-
1
-
-
51849131434
-
In vivo small-animal imaging using micro-CT and digital subtraction angiography
-
10.1088/0031-9155/53/19/R01
-
C. T. Badea, In vivo small-animal imaging using micro-CT and digital subtraction angiography., Phys. Med. Biol. 53 (19), R319-R350 (2008). 10.1088/0031-9155/53/19/R01
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.19
-
-
Badea, C.T.1
-
2
-
-
0035996436
-
Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
-
DOI 10.1118/1.1487861
-
M. Kachelriess, Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart., Med. Phys. 29 (7), 1489-1504 (2002). 10.1118/1.1487861 (Pubitemid 34774581)
-
(2002)
Medical Physics
, vol.29
, Issue.7
, pp. 1489-1503
-
-
Kachelriess, M.1
Sennst, D.-A.2
Maxlmoser, W.3
Kalender, W.A.4
-
3
-
-
38449107364
-
Retrospective motion gating in small animal CT of mice and rats
-
DOI 10.1097/RLI.0b013e318070dcad, PII 0000442420071000000007
-
S. H. Bartling, Retrospective motion gating in small animal CT of mice and rats., Invest. Radiol. 42 (10), 704-714 (2007). 10.1097/RLI.0b013e318070dcad (Pubitemid 351325903)
-
(2007)
Investigative Radiology
, vol.42
, Issue.10
, pp. 704-714
-
-
Bartling, S.H.1
Stiller, W.2
Grasruck, M.3
Schmidt, B.4
Peschke, P.5
Semmler, W.6
Kiessling, F.7
-
4
-
-
26944469103
-
4-D micro-CT of the mouse heart
-
C. T. Badea, 4-D micro-CT of the mouse heart., Mol. Imaging 4 (2), 110-116 (2005). (Pubitemid 43143798)
-
(2005)
Molecular Imaging
, vol.4
, Issue.2
, pp. 110-116
-
-
Badea, C.T.1
Fubara, B.2
Hedlund, L.W.3
Johnson, G.A.4
-
5
-
-
33846189786
-
Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice
-
DOI 10.1097/01.rli.0000251572.56139.a3, PII 0000442420070200000003
-
M. Drangova, Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice., Invest. Radiol. 42 (2), 85-94 (2007). 10.1097/01.rli.0000251572.56139.a3 (Pubitemid 46104888)
-
(2007)
Investigative Radiology
, vol.42
, Issue.2
, pp. 85-94
-
-
Drangova, M.1
Ford, N.L.2
Detombe, S.A.3
Wheatley, A.R.4
Holdsworth, D.W.5
-
6
-
-
35648981849
-
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
-
DOI 10.1118/1.2795830
-
J. Song, Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT., Med. Phys. 34, 4476-4483 (2007). 10.1118/1.2795830 (Pubitemid 350029668)
-
(2007)
Medical Physics
, vol.34
, Issue.11
, pp. 4476-4483
-
-
Song, J.1
Liu, Q.H.2
Johnson, G.A.3
Badea, C.T.4
-
7
-
-
38849164794
-
Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
-
DOI 10.1118/1.2836423
-
G. H. Chen, J. Tang, and S. H. Leng, Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets., Med. Phys. 35 (2), 660-663 (2008). 10.1118/1.2836423 (Pubitemid 351190885)
-
(2008)
Medical Physics
, vol.35
, Issue.2
, pp. 660-663
-
-
Chen, G.-H.1
Tang, J.2
Leng, S.3
-
8
-
-
79952162862
-
Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals
-
10.1118/1.3551993
-
S. Sawall, Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals., Med. Phys. 38 (3), 1416-1424 (2011). 10.1118/1.3551993
-
(2011)
Med. Phys.
, vol.38
, Issue.3
, pp. 1416-1424
-
-
Sawall, S.1
-
9
-
-
0017108614
-
Energy-selective reconstructions in x-ray computerized tomography
-
10.1088/0031-9155/21/5/002
-
R. E. Alvarez and A. Macovski, Energy-selective reconstructions in x-ray computerized tomography., Phys. Med. Biol. 21 (5), 733-744 (1976). 10.1088/0031-9155/21/5/002
-
(1976)
Phys. Med. Biol.
, vol.21
, Issue.5
, pp. 733-744
-
-
Alvarez, R.E.1
MacOvski, A.2
-
10
-
-
76149112304
-
Dual-energy attenuation coefficient decomposition with differential filtration and application to a micro-CT scanner
-
10.1088/0031-9155/55/4/016
-
R. Taschereau, R. W. Silverman, and A. F. Chatziioannou, Dual-energy attenuation coefficient decomposition with differential filtration and application to a micro-CT scanner., Phys. Med. Biology 55 (4), 1141-1155 (2010). 10.1088/0031-9155/55/4/016
-
(2010)
Phys. Med. Biology
, vol.55
, Issue.4
, pp. 1141-1155
-
-
Taschereau, R.1
Silverman, R.W.2
Chatziioannou, A.F.3
-
11
-
-
70449418028
-
Model-based image reconstruction for dual-energy x-ray CT with fast Kvp switching
-
(IEEE, New York)
-
W. Huh and J. A. Fessler, Model-based image reconstruction for dual-energy x-ray CT with fast Kvp switching., IEEE International Symposium on Biomedical Imaging (IEEE, New York, 2009), pp. 326-329.
-
(2009)
IEEE International Symposium on Biomedical Imaging
, pp. 326-329
-
-
Huh, W.1
Fessler, J.A.2
-
12
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
DOI 10.1007/s00330-005-2919-2
-
T. G. Flohr, First performance evaluation of a dual-source CT (DSCT) system., Eur. Radiol. 16 (2), 256-268 (2006). 10.1007/s00330-005-2919-2 (Pubitemid 43149624)
-
(2006)
European Radiology
, vol.16
, Issue.2
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
Petersilka, M.4
Gruber, K.5
Suss, C.6
Grasruck, M.7
Stierstorfer, K.8
Krauss, B.9
Raupach, R.10
Primak, A.N.11
Kuttner, A.12
Achenbach, S.13
Becker, C.14
Kopp, A.15
Ohnesorge, B.M.16
-
13
-
-
48349104955
-
SNR performance comparison of dual-layer detector and dual-kVp spectral CT
-
(IEEE Medical Imaging Conference Record, Honolulu, HI)
-
B. J. Heismann and S. Wirth, SNR performance comparison of dual-layer detector and dual-kVp spectral CT., Nuclear Science Symposium Conference Record (IEEE Medical Imaging Conference Record, pp. 3280-3822, Honolulu, HI, 2007).
-
(2007)
Nuclear Science Symposium Conference Record
, pp. 3280-3822
-
-
Heismann, B.J.1
Wirth, S.2
-
14
-
-
54949084297
-
Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition
-
10.1118/1.2987668
-
P. V. Granton, Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition., Med. Phys. 35 (11), 5030-5042 (2008). 10.1118/1.2987668
-
(2008)
Med. Phys.
, vol.35
, Issue.11
, pp. 5030-5042
-
-
Granton, P.V.1
-
15
-
-
54349089179
-
Development of novel statistical reconstruction algorithms for poly-energetic X-ray computed tomography
-
10.1016/j.cmpb.2008.04.002
-
H. S. Chueh, Development of novel statistical reconstruction algorithms for poly-energetic X-ray computed tomography., Comput. Methods Programs Biomed. 92 (3), 289-293 (2008). 10.1016/j.cmpb.2008.04.002
-
(2008)
Comput. Methods Programs Biomed.
, vol.92
, Issue.3
, pp. 289-293
-
-
Chueh, H.S.1
-
16
-
-
0036462553
-
Statistical image reconstruction for polyenergetic X-ray computed tomography
-
DOI 10.1109/42.993128, PII S0278006202029361
-
I. A. Elbakri and J. A. Fessler, Statistical image reconstruction for polyenergetic x-ray computed tomography., IEEE Trans. Med. Imaging 21 (2), 89-99 (2002). 10.1109/42.993128 (Pubitemid 34466423)
-
(2002)
IEEE Transactions on Medical Imaging
, vol.21
, Issue.2
, pp. 89-99
-
-
Elbakri, I.A.1
Fessler, J.A.2
-
17
-
-
0033181297
-
Monotonic algorithms for transmission tomography
-
DOI 10.1109/42.802758
-
H. Erdogan and J. A. Fessler, Monotonic algorithms for transmission tomography., IEEE Trans. Med. Imaging 18 (9), 801-814 (1999). 10.1109/42.802758 (Pubitemid 30519199)
-
(1999)
IEEE Transactions on Medical Imaging
, vol.18
, Issue.9
, pp. 801-814
-
-
Erdogan, H.1
Fessler, J.A.2
-
18
-
-
0021445363
-
Practical cone-beam algorithm
-
10.1364/JOSAA.1.000612
-
L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical cone-beam algorithm., J. Opt. Soc. Am. A Opt. Image Sci. Vis 1 (6), 612-619 (1984). 10.1364/JOSAA.1.000612
-
(1984)
J. Opt. Soc. Am. A Opt. Image Sci. Vis
, vol.1
, Issue.6
, pp. 612-619
-
-
Feldkamp, L.A.1
Davis, L.C.2
Kress, J.W.3
-
20
-
-
84864708656
-
3rd ed
-
(Cambridge University Press, Cambridge, England)
-
W. H. Press Numerical Recipes, 3rd ed.. (Cambridge University Press, Cambridge, England, 2007).
-
(2007)
Numerical Recipes
-
-
Press, W.H.1
-
21
-
-
78650136425
-
An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach
-
10.1118/1.3495818
-
C. Neukirchen, M. Giordano, and S. Wiesner, An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach., Med. Phys. 37 (12), 6125-6141 (2010). 10.1118/1.3495818
-
(2010)
Med. Phys.
, vol.37
, Issue.12
, pp. 6125-6141
-
-
Neukirchen, C.1
Giordano, M.2
Wiesner, S.3
-
22
-
-
0021344602
-
Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
-
A. H. Andersen and A. C. Kak, Simultaneous algebraic reconstruction technique (SART): A superior implementation of the ART algorithm., Ultrason. Imaging 6 (1), 81-94 (1984). 10.1016/0161-7346(84)90008-7 (Pubitemid 14139189)
-
(1984)
Ultrasonic Imaging
, vol.6
, Issue.1
, pp. 81-94
-
-
Andersen, A.H.1
Kak, A.C.2
-
23
-
-
0034178294
-
Unmatched projectorbackprojector pairs in an iterative reconstruction algorithm
-
10.1109/42.870265
-
G. S. L. Zeng and G. T. Gullberg, Unmatched projectorbackprojector pairs in an iterative reconstruction algorithm., IEEE Trans. Med. Imaging 19 (5), 548-555 (2000). 10.1109/42.870265
-
(2000)
IEEE Trans. Med. Imaging
, vol.19
, Issue.5
, pp. 548-555
-
-
Zeng, G.S.L.1
Gullberg, G.T.2
-
24
-
-
9244249165
-
Spektr: A computational tool for x-ray spectral analysis and imaging system optimization
-
DOI 10.1118/1.1758350
-
J. H. Siewerdsen, Spektr: A computational tool for x-ray spectral analysis and imaging system optimization., Med. Phys. 31 (11), 3057-3067 (2004). 10.1118/1.1758350 (Pubitemid 39552696)
-
(2004)
Medical Physics
, vol.31
, Issue.11
, pp. 3057-3067
-
-
Siewerdsen, J.H.1
Waese, A.M.2
Moseley, D.J.3
Richard, S.4
Jaffray, D.A.5
-
25
-
-
0030657556
-
An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
-
DOI 10.1118/1.597953
-
J. M. Boone and J. A. Seibert, Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV., Med. Phys. 24 (11), 1661-1670 (1997). 10.1118/1.597953 (Pubitemid 27495900)
-
(1997)
Medical Physics
, vol.24
, Issue.11
, pp. 1661-1670
-
-
Boone, J.M.1
Seibert, J.A.2
-
26
-
-
28744450169
-
A review, bibliography, and tabulation of K, L, and higher atomic shell x-ray-fluorescence yields
-
10.1063/1.555955
-
J. H. Hubbell, A review, bibliography, and tabulation of K, L, and higher atomic shell x-ray-fluorescence yields., J. Phys. Chem. Ref. Data 23 (2), 339-364 (1994). 10.1063/1.555955
-
(1994)
J. Phys. Chem. Ref. Data
, vol.23
, Issue.2
, pp. 339-364
-
-
Hubbell, J.H.1
-
27
-
-
70349694122
-
Quantitative image-based spectral reconstruction for computed tomography
-
10.1118/1.3213534
-
B. Heismann and M. Balda, Quantitative image-based spectral reconstruction for computed tomography., Med. Phys. 36 (10), 4471-4485 (2009). 10.1118/1.3213534
-
(2009)
Med. Phys.
, vol.36
, Issue.10
, pp. 4471-4485
-
-
Heismann, B.1
Balda, M.2
-
28
-
-
84860382310
-
A spectral calibration technique for x-ray CT
-
10.1117/12.911532
-
S. M. Johnston, G. A. Johnson, and C. T. Badea, A spectral calibration technique for x-ray CT., Proc. SPIE 8313, 831333 (2012). 10.1117/12.911532
-
(2012)
Proc. SPIE
, vol.8313
, pp. 831333
-
-
Johnston, S.M.1
Johnson, G.A.2
Badea, C.T.3
-
29
-
-
2942654916
-
Development of a 4-digital mouse phantom for molecular imaging research
-
DOI 10.1016/j.mibio.2004.03.002, PII S1536163204002173
-
W. P. Segars, Development of a 4-D digital mouse phantom for molecular imaging research., Mol. Imaging Biol. 6 (3), 149-159 (2004). 10.1016/j.mibio.2004.03.002 (Pubitemid 38771978)
-
(2004)
Molecular Imaging and Biology
, vol.6
, Issue.3
, pp. 149-159
-
-
Segars, W.P.1
Tsui, B.M.W.2
Frey, E.C.3
Johnson, G.A.4
Berr, S.S.5
-
30
-
-
43149102533
-
A dual micro-CT system for small animal imaging
-
DOI 10.1117/12.772303, Medical Imaging 2008 - Physics of Medical Imaging
-
C. T. Badea, A dual micro-CT system for small animal imaging., Proc. SPIE 6913, 691342 (2008). 10.1117/12.772303 (Pubitemid 351644085)
-
(2008)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.6913
, pp. 691342
-
-
Badea, C.T.1
Johnston, S.2
Johnson, B.3
Lin, M.4
Hedlund, L.W.5
Johnson, G.A.6
-
31
-
-
33846246695
-
An optimal radial profile order based on the golden ratio for time-resolved MRI
-
DOI 10.1109/TMI.2006.885337
-
S. Winkelmann, An optimal radial prole order based on the golden ratio for time-resolved MRI., IEEE Trans. Med. Imaging 26 (1), 68-76 (2007). 10.1109/TMI.2006.885337 (Pubitemid 46096351)
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.1
, pp. 68-76
-
-
Winkelmann, S.1
Schaeffter, T.2
Koehler, T.3
Eggers, H.4
Doessel, O.5
-
32
-
-
78649944912
-
Evaluation of tumor microenvironment in an Animal model using a nanoparticle contrast agent in computed tomography imaging
-
10.1016/j.acra.2010.09.003
-
K. B. Ghaghada, Evaluation of tumor microenvironment in an Animal model using a nanoparticle contrast agent in computed tomography imaging., Acad. Radiol. 18 (1), 20-30 (2011). 10.1016/j.acra.2010.09.003
-
(2011)
Acad. Radiol.
, vol.18
, Issue.1
, pp. 20-30
-
-
Ghaghada, K.B.1
-
33
-
-
84875568786
-
-
www.civm.duhs.duke.edu/medphy5dct/.
-
-
-
-
34
-
-
31044442530
-
Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
-
DOI 10.1118/1.2148333
-
R. Taschereau, P. L. Chow, and A. F. Chatziioannou, Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom., Med. Phys. 33 (1), 216-224 (2006). 10.1118/1.2148333 (Pubitemid 43121051)
-
(2006)
Medical Physics
, vol.33
, Issue.1
, pp. 216-224
-
-
Taschereau, R.1
Chow, P.L.2
Chatziioannou, A.F.3
-
35
-
-
73649083320
-
Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution
-
10.1118/1.3264619
-
C. T. Badea, Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution., Med. Phys. 37 (1), 54-62 (2010). 10.1118/1.3264619
-
(2010)
Med. Phys.
, vol.37
, Issue.1
, pp. 54-62
-
-
Badea, C.T.1
-
36
-
-
0033044150
-
Gadolinium as a CT contrast agent: Assessment in a porcine model
-
D. S. Gierada and T. B. Kyongtae, Gadolinium as a CT contrast agent: Assessment in a porcine model., Radiology 210 (3), 829-834 (1999). (Pubitemid 29124048)
-
(1999)
Radiology
, vol.210
, Issue.3
, pp. 829-834
-
-
Gierada, D.S.1
Bae, K.2
-
37
-
-
79955750041
-
Dual-energy micro-CT imaging for differentiation of iodine- and gold-based nanoparticles temporal and spectral reconstruction algorithms for x-ray CT
-
10.1117/12.878043
-
C. T. Badea, Dual-energy micro-CT imaging for differentiation of iodine- and gold-based nanoparticles temporal and spectral reconstruction algorithms for x-ray CT., Proc. SPIE 7961, 79611X (2011). 10.1117/12.878043
-
(2011)
Proc. SPIE
, vol.7961
-
-
Badea, C.T.1
|