    • 2342618818 scopus 로고    scopus 로고
    • Optimisation of the separation of four major neutral glycosphingolipids: application to a rapid and simple detection of urinary globotriaosylceramide in Fabry disease
    • Roy S., Gaudin K., Germain D.P., Baillet A., Prognon P., Chaminade P. Optimisation of the separation of four major neutral glycosphingolipids: application to a rapid and simple detection of urinary globotriaosylceramide in Fabry disease. J. Chromatogr. B 2004, 805:331-337.
    • (2004) J. Chromatogr. B , vol.805 , pp. 331-337
    • Roy, S.1    Gaudin, K.2    Germain, D.P.3    Baillet, A.4    Prognon, P.5    Chaminade, P.6
  • 15
    • 77949262333 scopus 로고    scopus 로고
    • Use of evaporative light scattering detection for the quality control of drug substances: influence of different liquid chromatographic and evaporative light scattering detector parameters on the appearance of spike peaks
    • Almeling S., Holzgrabe U. Use of evaporative light scattering detection for the quality control of drug substances: influence of different liquid chromatographic and evaporative light scattering detector parameters on the appearance of spike peaks. J. Chromatogr. A 2010, 1217:2163-2170.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 2163-2170
    • Almeling, S.1    Holzgrabe, U.2
  • 16
    • 0021875476 scopus 로고
    • Evaluation of the mass detector for quantitative detection of triglycerides and fatty acid methyl esters
    • Robinson J.L., Tsimido M., Macrae R.J. Evaluation of the mass detector for quantitative detection of triglycerides and fatty acid methyl esters. J. Chromatogr. 1985, 324:35-51.
    • (1985) J. Chromatogr. , vol.324 , pp. 35-51
    • Robinson, J.L.1    Tsimido, M.2    Macrae, R.J.3
  • 17
    • 0021647708 scopus 로고
    • Analysis of steroids in bulk pharmaceuticals by liquid chromatography with light-scattering detection
    • Asmus P.A., Landis J.B. Analysis of steroids in bulk pharmaceuticals by liquid chromatography with light-scattering detection. J. Chromatogr. 1984, 316:461-472.
    • (1984) J. Chromatogr. , vol.316 , pp. 461-472
    • Asmus, P.A.1    Landis, J.B.2
  • 19
    • 32644489832 scopus 로고    scopus 로고
    • Development and validation of a novel LC non-derivatization method for the determination of amikacin in pharmaceuticals based on evaporative light scattering detection
    • Galanakis E.G., Megoulas N.C., Solich P., Koupparis M.A. Development and validation of a novel LC non-derivatization method for the determination of amikacin in pharmaceuticals based on evaporative light scattering detection. J. Pharm. Biomed. Anal. 2006, 40:1114-1120.
    • (2006) J. Pharm. Biomed. Anal. , vol.40 , pp. 1114-1120
    • Galanakis, E.G.1    Megoulas, N.C.2    Solich, P.3    Koupparis, M.A.4
  • 20
    • 13444309434 scopus 로고    scopus 로고
    • Adsorption of polypropylene from dilute solutions on a zeolite column packing
    • Macko T., Pasch H., Denayer J.F. Adsorption of polypropylene from dilute solutions on a zeolite column packing. J. Sep. Sci. 2005, 28:59-64.
    • (2005) J. Sep. Sci. , vol.28 , pp. 59-64
    • Macko, T.1    Pasch, H.2    Denayer, J.F.3
  • 21
    • 34547661735 scopus 로고    scopus 로고
    • Separation of ethylene-vinyl acetate copolymers by high-temperature gradient liquid chromatography
    • Albrecht A., Brull R., Macko T., Pasch H. Separation of ethylene-vinyl acetate copolymers by high-temperature gradient liquid chromatography. Macromolecules 2007, 40:5545-5551.
    • (2007) Macromolecules , vol.40 , pp. 5545-5551
    • Albrecht, A.1    Brull, R.2    Macko, T.3    Pasch, H.4
  • 22
    • 64749106156 scopus 로고    scopus 로고
    • Evaporative light scattering detector: toward a general molecular weight cutoff characterization of nanofiltration membranes
    • Li X., Monsuur F., Denoulet B., Dobrak A., Vandezande P., Vankelecom I.F.J. Evaporative light scattering detector: toward a general molecular weight cutoff characterization of nanofiltration membranes. Anal. Chem. 2009, 81:1801-1809.
    • (2009) Anal. Chem. , vol.81 , pp. 1801-1809
    • Li, X.1    Monsuur, F.2    Denoulet, B.3    Dobrak, A.4    Vandezande, P.5    Vankelecom, I.F.J.6
  • 23
    • 70649105565 scopus 로고    scopus 로고
    • Comparison of the sensitivity of evaporative universal detectors and LC/MS in the HILIC and the reversed-phase HPLC modes
    • Mitchell C.R., Bao Y., Benz N.J., Zhang S. Comparison of the sensitivity of evaporative universal detectors and LC/MS in the HILIC and the reversed-phase HPLC modes. J. Chromatogr. B 2009, 877:4133-4139.
    • (2009) J. Chromatogr. B , vol.877 , pp. 4133-4139
    • Mitchell, C.R.1    Bao, Y.2    Benz, N.J.3    Zhang, S.4
  • 24
    • 8844242479 scopus 로고    scopus 로고
    • An investigation into detector limitations using evaporative light-scattering detectors for pharmaceutical applications
    • Webster G.K., Jensen J.S., Diaz A.R. An investigation into detector limitations using evaporative light-scattering detectors for pharmaceutical applications. J. Chromatogr. Sci. 2004, 42(9):484-490.
    • (2004) J. Chromatogr. Sci. , vol.42 , Issue.9 , pp. 484-490
    • Webster, G.K.1    Jensen, J.S.2    Diaz, A.R.3
  • 25
    • 22244450984 scopus 로고    scopus 로고
    • Development of Ginkgo biloba fingerprint chromatogram with UV and evaporative light scattering detection and optimization of the evaporative light scattering detector operating conditions
    • Van Nederkassel A.M., Vijverman V., Massart D.L., Vaner Heyden Y. Development of Ginkgo biloba fingerprint chromatogram with UV and evaporative light scattering detection and optimization of the evaporative light scattering detector operating conditions. J. Chromatogr. A 2005, 1085:230-239.
    • (2005) J. Chromatogr. A , vol.1085 , pp. 230-239
    • Van Nederkassel, A.M.1    Vijverman, V.2    Massart, D.L.3    Vaner Heyden, Y.4
  • 26
    • 42649128019 scopus 로고    scopus 로고
    • Micro liquid chromatography coupled with evaporative light scattering detector at ambient and high temperature: optimization of the nebulization cell geometry
    • Guillarme D., Rudaz S., Schelling C., Dreux M., Veuthey J.L. Micro liquid chromatography coupled with evaporative light scattering detector at ambient and high temperature: optimization of the nebulization cell geometry. J. Chromatogr. A 2008, 1192:103-112.
    • (2008) J. Chromatogr. A , vol.1192 , pp. 103-112
    • Guillarme, D.1    Rudaz, S.2    Schelling, C.3    Dreux, M.4    Veuthey, J.L.5
  • 27
    • 79251596030 scopus 로고    scopus 로고
    • Effect of chromatographic parameter and detector settings on the response of HILIC-evaporative light-scattering detection system using experimental design approach and multicriteria optimization methodology
    • Karatapanis A.E., Fiamegos Y.C., Sakkas V.A., Stalikas C.D. Effect of chromatographic parameter and detector settings on the response of HILIC-evaporative light-scattering detection system using experimental design approach and multicriteria optimization methodology. Talanta 2011, 83:1126-1133.
    • (2011) Talanta , vol.83 , pp. 1126-1133
    • Karatapanis, A.E.1    Fiamegos, Y.C.2    Sakkas, V.A.3    Stalikas, C.D.4
  • 28
    • 34447650586 scopus 로고    scopus 로고
    • Improving the universal response of evaporative light scattering detection by mobile phase compensation
    • Villiers A., Gorecki T., Lynen F., Szucs R., Sandra P. Improving the universal response of evaporative light scattering detection by mobile phase compensation. J. Chromatogr. A 2007, 1161:183-191.
    • (2007) J. Chromatogr. A , vol.1161 , pp. 183-191
    • Villiers, A.1    Gorecki, T.2    Lynen, F.3    Szucs, R.4    Sandra, P.5
  • 29
    • 55449117280 scopus 로고    scopus 로고
    • Review and optimization of linearity and precision in quantitative HPLC-ELSD with chemometrics
    • Walfish S., Aruda W.O., Krull I.S. Review and optimization of linearity and precision in quantitative HPLC-ELSD with chemometrics. LC-GC North Am. 2008, (October (1)):1032-1042.
    • (2008) LC-GC North Am. , Issue.OCTOBER 1 , pp. 1032-1042
    • Walfish, S.1    Aruda, W.O.2    Krull, I.S.3
  • 30
    • 30144444641 scopus 로고    scopus 로고
    • Twenty years of evaporative light scattering detection
    • Mefoulas N.C., Kourpparis M.A. Twenty years of evaporative light scattering detection. Crit. Rev. Anal. Chem. 2005, 35:301-316.
    • (2005) Crit. Rev. Anal. Chem. , vol.35 , pp. 301-316
    • Mefoulas, N.C.1    Kourpparis, M.A.2
  • 31
    • 0031239583 scopus 로고    scopus 로고
    • The evaporative light scattering detector: some applications in pharmaceutical analysis
    • Kohler M., Haerdi W., Christen P., Veuthey J.-L. The evaporative light scattering detector: some applications in pharmaceutical analysis. Trends Anal. Chem. 1997, 16(8):475-484.
    • (1997) Trends Anal. Chem. , vol.16 , Issue.8 , pp. 475-484
    • Kohler, M.1    Haerdi, W.2    Christen, P.3    Veuthey, J.-L.4
  • 33
    • 84893862228 scopus 로고    scopus 로고
    • Carbohydrate analysis: from sample preparation to HPLC on different stationary phases coupled with evaporative light-scattering detection
    • Dvorackova E., Snoblova M., Hrdlicka P. Carbohydrate analysis: from sample preparation to HPLC on different stationary phases coupled with evaporative light-scattering detection. J. Sep. Sci. 2014, 37:323-337.
    • (2014) J. Sep. Sci. , vol.37 , pp. 323-337
    • Dvorackova, E.1    Snoblova, M.2    Hrdlicka, P.3
  • 34
    • 84892034883 scopus 로고    scopus 로고
    • Use of evaporative light scattering detection (ELSD) for the quality control of drug substances
    • Nova Publishers Inc., New York, T.J. Quintin (Ed.)
    • Holzgrabe U., Brinz D., Weber C., Almeling S. Use of evaporative light scattering detection (ELSD) for the quality control of drug substances. Chromatography: Types, Techniques and Methods 2010, 483-496. Nova Publishers Inc., New York. T.J. Quintin (Ed.).
    • (2010) Chromatography: Types, Techniques and Methods , pp. 483-496
    • Holzgrabe, U.1    Brinz, D.2    Weber, C.3    Almeling, S.4
  • 35
    • 85031876190 scopus 로고    scopus 로고
    • Evaporative light scattering detection
    • J. Cazes (Ed.)
    • Alvarez J.G. Evaporative light scattering detection. Encyclopedia of Chromatography 2010, 816-817. 3rd ed. J. Cazes (Ed.).
    • (2010) Encyclopedia of Chromatography , pp. 816-817
    • Alvarez, J.G.1
  • 37
    • 4444287713 scopus 로고    scopus 로고
    • Development and validation of a novel LC/ELSD method for the quantitation of gentamicin sulfate components in pharmaceuticals
    • Megoulas N.C., Koupparis M.A. Development and validation of a novel LC/ELSD method for the quantitation of gentamicin sulfate components in pharmaceuticals. J. Pharm. Biomed. Anal. 2004, 36:73-79.
    • (2004) J. Pharm. Biomed. Anal. , vol.36 , pp. 73-79
    • Megoulas, N.C.1    Koupparis, M.A.2
  • 38
    • 0842330583 scopus 로고    scopus 로고
    • Simultaneous separation and quantitation of four antiepileptic drugs - a study with potential for use in patient drug level monitoring
    • Manoj Babu M.K. Simultaneous separation and quantitation of four antiepileptic drugs - a study with potential for use in patient drug level monitoring. J. Pharm. Biomed. Anal. 2004, 34(2):315-324.
    • (2004) J. Pharm. Biomed. Anal. , vol.34 , Issue.2 , pp. 315-324
    • Manoj Babu, M.K.1
  • 39
    • 57049117318 scopus 로고    scopus 로고
    • Quantitation of polysorbate 20 in protein solutions using mixed-mode chromatography and evaporative light scattering detection
    • Hewitt D., Zhang R., Kao Y.-H. Quantitation of polysorbate 20 in protein solutions using mixed-mode chromatography and evaporative light scattering detection. J. Chromatogr. A 2008, 1215:156-160.
    • (2008) J. Chromatogr. A , vol.1215 , pp. 156-160
    • Hewitt, D.1    Zhang, R.2    Kao, Y.-H.3
  • 40
    • 0041327981 scopus 로고    scopus 로고
    • Determination of polysorbate 80 in parenteral formulations by high-performance liquid chromatography and evaporative light scattering detection
    • Nair L.M., Stephens N.V., Vincent S., Raghavan N., Sand P.J. Determination of polysorbate 80 in parenteral formulations by high-performance liquid chromatography and evaporative light scattering detection. J. Chromatogr. A 2003, 1012:81-86.
    • (2003) J. Chromatogr. A , vol.1012 , pp. 81-86
    • Nair, L.M.1    Stephens, N.V.2    Vincent, S.3    Raghavan, N.4    Sand, P.J.5
  • 41
    • 84886488181 scopus 로고    scopus 로고
    • Application of HPLC with ELSD detection for the assessment of azelaic acid impurities in liposomal formulation
    • 564962
    • Han S., Karlowicz-Bodalska K., Szura D., Ozimek L., Musial W. Application of HPLC with ELSD detection for the assessment of azelaic acid impurities in liposomal formulation. Sci. World J. 2013, 564962:1-8.
    • (2013) Sci. World J. , pp. 1-8
    • Han, S.1    Karlowicz-Bodalska, K.2    Szura, D.3    Ozimek, L.4    Musial, W.5
  • 42
    • 24744440727 scopus 로고    scopus 로고
    • Determination of ibandronate and its degradation products by ion-pair RP LC with evaporative light-scattering detection
    • Jian Y., Xie A. Determination of ibandronate and its degradation products by ion-pair RP LC with evaporative light-scattering detection. Chromatographia 2005, 62(5/6):257-261.
    • (2005) Chromatographia , vol.62 , Issue.5-6 , pp. 257-261
    • Jian, Y.1    Xie, A.2
  • 43
    • 0037325145 scopus 로고    scopus 로고
    • RP-HPLC determination of midecamycin and related impurities
    • Liu Y., Hu C. RP-HPLC determination of midecamycin and related impurities. Chromatographia 2003, 57(3/4):143-146.
    • (2003) Chromatographia , vol.57 , Issue.3-4 , pp. 143-146
    • Liu, Y.1    Hu, C.2
  • 44
    • 33645082210 scopus 로고    scopus 로고
    • Analysis of spectinomycin by HPLC with evaporative light-scattering detection
    • Wang M.-J., Hu C. Analysis of spectinomycin by HPLC with evaporative light-scattering detection. Chromatographia 2006, 63(5/6):255-260.
    • (2006) Chromatographia , vol.63 , Issue.5-6 , pp. 255-260
    • Wang, M.-J.1    Hu, C.2
  • 45
    • 79960764344 scopus 로고    scopus 로고
    • HPLC-ELSD analysis of spectinomycin dihydrochloride and its impurities
    • Zhou J., Zhang L., Wang Y., Yan C. HPLC-ELSD analysis of spectinomycin dihydrochloride and its impurities. J. Sep. Sci. 2011, 34:1811-1819.
    • (2011) J. Sep. Sci. , vol.34 , pp. 1811-1819
    • Zhou, J.1    Zhang, L.2    Wang, Y.3    Yan, C.4
  • 46
    • 0028794491 scopus 로고
    • Validation of an HPLC method for the determination of sodium in LY239111 sodium, a novel LTB4 receptor antagonist, using evaporative light scattering detection
    • Peterson J.A., Risley D.S. Validation of an HPLC method for the determination of sodium in LY239111 sodium, a novel LTB4 receptor antagonist, using evaporative light scattering detection. J. Liq. Chromatogr. 1995, 18:331-338.
    • (1995) J. Liq. Chromatogr. , vol.18 , pp. 331-338
    • Peterson, J.A.1    Risley, D.S.2
  • 47
    • 33749393555 scopus 로고    scopus 로고
    • An alternative method for the determination of chloride in pharmaceutical drug substances using HPLC and evaporative light-scattering detection
    • Risley D.S., Peterson J.A., Griffiths K., McCarthy S. An alternative method for the determination of chloride in pharmaceutical drug substances using HPLC and evaporative light-scattering detection. LC-GC N. Am. 1996, 14:1040-1047.
    • (1996) LC-GC N. Am. , vol.14 , pp. 1040-1047
    • Risley, D.S.1    Peterson, J.A.2    Griffiths, K.3    McCarthy, S.4
  • 48
    • 33845235442 scopus 로고    scopus 로고
    • Simultaneous determination of positive and negative counterions using a hydrophilic interaction chromatography method
    • Risley D.S., Pack B.W. Simultaneous determination of positive and negative counterions using a hydrophilic interaction chromatography method. LC-GC N. Am. 2006, 24:776-785.
    • (2006) LC-GC N. Am. , vol.24 , pp. 776-785
    • Risley, D.S.1    Pack, B.W.2
  • 49
    • 33746407592 scopus 로고    scopus 로고
    • Use of evaporative light scattering detector in the detection and quantification of enantiomeric mixtures by HPLC
    • Zhang T., Nguyen D., Franco P. Use of evaporative light scattering detector in the detection and quantification of enantiomeric mixtures by HPLC. J. Sep. Sci. 2006, 29:1517-1524.
    • (2006) J. Sep. Sci. , vol.29 , pp. 1517-1524
    • Zhang, T.1    Nguyen, D.2    Franco, P.3
  • 50
    • 33746489548 scopus 로고    scopus 로고
    • Excipient quantitation and drug distribution during formulation optimization
    • Forget R., Spagnoli S. Excipient quantitation and drug distribution during formulation optimization. J. Pharm. Biomed. Anal. 2006, 41:1051-1055.
    • (2006) J. Pharm. Biomed. Anal. , vol.41 , pp. 1051-1055
    • Forget, R.1    Spagnoli, S.2
  • 51
    • 20444477929 scopus 로고    scopus 로고
    • Study of the analysis of alkoxyglycerols and other non-polar lipids by liquid chromatography coupled with evaporative light scattering detector
    • Torres C.F., Vazquez L., Senorans J., Reglero G. Study of the analysis of alkoxyglycerols and other non-polar lipids by liquid chromatography coupled with evaporative light scattering detector. J. Chromatogr. A 2005, 1078:28-34.
    • (2005) J. Chromatogr. A , vol.1078 , pp. 28-34
    • Torres, C.F.1    Vazquez, L.2    Senorans, J.3    Reglero, G.4
  • 52
    • 0141528508 scopus 로고    scopus 로고
    • Migration of lubricants from food packagings: screening for lipid classes and quantitative estimation using normal-phase liquid chromatographic separation with evaporative light scattering detection
    • Schaefer A., Kuchler T., Simat T.J., Steinhart H. Migration of lubricants from food packagings: screening for lipid classes and quantitative estimation using normal-phase liquid chromatographic separation with evaporative light scattering detection. J. Chromatogr. A 2003, 1017:107-116.
    • (2003) J. Chromatogr. A , vol.1017 , pp. 107-116
    • Schaefer, A.1    Kuchler, T.2    Simat, T.J.3    Steinhart, H.4
  • 53
    • 67049116050 scopus 로고    scopus 로고
    • Improved separation and quantification of neutral and polar lipid classes by HPLC-ELSD using a monolithic silica phase: application to exceptional marine lipids
    • Graeve M., Janssen D. Improved separation and quantification of neutral and polar lipid classes by HPLC-ELSD using a monolithic silica phase: application to exceptional marine lipids. J. Chromatogr. B 2009, 877:1815-1819.
    • (2009) J. Chromatogr. B , vol.877 , pp. 1815-1819
    • Graeve, M.1    Janssen, D.2
  • 54
    • 77951207365 scopus 로고    scopus 로고
    • Major lipid classes separation of buttermilk, and cows, goats and ewes milk by high performance liquid chromatography with an evaporative light scattering detector focused on the phospholipid fraction
    • Rodriguez-Alcala L.M., Fontecha J. Major lipid classes separation of buttermilk, and cows, goats and ewes milk by high performance liquid chromatography with an evaporative light scattering detector focused on the phospholipid fraction. J. Chromatogr. A 2010, 1217:3063-3066.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3063-3066
    • Rodriguez-Alcala, L.M.1    Fontecha, J.2
  • 55
    • 33846813412 scopus 로고    scopus 로고
    • Phospho- and sphingolipid content of selected dairy products as determined by HPLC coupled to an evaporative light scattering detector (HPLC-ELSD)
    • Rombaut R., Dewettinck K., Van Camp J. Phospho- and sphingolipid content of selected dairy products as determined by HPLC coupled to an evaporative light scattering detector (HPLC-ELSD). J. Food Comp. Anal. 2007, 20:308-312.
    • (2007) J. Food Comp. Anal. , vol.20 , pp. 308-312
    • Rombaut, R.1    Dewettinck, K.2    Van Camp, J.3
  • 56
    • 13644277542 scopus 로고    scopus 로고
    • Separation and quantification of beer carbohydrates by high-performance liquid chromatography with evaporative light scattering detection
    • Nogueira L.C., Silva F., Ferreira I., Trugo L.C. Separation and quantification of beer carbohydrates by high-performance liquid chromatography with evaporative light scattering detection. J. Chromatogr. A 2005, 1065:207-210.
    • (2005) J. Chromatogr. A , vol.1065 , pp. 207-210
    • Nogueira, L.C.1    Silva, F.2    Ferreira, I.3    Trugo, L.C.4
  • 57
    • 0034704436 scopus 로고    scopus 로고
    • Analysis of carbohydrates in drinks by high-performance liquid chromatography with a dynamically modified amino column and evaporative light scattering detection
    • Wei Y., Ding M.-Y. Analysis of carbohydrates in drinks by high-performance liquid chromatography with a dynamically modified amino column and evaporative light scattering detection. J. Chromatogr. A 2000, 904:113-117.
    • (2000) J. Chromatogr. A , vol.904 , pp. 113-117
    • Wei, Y.1    Ding, M.-Y.2
  • 58
    • 84883637367 scopus 로고    scopus 로고
    • Evaluation of sugar content and composition in commonly consumed Korean vegetables, fruits, cereals, seed plants, and leave by HPLC-ELSD
    • Shanmugavelan P., Kim S.Y., Kim J.B., Kim H.W., Cho S.M., Kim S.N., Kim S.Y., Cho Y.S., Kim H.R. Evaluation of sugar content and composition in commonly consumed Korean vegetables, fruits, cereals, seed plants, and leave by HPLC-ELSD. Carbohydr. Res. 2013, 380:112-117.
    • (2013) Carbohydr. Res. , vol.380 , pp. 112-117
    • Shanmugavelan, P.1    Kim, S.Y.2    Kim, J.B.3    Kim, H.W.4    Cho, S.M.5    Kim, S.N.6    Kim, S.Y.7    Cho, Y.S.8    Kim, H.R.9
  • 59
    • 84884363079 scopus 로고    scopus 로고
    • Simultaneous separation and determination of fructose, sorbitol, glucose and sucrose in fruits by HPLC-ELSD
    • Ma C., Sun Z., Chen C., Zhang L., Zhu S. Simultaneous separation and determination of fructose, sorbitol, glucose and sucrose in fruits by HPLC-ELSD. Food Chem. 2014, 145:784-788.
    • (2014) Food Chem. , vol.145 , pp. 784-788
    • Ma, C.1    Sun, Z.2    Chen, C.3    Zhang, L.4    Zhu, S.5
  • 60
    • 25844477045 scopus 로고    scopus 로고
    • Separation of monosaccharides by hydrophilic interaction chromatography with evaporative light scattering detection
    • Karlsson G., Winge S., Sandberg H. Separation of monosaccharides by hydrophilic interaction chromatography with evaporative light scattering detection. J. Chromatogr. A 2005, 1092:246-249.
    • (2005) J. Chromatogr. A , vol.1092 , pp. 246-249
    • Karlsson, G.1    Winge, S.2    Sandberg, H.3
  • 61
    • 44349111701 scopus 로고    scopus 로고
    • Simultaneous determination of sugars and picrosides in Picrorhiza species using ultrasonic extraction and high-performance liquid chromatography with evaporative light scattering detection
    • Bhandari P., Kumar N., Singh B., Kaul V.K. Simultaneous determination of sugars and picrosides in Picrorhiza species using ultrasonic extraction and high-performance liquid chromatography with evaporative light scattering detection. J. Chromatogr. A 2008, 1194:257-261.
    • (2008) J. Chromatogr. A , vol.1194 , pp. 257-261
    • Bhandari, P.1    Kumar, N.2    Singh, B.3    Kaul, V.K.4
  • 62
    • 67649313530 scopus 로고    scopus 로고
    • Hyphenated ultra high-performance liquid chromatography-nano quantity analyte detector technique for determination of compounds with low UV absorption
    • Olšovská J., Kameník Z., Cajthamla T. Hyphenated ultra high-performance liquid chromatography-nano quantity analyte detector technique for determination of compounds with low UV absorption. J. Chromatogr. A 2009, 1216:5774-5778.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 5774-5778
    • Olšovská, J.1    Kameník, Z.2    Cajthamla, T.3
  • 66
    • 20044385589 scopus 로고    scopus 로고
    • A method for particle size amplification by water condensation in a laminar, thermally diffusive flow
    • Hering S.V., Stolzenburg M.R. A method for particle size amplification by water condensation in a laminar, thermally diffusive flow. Aerosol Sci. Technol. 2005, 39:428-436.
    • (2005) Aerosol Sci. Technol. , vol.39 , pp. 428-436
    • Hering, S.V.1    Stolzenburg, M.R.2
  • 70
    • 84875796410 scopus 로고    scopus 로고
    • Laboratory characterization of a new nano-water-based CPC 3788 and performance comparison to an ultrafine butanol-based CPC 3776
    • Kupc A., Bischof O., Tritscher T., Beeston M., Krinke T., Wagner P.E. Laboratory characterization of a new nano-water-based CPC 3788 and performance comparison to an ultrafine butanol-based CPC 3776. Aerosol Sci. Technol. 2013, 47:183-191.
    • (2013) Aerosol Sci. Technol. , vol.47 , pp. 183-191
    • Kupc, A.1    Bischof, O.2    Tritscher, T.3    Beeston, M.4    Krinke, T.5    Wagner, P.E.6
  • 71
    • 77953811578 scopus 로고    scopus 로고
    • Evidence for sub-3 nanometer neutralized particle detection using glycerol as a condensing fluid
    • Magnusson L.-E., Anisimov M.P., Koropchak J.A. Evidence for sub-3 nanometer neutralized particle detection using glycerol as a condensing fluid. J. Aerosol Sci. 2010, 41:637-654.
    • (2010) J. Aerosol Sci. , vol.41 , pp. 637-654
    • Magnusson, L.-E.1    Anisimov, M.P.2    Koropchak, J.A.3
  • 74
  • 77
    • 38049155700 scopus 로고    scopus 로고
    • On operation of the ultra-fine water-based CPC TSI 3786 and comparison with other TSI Models (TSI 3776, TSI 3772, TSI 3025, TSI 3010, TSI 3007)
    • Mordas G., Manninen H.E., Petäjä T., Aalto P.P., Hämeri K., Kulmala M. On operation of the ultra-fine water-based CPC TSI 3786 and comparison with other TSI Models (TSI 3776, TSI 3772, TSI 3025, TSI 3010, TSI 3007). Aerosol Sci. Technol. 2008, 42:152-158.
    • (2008) Aerosol Sci. Technol. , vol.42 , pp. 152-158
    • Mordas, G.1    Manninen, H.E.2    Petäjä, T.3    Aalto, P.P.4    Hämeri, K.5    Kulmala, M.6
  • 78
    • 20044384029 scopus 로고    scopus 로고
    • Performance evaluation of a recently developed water-based condensation particle counter
    • Biswas S., Fine P.M., Geller M.D., Hering S.V., Sioutas C. Performance evaluation of a recently developed water-based condensation particle counter. Aerosol Sci. Technol. 2005, 39:419-427.
    • (2005) Aerosol Sci. Technol. , vol.39 , pp. 419-427
    • Biswas, S.1    Fine, P.M.2    Geller, M.D.3    Hering, S.V.4    Sioutas, C.5
  • 80
    • 84919820425 scopus 로고    scopus 로고
    • A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection
    • Chemmalil L., Suravajjala S., See K., Jordan E., Furtado M., Sun C., Hosselet S. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection. J. Pharm. Sci. 2015, 104:15-24.
    • (2015) J. Pharm. Sci. , vol.104 , pp. 15-24
    • Chemmalil, L.1    Suravajjala, S.2    See, K.3    Jordan, E.4    Furtado, M.5    Sun, C.6    Hosselet, S.7
  • 81
    • 77956652295 scopus 로고    scopus 로고
    • Simultaneous determination of polysorbate 20 and unbound polyethylene-glycol in protein solutions using new core-shell reversed phase column and condensation nucleation light scattering detection
    • Fekete S., Ganzler K., Fekete J. Simultaneous determination of polysorbate 20 and unbound polyethylene-glycol in protein solutions using new core-shell reversed phase column and condensation nucleation light scattering detection. J. Chromatogr. A 2010, 1217:6258-6266.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 6258-6266
    • Fekete, S.1    Ganzler, K.2    Fekete, J.3
  • 82
    • 84977918525 scopus 로고    scopus 로고
    • Determination of kanamycin sulfate injection by HPLC-NQAD and HPLC-ELSD
    • Wang J.-F., Yang H.-X., Zhu L., Yin L.-H. Determination of kanamycin sulfate injection by HPLC-NQAD and HPLC-ELSD. Yaowu Fenxi Zazhi 2014, 34:644-648.
    • (2014) Yaowu Fenxi Zazhi , vol.34 , pp. 644-648
    • Wang, J.-F.1    Yang, H.-X.2    Zhu, L.3    Yin, L.-H.4
  • 83
    • 84874542136 scopus 로고    scopus 로고
    • Hydrophilic interaction chromatography with aerosol-based detectors (ELSD, CAD, NQAD) for polar compounds lacking a UV chromophore in an intravenous formulation
    • Cintrón J.M., Risley D.S. Hydrophilic interaction chromatography with aerosol-based detectors (ELSD, CAD, NQAD) for polar compounds lacking a UV chromophore in an intravenous formulation. J. Pharm. Biomed. Anal. 2013, 78-79:14-18.
    • (2013) J. Pharm. Biomed. Anal. , pp. 14-18
    • Cintrón, J.M.1    Risley, D.S.2
  • 84
    • 84874795018 scopus 로고    scopus 로고
    • Analysis of magnesium from magnesium stearate in pharmaceutical tablet formulations using hydrophilic interaction liquid chromatography with nano quantity analyte detection
    • Risley D.S., Magnusson L.-E., Morow P.R., Aburub A. Analysis of magnesium from magnesium stearate in pharmaceutical tablet formulations using hydrophilic interaction liquid chromatography with nano quantity analyte detection. J. Pharm. Biomed. Anal. 2013, 78-79:112-117.
    • (2013) J. Pharm. Biomed. Anal. , pp. 112-117
    • Risley, D.S.1    Magnusson, L.-E.2    Morow, P.R.3    Aburub, A.4
  • 85
    • 84862819081 scopus 로고    scopus 로고
    • Analysis of volatile bases by high performance liquid chromatography with aerosol-based detection
    • Cohen R.D., Liu Y., Gong X. Analysis of volatile bases by high performance liquid chromatography with aerosol-based detection. J. Chromatogr. A 2012, 1229:172-179.
    • (2012) J. Chromatogr. A , vol.1229 , pp. 172-179
    • Cohen, R.D.1    Liu, Y.2    Gong, X.3
  • 86
    • 79952068768 scopus 로고    scopus 로고
    • Comparison of the response of four aerosol detectors used with ultra high pressure liquid chromatography
    • Hutchinson J.P., Li J., Farrell W., Groeber E., Szucs R., Dicinoskia G., Haddad P.R. Comparison of the response of four aerosol detectors used with ultra high pressure liquid chromatography. J. Chromatogr. A 2011, 1218:1646-1655.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 1646-1655
    • Hutchinson, J.P.1    Li, J.2    Farrell, W.3    Groeber, E.4    Szucs, R.5    Dicinoskia, G.6    Haddad, P.R.7
  • 87
    • 77955906192 scopus 로고    scopus 로고
    • Alternatives to amino acid analysis for the purity control of pharmaceutical grade l-alanine
    • Holzgrabe U., Nap C.-J., Beyer T., Almeling S. Alternatives to amino acid analysis for the purity control of pharmaceutical grade l-alanine. J. Sep. Sci. 2010, 33:2402-2410.
    • (2010) J. Sep. Sci. , vol.33 , pp. 2402-2410
    • Holzgrabe, U.1    Nap, C.-J.2    Beyer, T.3    Almeling, S.4
  • 89
    • 72449168034 scopus 로고    scopus 로고
    • Control of impurities in l-aspartic acid and l-alanine by high-performance liquid chromatography coupled with a corona charged aerosol detector
    • Holzgrabe U., Nap C.-J., Almeling S. Control of impurities in l-aspartic acid and l-alanine by high-performance liquid chromatography coupled with a corona charged aerosol detector. J. Chromatogr. A 2010, 1217:294-301.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 294-301
    • Holzgrabe, U.1    Nap, C.-J.2    Almeling, S.3
  • 92
    • 84885032844 scopus 로고    scopus 로고
    • Quantification of triacylglycerol molecular species in cocoa butter using high-performance liquid chromatography equipped with nano quantity analyte detector
    • Beppu F., Nagai T., Yoshinaga K., Mizobe H., Kojima K., Gotoh N. Quantification of triacylglycerol molecular species in cocoa butter using high-performance liquid chromatography equipped with nano quantity analyte detector. J. Oleo Sci. 2013, 10:789-794.
    • (2013) J. Oleo Sci. , vol.10 , pp. 789-794
    • Beppu, F.1    Nagai, T.2    Yoshinaga, K.3    Mizobe, H.4    Kojima, K.5    Gotoh, N.6
  • 94
    • 0034906235 scopus 로고    scopus 로고
    • Investigation of the condensation nucleation light scattering detector (CNLSD) for carbohydrates with ion-exchange and hydrophilic interaction separations
    • Wang Q., Sadain S., Koropchak J.A. Investigation of the condensation nucleation light scattering detector (CNLSD) for carbohydrates with ion-exchange and hydrophilic interaction separations. Am. Biotechnol. Lab. 2001, 19:22-24.
    • (2001) Am. Biotechnol. Lab. , vol.19 , pp. 22-24
    • Wang, Q.1    Sadain, S.2    Koropchak, J.A.3
  • 96
    • 0037436364 scopus 로고    scopus 로고
    • Condensation nucleation light scattering detection with ion chromatography for direct determination of glyphosate and its metabolite in water
    • You J., Koropchak J.A. Condensation nucleation light scattering detection with ion chromatography for direct determination of glyphosate and its metabolite in water. J. Chromatogr. A 2003, 989:231-238.
    • (2003) J. Chromatogr. A , vol.989 , pp. 231-238
    • You, J.1    Koropchak, J.A.2
  • 99
    • 75949115741 scopus 로고    scopus 로고
    • Review of operating principle and applications of the charged aerosol detector
    • Vehovec T., Obreza A. Review of operating principle and applications of the charged aerosol detector. J. Chromatogr. A 2010, 1217:1549-1556.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 1549-1556
    • Vehovec, T.1    Obreza, A.2
  • 100
  • 101
    • 79952996038 scopus 로고    scopus 로고
    • Aerosol-based detectors for liquid chromatography: do they have a role in bioanalysis?
    • Dixon R.W. Aerosol-based detectors for liquid chromatography: do they have a role in bioanalysis?. Bioanalysis 2009, 1(8):1389-1392.
    • (2009) Bioanalysis , vol.1 , Issue.8 , pp. 1389-1392
    • Dixon, R.W.1
  • 103
    • 41949101294 scopus 로고    scopus 로고
    • Performance evaluation of evaporative light scattering detection and charged aerosol detection in reversed phase liquid chromatography
    • Vervoort N., Daemen D., Torok G. Performance evaluation of evaporative light scattering detection and charged aerosol detection in reversed phase liquid chromatography. J. Chromatogr. A 2008, 1189:92-100.
    • (2008) J. Chromatogr. A , vol.1189 , pp. 92-100
    • Vervoort, N.1    Daemen, D.2    Torok, G.3
  • 104
    • 84960546095 scopus 로고    scopus 로고
    • Nebulizer for charged aerosol detection (CAD) system, United States Application
    • A.D. Yim, P.H. Gamache, R.S. McCarthy, Nebulizer for charged aerosol detection (CAD) system, United States Patent Application 0352411 A1 (2014).
    • (2014)
    • Yim, A.D.1    Gamache, P.H.2    McCarthy, R.S.3
  • 105
    • 53749095319 scopus 로고    scopus 로고
    • Analysis of quaternary ammonium and phosphonium ionic liquids by reversed-phase high-performance liquid chromatography with charged aerosol detection and unified calibration
    • Stojanovic A., Lammerhofer M., Kogelnig D., Schiesel S., Sturm M., Galanski M., Krachler R., Keppler B., Lindner W. Analysis of quaternary ammonium and phosphonium ionic liquids by reversed-phase high-performance liquid chromatography with charged aerosol detection and unified calibration. J. Chromatogr. A 2008, 1209:179-187.
    • (2008) J. Chromatogr. A , vol.1209 , pp. 179-187
    • Stojanovic, A.1    Lammerhofer, M.2    Kogelnig, D.3    Schiesel, S.4    Sturm, M.5    Galanski, M.6    Krachler, R.7    Keppler, B.8    Lindner, W.9
  • 106
    • 84924262840 scopus 로고    scopus 로고
    • Effects of densities of brominated flame retardants on the detection response for HPLC analysis with a corona-charged aerosol detector
    • Matsuyama S., Orihara Y., Kinugasa S., Ohtani H. Effects of densities of brominated flame retardants on the detection response for HPLC analysis with a corona-charged aerosol detector. Anal. Sci. 2015, 31:61-65.
    • (2015) Anal. Sci. , vol.31 , pp. 61-65
    • Matsuyama, S.1    Orihara, Y.2    Kinugasa, S.3    Ohtani, H.4
  • 107
    • 0002815398 scopus 로고
    • An experiment on the atomization of liquid. IV. The effect of the properties of liquid on the size of drops
    • Nukiyama S., Tanasawa Y. An experiment on the atomization of liquid. IV. The effect of the properties of liquid on the size of drops. Trans. Soc. Mech. Eng. Jpn. 1939, 5:68-75.
    • (1939) Trans. Soc. Mech. Eng. Jpn. , vol.5 , pp. 68-75
    • Nukiyama, S.1    Tanasawa, Y.2
  • 108
    • 33646584837 scopus 로고    scopus 로고
    • Universal response in liquid chromatography using charged aerosol detection
    • Gorecki T., Lynen F., Szucs R., Sandra P. Universal response in liquid chromatography using charged aerosol detection. Anal. Chem. 2006, 78:3186-3192.
    • (2006) Anal. Chem. , vol.78 , pp. 3186-3192
    • Gorecki, T.1    Lynen, F.2    Szucs, R.3    Sandra, P.4
  • 109
    • 84907271563 scopus 로고    scopus 로고
    • Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors
    • Khandagale M.M., Hilder E., Shellie R.A., Haddad P.R. Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors. J. Chromatogr. A 2014, 1356:180-187.
    • (2014) J. Chromatogr. A , vol.1356 , pp. 180-187
    • Khandagale, M.M.1    Hilder, E.2    Shellie, R.A.3    Haddad, P.R.4
  • 110
    • 33749647656 scopus 로고    scopus 로고
    • The analysis of lipids via HPLC with a charged aerosol detector
    • Moreau R.A. The analysis of lipids via HPLC with a charged aerosol detector. Lipids 2006, 41:727-734.
    • (2006) Lipids , vol.41 , pp. 727-734
    • Moreau, R.A.1
  • 111
    • 84866330083 scopus 로고    scopus 로고
    • Comprehensive impurity profiling of nutritional infusion solutions by multidimensional off-line reversed-phase liquid chromatography × hydrophilic interaction chromatography-ion trap mass-spectrometry and charged aerosol detection with universal calibration
    • Schiesel S., Lammerhofer M., Lindner W. Comprehensive impurity profiling of nutritional infusion solutions by multidimensional off-line reversed-phase liquid chromatography × hydrophilic interaction chromatography-ion trap mass-spectrometry and charged aerosol detection with universal calibration. J. Chromatogr. A 2012, 1259:100-110.
    • (2012) J. Chromatogr. A , vol.1259 , pp. 100-110
    • Schiesel, S.1    Lammerhofer, M.2    Lindner, W.3
  • 112
    • 84875371459 scopus 로고    scopus 로고
    • Evaluation of charged aerosol detector for purity assessment of protein
    • Wang R., Wang X., Paulino J., Alquier L. Evaluation of charged aerosol detector for purity assessment of protein. J. Chromatogr. A 2013, 1283:116-121.
    • (2013) J. Chromatogr. A , vol.1283 , pp. 116-121
    • Wang, R.1    Wang, X.2    Paulino, J.3    Alquier, L.4
  • 113
    • 84884269747 scopus 로고    scopus 로고
    • Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection
    • Zhang K., Li Y., Tsang M., Chetwyn N.P. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection. J. Sep. Sci. 2013, 36:2986-2992.
    • (2013) J. Sep. Sci. , vol.36 , pp. 2986-2992
    • Zhang, K.1    Li, Y.2    Tsang, M.3    Chetwyn, N.P.4
  • 114
    • 84896323106 scopus 로고    scopus 로고
    • Impurity profiling of carbocisteine by HPLC-CAD, qNMR and UV/vis spectroscopy
    • Wahl O., Holzgrabe U. Impurity profiling of carbocisteine by HPLC-CAD, qNMR and UV/vis spectroscopy. J. Pharm. Biomed. Anal. 2014, 95:1-10.
    • (2014) J. Pharm. Biomed. Anal. , vol.95 , pp. 1-10
    • Wahl, O.1    Holzgrabe, U.2
  • 116
    • 84884714810 scopus 로고    scopus 로고
    • Determination of water-soluble vitamins in infant milk and dietary supplement using a liquid chromatography on-line coupled to a corona-charged aerosol detector
    • Marquez-Sillero I., Cardenas S., Valcarcel M. Determination of water-soluble vitamins in infant milk and dietary supplement using a liquid chromatography on-line coupled to a corona-charged aerosol detector. J. Chromatogr. A 2013, 1313:253-258.
    • (2013) J. Chromatogr. A , vol.1313 , pp. 253-258
    • Marquez-Sillero, I.1    Cardenas, S.2    Valcarcel, M.3
  • 117
    • 84892725035 scopus 로고    scopus 로고
    • Quantification of individual phenolic compounds' contribution to antioxidant capacity in apple: a novel analytical tool based on liquid chromatography with diode array, electrochemical, and charged aerosol detection
    • Plaza M., Kaiuki J., Turner C. Quantification of individual phenolic compounds' contribution to antioxidant capacity in apple: a novel analytical tool based on liquid chromatography with diode array, electrochemical, and charged aerosol detection. J. Agric. Food Chem. 2014, 62:409-418.
    • (2014) J. Agric. Food Chem. , vol.62 , pp. 409-418
    • Plaza, M.1    Kaiuki, J.2    Turner, C.3
  • 118
    • 84905718015 scopus 로고    scopus 로고
    • Determination of inulin-type fructooligosaccharides in edible plants by high-performance liquid chromatography with charged aerosol detector
    • Li J., Hu D., Zong W., Lv G., Zhao J., Li S. Determination of inulin-type fructooligosaccharides in edible plants by high-performance liquid chromatography with charged aerosol detector. J. Agric. Food Chem. 2014, 62:7707-7713.
    • (2014) J. Agric. Food Chem. , vol.62 , pp. 7707-7713
    • Li, J.1    Hu, D.2    Zong, W.3    Lv, G.4    Zhao, J.5    Li, S.6
  • 119
    • 58649092615 scopus 로고    scopus 로고
    • Aerosol based detectors for the investigation of phospholipid hydrolysis in a pharmaceutical suspension formulation
    • Nair L.M., Werling J.O. Aerosol based detectors for the investigation of phospholipid hydrolysis in a pharmaceutical suspension formulation. J. Pharm. Biomed. Anal. 2009, 49:95-99.
    • (2009) J. Pharm. Biomed. Anal. , vol.49 , pp. 95-99
    • Nair, L.M.1    Werling, J.O.2
  • 120
    • 84894088921 scopus 로고    scopus 로고
    • Determination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector
    • Poplawska M., Blazewicz A., Zolek P., Fijalek Z. Determination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector. J. Pharm. Biomed. Anal. 2014, 94:45-53.
    • (2014) J. Pharm. Biomed. Anal. , vol.94 , pp. 45-53
    • Poplawska, M.1    Blazewicz, A.2    Zolek, P.3    Fijalek, Z.4
  • 121
    • 66649138259 scopus 로고    scopus 로고
    • Size exclusion chromatography with corona charged aerosol detector for the analysis of polyethylene glycol polymer
    • Kou D., Manius G., Zhan S., Chokshi H.P. Size exclusion chromatography with corona charged aerosol detector for the analysis of polyethylene glycol polymer. J. Chromatogr. A 2009, 1216:5424-5428.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 5424-5428
    • Kou, D.1    Manius, G.2    Zhan, S.3    Chokshi, H.P.4
  • 122
    • 84892778738 scopus 로고    scopus 로고
    • Chromatographic methods for characterization of poly (ethylene glycol)-modified polyamidoamine dendrimers
    • Park E.J., Choo H., Kim S.W., Na D.H. Chromatographic methods for characterization of poly (ethylene glycol)-modified polyamidoamine dendrimers. Anal. Biochem. 2014, 449:42-44.
    • (2014) Anal. Biochem. , vol.449 , pp. 42-44
    • Park, E.J.1    Choo, H.2    Kim, S.W.3    Na, D.H.4
  • 123
    • 0032040826 scopus 로고    scopus 로고
    • History of electrical aerosol measurements
    • Flagan R.C. History of electrical aerosol measurements. Aerosol Sci. Technol. 1998, 28:301-380.
    • (1998) Aerosol Sci. Technol. , vol.28 , pp. 301-380
    • Flagan, R.C.1
  • 124
    • 84863012706 scopus 로고    scopus 로고
    • Modification of laminar flow ultrafine condensation particle counters for the enhanced detection of 1 nm condensation nuclei
    • Kuang C., Chen M., McMurry P.H., Wang J. Modification of laminar flow ultrafine condensation particle counters for the enhanced detection of 1 nm condensation nuclei. Aerosol Sci. Technol. 2012, 46:309-315.
    • (2012) Aerosol Sci. Technol. , vol.46 , pp. 309-315
    • Kuang, C.1    Chen, M.2    McMurry, P.H.3    Wang, J.4
  • 125
    • 0034057192 scopus 로고    scopus 로고
    • A condensation nucleus counter (CNC) sensitive to singly charged sub-nanometer particles
    • Gamero-Castano M., Fernandez de la Mora J. A condensation nucleus counter (CNC) sensitive to singly charged sub-nanometer particles. J. Aerosol Sci. 2000, 31:757-772.
    • (2000) J. Aerosol Sci. , vol.31 , pp. 757-772
    • Gamero-Castano, M.1    Fernandez de la Mora, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.