메뉴 건너뛰기




Volumn 30, Issue 6, 2014, Pages 619-634

Micro-CT of rodents: State-of-the-art and future perspectives

Author keywords

Bone; Heart; Lung; Micro CT; Nanoparticles; Rodents; Tumors; X ray

Indexed keywords

IOHEXOL; IOPAMIDOL; CONTRAST MEDIUM;

EID: 84906233069     PISSN: 11201797     EISSN: 1724191X     Source Type: Journal    
DOI: 10.1016/j.ejmp.2014.05.011     Document Type: Review
Times cited : (179)

References (193)
  • 1
    • 0036680539 scopus 로고    scopus 로고
    • Micro-CT in small animal and specimen imaging
    • Holdsworth D.W., Thornton M. Micro-CT in small animal and specimen imaging. Trends Biotechnol 2002, 20(8):S34-39.
    • (2002) Trends Biotechnol , vol.20 , Issue.8
    • Holdsworth, D.W.1    Thornton, M.2
  • 3
    • 42949159662 scopus 로고    scopus 로고
    • Geometric calibration for a dual tube/detector micro-CT system
    • Johnston S.M., Johnson G.A., Badea C.T. Geometric calibration for a dual tube/detector micro-CT system. Med Phys 2008, 35(5):1820-1829.
    • (2008) Med Phys , vol.35 , Issue.5 , pp. 1820-1829
    • Johnston, S.M.1    Johnson, G.A.2    Badea, C.T.3
  • 4
    • 11244304503 scopus 로고    scopus 로고
    • Micro-CT with respiratory and cardiac gating
    • Badea C.T., Hedlund L.W., Johnson G.A. Micro-CT with respiratory and cardiac gating. Med Phys 2004, 31(12):3324-3329.
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3324-3329
    • Badea, C.T.1    Hedlund, L.W.2    Johnson, G.A.3
  • 5
    • 41449104123 scopus 로고    scopus 로고
    • A registration-based approach for cardiac micro-CT using combined prospective and retrospective gating
    • Badea C.T., Schreibmann E., Fox T. A registration-based approach for cardiac micro-CT using combined prospective and retrospective gating. Med Phys 2008, 35(4):1170-1179.
    • (2008) Med Phys , vol.35 , Issue.4 , pp. 1170-1179
    • Badea, C.T.1    Schreibmann, E.2    Fox, T.3
  • 6
    • 77957690714 scopus 로고    scopus 로고
    • Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray
    • Cao G., Burk L.M., Lee Y.Z., Calderon-Colon X., Sultana S., Lu J., et al. Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray. Med Phys 2010, 37(10):5306-5312.
    • (2010) Med Phys , vol.37 , Issue.10 , pp. 5306-5312
    • Cao, G.1    Burk, L.M.2    Lee, Y.Z.3    Calderon-Colon, X.4    Sultana, S.5    Lu, J.6
  • 7
    • 64649105918 scopus 로고    scopus 로고
    • A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source
    • Cao G., Lee Y.Z., Peng R., Liu Z., Rajaram R., Calderon-Colon X., et al. A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source. Phys Med Biology 2009, 54(8):2323.
    • (2009) Phys Med Biology , vol.54 , Issue.8 , pp. 2323
    • Cao, G.1    Lee, Y.Z.2    Peng, R.3    Liu, Z.4    Rajaram, R.5    Calderon-Colon, X.6
  • 8
    • 79956044491 scopus 로고    scopus 로고
    • Generation of continuous and pulsed diagnostic imaging x-ray radiation using a carbon-nanotube-based field-emission cathode
    • Yue G., Qiu Q., Gao B., Cheng Y., Zhang J., Shimoda H., et al. Generation of continuous and pulsed diagnostic imaging x-ray radiation using a carbon-nanotube-based field-emission cathode. Appl Phys Lett 2002, 81(2):355-357.
    • (2002) Appl Phys Lett , vol.81 , Issue.2 , pp. 355-357
    • Yue, G.1    Qiu, Q.2    Gao, B.3    Cheng, Y.4    Zhang, J.5    Shimoda, H.6
  • 9
    • 0022908658 scopus 로고
    • Electron beam melting in microfocus X-ray tubes
    • Grider D.E., Wright A., Ausburn P.K. Electron beam melting in microfocus X-ray tubes. J Phys D Appl Phys 1986, 19(12):2281.
    • (1986) J Phys D Appl Phys , vol.19 , Issue.12 , pp. 2281
    • Grider, D.E.1    Wright, A.2    Ausburn, P.K.3
  • 10
    • 0029702201 scopus 로고    scopus 로고
    • Influence of heel effect and of nonuniformity of emitted spectra on dual-energy subtraction in computed radiography
    • Fivez C.M., Wambacq P., Suetens P., Schoeters E.P. Influence of heel effect and of nonuniformity of emitted spectra on dual-energy subtraction in computed radiography. Proc SPIE 1996, 2708:588-598.
    • (1996) Proc SPIE , vol.2708 , pp. 588-598
    • Fivez, C.M.1    Wambacq, P.2    Suetens, P.3    Schoeters, E.P.4
  • 13
    • 78650208723 scopus 로고    scopus 로고
    • Angioarchitectural changes in subacute cerebral venous thrombosis. A synchrotron-based micro- and nano-CT study
    • Stolz E., Yeniguen M., Kreisel M., Kampschulte M., Doenges S., Sedding D., et al. Angioarchitectural changes in subacute cerebral venous thrombosis. A synchrotron-based micro- and nano-CT study. NeuroImage 2011, 54(3):1881-1886.
    • (2011) NeuroImage , vol.54 , Issue.3 , pp. 1881-1886
    • Stolz, E.1    Yeniguen, M.2    Kreisel, M.3    Kampschulte, M.4    Doenges, S.5    Sedding, D.6
  • 14
    • 0018877478 scopus 로고
    • High-resolution computed tomography of the normal rat nephrogram
    • Kujoory M.A., Hillman B.J., Barrett H.H. High-resolution computed tomography of the normal rat nephrogram. Invest Radiol 1980, 15(2):148-154.
    • (1980) Invest Radiol , vol.15 , Issue.2 , pp. 148-154
    • Kujoory, M.A.1    Hillman, B.J.2    Barrett, H.H.3
  • 15
    • 0024589979 scopus 로고
    • The direct examination of three-dimensional bone architecture in vitro by computed tomography
    • Feldkamp L.A., Goldstein S.A., Parfitt A.M., Jesion G., Kleerekoper M. The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 1989, 4(1):3-11.
    • (1989) J Bone Miner Res , vol.4 , Issue.1 , pp. 3-11
    • Feldkamp, L.A.1    Goldstein, S.A.2    Parfitt, A.M.3    Jesion, G.4    Kleerekoper, M.5
  • 16
    • 0027205207 scopus 로고
    • A high-resolution XRII-based quantitative volume CT scanner
    • Holdsworth D.W., Drangova M., Fenster A. A high-resolution XRII-based quantitative volume CT scanner. Med Phys 1993, 20(2 Pt 1):449-462.
    • (1993) Med Phys , vol.20 , Issue.2 PART 1 , pp. 449-462
    • Holdsworth, D.W.1    Drangova, M.2    Fenster, A.3
  • 17
    • 0027881707 scopus 로고
    • A fluoroscopy-based computed tomography scanner for small specimen research
    • Boone J.M., Alexander G.M., Seibert J.A. A fluoroscopy-based computed tomography scanner for small specimen research. Invest Radiol 1993, 28(6):539-544.
    • (1993) Invest Radiol , vol.28 , Issue.6 , pp. 539-544
    • Boone, J.M.1    Alexander, G.M.2    Seibert, J.A.3
  • 18
    • 0034088968 scopus 로고    scopus 로고
    • High resolution X-ray computed tomography: an emerging tool for small animal cancer research
    • Paulus M.J., Gleason S.S., Kennel S.J., Hunsicker P.R., Johnson D.K. High resolution X-ray computed tomography: an emerging tool for small animal cancer research. Neoplasia 2000, 2(1-2):62-70.
    • (2000) Neoplasia , vol.2 , Issue.1-2 , pp. 62-70
    • Paulus, M.J.1    Gleason, S.S.2    Kennel, S.J.3    Hunsicker, P.R.4    Johnson, D.K.5
  • 20
    • 0347597904 scopus 로고    scopus 로고
    • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
    • Lee S.C., Kim H.K., Chun I.K., Cho M.H., Lee S.Y., Cho M.H. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol 2003, 48(24):4173-4185.
    • (2003) Phys Med Biol , vol.48 , Issue.24 , pp. 4173-4185
    • Lee, S.C.1    Kim, H.K.2    Chun, I.K.3    Cho, M.H.4    Lee, S.Y.5    Cho, M.H.6
  • 21
    • 35349003753 scopus 로고    scopus 로고
    • Flat-detector computed tomography (FD-CT)
    • Kalender W.A., Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol 2007, 17(11):2767-2779.
    • (2007) Eur Radiol , vol.17 , Issue.11 , pp. 2767-2779
    • Kalender, W.A.1    Kyriakou, Y.2
  • 24
    • 84891548259 scopus 로고    scopus 로고
    • Vision 20/20: single photon counting x-ray detectors in medical imaging
    • Taguchi K., Iwanczyk J.S. Vision 20/20: single photon counting x-ray detectors in medical imaging. Med Phys 2013, 40(10):100901.
    • (2013) Med Phys , vol.40 , Issue.10 , pp. 100901
    • Taguchi, K.1    Iwanczyk, J.S.2
  • 25
    • 79952122674 scopus 로고    scopus 로고
    • Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion
    • Taguchi K., Xu J., Srivastava S., Tsui B.M., Cammin J., Tang Q. Interior region-of-interest reconstruction using a small, nearly piecewise constant subregion. Med Phys 2011, 38(3):1307-1312.
    • (2011) Med Phys , vol.38 , Issue.3 , pp. 1307-1312
    • Taguchi, K.1    Xu, J.2    Srivastava, S.3    Tsui, B.M.4    Cammin, J.5    Tang, Q.6
  • 26
    • 77949704874 scopus 로고    scopus 로고
    • Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    • Bornefalk H., Danielsson M. Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study. Phys Med Biol 2010, 55(7):1999-2022.
    • (2010) Phys Med Biol , vol.55 , Issue.7 , pp. 1999-2022
    • Bornefalk, H.1    Danielsson, M.2
  • 29
    • 51849131434 scopus 로고    scopus 로고
    • In vivo small-animal imaging using micro-CT and digital subtraction angiography
    • Badea C., Drangova M., Holdsworth D., Johnson G. In vivo small-animal imaging using micro-CT and digital subtraction angiography. Phys Med Biol 2008, 53:R319.
    • (2008) Phys Med Biol , vol.53
    • Badea, C.1    Drangova, M.2    Holdsworth, D.3    Johnson, G.4
  • 30
    • 33846189786 scopus 로고    scopus 로고
    • Fast Retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice
    • Drangova M., Ford N.L., Detombe S.A., Wheatley A.R., Holdsworth D.W. Fast Retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice. Invest Radiol 2007, 42(2):85-94.
    • (2007) Invest Radiol , vol.42 , Issue.2 , pp. 85-94
    • Drangova, M.1    Ford, N.L.2    Detombe, S.A.3    Wheatley, A.R.4    Holdsworth, D.W.5
  • 33
    • 84858262440 scopus 로고    scopus 로고
    • Analysis of image sharpness reproducibility on a novel engineered micro-CT scanner with variable geometry and embedded recalibration software
    • Panetta D., Belcari N., Del Guerra A., Bartolomei A., Salvadori P. Analysis of image sharpness reproducibility on a novel engineered micro-CT scanner with variable geometry and embedded recalibration software. Physica Medica 2012, 28(2):166-173.
    • (2012) Physica Medica , vol.28 , Issue.2 , pp. 166-173
    • Panetta, D.1    Belcari, N.2    Del Guerra, A.3    Bartolomei, A.4    Salvadori, P.5
  • 34
    • 47649113588 scopus 로고    scopus 로고
    • An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms
    • Panetta D., Belcari N., Del Guerra A., Moehrs S. An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms. Phys Med Biol 2008, 53(14):3841-3861.
    • (2008) Phys Med Biol , vol.53 , Issue.14 , pp. 3841-3861
    • Panetta, D.1    Belcari, N.2    Del Guerra, A.3    Moehrs, S.4
  • 35
    • 84864691298 scopus 로고    scopus 로고
    • Image features for misalignment correction in medical flat-detector CT
    • Wicklein J., Kunze H., Kalender W.A., Kyriakou Y. Image features for misalignment correction in medical flat-detector CT. Med Phys 2012, 39(8):4918-4931.
    • (2012) Med Phys , vol.39 , Issue.8 , pp. 4918-4931
    • Wicklein, J.1    Kunze, H.2    Kalender, W.A.3    Kyriakou, Y.4
  • 36
    • 0035288499 scopus 로고    scopus 로고
    • A review of high-resolution X-ray computed tomography and other imaging modalities for small animal research
    • Paulus M.J., Gleason S.S., Easterly M.E., Foltz C.J. A review of high-resolution X-ray computed tomography and other imaging modalities for small animal research. Lab Anim (NY) 2001, 30(3):36-45.
    • (2001) Lab Anim (NY) , vol.30 , Issue.3 , pp. 36-45
    • Paulus, M.J.1    Gleason, S.S.2    Easterly, M.E.3    Foltz, C.J.4
  • 38
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • Tuy H. An inversion formula for cone-beam reconstruction. SIAM J Appl Math 1983, 43:546-562.
    • (1983) SIAM J Appl Math , vol.43 , pp. 546-562
    • Tuy, H.1
  • 39
    • 0029045599 scopus 로고
    • Filtered backprojection reconstruction of combined parallel beam and cone beam SPECT data
    • Defrise M., Clack R. Filtered backprojection reconstruction of combined parallel beam and cone beam SPECT data. Phys Med Biol 1995, 40(9):1517-1537.
    • (1995) Phys Med Biol , vol.40 , Issue.9 , pp. 1517-1537
    • Defrise, M.1    Clack, R.2
  • 40
    • 0014905513 scopus 로고
    • Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography
    • Gordon R., Bender R., Herman G.T. Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. J Theor Biol 1970, 29:471-481.
    • (1970) J Theor Biol , vol.29 , pp. 471-481
    • Gordon, R.1    Bender, R.2    Herman, G.T.3
  • 41
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin L.I., Osher S., Fatemi E. Nonlinear total variation based noise removal algorithms. Physica D 1992, 60:259-268.
    • (1992) Physica D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 42
    • 35648981849 scopus 로고    scopus 로고
    • Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
    • Song J., Liu Q.H., Johnson G.A., Badea C.T. Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. Med Phys 2007, 34(11):4476-4483.
    • (2007) Med Phys , vol.34 , Issue.11 , pp. 4476-4483
    • Song, J.1    Liu, Q.H.2    Johnson, G.A.3    Badea, C.T.4
  • 43
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • Elbakri I.A., Fessler J.A. Statistical image reconstruction for polyenergetic X-ray computed tomography. IEEE Trans Med Imaging 2002, 21:89-99.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 89-99
    • Elbakri, I.A.1    Fessler, J.A.2
  • 44
    • 34249649611 scopus 로고    scopus 로고
    • Real-time 3D computed tomographic reconstruction using commodity graphics hardware
    • Xu F., Mueller K. Real-time 3D computed tomographic reconstruction using commodity graphics hardware. Phys Med Biol 2007, 52(12):3405-3419.
    • (2007) Phys Med Biol , vol.52 , Issue.12 , pp. 3405-3419
    • Xu, F.1    Mueller, K.2
  • 46
    • 79955784783 scopus 로고    scopus 로고
    • GPU-based iterative reconstruction with total variation minimization for micro-CT
    • Johnston S.M., Johnson G.A., Badea C.T. GPU-based iterative reconstruction with total variation minimization for micro-CT. Proc. SPIE 2010, 7622:762238.
    • (2010) Proc. SPIE , vol.7622 , pp. 762238
    • Johnston, S.M.1    Johnson, G.A.2    Badea, C.T.3
  • 49
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelriess M., Sennst D.A., Maxlmoser W., Kalender W.A. Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 2002, 29(7):1489-1503.
    • (2002) Med Phys , vol.29 , Issue.7 , pp. 1489-1503
    • Kachelriess, M.1    Sennst, D.A.2    Maxlmoser, W.3    Kalender, W.A.4
  • 50
    • 70350077433 scopus 로고    scopus 로고
    • Intrinsic gating for small-animal computed tomography a robust ECG-less paradigm for deriving cardiac phase information and functional imaging
    • Dinkel J., Bartling S.H., Kuntz J., Grasruck M., Kopp-Schneider A., Iwasaki M., et al. Intrinsic gating for small-animal computed tomography a robust ECG-less paradigm for deriving cardiac phase information and functional imaging. Circulation-Cardiovascular Imaging 2008, 1(3):235-243.
    • (2008) Circulation-Cardiovascular Imaging , vol.1 , Issue.3 , pp. 235-243
    • Dinkel, J.1    Bartling, S.H.2    Kuntz, J.3    Grasruck, M.4    Kopp-Schneider, A.5    Iwasaki, M.6
  • 52
    • 79952162862 scopus 로고    scopus 로고
    • Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals
    • Sawall S., Bergner F., Lapp R., Mronz M., Karolczak M., Hess A., et al. Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals. Med Phys 2011, 38(3):1416-1424.
    • (2011) Med Phys , vol.38 , Issue.3 , pp. 1416-1424
    • Sawall, S.1    Bergner, F.2    Lapp, R.3    Mronz, M.4    Karolczak, M.5    Hess, A.6
  • 53
    • 33646466639 scopus 로고    scopus 로고
    • Virtual histology of transgenic mouse embryos for high-throughput phenotyping
    • Johnson J.T., Hansen M.S., Wu I., Healy L.J., Johnson C.R., Jones G.M., et al. Virtual histology of transgenic mouse embryos for high-throughput phenotyping. PLoS Genet 2006, 2(4):e61.
    • (2006) PLoS Genet , vol.2 , Issue.4
    • Johnson, J.T.1    Hansen, M.S.2    Wu, I.3    Healy, L.J.4    Johnson, C.R.5    Jones, G.M.6
  • 54
    • 61649124483 scopus 로고    scopus 로고
    • MicroCT for developmental biology: a versatile tool for high-contrast 3D imaging at histological resolutions
    • Metscher B.D. MicroCT for developmental biology: a versatile tool for high-contrast 3D imaging at histological resolutions. Dev Dyn 2009, 238(3):632-640.
    • (2009) Dev Dyn , vol.238 , Issue.3 , pp. 632-640
    • Metscher, B.D.1
  • 55
    • 68749106020 scopus 로고    scopus 로고
    • MicroCT for comparative morphology: simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues
    • Metscher B.D. MicroCT for comparative morphology: simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues. BMC Physiol 2009, 9:11.
    • (2009) BMC Physiol , vol.9 , pp. 11
    • Metscher, B.D.1
  • 56
    • 39749124359 scopus 로고    scopus 로고
    • A high precision contrast injector for small animal x-ray digital subtraction angiography
    • Lin M.D., Ning L., Badea C.T., Mistry N.N., Qi Y., Johnson G.A. A high precision contrast injector for small animal x-ray digital subtraction angiography. IEEE Trans Biomed Eng 2008, 2008(3):1082-1091.
    • (2008) IEEE Trans Biomed Eng , vol.2008 , Issue.3 , pp. 1082-1091
    • Lin, M.D.1    Ning, L.2    Badea, C.T.3    Mistry, N.N.4    Qi, Y.5    Johnson, G.A.6
  • 57
    • 84893826427 scopus 로고    scopus 로고
    • Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent
    • Ashton J.R., Befera N., Clark D., Qi Y., Mao L., Rockman H.A., et al. Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent. Contrast Media Mol Imaging 2014, 9(2):161-168.
    • (2014) Contrast Media Mol Imaging , vol.9 , Issue.2 , pp. 161-168
    • Ashton, J.R.1    Befera, N.2    Clark, D.3    Qi, Y.4    Mao, L.5    Rockman, H.A.6
  • 59
    • 31544450749 scopus 로고    scopus 로고
    • Recent advances in X-ray phase imaging
    • Momose A. Recent advances in X-ray phase imaging. Jpn J Appl Phys 2005, 44(9R):6355.
    • (2005) Jpn J Appl Phys , vol.44 , Issue.9 R , pp. 6355
    • Momose, A.1
  • 61
    • 79952365137 scopus 로고    scopus 로고
    • The genetic background effect on domesticated species: a mouse evolutionary perspective
    • Reuveni E. The genetic background effect on domesticated species: a mouse evolutionary perspective. ScientificWorld Journal 2011, 11:429-436.
    • (2011) ScientificWorld Journal , vol.11 , pp. 429-436
    • Reuveni, E.1
  • 63
    • 84863896802 scopus 로고    scopus 로고
    • Syntheses and characterization of lisinopril-coated gold nanoparticles as highly stable targeted CT contrast agents in cardiovascular diseases
    • Ghann W.E., Aras O., Fleiter T., Daniel M.C. Syntheses and characterization of lisinopril-coated gold nanoparticles as highly stable targeted CT contrast agents in cardiovascular diseases. Langmuir 2012, 28(28):10398-10408.
    • (2012) Langmuir , vol.28 , Issue.28 , pp. 10398-10408
    • Ghann, W.E.1    Aras, O.2    Fleiter, T.3    Daniel, M.C.4
  • 64
    • 79952487639 scopus 로고    scopus 로고
    • An effective strategy for the synthesis of biocompatible gold nanoparticles using cinnamon phytochemicals for phantom CT imaging and photoacoustic detection of cancerous cells
    • Chanda N., Shukla R., Zambre A., Mekapothula S., Kulkarni R.R., Katti K., et al. An effective strategy for the synthesis of biocompatible gold nanoparticles using cinnamon phytochemicals for phantom CT imaging and photoacoustic detection of cancerous cells. Pharm Res 2011, 28(2):279-291.
    • (2011) Pharm Res , vol.28 , Issue.2 , pp. 279-291
    • Chanda, N.1    Shukla, R.2    Zambre, A.3    Mekapothula, S.4    Kulkarni, R.R.5    Katti, K.6
  • 65
    • 77956104408 scopus 로고    scopus 로고
    • Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles
    • Cormode D.P., Roessl E., Thran A., Skajaa T., Gordon R.E., Schlomka J.P., et al. Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles. Radiology 2010, 256(3):774-782.
    • (2010) Radiology , vol.256 , Issue.3 , pp. 774-782
    • Cormode, D.P.1    Roessl, E.2    Thran, A.3    Skajaa, T.4    Gordon, R.E.5    Schlomka, J.P.6
  • 68
    • 0345688224 scopus 로고    scopus 로고
    • Fundamental image quality limits for microcomputed tomography in small animals
    • Ford N.L., Thornton M.M., Holdsworth D.W. Fundamental image quality limits for microcomputed tomography in small animals. Med Phys 2003, 30:2869-2877.
    • (2003) Med Phys , vol.30 , pp. 2869-2877
    • Ford, N.L.1    Thornton, M.M.2    Holdsworth, D.W.3
  • 69
    • 9144260651 scopus 로고    scopus 로고
    • Small-animal X-ray dose from micro-CT
    • Boone J.M., Velazquez O., Cherry S.R. Small-animal X-ray dose from micro-CT. Mol Imaging 2004, 3(3):149-158.
    • (2004) Mol Imaging , vol.3 , Issue.3 , pp. 149-158
    • Boone, J.M.1    Velazquez, O.2    Cherry, S.R.3
  • 70
    • 31044442530 scopus 로고    scopus 로고
    • Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
    • Taschereau R., Chow P.L., Chatziioannou A.F. Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom. Med Phys 2006, 33(1):216-224.
    • (2006) Med Phys , vol.33 , Issue.1 , pp. 216-224
    • Taschereau, R.1    Chow, P.L.2    Chatziioannou, A.F.3
  • 72
    • 51849167033 scopus 로고
    • The influence of strain on acute x-ray lethality in the mouse. II. Recovery rate studies
    • Kohn H.I., Kallman R.F. The influence of strain on acute x-ray lethality in the mouse. II. Recovery rate studies. Radiat Res 1957, 6(3):329-338.
    • (1957) Radiat Res , vol.6 , Issue.3 , pp. 329-338
    • Kohn, H.I.1    Kallman, R.F.2
  • 74
    • 0000638624 scopus 로고
    • Vertebrate radiobiology (lethal actions and associated effects)
    • Bond V.P., Robertson J.S. Vertebrate radiobiology (lethal actions and associated effects). Annu Rev Nucl Sci 1957, 7:135-162.
    • (1957) Annu Rev Nucl Sci , vol.7 , pp. 135-162
    • Bond, V.P.1    Robertson, J.S.2
  • 75
    • 33646613562 scopus 로고
    • Quantitative observations on recovery from whole body irradiation in mice. II. Recovery during and after daily irradiation
    • Mole R.H. Quantitative observations on recovery from whole body irradiation in mice. II. Recovery during and after daily irradiation. Br J Radiol 1957, 30(349):40-46.
    • (1957) Br J Radiol , vol.30 , Issue.349 , pp. 40-46
    • Mole, R.H.1
  • 76
    • 33847411919 scopus 로고    scopus 로고
    • Small animal absorbed radiation dose from serial micro-computed tomography imaging
    • Carlson S.K., Classic K.L., Bender C.E., Russell S.J. Small animal absorbed radiation dose from serial micro-computed tomography imaging. Mol Imaging Biol 2007, 9(2):78-82.
    • (2007) Mol Imaging Biol , vol.9 , Issue.2 , pp. 78-82
    • Carlson, S.K.1    Classic, K.L.2    Bender, C.E.3    Russell, S.J.4
  • 77
    • 0021995104 scopus 로고
    • Dose rate dependence of response of mouse lung to irradiation
    • Lehnert S., Rybka W.B. Dose rate dependence of response of mouse lung to irradiation. Br J Radiol 1985, 58(692):745-749.
    • (1985) Br J Radiol , vol.58 , Issue.692 , pp. 745-749
    • Lehnert, S.1    Rybka, W.B.2
  • 78
    • 0021917207 scopus 로고
    • Repair in mouse lung for up to 20 fractions of X rays or neutrons
    • Parkins C.S., Fowler J.F., Maughan R.L., Roper M.J. Repair in mouse lung for up to 20 fractions of X rays or neutrons. Br J Radiol 1985, 58(687):225-241.
    • (1985) Br J Radiol , vol.58 , Issue.687 , pp. 225-241
    • Parkins, C.S.1    Fowler, J.F.2    Maughan, R.L.3    Roper, M.J.4
  • 79
    • 84880688083 scopus 로고    scopus 로고
    • X-ray dose delivered during a longitudinal micro-CT study has no adverse effect on cardiac and pulmonary tissue in C57BL/6 mice
    • Detombe S.A., Dunmore-Buyze J., Petrov I.E., Drangova M. X-ray dose delivered during a longitudinal micro-CT study has no adverse effect on cardiac and pulmonary tissue in C57BL/6 mice. Acta Radiologica 2013, 54(4):435-441.
    • (2013) Acta Radiologica , vol.54 , Issue.4 , pp. 435-441
    • Detombe, S.A.1    Dunmore-Buyze, J.2    Petrov, I.E.3    Drangova, M.4
  • 80
    • 0028910321 scopus 로고
    • In vivo, three-dimensional microscopy of trabecular bone
    • Kinney J.H., Lane N.E., Haupt D.L. In vivo, three-dimensional microscopy of trabecular bone. J Bone Miner Res 1995, 10(2):264-270.
    • (1995) J Bone Miner Res , vol.10 , Issue.2 , pp. 264-270
    • Kinney, J.H.1    Lane, N.E.2    Haupt, D.L.3
  • 81
    • 0030071062 scopus 로고    scopus 로고
    • A microtomographic system for the nondestructive evaluation of bone architecture
    • Ruegsegger P., Koller B., Muller R. A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 1996, 58(1):24-29.
    • (1996) Calcif Tissue Int , vol.58 , Issue.1 , pp. 24-29
    • Ruegsegger, P.1    Koller, B.2    Muller, R.3
  • 82
    • 33748288353 scopus 로고    scopus 로고
    • Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads
    • Chappard C., Basillais A., Benhamou L., Bonassie A., Brunet-Imbault B., Bonnet N., et al. Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Med Phys 2006, 33(9):3568-3577.
    • (2006) Med Phys , vol.33 , Issue.9 , pp. 3568-3577
    • Chappard, C.1    Basillais, A.2    Benhamou, L.3    Bonassie, A.4    Brunet-Imbault, B.5    Bonnet, N.6
  • 83
    • 33847373688 scopus 로고    scopus 로고
    • Forced mobilization accelerates pathogenesis: characterization of a preclinical surgical model of osteoarthritis
    • Appleton C.T., McErlain D.D., Pitelka V., Schwartz N., Bernier S.M., Henry J.L., et al. Forced mobilization accelerates pathogenesis: characterization of a preclinical surgical model of osteoarthritis. Arthritis Res Ther 2007, 9(1):R13.
    • (2007) Arthritis Res Ther , vol.9 , Issue.1
    • Appleton, C.T.1    McErlain, D.D.2    Pitelka, V.3    Schwartz, N.4    Bernier, S.M.5    Henry, J.L.6
  • 84
    • 41149086934 scopus 로고    scopus 로고
    • Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography
    • McErlain D.D., Appleton C.T., Litchfield R.B., Pitelka V., Henry J.L., Bernier S.M., et al. Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography. Osteoarthr Cartil 2008, 16(4):458-469.
    • (2008) Osteoarthr Cartil , vol.16 , Issue.4 , pp. 458-469
    • McErlain, D.D.1    Appleton, C.T.2    Litchfield, R.B.3    Pitelka, V.4    Henry, J.L.5    Bernier, S.M.6
  • 85
    • 34147201090 scopus 로고    scopus 로고
    • MicroCT evaluation of three-dimensional mineralization in response to BMP-2 doses in vitro and in critical sized rat calvarial defects
    • Cowan C.M., Aghaloo T., Chou Y.F., Walder B., Zhang X., Soo C., et al. MicroCT evaluation of three-dimensional mineralization in response to BMP-2 doses in vitro and in critical sized rat calvarial defects. Tissue Eng 2007, 13(3):501-512.
    • (2007) Tissue Eng , vol.13 , Issue.3 , pp. 501-512
    • Cowan, C.M.1    Aghaloo, T.2    Chou, Y.F.3    Walder, B.4    Zhang, X.5    Soo, C.6
  • 87
    • 0041977180 scopus 로고    scopus 로고
    • Noninvasive in vivo monitoring of bone architecture alterations in hindlimb-unloaded female rats using novel three-dimensional microcomputed tomography
    • David V., Laroche N., Boudignon B., Lafage-Proust M.H., Alexandre C., Ruegsegger P., et al. Noninvasive in vivo monitoring of bone architecture alterations in hindlimb-unloaded female rats using novel three-dimensional microcomputed tomography. J Bone Miner Res 2003, 18(9):1622-1631.
    • (2003) J Bone Miner Res , vol.18 , Issue.9 , pp. 1622-1631
    • David, V.1    Laroche, N.2    Boudignon, B.3    Lafage-Proust, M.H.4    Alexandre, C.5    Ruegsegger, P.6
  • 90
    • 62249191413 scopus 로고    scopus 로고
    • Stem cell-mediated accelerated bone healing observed with in vivo molecular and small animal imaging technologies in a model of skeletal injury
    • Lee S.W., Padmanabhan P., Ray P., Gambhir S.S., Doyle T., Contag C., et al. Stem cell-mediated accelerated bone healing observed with in vivo molecular and small animal imaging technologies in a model of skeletal injury. J Orthop Res 2009, 27(3):295-302.
    • (2009) J Orthop Res , vol.27 , Issue.3 , pp. 295-302
    • Lee, S.W.1    Padmanabhan, P.2    Ray, P.3    Gambhir, S.S.4    Doyle, T.5    Contag, C.6
  • 91
    • 60349093737 scopus 로고    scopus 로고
    • Bone mass and microarchitecture of irradiated and bone marrow-transplanted mice: influences of the donor strain
    • Dumas A., Brigitte M., Moreau M.F., Chrétien F., Baslé M.F., Chappard D. Bone mass and microarchitecture of irradiated and bone marrow-transplanted mice: influences of the donor strain. Osteoporos Int 2009, 20(3):435-443.
    • (2009) Osteoporos Int , vol.20 , Issue.3 , pp. 435-443
    • Dumas, A.1    Brigitte, M.2    Moreau, M.F.3    Chrétien, F.4    Baslé, M.F.5    Chappard, D.6
  • 92
    • 0035658186 scopus 로고    scopus 로고
    • The temporal changes of trabecular architecture in ovariectomized rats assessed by microCT
    • Laib A., Kumer J.L., Majumdar S., Lane N.E. The temporal changes of trabecular architecture in ovariectomized rats assessed by microCT. Osteoporos Int 2001, 12(11):936-941.
    • (2001) Osteoporos Int , vol.12 , Issue.11 , pp. 936-941
    • Laib, A.1    Kumer, J.L.2    Majumdar, S.3    Lane, N.E.4
  • 93
    • 0034094978 scopus 로고    scopus 로고
    • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis
    • Laib A., Barou O., Vico L., Lafage-Proust M.H., Alexandre C., Rugsegger P. 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis. Med Biol Eng Comput 2000, 38(3):326-332.
    • (2000) Med Biol Eng Comput , vol.38 , Issue.3 , pp. 326-332
    • Laib, A.1    Barou, O.2    Vico, L.3    Lafage-Proust, M.H.4    Alexandre, C.5    Rugsegger, P.6
  • 94
    • 0034812187 scopus 로고    scopus 로고
    • Effects of daily treatment with parathyroid hormone on bone microarchitecture and turnover in patients with osteoporosis: a paired biopsy study
    • Dempster D.W., Cosman F., Kurland E.S., Zhou H., Nieves J., Woelfert L., et al. Effects of daily treatment with parathyroid hormone on bone microarchitecture and turnover in patients with osteoporosis: a paired biopsy study. J Bone Miner Res 2001, 16(10):1846-1853.
    • (2001) J Bone Miner Res , vol.16 , Issue.10 , pp. 1846-1853
    • Dempster, D.W.1    Cosman, F.2    Kurland, E.S.3    Zhou, H.4    Nieves, J.5    Woelfert, L.6
  • 96
    • 27644595283 scopus 로고    scopus 로고
    • Functional bone engineering using ex vivo gene therapy and topology-optimized, biodegradable polymer composite scaffolds
    • Lin C.Y., Schek R.M., Mistry A.S., Shi X., Mikos A.G., Krebsbach P.H., et al. Functional bone engineering using ex vivo gene therapy and topology-optimized, biodegradable polymer composite scaffolds. Tissue Eng 2005, 11(9-10):1589-1598.
    • (2005) Tissue Eng , vol.11 , Issue.9-10 , pp. 1589-1598
    • Lin, C.Y.1    Schek, R.M.2    Mistry, A.S.3    Shi, X.4    Mikos, A.G.5    Krebsbach, P.H.6
  • 97
    • 28444460178 scopus 로고    scopus 로고
    • A comparison of micro CT with other techniques used in the characterization of scaffolds
    • Ho S.T., Hutmacher D.W. A comparison of micro CT with other techniques used in the characterization of scaffolds. Biomaterials 2006, 27(8):1362-1376.
    • (2006) Biomaterials , vol.27 , Issue.8 , pp. 1362-1376
    • Ho, S.T.1    Hutmacher, D.W.2
  • 98
    • 0035870103 scopus 로고    scopus 로고
    • Three-dimensional microimaging (MRμI and μCT), finite element modeling, and rapid prototyping provide unique insights into bone architecture in osteoporosis
    • Borah B., Gross G.J., Dufresne T.E., Smith T.S., Cockman M.D., Chmielewski P.A., et al. Three-dimensional microimaging (MRμI and μCT), finite element modeling, and rapid prototyping provide unique insights into bone architecture in osteoporosis. Anat Rec 2001, 265(2):101-110.
    • (2001) Anat Rec , vol.265 , Issue.2 , pp. 101-110
    • Borah, B.1    Gross, G.J.2    Dufresne, T.E.3    Smith, T.S.4    Cockman, M.D.5    Chmielewski, P.A.6
  • 101
    • 34948833684 scopus 로고    scopus 로고
    • Flat-panel detector-based volume computed tomography: a novel 3D imaging technique to monitor osteolytic bone lesions in a mouse tumor metastasis model
    • Missbach-Guentner J., Dullin C., Zientkowska M., Domeyer-Missbach M., Kimmina S., Obenauer S., et al. Flat-panel detector-based volume computed tomography: a novel 3D imaging technique to monitor osteolytic bone lesions in a mouse tumor metastasis model. Neoplasia 2007, 9(9):755-765.
    • (2007) Neoplasia , vol.9 , Issue.9 , pp. 755-765
    • Missbach-Guentner, J.1    Dullin, C.2    Zientkowska, M.3    Domeyer-Missbach, M.4    Kimmina, S.5    Obenauer, S.6
  • 102
    • 0345015502 scopus 로고    scopus 로고
    • Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro CT
    • Martin-Badosa E., Amblard D., Nuzzo S., Elmoutaouakkil A., Vico L., Peyrin F. Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro CT. Radiology 2003, 229(3):921-928.
    • (2003) Radiology , vol.229 , Issue.3 , pp. 921-928
    • Martin-Badosa, E.1    Amblard, D.2    Nuzzo, S.3    Elmoutaouakkil, A.4    Vico, L.5    Peyrin, F.6
  • 103
    • 0033105205 scopus 로고    scopus 로고
    • Accuracy of cancellous bone volume fraction measured by micro-CT scanning
    • Ding M., Odgaard A., Hvid I. Accuracy of cancellous bone volume fraction measured by micro-CT scanning. J Biomechanics 1999, 32(3):323-326.
    • (1999) J Biomechanics , vol.32 , Issue.3 , pp. 323-326
    • Ding, M.1    Odgaard, A.2    Hvid, I.3
  • 104
    • 34548535885 scopus 로고    scopus 로고
    • Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis
    • Buie H.R., Campbell G.M., Klinck R.J., MacNeil J.A., Boyd S.K. Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone 2007, 41(4):505-515.
    • (2007) Bone , vol.41 , Issue.4 , pp. 505-515
    • Buie, H.R.1    Campbell, G.M.2    Klinck, R.J.3    MacNeil, J.A.4    Boyd, S.K.5
  • 105
    • 84884413806 scopus 로고    scopus 로고
    • Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture
    • Buie H.R., Bosma N.A., Downey C.M., Jirik F.R., Boyd S.K. Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture. Med Eng Phys 2013, 35(11):1645-1650.
    • (2013) Med Eng Phys , vol.35 , Issue.11 , pp. 1645-1650
    • Buie, H.R.1    Bosma, N.A.2    Downey, C.M.3    Jirik, F.R.4    Boyd, S.K.5
  • 106
    • 31144434642 scopus 로고    scopus 로고
    • Micro-computed tomography of the lungs and pulmonary-vascular system
    • 501
    • Ritman E.L. Micro-computed tomography of the lungs and pulmonary-vascular system. Proc Am Thorac Soc 2005, 2(6):477-480. 501.
    • (2005) Proc Am Thorac Soc , vol.2 , Issue.6 , pp. 477-480
    • Ritman, E.L.1
  • 107
    • 27944437472 scopus 로고    scopus 로고
    • In vivo assessment of emphysema in mice by high resolution X-ray microtomography
    • Postnov A.A., Meurrens K., Weiler H., Van Dyck D., Xu H., Terpstra P., et al. In vivo assessment of emphysema in mice by high resolution X-ray microtomography. J Microsc 2005, 220(Pt 1):70-75.
    • (2005) J Microsc , vol.220 , Issue.PART 1 , pp. 70-75
    • Postnov, A.A.1    Meurrens, K.2    Weiler, H.3    Van Dyck, D.4    Xu, H.5    Terpstra, P.6
  • 108
    • 34250159800 scopus 로고    scopus 로고
    • A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice
    • Shofer S., Badea C., Auerbach S., Schwartz D.A., Johnson G.A. A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice. Exp Lung Res 2007, 33(3-4):169-183.
    • (2007) Exp Lung Res , vol.33 , Issue.3-4 , pp. 169-183
    • Shofer, S.1    Badea, C.2    Auerbach, S.3    Schwartz, D.A.4    Johnson, G.A.5
  • 109
    • 33144485766 scopus 로고    scopus 로고
    • Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures
    • Guerrero T., Castillo R., Sanders K., Price R., Komaki R., Cody D. Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures. Phys Med Biol 2006, 51(5):1101-1112.
    • (2006) Phys Med Biol , vol.51 , Issue.5 , pp. 1101-1112
    • Guerrero, T.1    Castillo, R.2    Sanders, K.3    Price, R.4    Komaki, R.5    Cody, D.6
  • 110
  • 111
    • 84866701632 scopus 로고    scopus 로고
    • Detection and early phase assessment of radiation-induced lung injury in mice using micro-CT
    • Saito S., Murase K. Detection and early phase assessment of radiation-induced lung injury in mice using micro-CT. PLoS One 2012, 7(9):e45960.
    • (2012) PLoS One , vol.7 , Issue.9
    • Saito, S.1    Murase, K.2
  • 112
    • 35648947301 scopus 로고    scopus 로고
    • Micro-CT imaging of rat lung ventilation using continuous image acquisition during xenon gas contrast enhancement
    • Lam W.W., Holdsworth D.W., Du L.Y., Drangova M., McCormack D.G., Santyr G.E. Micro-CT imaging of rat lung ventilation using continuous image acquisition during xenon gas contrast enhancement. J Appl Physiol 2007, 103(5):1848-1856.
    • (2007) J Appl Physiol , vol.103 , Issue.5 , pp. 1848-1856
    • Lam, W.W.1    Holdsworth, D.W.2    Du, L.Y.3    Drangova, M.4    McCormack, D.G.5    Santyr, G.E.6
  • 114
    • 77953648269 scopus 로고    scopus 로고
    • Rapid 3D phenotyping of cardiovascular development in mouse embryos by micro-CT with iodine staining
    • Degenhardt K., Wright A.C., Horng D., Padmanabhan A., Epstein J.A. Rapid 3D phenotyping of cardiovascular development in mouse embryos by micro-CT with iodine staining. Circ Cardiovasc Imaging 2010, 3(3):314-322.
    • (2010) Circ Cardiovasc Imaging , vol.3 , Issue.3 , pp. 314-322
    • Degenhardt, K.1    Wright, A.C.2    Horng, D.3    Padmanabhan, A.4    Epstein, J.A.5
  • 115
    • 34848869954 scopus 로고    scopus 로고
    • Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice
    • Badea C.T., Hedlund L.W., Mackel J.F., Mao L., Rockman H.A., Johnson G.A. Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice. Mol Imaging 2007, 6(4):261-268.
    • (2007) Mol Imaging , vol.6 , Issue.4 , pp. 261-268
    • Badea, C.T.1    Hedlund, L.W.2    Mackel, J.F.3    Mao, L.4    Rockman, H.A.5    Johnson, G.A.6
  • 117
    • 39249084014 scopus 로고    scopus 로고
    • Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent
    • Badea C.T., Wetzel A.W., Mistry N., Pomerantz S., Nave D., Johnson G.A. Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent. Comput Med Imaging Graph 2008, 32(3):239-250.
    • (2008) Comput Med Imaging Graph , vol.32 , Issue.3 , pp. 239-250
    • Badea, C.T.1    Wetzel, A.W.2    Mistry, N.3    Pomerantz, S.4    Nave, D.5    Johnson, G.A.6
  • 118
    • 50949124274 scopus 로고    scopus 로고
    • Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography
    • Detombe S.A., Ford N.L., Xiang F., Lu X., Feng Q., Drangova M. Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography. Investig Radiol 2008, 43(7):520-529.
    • (2008) Investig Radiol , vol.43 , Issue.7 , pp. 520-529
    • Detombe, S.A.1    Ford, N.L.2    Xiang, F.3    Lu, X.4    Feng, Q.5    Drangova, M.6
  • 119
    • 84870943176 scopus 로고    scopus 로고
    • Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT
    • Sawall S., Kuntz J., Socher M., Knaup M., Hess A., Bartling S., et al. Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT. Medical Physics 2012, 39(12):7499-7506.
    • (2012) Medical Physics , vol.39 , Issue.12 , pp. 7499-7506
    • Sawall, S.1    Kuntz, J.2    Socher, M.3    Knaup, M.4    Hess, A.5    Bartling, S.6
  • 121
    • 84858711896 scopus 로고    scopus 로고
    • Evaluation of eXIA 160 cardiac-related enhancement in C57BL/6 and BALB/c mice using micro-CT
    • Detombe S.A., Dunmore-Buyze J., Drangova M. Evaluation of eXIA 160 cardiac-related enhancement in C57BL/6 and BALB/c mice using micro-CT. Contrast Media Mol Imaging 2012, 7(2):240-246.
    • (2012) Contrast Media Mol Imaging , vol.7 , Issue.2 , pp. 240-246
    • Detombe, S.A.1    Dunmore-Buyze, J.2    Drangova, M.3
  • 122
    • 33744930583 scopus 로고    scopus 로고
    • User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability
    • Yushkevich P.A., Piven J., Hazlett H.C., Smith R.G., Ho S., Gee J.C., et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 2006, 31(3):1116-1128.
    • (2006) Neuroimage , vol.31 , Issue.3 , pp. 1116-1128
    • Yushkevich, P.A.1    Piven, J.2    Hazlett, H.C.3    Smith, R.G.4    Ho, S.5    Gee, J.C.6
  • 123
    • 0034345496 scopus 로고    scopus 로고
    • Computer vision, pattern recognition and image processing in left ventricle segmentation: the last 50 years
    • Suri J.S. Computer vision, pattern recognition and image processing in left ventricle segmentation: the last 50 years. Pattern Analysis Appl 2000, 3(3):209-242.
    • (2000) Pattern Analysis Appl , vol.3 , Issue.3 , pp. 209-242
    • Suri, J.S.1
  • 124
    • 0034744995 scopus 로고    scopus 로고
    • Three-dimensional modeling for functional analysis of cardiac images: a review
    • Frangi A.F., Niessen W.J., Viergever M.A. Three-dimensional modeling for functional analysis of cardiac images: a review. IEEE Trans Med Imaging 2001, 20(1):2-25.
    • (2001) IEEE Trans Med Imaging , vol.20 , Issue.1 , pp. 2-25
    • Frangi, A.F.1    Niessen, W.J.2    Viergever, M.A.3
  • 125
    • 84878344042 scopus 로고    scopus 로고
    • Constructing a 4D murine cardiac micro-CT atlas for automated segmentation and phenotyping applications
    • p. 86691P-86691P-12
    • Clark D., Badea A., Johnson G.A., Badea C.T. Constructing a 4D murine cardiac micro-CT atlas for automated segmentation and phenotyping applications. Proc SPIE 2013, 8669. p. 86691P-86691P-12.
    • (2013) Proc SPIE , vol.8669
    • Clark, D.1    Badea, A.2    Johnson, G.A.3    Badea, C.T.4
  • 128
    • 79956076132 scopus 로고    scopus 로고
    • 4D micro-CT for cardiac and perfusion applications with view under sampling
    • Badea C.T., Johnston S.M., Qi Y., Johnson G.A. 4D micro-CT for cardiac and perfusion applications with view under sampling. Phys Med Biol 2011, 56(11):3351-3369.
    • (2011) Phys Med Biol , vol.56 , Issue.11 , pp. 3351-3369
    • Badea, C.T.1    Johnston, S.M.2    Qi, Y.3    Johnson, G.A.4
  • 129
    • 84857845181 scopus 로고    scopus 로고
    • Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice
    • Armitage S.E.J., Pollmann S.I., Detombe S.A., Drangova M. Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice. Med Phys 2012, 39(3):1452-1461.
    • (2012) Med Phys , vol.39 , Issue.3 , pp. 1452-1461
    • Armitage, S.E.J.1    Pollmann, S.I.2    Detombe, S.A.3    Drangova, M.4
  • 130
    • 84864655643 scopus 로고    scopus 로고
    • Temporal and spectral imaging with micro-CT
    • Johnston S.M., Johnson G.A., Badea C.T. Temporal and spectral imaging with micro-CT. Med Phys 2012, 39(8):4943-4958.
    • (2012) Med Phys , vol.39 , Issue.8 , pp. 4943-4958
    • Johnston, S.M.1    Johnson, G.A.2    Badea, C.T.3
  • 131
    • 17644420307 scopus 로고    scopus 로고
    • Murine lung tumor measurement using respiratory-gated micro-computed tomography
    • Cody D.D., Nelson C.L., Bradley W.M., Wislez M., Juroske D., Price R.E., et al. Murine lung tumor measurement using respiratory-gated micro-computed tomography. Invest Radiol 2005, 40(5):263-269.
    • (2005) Invest Radiol , vol.40 , Issue.5 , pp. 263-269
    • Cody, D.D.1    Nelson, C.L.2    Bradley, W.M.3    Wislez, M.4    Juroske, D.5    Price, R.E.6
  • 132
    • 25144450545 scopus 로고    scopus 로고
    • Functional CT for quantifying tumor perfusion in antiangiogenic therapy in a rat model
    • Kan Z., Phongkitkarun S., Kobayashi S., Tang Y., Ellis L.M., Lee T.Y., et al. Functional CT for quantifying tumor perfusion in antiangiogenic therapy in a rat model. Radiology 2005, 237(1):151-158.
    • (2005) Radiology , vol.237 , Issue.1 , pp. 151-158
    • Kan, Z.1    Phongkitkarun, S.2    Kobayashi, S.3    Tang, Y.4    Ellis, L.M.5    Lee, T.Y.6
  • 133
    • 2042533502 scopus 로고    scopus 로고
    • Quantification of angiogenesis by functional computed tomography in a Matrigel model in rats
    • Phongkitkarun S., Kobayashi S., Kan Z., Lee T.Y., Charnsangavej C. Quantification of angiogenesis by functional computed tomography in a Matrigel model in rats. Acad Radiol 2004, 11(5):573-582.
    • (2004) Acad Radiol , vol.11 , Issue.5 , pp. 573-582
    • Phongkitkarun, S.1    Kobayashi, S.2    Kan, Z.3    Lee, T.Y.4    Charnsangavej, C.5
  • 134
    • 36348998124 scopus 로고    scopus 로고
    • A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
    • Du L.Y., Umoh J., Nikolov H.N., Pollmann S.I., Lee T.Y., Holdsworth D.W. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol 2007, 52(23):7087-7108.
    • (2007) Phys Med Biol , vol.52 , Issue.23 , pp. 7087-7108
    • Du, L.Y.1    Umoh, J.2    Nikolov, H.N.3    Pollmann, S.I.4    Lee, T.Y.5    Holdsworth, D.W.6
  • 135
    • 31344473376 scopus 로고    scopus 로고
    • Practical vessel imaging by computed tomography in live transgenic mouse models for human tumors
    • Kindlmann G.L., Weinstein D.M., Jones G.M., Johnson C.R., Capecchi M.R., Keller C. Practical vessel imaging by computed tomography in live transgenic mouse models for human tumors. Mol Imaging 2005, 4(4):417-424.
    • (2005) Mol Imaging , vol.4 , Issue.4 , pp. 417-424
    • Kindlmann, G.L.1    Weinstein, D.M.2    Jones, G.M.3    Johnson, C.R.4    Capecchi, M.R.5    Keller, C.6
  • 136
    • 34249870120 scopus 로고    scopus 로고
    • In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice
    • Almajdub M., Nejjari M., Poncet G., Magnier L., Chereul E., Roche C., et al. In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice. Contrast Media Mol Imaging 2007, 2(2):88-93.
    • (2007) Contrast Media Mol Imaging , vol.2 , Issue.2 , pp. 88-93
    • Almajdub, M.1    Nejjari, M.2    Poncet, G.3    Magnier, L.4    Chereul, E.5    Roche, C.6
  • 137
    • 39549106895 scopus 로고    scopus 로고
    • MicroCT liver contrast agent enhancement over time, dose, and mouse strain
    • Suckow C.E., Stout D.B. MicroCT liver contrast agent enhancement over time, dose, and mouse strain. Mol Imaging Biol 2008, 10(2):114-120.
    • (2008) Mol Imaging Biol , vol.10 , Issue.2 , pp. 114-120
    • Suckow, C.E.1    Stout, D.B.2
  • 138
    • 38149061404 scopus 로고    scopus 로고
    • Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography
    • Graham K.C., Ford N.L., MacKenzie L.T., Postenka C.O., Groom A.C., MacDonald I.C., et al. Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography. Invest Radiol 2008, 43(2):92-99.
    • (2008) Invest Radiol , vol.43 , Issue.2 , pp. 92-99
    • Graham, K.C.1    Ford, N.L.2    MacKenzie, L.T.3    Postenka, C.O.4    Groom, A.C.5    MacDonald, I.C.6
  • 139
    • 80053579564 scopus 로고    scopus 로고
    • Micro-CT based experimental liver imaging using a nanoparticulate contrast agent: a longitudinal study in mice
    • Boll H., Nittka S., Doyon F., Neumaier M., Marx A., Kramer M., et al. Micro-CT based experimental liver imaging using a nanoparticulate contrast agent: a longitudinal study in mice. Plos One 2011, 6(9).
    • (2011) Plos One , vol.6 , Issue.9
    • Boll, H.1    Nittka, S.2    Doyon, F.3    Neumaier, M.4    Marx, A.5    Kramer, M.6
  • 140
    • 78649944912 scopus 로고    scopus 로고
    • Evaluation of tumor microenvironment in an animal model using a nanoparticle contrast agent in computed tomography imaging
    • Ghaghada K.B., Badea C.T., Karumbaiah L., Fettig N., Bellamkonda R.V., Johnson G.A., et al. Evaluation of tumor microenvironment in an animal model using a nanoparticle contrast agent in computed tomography imaging. Acad Radiol 2011, 18(1):20-30.
    • (2011) Acad Radiol , vol.18 , Issue.1 , pp. 20-30
    • Ghaghada, K.B.1    Badea, C.T.2    Karumbaiah, L.3    Fettig, N.4    Bellamkonda, R.V.5    Johnson, G.A.6
  • 141
    • 84875255790 scopus 로고    scopus 로고
    • Dual-energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas
    • Moding E.J., Clark D.P., Qi Y., Li Y., Ma Y., Ghaghada K., et al. Dual-energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas. Int J Radiat Oncol Biol Phys 2013, 85(5):1353-1359.
    • (2013) Int J Radiat Oncol Biol Phys , vol.85 , Issue.5 , pp. 1353-1359
    • Moding, E.J.1    Clark, D.P.2    Qi, Y.3    Li, Y.4    Ma, Y.5    Ghaghada, K.6
  • 142
    • 0034993240 scopus 로고    scopus 로고
    • The enhanced permeability and retention (EPR) effect in tumor vasculature: the key role of tumor-selective macromolecular drug targeting
    • Maeda H. The enhanced permeability and retention (EPR) effect in tumor vasculature: the key role of tumor-selective macromolecular drug targeting. Adv Enzyme Regul 2001, 41:189-207.
    • (2001) Adv Enzyme Regul , vol.41 , pp. 189-207
    • Maeda, H.1
  • 143
    • 84859378482 scopus 로고    scopus 로고
    • Computed tomography imaging of primary lung cancer in mice using a liposomal-iodinated contrast agent
    • Badea C.T., Athreya K.K., Espinosa G., Clark D., Ghafoori A.P., Li Y., et al. Computed tomography imaging of primary lung cancer in mice using a liposomal-iodinated contrast agent. PLoS ONE 2012, 7(4):e34496.
    • (2012) PLoS ONE , vol.7 , Issue.4
    • Badea, C.T.1    Athreya, K.K.2    Espinosa, G.3    Clark, D.4    Ghafoori, A.P.5    Li, Y.6
  • 144
    • 65449156044 scopus 로고    scopus 로고
    • A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging
    • Kepshire D., Mincu N., Hutchins M., Gruber J., Dehghani H., Hypnarowski J., et al. A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging. Rev Sci Instrum 2009, 80(4):043701.
    • (2009) Rev Sci Instrum , vol.80 , Issue.4 , pp. 043701
    • Kepshire, D.1    Mincu, N.2    Hutchins, M.3    Gruber, J.4    Dehghani, H.5    Hypnarowski, J.6
  • 145
    • 0037153878 scopus 로고    scopus 로고
    • Simultaneous molecular and anatomical imaging of the mouse in vivo
    • Goertzen A.L., Meadors A.K., Silverman R.W., Cherry S.R. Simultaneous molecular and anatomical imaging of the mouse in vivo. Phys Med Biol 2002, 47(24):4315-4328.
    • (2002) Phys Med Biol , vol.47 , Issue.24 , pp. 4315-4328
    • Goertzen, A.L.1    Meadors, A.K.2    Silverman, R.W.3    Cherry, S.R.4
  • 147
  • 148
    • 23744491662 scopus 로고    scopus 로고
    • A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images
    • Jan M.L., Chuang K.S., Chen G.W., Ni Y.C., Chen S., Chang C.H., et al. A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images. IEEE Trans Med Imaging 2005, 24(7):886-893.
    • (2005) IEEE Trans Med Imaging , vol.24 , Issue.7 , pp. 886-893
    • Jan, M.L.1    Chuang, K.S.2    Chen, G.W.3    Ni, Y.C.4    Chen, S.5    Chang, C.H.6
  • 149
    • 22844452107 scopus 로고    scopus 로고
    • Attenuation correction for small animal PET tomographs
    • Chow P.L., Rannou F.R., Chatziioannou A.F. Attenuation correction for small animal PET tomographs. Phys Med Biol 2005, 50(8):1837-1850.
    • (2005) Phys Med Biol , vol.50 , Issue.8 , pp. 1837-1850
    • Chow, P.L.1    Rannou, F.R.2    Chatziioannou, A.F.3
  • 150
    • 0017452940 scopus 로고
    • A Method for attenuation correction in radionuclide computed tomography
    • Chang L.-T. A Method for attenuation correction in radionuclide computed tomography. Nucl Sci IEEE Trans 1978, 25(1):638-643.
    • (1978) Nucl Sci IEEE Trans , vol.25 , Issue.1 , pp. 638-643
    • Chang, L.-T.1
  • 151
    • 25644457673 scopus 로고    scopus 로고
    • Attenuation correction for small animal SPECT imaging using x-ray CT data
    • Hwang A.B., Hasegawa B.H. Attenuation correction for small animal SPECT imaging using x-ray CT data. Med Phys 2005, 32(9):2799-2804.
    • (2005) Med Phys , vol.32 , Issue.9 , pp. 2799-2804
    • Hwang, A.B.1    Hasegawa, B.H.2
  • 152
    • 67349083609 scopus 로고    scopus 로고
    • Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information
    • Vanhove C., Defrise M., Bossuyt A., Lahoutte T. Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information. Eur J Nucl Med Mol Imaging 2009, 36(7):1049-1063.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.7 , pp. 1049-1063
    • Vanhove, C.1    Defrise, M.2    Bossuyt, A.3    Lahoutte, T.4
  • 153
    • 23844518743 scopus 로고    scopus 로고
    • U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice
    • Beekman F.J., van der Have F., Vastenhouw B., van der Linden A.J., van Rijk P.P., Burbach J.P., et al. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice. J Nucl Med 2005, 46(7):1194-1200.
    • (2005) J Nucl Med , vol.46 , Issue.7 , pp. 1194-1200
    • Beekman, F.J.1    van der Have, F.2    Vastenhouw, B.3    van der Linden, A.J.4    van Rijk, P.P.5    Burbach, J.P.6
  • 154
    • 37649007920 scopus 로고    scopus 로고
    • Imaging of gene expression in live pancreatic islet cell lines using dual-isotope SPECT
    • Tai J.H., Nguyen B., Wells R.G., Kovacs M.S., McGirr R., Prato F.S., et al. Imaging of gene expression in live pancreatic islet cell lines using dual-isotope SPECT. J Nucl Med 2008, 49(1):94-102.
    • (2008) J Nucl Med , vol.49 , Issue.1 , pp. 94-102
    • Tai, J.H.1    Nguyen, B.2    Wells, R.G.3    Kovacs, M.S.4    McGirr, R.5    Prato, F.S.6
  • 155
    • 0036980761 scopus 로고    scopus 로고
    • Molecular imaging in small animals-roles for micro-CT
    • Ritman E.L. Molecular imaging in small animals-roles for micro-CT. J Cell Biochem Suppl 2002, 39:116-124.
    • (2002) J Cell Biochem Suppl , vol.39 , pp. 116-124
    • Ritman, E.L.1
  • 156
    • 84901785330 scopus 로고    scopus 로고
    • Dual-energy micro-CT imaging of pulmonary airway obstruction: correlation with micro-SPECT
    • p. 90380U-90380U-8
    • Badea C., Befera N., Clark D., Qi Y., Johnson G. Dual-energy micro-CT imaging of pulmonary airway obstruction: correlation with micro-SPECT. SPIE Med Imaging 2014, 9038. p. 90380U-90380U-8.
    • (2014) SPIE Med Imaging , vol.9038
    • Badea, C.1    Befera, N.2    Clark, D.3    Qi, Y.4    Johnson, G.5
  • 159
    • 84860358357 scopus 로고    scopus 로고
    • A comparison of sampling strategies for dual energy micro-CT
    • Guo X., Johnston S.M., Johnson G.A., Badea C.T. A comparison of sampling strategies for dual energy micro-CT. Proc SPIE 2012, 8313:831332.
    • (2012) Proc SPIE , vol.8313 , pp. 831332
    • Guo, X.1    Johnston, S.M.2    Johnson, G.A.3    Badea, C.T.4
  • 160
    • 84895758037 scopus 로고    scopus 로고
    • Dual-energy micro-ct functional imaging of primary lung cancer in mice using gold and iodine nanoparticle contrast agents: a validation study
    • Ashton J.R., Clark D.P., Moding E.J., Ghaghada K., Kirsch D.G., West J.L., et al. Dual-energy micro-ct functional imaging of primary lung cancer in mice using gold and iodine nanoparticle contrast agents: a validation study. PLoS One 2014, 9(2):e88129.
    • (2014) PLoS One , vol.9 , Issue.2
    • Ashton, J.R.1    Clark, D.P.2    Moding, E.J.3    Ghaghada, K.4    Kirsch, D.G.5    West, J.L.6
  • 161
    • 79955750041 scopus 로고    scopus 로고
    • Dual-energy micro-CT imaging for differentiation of iodine-and gold-based nanoparticles
    • Badea C., Johnston S., Qi Y., Ghaghada K., Johnson G. Dual-energy micro-CT imaging for differentiation of iodine-and gold-based nanoparticles. Proc SPIE 2011, 7961:79611X.
    • (2011) Proc SPIE , vol.7961
    • Badea, C.1    Johnston, S.2    Qi, Y.3    Ghaghada, K.4    Johnson, G.5
  • 163
    • 84893870063 scopus 로고    scopus 로고
    • Assessing cardiac injury in mice with dual energy-Microct, 4D-Microct, and MicroSPECT imaging after partial heart irradiation
    • Lee C.L., Min H., Befera N., Clark D., Qi Y., Das S., et al. Assessing cardiac injury in mice with dual energy-Microct, 4D-Microct, and MicroSPECT imaging after partial heart irradiation. Int J Radiat Oncol Biol Phys 2014, 88(3):686-693.
    • (2014) Int J Radiat Oncol Biol Phys , vol.88 , Issue.3 , pp. 686-693
    • Lee, C.L.1    Min, H.2    Befera, N.3    Clark, D.4    Qi, Y.5    Das, S.6
  • 164
    • 84875255790 scopus 로고    scopus 로고
    • Dual-Energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas
    • Moding E.J., Clark D.P., Qi Y., Li Y., Ma Y., Ghaghada K., et al. Dual-Energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas. Int J Radiat Oncol Biol Phys 2012.
    • (2012) Int J Radiat Oncol Biol Phys
    • Moding, E.J.1    Clark, D.P.2    Qi, Y.3    Li, Y.4    Ma, Y.5    Ghaghada, K.6
  • 165
    • 84874891245 scopus 로고    scopus 로고
    • In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT
    • Clark D.P., Ghaghada K., Moding E.J., Kirsch D.G., Badea C.T. In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT. Phys Med Biol 2013, 58(6):1683-1704.
    • (2013) Phys Med Biol , vol.58 , Issue.6 , pp. 1683-1704
    • Clark, D.P.1    Ghaghada, K.2    Moding, E.J.3    Kirsch, D.G.4    Badea, C.T.5
  • 166
    • 84877309415 scopus 로고    scopus 로고
    • Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent
    • Bhavane R., Badea C., Ghaghada K.B., Clark D., Vela D., Moturu A., et al. Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent. Circ Cardiovasc Imaging 2013, 6(2):285-294.
    • (2013) Circ Cardiovasc Imaging , vol.6 , Issue.2 , pp. 285-294
    • Bhavane, R.1    Badea, C.2    Ghaghada, K.B.3    Clark, D.4    Vela, D.5    Moturu, A.6
  • 167
    • 54949084297 scopus 로고    scopus 로고
    • Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition
    • Granton P.V., Pollmann S.I., Ford N.L., Drangova M., Holdsworth D.W. Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition. Med Phys 2008, 35(11):5030-5042.
    • (2008) Med Phys , vol.35 , Issue.11 , pp. 5030-5042
    • Granton, P.V.1    Pollmann, S.I.2    Ford, N.L.3    Drangova, M.4    Holdsworth, D.W.5
  • 168
    • 48349103232 scopus 로고    scopus 로고
    • Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography
    • Schlomka J.P., Roessl E., Dorscheid R., Dill S., Martens G., Istel T., et al. Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. Phys Med Biol 2008, 53(15):4031-4047.
    • (2008) Phys Med Biol , vol.53 , Issue.15 , pp. 4031-4047
    • Schlomka, J.P.1    Roessl, E.2    Dorscheid, R.3    Dill, S.4    Martens, G.5    Istel, T.6
  • 172
    • 4644321604 scopus 로고    scopus 로고
    • The use of gold nanoparticles to enhance radiotherapy in mice
    • Hainfeld J.F., Slatkin D.N., Smilowitz H.M. The use of gold nanoparticles to enhance radiotherapy in mice. Phys Med Biol 2004, 49(18):N309-N315.
    • (2004) Phys Med Biol , vol.49 , Issue.18
    • Hainfeld, J.F.1    Slatkin, D.N.2    Smilowitz, H.M.3
  • 173
    • 84871206969 scopus 로고    scopus 로고
    • X-ray phase-contrast imaging: from pre-clinical applications towards clinics
    • Bravin A., Coan P., Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol 2013, 58(1):R1.
    • (2013) Phys Med Biol , vol.58 , Issue.1
    • Bravin, A.1    Coan, P.2    Suortti, P.3
  • 174
    • 52949126316 scopus 로고    scopus 로고
    • Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography
    • Langer M., Cloetens P., Guigay J.-P., Peyrin F. Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography. Med Phys 2008, 35(10):4556-4566.
    • (2008) Med Phys , vol.35 , Issue.10 , pp. 4556-4566
    • Langer, M.1    Cloetens, P.2    Guigay, J.-P.3    Peyrin, F.4
  • 177
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
    • Pfeiffer F., Weitkamp T., Bunk O., David C. Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources. Nat Phys 2006, 2(4):258-261.
    • (2006) Nat Phys , vol.2 , Issue.4 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 180
    • 84866846530 scopus 로고    scopus 로고
    • Experimental results from a preclinical X-ray phase-contrast CT scanner
    • Tapfer A., Bech M., Velroyen A., Meiser J., Mohr J., Walter M., et al. Experimental results from a preclinical X-ray phase-contrast CT scanner. Proc Natl Acad Sci 2012, 109(39):15691-15696.
    • (2012) Proc Natl Acad Sci , vol.109 , Issue.39 , pp. 15691-15696
    • Tapfer, A.1    Bech, M.2    Velroyen, A.3    Meiser, J.4    Mohr, J.5    Walter, M.6
  • 181
    • 84874867575 scopus 로고    scopus 로고
    • X-ray phase-contrast CT of a pancreatic ductal adenocarcinoma mouse model
    • Tapfer A., Braren R., Bech M., Willner M., Zanette I., Weitkamp T., et al. X-ray phase-contrast CT of a pancreatic ductal adenocarcinoma mouse model. PloS one 2013, 8(3):e58439.
    • (2013) PloS one , vol.8 , Issue.3
    • Tapfer, A.1    Braren, R.2    Bech, M.3    Willner, M.4    Zanette, I.5    Weitkamp, T.6
  • 182
    • 84896498861 scopus 로고    scopus 로고
    • Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging
    • Willner M., Herzen J., Grandl S., Auweter S., Mayr D., Hipp A., et al. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging. Phys Med Biology 2014, 59(7):1557.
    • (2014) Phys Med Biology , vol.59 , Issue.7 , pp. 1557
    • Willner, M.1    Herzen, J.2    Grandl, S.3    Auweter, S.4    Mayr, D.5    Hipp, A.6
  • 183
    • 84896093861 scopus 로고    scopus 로고
    • Lung tumors on multimodal radiographs derived from grating-based X-ray imaging - a feasibility study
    • Meinel F.G., Schwab F., Yaroshenko A., Velroyen A., Bech M., Hellbach K., et al. Lung tumors on multimodal radiographs derived from grating-based X-ray imaging - a feasibility study. Phys Med 2014, 30(3):352-357.
    • (2014) Phys Med , vol.30 , Issue.3 , pp. 352-357
    • Meinel, F.G.1    Schwab, F.2    Yaroshenko, A.3    Velroyen, A.4    Bech, M.5    Hellbach, K.6
  • 184
    • 84865564973 scopus 로고    scopus 로고
    • Phase and absorption retrieval using incoherent X-ray sources
    • Munro P.R., Ignatyev K., Speller R.D., Olivo A. Phase and absorption retrieval using incoherent X-ray sources. Proc Natl Acad Sci 2012, 109(35):13922-13927.
    • (2012) Proc Natl Acad Sci , vol.109 , Issue.35 , pp. 13922-13927
    • Munro, P.R.1    Ignatyev, K.2    Speller, R.D.3    Olivo, A.4
  • 185
    • 79957846831 scopus 로고    scopus 로고
    • Translation of synchrotron-based research into the clinic: assessing the current clinical potential of diffraction enhanced imaging
    • Connor D., Pisano E., Cole E., Zhong Z., Dilmanian F., Parham C., et al. Translation of synchrotron-based research into the clinic: assessing the current clinical potential of diffraction enhanced imaging. Synchrotron Radiat News 2011, 24(2):29-33.
    • (2011) Synchrotron Radiat News , vol.24 , Issue.2 , pp. 29-33
    • Connor, D.1    Pisano, E.2    Cole, E.3    Zhong, Z.4    Dilmanian, F.5    Parham, C.6
  • 186
    • 84896069067 scopus 로고    scopus 로고
    • Helical differential X-ray phase-contrast computed tomography
    • Fu J., Willner M., Chen L., Tan R., Achterhold K., Bech M., et al. Helical differential X-ray phase-contrast computed tomography. Phys Med 2014, 30(3):374-379.
    • (2014) Phys Med , vol.30 , Issue.3 , pp. 374-379
    • Fu, J.1    Willner, M.2    Chen, L.3    Tan, R.4    Achterhold, K.5    Bech, M.6
  • 187
    • 84855446783 scopus 로고    scopus 로고
    • Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping
    • Bevins N., Zambelli J., Li K., Qi Z., Chen G.-H. Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping. Med Phys 2011, 39(1):424-428.
    • (2011) Med Phys , vol.39 , Issue.1 , pp. 424-428
    • Bevins, N.1    Zambelli, J.2    Li, K.3    Qi, Z.4    Chen, G.-H.5
  • 188
    • 84890013077 scopus 로고    scopus 로고
    • Unwrapping differential x-ray phase-contrast images through phase estimation from multiple energy data
    • Epple F., Potdevin G., Thibault P., Ehn S., Herzen J., Hipp A., et al. Unwrapping differential x-ray phase-contrast images through phase estimation from multiple energy data. Opt Express 2013, 21(24):29101-29108.
    • (2013) Opt Express , vol.21 , Issue.24 , pp. 29101-29108
    • Epple, F.1    Potdevin, G.2    Thibault, P.3    Ehn, S.4    Herzen, J.5    Hipp, A.6
  • 189
    • 84878334247 scopus 로고    scopus 로고
    • High Energy X-ray Phase-Contrast Imaging Using Glancing Angle Grating Interferometers
    • p. 866814-1.
    • Stutman D., Stayman J., Finkenthal M., Siewerdsen J. High Energy X-ray Phase-Contrast Imaging Using Glancing Angle Grating Interferometers. Proc SPIE 2013, 8668. p. 866814-1.
    • (2013) Proc SPIE , vol.8668
    • Stutman, D.1    Stayman, J.2    Finkenthal, M.3    Siewerdsen, J.4
  • 190
    • 79961059565 scopus 로고    scopus 로고
    • Iterative reconstruction for differential phase contrast imaging using spherically symmetric basis functions
    • Köhler T., Brendel B., Roessl E. Iterative reconstruction for differential phase contrast imaging using spherically symmetric basis functions. Med Phys 2011, 38(8):4542-4545.
    • (2011) Med Phys , vol.38 , Issue.8 , pp. 4542-4545
    • Köhler, T.1    Brendel, B.2    Roessl, E.3
  • 191
    • 84881555022 scopus 로고    scopus 로고
    • An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography
    • Fu J., Schleede S., Tan R., Chen L., Bech M., Achterhold K., et al. An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography. Zeitschrift für Medizinische Physik 2013, 23(3):186-193.
    • (2013) Zeitschrift für Medizinische Physik , vol.23 , Issue.3 , pp. 186-193
    • Fu, J.1    Schleede, S.2    Tan, R.3    Chen, L.4    Bech, M.5    Achterhold, K.6
  • 192
    • 84898405799 scopus 로고    scopus 로고
    • Imaging liver lesions using grating-based phase-contrast computed tomography with bi-lateral filter post-processing
    • Herzen J., Willner M.S., Fingerle A.A., Noël P.B., Köhler T., Drecoll E., et al. Imaging liver lesions using grating-based phase-contrast computed tomography with bi-lateral filter post-processing. PloS one 2014, 9(1):e83369.
    • (2014) PloS one , vol.9 , Issue.1
    • Herzen, J.1    Willner, M.S.2    Fingerle, A.A.3    Noël, P.B.4    Köhler, T.5    Drecoll, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.