메뉴 건너뛰기




Volumn 55, Issue 3, 2008, Pages 1082-1091

A high-precision contrast injector for small animal X-ray digital subtraction angiography

Author keywords

Contrast agent; Digital subtraction angiography; Functional imaging; Rodent; X ray

Indexed keywords

BLOOD VESSELS; CONTRAST MEDIA; FUNCTIONAL ANALYSIS; X RAYS;

EID: 39749124359     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.909541     Document Type: Article
Times cited : (29)

References (39)
  • 1
    • 0033805467 scopus 로고    scopus 로고
    • X-ray videodensitometric methods for blood flow and velocity measurement: A critical review of literature
    • S. D. Shpilfoygel, R. A. Close, D. J. Valentino, and G. R. Duckwiler, "X-ray videodensitometric methods for blood flow and velocity measurement: A critical review of literature," Med. Phys., vol. 27, pp. 2008-2023, 2000.
    • (2000) Med. Phys , vol.27 , pp. 2008-2023
    • Shpilfoygel, S.D.1    Close, R.A.2    Valentino, D.J.3    Duckwiler, G.R.4
  • 2
    • 84901963622 scopus 로고
    • Systolic and diastolic global right and left ventricular function assessment in small animals using an automated angiographic technique
    • V. Bhargava, G. Hagan, M. I. Miyamoto, S. Ono, S. Ono, H. Rockman, and J. J. Ross, "Systolic and diastolic global right and left ventricular function assessment in small animals using an automated angiographic technique," in Proc. IEEE Comput. Cardiol., 1992, pp. 191-194.
    • (1992) Proc. IEEE Comput. Cardiol , pp. 191-194
    • Bhargava, V.1    Hagan, G.2    Miyamoto, M.I.3    Ono, S.4    Ono, S.5    Rockman, H.6    Ross, J.J.7
  • 3
    • 0020788420 scopus 로고
    • AUR memorial award. Determinants of contrast enhancement for intravenous digital subtraction angiography
    • F. H. Burbank, "AUR memorial award. Determinants of contrast enhancement for intravenous digital subtraction angiography," Invest. Radiol., vol. 18, pp. 308-316, 1983.
    • (1983) Invest. Radiol , vol.18 , pp. 308-316
    • Burbank, F.H.1
  • 4
    • 0019993273 scopus 로고
    • Quantitation of left ventricular dimensions and function by digital video subtraction angiography
    • C. B. Higgins, "Quantitation of left ventricular dimensions and function by digital video subtraction angiography," Diag. Radiol., vol. 144, pp. 461-469, 1982.
    • (1982) Diag. Radiol , vol.144 , pp. 461-469
    • Higgins, C.B.1
  • 5
    • 0020795043 scopus 로고
    • Digital subtraction angiography. Techniques and applications for evaluating cardiac anatomy and function
    • C. B. Higgins and E. Buonocore, "Digital subtraction angiography. Techniques and applications for evaluating cardiac anatomy and function," Cardiol. Clinics, vol. 1, pp. 413-425, 1983.
    • (1983) Cardiol. Clinics , vol.1 , pp. 413-425
    • Higgins, C.B.1    Buonocore, E.2
  • 6
    • 0031806753 scopus 로고    scopus 로고
    • Computational imaging of cerebral perfusion by real time processing of DSA images. Clinical applications
    • M. Hirata, Yoshimine, Toshiki, Kato, Amami, Ito, Mamoru, Hirabuki, T. Norio, Masaaki, Nakamura, Hironobu, Hayakawa, and Toru, "Computational imaging of cerebral perfusion by real time processing of DSA images. Clinical applications," Neuro Res., vol. 20, pp. 327-332, 1998.
    • (1998) Neuro Res , vol.20 , pp. 327-332
    • Hirata, M.1    Yoshimine, T.2    Kato, A.3    Ito, M.4    Hirabuki5    Norio, T.6    Masaaki, N.7    Hironobu, H.8    Toru9
  • 7
    • 0036241862 scopus 로고    scopus 로고
    • X-ray digital subtraction angiography with 1 mol/L gadobutrol: Results from a comparative porcine study with iodinated contrast agents
    • M. Kalinowski, O. Kress, T. Wels, H. Alfke, K. J. Klose, and H. J. Wagner, "X-ray digital subtraction angiography with 1 mol/L gadobutrol: Results from a comparative porcine study with iodinated contrast agents," Invest. Radiol., vol. 37, pp. 254-262, 2002.
    • (2002) Invest. Radiol , vol.37 , pp. 254-262
    • Kalinowski, M.1    Kress, O.2    Wels, T.3    Alfke, H.4    Klose, K.J.5    Wagner, H.J.6
  • 8
    • 0020569275 scopus 로고
    • Digital subtraction angiography of the pulmonary arteries for the diagnosis of pulmonary embolism
    • J. Ludwig, L. Verhoeven, J. Kersbergen, and T. Overtoom, "Digital subtraction angiography of the pulmonary arteries for the diagnosis of pulmonary embolism," Radiology, vol. 147, pp. 639-645, 1983.
    • (1983) Radiology , vol.147 , pp. 639-645
    • Ludwig, J.1    Verhoeven, L.2    Kersbergen, J.3    Overtoom, T.4
  • 9
    • 0019208734 scopus 로고
    • Digital subtraction angiography of the human cardiovascular system
    • T. Meaney, "Digital subtraction angiography of the human cardiovascular system," Amer. J. Roentgenol., vol. 135, pp. 1153-1160, 1980.
    • (1980) Amer. J. Roentgenol , vol.135 , pp. 1153-1160
    • Meaney, T.1
  • 10
    • 0021327484 scopus 로고
    • An experimental evaluation of central vs. peripheral injection for intravenous digital subtraction angiography (IV-DSA)
    • D. L. Rubin, F. H. Burbank, B. R. Bradley, and W. R. Brody, "An experimental evaluation of central vs. peripheral injection for intravenous digital subtraction angiography (IV-DSA)," Invest. Radiol., vol. 19, pp. 30-35, 1984.
    • (1984) Invest. Radiol , vol.19 , pp. 30-35
    • Rubin, D.L.1    Burbank, F.H.2    Bradley, B.R.3    Brody, W.R.4
  • 11
    • 0030671180 scopus 로고    scopus 로고
    • Digital subtraction versus film-screen angiography for detecting acute pulmonary emboli: Evaluation in a porcine model
    • F. J. Schlueter, D. A. Zuckerman, L. Horesh, F. R. Gutierrez, M. E. Hicks, and J. A. Brink, "Digital subtraction versus film-screen angiography for detecting acute pulmonary emboli: Evaluation in a porcine model," J. Vascular Interventional Radiol., vol. 8, pp. 1015-1024, 1997.
    • (1997) J. Vascular Interventional Radiol , vol.8 , pp. 1015-1024
    • Schlueter, F.J.1    Zuckerman, D.A.2    Horesh, L.3    Gutierrez, F.R.4    Hicks, M.E.5    Brink, J.A.6
  • 12
    • 0027024759 scopus 로고
    • Digital subtraction angiopulmography in children
    • K. Velkova, "Digital subtraction angiopulmography in children," Folia Medica (Plovdiv), vol. 34, pp. 37-40, 1992.
    • (1992) Folia Medica (Plovdiv) , vol.34 , pp. 37-40
    • Velkova, K.1
  • 13
    • 10744232854 scopus 로고    scopus 로고
    • In vivo real-time microangiography of the liver in mice using synchrotron radiation
    • S. H. Kobayashi et al., "In vivo real-time microangiography of the liver in mice using synchrotron radiation," J. Hepatology, vol. 40, pp. 405-408, 2004.
    • (2004) J. Hepatology , vol.40 , pp. 405-408
    • Kobayashi, S.H.1
  • 14
    • 0036935027 scopus 로고    scopus 로고
    • Cerebral angiography in the rat with mammographic equipment: A simple, cost-effective method for assessing vasospasm in experimental subarachnoid haemorrhage
    • M. Longo, A. Blandino, G. Ascenti, G. K. Ricciardi, F. Granata, and S. Vinci, "Cerebral angiography in the rat with mammographic equipment: A simple, cost-effective method for assessing vasospasm in experimental subarachnoid haemorrhage," Neuroradiology, vol. 44, pp. 689-694, 2002.
    • (2002) Neuroradiology , vol.44 , pp. 689-694
    • Longo, M.1    Blandino, A.2    Ascenti, G.3    Ricciardi, G.K.4    Granata, F.5    Vinci, S.6
  • 15
    • 85047680788 scopus 로고
    • In vivo assessment of left ventricular remodeling after myocardial infarction by digital video contrast angiography in the rat
    • S. Ono, V. Bhargava, L. Mao, G. Hagan, H. A. Rockman, and J. Ross Jr., "In vivo assessment of left ventricular remodeling after myocardial infarction by digital video contrast angiography in the rat," Cardiovascular Res., vol. 28, pp. 349-357, 1994.
    • (1994) Cardiovascular Res , vol.28 , pp. 349-357
    • Ono, S.1    Bhargava, V.2    Mao, L.3    Hagan, G.4    Rockman, H.A.5    Ross Jr., J.6
  • 16
    • 0036558338 scopus 로고    scopus 로고
    • Characterization of a CCD-based digital X-ray imaging system for small-animal studies: Properties of spatial resolution
    • F. Ouandji, E. Potter, W. R. Chen, Y. Li, D. Tang, and H. Liu, "Characterization of a CCD-based digital X-ray imaging system for small-animal studies: Properties of spatial resolution," Appl. Opt., vol. 41, pp. 2420-2427, 2002.
    • (2002) Appl. Opt , vol.41 , pp. 2420-2427
    • Ouandji, F.1    Potter, E.2    Chen, W.R.3    Li, Y.4    Tang, D.5    Liu, H.6
  • 20
    • 0033695419 scopus 로고    scopus 로고
    • Quantitative image analysis of laserinduced choroidal neovascularization in rat
    • J. L. Edelman and M. R. Castro, "Quantitative image analysis of laserinduced choroidal neovascularization in rat," Experimental Eye Res., vol. 71, pp. 523-533, 2000.
    • (2000) Experimental Eye Res , vol.71 , pp. 523-533
    • Edelman, J.L.1    Castro, M.R.2
  • 22
    • 0037151138 scopus 로고    scopus 로고
    • Optimum iodine concentration of contrast material through microcatheters: Hydrodynamic analysis of experimental results
    • T. Yamauchi, S. Furui, A. Harasawa, M. Ishimura, T. Imai, and T. Hayashi, "Optimum iodine concentration of contrast material through microcatheters: Hydrodynamic analysis of experimental results," Phys. Med. Bio., vol. 47, pp. 2511-2523, 2002.
    • (2002) Phys. Med. Bio , vol.47 , pp. 2511-2523
    • Yamauchi, T.1    Furui, S.2    Harasawa, A.3    Ishimura, M.4    Imai, T.5    Hayashi, T.6
  • 23
    • 33750568639 scopus 로고    scopus 로고
    • Optimized radiographic spectra for small animal digital subtraction angiography
    • M. Lin, E. Samei, C. T. Badea, T. T. Yoshizumi, and G. A. Johnson, "Optimized radiographic spectra for small animal digital subtraction angiography," Med. Phys., vol. 33, pp. 4249-4257, 2006.
    • (2006) Med. Phys , vol.33 , pp. 4249-4257
    • Lin, M.1    Samei, E.2    Badea, C.T.3    Yoshizumi, T.T.4    Johnson, G.A.5
  • 24
    • 39749093765 scopus 로고    scopus 로고
    • Functional cardio-pulmonary imaging of the rodent using micro radiography
    • Orlando, FL, Mar. 18-23, presentation
    • M. Lin, C. T. Badea, and G. A. Johnson, "Functional cardio-pulmonary imaging of the rodent using micro radiography," in Acad. Molecular Imaging Annu. Conf., Orlando, FL, Mar. 18-23, 2005, presentation 102.
    • (2005) Acad. Molecular Imaging Annu. Conf , pp. 102
    • Lin, M.1    Badea, C.T.2    Johnson, G.A.3
  • 25
    • 34247571078 scopus 로고    scopus 로고
    • Tumor imaging in small animals with a combined micro-CT/micro-DSA system using iodinated conventional and blood pool contrast agents
    • C. T. Badea, L. W. Hedlund, M. Lin, J. F. Boslego Mackel, and G. A. Johnson, "Tumor imaging in small animals with a combined micro-CT/micro-DSA system using iodinated conventional and blood pool contrast agents," Contrast Media and Molecular Imaging, vol. 1, pp. 153-164, 2006.
    • (2006) Contrast Media and Molecular Imaging , vol.1 , pp. 153-164
    • Badea, C.T.1    Hedlund, L.W.2    Lin, M.3    Boslego Mackel, J.F.4    Johnson, G.A.5
  • 26
    • 34247615131 scopus 로고    scopus 로고
    • Tomographic digital subtraction angiography for lung perfusion estimation in rodent
    • May
    • C. T. Badea, L. W. Hedlund, M. Lin, J. S. Boslego-Mackel, E. Samei, and G. A. Johnson, "Tomographic digital subtraction angiography for lung perfusion estimation in rodent," Med. Phys., vol. 34, no. 5, pp. 1546-1555, May 2007.
    • (2007) Med. Phys , vol.34 , Issue.5 , pp. 1546-1555
    • Badea, C.T.1    Hedlund, L.W.2    Lin, M.3    Boslego-Mackel, J.S.4    Samei, E.5    Johnson, G.A.6
  • 27
    • 38949202992 scopus 로고    scopus 로고
    • Pulmonary perfusion imaging in the rodent lung using dynamic contrast enhanced MRI
    • to be published
    • N. Mistry, J. Pollaro, J. Song, M. Lin, and G. A. Johnson, "Pulmonary perfusion imaging in the rodent lung using dynamic contrast enhanced MRI," Magn. Reson. Med., 2008, to be published.
    • (2008) Magn. Reson. Med
    • Mistry, N.1    Pollaro, J.2    Song, J.3    Lin, M.4    Johnson, G.A.5
  • 28
    • 0013824452 scopus 로고
    • Viscosity, solubility and toxicity in the choice of an angiographic contrast medium
    • H. W. Fischer, "Viscosity, solubility and toxicity in the choice of an angiographic contrast medium," Angiology, vol. 16, pp. 759-766, 1965.
    • (1965) Angiology , vol.16 , pp. 759-766
    • Fischer, H.W.1
  • 30
    • 11244304503 scopus 로고    scopus 로고
    • Micro-CT with respiratory and cardiac gating
    • C. T. Badea, L. W. Hedlund, and G. A. Johnson, "Micro-CT with respiratory and cardiac gating," Med. Phys., vol. 31, pp. 3324-3329, 2004.
    • (2004) Med. Phys , vol.31 , pp. 3324-3329
    • Badea, C.T.1    Hedlund, L.W.2    Johnson, G.A.3
  • 31
    • 0021280694 scopus 로고
    • Digital subtraction angiography: Fundamental noise characteristics
    • S. Balter, D. Ergun, E. Tscholl, F. Buchmann, and L. Verhoeven, "Digital subtraction angiography: Fundamental noise characteristics," Radiology, vol. 152, pp. 195-198, 1984.
    • (1984) Radiology , vol.152 , pp. 195-198
    • Balter, S.1    Ergun, D.2    Tscholl, E.3    Buchmann, F.4    Verhoeven, L.5
  • 32
    • 35448999106 scopus 로고    scopus 로고
    • Physics of Medical Imaging, 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins
    • J. Bushberg, J. A. Seibert, E. M. J. Leidholdt, and J. M. Boone, The Essential Physics of Medical Imaging, 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins, 2002.
    • (2002) The Essential
    • Bushberg, J.1    Seibert, J.A.2    Leidholdt, E.M.J.3    Boone, J.M.4
  • 33
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • L. Ostergaard, R. M. Weisskoff, D. A. Chesler, C. Gyldensted, and B. R. Rosen, "High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis," Magn. Reson. Med., vol. 36, pp. 715-725, 1996.
    • (1996) Magn. Reson. Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 34
    • 0037225618 scopus 로고    scopus 로고
    • Measurement of regional lung function in rats using hyperpolarized 3Helium dynamic MRI
    • B. T. Chen, A. C. S. Brau, and G. A. Johnson, "Measurement of regional lung function in rats using hyperpolarized 3Helium dynamic MRI," Magn. Reson. Med., vol. 49, pp. 78-88, 2003.
    • (2003) Magn. Reson. Med , vol.49 , pp. 78-88
    • Chen, B.T.1    Brau, A.C.S.2    Johnson, G.A.3
  • 35
    • 12144266998 scopus 로고    scopus 로고
    • Ventilation- synchronous MR microscopy of pulmonary structure and ventilation in mice
    • B. T. Chen, A. T. Yordanov, and G. A. Johnson, "Ventilation- synchronous MR microscopy of pulmonary structure and ventilation in mice," Magn. Reson. Med., vol. 53, pp. 69-75, 2005.
    • (2005) Magn. Reson. Med , vol.53 , pp. 69-75
    • Chen, B.T.1    Yordanov, A.T.2    Johnson, G.A.3
  • 38
    • 0021961581 scopus 로고
    • Blood volume in the rat
    • H. Lee and M. Blaufox, "Blood volume in the rat," J. Nucl. Med., vol. 26, pp. 72-76, 1985.
    • (1985) J. Nucl. Med , vol.26 , pp. 72-76
    • Lee, H.1    Blaufox, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.