메뉴 건너뛰기




Volumn 8668, Issue , 2013, Pages

High energy X-ray phase-contrast imaging using glancing angle grating interferometers

Author keywords

Talbot lau interferometer; X ray phase contrast

Indexed keywords

CLINICAL APPLICATION; FRINGE CONTRASTS; GLANCING INCIDENCE; GRATING INTERFEROMETERS; HIGH ENERGY X-RAYS; INTERFEROMETER DESIGNS; TALBOT-LAU INTERFEROMETER; X RAY PHASE CONTRAST;

EID: 84878334247     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.2007930     Document Type: Conference Paper
Times cited : (6)

References (15)
  • 1
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with lowbrilliance
    • Pfeiffer F., Weitkamp T., Bunk O. and David C, "Phase retrieval and differential phase-contrast imaging with lowbrilliance". X-ray sourcesNature Physics 2, 258 (2006);.
    • (2006) X-ray SourcesNature Physics , vol.2 , pp. 258
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 3
    • 84864246621 scopus 로고    scopus 로고
    • Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta neq(K)
    • Tang X., Yang Y., and Tang S., "Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)", Med. Phys. 39, 4467 (2012).
    • (2012) Med. Phys , vol.39 , pp. 4467
    • Tang, X.1    Yang, Y.2    Tang, S.3
  • 4
    • 84861163274 scopus 로고    scopus 로고
    • X-ray vector radiography for bone micro-architecture diagnostics
    • Potdevin G., et al., "X-ray vector radiography for bone micro-architecture diagnostics", Phys. Med. Biol. 57 3451(2012).
    • (2012) Phys. Med. Biol , vol.57 , pp. 3451
    • Potdevin, G.1
  • 5
    • 80052071420 scopus 로고    scopus 로고
    • Talbot phase-contrast x-ray imaging for the small joints of the hand
    • Stutman D., Beck T.J., Carrino J.A., and Bingham C.O., "Talbot phase-contrast x-ray imaging for the small joints of the hand", Phys. Med. Biol. 56 5697(2011).
    • (2011) Phys. Med. Biol , vol.56 , pp. 5697
    • Stutman, D.1    Beck, T.J.2    Carrino, J.A.3    Bingham, C.O.4
  • 6
    • 79551654418 scopus 로고    scopus 로고
    • Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography
    • Chen G-H., Zambelli J., Li K., Bevins N., and Qi Z., "Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography", Med. Phys. 38, 584 (2011).
    • (2011) Med. Phys , vol.38 , pp. 584
    • Chen, G.-H.1    Zambelli, J.2    Li, K.3    Bevins, N.4    Qi, Z.5
  • 8
    • 84865858246 scopus 로고    scopus 로고
    • Glancing angle talbot-lau grating interferometers for phase contrast imaging at high xray energy
    • Stutman D., Finkenthal M., Glancing angle Talbot-Lau grating interferometers for phase contrast imaging at high xray energy", Appl. Phys. Lett. 101, 091108 (2012).
    • (2012) Appl. Phys. Lett , vol.101 , pp. 091108
    • Stutman, D.1    Finkenthal, M.2
  • 9
    • 84878331452 scopus 로고    scopus 로고
    • http://www.micro-works.de/.
  • 10
    • 37349109656 scopus 로고    scopus 로고
    • Cartilage thickness:factors influencing multidetector CT measurements in a phantom study
    • Anderson A.E., Ellis B J, Peters C L, Weiss J A, "Cartilage Thickness:Factors Influencing Multidetector CT Measurements in a Phantom Study", Radiology 246, 133 (2008).
    • (2008) Radiology , vol.246 , pp. 133
    • Anderson, A.E.1    Ellis, B.J.2    Peters, C.L.3    Weiss, J.A.4
  • 11
    • 84873276599 scopus 로고    scopus 로고
    • Feasibility of differential phase contrast ct for whole body imaging
    • Li K., Bevins N B, Zambelli J N, and Chen G-H, "Feasibility of differential phase contrast CT for whole body imaging", AIP Conf. Proc. 1466, 175 (2012).
    • (2012) AIP Conf. Proc. , vol.1466 , pp. 175
    • Li, K.1    Bevins, N.B.2    Zambelli, J.N.3    Chen, G.-H.4
  • 13
    • 84873258530 scopus 로고    scopus 로고
    • X-ray talbot-lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation
    • Margie P. Olbinado, Sébastien Harasse, Wataru Yashiro, and Atsushi Momose"X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation", AIP Conf. Proc. 1466, 266 (2012).
    • (2012) AIP Conf. Proc , vol.1466 , pp. 266
    • Olbinado, M.P.1    Harasse, S.2    Yashiro, W.3    Momose, A.4
  • 15
    • 84855446783 scopus 로고    scopus 로고
    • Multicontrast x-ray computed tomography imaging using talbot-lau interferometry without phase stepping
    • Nicholas Bevins, Joseph Zambelli, Ke Li, and Zhihua Qi, "Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping", Med. Phys. 39, 424(2012).
    • (2012) Med. Phys , vol.39 , pp. 424
    • Bevins, N.1    Zambelli, J.2    Li, K.3    Qi, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.